Loading...
1021 Atlantic Blvd COMM22-0014 Sierra Grille interior build out permit 2 of 2SIERRA GRILLE(A-2)UPS(B)JUICE BAR &CAFE (B)BREWZ CRAFTBEER (A-2)HOP SHING(A-2)H&R BLOCK (B)GREENBERGDENTAL &ORTHODONTICS(B)VACANTVACANTVACANTBARBER(B)DOLLAR TREE(M)NAILS& SPA(B)LA FITNESS(A-3)CONSTRUCTION: FBC SECTION 602.2 - TYPE IIIB, NON-SPRINKLEREDTYPE IIIB - TABLE FBC 601STRUCTURAL FRAMEINCLUDING COLUMNS, GIRDERS, TRUSSESBEARING WALLSEXTERIORINTERIORNONBEARING WALLS AND PARTITIONSEXTERIORNONBEARING WALLS AND PARTITIONSINTERIORFLOOR CONSTRUCTIONINCLUDING SUPPORTING BEAMS AND JOISTSROOF CONSTRUCTIONINCLUDING SUPPORTING BEAMS AND JOISTSBUILDING ELEMENT0TYPE IIIB20000TYPE IIIB - TABLE FBC 602< 5FIRE SEPARATION DISTANCE GROUP A-2> 5< 10> 10< 30> 30(FT)TYPE OF CONSTRUCTIONALLOTHERSIIIBALL1110BASIC ALLOWABLE AREA - 9,500 SQ. FT. NS (ASSEMBLY (A-2) - TABLE 506.2)MAX. HEIGHT - 55'-0"ALLOWABLE HEIGHTS AND BUILDING AREAS: TABLES 504.3 & 506.2 - TYPE IIIB, NON-SPRINKLEREDMAX. STORIES - 2OCCUPANCY CLASSIFICATION OF TENANT SPACE: ASSEMBLY (A-2) FBC 303.3; NFPA 3.3.25, 3.3.196.2 AND CHAPTER 12. OCCUPANCYMINIMUM AS REQUIRED BY FBC TABLE 803.11 (NON-SPRINKLERED):VERTICAL EXITSEXIT ACCESS CORRIDORSROOMS & ENCLOSED SPACESAS REQUIRED BY NFPA 101 TABLE A.10.2.2:OCCUPANCYEXIT ACCESSOTHER SPACESCLASS A INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450CLASS B INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450CLASS C INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450AACA A OR BA, B OR CVERTICAL EXITSOTHER EGRESS COMPONENTS (WIDTH PER PERSON SERVED) :LEVEL = .02" (0.2" x 105 OCCUPANTS = 21" REQUIRED)MINIMUM CLEAR WIDTH OPENING OF EXIT DOORS: 32" (32"/0.2" PER PERSON = 160 PERSONS)MAXIMUM TRAVEL DISTANCE TO EXIT (NON-SPRINKLERED): 200 FT;NFPA 101 - 20 FT (ASSEMBLY A-2)MEANS OF EGRESS:NFPA 101 - 200 FT (ASSEMBLY A-2 - NFPA 12.2.6.1)MAXIMUM DEAD END CORRIDOR LENGTH (NON-SPRINKLERED): 20 FT; (FBC 1020.4)OCCUPANCYVERTICAL EXITSEXIT ACCESS CORRIDORSROOMS & ENCLOSED SPACESINTERIOR FINISHES:AS REQUIRED BY NFPA 101 TABLE A.10.2.2:OCCUPANCYEXIT ACCESSOTHER SPACESCLASS A INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450CLASS B INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450CLASS C INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450ASSEMBLY (A-2)BASSEMBLY (A-2)A A OR BA VERTICAL EXITSMEANS OF EGRESS:TENANT AREA:3,300 SF MAXIMUM TRAVEL DISTANCE, DEAD END LENGTH, EXIT AND MEANS OF EGRESS WIDTH: FBC 1006.2.1 & 1020.1& TABLE 1017.2 & 1020.2; NFPA TABLE A.7.6:A SPRINKLER SYSTEM (FBC 1020.1) - 1 HOURSCORRIDOR FIRE-RESISTANCE RATING: CORRIDOR FIRE RATING WITH GREATER THAN 30 PEOPLE & WITHOUTOF LESS THAN 50 (FBC 1010.1.2.1)DOORS SHALL SWING IN THE DIRECTION OF EGRESS EXCEPT WHEN SERVING AN OCCUPANT LOADCOMMON PATH OF TRAVEL: 75 FT; OCCUPANT LOAD MORE THAN 30 & WITHOUT A SPRINKLER NFPA 101 - 20 FT (ASSEMBLY A-2)SYSTEM (FBC TABLE 1006.2.1);MINIMUM CORRIDOR AISLE WIDTH: 44" (FBC TABLE 1020.2)MINIMUM CORRIDOR AISLE WIDTH: 36" (FBC 1020.2; LESS THAN 30 PEOPLE)CLASS I INTERIOR FLOOR FINISH - CRITICAL RADIANT FLUX, NOT LESS THAN 0.45 W/cm2CLASS II INTERIOR FLOOR FINISH - CRITICAL RADIANT FLUX, NOT MORE THAN 0.22 W/cm2 BUTLESS THAN 0.45 W/cm2TABLE 504.3 NSTABLE 504.4 NSRESTAURANT: ASSEMBLY USES INTENDED FOR FOOD AND/OR DRINK CONSUMPTIONTHE BUILDING IS NOT EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM.OCCUPANT LOAD:OCCUPANCY CALCULATIONSPER NFPA LIFE SAFETY 101MINIMUM OCCUPANT LOAD - NFPA TABLE 7.3.1.2 & 12.1.7:OFFICE: 150 GROSS SF PER PERSONCOMMERCIAL KITCHEN (PREP AREA & BAR): 100 GROSS SF PER PERSON (FFPC) OR 200 GROSS SF PER PERSON (FBC)STORAGE, STOCK, WALK-IN COOLER: 300 GROSS SF PER PERSONQUEUING AREA: 5 NET SF PER PERSONUNCONCENTRATED (TABLES AND CHAIRS) = 15 SQ. FT. PER PERSON FLORIDA BUILDING CODE 7th EDITION (2020)FLORIDA BUILDING CODE - ACCESSIBILITY 7th EDITION (2020) FLORIDA FIRE PREVENTION CODE 7th EDITION (2020) (ENCOMPASSING THE 2018 EDITIONS OF NFPA 1 & NFPA 101)NAI OR III O IITHE PROJECT SCOPE IS CHANGE OF TENANT/RESTAURANT NAME & SEATING LAYOUT FOR SIERRA GRILLE IN AN EXISTING RETAIL BUILDING AT ATLANTIC BEACH, FLORIDA. THE PREVIOUS RESTAURANT WAS JUMPIN' JAX HOUSEOF FOOD. THE NUMBER OF SEATING AND OCCUPANTS REMAINS THE SAME. TOTALSCALCULATIONS78 PEOPLE15SEATING ACTUAL = 78 PEOPLE1 PERSONOFFICE = 150 SQ. FT. PER PERSONNET. = 60 SF / 150 SF= 1 PERSONTOTALS78 PEOPLE1 PERSONTOTAL INDOOR OCCUPANT LOAD: 105 PEOPLEINDOOR SEATING = 15 SQ. FT. PER PERSONNET. = 1347 SF / 15 SF= 90 PEOPLEFFPC/NFPA 101FBC102 PEOPLE4 PERSONS BOOTHS: 4 x 02 = 08 SEATS10 PERSONS TABLES: 10 x 1 = 10 SEATS4 PERSONS TABLES: 4 x 07 = 28 SEATS2 PERSON TABLES: 2 x 09 = 18 SEATSBAR STOOLS: 1 x 14 = 14 SEATS2KITCHEN = 200 SQ. FT. (FBC) 100 SQ. FT. (NFPA) PER PERSONNET. = 700SF / 100 = 7 PEOPLE; 700 SF / 200 = 4 PEOPLE7 PEOPLE34 PEOPLE41 PERSONWALK-IN + STORAGE = 300 SQ. FT. PER PERSONNET. = 241 SF / 300 SF= 1 PERSON1 PERSON18 PEOPLESTANDING SPACE = 7 SQ. FT. PER PERSONNET. = 124 SF / 7 SF= 18 PERSON18 PEOPLE0WATER CLOSETS ASSEMBLY (A-2)1 WC PER 75 MALE/FEMALE 1 LAV PER 200 MALE/FEMALE 51 MALES51 FEMALESTOTAL OCCUPANT LOAD - 102PLUMBING FIXTURE COUNT PER TABLE 403.1 FLORIDA PLUMBING CODELAVATORIES2 REQUIRED WATERCLOSETS (5 EXISTING WATERCLOSETS)2 REQUIRED LAVATORIES (4 EXISTING LAVATORIES)1 REQUIRED SERVICE SINK - 1 SERVICE SINK PROVIDEDDRINKING FOUNTAINS (FLORIDA PLUMBING CODE SECTION 410.0):DRINKING FOUNTAINS SHALL CONFORM TO ASME A112.19.1M, ASME A112.19.2M OR ASME A112.19.9M, AND WATER COOLERS SHALL CONFORM TO ARI 1010. WHERE WATER IS SERVED IN RESTAURANTS, DRINKING FOUNTAINS SHALL NOT BE REQUIRED.LOCKS ON EXIT DOORS SHALL NOTREQUIRE THE USE OF A KEY, A TOOL OR SPECIAL KNOWLEDGE OR EFFORTFOR OPERATION FROM EGRESS SIDEUNLESS THEY MEET THE REQUIREMENTS OF NFPA 101 7.2.1.5.SIGNAGE READING:EXIT DOOR TACTILEEXITSIGNAGE SHALLCOMPLY w/ANSI/CABOA117.1; MOUNT60" AFF TO CENTERLINE OF SIGNNOTE A:ON THE TENANT'S SUITE. LETTERS PROVIDE MIN 6" HIGH LETTERSTHE STREET THEREFORE THE ADDRESS NUMBER MUST BE VISIBLE & LEGIBLE FROM MAY NEED TO BE LARGER THAN THE MINIMUMOF 6" - COORD w/FIRE MARSHALKITCHEN18" STOCK-POT RANGE 32" 2-PANHOT UNIT 32" 2-PANHOT UNIT WORKTABLE15" x 36" 36" WALL SALAMANDER EXISTING 36"CHARBROILERON NEW STAND COLUMNCOLUMNCOLUMNOFFICEDISHWASHSTORAGEUTILITYWALK-INCOOLERWALK-INCOOLEREXISTING CONC. WALKEXISTING CONC. WALK ADJACENT TENANT : UPS (B) EXISTING (1) HR TENANT WALL (per UL U419) CONTRACTOR TO FIELD VERIFY & CONFIRM@ 36" A.F.F.DINNINGWOMENMENHALL@ 34" A.F.F.P.O.S.CO2TANK2 PERSON30" x 30"2 PERSON30" x 30"10 PERSON108" x 42"TRASH BINNEW 48"GRILLON NEW STAND EXISTING16" GASFRYER EXISTING 48" OPEN TOPREFEXISTING 72" OPEN TOPREF EXISTING WORKTOPREFRIGERATOR HANDSINKICE MAKERAND BINBAG-N-BOXELECTRICALPANELSDISHWASHER S/STABLESHELVINGS/STABLE (24x36)SHELVING (24x48)2 COMPPREPSINKS/STABLE (24x36)S/STABLE (24x60)WORKTABLE18" x 36" WORKTOPREFRIGERATOR S/STABLE (24x60)CHIP WARMERON STANDSAFE4 PERSON48" x 30"BOOTHGLASS DOORREACH-IN POSPOS4 PERSON48" x 30"BOOTHS/STABLE(30x48)S/STABLE(30x48)S/STABLE(30x48)3 COMP SINKSALSASTEA BREWERSODAKEGERATOR12344445124 SF200 SF PERPERSON (FBC)18 PEOPLE700 SF200 SF PERPERSON (FBC)4 PEOPLE100 SF PERPERSON (FFPC)7 PEOPLE15 SF PERPERSON90 PEOPLE1347 SF150 SF PERPERSON1 PEOPLE60 SF300 SF PERPERSON1 PEOPLE241 SF2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"TRASH BIN2 PERSON30" x 30" 2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"EXISTING 1 HR FIRE RATED TENANT SEPARATION WALL PER UL DESIGN U419PERSONS (P) DISCHARGING AT EXIT OR EXIT ACCESS,AND EGRESS CLEAR WIDTH (AT DOORS).INDICATES EXIT OR EXIT ACCESS, NUMBER OFSAMPLE EGRESS TRAVEL PATH AND DISTANCEMAXIMUM TRAVEL DISTANCE TO AN EXTINGUISHER = 75 FTMAXIMUM FLOOR AREA PER UNIT OF A = 1,500 SFMAXIMUM FLOOR AREA PER 2A UNIT = 3,000 SFMAXIMUM FLOOR AREA PER EXTINGUISHER = 11,250 SFPERSONS (P) DISCHARGING AT EXIT OR EXIT ACCESS,AND EGRESS CLEAR WIDTH (AT DOORS).INDICATES EXIT OR EXIT ACCESS, NUMBER OFSAMPLE EGRESS TRAVEL PATH AND DISTANCEMAXIMUM TRAVEL DISTANCE TO AN EXTINGUISHER = 75 FTMAXIMUM FLOOR AREA PER UNIT OF A = 1,500 SFMAXIMUM FLOOR AREA PER 2A UNIT = 3,000 SFMAXIMUM FLOOR AREA PER EXTINGUISHER = 11,250 SFCLASS A FIRES (ORDINARY COMBUSTIBLE MATERIALSSUCH AS WOOD, CLOTH, PAPER RUBBER AND MANY PLASTICS)CLASS B FIRES (LIQUIDS, TARS, OILS, GASES)CLASS C FIRES (ELECTRICAL EQUIPMENT)FIRE EXTINGUISHER TYPE "A" (UL RATING 3A-40B:C) 5 LB MULTIPURPOSE DRY CHEMICALEQUAL TO BADGER MODEL #5MB-6H (A KIDDE COMPANY)FIRE EXTINGUISHER TYPE "B" (UL RATING 2-A:K) 6 LITER (1.56 GAL) EXTINGUISHER FOR CLASS K FIRESEQUAL TO KITCHEN ONE MODEL #KS-6000 BY PYRO-CHEMCLASS K FIRES (COOKING MEDIA - VEGETABLE OR ANIMAL OIL AND FATS)FIRE EXTINGUISHERS SHALL BE CERTIFIED BY A LICENSE FIRE PROTECTION COMPANYCHANGE OF TENANT 1021 ATLANTIC BLVD. ATLANTIC BEACH, FL. 3223302-09-22SIERRA GRILLE SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE csommers@dsae.net CRAIG A. SOMMERS, AIA 370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.ARCHITECT - AR0016480 CASCASCODE DATA G-1EXISTING FLOOR PLANARCHITECTURALA-1CODE DATAG-1G-2LIFE SAFETY PLANSCALE: N.T.S.KEY PLANSCALE: N.T.S.STREET MAPPROJECT SITEFLOOR PLANA-2SCALE:1/8"= 1'-0"OCCUPANCY CALCULATION KITCHEN18" STOCK-POTRANGE32" 2-PANHOT UNIT 32" 2-PANHOT UNITWORKTABLE15" x 36"36" WALLSALAMANDER EXISTING 36"CHARBROILERON NEW STANDCOLUMNDININGOFFICEDISHWASHSTORAGE UTILITYWALK-INCOOLERWALK-INCOOLEREXISTING CONC. WALKEXISTING CONC. WALK ADJACENT TENANT : UPS (B) EXISTING ONE HOUR FIRE RATED TENANT SEPARATION WALL (PER UL U419) CONTRACTOR TO FIELD VERIFY & CONFIRM 51'-7"59'-3"@ 36" A.F.F.DINNINGWOMENMENHALL@ 34" A.F.F.P.O.S.CO2TANK2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"2 PERSON30" x 30"2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"10 PERSON108" x 42"TRASH BINTRASH BINNEW 48"GRILLON NEW STANDEXISTING16" GASFRYER EXISTING 48" OPEN TOPREFEXISTING 72" OPEN TOPREFEXISTING WORKTOPREFRIGERATOR HANDSINKICE MAKERAND BINBAG-N-BOXELECTRICALPANELSDISHWASHERS/STABLESHELVINGS/STABLE (24x36)SHELVING (24x48)2 COMPPREPSINKS/STABLE (24x36)S/STABLE (24x60)WORKTABLE18" x 36"WORKTOPREFRIGERATORS/STABLE (24x60)CHIP WARMERON STANDSAFE4 PERSON48" x 30"BOOTHGLASS DOORREACH-INPOSPOS4 PERSON48" x 30"BOOTHS/STABLE(30x48)S/STABLE(30x48)S/STABLE(30x48)3 COMP SINKSALSASTEA BREWERSODAKEGERATOR160P32"NOTE A160P32"NOTE A160P32"NOTE AFE-AFE-AFE-AFE-B2 PERSON30" x 30" 2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"100'17'26'40'40'25'25'5% OF SEATING IS REQUIRED TO ACCESSIBLE5% OF 78 SEATS IS 04 SEATS5% OF SEATING SHALL BE ACCESSIBLE COMPLYING WITH SECTION 902 FBC-ACCESS 226.1)(28" HIGH MIN.; 34" HIGH MAX FBC-ACCESS 902.3)INDOOR SEATING4 PERSONS BOOTHS: 4 x 02 = 08 SEATS10 PERSONS TABLES: 10 x 1 = 10 SEATS4 PERSONS TABLES: 4 x 07 = 28 SEATS2 PERSON TABLES: 2 x 09 = 18 SEATSBAR STOOLS: 1 x 14 = 14 SEATSTOTAL 78 SEATSCHANGE OF TENANT 1021 ATLANTIC BLVD. ATLANTIC BEACH, FL. 3223302-09-22SIERRA GRILLE SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE csommers@dsae.net CRAIG A. SOMMERS, AIA 370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.ARCHITECT - AR0016480 CASCASLIFE SAFETY PLANSCALE:1/4"= 1'-0"FLOOR PLANG-2 COLUMNCOLUMNCOLUMNCOLUMNDINNINGOFFICEDISHWASHKITCHENSTORAGEUTILITYWALK-INCOOLERWALK-INCOOLEREXISTING CONC. WALKEXISTING CONC. WALK ADJACENT TENANT : UPS BUSINESS OCCUPANCY EXISTING (1) HR TENANT WALL (per UL U419) CONTRACTOR TO FIELD VERIFY & CONFIRM 51'-7"59'-3"@ 36" A.F.F.DINNINGWOMENMENHALL@ 34" A.F.F.P.O.S.CO2TANKCHANGE OF TENANT 1021 ATLANTIC BLVD. ATLANTIC BEACH, FL. 3223302-09-22SIERRA GRILLE SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE csommers@dsae.net CRAIG A. SOMMERS, AIA 370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.ARCHITECT - AR0016480 CASCASEXISTING FLOOR PLANSCALE:1/4"= 1'-0"EXISTING FLOOR PLANA-1 KITCHEN18" STOCK-POTRANGE32" 2-PANHOT UNIT 32" 2-PANHOT UNITWORKTABLE15" x 36"36" WALLSALAMANDER EXISTING 36"CHARBROILERON NEW STANDCOLUMNCOLUMNCOLUMNCOLUMNDININGOFFICEDISHWASHSTORAGE UTILITYWALK-INCOOLERWALK-INCOOLEREXISTING CONC. WALKEXISTING CONC. WALK 51'-7"59'-3"@ 36" A.F.F.DINNINGWOMENMENHALL@ 34" A.F.F.P.O.S.CO2TANK2 PERSON30" x 30"2 PERSON30" x 30"10 PERSON108" x 42"TRASH BINNEW 48"GRILLON NEW STANDEXISTING16" GASFRYER EXISTING 48" OPEN TOPREFEXISTING 72" OPEN TOPREFEXISTING WORKTOPREFRIGERATOR HANDSINKICE MAKERAND BINBAG-N-BOXELECTRICALPANELSDISHWASHERS/STABLESHELVINGS/STABLE (24x36)SHELVING (24x48)2 COMPPREPSINKS/STABLE (24x36)S/STABLE (24x60)WORKTABLE18" x 36"WORKTOPREFRIGERATORS/STABLE (24x60)CHIP WARMERON STANDSAFE4 PERSON48" x 30"BOOTHGLASS DOORREACH-INPOSPOS4 PERSON48" x 30"BOOTHKNEEWALLDIVIDERWALLw/OPENINGSKNEE WALL42" HIGH BAR COUNTERS/STABLE(30x48)S/STABLE(30x48)S/STABLE(30x48)3 COMP SINKSALSASTEA BREWERSODAKEGERATOR2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"4 PERSON36" x 36"TRASH BIN2 PERSON30" x 30" 2 PERSON30" x 30"4 PERSON36" x 36"4 PERSON36" x 36"CHANGE OF TENANT 1021 ATLANTIC BLVD. ATLANTIC BEACH, FL. 3223302-09-22SIERRA GRILLE SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE csommers@dsae.net CRAIG A. SOMMERS, AIA 370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.ARCHITECT - AR0016480 CASCASFLOOR PLANSCALE:1/4"= 1'-0"FLOOR PLANA-2