363 Atlantic Blvd Unit 2, 3 Valhalla Tap Room interior build out permit 2 of 5RELEASED FOR CONSTRUCTION: 14 DECEMBER 2021
PERMIT SET
1'-0"4'-0"1'-6"5'-0"4'-0"3'-0"5'-0"3'-6"1'-10"
3'-6"4'-6" PER FBC-A 2017 FIGURE 404.2.4.1
(A)
FRONT APPROACH,
PULL SIDE
(B)
FRONT APPROACH, PUSH SIDE
(C)
FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND A LATCH
(D)
HINGE APPROACH, PULL SIDE
(F)
HINGE APPROACH, PUSH SIDE
(E)
HINGE APPROACH, PULL SIDE 4'-0"(G)
HINGE APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND A LATCH
1'-10"
2'-0"4'-0"(H)
LATCH APPROACH,
PULL SIDE
2'-0"4'-6"(I)
LATCH APPROACH, PULL SIDE,
DOOR PROVIDED WITH CLOSER 3'-6"2'-0"
(J)
LATCH APPROACH,
PUSH SIDE
4'-0"2'-0"
(K)
LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
SCALE: 1/4" = 1'-0"
38. THESE DOCUMENTS ARE PREPARED FOR THE USE OF THE GENERAL
CONTRACTOR AND HIS SUBCONTRACTORS AND IN NO WAY, EITHER IN WHOLE OR
IN PART CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY CONTRACTOR
WITH REGARD TO CONSTRUCTION MEANS, METHODS OR TECHNIQUES.
ARCHITECT DOES NOT INTEND TO EXPRESS ANY OPINION, DIRECTION OR
INSTRUCTION OF ANY KIND WHATSOEVER AS TO THE MANNER IN WHICH THE
CONSTRUCTION WORK IS TO BE ACCOMPLISHED.
39. NOTICE OF DUTY OF COOPERATION: ACCEPTANCE OF THESE DRAWINGS AND
SPECIFICATIONS CONSTITUTES AN AGREEMENT FOR FUTURE COOPERATION
BETWEEN THE GENERAL CONTRACTOR AND DESIGN CONCEPTS. ALTHOUGH
ARCHITECT AND IT'S CONSULTANTS HAVE PERFORMED THEIR SERVICES WITH
DUE CARE AND DILIGENCE, THEY CANNOT GUARANTY PERFECTION. ANY
AMBIGUITY OR DISCREPANCY IN THE USE OF THESE DRAWINGS AND
SPECIFICATIONS SHALL BE REPORTED TO ARCHITECT IMMEDIATELY, FAILURE TO
COOPERATE SHALL BE SIMPLE NOTICE TO ARCHITECT AND SHALL RELIEVE
ARCHITECT FROM RESPONSIBILITY FOR ALL CONSEQUENCES RESULTING
THEREFROM. CHANGES MADE FROM THE DRAWINGS AND OR SPECIFICATIONS
WITHOUT THE CONSENT OF ARCH- TECT, ARE UNAUTHORIZED AND SHALL
RELIEVE ARCHITECT OF ANY RESPONSIBILITY FOR ALL CONSEQUENCES ARISING
OUT OF SUCH CHANGE(S).
40. EACH CONTRACTOR AND SUBCONTRACTOR PARTICIPATING IN THE
CONSTRUCTION OF THIS "TENANT'S SPACE" SHALL BE DULY LICENSED AND EACH
CONTRACT SHALL CONTAIN THE GUARANTEE OF THE CONTRACTOR AND THE
SUBCONTRACTOR FOR THE PORTION OF THE TENANT'S WORK.
41. THESE DOCUMENTS ARE THE PROPERTY OF ARCHITECT AND TENANT. NO
PART OF THESE DOCUMENTS (DRAWINGS AND SPECIFICATIONS) SHALL BE USED
FOR ANY OTHER PROJECT EXCEPT FOR THIS PROJECT WITHOUT THE PRIOR
WRITTEN CONSENT OF "ARCHITECT".
1. GENERAL: EXECUTE CLEANING DURING PROGRESS OF THE WORK, AND AT
COMPLETION OF THE WORK, AS REQUIRED BY GENERAL CONDITIONS.
2. DISPOSAL REQUIREMENTS: CONDUCT CLEANING AND DISPOSAL OPERATIONS
TO COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, REGULATIONS, AND
ANTI-POLLUTION LAWS.
3. PRODUCTS: USE ONLY THOSE CLEANING MATERIALS WHICH WILL NOT CREATE
HAZARDS TO HEALTH OR PROPERTY, AND WHICH WILL NOT DAMAGE SURFACES.
USE ONLY THOSE CLEANING MATERIALS AND METHODS RECOMMENDED BY THE
MANUFACTURER OF THE SURFACE MATERIAL TO BE CLEANED. USE CLEANING
MATERIALS ONLY ON SURFACES RECOMMENDED BY THE CLEANING MATERIAL
MANUFACTURER.
4. EXECUTION: THE GENERAL CONTRACTOR AND SUB-TRADES SHALL EXECUTE
PERIODIC CLEANING TO KEEP THE WORK, THE SITE, AND ADJACENT PROPERTIES
FREE FROM ACCUMULATIONS OF WASTE MATERIALS, RUBBISH, AND DEBRIS
RESULTING FROM CONSTRUCTION OPERATIONS. PROVIDE ON-SITE CONTAINERS
FOR THE COLLECTION OF WASTE MATERIALS, DEBRIS, AND RUBBISH. REMOVE
WASTE MATERIALS, DEBRIS, AND RUBBISH FROM THE SITE PERIODICALLY, AND
DISPOSE OF AT LEGAL DISPOSAL AREAS AWAY FROM THE SITE.
5. DUST CONTROL: CLEAN INTERIOR SPACES PRIOR TO THE START OF FINISH
PAINTING, AND CONTINUE CLEANING ON AN AS-NEEDED BASIS UNTIL PAINTING IS
FINISHED. SCHEDULE OPERATIONS SO THAT DUST AND OTHER CONTAMINANTS
RESULTING FROM CLEANING PROCESS WILL NOT FALL ON WET, NEWLY-COATED
SURFACES.
1. UPON COMPLETION OF WORK, CONTRACTOR WILL PROVIDE A BROOM CLEAN
AND MOPPED DOWN SPACE. ALL NEW RUBBER BASE SHALL BE FREE OF
CONSTRUCTION DUST, ALL CONVECTOR ENCLOSURES CLEANED DOWN AND
FREE OF ALL SHOE MARKS AND MATERIAL FRAGMENTS.
2. REMOVE GREASE, MASTIC, ADHESIVES, DUST STAINS, FINGERPRINTS, LABELS
AND OTHER FOREIGN MATERIALS FROM SITE EXPOSED INTERIOR AND EXTERIOR
SURFACES.
3. WASH AND SHINE GLAZING AND MIRRORS. POLISH GLOSSY SURFACES.
4. PRIOR TO FINAL COMPLETION OR OWNER OCCUPANCY, CONTRACTOR SHALL
CONDUCT AN INSPECTION OF SIGHT EXPOSED INTERIOR AND EXTERIOR
SURFACES, AND ALL WORK AREAS, TO VERIFY THAT THE ENTIRE WORK AREA IS
CLEAN.STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
1. ALL CONTRACTORS SHALL FULLY INVESTIGATE THE JOB SITE TO COMPARE THE CONTRACT
DOCUMENTS AND EXISTING CONDITIONS RELATING TO CONSTRUCTION OF NEW WORK AND
LABOR. THE CONTRACTOR SHALL INCLUDE COST FOR ALL WORK DESCRIBED IN THE
CONTRACT DOCUMENTS AND REQUIRED OR IMPLIED BY EXISTING CONDITIONS. THE
SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH AN
EXAMINATION HAS BEEN MADE, AND LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIAL
REQUIRED OR FOR DIFFICULTIES ENCOUNTERED, WHICH WOULD HAVE BEEN FORESEEN
HAD SUCH AN EXAMINATION BEEN MADE, WILL NOT BE RECOGNIZED.
2. THE CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND SHALL NOTIFY THE
ARCHITECT OF ANY CONFLICTS BETWEEN THE CONSTRUCTION PLANS AND EXISTING
CONDITIONS. THE CONTRACTOR SHALL ALSO NOTIFY THE ARCHITECT OF ANY
OMISSION OR CONFLICT IN THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE
EXECUTION OF THE WORK. ALL CONFLICTS SHALL BE RESOLVED PRIOR TO THE
INSTALLATION OF ANY WORK.
3. THE CONTRACTORS SHALL THOROUGHLY REVIEW THE EXISTING CONDITIONS
TO IDENTIFY THE IMPACT ON ANY EXISTING FUNCTION, AND SHALL COORDINATE
HIS WORK SCHEDULES PRIOR TO COMMENCEMENT OF NEW WORK WITH
ARCHITECT AND OWNER.
4. THE CONTRACTORS SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE
CONTROL OVER, ALL CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES AND
PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK REQUIRED
BY THE CONTRACT DOCUMENTS.
5. UNLESS SPECIFICALLY NOTED TO THE CONTRARY, ALL NEW WORK IS IN
CONTRACT. CONTRACTORS SHALL FURNISH ALL LABOR, MATERIALS,
EQUIPMENT AND SERVICES NECESSARY TO COMPLETE THE PROJECT OUTLINED
ON THIS SET OF PLANS OR REASONABLY INFERABLE FROM THEM.
6. THE CONTRACTORS SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE
AND LOCAL BUILDING CODES AND REQUIREMENTS.
7. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND
INSPECTIONS REQUIRED BY THE LOCAL AUTHORITIES DURING THE COURSE OF
THE WORK. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
VARIANCE WITH CODES IN FORCE. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR COMPLIANCE WITH ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE
PERFORMANCE OF THE WORK.
8. ALL CONTRACTORS SHALL PROVIDE AND MAINTAIN PROPER AND SAFE
WORKING CONDITIONS AT ALL TIMES INCLUDING BUT NOT LIMITED TO
APPROPRIATE TOOLS, EQUIPMENT, SCAFFOLDING, SHORING, ETC.
9. NO SUBSTITUTION OF MATERIALS AND/OR CONSTRUCTION ITEMS SPECIFIED
WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT.
ALTERNATE EQUAL MANUFACTURERS WILL BE CONSIDERED UP TO 10 DAYS
PRIOR TO BID, SO AN ADDENDUM CAN BE ISSUED. IF ITEM IS NOT APPROVED BY
WRITTEN ADDENDUM, IT WILL NOT BE ACCEPTED.
10. SUBSTITUTIONS WILL BE ALLOWED WHEN THE SPECIFIED ITEMS CANNOT BE
OBTAINED WITHIN THE CONTRACT TIME. SPECIFIED ITEMS ARE TO BE USED AS
A GUIDELINE FOR DESIGN. SAMPLES ARE TO BE SUBMITTED TO THE ARCHITECT
FOR APPROVAL BEFORE SUBSTITUTION.
11. EXTRA COSTS: THE OWNER'S WRITTEN AUTHORIZATION MUST BE OBTAINED
PRIOR TO THE ORDERING OF ANY MATERIALS, CONTRACTS, OR THE EXECUTION
OF ANY WORK IN EXCESS OF ORIGINAL CONTRACT.
12. ALL ADJACENT WORK SHALL BE PROTECTED FROM DAMAGE CAUSED BY THIS
WORK. ANY RECURRENT DAMAGE IS THE FINANCIAL RESPONSIBILITY OF THE
CONTRACTOR.
13. THE CONTRACTOR SHALL KEEP THE PROJECT SITE REASONABLY CLEAN AND
FREE FROM HAZARDS AT ALL TIMES. ALL EXISTING EGRESS REQUIREMENTS ARE
TO BE MAINTAINED. THE CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS,
BROOM CLEAN THE ENTIRE PROJECT AREA, AND LEAVE THE SITE IN A
REASONABLY CLEAN CONDITION DAILY, IN THE JUDGMENT OF THE BUILDING
MANAGEMENT.
14. TWO (2) WEEKS PRIOR TO COMPLETION, THE CONTRACTOR SHALL NOTIFY
THE ARCHITECT TO COMPLETE A PUNCH LIST OF CORRECTIONS.
15. ALL WORK SHALL COMPLY WITH GOOD TRADE PRACTICE, REGULATIONS OF
THE CITY, STATE AND FEDERAL GOVERNMENT AGENCIES HAVING
JURISDICTION.
16. CONTRACTOR SHALL INCLUDE IN BID THE REMOVAL OF DEBRIS AND
CLEANING AFTER ALL FINISH TRADES.
17. CONTRACTOR TO PREPARE ALL FLOORS FOR NEW FLOOR FINISHES AS
INDICATED ON PLAN.
18. VERIFY ALL DIMENSIONS IN THE FIELD. DO NOT SCALE DRAWINGS;
DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE
DETAILS.
19. SUBMIT FOR ARCHITECT'S REVIEW AND CONSIDERATION ALL BUILDING
SAMPLES, PRODUCT LITERATURE AND OTHER PERTINENT DATA OF ANY
PROPOSED SUBSTITUTIONS.
20. SUBMIT FOR ARCHITECT'S REVIEW PRIOR TO FABRICATION OR PURCHASE,
SHOP DRAWINGS, OR SAMPLES FOR ALL MILLWORK, CUSTOM METAL WORK,
INCLUDING CABINETRY, GLASS WALLS AND DOOR ASSEMBLIES AND ALL OTHER
ITEMS AS REQUIRED IN THE CONTRACT DOCUMENTS.
21. CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING WORK THAT
MAY BE REQUIRED TO MAKE ALL PARTS OF THE PROJECT COME TOGETHER
PROPERLY.
22. PROVIDE AND INSTALL ALL PARTITION DOORS AND BUCKS DESIGNATED ON
DRAWINGS.
23. PROVIDE SUFFICIENT FRAMING FOR ALL WALL OPENINGS REQUIRED BY
DUCTWORK AND RETURN AIR, BOTH ABOVE AND BELOW HUNG CEILING. THESE
ARE TO BE COORDINATED WITH HVAC ALTERATION DRAWINGS.
24. ALL PARTITIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS FOR DEFLECTIONS NOT TO EXCEED
L/240 OF THE SPAN.
25. CONTRACTOR SHALL REFER TO PARTITION TYPES FOR ACTUAL WALL
THICKNESS.
26. ALL DIMENSIONS SHOWN ARE FACE OF STUD OR MASONRY, UNLESS
OTHERWISE NOTED.
28. DIMENSIONS NOTED "+/-" ARE THE ONLY DIMENSIONS ADJUSTABLE WITHOUT
APPROVAL OF THE ARCHITECT.
30. ALL BUILDING COMPONENTS BELONG TO THE LANDLORD. COORDINATE
DEMOLITION, REMOVAL AND STORAGE OF ALL MILLWORK, DOOR FRAMES AND
FIXTURES, ETC. WITH LANDLORD.
31. CONTRACTOR SHALL INSPECT EXISTING DEMISING WALLS FOR ALL
PENETRATIONS AND SEALS. RETRO FIT ANY PENETRATIONS NOT CONFORMING
TO U.L. LISTINGS FOR WALLS AS RATED ON PLAN
33. ALL WORK AND MATERIALS USED TO ACCOMPLISH DESIGNATED WORK SHALL
BE COORDINATED WITH CONTRACTOR, TENANT REPRESENTATIVE (WHEN
APPLICABLE) AND BUILDING OWNER REPRESENTATIVE WITH RESPECT TO
DELIVERY AND STORAGE.
34. CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME
WITHOUT APPROVED CONTRACT DOCUMENTS.
35. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL ARCHITECTURAL,
MECHANICAL, TELEPHONE, ELECTRICAL (INCLUDING LIGHTING), AND PLUMBING
SO TO ENSURE THAT REQUIRED CLEARANCES FOR INSTALLATION AND
MAINTENANCE OF ALL EQUIPMENT ARE PROVIDED.
36. THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR IN PART
WITHOUT PRIOR WRITTEN CONSENT FROM "ARCHITECT".
37. THIS SET OF DOCUMENTS ARE CONSIDERED AS ONE UNIT AND SHALL NOT BE
CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY
MANNER. DOCUMENTS SHALL NOT BE SEPARATED FOR THE PURPOSES OF
SUBMITTING A BID PROPOSAL OR FOR THE SEPARATE PHASE OF ANY
CONSTRUCTION.
27. THE CONTRACTOR SHALL PROVIDE AND INSTALL BRACING AND BLOCKING AS
REQUIRED TO SUPPORT ANY WALL-MOUNTED FIXTURES, SHELVING, COUNTER
TOPS, CABINETS, ETC. ALL WOOD BLOCKING OR BRACING SHALL BE PRESSURE
TREATED, FIRE RETARDANT IN EXTERIOR WALLS AS REQUIRED.
29. THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE EXTINGUISHER
CABINET EQUIVALENT TO LARSEN ARCHITECTURAL SERIES SQUARE TRIM SEMI
RECESSED FULL GLASS CABINET WITH TYPE 3A:10B:C. FIRE EXTINGUISHER,
COLOR ALUMINUM. ALL EXTINGUISHERS SHALL BE SURFACE MOUNTED AT A
HEIGHT OF 48" ABOVE THE FINISHED FLOOR (TOP OF CABINET).
32. CONTRACTOR SHALL CONTROL NOISE PRODUCING ITEMS (STEREOS) AND
MAINTAIN @ APPROPRIATE LEVELS AT ALL TIMES. FOUL LANGUAGE, ABUSIVE
TALK, AND INAPPROPRIATE BEHAVIOR SHALL NOT BE TOLERATED.
R.
REINF.
REFR.
R.D.
RE:
RM
REQ'D.
R.M.O.
S
SCHED.
S.C.
S.F.
SECT.SECTION
RISER
REQUIRED
ROOM
SCHEDULE
SOUTH
SQUARE FOOT
SOLID CORE
REFER TO ...
ROOF DRAIN
REINFORCED
ROUGH MASONRY OPENING
REFRIGERATOR
SHT.
SIM.
S.S.
SQ. OR
STAGG.
STIFF
STRUC.
STL.
STD.
TR
T & B
T/
THK.
T & G
TER.
SUSP.
TYP.
SPEC.
STIFFENER
SUSPENDED
SIMILAR
SHEET
SQUARE
STEEL
STANDARD
TREAD
TOP OF
THICK
TERRAZZO
TYPICAL
TOP AND BOTTOM
TONGUE & GROOVE
STAGGERED
STAINLESS STEEL
STRUCTURAL
SPECIFICATION
I.D.
INSUL.
JAN.
INT.
KIT.
JST.
JNT.
LAV.
LAM.
LAB.
LT.
LAVATORY
LIGHT
INSULATION
JANITOR
INTERIOR
KITCHEN
JOIST
JOINT
LAMINATE
LABORATORY
F.D.C.
FDN.
ELEV.
EQUIP.
ENCL.
EMER
EQ.
E.W.
E.W.C.
EXP.
F.A.
F.D.
EXT.
FOUNDATION
EQUAL
EMERGENCY
FIRE ALARM
FLOOR DRAIN
EQUIPMENT
EXTERIOR
EACH WAY
EXPANSION
ENCLOSURE
ELEVATION
FIRE DEPARTMENT CONNECTION
ELECTRIC WATER COOLER
MAX.
MECH.
MIN.
MEMB.
MFR.
M.H.
MISC.
MTL.
MUL.
M.r.o.
NO.
N.I.C.
NOM.
N.T.S.
N
NOT TO SCALE
MISCELLANEOUS
MANUFACTURER
MAXIMUM
MINIMUM
MEMBRANE
MANHOLE
MULLION
METAL
NORTH
NOMINAL
NUMBER
MECHANICAL
F.E.
F.E.C.
FIN.
F.L.
F.H.C.
FND.
F.O.B.
FLUOR.
FLR.
FTG.
F.S.
FT.
GALV.
GA.
FURR.
F.O.C.
G.C.
F.F.
FIRE EXTINGUISHER
GENERAL CONTRACTOR
FIRE HOSE CABINET
FINISH
FLOOR
FOOTING
GAUGE
FURRING
GALVINIZED
FOUNDATION
FACE OF BRICK
FACE OF CONCRETE
FLUORESCENT
FOOT OR FEET
FULL SIZE
FLOW LINE
FINSH FLOOR
FIRE EXTINGUISHER CABINET
MASONRY rough O.
NOT IN CONTRACT
INSIDE DIAMETER
BLK'G.
BM.
ACT
AB.
AL.
AGGR.
A.F.F.
ARCH.
ALT.
APPROX.
BLK
BLDG.
BD.
BLOCKING
BEAM
ACOUSTICAL CEILING TILE
ABOVE FINISHED FLOOR
ANCHOR BOLT
BLOCK
BOARD
ARCHITECTURAL
APPROXIMATE
BUILDING
ALTERNATE
ALUMINUM
AGGREGATE
B.U.R.
BETWEEN.
CLG.
C.J.
C.M.U.
COL.
CLR.
CLKG.
CONN.
CONT.
DEG.
C.T.
DET./DTL.
CONSTR.
CONC.
B.W.
CONCRETE MASONRY UNIT
CEILING
CLEAR
COLUMN
DEGREE
DETAIL
BUILT UP ROOFING
CONTROL JT.
CONNECTION
CONSTRUCTION
CERAMIC TILE
CONCRETE
CONTINUOUS
CAULKING
BOTH WAYS
BETWEEN
BOT.BOTTOM
T.O.W.
T.O.C.
T.O.S.
U.N.O.
VERT.
VER
VCT
W
W/
W.C.
WD.
C
W/O
P
VERTICAL
VERIFY
WEST
WITH
WOOD
WITHOUT
L
L PLATE
TOP OF WALL
TOP OF CONCRETE
TOP OF STEEL
UNLESS NOTED OTHERWISE
VINYL COMPOSTION TILE
CENTERLINE
WATER CLOSET
OPG.
O.D.
OH.
PCT.
P.L.
OPP.
PLYWD.
PLAS.
PR.
Q.T.
P.LAM.
PROPERTY LINE
QUARRY TILE
OVERHEAD
OPENING
PRE-CAST
OPPOSITE
PLYWOOD
PLASTER
PAIR
G.W.B.
GR.
GYP.
H.C.
H.B.
GYP. BD.
H.M.
HDWE.
HDWD.
HT.
HVAC
HR.
H/C
GYPSUM WALL BOARD
GYPSUM
GRADE
HEIGHT
HOUR
HANDICAPPED
HOLLOW CORE
GYPSUM BOARD
HOLLOW METAL
AIR CONDITIONING
HARDWARE
HARDWOOD
HOSE BIBB
HEATING, VENTILATION AND
PLASTIC LAMINATE
OUTSIDE DIAMETER
DIAG.
DN.
DIA.
E
DS.
DWG.
E.J.
E.I.F.S.
EA.
(E)
ELEC.
EL. ELEV.
DOWN
EAST
EACH
ELECTRICAL
EXPANSION JOINT
ELEVATION
EXISTING
DIAGONAL
DIAMETER
DOWNSPOUT
DRAWING
D.F.DRINKING FOUNTAIN G.L.O.C.GLASS ON CENTER
LOCATION
SITE
DETAIL REFERENCE
SECTION REFERENCE
COLUMN LINE NUMBER
ELEVATION REFERENCE
WHICH DETAIL APPEARS
INDICATES SHEET UPON
INDICATES DETAIL NUMBER
OR
ELEVATION
DOOR NUMBER
EXTERIOR INSULATION
AND FINISH SYSTEM
ABBREVIATIONS NOT LISTED.
NOTE: CLARIFY WITH ARCHITECT ALL
NORTH
R.O.ROUGH OPENING
M.O.MASONRY OPENING
1
RM NAME
RM #
62'-6 5/16"DIAGONAL DISTA
NCE 53'-0
1
/2"
MAX TRAVEL DIST.
TO EXIT 69'-8"SEPARATIONOF EX
ITS
MAX COMMON
PATH OF
TRAVEL 50'-4"
ENTRY
101
HOSTESS
102
SALES FLOOR
104
SEATING AREA
103
BAR
105
PREP AREA
106
WALK IN COOLER
107
OFFICE
108
CORRIDOR
109
RESTROOM
WOMEN'S
111
RESTROOM
MEN'S
110
KEY PLAN
SUITE '2'&'3'
SCALE: 1/4" = 1'-0"STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)NORTH
NOTES:
1. CONTRACTOR SHALL PROVIDE TACTILE SIGNAGE PER NFPA 101
7.10.1.3. READING "EXIT" AT ALL EXTERIOR DOORS.
2. CONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE DISCONNECT &
SIGNAGE PER NFPA 70 230.70 & NFPA 1 11.1.7.
3. ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN
ACCORDANCE WITH NFPA 101 SECTION 7.8 AND FBC 1008.3.
4. ALL NEW INTERIOR FINISHES SHALL COMPLY WITH NFPA 101 10.2 AND
FBC 803 & 804
FLORIDA BUILDING CODE 7TH EDITION (2020)
FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020)
FLORIDA BUILDING CODE MECHANICAL 7TH EDITION (2020)
FLORIDA BUILDING CODE PLUMBING 7TH EDITION (2020)
NATIONAL ELECTRIC CODE / NFPA 70 NEC (2017)
FLORIDA BUILDING CODE FUEL GAS 7TH EDITION (2020)
FLORIDA EXISTING BUILDING CODE 7TH EDITION (2020)
FLORIDA ACCESSIBILITY CODE 7TH EDITION (2020)
FLORIDA BUILDING CODE ENERGY CONSERVATION 7TH EDITION (2020)
1.SCOPE OF PROJECT INVOLVES A LEVEL II ALTERATION OF A 1,917 S.F. INTERIOR
TENANT BUILD OUT FOR A NEW TAVERN. WORK INCLUDES NEW MECHANICAL,
ELECTRICAL, AND PLUMBING; NEW BATHROOMS, PREP AREA, ACCESSORY
OFFICE, SEATING AREA, AND FINISHES THROUGHOUT.
2.TO THE BEST OF OUR KNOWLEDGE, INFORMATION, AND INTENT, BUILDING
ALTERATIONS WERE DESIGNED TO AND COMPLY WITH THE APPLICABLE CODES
LISTED ABOVE.
3.INSPECTION OF EXISTING RATED WALLS BY ARCHITECT IS A LIMITED
OBSERVATION AND DOES NOT CONFIRM THE ENTIRE EXISTING ASSEMBLY
CONDITION. ADDITIONAL WORK MAY BE REQUIRED IF, DURING ANY
CONSTRUCTION PHASE, THE WALL/CEILING IS DETERMINED TO BE DEFICIENT
INCLUDING BUT LIMITED TO:
A. FIRE CAULK ALL PIPE PENETRATIONS PER
UL W-L-1054 FOR METAL PIPES AND UL W-L-2098 FOR PVC.
B. SEAL WALL TO METAL DECK PER UL U-379 REQUIREMENTS.
C. FILL ANY HOLES IN WALL MISSING GWB WITH 5/8"
FIRE RATED GWB PER UL U-379 REQUIREMENTS.
4.ALL VISIBLE EMERGENCY LIGHTS AND EXIT SIGNS OBSERVED ARE INDICATED
ON PLAN. OWNER SHALL PROVIDE ADDITIONAL FIXTURES AS INDICATED ON LIFE
SAFETY PLAN AND REQUIRED BY AHJ.
5.OWNER SHALL VERIFY BATTERY BACKUP CIRCUITS ARE PRESENT & MEET THE
REQUIREMENTS OF NFPA 101 7.8 AND FBC 1008.3. PROVIDE IS NECESSARY.
NORTH
FIRE EXTINGUISHER
EXIT LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE
EXIT / EMERGENCY LIGHT FIXTURE COMBO
1 HOUR RATED PARTITION
2 HOUR RATED PARTITION
LIGHT HAZARD
OFFICES, CLASSROOMS, CHURCHES, ASSEMBLY HALLS, HOTEL OR MOTEL
GUESTROOMS, ETC.
ORDINARY HAZARD
DINING AREAS, MERCANTILE SHOPS AND ALLIED STORAGE, LIGHT
MANUFACTURING, RESEARCH OPERATIONS, AUTO SHOWROOMS,
PARKING GARAGES, WORKSHOP OR SUPPORT SERVICE AREAS OF LIGHT
HAZARD OCCUPANCIES AND WAREHOUSES CONTAINING NFPA 13 CLASS I
OR CLASS II COMMODITIES.
EXTRA HAZARD
WOOD WORKING, VEHICLE REPAIR, AIRCRAFT AND BOAT SERVICING,
COOKING AREAS, INDIVIDUAL PRODUCT DISPLAY SHOWROOMS, PRODUCT
CONVENTION CENTER DISPLAYS AND STORAGE AND MANUFACTURING
PROCESS SUCH AS PAINTING, DIPPING, AND COATING INCLUDING
FLAMMABLE LIQUID HANDLING. WAREHOUSING OR IN‐]PROCESS
STORAGE OF OTHER THAN NFPA 13 CLASS I OR CLASS II COMMODITIES.
PORTABLE FIRE EXTINGUISHERS
MAXIMUM PROTECTED AREA
2A-10B:C LIGHT A = 3,000 SF
2A-10B:C 3,000 ORDINARY A = 1,500 SF
3A-40B:C 9,000 LIGHT
3A-40B:C 4,500 ORDINARY
4A-80B:C 11,250 LIGHT
4A-80B:C 6,000 ORDINARY
4A-80B:C 4,000 EXTRA A = 1,000 SF
MIN. PLUMBING FACILITIES REQ'D.
OCCUPANCY AND CONSTRUCTION TYPE
(BASED ON HIGHER SEAT COUNT) EXITS
TRAVEL DISTANCE
SEPARATION REQUIREMENTS
FIRE RATED SEPARATION REQ'D BETWEEN ASSEMBLY AND BUSINESS
OCCUPANCIES
2-HR SEPARATION, PER FBC TABLE 508.4
OCCUPANCY TYPE:
'A-2' ASSEMBLY PER FBC 303.3
CONSTRUCTION TYPE:
'IIIA' PER FBC TABLE 601, NON-SPRINKLERED
TOTAL AREA: 1,917 G.S.F.
EXIT UNITS REQ'D = 64 X .2" = 12.8 (32" MIN)
2 EXITS REQUIRED PER FBC TABLE 1006.3.1
PROVIDED 3 EXITS = 99" TOTAL EXIT UNITS
MIN. SEPARATION BETWEEN EXITS
≥1/2 MAX. DIAGONAL DISTANCE PER FBC 1007.1.1
MIN. SEPARATION REQUIRED: 1/2 X 62'-6" = 31'-3" , (ACTUAL) = 53'
GROUP 'A-2' ASSEMBLY, NON-SPRINKLERED
MAXIMUM COMMON PATH OF TRAVEL ALLOWED:(ACTUAL) = 50'-4"
75'-0" PER FBC TABLE 1006.2.1
MAXIMUM TRAVEL DISTANCE ALLOWED:(ACTUAL) = 69'-8"
200'-0" PER FBC TABLE 1017.2
MAXIMUM DEAD END CORRIDOR DISTANCE ALLOWED:(ACTUAL) = 0
20'-0" PER FBC 1020.4
OCCUPANCY AND CONSTRUCTION TYPE
(BASED ON HIGHER SEAT COUNT) EXITS
TRAVEL DISTANCE
SEPARATION REQUIREMENTS
FIRE RATED SEPARATION REQ'D BETWEEN ASSMEBLY AND BUSINESS
OCCUPANCIES
2-HR SEPARATION, PER NFPA 101 TABLE 6.1.14.4.1(A)
OCCUPANCY TYPE:
ASSEMBLY PER NFPA 101 6.1.2
CONSTRUCTION TYPE:
'III211' PER NFPA 220 4.4, NON-SPRINKLERED
TOTAL AREA: 1,917 G.S.F.
EXIT UNITS REQ'D = 69 X .2" = 13.8 (32" MIN)
2 EXITS REQUIRED PER NFPA 101 7.4.1.1
PROVIDED 3 EXITS = 99" TOTAL EXIT UNITS
MIN. SEPARATION BETWEEN EXITS
≥1/2 MAX. DIAGONAL DISTANCE PER NFPA 101 7.5.4.2
MIN. SEPARATION REQUIRED: 1/2 X 62'-6" = 31'-3" , (ACTUAL) = 53'
GROUP 'A-2' ASSEMBLY, NON-SPRINKLERED
MAXIMUM COMMON PATH OF TRAVEL ALLOWED:(ACTUAL) = 50'-4"
20'-0" (SERVING > 50 OCC.) PER NFPA 101 12.2.5.1.2
75'-0" (OCC. LOAD ≤ 50), PER NFPA 101 12.2.5.1.2
MAXIMUM TRAVEL DISTANCE ALLOWED:(ACTUAL) = 69'-8"
200'-0" PER NFPA 101 12.2.6.2
MAXIMUM DEAD END CORRIDOR DISTANCE ALLOWED:(ACTUAL) = 0
20'-0" PER NFPA 101 12.2.5.1.3
64 OCCUPANTS: 32 FEMALES / 32 MALES
W.C. - REQ'D. - 1 PER 40
32 FEMALES = 1 REQ'D - PROVIDED: 1
32 MALES = 1 REQ'D - PROVIDED: 1
LAV. - REQ'D. - 1 PER 75
32 FEMALES = 1 REQ'D - PROVIDED: 1
32 MALES = 1 REQ'D - PROVIDED: 1
**D.F. - 0 REQ'D
SERVICE SINK -1 REQ'D - PROVIDED: 1 PER FBC, PLUMBING TABLE 403.1
EXIT:
CLEAR WIDTH: 33"
CAPACITY: 165 OCC.
EXIT:
CLEAR WIDTH: 33"
CAPACITY: 165 OCC.
EXIT:
CLEAR WIDTH: 33"
CAPACITY: 165 OCC.
OCCUPANT LOAD - FBC
TABLE 1004.5
ROOM USE AREA SF
SF/
OCC._
TOTAL
OCC
ENTRY WAITING AREA 86 15 GROSS 5.7
HOSTESS BUSINESS 53 150 GROSS 0.4
SEATING AREA
UNCONCENTRATED
(TABLES & CHAIRS)471 15 NET 31.4
SALES FLOOR MERCANTILE 146 60 GROSS 2.43
BAR SEATING LINEAR INCHES 372 18
LINEAR
INCHES 20.67
BAR BUSINESS 187 150 GROSS 1.25
PREP AREA/COOLER COMMERCIAL KITHCEN 302 200 GROSS 1.5
OFFICE BUSINESS 134 150 GROSS 0.89
TOTAL 63.3
OCCUPANT LOAD -NFPA
101 TABLE 7.3.1.2
ROOM USE AREA SF
SF/
OCC.
TOTAL
OCC
ENTRY WAITING AREA 86 15 5.7
HOSTESS BUSINESS 53 150 0.4
SEATING AREA
UNCONCENTRATED (TABLES
& CHAIRS)471 15 31.4
SALES FLOOR MERCANTILE 146 30 4.87
BAR SEATING LINEAR INCHES 372 18 20.67
BAR BUSINESS 187 150 1.25
PREP AREA/COOLER COMMERCIAL KITHCEN 302 100 3.02
OFFICE BUSINESS 134 150 0.89
TOTAL 68.2
F.E.
EXISTING DEMISING WALL. 2-HR
FIRE RATING REQUIRED. G.C. TO
VERIFY CONDITION. SEE NOTE TO
PLAN REVIEWER #3
EXISTING CMU EXTERIOR WALL
F.E.
TOTAL OCCUPANTS 64 TOTAL OCCUPANTS 69
**DRINKING FOUNTAIN NOT REQUIRED PER FBC-P 410.4
(RESTAURANTS SERVING WATER IN CONTAINER FREE OF CHARGE)
N.T.S.
1
1 02/08/22 REMOVED DRIVE-THRU WINDOW,
BOLLARD, & CANOPY.
1
1
1
1
1
1
1
1
1
1
1
1
2 2
33
4
44
5 5
KEY PLAN
SUITE '2'&'3'
1 REMOVE ALL INTERIOR PARTITIONS, CEILINGS,
LIGHTING, FLOOR FINISHES AS REQUIRED FOR
NEW WORK.
REMOVE EXISTING PLUMBING FIXTURES, AND
FINISHES AS REQUIRED FOR NEW WORK. GWB
CEILING TO REMAIN.
EXISTING INSWING DOOR TO BE MODIFIED TO
OUTSWING. REUSE OR REPLACE EXISTING
HARDWARE & FRAME AS APPLICABLE. GC TO
COORDINATE.
REMOVE EXISTING MILLWORK
REMOVE & RELOCATE ELECTRICAL PANEL. SEE
ELECTRICAL DWG FOR DISTRIBUTION.
2
3
4
5
1.REMOVE ALL EXISTING CONSTRUCTION AS REQUIRED FOR
NEW CONSTRUCTION.
2.PATCH AND REPAIR ALL WALLS AND RELATED FINISHES
ADJACENT TO AREAS OF DEMOLITION, WHERE DEMOLITION
AFFECTED THE EXISTING FINISHES.
3.CONTRACTORS SHALL COORDINATE THE SEQUENCE FOR
DEMOLITION.
4.REMOVE ALL CONSTRUCTION SHOWN ON THE DRAWINGS AS
EXISTING TO BE REMOVED, INCLUDING, BUT NOT LIMITED TO:
PARTITIONS, HANGERS, STRAPS AND OTHER ACCESSORY
OBJECTS CONNECTED WITH THE ITEMS BEING REMOVED.
5.WHERE WATER LINES OR DRAINS TO EXISTING PLUMBING
FIXTURES ARE DISCONNECTED AND NOT REUSED. THEY SHALL
BE CAPPED AT THE TAP CONNECTION, AND ADEQUATELY
RECESSED TO ACCOMMODATE PATCHING OF FINISHED WALL
OR FLOOR FOR A SMOOTH FLUSH APPEARANCE.
6.THE DISCONNECT OF ALL ELECTRICAL DEVICES REMOVED
SHALL BE AT THE SUPPLY JUNCTION BOX OUTLETS AND
SWITCHES SHALL BE STORED ON SITE FOR REUSE WHERE
FEASIBLE.
7.NEWLY ABANDONED OR EXISTING ABANDONED PLUMBING
WHICH IS EXPOSED SHALL BE CUT, CAPPED AND ADEQUATELY
RECESSED TO ACCOMMODATE PATCHING OF FINISHED WALL
FLOOR OR CEILING FOR A SMOOTH FLUSH APPEARANCE.
8.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
PROVIDING ADEQUATE DUST PROTECTION TO KEEP ALL DUST
& DEBRIS SEPARATED FROM HVAC SYSTEM AND NON
CONSTRUCTION AREAS. TEMPORARY BARRIER WALLS AND
DUST PROTECTION SHALL REMAIN UNTIL ALL WORK AND
CLEAN UP IS FINAL. CONTRACTOR SHALL SUBMIT DUST
MAINTENANCE PLANS AND PROCEDURES TO TENANT FOR
APPROVAL PRIOR TO START OF CONSTRUCTION.
9.GENERAL CONTRACTOR IS TO EXPLORE SITE AND BUILDING
AND NOTIFY ARCHITECT OF ANY POSSIBLE PROBLEMS OR
DRAWING EXCLUSIONS PRIOR TO COMMENCING WITH
PROJECT.
10.SEE CIVIL PLANS FOR ADDITIONAL EXTERIOR DEMOLITION
WORK AS REQUIRED.
EXISTING WALLS TO REMAIN
EXISTING WALLS TO BE DEMOLISHED
STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
SCALE:1/4"=1'-0"
NORTH
NORTH
NOTE:
DEMOLITION SHEET INCLUDED
FROM PREVIOUSLY SUBMITTED
DEMOLITION PERMIT SET.
3
4
11
55 6
7
8
9
10
11
11
12
13
14 14
15
16
16
1616
171841
1920
2122
23 232424242525
26
27
27
27 27 27 27
28
29
30
31
32
33
34
34
35
35
35
13'-10 1/4"27'-7 3/4"12'-0 1/4"
6'-3 1/4"
26
5'-9"18'-7 3/8"5'-4 7/8"3'-7 1/2"8'-7 7/8"7'-5 1/8"10'-2 1/2"15'-5"2'-0"6'-9 1/2"2'-1"22'-0 1/2"ENTRY
101
HOSTESS
102
SALES FLOOR
104
SEATING AREA
103
BAR
105
PREP AREA
106
WALK IN COOLER
107
OFFICE
108
9'-0 3/8"18'-7 3/8"5'-9"6'-3 1/4"7'-0"2'-0"4'-10 1/4"19'-7 3/4"7'-7 1/8"7'-2 7/8"30
CORRIDOR
109
RESTROOM
WOMEN'S
111
RESTROOM
MEN'S
110
3
33
1
1
1
1
2
1
32
3
3
1
A-3.0
3'-0"9'-0 1/4"1'-0"8'-0"
2'-0"10'-0"2'-6"
2'-6"2'-6"
9'-5"2'-4 1/2"7'-10"10'-2"1'-6"1'-6"3'-6 1/4"110
111 108B
108A
108C
109
106
103101
1
A-4.01'-0"38 49'-8"EXISTING COVERED WALKWAY48'-4"39 40
3
KEY PLAN
SUITE '2'&'3'
1 NEW OUTSWING DIRECTION. PER DEMO PLAN.
3 NEW ELECTRICAL PANEL LOCATION - SEE
ELECTRICAL DWGS.
(FUTURE) 100LBS CO2 TANK LOCATION4
DESK SELECTED & PROVIDED BY OWNER5
MOP SINK - SEE PLUMBING DWGS.6
AVANTCO A-19R-HC 29" REFRIGERATOR OR
EQUIVALENT
7
REGENCY 24" X 24" NSF WIRE 5-SHELF OR
EQUIVALENT
8
REGENCY 41" TWO COMPARTMENT SINK OR
EQUIVALENT
9
REGENCY 30" X 72" SS WORK TABLE OR
EQUIVALENT
10
PANASONIC NE-SCV22NAPR COUNTERTOP
MICROWAVE CONVECTION OVEN OR EQUIVALENT
11
STORAGE SHELF SELECTED & PROVIDED BY
OWNER
12
BEER RACK SELECTED & PROVIDED BY OWNER13
KEG RACK SELECTED & PROVIDED BY OWNER14
8'Wx18'Dx8'H BARR WALK-ON COOLER. G.C. TO
COORDINATE INSTALL
15
CLOVER POINT OF SALE SYSTEM SELECTED AND
PROVIDED BY OWNER
16
UNDER COUNTER COOLER - ARCTIC AIR ABB72G
72" OR EQUIVILANT
17
ROYAL INDUSTRIES WT 3624 36" WORK TABLE
(OR EQUIVALENT)
18
MOTAK DISH DSP3 UNDER COUNTER GLASS
WASHER OR EQUIVALENT
21
STEELTON 3 BOWL UNDER BAR SINK OR
EQUIVALENT
22
AMERICAN BEVERAGE GLASS RINSER DRIP TRAY
OR EQUIVALENT
23
ADVANCE TABCO EDC-1548 48" DISH CABINET OR
EQUIVALENT
24
WALL MOUNT 12 FAUCET DISPENSER AIR
COOLED OR EQUIVALENT
25
PROCOOL CST-2000 3 DOOR BEVERAGE COOLER
OR EQUIVALENT
26
BEER DISPLAY RACK SELECTED & PROVIDED BY
OWNER
27
MERCHANDISE DISPLAY SHELVES SELECTED &
PROVIDED BY OWNER
28
RECEPTION COUNTER W/ MERCHANDISE
DISPLAY BELOW SELECTED & PROVIDED BY
OWNER. G.C. TO INSTALL
29
COUNTER TO BE ADA HEIGHT PER FBC -
ACCESSIBILITY 226 THAT COMPLY WITH FBC -
ACCESSIBILITY 902
30
COMMUNITY TABLE & CHAIRS SELECTED &
PROVIDED BY OWNER
31
HIGH TOP TABLE & CHAIRS SELECTED &
PROVIDED BY OWNER
32
DINING TABLES TO BE ADA HEIGHT PER FLORIDA
BUILDING CODE - ACCESSIBILITY 226 THAT
COMPLY WITH FLORIDA BUILDING CODE -
ACCESSIBILITY 902. PROVIDED BY OWNER
33
LEATHER LOUNGE COUCH SELECTED & PROVIDED
BY OWNER
34
LOUNGE TABLE & CHAIRS SELECTED &
PROVIDED BY OWNER
35
BAR STOOLS SELECTED & PROVIDED BY OWNER38
REGENCY 15" X 36" 304 STAINLESS STEEL DISH
CABINET W/ INNOVECO CO2 GLASS CHILLER, OR
EQUIVALENT. PROVIDED BY OWNER.
39
20 LBS C02 TANK. PROVIDED BY OWNER.40
SPLASH WM900 12"W WALL MOUNT HAND SINK
OR EQUIVALENT
19
AVANTCO ICE UC-160-FA 26" UNDER COUNTER
ICE MACHINE OR EQUIVALENT
20
ROYAL INDUSTRIES WT 3624 36" WORK TABLE OR
EQUIVALENT, W/ RAPID BEVERAGE CHILLER
SELECTED & PROVIDED BY OWNER. G.C. TO
COORDINATE WATER SUPPLY LINE FROM
COOLER & ELECTRICAL SUPPLY.
41
1
TYPE 1: NEW INTERIOR WALL PARTITION
- SEE SECTION 1/A-2.0
2
EXISTING INTERIOR WALL PARTITION TO REMAIN
TYPE 2: NEW INTERIOR WALL PARTITION
- SEE SECTION 2/A-2.0
3
TYPE 3: NEW INTERIOR WALL PARTITION
- SEE SECTION 2/A-2.0
GENERAL NOTES:
1.DOORS 6" FROM FACE OF WALL OR CENTERED AS SHOWN, UNLESS NOTED
OTHERWISE.
2.DIMENSIONS ARE TO EXISTING FINISH FACE AND FACE OF NEW STUDS,
UNLESS NOTED OTHERWISE.
3.PATCH & REPAIR EXISTING WALLS & CEILINGS AS REQUIRED
4.NEW FLOOR FINISH THROUGHOUT. PROVIDE TRANSITION STRIP BETWEEN
ROOMS WITH DIFFERENT FLOOR FINISHES. AS APPLICABLE.
5.ALL DOORS TO RECEIVE LEVER-TYPE COMMERCIAL GRADE ACCESSIBLE
HARDWARE ON ALL DOORS. SEE DOOR SCHEDULE.
6.SEE FINISH PLAN & SCHEDULE FOR ALL FINISHES.
7.OWNER TO APPROVE & PROVIDE FINAL SELECTION OF ALL BAR EQUIPMENT.
8.G.C. TO COORDINATE INSTALL AND PROVIDE POWER/WATER SUPPLY FOR
ALL BAR EQUIPMENT.STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
SCALE:1/4"=1'-0" NORTH
NORTH
1 02/08/22 REMOVED DRIVE-THRU WINDOW,
BOLLARD, & CANOPY.
1
1
1
L3
L2
3'-6"2'-8"4'-0"5'-7"5'-7"4'-0"6'-0"3'-0"5'-8"2'-0"L2 5'-8"EQ.EQ.
EQ.EQ.EQ.EQ.
G.W.B.
9'-0"
G.W.B.
9'-0"
L2
L2 L2
L2 L2
L2 L2
L2 L2 L2 L2
L2L2
L2 L2
L1
L1
3'-6"9'-8"4'-8"19'-9"
5'-4"
6'-1"
7'-4"3'-8"3'-6"5'-0"7'-2"5'-0"EQ.EQ.5'-3"5'-3"3'-10"
EQ.EQ.4'-8"4'-8"3'-0"G.W.B.
11'-11"2'-0"3'-2"2'-0"G.W.B.
11'-11"
G.W.B.
11'-11"
C.T.
10'-0"
G.W.B.
11'-11"
G.W.B.
11'-11"
G.W.B.
11'-11"
G.W.B.
9'-0"
G.W.B.
11'-11"
1'-4"
TYP.
1'-8 1/2"5'-0"2'-0"3'-2"2'-0"A-1.2
1
L2 L27'-4"2'-4"5'-4 1/4"
6'-8"6'-8"6'-8"3'-6"1'-10"3'-6"EQ.EQ.4'-11"8'-8"
CEILING LEGEND
G.W.B. CEILING, PATCH & REPAIR EXISTING G.W.B.
AS REQUIRED
NEW 4.5" ROUND DOWNLIGHT 4DR- TL L10 8 80 35 DIM UNV
0 W 07 CS N F1 OR EQUIVALENT.
CEILING EXHAUST GRILL/FAN- SEE ELECT. DWGS.
EXIT SIGN WITH EMERGENCY LIGHTS- BEGHELLI PCH R SA
AT - OR EQUIV. COORDINATE WITH G.C. AND OWNER.
EMERGENCY LIGHTS- BEGHELLIL PEH-1 AT - OR
EQUIV. COORDINATE WITH G.C. AND OWNER
NEW LUMETTA REVEAL CONE 4" PENDANT P1000RV DIMM.
OR EQUIVALENT.
NEW CDS LIGHTING REMUS LED PENDANT DIMM. OR
EQUIVALENT.L1
L2L2
CONTECH LIGHTING CTL 7516-B FAMING PROJECTOR
TRACK FIXTURE LEO RETRO FIT MR16 LAMP CIRCUIT
TRACK FIXTURE ADAPTER TO BE LA1816-B (OR
EQUIVALENT). SELECTED & PROVIDED BY OWNER. G.C.
TO COORDINATE INSTALL & LOCATION.
LED NARROW STRIP LIGHT- WILLIAMS 75R 2 L15
840 DRV UNV OR EQUIVALENT.
NEW VONN LIGHTING DELPHINUS VVC31013 SN 35" LED
LINEAR CHANDELIER DIMM. OR EQUIVALENT.L3
ARMSTRONG METALWORKS BLADES - CLASSICS,
LINEAR PANELS W/ SOUND ABSORPTION.
SELECTED & PROVIDED BY OWNER. G.C. TO
COORDINATE INSTALL OVER SEATING AREA.
PROJECTION SCREEN MOUNTED TO
SUSPENDED CEILING SYSTEM. SELECTED &
PROVIDED BY OWNER. G.C. TO COORDINATE
INSTALL.
INTEGRATED LED COVE LIGHTING. G.C. TO
COORDINATE ALL RUN LENGTHS & INSTALL.
SUSPENDED METAL CEILING TILE SYSTEM,
SELECTED & PROVIDED BY OWNER. G.C. TO
COORDINATE INSTALL.
JUNCTION BOX FOR COOLER LIGHTING, COORDINATE W/
G.C., MANUFACTURER, & INSTALLER.
KEY PLAN
SUITE '2'&'3'
HANGER WIRE
TO STRUCTURE
HANGER WIRE
TO STRUCTURE
COVE LIGHT FIXT.
- SEE RCP. FOR
TYPE
OWNER PROVIDED
GRID SYSTEM
SCALE: 1 1/2" = 1'-0"
1
A-1.2
OWNER PROVIDED
METAL CEILING TILES
RECESSED LIGHT FIXTURE
- CEILING LEGEND
OWNER PROVIDED
RETRACTABLE
PROJECTION SCREEN STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
SCALE: 3/8" = 1'-0"
NORTH
NORTH
1 02/08/22 REVISED FLOOR PLAN
1
SCALE: 3/4" = 1'-0"
1
A-2.0
CONT. RUNNER TRACK SAME GA.
AS STUDS. SECURE TO SLAB W/
3/4" POWER DRIVEN PIN @ 16" O.C.
3 5/8" MTL. STUDS @ 16" O.C. -
FLOOR TO B.O. ROOF DECK
20 GA. MTL. "C" STUDS (TYP. @
ALL PARTITIONS U.N.O.) PROVIDE
HORIZ. BRACING @ 4'-0" O.C. AS
REQUIRED.
5/8" GYP. BD. EACH SIDE W/ 3 1/2"
FIBERGLASS INSULATION BATT
BETWEEN FOR SOUND
ATTENUATION
*PROVIDE MOISTURE RESISTANT
GYP. BD. AT ALL WET WALLS
EXISTING CONC. FLOOR SLABEXISTING CEILING HEIGHTTOP TRACK
BASE - SEE FINISH SCHEDULE
EXISTING G.W.B.
CEILING
SCALE: 3/4" = 1'-0"
2
A-2.0
CONT. RUNNER TRACK SAME GA.
AS STUDS. SECURE TO SLAB W/
3/4" POWER DRIVEN PIN @ 16" O.C.
3 5/8" MTL. STUDS @ 16" O.C. -
FLOOR TO B.O. ROOF DECK
20 GA. MTL. "C" STUDS (TYP. @
ALL PARTITIONS U.N.O.) PROVIDE
HORIZ. BRACING @ 4'-0" O.C. AS
REQUIRED.
5/8" GYP. BD. EACH SIDE W/ 3 1/2"
FIBERGLASS INSULATION BATT
BETWEEN FOR SOUND
ATTENUATION
*PROVIDE MOISTURE RESISTANT
GYP. BD. AT ALL WET WALLS
EXISTING CONC. FLOOR SLABSEE REFLECTED CEILING PLANTOP TRACK
BASE - SEE FINISH SCHEDULECEILING HEIGHT6"3-5/8" METAL
STUDS @ 24" OC.
1/2" CEILING
GRADE GYP. BD.
3-5/8" METAL
STUDS @ 24" OC.
BRACE STUDS BACK TO
STRUCTURE AS REQUIRED
SCALE: 3/4" = 1'-0"
3
A-2.0
CONT. RUNNER TRACK SAME GA.
AS STUDS. SECURE TO SLAB W/
3/4" POWER DRIVEN PIN @ 16" O.C.
3 5/8" MTL. STUDS @ 16" O.C. -
FLOOR TO B.O. ROOF DECK
20 GA. MTL. "C" STUDS (TYP. @
ALL PARTITIONS U.N.O.) PROVIDE
HORIZ. BRACING @ 4'-0" O.C. AS
REQUIRED.
5/8" GYP. BD. EACH SIDE W/ 3 1/2"
FIBERGLASS INSULATION BATT
BETWEEN FOR SOUND
ATTENUATION
*PROVIDE MOISTURE RESISTANT
GYP. BD. AT ALL WET WALLS
EXISTING CONC. FLOOR SLABSEE REFLECTED CEILING PLANTOP TRACK
BASE - SEE FINISH SCHEDULECEILING HEIGHT1/2" CEILING
GRADE GYP. BD.
3-5/8" METAL
STUDS @ 24" OC.
EXISTING
G.W.B. CEILING
SEE REFLECTED CEILING PLANCEILING HEIGHTSTATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
1
1 02/08/22 REMOVED BOLLARD & DRIVE THRU
WINDOW DETAILS
1.PROVIDE EPOXY PAINTED M.R. G.W.B. AT WET WALLS.
2.PROVIDE 3-1/2" SOUND BATTS IN ALL WALLS.
3.ALL FIXTURES AND ACCESSORIES TO BE BARRIER FREE. SEE THIS SHEET FOR
MOUNTING HEIGHTS LEGEND AND TYPICAL FIXTURE & ACCESSORY HEIGHTS.
4.PROVIDE INTERNATIONAL SYMBOL FOR H.C. RESTROOMS - MOUNT ON LATCH SIDE
OF DOOR, 60" A.F.F. TO CENTER OF SIGNAGE. SIGNAGE PER ADA REQUIREMENTS.
5.GENERAL CONTRACTOR TO FURNISH AND INSTALL ALL TOILET ACCESSORIES.
6.BATHTUB TO BE SELECTED BY OWNER.
7.ADDITIONAL FREE-STANDING WASTE RECEPTACLES BY TENANT.
ACCESSORIES ARE MANUFACTURED BY BOBRICK, UNLESS NOTED OTHERWISE
42" GRAB BAR
36" GRAB BAR
MIRROR (18" X 36")
- SURFACE MTD.
TOILET TISSUE DISPENSER
- DBL. ROLL TYPE - WALL SURFACE MTD.
PAPER TOWEL DISPENSER
E
D
C
A
B
B-6806 X 42 (OR EQ.)
B-6806 X 36 (OR EQ.)
B-4288 (OR EQ.)
B-165 1836 (OR EQ.)
B-4262 (OR EQ.)
F
SOAP DISPENSER B-818615 (OR EQ.)
G SANITARY NAPKIN DISPOSAL B-254 (OR EQ.)- SURFACE MTD.
- SURFACE MTD.
SPOUT HEIGHT AND KNEE CLEARANCEWHEELCHAIR TURNING SPACE CLEAR FLOOR SPACE 4'-1 3/4"4'-0"5'-0"5'-0"CLEARMIN.MIN.8"6"
1'-7"
EQUIPMENT PERMITTED IN
SHADED AREA
PROVIDE ACCESSORY APRON TO
BOTTOM OF HIGHER DRINKING
FOUNTAIN TO COMPLY WITH ADA
27" FLOOR TO UNDERSIDE
REQUIREMENT FBAC 307.1'-0 1/2"2'-3"3'-0"2'-3"MAX1'-0 1/2"2'-3"3'-0"MAX1'-7"2'-10" MAX.3'-4"HANDICAPMAX.MIRROR
WATER PIPING
ON H.C. SINK
COVER DRAIN
INSULATE OR
2'-5"2'-10"MIN.MAX.8"
6"9"PROVIDE
BLOCKING AS
REQUIRED
8"C
TOILET PAPER DISPENSER OUTLET MAY
BE LOCATED BETWEEN
15" A.F.F. TO 32" A.F.F. - MUST MAINTAIN
1-1/2" CLEAR BELOW GRAB BAR
1'-3"
C
MIN.NOTE: HEIGHTS SHOWN AS PER 2017 FLORIDA ACCESSIBILITY
REQUIREMENTS MANUAL. A MODIFIED VERSION OF ANSI A117.1 2009 AND
AMERICANS WITH DISABILITIES ACT, 2010 (A.D.A.).1'-6"HANDICAPFLUSH ON SINK
SIDE OF TOILET
2'-0"1'-0"
1'-5"
C
5'-0"
3'-0"
MIN.MIN.
MIN.
1'-0"3'-6"
MAX.MIN.
4'-6"
MIN.
LAVATORY
MIRROR
2'-11"TOP OF BAR1 1/2" GRAB BAR W/ 1 1/2"
CLEARANCE FROM WALL.
IF LONGER THAN 32",
SECURE AT CENTER ALSO.1 1/2"CLEAR1'-0"CLEAR1'-3"4'-0"SOAP DISP.ELECTRIC
HAND DRYER -
IF APPLICABLE
25" TO 30"SANITARY
NAPKIN
DISPOSAL
4'-6"RECOMMENDEDTO TOP5'-2"RECOMMENDEDTO TOP3'-0 1/8"42" to 46"RECESSED
WASTE
RECEPTACLE
RECESSED
SANITARY
NAPKIN
VENDOR
30" TO 48"TOILET SEAT
COVER
DISPENSER
2'-9"TO CHANGINGSURFACE3'-8"FLOOR TO HANDLEAREA2'-4 3/4"2'-4 3/4"BOTTOM CLOSEDBEDBOTTOM OFBEDKB200-SS BABY
CHANGING
STATION
2'-9"REACH RANGEFRONT SIDE
38" TO 40"HEAVY DUTY
CLOTHES HOOK
REACH RANGE -
SHOWN HATCHED
PAPER TOWEL
DISP.5'-2"RECOMMENDEDTO TOPPAPER TOWEL
DISP. / WASTE
RECEPTACLE5'-0"MINIMUM4'-0"MAXIMUMSIGN
BASELINE OF THE
LOWEST TACTILE
CHARACTER
NTS
MIRROR
A
F
B
ED
C 9'-0"PAINTED M.R.
GYPSUM BOARD
SCALE: 3/8" = 1'-0"A-3.0
A
PAINTED M.R.
GYPSUM BOARD
9'-0"C
ED
SCALE: 3/8" = 1'-0"A-3.0
B
PAINTED M.R.
GYPSUM BOARD
9'-0"C
ED
SCALE: 3/8" = 1'-0"A-3.0
C
G
STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
SCALE: 1/2" = 1'-0"
1
A-3.0
5'-11"7'-2 1/4"7'-2 1/4"A
B
C
D
E
F
G
A
B
C
D
E
F
B
A-3.0
A
A-3.0
RESTROOM
MEN'S
111
RESTROOM
WOMEN'S
112
C
A-3.0
A
A-3.0
NORTH
1'-8"1'-8"3/4"1'-8"
2'-1"42"5"
VINYL BASE
3-5/8" 25 GA.
MTL. STUDS
@ 16" O.C.COUNTER HEIGHT3/4"8"5/8" GYP. BD. W/ FRP-1
(2) 2 X 4 TOP PLATE
VINYL BASE
3-5/8" 25 GA.
MTL. STUDS
@ 16" O.C.
RUNNER TRACK SAME
GA.AS STUDS.SECURE
TO SLAB W/ 3/4" POWER
DRIVEN PIN @ 16" O.C.
WILSONART CLOUDS REST Q4049
QUARTZ COUNTERTOP W/ EASED
EDGE ON 3/4" PLYWOOD
PLYWD. WEB FRAME 48" O.C.COUNTER HEIGHT3'-3"34"3/4"42"1'-8"8"STAINED WOOD VENEER
OVER 3/4" PLYWOOD, OWNER
TO SELECT FINAL FINISH
5/8" GYP. BD. W/ FRP-1
(2) 2 X 4 TOP PLATE
VINYL BASE
3-5/8" 25 GA.
MTL. STUDS
@ 16" O.C.
RUNNER TRACK SAME
GA.AS STUDS.SECURE
TO SLAB W/ 3/4" POWER
DRIVEN PIN @ 16" O.C.COUNTER HEIGHT3/4"FIN. FLR.34"BASE - SEE SCHED.
2'-1"
COUNTERTOP
2" GROMMET -
SEE PLAN FOR
LOCATIONS
ADA MTL. BRACKETS
- AS REQ'D (PROVIDE
BLOCKING)4"WILSONART CLOUDS REST
Q4049 QUARTZ COUNTERTOP &
BACKSPLASH OVER 1/2" PLYWD.
STAINED WOOD VENEER
OVER 3/4" PLYWOOD, OWNER
TO SELECT FINAL FINISH
WILSONART CLOUDS REST Q4049
QUARTZ COUNTERTOP W/ EASED
EDGE ON 3/4" PLYWOOD
PLYWD. WEB FRAME 48" O.C.
WILSONART CLOUDS REST Q4049
QUARTZ COUNTERTOP W/ EASED
EDGE ON 3/4" PLYWOOD
PLYWD. WEB FRAME 48" O.C.
FOOT REST - 3-5/8" 25 GA
MTL. STUDS @16" O.C.8"STAINED WOOD VENEER
OVER 3/4" PLYWOOD, OWNER
TO SELECT FINAL FINISH
5/8" GYP. BD. W/ FRP-1
(2) 2 X 4 TOP PLATE
RUNNER TRACK SAME
GA.AS STUDS.SECURE
TO SLAB W/ 3/4" POWER
DRIVEN PIN @ 16" O.C.
FOOT REST - 3-5/8" 25 GA
MTL. STUDS @16" O.C.
1'-8"
3 5/8"STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
SCALE: 3/8" = 1'-0"
1
A-4.0 3'-3"3'-4"1'-4"3'-4"2'-9"23'-8"2'-1"3'-7"2'-0"A-4.0
A
A-4.0
C
A-4.0
B
A-4.0
D
A
A-4.0 SCALE: 3/4" = 1'-0"
B
A-4.0 SCALE: 3/4" = 1'-0"
C
A-4.0 SCALE: 3/4" = 1'-0"
D
A-4.0 SCALE: 3/4" = 1'-0"
NORTH
FINISH NOTES:
OWNER TO VERIFY & APPROVE ALL
FINISHES PRIOR TO ANY ORDER
GENERAL NOTES:
-G.C. TO COORDINATE GROMMET CUT OUTS
ALONG COUNTER TOP FOR POWER AS REQUIRED.
OUTLETS TO BE CONCEALED W/ POP UP ABILITY
AS APPROVED BY OWNER.
-G.C. & OWNER TO APPROVE SHOP DWGS PRIOR
TO FABRICATION.
1
1 02/08/22 REMOVED DRIVE-THRU WINDOW,
BOLLARD, & CANOPY.
SCALE: 3/8" = 1'-0"
PAINTED HOLLOW
METAL FRAME
SEE SCHED.SEE SCHEDULE2"2"2"A
SEE SCHED.SEE SCHEDULEFCG-1 ALUMINUM TRAFFIC
DOOR
B
STAINLESS
STEEL KICK
PLATE BOTH
SIDES - SEE
SPECS BELOW
WINDOW - SEE
SPECS. BELOW
ELIASON DOUBLE
ACTING DOOR - SEE
SPECS. BELOW
SCALE: 3/8" = 1'-0"
A
SEE SCHEDULE
SEE SCHEDULEPAINTED HOLLOW
METAL DOOR
DOOR - SEE
SCHEDULE
SCALE: 1 1/2" = 1'-0"
1
A-6.0
2
A-6.0
3
A-6.0
H.M. FRAME
JAMB
ANCHORS
DOOR - SEE
SCHEDULE
CAULK (TYP.)
(2) 3-5/8"
MTL. STUDS
SCALE: 1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
EXIST. CONC.
SLAB
FINISH
FLOOR
H.M. FRAME
DOOR - SEE
SCHEDULE
CAULK (TYP.)
20 GA. 3-5/8"
MTL. TRACK
DOOR - SEE
SCHEDULE
SCALE: 1 1/2" = 1'-0"
4
A-5.0
5
A-5.0
6
A-5.0
H.M. FRAME
DOOR - SEE
SCHEDULE
CAULK (TYP.)
(2) 3-5/8"
MTL. STUDS
SCALE: 1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
EXIST. CONC.
SLAB
FINISH
FLOOR
H.M. FRAME
DOOR - SEE
SCHEDULE
CAULK (TYP.)
20 GA. 3-5/8"
MTL. TRACK
STATE O F F LO
R
I
D
AREGI
S
RE D A R C H ECTE ITTTHO M A DU
K
E
S EDWIN
AR0013266
PERMIT ISSUE: (12/14/21)
FINISH NOTES:
1. PROVIDE TRANSITION STRIP BETWEEN DIFFERENT FLOOR FINISHES (TYP).
DOOR & HARDWARE NOTES:
1. PROVIDE LEVER-TYPE COMMERCIAL GRADE ACCESSIBLE
HARDWARE ON ALL DOORS. PROVIDE DOOR STOPS AND
SILENCERS FOR ALL DOORS AND FRAMES.
2. USE EQUIVALENT WHEN NECESSARY.
3. VERIFY KEYING REQUIREMENTS WITH TENANT &
LANDLORD.
MANUFACTURERS
LOCKSET'S & CYLINDERS SCHLAGE
CLOSERS DOR-O-MATIC
BUTT HINGES STANLEY
EXIT DEVICES & REMOVABLE MULLIONS MONARCH
STOPS, SILENCERS , PULLS, PROTECTION ROCKWOOD
PLATES & FLUSH BOLTS
THRESHOLDS & WEATHERSTRIPPING PEMKO
MARK ROOM NAME FLOOR BASE
WALLS CEILING
REMARKSNORTHEASTSOUTHWESTMAT.HT.
101 ENTRY S.C.B-1 --P-1 P-1 GWB 11'-11"
102 HOSTESS S.C.B-1 P-2 --P-1 GWB 11'-11"
103 SEATING AREA S.C.B-1 -P-1 P-1 -GWB 11'-11"
104 SALES FLOOR S.C.B-1 P-1 -P-1 P-1 GWB 11'-11"
105 BAR F-1 B-1 P-1 P-1 --GWB/C.T.VARIES
SUSPENDED METAL CEILING TILE GRID SYSTEM. SELECTED & PROVIDED
BY OWNER. G.C. TO COORDINATE INSTALL. EXIST. GWB ABOVE @ 11'-11"
A.F.F.
106 PREP AREA F-1 B-1 P-1 P-1 P-1 P-1 GWB 11'-11"
107 WALK IN COOLER S.C.B-1 P-1 -P-1 P-1 GWB 11'-11"
108 OFFICE S.C.B-1 P-1 P-1 P-1 P-1 GWB 11'-11"
109 CORRIDOR S.C.B-1 P-1 P-1 -P-1 GWB 11'-11"
110 MEN'S RESTROOM S.C.B-1 P-1 P-1 P-1 P-1 GWB 9'-0"
111 WOMEN'S RESTROOM S.C.B-1 P-1 P-1 P-1 P-1 GWB 9'-0"
DR.
NO.
DR.
TYPE
FRM.
TYPE
OPENING SIZE DOOR
THICK.
DR.
MAT.
FRAME
MAT.
DETAILS HDWR
GRP.REMARKSWIDTHHEIGHTHEADJAMBTHRESHOLD
101 EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.
103 EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST. ADD PANIC HARDWARE
106 B A 3'-0"7'-0"1-1/2"ALUM HM 4 5 6 1
108A EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXISTING INSWING DOOR TO BE MODIFIED TO OUTSWING. REUSE
OR REPLACE EXISTING HARDWARE & FRAME AS REQUIRED.
108B A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 2
108C A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 2
109 EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXIST.EXISTING INSWING DOOR TO BE MODIFIED TO OUTSWING. REUSE
OR REPLACE EXISTING HARDWARE & FRAME AS REQUIRED.
110 A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 3
111 A A 3'-0"7'-0"1-3/4"HM HM 1 2 3 3
MARK ITEM MANUFACTURER COLOR / MODEL REMARKS
B-1 VINYL BASE FLEXCO 4" HIGH GROVE - COLOR TO BE SELECTED BY OWNER
P-1 & P-2 PAINT SHERWIN WILLIAMS COLOR TO BE SELECTED BY OWNER
S.C.SEALED CONCRETE INCRETE SUN BUFF - 840 SEE FINISH NOTES BELOW FOR SEALANT
C.T.CEILING TILE SELECTED BY OWNER SELECTED BY OWNER SUSPENDED METAL CEILING TILE SYSTEM, SELECTED & PROVIDED BY OWNER.
G.C. TO COORDINATE INSTALL.
F-1 RUBBER FLOOR FLEXCO RADIAL LOW PROFILE RLT
ALUM.ALUMINUM
AL/GL ALUMINUM / GLASS
H.M.HOLLOW METAL
WD.WOOD
WD/GL WOOD / GLASS
NOTES:
* SEE PAINT SCHEDULE BELOW.
PAINT SCHEDULE
INTERIOR FINISHES
DRYWALL WALLS, COLUMNS AND CEILINGS
PRIMER: B51W08670 - QUICK DRY INTERIOR/EXTERIOR STAIN BLOCKING PRIMER WHITE
2 COATS: COLOR TO BE SELECTED & PROVIDED BY OWNER
DRYWALL WALLS AND CEILINGS IN RESTROOMS
PRIMER: B51W08670 - QUICK DRY INTERIOR/EXTERIOR STAIN BLOCKING PRIMER WHITE
2 COATS: COLOR TO BE SELECTED & PROVIDED BY OWNER
HOLLOW METAL DOORS AND FRAMES
PRIMER: B66W00310 - PRO INDUSTRIAL PRO-CRYL® UNIVERSAL ACRYLIC PRIMER OFF WHITE
2 COATS: COLOR TO BE SELECTED & PROVIDED BY OWNER
P-5 EXPOSED CEILING STRUCTURES
SPOT PRIME: B66W00310 - PRO INDUSTRIAL PRO-CRYL® UNIVERSAL ACRYLIC PRIMER OFF WHITE
FINISH: COLOR TO BE SELECTED & PROVIDED BY OWNER
SEALED CONCRETE
PRIMER: B65C775 - ARMORSEAL 1K WATERBASED URETHANE FLOOR ENAMEL (1 COAT W/ 10% WATER REDUCTION)
FINISH: B65C775 - ARMORSEAL 1K WATERBASED URETHANE FLOOR ENAMEL
SET 1: EACH DOOR TO HAVE
ELIASON EASY SWING® HINGE SYSTEM
SET 2: EACH DOOR TO HAVE
1 OFFICE LOCKSET AL53S JUP X 11-096 X 10-025 US 26D
3 EA. BUTTS F179 US 26D 4 1/2" X 4 1/2" NRP
1 STOP 443 26D
3 SILENCERS 608
1 CLOSER SC61 X 689 X SNB
SET 3: EACH DOOR TO HAVE
1 PRIVACY LOCKSET AL40S JUP X 11-116 X 10-025 US 26D
3 EA. BUTTS F179 US 26D 4 1/2" X 4 1/2" NRP
1 MOP PLATE 4 X 35 U532D
1 STOP 443 26D
3 SILENCERS 608
1 CLOSER SC61 X 689 X SNB