No preview available
 /
     
780 Amberjack Ln ROOF22-0048 metal roof permitOWNER:ADDRESS:CITY:STATE:ZIP: NOTTMEIER ERIC 2055 BEACH AVE ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: MODEL CITY ROOFING dba Roofing Alliance 5151 SUNBEAM RD #12 JACKSONVILLE FL 32257 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171132 0000 ROYAL PALMS UNIT 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 780 AMBERJACK LN ROOF NON SHINGLE METAL ROOF $8050.00 FEES LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 9/20/2022 PERMIT NUMBER ROOF22-0048 ISSUED: 9/20/2022 EXPIRES: 3/19/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BUILDING PERMIT 455-0000-322-1000 0 $95.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $47.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.01 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.68 TOTAL: $274.19 2 of 2Issued Date: 9/20/2022 PERMIT NUMBER ROOF22-0048 ISSUED: 9/20/2022 EXPIRES: 3/19/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION Permit Number: ROOF22-0048 Site Address: 780 AMBERJACK LN City, State Zip Code: Atlantic Beach, Fl 32233 Applied: 8/30/2022 Approved: Issued: Parent Permit: Parent Project: Applicant: <NONE> Owner: NOTTMEIER ERIC Contractor: <NONE> Description: METAL ROOF Finaled: Status: UNDER REVIEW Details: LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: 2ND REVIEW 9/1/2022 9/1/2022 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 3 ATTACHMENTS from jeremy@modelcityroofing.com 9/1/2022 9/2/2022 9/16/2022 BUILDING Building DENIED Notes: 1. The Evaluation Report for the metal roof system is digitally locked and unable to receive plan review stamps. Please resubmit the documents unlocked. 2. To unlock documents; download the report, print it out, re-scan the printed out report and send it in a pdf form with a revision/correction to the Building Department. 3. Resubmittals may generate other review comments. Review Group: AUTO 8/30/2022 8/30/2022 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: ONE ATTACHMENT from jeremy@modelcityroofing.com 8/30/2022 8/31/2022 9/14/2022 BUILDING Building DENIED Notes: 1. All non-shingled roofing systems install go through plan review. 2. Please submit the manufacturer’s installation instructions and the Evaluation Report for the FL# submitted. 3. Resubmittals may generate other review comments. 4. The link to the revision/correction form is : http://coab.us/DocumentCenter/View/10495/Revision-Request-Correction-to-Comments-Route-Sheet- v20181017?bidId= 5. The email address to send resubmittals is : Building-dept@coab.us Printed: Wednesday, 14 September, 2022 1 of 1 Permit Reviews City of Atlantic Beach ROOF22- 0048 ROOF22-0048 ROOF22-0048 PBRInstallation Manual www.TriCountyMetals.com ®available in 1 1/4”36” 12” 1 1/4”36” 12” Transition FlashingPg. 13 Hip Hip Hip Hip Eave Eave EaveEave Eave Eave Eave Eave Valley Valley Valley Valley Ridge Ridge Ridge Gable End Gable End 18’18’ 13’ 4”13’ 4” 19’ 6”19’ 6” 12’28’ 12’ 3” 12’ 3” 49’ 9” 14’ 9”14’ 9” 18’14’14’ 8’ 6”8’ 6” 24’ 7” 24’12’ 3” 14’ 4” 14’ 4” 18’ 14’ 9” 14’ 9” 12’ 3” 26’ 24’ Plumbing Stack 3” Diameter Plumbing Stack 3” Diameter RIDGE RIDGE Panel Fascia Drip Edge Inside ClosuresWoodgrip Screw Trim Nail or Pancake Screw Panel Expanding Foam Panel W Valley Expanding Foam Woodgrip Screw Woodgrip Screw Trim Nail or Pancake Screw Trim Nail or Pancake Screw Step2: To find “C” you will need to mark a string tied to “A” 4’ long and mark another string tied to “ B” that is 5’ long.Place another nail at “C” where the two measurements come together. This will finish the 3-4-5 triangleNOTE: If your line is 3” from the gable at both “A” and ”C” the your house is square. A B C RIDGE EAVEGABLE GABLEStep 1: Temporarily place a nail 3” from the eave and gable as shown here as “A”. Measure 3’ parallel on the eave line and place another nail shown here as “B”. Transition Flashing Woodgrip Screw Panel Panel Inside ClosuresOutside Closures Trim Nail or Pancake Screw Outside Closures Panel Woodgrip Screw Endwall Flashing Trim Nail or Pancake Screw Woodgrip Screw Butyl Panel Side Wall Flashing Panel Gable Flashing Woodgrip Screw Butyl FlexoVent Woodgrip Screw Ridge Cap Outside Closures 3” 6” Color 110o Color 6” 3” 110o Name: _____________________________________________Phone: _________________________________ Address: ________________________________________________________________________________________ Email: _______________________________________________Job Name: __________________________________ Pickup Location: ____________________________________ Delivery Location: _________________________________________________________________________________ Panels Ultra-Rib Gauge: _______________Color: _______________ PBR Gauge: _______________ Color: _______________ TCM-Lok _____________ Gauge: _______________ Color: _______________ SL-Lok Gauge: _______________ Color: _______________ 5V Gauge: _______________Color: _______________ Enter Panel Sizes Quan�ty Feet Inches TRIM QTY Drip Edge Ridge Cap Hip Cap Gable Rake W-Valley Sidewall Endwall Transi�on Flashing Chimney Flashing Panel Starter Z-Flashing Eave Cleat INSULATION/VENTILATION QTY TCM Radiant Barrier TCM Radiant Tape FlexPro Snap Z SEALANTS QTY Peel and Seal TCM Sealant Expanding Foam Butyl Inside Closures Outside Closures UNDERLAYMENTS/PURLINS QTY Ultra HT Wind & Water Synthe�c HT Underlayment 1 x 4 x 12 SYP Quote Request Order Please select: MS-LokGauge: _______________Color: _______________ TrentonOffice # (352) 463-8400Fax # (352) 463-0785 Live OakOffice # (386) 330-0101Fax # (386) 330-0167 OcalaOffice # (352) 622-5500Fax # (352) 622-5502 TallahasseeOffice # (850) 574-4001Fax # (850) 574-4003 Brooksville Office # (352) 587-8120 Fax # (352) 587-8122 DeLandOffice# (386) 738-2579Fax # (386) 734-5044 JacksonvilleOffice # (904) 490-6004 Flat Endwall Flat Ridge Cap Specialty Trim 2(a�ach drawing or draw in box) Notes: FLASHINGS QTY Standard QTY High TempRoof Boots #3: 1/4” - 5” Color: #5: 4 1/4” - 7 1/2” #7: 6”-11” #9: 9” - 19” Electric Pipe Boot Touch-Up Paint Pen Gooseneck Vents Spray Paint Wood Binder QTY FASTENERS Woodgrip Screw QTY WoodZac QTY XG QTY 1” 1 1/2” 2” Pancakes Tek Screws Lap Screws FASTENERS QTY Stainless Rivets Painted Rivets Purlin Screws #9 x 3” Collated Nails S�ck Nails Trim Nails 1-1/4” Felt Nails 1 1/4” S�nger Nails WoodgripFASTENERSWoodgrip Screw QTY WoodZac QTY XG QTY 1” 1 1/2” 2” Pancakes Tek Screws Lap Screws FASTENERS QTY Stainless Rivets Painted Rivets Purlin Screws #9 x 3” Collated Nails S�ck Nails Trim Nails 1-1/4” Felt Nails 1 1/4” S�nger Nails Woodgrip Specialty Trim 1(a�ach drawing or draw in box) Please sketch out your trim and include clear dimension measurements, pitch needed / degrees of each angle needed, and an arrow to help the fabricator know on what side the paint color needs to be oriented. QTY: ___ Ga: ____ Color: ________ Stretched Out: ____QTY: ___ Ga: ____ Color: ________ Stretched Out: ____ Winter Haven Office: (863) 377-2805 #4: 5” - 6.75” FL# 4595.16 R5 Product Evaluation Report TRI COUNTY METALS 29 Ga. Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15/32” Plywood Florida Product Approval # 4595.16 R5 Florida Building Code 2020 Per Rule 61G20-3 Method: 1 –D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Tri County Metals 301 SE 16th Street Trenton, Florida 32693 Engineer Evaluator: Johnathan Green, P.E. #88223 Florida Evaluation ANE ID: 12901 Validator: Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1 – 4 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 02 2020 FL# 4595.16 R5 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2020, Sections 1504.3.2, 1504.7. Product Description: Ultra-Rib Roof Panel, Min. 29 Ga. Steel, 36” Wide, through fastened roof panel over 1x4 wood purlins over 15/32” APA Plywood decking. Non-structural Application. Panel Material/Standards: Material: Min. 29 Ga. Steel conforming to Florida Building Code 2020 Section 1507.4.3. Yield Strength: Min. 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2020, Section 1507.4.3. Panel Dimension(s): Thickness: 0.014” min. Width: 36” maximum coverage Rib Height: ¾” major rib at 9” O.C. Panel Fastener: #9-15 x 1-1/2” HWH Woodgrip with sealing washing or approved equal ¼” minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4. Substrate Description: Min. 1x4 No. 2 SYP wood purlins over min. 15/32” thick, APA Rated plywood over supports at maximum 24” O.C. The 1x4 wood purlins shall be fastened through the plywood into the wood rafters with minimum (2) 8x3” Deck screw at a maximum of 24” O.C. Design of 1x4 wood purlins, plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code 2020. Allowable Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure: 93.5 psf 138.5 psf Fastener Pattern: 9”-9”-9”-9” 6”-3”-6”-3”-6”-3”-6” Fastener Spacing: 24” O.C. 24” O.C. *Design Pressure includes a Safety Factor = 2.0. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 02 2020 FL# 4595.16 R5 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2020, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2020, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ƒ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ƒ UL 1897-2012 - Uplift Test for Roof Covering Systems ƒ FM 4471-92 - Foot Traffic Resistance Test Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 136-0408T-09A, B, Dated 11/18/2009 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 136-0027T-12C, Dated 02/16/2012 3. Certificate of Independence By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC Organization # ANE ID: 12901) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-2012 test standard. 3. The FM 4471-10, Foot Traffic Resistance test standard is equivalent to the FM 4471-92, Foot Traffic Resistance test standard Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer’s recommended details. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 02 2020 FL# 4595.16 R5 Underlayment: Per Florida Building Code 2020, Section 1507.1.1 and manufacturer’s installation guidelines. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2020 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2020 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 02 2020 FL# 4595.16 R5 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 02 2020