Loading...
1021 ATLANTIC BLVD UNIT 961 SIGN22-0005 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: EQUITY ONE ATLANTIC VILLAGE INC 1600 NE MIAMI GARDENS DR NORTH MIAMI BEACH FL 33179 COMPANY:ADDRESS:CITY:STATE:ZIP: HERITAGE SIGNS P O BOX 236 GREEN COVE SPRINGS FL 32043 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 177602 0040 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1021 ATLANTIC BLVD 961 SIGN WALL TWO WALL SIGNS for SIERRA GRILLE $8233.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 29 $65.00 SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 58 $325.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.85 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.90 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/29/2022 PERMIT NUMBER SIGN22-0005 ISSUED: 3/29/2022 EXPIRES: 9/25/2022 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00 TOTAL: $429.75 2 of 2Issued Date: 3/29/2022 PERMIT NUMBER SIGN22-0005 ISSUED: 3/29/2022 EXPIRES: 9/25/2022 SIGN PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION SIGN22-0005 By Mike Jones at 9:14 am, Mar 11, 2022 REVIEWED FOR CODE COMPLIANCE COPYRIGHT NOTICE THIS DRAWING AND ALL REPRODUCTIONS THEREOF, ARE SOLE PROPERTY OF HERITAGE SIGNS, INC. THIS DRAWING MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT PRIOR WRITTEN CONSENT. Burn rate on plastic as measured by ASTM D-635 is 1.8 inches per minute 1282 Energy Cove Ct. Green Cove Springs,FL 32043 904-529-7446 904-529-1567 fax Allowed Sq. Ft.: 00 Proposed Sq. Ft.: 00 X Landlord Approval/Date: Client Approval/Date: X Notes: Drawn By: T. Beach Salesperson: C. Knight DWG NAME: \\hs-fs-01\prospects$\Sierra Grill 1-17-22 Client: Sierra Grille 1021 Atlantic Blvd Atlantic Beach, FL 32225 Date: 03.01.22 SIG100-00 PERMIT 1 2 SIGN22-0005 By Mike Jones at 9:16 am, Mar 11, 2022 COPYRIGHT NOTICE THIS DRAWING AND ALL REPRODUCTIONS THEREOF, ARE SOLE PROPERTY OF HERITAGE SIGNS, INC. THIS DRAWING MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT PRIOR WRITTEN CONSENT. Burn rate on plastic as measured by ASTM D-635 is 1.8 inches per minute 1282 Energy Cove Ct. Green Cove Springs,FL 32043 904-529-7446 904-529-1567 fax Client: Sierra Grille 1021 Atlantic Blvd Atlantic Beach, FL 32225 Date: 03.01.22 Allowed Sq. Ft.: 00 Proposed Sq. Ft.: 00 X Landlord Approval/Date: Client Approval/Date: X Notes: Drawn By: T. Beach Salesperson: C. Knight Front Elevation and End View - Internally Illuminated Letters 1” = 1'-0"QTY: 1 EXISTING CABINET (W/ OUT PAN)EXISTING CABINET (W/ PAN)0” PAN0” V.O.0” CUT SIZE0” EXISTING CABINET0” PAN0” V.O.0” CUT SIZE0” EXISTING CABINETHAVE LOTS OF DIMENSIONING TO DO?4’-0”5’-0”6’-0”7’-0”8’-0”9’-0”9’-¹⁄”4’-0”5’-0”6’-0”7’-0”8’-0”9’-0”9’-1/2”DIMENSION/MEASUREMENT TOOLS 12345 DWG NAME: 0”0”0” Front Elevation and End View - Internally Illuminated Letters 1/2” = 1'-0" QTY: 1 \\hs-fs-01\prospects$\Sierra Grill 1-17-22 SIG100-00 PERMIT 0”0”0”0” 19’-0” 20’-0” 87”48”4” Internally illuminated channel letters and channel can. 3/16” white acrylic faces with surface applied digitally printed translucent vinyl and black opaque vinyl outline. 4” deep black aluminum returns and 1” black trimcap face retainers. Channel can with surface applied translucent vinyl with copy reversed out. Internally illuminated by white l.e.d. Modules. Letters and cans mounted flush to existing building fascia. Photo Overlay - Internally Illuminated Letters 3/16” = 1'-0" QTY: 1 52’-0” 4’ X 8’ VINYL 4’ X 8’ DIGITAL PRINT 32 SQ. FT. 14 PC 1 1 COPYRIGHT NOTICE THIS DRAWING AND ALL REPRODUCTIONS THEREOF, ARE SOLE PROPERTY OF HERITAGE SIGNS, INC. THIS DRAWING MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT PRIOR WRITTEN CONSENT. Burn rate on plastic as measured by ASTM D-635 is 1.8 inches per minute 1282 Energy Cove Ct. Green Cove Springs,FL 32043 904-529-7446 904-529-1567 fax Allowed Sq. Ft.: 00 Proposed Sq. Ft.: 00 X Landlord Approval/Date: Client Approval/Date: X Notes: Drawn By: T. Beach Salesperson: C. Knight DWG NAME: Front Elevation and End View - Internally Illuminated Letters 1/2” = 1'-0" QTY: 1 \\hs-fs-01\prospects$\Sierra Grill 1-17-22 19’-0” 20’-0” 87”48”4” Internally illuminated channel letters and channel can. 3/16” white acrylic faces with surface applied digitally printed translucent vinyl and black opaque vinyl outline. 4” deep black aluminum returns and 1” black trimcap face retainers. Channel can with surface applied translucent vinyl with copy reversed out. Internally illuminated by white l.e.d. Modules. Letters and cans mounted flush to existing building fascia. Photo Overlay - Internally Illuminated Letters 3/16” = 1'-0" QTY: 1 71’-0” Client: Sierra Grille 1021 Atlantic Blvd Atlantic Beach, FL 32225 Date: 03.01.22 SIG100-00 PERMIT 2 2 COPYRIGHT NOTICE THIS DRAWING AND ALL REPRODUCTIONS THEREOF, ARE SOLE PROPERTY OF HERITAGE SIGNS, INC. THIS DRAWING MAY NOT BE REPRODUCED OR MODIFIED IN ANY WAY WITHOUT PRIOR WRITTEN CONSENT. Burn rate on plastic as measured by ASTM D-635 is 1.8 inches per minute 1282 Energy Cove Ct. Green Cove Springs,FL 32043 904-529-7446 904-529-1567 fax Allowed Sq. Ft.: 00 Proposed Sq. Ft.: 00 X Landlord Approval/Date: Client Approval/Date: X Notes: Drawn By: T. Beach Salesperson: C. Knight DWG NAME: Attachment Location Elevation - Internally Illuminated Letters 3/4” = 1'-0" QTY: 1 \\hs-fs-01\prospects$\Sierra Grill 1-17-22 87”48”Client: Sierra Grille 1021 Atlantic Blvd Atlantic Beach, FL 32225 Date: 03.01.22 SIG100-00 PERMIT 2 1” Jewelite Attached To Return With #6 Hex Head Screw. Internal Illumination By White L.e.d.s 1/4” Dia. Drain Hole. Primary Power To Location By Others. 12v 60watt Remote Power Supply In Fire Proof Metal Container. White Acm Backs. .040” Aluminum Returns. Junction Box. 4” Note: Seal All Wall Penetrations To Prevent Water Intrusion Into Building. = 1/4” X 4” Lag Bolts. Typical All Attachment Points. TYPICAL LETTER / CHANNEL CAN SECTION VIEW NTS Existing 5/8” Plywood Fascia Over Metal Studs. 3/16” White Acrylic. Electronic Disconnect Switch. Electronic Disconnect Switch. WIND DESIGN CRITERIA WIND VELOCITY 140 MPH II C +0 -0 50.2 PSF 1.9 RISK CATEGORY EXPOSURE CATEGORY (MMRF) INTERNAL PRESSURE COEFFICIENT COMPONET & CLADDING PRESSURES FORCE COEFFICIENT 1. CONFORMS TO THE REQUIREMENTS OF THE 7TH EDITION (2020) OF THE FLORIDA BUILDING CODE SECTIONS 1609 AND 3107 AND CHAPTER 30 OF ASCE 7-16. 2. BOLTS: ASTM A307 1/4” DIA. X 4” LAG BOLT ANCHORS FASTENING THRU AWP INTO WOOD FASCIA. General Notes and Specifications Construction: aluminum back and returns with plastic face and trim. White LED illumination. Service and Installation Access: thru faces & raceway Electrical Requirements:120 volt 60 htz One 20 amp dedicated sign circuit required Sign to bear listing mark and be installed in accordance w/ the National Electric Code and County ordinances. FINAL ELECTRICAL TO BE MADE TO EXISTING LIGHTING CIRCUIT. 104 SQ. FT. ALLOWED TOTAL SIGNAGE = 29 SQ. FT. BUILDING: 52’ x 20’ = 1040 SQ. FT. 10% OF 1040 = 104 SIGNAGE: 48” x 87” = 29 SQ. FT. 142 SQ. FT. ALLOWED BUILDING: 71’ x 20’ = 1040 SQ. FT. 10% OF 1420 = 142 2 1 1 By Mike Jones at 9:20 am, Mar 11, 2022