Loading...
763 ATLANTIC BLVD COMM22-0038 FL4613_R10_AE_PER8028 SS REV. 11-14-22_2 Hermes F. Norero, P.E. Florida P.E. No. 73778 Product Evaluation Report of Allegion-Schlage Lock Company, LLC. Allegion-Schlage SZ/SL/L/CE/L/B/T/H/HE Series Single Flush Outswing/Inswing Commercial Steel Door (HVHZ)(Impact) for Florida Product Approval FL# FL4613 Report No. 8028 Current Florida Building Code Method: 1 – D (Engineering Evaluation) Category: Exterior Doors Sub – Category: Swinging Exterior Door Assemblies Product: Allegion/Schlage SZ/SL/L/CE/L/B/T/H/HE Series Single Flush Outswing/Inswing Commercial Steel Door Door Material: Varies, See Installation Instructions S05-012 Frame Material: Varies, See Installation Instructions S05-012 Product Dimensions: See Installation Instructions, S05-012 Prepared for: Allegion-Schlage Lock Company, LLC. 11819 N. Pennsylvania Street Carmel, IN 46032 Prepared by: Hermes F. Norero Florida Professional Engineer # 73778 Date: 06/13/2022 Contents: Evaluation Report Pages 1 – 4 FL#: FL4613 Date: 6/15/2022 Report No: 8028 Page 2 of 4 Manufacturer: Allegion-Schlage Lock Company, LLC. Product Category: Exterior Doors Product Sub-Category: Swinging Exterior Door Assemblies Compliance Method: State Product Approval Method (1)(d) Product Name: Allegion-Schlage SZ/SL/L/CE/L/B/T/H/HE Series Single Flush Outswing/Inswing Commercial Steel Door (HVHZ)(Impact) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Allegion-Schlage Lock Company, LLC. based on Method 1d of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions S05-012, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the “High Velocity Hurricane Zone” (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of Installation Instructions S05-012 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions S05-012 for size and design pressure limitations. FL#: FL4613 Date: 6/15/2022 Report No: 8028 Page 3 of 4 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through Intertek Testing Services NA, Inc. – QA Entity (FBC Organization #: QUA1673). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E283-04 (12) • ASTM E330-14 • ASTM E331-00 (09) Referenced Data: 1. Product Testing performed by Certified Testing Laboratories (FBC Organization # TST1577) Report #: CTLA-2037, Report Date: 06/29/03 Report #: CTLA-3045W, Report Date: 02/16/15 Report #: CTLA-992W, Report Date: 05/28/03 Report #: CTLA-3064W-4, Report Date: 01/08/16 Report #: CTLA-3064W-7, Report Date: 01/08/16 Report #: CTLA-3064W-12, Report Date: 01/08/16 Report #: CTLA-3064W-14, Report Date: 01/08/16 Signed and sealed by Ramesh Patel, FL P.E. No 20224 2. Product Testing performed by Element Materials Technology (FBC Organization # TST2613) Report #: ESP011623P, Report Date: 03/09/08 All reports signed and sealed by Jason Sheen, FL P.E. No 67814 3. Product Testing performed by Intertek (FBC Organization # TST1527) Report #: G1447.01-450-18, Report Date: 02/07/17 All reports signed and sealed by Joseph Reed, FL P.E. No 67814 4. Quality Assurance Intertek Testing Services NA, Inc. – QA Entity (FBC Organization # QUA1673) FL#: FL4613 Date: 6/15/2022 Report No: 8028 Page 4 of 4 Installation: Refer to Installation Instructions (S05-012) for more details of the installation requirements. Design Pressure: Refer to Installation Instructions (S05-012) for design pressures dependent on hardware type, configuration, and size of units. Equivalence of Test Standards: Various test standards have been evaluated for differences in test methodology, if any, between tested editions of the test standards listed below and those editions referenced in the current Florida Building Code. The manufacturer has tested their products to the following test standard edition(s): 1) ASTM E330-02 Chapter 35 of the current Florida Building Code references the following editions of the above mentioned test standards: 1) ASTM E330-14 After review of the above mentioned referenced standards and editions, it has been found that the results and tests carried out meet the requirements for compliance. All referenced standards have been found to be equivalent.