Loading...
939 Amberjack Ln MCRS21-0014 1 of 2 solar PV roof panels permitOWNER:ADDRESS:CITY:STATE:ZIP: HAMPTON MARY E ET AL 939 AMBERJACK LA ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: MOMENTUM SOLAR 6210 HOFFNER AVE ORLANDO FL 32822 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171175 0000 ROYAL PALMS UNIT 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 939 AMBERJACK LN MECHANICAL RESIDENTIAL OTHER SOLAR PHOTOVOLTAIC ROOF PANELS $30196.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $139.03 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 2/15/2022 PERMIT NUMBER MCRS21-0014 ISSUED: 2/15/2022 EXPIRES: 8/14/2022 MECHANICAL RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 2 of 2Issued Date: 2/15/2022 PERMIT NUMBER MCRS21-0014 ISSUED: 2/15/2022 EXPIRES: 8/14/2022 MECHANICAL RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION Permit Number: MCRS21-0014 Site Address: 939 AMBERJACK LN City, State Zip Code: ATLANTIC BEACH, FL 32233 Applied: 12/22/2021 Approved: Issued: Parent Permit: Parent Project: Applicant: <NONE> Owner: HAMPTON MARY E ET AL Contractor: <NONE> Description: SOLAR PHOTOVOLTAIC ROOF PANELS Finaled: Status: RECEIVED Details: LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: AUTO 12/22/2021 12/22/2021 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 5 ATTACHMENTS from JMosquera@momentumsolar.com 12/22/2021 1/20/2022 1/10/2022 BUILDING Building DENIED Notes: Correction Comments: 1. The space provided on the building application labeled RE# was left blank, making the application incomplete. Please resubmit the application completed. 2. The spaces on the building application for the contact information for Architects and Engineers for this project was left blank. Submitted information has come from both of those entities. Please record this information on the building permit and resubmit the application completed. 3. The Architectural letter from Daniel W. Dunzik was digitally locked and unable to receive and plan review stamps from this building department plan reviewer. Please resubmit the documents Adobe Acrobat friendly and able to receive plan review stamps. 4. Resubmittals may generate other review comments. 5. The link to the revision/correction form is : http://coab.us/DocumentCenter/View/10495/Revision-Request-Correction-to-Comments-Route-Sheet- v20181017?bidId= 6. The email address to send resubmittals is : Building-dept@coab.us Printed: Friday, 21 January, 2022 1 of 1 Permit Reviews City of Atlantic Beach Revision Request lCorrection to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL32233 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Phone: (904) 247-5826 Email:Buildine-@coab.us pERMtr#: SOLR21-0009 l_l Revision to lssued Permit OR Corrections to Comments sils.0210412022 Project Address Christopher Tanner Contractor/Contact Name:[t/lomentum Solar Contact phone: $21) 247-6073 s*r;1. fl permits@momentumsolar.com Description of Proposed Revision / Corrections: Unlocked Eng Letter I Cameron Christensen affirm the revision/correction to comments is inclusive of the proposed changes (printed name) a add additional square footage to original submittal? be added: a-\&ill proposed revision/corrections add additional increase in building value to original submittal? l"Jr.lol_l*Y",(additionalincreaseinbuildingvalue:S-)1Cont,,.to,mustsignifincreaseinvaluation) *Signatu re of Contractor/Agent: tr Rpproved I oenied (Office Use Only) E ruot Applicable to Department Permit Fee Due ( Revision/Plan Review Comm Department Review Required : Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services Reviewed By Date Updated 10/17/18 raAt Corrections Made to Electrical Application MCRS21-0014 updoted 10/9178 **ALL INFORMATION HIGHTIGHTED IN GRAY IS REQUIRED. Job Address: 939 AMBERJACK LN ATLANTIC BEACH, FL 32233 Permit Number: SOLR21-0009 30-60 17-2S-29E ROYAL PALMS UNIT 1 LOT 21BLK4 RE# 171175-AAOO Valuation of Work (Replacement Cost) S 30,196.80 Heated/Cooled SF _ Non- Heated,/Cooled_ r Classof Work: nNew trAddition lAlteration DRepair !Move trDemo trPool DWindow/Door r Use of existinglproposed structure(s): ICommercial trResidential o lf an existing structure, is a fire sprinkler system installed?: lYes trNo Florida Product Approval for multiple products use product approval form a ++ ProperW Owner lnformation Name ChristopherTanner Address 939 AMBERJACK LN City ATLANTIC BEACH State FL zip 32233 phone 321-247-6073 E-Mail fl permits@momentumsolar. com Describe in detail the type of work to be performed lnstallation of photo voltaic solar panels on rooftop Name of Company Momentum Solar Qualifying Agent Office Phone 321-2474073 State Certification/Registratio n # cvcs7036 Architect Name & Phone # Daniel Dunzik 908-872-3664 Job Site Contact Number 321-2474073 Englneer''s Name & Phone 6 Mina Makar 551-689-5068 Workers Compe nsation tnsurer Zurich American lnsurance Company OR Exempt n Expiration Date _ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANK5, and AIR CONDITIONERS, etc. NOTICE: ln addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERW. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECOft I NG;YOU R NOTTCE OF COMM ENCEMENT./ff\,r^lq (Signature of Owner or Agent){Signature of Contractor) Signed and sworn to (or affirmed) before me this 4 day of Signed and sworn to (or affirmed) before me this - day of Februarv . 2022 Februarv ure of rv) SAI"6ADO [ ] Personally Known OR ffi Produced ldentification Commisslon # GG 572215 ErPiros JulY 2'1, 2C24 Bcnded thru Budget Notary Servic€a [Xl Personally Known OR [ ] Produced ldentification KRISTINA SALGADO Commlssion # GG 972215 Expires JulY 21, 2024 Bonded Ihru BudgetNotary Seryices .6{Y Pgs #*;Type of ldentification:Type of ldentification . xRY P(tp, ={. ^ 2- *#ss Building Permit Application City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL32233 Phone: (904) 247 -5826 Email: Buildins-Dept@coab.us Legal Description ownerorAgent(lfAgent,PowerofAttorneyorAgencyLetterRequired) Contractor lnformation Cameron Christensen Address 6210 Hoffner Ave Ste 100 City Orlando State FL Zip 32822 E-Mail flpermits@momentumsolar.com The Enphase Encharge 10™ all-in-one AC-coupled storage system is reliable, smart, simple, and safe. It is comprised of three base Encharge 3™ storage units, has a total usable energy capacity of 10.08kWh and twelve embedded grid-forming microinverters with 3.84kW power rating. It provides backup capability and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. Enphase Encharge 10 To learn more about Enphase offerings, visit enphase.com Data SheetEnphase Storage System Reliable • Proven high reliability IQ Series Microinverters • Ten-year limited warranty • Three independent Encharge storage base units • Twelve embedded IQ 8X-BAT Microinverters • Passive cooling (no moving parts/fans) Smart • Grid-forming capability for backup operation • Remote software and firmware upgrade • Mobile app-based monitoring and control • Support for self consumption • Utility time of use (TOU) optimization Simple • Fully integrated AC battery system • Quick and easy plug-and-play installation • Interconnects with standard household AC wiring Safe • Cells safety tested • Lithium iron phosphate (LFP) chemistry for maximum safety and longevity PRELIMINARY P R E L I MMCRS21-0014 To learn more about Enphase offerings, visit enphase.com © 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Encharge 10, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-01-11 MODEL NUMBER ENCHARGE-10-1P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery management unit (BMU). Includes: - Three Encharge 3.36kWh base units (B3-A01-US001-1-3) - One Encharge 10 cover kit with cover, wall mounting bracket, watertight conduit hubs, and interconnect kit for wiring between batteries (B10-C-1050-O) ACCESSORIES B10-W-AWG08-0700-O Interconnect kit for wiring between the three Encharge base units in the Encharge 10 OUTPUT (AC)@ 240 VAC¹ Rated (continuous) output power²3.84 kVA Peak output power 5.7 kVA (10 seconds) Nominal voltage / range 240 / 211 — 264 VAC Nominal frequency / range 60 / 57 — 61 Hz Rated output current 16 A Power factor (adjustable)0.85 leading ... 0.85 lagging Maximum units per 20 A branch circuit 1 unit (single phase) Interconnection single-phase Round trip efficiency²89% BATTERY Total capacity 10.5 kWh Usable capacity 10.08 kWh Round trip efficiency 96% Maximum DC voltage 73.5 V Ambient operating temperature range -15º C to 55º C (5º F to 131º F) non-condensing Optimum operating temperature range 0º C to 30º C (32º F to 86º F) Chemistry Lithium iron phosphate (LFP) MECHANICAL DATA Dimensions (WxHxD)1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) Weight Three individual 44.2 kg (97.4 lbs) base units plus 21.1 kg (48.7 lbs) cover and mounting bracket; total 154.7 kg (341 lbs) Enclosure Outdoor – NEMA 3R Cooling Natural convection – No fans Altitude Up to 2500 meters (8200 feet) Mounting Wall mount FEATURES AND COMPLIANCE Compatibility Compatible with grid-tied PV systems. Compatible with Enphase IQ Series Micros, Enphase Enpower, and Enphase IQ Envoy for backup operation. Communication Wireless 2.4 GHz and 915 MHz Services Backup, self-consumption, TOU, Demand Charge, NEM Integrity Monitoring Enlighten Manager and MyEnlighten monitoring options; API integration Compliance (pending)UL 1741SA (inverters), UL 1973, UL 9540, UN 38.3, UL 9540A, UL 62109-1 (inverters), IEC 62109-2 (inverters), CAN/CSA C22.2 No. 107.1-16 (inverters), NEMA Type 3R, AC156, UL1998, 47 CFR, Part 15, Class B, ICES 003 LIMITED WARRANTY Limited Warranty3 >70% capacity, up to 10 years or 4000 cycles 1. Supported in backup/off grid operations2. AC to Battery to AC at 50% power rating.3. Whichever occurs first. Restrictions apply. Enphase Encharge 10 PRELIMINARY P R E L I M The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data SheetEnphase MicroinvertersRegion: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-01-06 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 %97.6 %97.5 %97.3 % CEC weighted efficiency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (HxWxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters ® www.roof-tech.us info@roof-tech.us RT-MINI Self-flashing base for asphalt & metal roof-top PV mounting systems Dual bolt design: M8 or 5/16” for L-Foot & 1/4” for EMC 1/4” Hex Bolt upper channel Easy tapping screw guide M8 or 5/16” Hex Bolt bottom channel Flat lip for PV Cable clips RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Call Now for more details 858-935-6064 ICC ESR 3575 RT-MINI Flexible Flashing certified by the International Code Council (ICC) Components RT2-00-MINIBK MINI base : 20 ea. Screw : 40 ea. Extra RT-Butyl : 10 ea. RT-Butyl is Roof Tech s flexible flashing used in 700,000 residential PV systems for the last 24 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. ICC ESR-3575 ASTM2140 testing UV testing (7500 hrs.) www.roof-tech.us info@roof-tech.us 10620 Treena Street, Suite 230, San Diego, CA 92131 858.935.6064 Roof Tech Inc. Flexible Flashing 100% Waterproof Metal Flashing Retrofit Shedding water? Ra"er installa#on Deck installa#on ’ P.E. Stamped Letters available at www.roof-tech.us/support PAT : PENDING Dimensions in (mm) Optional item 5 x 60mm Mounting screw (RT2-04-SD5-60) : 100 ea./Bag 5/16” Hex bolt, washer & nut set (RT-04-BN30SL-US) : 100 ea./Bag RT-Butyl (RT2-04-BUTYLT) : 10 ea./Box Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood)4 ( 100 )3/4 ( 19 )3 1/2 ( 90 ) 2 ( 50 ) Rev. 03-2020