Loading...
363 Atlantic Blvd Unit 2, 3 Valhalla Tap Room interior build out permit 2 of 5RELEASED FOR CONSTRUCTION: 14 DECEMBER 2021 PERMIT SET 1'-0"4'-0"1'-6"5'-0"4'-0"3'-0"5'-0"3'-6"1'-10" 3'-6"4'-6" PER FBC-A 2017 FIGURE 404.2.4.1 (A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE (C) FRONT APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND A LATCH (D) HINGE APPROACH, PULL SIDE (F) HINGE APPROACH, PUSH SIDE (E) HINGE APPROACH, PULL SIDE 4'-0"(G) HINGE APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND A LATCH 1'-10" 2'-0"4'-0"(H) LATCH APPROACH, PULL SIDE 2'-0"4'-6"(I) LATCH APPROACH, PULL SIDE, DOOR PROVIDED WITH CLOSER 3'-6"2'-0" (J) LATCH APPROACH, PUSH SIDE 4'-0"2'-0" (K) LATCH APPROACH, PUSH SIDE, DOOR PROVIDED WITH CLOSER SCALE: 1/4" = 1'-0" 38. THESE DOCUMENTS ARE PREPARED FOR THE USE OF THE GENERAL CONTRACTOR AND HIS SUBCONTRACTORS AND IN NO WAY, EITHER IN WHOLE OR IN PART CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY CONTRACTOR WITH REGARD TO CONSTRUCTION MEANS, METHODS OR TECHNIQUES. ARCHITECT DOES NOT INTEND TO EXPRESS ANY OPINION, DIRECTION OR INSTRUCTION OF ANY KIND WHATSOEVER AS TO THE MANNER IN WHICH THE CONSTRUCTION WORK IS TO BE ACCOMPLISHED. 39. NOTICE OF DUTY OF COOPERATION: ACCEPTANCE OF THESE DRAWINGS AND SPECIFICATIONS CONSTITUTES AN AGREEMENT FOR FUTURE COOPERATION BETWEEN THE GENERAL CONTRACTOR AND DESIGN CONCEPTS. ALTHOUGH ARCHITECT AND IT'S CONSULTANTS HAVE PERFORMED THEIR SERVICES WITH DUE CARE AND DILIGENCE, THEY CANNOT GUARANTY PERFECTION. ANY AMBIGUITY OR DISCREPANCY IN THE USE OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO ARCHITECT IMMEDIATELY, FAILURE TO COOPERATE SHALL BE SIMPLE NOTICE TO ARCHITECT AND SHALL RELIEVE ARCHITECT FROM RESPONSIBILITY FOR ALL CONSEQUENCES RESULTING THEREFROM. CHANGES MADE FROM THE DRAWINGS AND OR SPECIFICATIONS WITHOUT THE CONSENT OF ARCH- TECT, ARE UNAUTHORIZED AND SHALL RELIEVE ARCHITECT OF ANY RESPONSIBILITY FOR ALL CONSEQUENCES ARISING OUT OF SUCH CHANGE(S). 40. EACH CONTRACTOR AND SUBCONTRACTOR PARTICIPATING IN THE CONSTRUCTION OF THIS "TENANT'S SPACE" SHALL BE DULY LICENSED AND EACH CONTRACT SHALL CONTAIN THE GUARANTEE OF THE CONTRACTOR AND THE SUBCONTRACTOR FOR THE PORTION OF THE TENANT'S WORK. 41. THESE DOCUMENTS ARE THE PROPERTY OF ARCHITECT AND TENANT. NO PART OF THESE DOCUMENTS (DRAWINGS AND SPECIFICATIONS) SHALL BE USED FOR ANY OTHER PROJECT EXCEPT FOR THIS PROJECT WITHOUT THE PRIOR WRITTEN CONSENT OF "ARCHITECT". 1. GENERAL: EXECUTE CLEANING DURING PROGRESS OF THE WORK, AND AT COMPLETION OF THE WORK, AS REQUIRED BY GENERAL CONDITIONS. 2. DISPOSAL REQUIREMENTS: CONDUCT CLEANING AND DISPOSAL OPERATIONS TO COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, REGULATIONS, AND ANTI-POLLUTION LAWS. 3. PRODUCTS: USE ONLY THOSE CLEANING MATERIALS WHICH WILL NOT CREATE HAZARDS TO HEALTH OR PROPERTY, AND WHICH WILL NOT DAMAGE SURFACES. USE ONLY THOSE CLEANING MATERIALS AND METHODS RECOMMENDED BY THE MANUFACTURER OF THE SURFACE MATERIAL TO BE CLEANED. USE CLEANING MATERIALS ONLY ON SURFACES RECOMMENDED BY THE CLEANING MATERIAL MANUFACTURER. 4. EXECUTION: THE GENERAL CONTRACTOR AND SUB-TRADES SHALL EXECUTE PERIODIC CLEANING TO KEEP THE WORK, THE SITE, AND ADJACENT PROPERTIES FREE FROM ACCUMULATIONS OF WASTE MATERIALS, RUBBISH, AND DEBRIS RESULTING FROM CONSTRUCTION OPERATIONS. PROVIDE ON-SITE CONTAINERS FOR THE COLLECTION OF WASTE MATERIALS, DEBRIS, AND RUBBISH. REMOVE WASTE MATERIALS, DEBRIS, AND RUBBISH FROM THE SITE PERIODICALLY, AND DISPOSE OF AT LEGAL DISPOSAL AREAS AWAY FROM THE SITE. 5. DUST CONTROL: CLEAN INTERIOR SPACES PRIOR TO THE START OF FINISH PAINTING, AND CONTINUE CLEANING ON AN AS-NEEDED BASIS UNTIL PAINTING IS FINISHED. SCHEDULE OPERATIONS SO THAT DUST AND OTHER CONTAMINANTS RESULTING FROM CLEANING PROCESS WILL NOT FALL ON WET, NEWLY-COATED SURFACES. 1. UPON COMPLETION OF WORK, CONTRACTOR WILL PROVIDE A BROOM CLEAN AND MOPPED DOWN SPACE. ALL NEW RUBBER BASE SHALL BE FREE OF CONSTRUCTION DUST, ALL CONVECTOR ENCLOSURES CLEANED DOWN AND FREE OF ALL SHOE MARKS AND MATERIAL FRAGMENTS. 2. REMOVE GREASE, MASTIC, ADHESIVES, DUST STAINS, FINGERPRINTS, LABELS AND OTHER FOREIGN MATERIALS FROM SITE EXPOSED INTERIOR AND EXTERIOR SURFACES. 3. WASH AND SHINE GLAZING AND MIRRORS. POLISH GLOSSY SURFACES. 4. PRIOR TO FINAL COMPLETION OR OWNER OCCUPANCY, CONTRACTOR SHALL CONDUCT AN INSPECTION OF SIGHT EXPOSED INTERIOR AND EXTERIOR SURFACES, AND ALL WORK AREAS, TO VERIFY THAT THE ENTIRE WORK AREA IS CLEAN.STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) 1. ALL CONTRACTORS SHALL FULLY INVESTIGATE THE JOB SITE TO COMPARE THE CONTRACT DOCUMENTS AND EXISTING CONDITIONS RELATING TO CONSTRUCTION OF NEW WORK AND LABOR. THE CONTRACTOR SHALL INCLUDE COST FOR ALL WORK DESCRIBED IN THE CONTRACT DOCUMENTS AND REQUIRED OR IMPLIED BY EXISTING CONDITIONS. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE, AND LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIAL REQUIRED OR FOR DIFFICULTIES ENCOUNTERED, WHICH WOULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL NOT BE RECOGNIZED. 2. THE CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY CONFLICTS BETWEEN THE CONSTRUCTION PLANS AND EXISTING CONDITIONS. THE CONTRACTOR SHALL ALSO NOTIFY THE ARCHITECT OF ANY OMISSION OR CONFLICT IN THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE EXECUTION OF THE WORK. ALL CONFLICTS SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF ANY WORK. 3. THE CONTRACTORS SHALL THOROUGHLY REVIEW THE EXISTING CONDITIONS TO IDENTIFY THE IMPACT ON ANY EXISTING FUNCTION, AND SHALL COORDINATE HIS WORK SCHEDULES PRIOR TO COMMENCEMENT OF NEW WORK WITH ARCHITECT AND OWNER. 4. THE CONTRACTORS SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, ALL CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK REQUIRED BY THE CONTRACT DOCUMENTS. 5. UNLESS SPECIFICALLY NOTED TO THE CONTRARY, ALL NEW WORK IS IN CONTRACT. CONTRACTORS SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY TO COMPLETE THE PROJECT OUTLINED ON THIS SET OF PLANS OR REASONABLY INFERABLE FROM THEM. 6. THE CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL BUILDING CODES AND REQUIREMENTS. 7. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY THE LOCAL AUTHORITIES DURING THE COURSE OF THE WORK. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY VARIANCE WITH CODES IN FORCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. 8. ALL CONTRACTORS SHALL PROVIDE AND MAINTAIN PROPER AND SAFE WORKING CONDITIONS AT ALL TIMES INCLUDING BUT NOT LIMITED TO APPROPRIATE TOOLS, EQUIPMENT, SCAFFOLDING, SHORING, ETC. 9. NO SUBSTITUTION OF MATERIALS AND/OR CONSTRUCTION ITEMS SPECIFIED WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT. ALTERNATE EQUAL MANUFACTURERS WILL BE CONSIDERED UP TO 10 DAYS PRIOR TO BID, SO AN ADDENDUM CAN BE ISSUED. IF ITEM IS NOT APPROVED BY WRITTEN ADDENDUM, IT WILL NOT BE ACCEPTED. 10. SUBSTITUTIONS WILL BE ALLOWED WHEN THE SPECIFIED ITEMS CANNOT BE OBTAINED WITHIN THE CONTRACT TIME. SPECIFIED ITEMS ARE TO BE USED AS A GUIDELINE FOR DESIGN. SAMPLES ARE TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL BEFORE SUBSTITUTION. 11. EXTRA COSTS: THE OWNER'S WRITTEN AUTHORIZATION MUST BE OBTAINED PRIOR TO THE ORDERING OF ANY MATERIALS, CONTRACTS, OR THE EXECUTION OF ANY WORK IN EXCESS OF ORIGINAL CONTRACT. 12. ALL ADJACENT WORK SHALL BE PROTECTED FROM DAMAGE CAUSED BY THIS WORK. ANY RECURRENT DAMAGE IS THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. 13. THE CONTRACTOR SHALL KEEP THE PROJECT SITE REASONABLY CLEAN AND FREE FROM HAZARDS AT ALL TIMES. ALL EXISTING EGRESS REQUIREMENTS ARE TO BE MAINTAINED. THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS, BROOM CLEAN THE ENTIRE PROJECT AREA, AND LEAVE THE SITE IN A REASONABLY CLEAN CONDITION DAILY, IN THE JUDGMENT OF THE BUILDING MANAGEMENT. 14. TWO (2) WEEKS PRIOR TO COMPLETION, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT TO COMPLETE A PUNCH LIST OF CORRECTIONS. 15. ALL WORK SHALL COMPLY WITH GOOD TRADE PRACTICE, REGULATIONS OF THE CITY, STATE AND FEDERAL GOVERNMENT AGENCIES HAVING JURISDICTION. 16. CONTRACTOR SHALL INCLUDE IN BID THE REMOVAL OF DEBRIS AND CLEANING AFTER ALL FINISH TRADES. 17. CONTRACTOR TO PREPARE ALL FLOORS FOR NEW FLOOR FINISHES AS INDICATED ON PLAN. 18. VERIFY ALL DIMENSIONS IN THE FIELD. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. 19. SUBMIT FOR ARCHITECT'S REVIEW AND CONSIDERATION ALL BUILDING SAMPLES, PRODUCT LITERATURE AND OTHER PERTINENT DATA OF ANY PROPOSED SUBSTITUTIONS. 20. SUBMIT FOR ARCHITECT'S REVIEW PRIOR TO FABRICATION OR PURCHASE, SHOP DRAWINGS, OR SAMPLES FOR ALL MILLWORK, CUSTOM METAL WORK, INCLUDING CABINETRY, GLASS WALLS AND DOOR ASSEMBLIES AND ALL OTHER ITEMS AS REQUIRED IN THE CONTRACT DOCUMENTS. 21. CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS OF THE PROJECT COME TOGETHER PROPERLY. 22. PROVIDE AND INSTALL ALL PARTITION DOORS AND BUCKS DESIGNATED ON DRAWINGS. 23. PROVIDE SUFFICIENT FRAMING FOR ALL WALL OPENINGS REQUIRED BY DUCTWORK AND RETURN AIR, BOTH ABOVE AND BELOW HUNG CEILING. THESE ARE TO BE COORDINATED WITH HVAC ALTERATION DRAWINGS. 24. ALL PARTITIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS FOR DEFLECTIONS NOT TO EXCEED L/240 OF THE SPAN. 25. CONTRACTOR SHALL REFER TO PARTITION TYPES FOR ACTUAL WALL THICKNESS. 26. ALL DIMENSIONS SHOWN ARE FACE OF STUD OR MASONRY, UNLESS OTHERWISE NOTED. 28. DIMENSIONS NOTED "+/-" ARE THE ONLY DIMENSIONS ADJUSTABLE WITHOUT APPROVAL OF THE ARCHITECT. 30. ALL BUILDING COMPONENTS BELONG TO THE LANDLORD. COORDINATE DEMOLITION, REMOVAL AND STORAGE OF ALL MILLWORK, DOOR FRAMES AND FIXTURES, ETC. WITH LANDLORD. 31. CONTRACTOR SHALL INSPECT EXISTING DEMISING WALLS FOR ALL PENETRATIONS AND SEALS. RETRO FIT ANY PENETRATIONS NOT CONFORMING TO U.L. LISTINGS FOR WALLS AS RATED ON PLAN 33. ALL WORK AND MATERIALS USED TO ACCOMPLISH DESIGNATED WORK SHALL BE COORDINATED WITH CONTRACTOR, TENANT REPRESENTATIVE (WHEN APPLICABLE) AND BUILDING OWNER REPRESENTATIVE WITH RESPECT TO DELIVERY AND STORAGE. 34. CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT APPROVED CONTRACT DOCUMENTS. 35. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL ARCHITECTURAL, MECHANICAL, TELEPHONE, ELECTRICAL (INCLUDING LIGHTING), AND PLUMBING SO TO ENSURE THAT REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ALL EQUIPMENT ARE PROVIDED. 36. THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN CONSENT FROM "ARCHITECT". 37. THIS SET OF DOCUMENTS ARE CONSIDERED AS ONE UNIT AND SHALL NOT BE CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY MANNER. DOCUMENTS SHALL NOT BE SEPARATED FOR THE PURPOSES OF SUBMITTING A BID PROPOSAL OR FOR THE SEPARATE PHASE OF ANY CONSTRUCTION. 27. THE CONTRACTOR SHALL PROVIDE AND INSTALL BRACING AND BLOCKING AS REQUIRED TO SUPPORT ANY WALL-MOUNTED FIXTURES, SHELVING, COUNTER TOPS, CABINETS, ETC. ALL WOOD BLOCKING OR BRACING SHALL BE PRESSURE TREATED, FIRE RETARDANT IN EXTERIOR WALLS AS REQUIRED. 29. THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE EXTINGUISHER CABINET EQUIVALENT TO LARSEN ARCHITECTURAL SERIES SQUARE TRIM SEMI RECESSED FULL GLASS CABINET WITH TYPE 3A:10B:C. FIRE EXTINGUISHER, COLOR ALUMINUM. ALL EXTINGUISHERS SHALL BE SURFACE MOUNTED AT A HEIGHT OF 48" ABOVE THE FINISHED FLOOR (TOP OF CABINET). 32. CONTRACTOR SHALL CONTROL NOISE PRODUCING ITEMS (STEREOS) AND MAINTAIN @ APPROPRIATE LEVELS AT ALL TIMES. FOUL LANGUAGE, ABUSIVE TALK, AND INAPPROPRIATE BEHAVIOR SHALL NOT BE TOLERATED. R. REINF. REFR. R.D. RE: RM REQ'D. R.M.O. S SCHED. S.C. S.F. SECT.SECTION RISER REQUIRED ROOM SCHEDULE SOUTH SQUARE FOOT SOLID CORE REFER TO ... ROOF DRAIN REINFORCED ROUGH MASONRY OPENING REFRIGERATOR SHT. SIM. S.S. SQ. OR STAGG. STIFF STRUC. STL. STD. TR T & B T/ THK. T & G TER. SUSP. TYP. SPEC. STIFFENER SUSPENDED SIMILAR SHEET SQUARE STEEL STANDARD TREAD TOP OF THICK TERRAZZO TYPICAL TOP AND BOTTOM TONGUE & GROOVE STAGGERED STAINLESS STEEL STRUCTURAL SPECIFICATION I.D. INSUL. JAN. INT. KIT. JST. JNT. LAV. LAM. LAB. LT. LAVATORY LIGHT INSULATION JANITOR INTERIOR KITCHEN JOIST JOINT LAMINATE LABORATORY F.D.C. FDN. ELEV. EQUIP. ENCL. EMER EQ. E.W. E.W.C. EXP. F.A. F.D. EXT. FOUNDATION EQUAL EMERGENCY FIRE ALARM FLOOR DRAIN EQUIPMENT EXTERIOR EACH WAY EXPANSION ENCLOSURE ELEVATION FIRE DEPARTMENT CONNECTION ELECTRIC WATER COOLER MAX. MECH. MIN. MEMB. MFR. M.H. MISC. MTL. MUL. M.r.o. NO. N.I.C. NOM. N.T.S. N NOT TO SCALE MISCELLANEOUS MANUFACTURER MAXIMUM MINIMUM MEMBRANE MANHOLE MULLION METAL NORTH NOMINAL NUMBER MECHANICAL F.E. F.E.C. FIN. F.L. F.H.C. FND. F.O.B. FLUOR. FLR. FTG. F.S. FT. GALV. GA. FURR. F.O.C. G.C. F.F. FIRE EXTINGUISHER GENERAL CONTRACTOR FIRE HOSE CABINET FINISH FLOOR FOOTING GAUGE FURRING GALVINIZED FOUNDATION FACE OF BRICK FACE OF CONCRETE FLUORESCENT FOOT OR FEET FULL SIZE FLOW LINE FINSH FLOOR FIRE EXTINGUISHER CABINET MASONRY rough O. NOT IN CONTRACT INSIDE DIAMETER BLK'G. BM. ACT AB. AL. AGGR. A.F.F. ARCH. ALT. APPROX. BLK BLDG. BD. BLOCKING BEAM ACOUSTICAL CEILING TILE ABOVE FINISHED FLOOR ANCHOR BOLT BLOCK BOARD ARCHITECTURAL APPROXIMATE BUILDING ALTERNATE ALUMINUM AGGREGATE B.U.R. BETWEEN. CLG. C.J. C.M.U. COL. CLR. CLKG. CONN. CONT. DEG. C.T. DET./DTL. CONSTR. CONC. B.W. CONCRETE MASONRY UNIT CEILING CLEAR COLUMN DEGREE DETAIL BUILT UP ROOFING CONTROL JT. CONNECTION CONSTRUCTION CERAMIC TILE CONCRETE CONTINUOUS CAULKING BOTH WAYS BETWEEN BOT.BOTTOM T.O.W. T.O.C. T.O.S. U.N.O. VERT. VER VCT W W/ W.C. WD. C W/O P VERTICAL VERIFY WEST WITH WOOD WITHOUT L L PLATE TOP OF WALL TOP OF CONCRETE TOP OF STEEL UNLESS NOTED OTHERWISE VINYL COMPOSTION TILE CENTERLINE WATER CLOSET OPG. O.D. OH. PCT. P.L. OPP. PLYWD. PLAS. PR. Q.T. P.LAM. PROPERTY LINE QUARRY TILE OVERHEAD OPENING PRE-CAST OPPOSITE PLYWOOD PLASTER PAIR G.W.B. GR. GYP. H.C. H.B. GYP. BD. H.M. HDWE. HDWD. HT. HVAC HR. H/C GYPSUM WALL BOARD GYPSUM GRADE HEIGHT HOUR HANDICAPPED HOLLOW CORE GYPSUM BOARD HOLLOW METAL AIR CONDITIONING HARDWARE HARDWOOD HOSE BIBB HEATING, VENTILATION AND PLASTIC LAMINATE OUTSIDE DIAMETER DIAG. DN. DIA. E DS. DWG. E.J. E.I.F.S. EA. (E) ELEC. EL. ELEV. DOWN EAST EACH ELECTRICAL EXPANSION JOINT ELEVATION EXISTING DIAGONAL DIAMETER DOWNSPOUT DRAWING D.F.DRINKING FOUNTAIN G.L.O.C.GLASS ON CENTER LOCATION SITE DETAIL REFERENCE SECTION REFERENCE COLUMN LINE NUMBER ELEVATION REFERENCE WHICH DETAIL APPEARS INDICATES SHEET UPON INDICATES DETAIL NUMBER OR ELEVATION DOOR NUMBER EXTERIOR INSULATION AND FINISH SYSTEM ABBREVIATIONS NOT LISTED. NOTE: CLARIFY WITH ARCHITECT ALL NORTH R.O.ROUGH OPENING M.O.MASONRY OPENING 1 RM NAME RM # 62'-6 5/16"DIAGONAL DISTA NCE 53'-0 1 /2" MAX TRAVEL DIST. TO EXIT 69'-8"SEPARATIONOF EX ITS MAX COMMON PATH OF TRAVEL 50'-4" ENTRY 101 HOSTESS 102 SALES FLOOR 104 SEATING AREA 103 BAR 105 PREP AREA 106 WALK IN COOLER 107 OFFICE 108 CORRIDOR 109 RESTROOM WOMEN'S 111 RESTROOM MEN'S 110 KEY PLAN SUITE '2'&'3' SCALE: 1/4" = 1'-0"STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21)NORTH NOTES: 1. CONTRACTOR SHALL PROVIDE TACTILE SIGNAGE PER NFPA 101 7.10.1.3. READING "EXIT" AT ALL EXTERIOR DOORS. 2. CONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE DISCONNECT & SIGNAGE PER NFPA 70 230.70 & NFPA 1 11.1.7. 3. ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 101 SECTION 7.8 AND FBC 1008.3. 4. ALL NEW INTERIOR FINISHES SHALL COMPLY WITH NFPA 101 10.2 AND FBC 803 & 804 FLORIDA BUILDING CODE 7TH EDITION (2020) FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) FLORIDA BUILDING CODE MECHANICAL 7TH EDITION (2020) FLORIDA BUILDING CODE PLUMBING 7TH EDITION (2020) NATIONAL ELECTRIC CODE / NFPA 70 NEC (2017) FLORIDA BUILDING CODE FUEL GAS 7TH EDITION (2020) FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020) FLORIDA ACCESSIBILITY CODE 7TH EDITION (2020) FLORIDA BUILDING CODE ENERGY CONSERVATION 7TH EDITION (2020) 1.SCOPE OF PROJECT INVOLVES A LEVEL II ALTERATION OF A 1,917 S.F. INTERIOR TENANT BUILD OUT FOR A NEW TAVERN. WORK INCLUDES NEW MECHANICAL, ELECTRICAL, AND PLUMBING; NEW BATHROOMS, PREP AREA, ACCESSORY OFFICE, SEATING AREA, AND FINISHES THROUGHOUT. 2.TO THE BEST OF OUR KNOWLEDGE, INFORMATION, AND INTENT, BUILDING ALTERATIONS WERE DESIGNED TO AND COMPLY WITH THE APPLICABLE CODES LISTED ABOVE. 3.INSPECTION OF EXISTING RATED WALLS BY ARCHITECT IS A LIMITED OBSERVATION AND DOES NOT CONFIRM THE ENTIRE EXISTING ASSEMBLY CONDITION. ADDITIONAL WORK MAY BE REQUIRED IF, DURING ANY CONSTRUCTION PHASE, THE WALL/CEILING IS DETERMINED TO BE DEFICIENT INCLUDING BUT LIMITED TO: A. FIRE CAULK ALL PIPE PENETRATIONS PER UL W-L-1054 FOR METAL PIPES AND UL W-L-2098 FOR PVC. B. SEAL WALL TO METAL DECK PER UL U-379 REQUIREMENTS. C. FILL ANY HOLES IN WALL MISSING GWB WITH 5/8" FIRE RATED GWB PER UL U-379 REQUIREMENTS. 4.ALL VISIBLE EMERGENCY LIGHTS AND EXIT SIGNS OBSERVED ARE INDICATED ON PLAN. OWNER SHALL PROVIDE ADDITIONAL FIXTURES AS INDICATED ON LIFE SAFETY PLAN AND REQUIRED BY AHJ. 5.OWNER SHALL VERIFY BATTERY BACKUP CIRCUITS ARE PRESENT & MEET THE REQUIREMENTS OF NFPA 101 7.8 AND FBC 1008.3. PROVIDE IS NECESSARY. NORTH FIRE EXTINGUISHER EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXIT / EMERGENCY LIGHT FIXTURE COMBO 1 HOUR RATED PARTITION 2 HOUR RATED PARTITION LIGHT HAZARD OFFICES, CLASSROOMS, CHURCHES, ASSEMBLY HALLS, HOTEL OR MOTEL GUESTROOMS, ETC. ORDINARY HAZARD DINING AREAS, MERCANTILE SHOPS AND ALLIED STORAGE, LIGHT MANUFACTURING, RESEARCH OPERATIONS, AUTO SHOWROOMS, PARKING GARAGES, WORKSHOP OR SUPPORT SERVICE AREAS OF LIGHT HAZARD OCCUPANCIES AND WAREHOUSES CONTAINING NFPA 13 CLASS I OR CLASS II COMMODITIES. EXTRA HAZARD WOOD WORKING, VEHICLE REPAIR, AIRCRAFT AND BOAT SERVICING, COOKING AREAS, INDIVIDUAL PRODUCT DISPLAY SHOWROOMS, PRODUCT CONVENTION CENTER DISPLAYS AND STORAGE AND MANUFACTURING PROCESS SUCH AS PAINTING, DIPPING, AND COATING INCLUDING FLAMMABLE LIQUID HANDLING. WAREHOUSING OR IN‐]PROCESS STORAGE OF OTHER THAN NFPA 13 CLASS I OR CLASS II COMMODITIES. PORTABLE FIRE EXTINGUISHERS MAXIMUM PROTECTED AREA 2A-10B:C LIGHT A = 3,000 SF 2A-10B:C 3,000 ORDINARY A = 1,500 SF 3A-40B:C 9,000 LIGHT 3A-40B:C 4,500 ORDINARY 4A-80B:C 11,250 LIGHT 4A-80B:C 6,000 ORDINARY 4A-80B:C 4,000 EXTRA A = 1,000 SF MIN. PLUMBING FACILITIES REQ'D. OCCUPANCY AND CONSTRUCTION TYPE (BASED ON HIGHER SEAT COUNT) EXITS TRAVEL DISTANCE SEPARATION REQUIREMENTS FIRE RATED SEPARATION REQ'D BETWEEN ASSEMBLY AND BUSINESS OCCUPANCIES 2-HR SEPARATION, PER FBC TABLE 508.4 OCCUPANCY TYPE: 'A-2' ASSEMBLY PER FBC 303.3 CONSTRUCTION TYPE: 'IIIA' PER FBC TABLE 601, NON-SPRINKLERED TOTAL AREA: 1,917 G.S.F. EXIT UNITS REQ'D = 64 X .2" = 12.8 (32" MIN) 2 EXITS REQUIRED PER FBC TABLE 1006.3.1 PROVIDED 3 EXITS = 99" TOTAL EXIT UNITS MIN. SEPARATION BETWEEN EXITS ≥1/2 MAX. DIAGONAL DISTANCE PER FBC 1007.1.1 MIN. SEPARATION REQUIRED: 1/2 X 62'-6" = 31'-3" , (ACTUAL) = 53' GROUP 'A-2' ASSEMBLY, NON-SPRINKLERED MAXIMUM COMMON PATH OF TRAVEL ALLOWED:(ACTUAL) = 50'-4" 75'-0" PER FBC TABLE 1006.2.1 MAXIMUM TRAVEL DISTANCE ALLOWED:(ACTUAL) = 69'-8" 200'-0" PER FBC TABLE 1017.2 MAXIMUM DEAD END CORRIDOR DISTANCE ALLOWED:(ACTUAL) = 0 20'-0" PER FBC 1020.4 OCCUPANCY AND CONSTRUCTION TYPE (BASED ON HIGHER SEAT COUNT) EXITS TRAVEL DISTANCE SEPARATION REQUIREMENTS FIRE RATED SEPARATION REQ'D BETWEEN ASSMEBLY AND BUSINESS OCCUPANCIES 2-HR SEPARATION, PER NFPA 101 TABLE 6.1.14.4.1(A) OCCUPANCY TYPE: ASSEMBLY PER NFPA 101 6.1.2 CONSTRUCTION TYPE: 'III211' PER NFPA 220 4.4, NON-SPRINKLERED TOTAL AREA: 1,917 G.S.F. EXIT UNITS REQ'D = 69 X .2" = 13.8 (32" MIN) 2 EXITS REQUIRED PER NFPA 101 7.4.1.1 PROVIDED 3 EXITS = 99" TOTAL EXIT UNITS MIN. SEPARATION BETWEEN EXITS ≥1/2 MAX. DIAGONAL DISTANCE PER NFPA 101 7.5.4.2 MIN. SEPARATION REQUIRED: 1/2 X 62'-6" = 31'-3" , (ACTUAL) = 53' GROUP 'A-2' ASSEMBLY, NON-SPRINKLERED MAXIMUM COMMON PATH OF TRAVEL ALLOWED:(ACTUAL) = 50'-4" 20'-0" (SERVING > 50 OCC.) PER NFPA 101 12.2.5.1.2 75'-0" (OCC. LOAD ≤ 50), PER NFPA 101 12.2.5.1.2 MAXIMUM TRAVEL DISTANCE ALLOWED:(ACTUAL) = 69'-8" 200'-0" PER NFPA 101 12.2.6.2 MAXIMUM DEAD END CORRIDOR DISTANCE ALLOWED:(ACTUAL) = 0 20'-0" PER NFPA 101 12.2.5.1.3 64 OCCUPANTS: 32 FEMALES / 32 MALES W.C. - REQ'D. - 1 PER 40 32 FEMALES = 1 REQ'D - PROVIDED: 1 32 MALES = 1 REQ'D - PROVIDED: 1 LAV. - REQ'D. - 1 PER 75 32 FEMALES = 1 REQ'D - PROVIDED: 1 32 MALES = 1 REQ'D - PROVIDED: 1 **D.F. - 0 REQ'D SERVICE SINK -1 REQ'D - PROVIDED: 1 PER FBC, PLUMBING TABLE 403.1 EXIT: CLEAR WIDTH: 33" CAPACITY: 165 OCC. EXIT: CLEAR WIDTH: 33" CAPACITY: 165 OCC. EXIT: CLEAR WIDTH: 33" CAPACITY: 165 OCC. OCCUPANT LOAD - FBC TABLE 1004.5 ROOM USE AREA SF SF/ OCC._ TOTAL OCC ENTRY WAITING AREA 86 15 GROSS 5.7 HOSTESS BUSINESS 53 150 GROSS 0.4 SEATING AREA UNCONCENTRATED (TABLES & CHAIRS)471 15 NET 31.4 SALES FLOOR MERCANTILE 146 60 GROSS 2.43 BAR SEATING LINEAR INCHES 372 18 LINEAR INCHES 20.67 BAR BUSINESS 187 150 GROSS 1.25 PREP AREA/COOLER COMMERCIAL KITHCEN 302 200 GROSS 1.5 OFFICE BUSINESS 134 150 GROSS 0.89 TOTAL 63.3 OCCUPANT LOAD -NFPA 101 TABLE 7.3.1.2 ROOM USE AREA SF SF/ OCC. TOTAL OCC ENTRY WAITING AREA 86 15 5.7 HOSTESS BUSINESS 53 150 0.4 SEATING AREA UNCONCENTRATED (TABLES & CHAIRS)471 15 31.4 SALES FLOOR MERCANTILE 146 30 4.87 BAR SEATING LINEAR INCHES 372 18 20.67 BAR BUSINESS 187 150 1.25 PREP AREA/COOLER COMMERCIAL KITHCEN 302 100 3.02 OFFICE BUSINESS 134 150 0.89 TOTAL 68.2 F.E. EXISTING DEMISING WALL. 2-HR FIRE RATING REQUIRED. G.C. TO VERIFY CONDITION. SEE NOTE TO PLAN REVIEWER #3 EXISTING CMU EXTERIOR WALL F.E. TOTAL OCCUPANTS 64 TOTAL OCCUPANTS 69 **DRINKING FOUNTAIN NOT REQUIRED PER FBC-P 410.4 (RESTAURANTS SERVING WATER IN CONTAINER FREE OF CHARGE) N.T.S. 1 1 02/08/22 REMOVED DRIVE-THRU WINDOW, BOLLARD, & CANOPY. 1 1 1 1 1 1 1 1 1 1 1 1 2 2 33 4 44 5 5 KEY PLAN SUITE '2'&'3' 1 REMOVE ALL INTERIOR PARTITIONS, CEILINGS, LIGHTING, FLOOR FINISHES AS REQUIRED FOR NEW WORK. REMOVE EXISTING PLUMBING FIXTURES, AND FINISHES AS REQUIRED FOR NEW WORK. GWB CEILING TO REMAIN. EXISTING INSWING DOOR TO BE MODIFIED TO OUTSWING. REUSE OR REPLACE EXISTING HARDWARE & FRAME AS APPLICABLE. GC TO COORDINATE. REMOVE EXISTING MILLWORK REMOVE & RELOCATE ELECTRICAL PANEL. SEE ELECTRICAL DWG FOR DISTRIBUTION. 2 3 4 5 1.REMOVE ALL EXISTING CONSTRUCTION AS REQUIRED FOR NEW CONSTRUCTION. 2.PATCH AND REPAIR ALL WALLS AND RELATED FINISHES ADJACENT TO AREAS OF DEMOLITION, WHERE DEMOLITION AFFECTED THE EXISTING FINISHES. 3.CONTRACTORS SHALL COORDINATE THE SEQUENCE FOR DEMOLITION. 4.REMOVE ALL CONSTRUCTION SHOWN ON THE DRAWINGS AS EXISTING TO BE REMOVED, INCLUDING, BUT NOT LIMITED TO: PARTITIONS, HANGERS, STRAPS AND OTHER ACCESSORY OBJECTS CONNECTED WITH THE ITEMS BEING REMOVED. 5.WHERE WATER LINES OR DRAINS TO EXISTING PLUMBING FIXTURES ARE DISCONNECTED AND NOT REUSED. THEY SHALL BE CAPPED AT THE TAP CONNECTION, AND ADEQUATELY RECESSED TO ACCOMMODATE PATCHING OF FINISHED WALL OR FLOOR FOR A SMOOTH FLUSH APPEARANCE. 6.THE DISCONNECT OF ALL ELECTRICAL DEVICES REMOVED SHALL BE AT THE SUPPLY JUNCTION BOX OUTLETS AND SWITCHES SHALL BE STORED ON SITE FOR REUSE WHERE FEASIBLE. 7.NEWLY ABANDONED OR EXISTING ABANDONED PLUMBING WHICH IS EXPOSED SHALL BE CUT, CAPPED AND ADEQUATELY RECESSED TO ACCOMMODATE PATCHING OF FINISHED WALL FLOOR OR CEILING FOR A SMOOTH FLUSH APPEARANCE. 8.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE DUST PROTECTION TO KEEP ALL DUST & DEBRIS SEPARATED FROM HVAC SYSTEM AND NON CONSTRUCTION AREAS. TEMPORARY BARRIER WALLS AND DUST PROTECTION SHALL REMAIN UNTIL ALL WORK AND CLEAN UP IS FINAL. CONTRACTOR SHALL SUBMIT DUST MAINTENANCE PLANS AND PROCEDURES TO TENANT FOR APPROVAL PRIOR TO START OF CONSTRUCTION. 9.GENERAL CONTRACTOR IS TO EXPLORE SITE AND BUILDING AND NOTIFY ARCHITECT OF ANY POSSIBLE PROBLEMS OR DRAWING EXCLUSIONS PRIOR TO COMMENCING WITH PROJECT. 10.SEE CIVIL PLANS FOR ADDITIONAL EXTERIOR DEMOLITION WORK AS REQUIRED. EXISTING WALLS TO REMAIN EXISTING WALLS TO BE DEMOLISHED STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) SCALE:1/4"=1'-0" NORTH NORTH NOTE: DEMOLITION SHEET INCLUDED FROM PREVIOUSLY SUBMITTED DEMOLITION PERMIT SET. 3 4 11 55 6 7 8 9 10 11 11 12 13 14 14 15 16 16 1616 171841 1920 2122 23 232424242525 26 27 27 27 27 27 27 28 29 30 31 32 33 34 34 35 35 35 13'-10 1/4"27'-7 3/4"12'-0 1/4" 6'-3 1/4" 26 5'-9"18'-7 3/8"5'-4 7/8"3'-7 1/2"8'-7 7/8"7'-5 1/8"10'-2 1/2"15'-5"2'-0"6'-9 1/2"2'-1"22'-0 1/2"ENTRY 101 HOSTESS 102 SALES FLOOR 104 SEATING AREA 103 BAR 105 PREP AREA 106 WALK IN COOLER 107 OFFICE 108 9'-0 3/8"18'-7 3/8"5'-9"6'-3 1/4"7'-0"2'-0"4'-10 1/4"19'-7 3/4"7'-7 1/8"7'-2 7/8"30 CORRIDOR 109 RESTROOM WOMEN'S 111 RESTROOM MEN'S 110 3 33 1 1 1 1 2 1 32 3 3 1 A-3.0 3'-0"9'-0 1/4"1'-0"8'-0" 2'-0"10'-0"2'-6" 2'-6"2'-6" 9'-5"2'-4 1/2"7'-10"10'-2"1'-6"1'-6"3'-6 1/4"110 111 108B 108A 108C 109 106 103101 1 A-4.01'-0"38 49'-8"EXISTING COVERED WALKWAY48'-4"39 40 3 KEY PLAN SUITE '2'&'3' 1 NEW OUTSWING DIRECTION. PER DEMO PLAN. 3 NEW ELECTRICAL PANEL LOCATION - SEE ELECTRICAL DWGS. (FUTURE) 100LBS CO2 TANK LOCATION4 DESK SELECTED & PROVIDED BY OWNER5 MOP SINK - SEE PLUMBING DWGS.6 AVANTCO A-19R-HC 29" REFRIGERATOR OR EQUIVALENT 7 REGENCY 24" X 24" NSF WIRE 5-SHELF OR EQUIVALENT 8 REGENCY 41" TWO COMPARTMENT SINK OR EQUIVALENT 9 REGENCY 30" X 72" SS WORK TABLE OR EQUIVALENT 10 PANASONIC NE-SCV22NAPR COUNTERTOP MICROWAVE CONVECTION OVEN OR EQUIVALENT 11 STORAGE SHELF SELECTED & PROVIDED BY OWNER 12 BEER RACK SELECTED & PROVIDED BY OWNER13 KEG RACK SELECTED & PROVIDED BY OWNER14 8'Wx18'Dx8'H BARR WALK-ON COOLER. G.C. TO COORDINATE INSTALL 15 CLOVER POINT OF SALE SYSTEM SELECTED AND PROVIDED BY OWNER 16 UNDER COUNTER COOLER - ARCTIC AIR ABB72G 72" OR EQUIVILANT 17 ROYAL INDUSTRIES WT 3624 36" WORK TABLE (OR EQUIVALENT) 18 MOTAK DISH DSP3 UNDER COUNTER GLASS WASHER OR EQUIVALENT 21 STEELTON 3 BOWL UNDER BAR SINK OR EQUIVALENT 22 AMERICAN BEVERAGE GLASS RINSER DRIP TRAY OR EQUIVALENT 23 ADVANCE TABCO EDC-1548 48" DISH CABINET OR EQUIVALENT 24 WALL MOUNT 12 FAUCET DISPENSER AIR COOLED OR EQUIVALENT 25 PROCOOL CST-2000 3 DOOR BEVERAGE COOLER OR EQUIVALENT 26 BEER DISPLAY RACK SELECTED & PROVIDED BY OWNER 27 MERCHANDISE DISPLAY SHELVES SELECTED & PROVIDED BY OWNER 28 RECEPTION COUNTER W/ MERCHANDISE DISPLAY BELOW SELECTED & PROVIDED BY OWNER. G.C. TO INSTALL 29 COUNTER TO BE ADA HEIGHT PER FBC - ACCESSIBILITY 226 THAT COMPLY WITH FBC - ACCESSIBILITY 902 30 COMMUNITY TABLE & CHAIRS SELECTED & PROVIDED BY OWNER 31 HIGH TOP TABLE & CHAIRS SELECTED & PROVIDED BY OWNER 32 DINING TABLES TO BE ADA HEIGHT PER FLORIDA BUILDING CODE - ACCESSIBILITY 226 THAT COMPLY WITH FLORIDA BUILDING CODE - ACCESSIBILITY 902. PROVIDED BY OWNER 33 LEATHER LOUNGE COUCH SELECTED & PROVIDED BY OWNER 34 LOUNGE TABLE & CHAIRS SELECTED & PROVIDED BY OWNER 35 BAR STOOLS SELECTED & PROVIDED BY OWNER38 REGENCY 15" X 36" 304 STAINLESS STEEL DISH CABINET W/ INNOVECO CO2 GLASS CHILLER, OR EQUIVALENT. PROVIDED BY OWNER. 39 20 LBS C02 TANK. PROVIDED BY OWNER.40 SPLASH WM900 12"W WALL MOUNT HAND SINK OR EQUIVALENT 19 AVANTCO ICE UC-160-FA 26" UNDER COUNTER ICE MACHINE OR EQUIVALENT 20 ROYAL INDUSTRIES WT 3624 36" WORK TABLE OR EQUIVALENT, W/ RAPID BEVERAGE CHILLER SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE WATER SUPPLY LINE FROM COOLER & ELECTRICAL SUPPLY. 41 1 TYPE 1: NEW INTERIOR WALL PARTITION - SEE SECTION 1/A-2.0 2 EXISTING INTERIOR WALL PARTITION TO REMAIN TYPE 2: NEW INTERIOR WALL PARTITION - SEE SECTION 2/A-2.0 3 TYPE 3: NEW INTERIOR WALL PARTITION - SEE SECTION 2/A-2.0 GENERAL NOTES: 1.DOORS 6" FROM FACE OF WALL OR CENTERED AS SHOWN, UNLESS NOTED OTHERWISE. 2.DIMENSIONS ARE TO EXISTING FINISH FACE AND FACE OF NEW STUDS, UNLESS NOTED OTHERWISE. 3.PATCH & REPAIR EXISTING WALLS & CEILINGS AS REQUIRED 4.NEW FLOOR FINISH THROUGHOUT. PROVIDE TRANSITION STRIP BETWEEN ROOMS WITH DIFFERENT FLOOR FINISHES. AS APPLICABLE. 5.ALL DOORS TO RECEIVE LEVER-TYPE COMMERCIAL GRADE ACCESSIBLE HARDWARE ON ALL DOORS. SEE DOOR SCHEDULE. 6.SEE FINISH PLAN & SCHEDULE FOR ALL FINISHES. 7.OWNER TO APPROVE & PROVIDE FINAL SELECTION OF ALL BAR EQUIPMENT. 8.G.C. TO COORDINATE INSTALL AND PROVIDE POWER/WATER SUPPLY FOR ALL BAR EQUIPMENT.STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) SCALE:1/4"=1'-0" NORTH NORTH 1 02/08/22 REMOVED DRIVE-THRU WINDOW, BOLLARD, & CANOPY. 1 1 1 L3 L2 3'-6"2'-8"4'-0"5'-7"5'-7"4'-0"6'-0"3'-0"5'-8"2'-0"L2 5'-8"EQ.EQ. EQ.EQ.EQ.EQ. G.W.B. 9'-0" G.W.B. 9'-0" L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2 L2L2 L2 L2 L1 L1 3'-6"9'-8"4'-8"19'-9" 5'-4" 6'-1" 7'-4"3'-8"3'-6"5'-0"7'-2"5'-0"EQ.EQ.5'-3"5'-3"3'-10" EQ.EQ.4'-8"4'-8"3'-0"G.W.B. 11'-11"2'-0"3'-2"2'-0"G.W.B. 11'-11" G.W.B. 11'-11" C.T. 10'-0" G.W.B. 11'-11" G.W.B. 11'-11" G.W.B. 11'-11" G.W.B. 9'-0" G.W.B. 11'-11" 1'-4" TYP. 1'-8 1/2"5'-0"2'-0"3'-2"2'-0"A-1.2 1 L2 L27'-4"2'-4"5'-4 1/4" 6'-8"6'-8"6'-8"3'-6"1'-10"3'-6"EQ.EQ.4'-11"8'-8" CEILING LEGEND G.W.B. CEILING, PATCH & REPAIR EXISTING G.W.B. AS REQUIRED NEW 4.5" ROUND DOWNLIGHT 4DR- TL L10 8 80 35 DIM UNV 0 W 07 CS N F1 OR EQUIVALENT. CEILING EXHAUST GRILL/FAN- SEE ELECT. DWGS. EXIT SIGN WITH EMERGENCY LIGHTS- BEGHELLI PCH R SA AT - OR EQUIV. COORDINATE WITH G.C. AND OWNER. EMERGENCY LIGHTS- BEGHELLIL PEH-1 AT - OR EQUIV. COORDINATE WITH G.C. AND OWNER NEW LUMETTA REVEAL CONE 4" PENDANT P1000RV DIMM. OR EQUIVALENT. NEW CDS LIGHTING REMUS LED PENDANT DIMM. OR EQUIVALENT.L1 L2L2 CONTECH LIGHTING CTL 7516-B FAMING PROJECTOR TRACK FIXTURE LEO RETRO FIT MR16 LAMP CIRCUIT TRACK FIXTURE ADAPTER TO BE LA1816-B (OR EQUIVALENT). SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE INSTALL & LOCATION. LED NARROW STRIP LIGHT- WILLIAMS 75R 2 L15 840 DRV UNV OR EQUIVALENT. NEW VONN LIGHTING DELPHINUS VVC31013 SN 35" LED LINEAR CHANDELIER DIMM. OR EQUIVALENT.L3 ARMSTRONG METALWORKS BLADES - CLASSICS, LINEAR PANELS W/ SOUND ABSORPTION. SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE INSTALL OVER SEATING AREA. PROJECTION SCREEN MOUNTED TO SUSPENDED CEILING SYSTEM. SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE INSTALL. INTEGRATED LED COVE LIGHTING. G.C. TO COORDINATE ALL RUN LENGTHS & INSTALL. SUSPENDED METAL CEILING TILE SYSTEM, SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE INSTALL. JUNCTION BOX FOR COOLER LIGHTING, COORDINATE W/ G.C., MANUFACTURER, & INSTALLER. KEY PLAN SUITE '2'&'3' HANGER WIRE TO STRUCTURE HANGER WIRE TO STRUCTURE COVE LIGHT FIXT. - SEE RCP. FOR TYPE OWNER PROVIDED GRID SYSTEM SCALE: 1 1/2" = 1'-0" 1 A-1.2 OWNER PROVIDED METAL CEILING TILES RECESSED LIGHT FIXTURE - CEILING LEGEND OWNER PROVIDED RETRACTABLE PROJECTION SCREEN STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) SCALE: 3/8" = 1'-0" NORTH NORTH 1 02/08/22 REVISED FLOOR PLAN 1 SCALE: 3/4" = 1'-0" 1 A-2.0 CONT. RUNNER TRACK SAME GA. AS STUDS. SECURE TO SLAB W/ 3/4" POWER DRIVEN PIN @ 16" O.C. 3 5/8" MTL. STUDS @ 16" O.C. - FLOOR TO B.O. ROOF DECK 20 GA. MTL. "C" STUDS (TYP. @ ALL PARTITIONS U.N.O.) PROVIDE HORIZ. BRACING @ 4'-0" O.C. AS REQUIRED. 5/8" GYP. BD. EACH SIDE W/ 3 1/2" FIBERGLASS INSULATION BATT BETWEEN FOR SOUND ATTENUATION *PROVIDE MOISTURE RESISTANT GYP. BD. AT ALL WET WALLS EXISTING CONC. FLOOR SLABEXISTING CEILING HEIGHTTOP TRACK BASE - SEE FINISH SCHEDULE EXISTING G.W.B. CEILING SCALE: 3/4" = 1'-0" 2 A-2.0 CONT. RUNNER TRACK SAME GA. AS STUDS. SECURE TO SLAB W/ 3/4" POWER DRIVEN PIN @ 16" O.C. 3 5/8" MTL. STUDS @ 16" O.C. - FLOOR TO B.O. ROOF DECK 20 GA. MTL. "C" STUDS (TYP. @ ALL PARTITIONS U.N.O.) PROVIDE HORIZ. BRACING @ 4'-0" O.C. AS REQUIRED. 5/8" GYP. BD. EACH SIDE W/ 3 1/2" FIBERGLASS INSULATION BATT BETWEEN FOR SOUND ATTENUATION *PROVIDE MOISTURE RESISTANT GYP. BD. AT ALL WET WALLS EXISTING CONC. FLOOR SLABSEE REFLECTED CEILING PLANTOP TRACK BASE - SEE FINISH SCHEDULECEILING HEIGHT6"3-5/8" METAL STUDS @ 24" OC. 1/2" CEILING GRADE GYP. BD. 3-5/8" METAL STUDS @ 24" OC. BRACE STUDS BACK TO STRUCTURE AS REQUIRED SCALE: 3/4" = 1'-0" 3 A-2.0 CONT. RUNNER TRACK SAME GA. AS STUDS. SECURE TO SLAB W/ 3/4" POWER DRIVEN PIN @ 16" O.C. 3 5/8" MTL. STUDS @ 16" O.C. - FLOOR TO B.O. ROOF DECK 20 GA. MTL. "C" STUDS (TYP. @ ALL PARTITIONS U.N.O.) PROVIDE HORIZ. BRACING @ 4'-0" O.C. AS REQUIRED. 5/8" GYP. BD. EACH SIDE W/ 3 1/2" FIBERGLASS INSULATION BATT BETWEEN FOR SOUND ATTENUATION *PROVIDE MOISTURE RESISTANT GYP. BD. AT ALL WET WALLS EXISTING CONC. FLOOR SLABSEE REFLECTED CEILING PLANTOP TRACK BASE - SEE FINISH SCHEDULECEILING HEIGHT1/2" CEILING GRADE GYP. BD. 3-5/8" METAL STUDS @ 24" OC. EXISTING G.W.B. CEILING SEE REFLECTED CEILING PLANCEILING HEIGHTSTATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) 1 1 02/08/22 REMOVED BOLLARD & DRIVE THRU WINDOW DETAILS 1.PROVIDE EPOXY PAINTED M.R. G.W.B. AT WET WALLS. 2.PROVIDE 3-1/2" SOUND BATTS IN ALL WALLS. 3.ALL FIXTURES AND ACCESSORIES TO BE BARRIER FREE. SEE THIS SHEET FOR MOUNTING HEIGHTS LEGEND AND TYPICAL FIXTURE & ACCESSORY HEIGHTS. 4.PROVIDE INTERNATIONAL SYMBOL FOR H.C. RESTROOMS - MOUNT ON LATCH SIDE OF DOOR, 60" A.F.F. TO CENTER OF SIGNAGE. SIGNAGE PER ADA REQUIREMENTS. 5.GENERAL CONTRACTOR TO FURNISH AND INSTALL ALL TOILET ACCESSORIES. 6.BATHTUB TO BE SELECTED BY OWNER. 7.ADDITIONAL FREE-STANDING WASTE RECEPTACLES BY TENANT. ACCESSORIES ARE MANUFACTURED BY BOBRICK, UNLESS NOTED OTHERWISE 42" GRAB BAR 36" GRAB BAR MIRROR (18" X 36") - SURFACE MTD. TOILET TISSUE DISPENSER - DBL. ROLL TYPE - WALL SURFACE MTD. PAPER TOWEL DISPENSER E D C A B B-6806 X 42 (OR EQ.) B-6806 X 36 (OR EQ.) B-4288 (OR EQ.) B-165 1836 (OR EQ.) B-4262 (OR EQ.) F SOAP DISPENSER B-818615 (OR EQ.) G SANITARY NAPKIN DISPOSAL B-254 (OR EQ.)- SURFACE MTD. - SURFACE MTD. SPOUT HEIGHT AND KNEE CLEARANCEWHEELCHAIR TURNING SPACE CLEAR FLOOR SPACE 4'-1 3/4"4'-0"5'-0"5'-0"CLEARMIN.MIN.8"6" 1'-7" EQUIPMENT PERMITTED IN SHADED AREA PROVIDE ACCESSORY APRON TO BOTTOM OF HIGHER DRINKING FOUNTAIN TO COMPLY WITH ADA 27" FLOOR TO UNDERSIDE REQUIREMENT FBAC 307.1'-0 1/2"2'-3"3'-0"2'-3"MAX1'-0 1/2"2'-3"3'-0"MAX1'-7"2'-10" MAX.3'-4"HANDICAPMAX.MIRROR WATER PIPING ON H.C. SINK COVER DRAIN INSULATE OR 2'-5"2'-10"MIN.MAX.8" 6"9"PROVIDE BLOCKING AS REQUIRED 8"C TOILET PAPER DISPENSER OUTLET MAY BE LOCATED BETWEEN 15" A.F.F. TO 32" A.F.F. - MUST MAINTAIN 1-1/2" CLEAR BELOW GRAB BAR 1'-3" C MIN.NOTE: HEIGHTS SHOWN AS PER 2017 FLORIDA ACCESSIBILITY REQUIREMENTS MANUAL. A MODIFIED VERSION OF ANSI A117.1 2009 AND AMERICANS WITH DISABILITIES ACT, 2010 (A.D.A.).1'-6"HANDICAPFLUSH ON SINK SIDE OF TOILET 2'-0"1'-0" 1'-5" C 5'-0" 3'-0" MIN.MIN. MIN. 1'-0"3'-6" MAX.MIN. 4'-6" MIN. LAVATORY MIRROR 2'-11"TOP OF BAR1 1/2" GRAB BAR W/ 1 1/2" CLEARANCE FROM WALL. IF LONGER THAN 32", SECURE AT CENTER ALSO.1 1/2"CLEAR1'-0"CLEAR1'-3"4'-0"SOAP DISP.ELECTRIC HAND DRYER - IF APPLICABLE 25" TO 30"SANITARY NAPKIN DISPOSAL 4'-6"RECOMMENDEDTO TOP5'-2"RECOMMENDEDTO TOP3'-0 1/8"42" to 46"RECESSED WASTE RECEPTACLE RECESSED SANITARY NAPKIN VENDOR 30" TO 48"TOILET SEAT COVER DISPENSER 2'-9"TO CHANGINGSURFACE3'-8"FLOOR TO HANDLEAREA2'-4 3/4"2'-4 3/4"BOTTOM CLOSEDBEDBOTTOM OFBEDKB200-SS BABY CHANGING STATION 2'-9"REACH RANGEFRONT SIDE 38" TO 40"HEAVY DUTY CLOTHES HOOK REACH RANGE - SHOWN HATCHED PAPER TOWEL DISP.5'-2"RECOMMENDEDTO TOPPAPER TOWEL DISP. / WASTE RECEPTACLE5'-0"MINIMUM4'-0"MAXIMUMSIGN BASELINE OF THE LOWEST TACTILE CHARACTER NTS MIRROR A F B ED C 9'-0"PAINTED M.R. GYPSUM BOARD SCALE: 3/8" = 1'-0"A-3.0 A PAINTED M.R. GYPSUM BOARD 9'-0"C ED SCALE: 3/8" = 1'-0"A-3.0 B PAINTED M.R. GYPSUM BOARD 9'-0"C ED SCALE: 3/8" = 1'-0"A-3.0 C G STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) SCALE: 1/2" = 1'-0" 1 A-3.0 5'-11"7'-2 1/4"7'-2 1/4"A B C D E F G A B C D E F B A-3.0 A A-3.0 RESTROOM MEN'S 111 RESTROOM WOMEN'S 112 C A-3.0 A A-3.0 NORTH 1'-8"1'-8"3/4"1'-8" 2'-1"42"5" VINYL BASE 3-5/8" 25 GA. MTL. STUDS @ 16" O.C.COUNTER HEIGHT3/4"8"5/8" GYP. BD. W/ FRP-1 (2) 2 X 4 TOP PLATE VINYL BASE 3-5/8" 25 GA. MTL. STUDS @ 16" O.C. RUNNER TRACK SAME GA.AS STUDS.SECURE TO SLAB W/ 3/4" POWER DRIVEN PIN @ 16" O.C. WILSONART CLOUDS REST Q4049 QUARTZ COUNTERTOP W/ EASED EDGE ON 3/4" PLYWOOD PLYWD. WEB FRAME 48" O.C.COUNTER HEIGHT3'-3"34"3/4"42"1'-8"8"STAINED WOOD VENEER OVER 3/4" PLYWOOD, OWNER TO SELECT FINAL FINISH 5/8" GYP. BD. W/ FRP-1 (2) 2 X 4 TOP PLATE VINYL BASE 3-5/8" 25 GA. MTL. STUDS @ 16" O.C. RUNNER TRACK SAME GA.AS STUDS.SECURE TO SLAB W/ 3/4" POWER DRIVEN PIN @ 16" O.C.COUNTER HEIGHT3/4"FIN. FLR.34"BASE - SEE SCHED. 2'-1" COUNTERTOP 2" GROMMET - SEE PLAN FOR LOCATIONS ADA MTL. BRACKETS - AS REQ'D (PROVIDE BLOCKING)4"WILSONART CLOUDS REST Q4049 QUARTZ COUNTERTOP & BACKSPLASH OVER 1/2" PLYWD. STAINED WOOD VENEER OVER 3/4" PLYWOOD, OWNER TO SELECT FINAL FINISH WILSONART CLOUDS REST Q4049 QUARTZ COUNTERTOP W/ EASED EDGE ON 3/4" PLYWOOD PLYWD. WEB FRAME 48" O.C. WILSONART CLOUDS REST Q4049 QUARTZ COUNTERTOP W/ EASED EDGE ON 3/4" PLYWOOD PLYWD. WEB FRAME 48" O.C. FOOT REST - 3-5/8" 25 GA MTL. STUDS @16" O.C.8"STAINED WOOD VENEER OVER 3/4" PLYWOOD, OWNER TO SELECT FINAL FINISH 5/8" GYP. BD. W/ FRP-1 (2) 2 X 4 TOP PLATE RUNNER TRACK SAME GA.AS STUDS.SECURE TO SLAB W/ 3/4" POWER DRIVEN PIN @ 16" O.C. FOOT REST - 3-5/8" 25 GA MTL. STUDS @16" O.C. 1'-8" 3 5/8"STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) SCALE: 3/8" = 1'-0" 1 A-4.0 3'-3"3'-4"1'-4"3'-4"2'-9"23'-8"2'-1"3'-7"2'-0"A-4.0 A A-4.0 C A-4.0 B A-4.0 D A A-4.0 SCALE: 3/4" = 1'-0" B A-4.0 SCALE: 3/4" = 1'-0" C A-4.0 SCALE: 3/4" = 1'-0" D A-4.0 SCALE: 3/4" = 1'-0" NORTH FINISH NOTES: OWNER TO VERIFY & APPROVE ALL FINISHES PRIOR TO ANY ORDER GENERAL NOTES: -G.C. TO COORDINATE GROMMET CUT OUTS ALONG COUNTER TOP FOR POWER AS REQUIRED. OUTLETS TO BE CONCEALED W/ POP UP ABILITY AS APPROVED BY OWNER. -G.C. & OWNER TO APPROVE SHOP DWGS PRIOR TO FABRICATION. 1 1 02/08/22 REMOVED DRIVE-THRU WINDOW, BOLLARD, & CANOPY. SCALE: 3/8" = 1'-0" PAINTED HOLLOW METAL FRAME SEE SCHED.SEE SCHEDULE2"2"2"A SEE SCHED.SEE SCHEDULEFCG-1 ALUMINUM TRAFFIC DOOR B STAINLESS STEEL KICK PLATE BOTH SIDES - SEE SPECS BELOW WINDOW - SEE SPECS. BELOW ELIASON DOUBLE ACTING DOOR - SEE SPECS. BELOW SCALE: 3/8" = 1'-0" A SEE SCHEDULE SEE SCHEDULEPAINTED HOLLOW METAL DOOR DOOR - SEE SCHEDULE SCALE: 1 1/2" = 1'-0" 1 A-6.0 2 A-6.0 3 A-6.0 H.M. FRAME JAMB ANCHORS DOOR - SEE SCHEDULE CAULK (TYP.) (2) 3-5/8" MTL. STUDS SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" EXIST. CONC. SLAB FINISH FLOOR H.M. FRAME DOOR - SEE SCHEDULE CAULK (TYP.) 20 GA. 3-5/8" MTL. TRACK DOOR - SEE SCHEDULE SCALE: 1 1/2" = 1'-0" 4 A-5.0 5 A-5.0 6 A-5.0 H.M. FRAME DOOR - SEE SCHEDULE CAULK (TYP.) (2) 3-5/8" MTL. STUDS SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" EXIST. CONC. SLAB FINISH FLOOR H.M. FRAME DOOR - SEE SCHEDULE CAULK (TYP.) 20 GA. 3-5/8" MTL. TRACK STATE O F F LO R I D AREGI S RE D A R C H ECTE ITTTHO M A DU K E S EDWIN AR0013266 PERMIT ISSUE: (12/14/21) FINISH NOTES: 1. PROVIDE TRANSITION STRIP BETWEEN DIFFERENT FLOOR FINISHES (TYP). DOOR & HARDWARE NOTES: 1. PROVIDE LEVER-TYPE COMMERCIAL GRADE ACCESSIBLE HARDWARE ON ALL DOORS. PROVIDE DOOR STOPS AND SILENCERS FOR ALL DOORS AND FRAMES. 2. USE EQUIVALENT WHEN NECESSARY. 3. VERIFY KEYING REQUIREMENTS WITH TENANT & LANDLORD. MANUFACTURERS LOCKSET'S & CYLINDERS SCHLAGE CLOSERS DOR-O-MATIC BUTT HINGES STANLEY EXIT DEVICES & REMOVABLE MULLIONS MONARCH STOPS, SILENCERS , PULLS, PROTECTION ROCKWOOD PLATES & FLUSH BOLTS THRESHOLDS & WEATHERSTRIPPING PEMKO MARK ROOM NAME FLOOR BASE WALLS CEILING REMARKSNORTHEASTSOUTHWESTMAT.HT. 101 ENTRY S.C.B-1 --P-1 P-1 GWB 11'-11" 102 HOSTESS S.C.B-1 P-2 --P-1 GWB 11'-11" 103 SEATING AREA S.C.B-1 -P-1 P-1 -GWB 11'-11" 104 SALES FLOOR S.C.B-1 P-1 -P-1 P-1 GWB 11'-11" 105 BAR F-1 B-1 P-1 P-1 --GWB/C.T.VARIES SUSPENDED METAL CEILING TILE GRID SYSTEM. SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE INSTALL. EXIST. GWB ABOVE @ 11'-11" A.F.F. 106 PREP AREA F-1 B-1 P-1 P-1 P-1 P-1 GWB 11'-11" 107 WALK IN COOLER S.C.B-1 P-1 -P-1 P-1 GWB 11'-11" 108 OFFICE S.C.B-1 P-1 P-1 P-1 P-1 GWB 11'-11" 109 CORRIDOR S.C.B-1 P-1 P-1 -P-1 GWB 11'-11" 110 MEN'S RESTROOM S.C.B-1 P-1 P-1 P-1 P-1 GWB 9'-0" 111 WOMEN'S RESTROOM S.C.B-1 P-1 P-1 P-1 P-1 GWB 9'-0" DR. NO. DR. TYPE FRM. TYPE OPENING SIZE DOOR THICK. DR. MAT. FRAME MAT. DETAILS HDWR GRP.REMARKSWIDTHHEIGHTHEADJAMBTHRESHOLD 101 EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST. 103 EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST. ADD PANIC HARDWARE 106 B A 3'-0"7'-0"1-1/2"ALUM HM 4 5 6 1 108A EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXISTING INSWING DOOR TO BE MODIFIED TO OUTSWING. REUSE OR REPLACE EXISTING HARDWARE & FRAME AS REQUIRED. 108B A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 2 108C A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 2 109 EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXISTING INSWING DOOR TO BE MODIFIED TO OUTSWING. REUSE OR REPLACE EXISTING HARDWARE & FRAME AS REQUIRED. 110 A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 3 111 A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 3 MARK ITEM MANUFACTURER COLOR / MODEL REMARKS B-1 VINYL BASE FLEXCO 4" HIGH GROVE - COLOR TO BE SELECTED BY OWNER P-1 & P-2 PAINT SHERWIN WILLIAMS COLOR TO BE SELECTED BY OWNER S.C.SEALED CONCRETE INCRETE SUN BUFF - 840 SEE FINISH NOTES BELOW FOR SEALANT C.T.CEILING TILE SELECTED BY OWNER SELECTED BY OWNER SUSPENDED METAL CEILING TILE SYSTEM, SELECTED & PROVIDED BY OWNER. G.C. TO COORDINATE INSTALL. F-1 RUBBER FLOOR FLEXCO RADIAL LOW PROFILE RLT ALUM.ALUMINUM AL/GL ALUMINUM / GLASS H.M.HOLLOW METAL WD.WOOD WD/GL WOOD / GLASS NOTES: * SEE PAINT SCHEDULE BELOW. PAINT SCHEDULE INTERIOR FINISHES DRYWALL WALLS, COLUMNS AND CEILINGS PRIMER: B51W08670 - QUICK DRY INTERIOR/EXTERIOR STAIN BLOCKING PRIMER WHITE 2 COATS: COLOR TO BE SELECTED & PROVIDED BY OWNER DRYWALL WALLS AND CEILINGS IN RESTROOMS PRIMER: B51W08670 - QUICK DRY INTERIOR/EXTERIOR STAIN BLOCKING PRIMER WHITE 2 COATS: COLOR TO BE SELECTED & PROVIDED BY OWNER HOLLOW METAL DOORS AND FRAMES PRIMER: B66W00310 - PRO INDUSTRIAL PRO-CRYL® UNIVERSAL ACRYLIC PRIMER OFF WHITE 2 COATS: COLOR TO BE SELECTED & PROVIDED BY OWNER P-5 EXPOSED CEILING STRUCTURES SPOT PRIME: B66W00310 - PRO INDUSTRIAL PRO-CRYL® UNIVERSAL ACRYLIC PRIMER OFF WHITE FINISH: COLOR TO BE SELECTED & PROVIDED BY OWNER SEALED CONCRETE PRIMER: B65C775 - ARMORSEAL 1K WATERBASED URETHANE FLOOR ENAMEL (1 COAT W/ 10% WATER REDUCTION) FINISH: B65C775 - ARMORSEAL 1K WATERBASED URETHANE FLOOR ENAMEL SET 1: EACH DOOR TO HAVE ELIASON EASY SWING® HINGE SYSTEM SET 2: EACH DOOR TO HAVE 1 OFFICE LOCKSET AL53S JUP X 11-096 X 10-025 US 26D 3 EA. BUTTS F179 US 26D 4 1/2" X 4 1/2" NRP 1 STOP 443 26D 3 SILENCERS 608 1 CLOSER SC61 X 689 X SNB SET 3: EACH DOOR TO HAVE 1 PRIVACY LOCKSET AL40S JUP X 11-116 X 10-025 US 26D 3 EA. BUTTS F179 US 26D 4 1/2" X 4 1/2" NRP 1 MOP PLATE 4 X 35 U532D 1 STOP 443 26D 3 SILENCERS 608 1 CLOSER SC61 X 689 X SNB