763 ATLANTIC BLVD COMM22-0038 FL4613_R10_AE_PER8028 SS REV. 11-14-22_2
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Product Evaluation Report
of
Allegion-Schlage Lock Company, LLC.
Allegion-Schlage SZ/SL/L/CE/L/B/T/H/HE Series
Single Flush Outswing/Inswing Commercial Steel Door
(HVHZ)(Impact)
for
Florida Product Approval
FL# FL4613
Report No. 8028
Current Florida Building Code
Method: 1 – D (Engineering Evaluation)
Category: Exterior Doors
Sub – Category: Swinging Exterior Door Assemblies
Product: Allegion/Schlage SZ/SL/L/CE/L/B/T/H/HE Series
Single Flush Outswing/Inswing Commercial Steel
Door
Door Material: Varies, See Installation Instructions S05-012
Frame Material: Varies, See Installation Instructions S05-012
Product Dimensions: See Installation Instructions, S05-012
Prepared for:
Allegion-Schlage Lock Company, LLC.
11819 N. Pennsylvania Street
Carmel, IN 46032
Prepared by:
Hermes F. Norero
Florida Professional Engineer # 73778
Date: 06/13/2022
Contents:
Evaluation Report Pages 1 – 4
FL#: FL4613
Date: 6/15/2022
Report No: 8028
Page 2 of 4
Manufacturer: Allegion-Schlage Lock Company, LLC.
Product Category: Exterior Doors
Product Sub-Category: Swinging Exterior Door Assemblies
Compliance Method: State Product Approval Method (1)(d)
Product Name: Allegion-Schlage SZ/SL/L/CE/L/B/T/H/HE Series Single Flush Outswing/Inswing
Commercial Steel Door
(HVHZ)(Impact)
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Allegion-Schlage
Lock Company, LLC. based on Method 1d of the State of Florida Product Approval, Department of
Business and Professional Regulation - Florida Building Commission.
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions S05-012, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the “High Velocity Hurricane Zone” (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the Florida Building Code and does not require an impact resistant covering.
4. Site conditions that deviate from the details of Installation Instructions S05-012 require
further engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions S05-012 for size and design pressure limitations.
FL#: FL4613
Date: 6/15/2022
Report No: 8028
Page 3 of 4
Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida
Building Code for manufacturing under a quality assurance program audited by an approved
quality assurance entity through Intertek Testing Services NA, Inc. – QA Entity (FBC
Organization #: QUA1673).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
• ASTM E283-04 (12)
• ASTM E330-14
• ASTM E331-00 (09)
Referenced Data:
1. Product Testing performed by Certified Testing Laboratories
(FBC Organization # TST1577)
Report #: CTLA-2037, Report Date: 06/29/03
Report #: CTLA-3045W, Report Date: 02/16/15
Report #: CTLA-992W, Report Date: 05/28/03
Report #: CTLA-3064W-4, Report Date: 01/08/16
Report #: CTLA-3064W-7, Report Date: 01/08/16
Report #: CTLA-3064W-12, Report Date: 01/08/16
Report #: CTLA-3064W-14, Report Date: 01/08/16
Signed and sealed by Ramesh Patel, FL P.E. No 20224
2. Product Testing performed by Element Materials Technology
(FBC Organization # TST2613)
Report #: ESP011623P, Report Date: 03/09/08
All reports signed and sealed by Jason Sheen, FL P.E. No 67814
3. Product Testing performed by Intertek
(FBC Organization # TST1527)
Report #: G1447.01-450-18, Report Date: 02/07/17
All reports signed and sealed by Joseph Reed, FL P.E. No 67814
4. Quality Assurance
Intertek Testing Services NA, Inc. – QA Entity
(FBC Organization # QUA1673)
FL#: FL4613
Date: 6/15/2022
Report No: 8028
Page 4 of 4
Installation: Refer to Installation Instructions (S05-012) for more details of the installation requirements.
Design Pressure: Refer to Installation Instructions (S05-012) for design pressures dependent on hardware
type, configuration, and size of units.
Equivalence of Test Standards:
Various test standards have been evaluated for differences in test methodology, if any, between tested
editions of the test standards listed below and those editions referenced in the current Florida Building Code.
The manufacturer has tested their products to the following test standard edition(s):
1) ASTM E330-02
Chapter 35 of the current Florida Building Code references the following editions of the above mentioned
test standards:
1) ASTM E330-14
After review of the above mentioned referenced standards and editions, it has been found that the results
and tests carried out meet the requirements for compliance. All referenced standards have been found to be
equivalent.