1021 ATLANTIC BLVD UNIT 961 SIGN22-0005 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
EQUITY ONE ATLANTIC
VILLAGE INC 1600 NE MIAMI GARDENS DR NORTH MIAMI
BEACH FL 33179
COMPANY:ADDRESS:CITY:STATE:ZIP:
HERITAGE SIGNS P O BOX 236 GREEN COVE
SPRINGS FL 32043
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
177602 0040 SECTION LAND
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1021 ATLANTIC BLVD 961 SIGN WALL TWO WALL SIGNS for SIERRA
GRILLE $8233.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 29 $65.00
SIGN WITH OR WITHOUT ELECTRIC 455-0000-322-1000 58 $325.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.85
STATE DCA SURCHARGE 455-0000-208-0600 0 $3.90
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 3/29/2022
PERMIT NUMBER
SIGN22-0005
ISSUED: 3/29/2022
EXPIRES: 9/25/2022
SIGN PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ZONING WALL SIGN FEE 001-0000-329-1003 0 $30.00
TOTAL: $429.75
2 of 2Issued Date: 3/29/2022
PERMIT NUMBER
SIGN22-0005
ISSUED: 3/29/2022
EXPIRES: 9/25/2022
SIGN PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
SIGN22-0005
By Mike Jones at 9:14 am, Mar 11, 2022
REVIEWED FOR CODE COMPLIANCE
COPYRIGHT NOTICE
THIS DRAWING AND ALL
REPRODUCTIONS THEREOF,
ARE SOLE PROPERTY OF
HERITAGE SIGNS, INC.
THIS DRAWING MAY NOT BE
REPRODUCED OR MODIFIED
IN ANY WAY WITHOUT
PRIOR WRITTEN CONSENT.
Burn rate on plastic
as measured by
ASTM D-635 is 1.8
inches per minute
1282 Energy Cove Ct.
Green Cove Springs,FL 32043
904-529-7446
904-529-1567 fax
Allowed Sq. Ft.: 00
Proposed Sq. Ft.: 00
X
Landlord Approval/Date:
Client Approval/Date:
X
Notes:
Drawn By: T. Beach
Salesperson: C. Knight
DWG NAME:
\\hs-fs-01\prospects$\Sierra Grill 1-17-22
Client:
Sierra Grille
1021 Atlantic Blvd
Atlantic Beach, FL
32225
Date: 03.01.22
SIG100-00 PERMIT
1
2
SIGN22-0005
By Mike Jones at 9:16 am, Mar 11, 2022
COPYRIGHT NOTICE
THIS DRAWING AND ALL
REPRODUCTIONS THEREOF,
ARE SOLE PROPERTY OF
HERITAGE SIGNS, INC.
THIS DRAWING MAY NOT BE
REPRODUCED OR MODIFIED
IN ANY WAY WITHOUT
PRIOR WRITTEN CONSENT.
Burn rate on plastic
as measured by
ASTM D-635 is 1.8
inches per minute
1282 Energy Cove Ct.
Green Cove Springs,FL 32043
904-529-7446
904-529-1567 fax
Client:
Sierra Grille
1021 Atlantic Blvd
Atlantic Beach, FL
32225
Date: 03.01.22
Allowed Sq. Ft.: 00
Proposed Sq. Ft.: 00
X
Landlord Approval/Date:
Client Approval/Date:
X
Notes:
Drawn By: T. Beach
Salesperson: C. Knight
Front Elevation and End View - Internally Illuminated Letters 1” = 1'-0"QTY: 1 EXISTING CABINET (W/ OUT PAN)EXISTING CABINET (W/ PAN)0” PAN0” V.O.0” CUT SIZE0” EXISTING CABINET0” PAN0” V.O.0” CUT SIZE0” EXISTING CABINETHAVE LOTS OF DIMENSIONING TO DO?4’-0”5’-0”6’-0”7’-0”8’-0”9’-0”9’-¹⁄ ”4’-0”5’-0”6’-0”7’-0”8’-0”9’-0”9’-1/2”DIMENSION/MEASUREMENT TOOLS 12345
DWG NAME:
0”0”0”
Front Elevation and End View - Internally Illuminated Letters 1/2” = 1'-0"
QTY: 1
\\hs-fs-01\prospects$\Sierra Grill 1-17-22
SIG100-00 PERMIT
0”0”0”0”
19’-0”
20’-0”
87”48”4”
Internally illuminated channel letters
and channel can.
3/16” white acrylic faces with surface
applied digitally printed translucent vinyl
and black opaque vinyl outline.
4” deep black aluminum returns and 1”
black trimcap face retainers.
Channel can with surface applied translucent
vinyl with copy reversed out.
Internally illuminated by white l.e.d. Modules.
Letters and cans mounted flush to existing
building fascia.
Photo Overlay - Internally Illuminated Letters 3/16” = 1'-0"
QTY: 1
52’-0”
4’ X 8’
VINYL
4’ X 8’ DIGITAL PRINT
32 SQ. FT.
14 PC
1
1
COPYRIGHT NOTICE
THIS DRAWING AND ALL
REPRODUCTIONS THEREOF,
ARE SOLE PROPERTY OF
HERITAGE SIGNS, INC.
THIS DRAWING MAY NOT BE
REPRODUCED OR MODIFIED
IN ANY WAY WITHOUT
PRIOR WRITTEN CONSENT.
Burn rate on plastic
as measured by
ASTM D-635 is 1.8
inches per minute
1282 Energy Cove Ct.
Green Cove Springs,FL 32043
904-529-7446
904-529-1567 fax
Allowed Sq. Ft.: 00
Proposed Sq. Ft.: 00
X
Landlord Approval/Date:
Client Approval/Date:
X
Notes:
Drawn By: T. Beach
Salesperson: C. Knight
DWG NAME:
Front Elevation and End View - Internally Illuminated Letters 1/2” = 1'-0"
QTY: 1
\\hs-fs-01\prospects$\Sierra Grill 1-17-22
19’-0”
20’-0”
87”48”4”
Internally illuminated channel letters
and channel can.
3/16” white acrylic faces with surface
applied digitally printed translucent vinyl
and black opaque vinyl outline.
4” deep black aluminum returns and 1”
black trimcap face retainers.
Channel can with surface applied translucent
vinyl with copy reversed out.
Internally illuminated by white l.e.d. Modules.
Letters and cans mounted flush to existing
building fascia.
Photo Overlay - Internally Illuminated Letters 3/16” = 1'-0"
QTY: 1
71’-0”
Client:
Sierra Grille
1021 Atlantic Blvd
Atlantic Beach, FL
32225
Date: 03.01.22
SIG100-00 PERMIT
2
2
COPYRIGHT NOTICE
THIS DRAWING AND ALL
REPRODUCTIONS THEREOF,
ARE SOLE PROPERTY OF
HERITAGE SIGNS, INC.
THIS DRAWING MAY NOT BE
REPRODUCED OR MODIFIED
IN ANY WAY WITHOUT
PRIOR WRITTEN CONSENT.
Burn rate on plastic
as measured by
ASTM D-635 is 1.8
inches per minute
1282 Energy Cove Ct.
Green Cove Springs,FL 32043
904-529-7446
904-529-1567 fax
Allowed Sq. Ft.: 00
Proposed Sq. Ft.: 00
X
Landlord Approval/Date:
Client Approval/Date:
X
Notes:
Drawn By: T. Beach
Salesperson: C. Knight
DWG NAME:
Attachment Location Elevation - Internally Illuminated Letters 3/4” = 1'-0"
QTY: 1
\\hs-fs-01\prospects$\Sierra Grill 1-17-22
87”48”Client:
Sierra Grille
1021 Atlantic Blvd
Atlantic Beach, FL
32225
Date: 03.01.22
SIG100-00 PERMIT
2
1” Jewelite Attached To Return
With #6 Hex Head Screw.
Internal Illumination
By White L.e.d.s
1/4” Dia. Drain Hole.
Primary Power To
Location By Others.
12v 60watt Remote
Power Supply In Fire
Proof Metal Container.
White Acm Backs.
.040” Aluminum Returns.
Junction Box.
4”
Note: Seal All Wall
Penetrations To
Prevent Water Intrusion
Into Building.
= 1/4” X 4” Lag Bolts.
Typical All Attachment
Points.
TYPICAL LETTER / CHANNEL CAN
SECTION VIEW
NTS
Existing 5/8” Plywood Fascia
Over Metal Studs.
3/16” White Acrylic.
Electronic Disconnect Switch.
Electronic
Disconnect
Switch.
WIND DESIGN CRITERIA
WIND VELOCITY 140 MPH
II
C
+0 -0
50.2 PSF
1.9
RISK CATEGORY
EXPOSURE CATEGORY (MMRF)
INTERNAL PRESSURE COEFFICIENT
COMPONET & CLADDING PRESSURES
FORCE COEFFICIENT
1. CONFORMS TO THE REQUIREMENTS OF THE
7TH EDITION (2020) OF THE FLORIDA BUILDING CODE
SECTIONS 1609 AND 3107 AND CHAPTER 30 OF ASCE 7-16.
2. BOLTS: ASTM A307 1/4” DIA. X 4” LAG BOLT ANCHORS
FASTENING THRU AWP INTO WOOD FASCIA.
General Notes and Specifications
Construction: aluminum back and returns with plastic
face and trim. White LED illumination.
Service and Installation Access: thru faces & raceway
Electrical Requirements:120 volt 60 htz
One 20 amp dedicated sign circuit required
Sign to bear listing mark and be installed in accordance
w/ the National Electric Code and County ordinances.
FINAL ELECTRICAL TO BE MADE TO EXISTING
LIGHTING CIRCUIT.
104 SQ. FT. ALLOWED
TOTAL SIGNAGE = 29 SQ. FT.
BUILDING:
52’ x 20’ = 1040 SQ. FT.
10% OF 1040 = 104
SIGNAGE:
48” x 87” = 29 SQ. FT.
142 SQ. FT. ALLOWED
BUILDING:
71’ x 20’ = 1040 SQ. FT.
10% OF 1420 = 142
2
1
1
By Mike Jones at 9:20 am, Mar 11, 2022