468 Aquatic Dr RES22-0233 2 of 2 exterior door submittal3/4" O.A. INSULATED GLASSGLAZING DETAILINTERIOREXTERIOR0.5" MIN. GLASSBITEAMERICAN CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORS50 SERIES / V1 SERIES /(5500/5700)GLIDING PATIO DOORS(NON-HVHZ)(NON-IMPACT)SHEET:DWG. #:1SWD037 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSCLDWG. BY:DATE:09.26.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS DOCUMENT.50 SERIES / V1 SERIES/(5500/5700) GLIDING PATIO DOORS (NON-HVHZ)(NON-IMPACT)5FL 14998FL #:PREPARED BY:AMERICAN CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVERLINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03546TH FBC EDITION FM 10/177TH FBC EDITION LH 10/20DESIGN PRESSURE TABLESIZE CONFIGURATION DESIGN PRESSURE MISSILE IMPACT RATING96.0" X 82.0" XO +25/-25 PSFNON-IMPACT72.0" X 96.0" XO +20/-20 PSFNON-IMPACT76.0" X 82.0" XO +30/-30 PSFNON-IMPACT72.0" X 80.0" XO +35/-35 PSFNON-IMPACTGENERAL NOTES:1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TOCOMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC),EXCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THEFOLLOWING:·AAMA/WDMA/CSA 101/I.S.2/A440-112. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2XFRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTINGSYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIEDPRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THEENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OFINSTALLATION.3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHOREDTO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGNAND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER ORARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION.4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAYNOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITECONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THEREQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER ORARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITHTHIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONE TIMEPRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR AHJ.5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THISPRODUCT IN AREAS REQUIRING IMPACT RESISTANCE.6. WINDOW FRAME MATERIAL: PVC7. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS.SEE SHEET 1 FOR GLAZING DETAILS.TABLE OF CONTENTSSHEET REVISIONSHEET DESCRIPTION1BGENERAL NOTES & GLAZING DETAILS2BELEVATIONS & ANCHOR LAYOUTS3 BVERTICAL SECTIONS4 BHORIZONTAL SECTIONS5BINSTALLATION NOTES, ANCHOR DETAILS & SCHEDULEGLAZING NOTE:·GLASS THICKNESS AND TYPE SHALLCOMPLY WITH ASTM E-1300 GLASSCHARTS REQUIREMENT GENERAL NOTES & GLAZING DETAILS ANCHOR LAYOUTTHROUGH FRAMEELEVATION6.0" FROMCORNER (TYP.) UNIT MAX.WIDTH 96"D.L.O MAX.WIDTH 43.25"UNITMAX.HEIGHT82.0"D.L.O. MAX.HEIGHT75.0"4B4A"O""X"B34CA3D4E4F4"O""X"18.0" MAX.O.C.18.0" MAX.(TYP.)6.0" (TYP.)ANCHOR LAYOUTTHROUGH FRAMEELEVATION UNIT MAX.WIDTH 72"D.L.O MAX.WIDTH 31.125"UNITMAX.HEIGHT96.0"D.L.O. MAX.HEIGHT89.0"4B4A"O""X"B34CA3D4E4F4"O""X"18.0" MAX.(TYP.)6.0" (TYP.)6.0" FROMCORNER (TYP.)18.0" MAX.O.C.SHEET:DWG. #:2SWD037 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSCLDWG. BY:DATE:09.26.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS DOCUMENT.50 SERIES / V1 SERIES/(5500/5700) GLIDING PATIO DOORS (NON-HVHZ)(NON-IMPACT)5FL 14998FL #:PREPARED BY:AMERICAN CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVERLINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03546TH FBC EDITION FM 10/177TH FBC EDITION LH 10/20 ELEVATIONS & ANCHOR LAYOUTS 3VERTICAL SECTIONSNAP ON FLANGE-FRAME INSTALLATIONA3VERTICAL SECTIONTHROUGH FRAME INSTALLATIONBSEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1EXTERIORINTERIORMAXD.L.O.OPENINGMAXFRAMEHEIGHTEXTERIORINTERIORSEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1MAX.D.L.O.HEIGHTMAX.FRAMEHEIGHTMAXPANELHEIGHTMAXPANELHEIGHTSHEET:DWG. #:3SWD037 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSCLDWG. BY:DATE:09.26.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS DOCUMENT.50 SERIES / V1 SERIES/(5500/5700) GLIDING PATIO DOORS (NON-HVHZ)(NON-IMPACT)5FL 14998FL #:PREPARED BY:AMERICAN CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVERLINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03546TH FBC EDITION FM 10/177TH FBC EDITION LH 10/20 VERTICAL SECTIONS 4HORIZONTAL SECTIONTHROUGH FRAME INSTALLATIONA4HORIZONTAL SECTIONTHROUGH FRAME INSTALLATIONC4HORIZONTAL SECTIONMEETING RAILSBSEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1INTERIOREXTERIORINTERIOREXTERIORMAX. FRAME WIDTHMAX. D.L.O. WIDTHMAX. D.L.O. WIDTH4HORIZONTAL SECTIONSNAP ON FLANGE-FRAME INSTALLATIOND4HORIZONTAL SECTIONSNAP ON FLANGE-FRAME INSTALLATIONF4HORIZONTAL SECTIONMEETING RAILSESEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1SEE GLAZINGDETAIL SHEET 1INTERIOREXTERIORINTERIOREXTERIORMAX. FRAME WIDTHMAX. D.L.O. WIDTHMAX. D.L.O. WIDTHMAX. PANEL WIDTHMAX. PANEL WIDTHSHEET:DWG. #:4SWD037 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSCLDWG. BY:DATE:09.26.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS DOCUMENT.50 SERIES / V1 SERIES/(5500/5700) GLIDING PATIO DOORS (NON-HVHZ)(NON-IMPACT)5FL 14998FL #:PREPARED BY:AMERICAN CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVERLINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03546TH FBC EDITION FM 10/177TH FBC EDITION LH 10/20 HORIZONTAL SECTIONS 1/4" MAX.SHIM SPACEMIN. EDGE DISTANCEMIN. EMB.SUBSTRATE BY OTHERSINTERIOREXTERIORINSTALLATION NOTES:1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN.2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TOBE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED.3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF ±1/2 INCH THE DEPICTEDLOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OFTOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THENEXT.4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUMALLOWABLE SHIM STACK TO BE 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATEROCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.5. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOTLIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING.6. FOR MASONRY OR CONCRETE OPENINGS, A 1X WOOD BUCK MAY BE USED (OPTIONAL) AS LONG ASTHE MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THECORRESPONDING HOST SUBSTRATE. SEE GENERAL NOTE #3 ON SHEET 1 FOR MORE INFORMATION.7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANTMATERIAL OR HAVE A CORROSION RESISTANT COATING.8. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTOMORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTARJOINT INTO FACE SHELL OF BLOCK.9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'SINSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITHSTRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER.ANCHOR SCHEDULEMETHODSUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENTMIN. EDGEDISTANCETHROUGH FRAMEWOOD: MIN. SG = 0.55 #10 WOOD SCREW1.5"0.75"METAL: 18 GAUGESteel, MIN. Fy = 33KSI#14 TEK SCREW3 THREADS MINPENETRATION BEYONDMETAL0.75"CONCRETE:f'c=3000PSI1/4" ITW TAPCON1.75"2.5"MASONRY: CMU perASTM C90 MIN. 2000PSI1/4" ITW TAPCON1.75"2.5"NOTE:JAMB HAVE SIMILAR DETAILSESTCODE5ANCHOR DETAILTHROUGH FRAME (HEAD)A1/4" MAX.SHIM SPACEMIN. EDGE DISTANCEMIN. EMB.SUBSTRATE BY OTHERSINTERIOREXTERIORESTCODE5SNAP ON FLANGEANCHOR DETAILTHROUGH FRAME (HEAD)BSHEET:DWG. #:5SWD037 BUILDING DROPS, INC. 398 E. DANIA BEACH BLVD., STE. 338 DANIA BEACH, FL 33004 PH: (954)399-8478 FAX: (954)744.4738 WEB: www.buildingdrops.comOFSCALE:NTSCLDWG. BY:DATE:09.26.17CHK. BY:HFNREMARKSTITLE:BY DATETHE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATEFROM THE REQUIREMENTS DETAILED HEREIN, A LICENSEDENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOCUMENTS FOR USE WITH THIS DOCUMENT.50 SERIES / V1 SERIES/(5500/5700) GLIDING PATIO DOORS (NON-HVHZ)(NON-IMPACT)5FL 14998FL #:PREPARED BY:AMERICAN CRAFTSMAN WINDOWSSILVER LINE WINDOWS AND DOORSONE SILVERLINE DRIVENORTH BRUNSWICK, NJ 08902PH: (888) 741-03546TH FBC EDITION FM 10/177TH FBC EDITION LH 10/20 INSTALLATION NOTES, ANCHOR DETAILS & SCHEDULE