763 Atlantic Blvd COMM22-0038 DRAWINGS8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 8/22/22 44 4 4 4 44 4 4 4 WAITING RECEPTION CONSULT RETAIL AREA SECURE STORAGE WORK AREA MENS WOMENS JANITOR UTILITY BREAK AREA OFFICE HALLWAY PANEL "A" WAITING A-1,3 A-18 A-5 A-5 A-5 A-7 A-7 A-7 A-38 A-38 A-11 A-11 A-11 A-11 A-17 A-13 +18" A-19 +18" GFI A-13 +18" GFI A-13 +18" GFI A-13 +18" GFI A-23 +18" A-23 +18" A-23 +18" A-23 +48" GFI A-23 +48" A-25+48"A-29+18" A-35 +18" A-31 +48"+48" A-31 +48" +48" A-35 +18" A-35+18" A-35+18" A-35+18" A-37+48" +48" A-37 +48" +48" A-41 +18" A-41+18" A-41 +18" A-41 +18" A-41+18" RTU-1 ON ROOF EF-1 ON ROOFA-24 A-20 A-36A-26,28,30 GFI/WP M/WP +18" GFI GFI C/T CP-1 A-32 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: BRAND DESIGNER: SITE NUMBER: STORE NUMBER: FLUENT 763 ATLANTIC BLVD. ATLANTIC BEACH, FL 32233 06/13/22 ARCVISION: 220224 C A N N A B I S C A R E E1.0 ELECTRICAL POWER PLAN ) E 1/4" = 1'-0"POWER PLAN A NOT 86E' POWER PLAN *ENERAL NOTE6 %POWER PLAN .E<E' NOTE6 A.CONTRACTOR SHALL COORDINATE QUANTITY AND FINAL LOCATION OF ALL TVS WITH OWNER PRIOR TO CONSTRUCTION. B.PROVIDE WORKING CLEARANCE AT ALL ELECTRICAL PANELS PER NEC. C.COORDINATE WITH LOW-VOLTAGE VENDOR FOR EXACT LOCATIONS AND REQUIREMENTS REGARDING ALL POS, SECURITY, IT, AND OTHER LOW VOLTAGE ITEMS. D.REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND HEIGHTS OF ALL FIXTURES. E.OUTLETS FOR WORKSTATIONS AND POS STATIONS SHOULD BE MOUNTED JUST UNDER THE MONITOR SHELVES OR UNDER THE TABLES AND PHONE COUNTER. F.ALL CONDUITS SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS. WHERE CONDUIT CAN'T BE CONCEALED IT MUST BE PAINTED TO MATCH WALL COLORS. G.SEE SYMBOLS LEGEND FOR ADDITIONAL INFORMATION. H.WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT BREAKERS. REPLACE DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS REQUIRED TO MEET THE END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG AND CHARACTERISTICS OF THE EXISTING. THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. I.CONTRACTOR SHALL TRACE OUT ALL EXISTING CIRCUITRY AND DETERMINE IF IS NEEDED. IF CIRCUIT IS NOT NEEDED CONTRACTOR SHALL REMOVE ALL WIRING AND DEVICES TO NEAREST JUNCTION BOX, CAP AND LABEL WIRING AND COVER EXISTING BOX WITH A BLANK PLATE. J.EXISTING CIRCUITRY SHALL BE VERIFIED IN FIELD PRIOR TO START OF WORK. A''ITIONAL NOTE6 1.EC TO VERIFY EXISTING EQUIPMENT TO REMAIN. PROTECT EQUIPMENT DURING CONSTRUCTION. 2.PROVIDE REQUIRED WORKING SPACE/CLEARANCE FOR ELECTRICAL PANEL PER N.E.C.. CONTRACTOR TO CLEARLY IDENTIFY/INDICATE NOT LESS THAN 30"Wx36"D CLEARANCE AREA/ WORKING SPACE (PER IFC 605.3). IF EQUIPMENT IS LARGER THAN 30" WIDE, WORKING SPACE/CLEARANCE SHALL NOT BE LESS THAN EQUIPMENT WIDTH. 3.POS RECEPTACLE AND DATA RAN IN CASEWORK; CONTRACTOR SHALL COORDINATE WITH ARCHITECT AND OWNER FOR EXACT LOCATION, HEIGHT, AND REQUIREMENTS PRIOR TO ROUGH IN. 4.RECEPTACLE AND DATA FOR VIDEO SCREEN. CONTRACTOR SHALL COORDINATE WITH ARCHITECT AND OWNER FOR EXACT LOCATION, HEIGHT, AND REQUIREMENTS PRIOR TO ROUGH IN. 5.JUNCTION BOX FOR TERMINATION TO FLUENT CANNABIS SIGN. FIELD VERIFY THE EXACT MOUNTING LOCATION AND CONNECTION REQUIRED, PRIOR TO ROUGH-IN. PROVIDE SIGN DISCONNECT SWITCH, IF REQUIRED. INSTALL PER N.E.C. ARTICLE 600 SIGNS. 6.NEW LOCATION FOR EXISTING WATER HEATER. CONTRACTOR SHALL EXTEND BRANCH CIRCUIT, CONDUIT, AND ALL ASSOCIATED MATERIALS TO MAKE A SAFE OPERATIONAL SYSTEM AT NEW WATER HEATER LOCATION AND PER N.E.C. REQUIREMENTS. 7.PROVIDE AN UNDER-FLOOR TRENCH BETWEEN LOW-WALL AND BACK OF HOUSE WALL, AS SHOWN. COORDINATE WITH OTHER DISCIPLINES WORK AS NEEDED TO NOT DISTURB OTHERS WORK. CONTRACTOR TO FIELD-VERIFY THE EXACT NUMBER OF CONDUITS REQUIRED FOR P.O.S. POWER/COMMUNICATIONS. INSTALL BELOW-GRADE PER BURIAL REQUIREMENTS IN THE N.E.C. AND SEALED PER THE U.L. LISTING FOR THE ENVIRONMENT ENCOUNTERED. 8.PROVIDE A 3/4" CONDUIT FOR POWER AND A 3/4" CONDUIT FOR COMMUNICATION TO COUNTER. PROVIDE TRANSITION AND STUB-UP INTO COUNTER MILLWORK. EXTEND AND SECURE WIREWAY(S) ALONG THE BACK OF CABINET. MAKE FINAL CONNECTIONS TO OUTLETS AT JUNCTION BOXES. COORDINATE WITH MILLWORK CONTRACTOR FOR "STUB-THRU" LOCATIONS. 9.NEW ROOFTOP UNIT (RTU-1). EC TO PROVIDE 60A, 208V, 3P, NON-FUSED, WEATHERPROOF DISCONNECT SWITCH. SEE PANEL SCHEDULE ON SHEET E3.0 FOR WIRE SIZES. COORDINATE ALL REQUIREMENTS WITH HVAC CONTRACTOR PRIOR TO BID. 10.EC TO PROVIDE GFI WEATHERPROOF DUPLEX RECEPTACLE AT HVAC EQUIPMENT. 11.PROVIDE CONNECTION FROM AIR DUCT SMOKE DETECTORS TO MECHANICAL CONTROL CIRCUIT. COORDINATE ALL REQUIREMENTS WITH HVAC CONTRACTOR PRIOR TO BID. 12.PROVIDE 20A, 120V, WEATHERPROOF TOGGLE SWITCH DISCONNECT FOR EF-1. COORDINATE LOCATION WITH MANUFACTURER. CIRCUIT THROUGH TIMECLOCK FOR OPERATION ONLY DURING OCCUPIED HOURS. 13.PROVIDE A TIMECLOCK FOR CIRCULATING PUMP CONTROL AND TOGGLE SWITCH DISCONNECT. TIMECLOCK SHALL BE WIRED AHEAD OF DISCONNECT. MOUNT ON WALL ADJACENT TO WATER HEATERS. C N TRUE N PROJECT 'NOT 86E' FIRE ALARM: AS REQUIRED, IT SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO ENGAGE THE SERVICES OF AN APPROVED FIRE ALARM CONTRACTOR. THE FIRE ALARM CONTRACTOR SHALL BE REQUIRED TO PROVIDE DRAWINGS, SPECIFICATIONS & INSTALLATION ACCORDING TO MUNICIPALITIES GUIDELINES. FIRE ALARM SERVICE MAY ALSO INCLUDE PROVIDING FIRE ALARM MONITORING TO BUILDING'S INSTALLED FIRE ALARM CONTROL SYSTEM. FIRE ALARM CONTRACTOR TO PROVIDE COMPATIBLE DEVICES & ALL BRACING, WIRING, ETC. COORDINATE WITH LANDLORD'S FIRE ALARM CONTRACTOR FOR DETAILS. EQUIPMENT: THE EQUIPMENT AND DIMENSIONED LOCATIONS FOR CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE, BUT SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, EQUIPMENT ROUGH-IN DRAWINGS, AND/OR THE OWNER. IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN ON THE PLAN. THE ARCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTIFIED, PRIOR TO CONSTRUCTION, OF ANY DEVIATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH-INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH-INS DIRECTLY UPON THE CONTRACTOR. FLORIDA BUILDING CODE REQUIREMENT - ENERGY CONSERVATION: WITHIN 30-DAYS AFTER DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING: 1. A SINGLE-LINE DIAGRAM OF BUILDING ELECTRICAL SYSTEM AND 2. FLOOR PLAN INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. AN OPERATIONS MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OWNER, THE MANUALS SHALL INCLUDE AT MINIMUM, THE FOLLOWING: 3. SUBMITTAL DATA STATING THE EQUIPMENT RATINGS AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. 4. OPERATIONS MANUAL AND MAINTENANCE MANUAL FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. 5. NAMES AND ADDRESS OF AT LEAST ONE QUALIFIED SERVICE AGENCY. PRIOR TO PASSING FINAL INSPECTION, THE REGISTERED DESIGN PROFESSIONAL/INSTALLER SHALL PROVIDE EVIDENCE THAT THE LIGHTING CONTROL SYSTEM HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND MANUFACTURES INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE IN ACCORDANCE WITH SECTIONS C408.3.1.1 & C408.3.1.3 FOR APPLICABLE CONTROL TYPE. 8/22/22 WAITING RECEPTION CONSULT RETAIL AREA SECURE STORAGE WORK AREA MENS WOMENS JANITOR UTILITY WAITING BREAK AREA OFFICE HALLWAY A1 A-12 A1 A-12 A1 A-12 A1 A-12 A1 A-12 A1 A-12 A1 A-12 A1,f A-12 A1,e A-12 A1,f A-12 A1,e A-12 A1,f A-12 A1,e A-12 A1,e A-12 A1,f A-12 A1,e A-12 A1 A-12 A1 A-12 A1,f A-12 A1,e A-12 A1,f A-12 A1,e A-12 A1,d A-8 A1,c A-8 A1,d A-8 A1 A-8 A1 A-8 A1 A-8 A1 A-8 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 A1,d A-8 A1,c A-8 A1,c A-8 A1,d A-8 A1,d A-8 A1,c A-8 A1,c A-8 A1,d A-8 A1,d A-8 A1,c A-8 A1,c A-8 A1,d A-8 A1 A-12 A1/NL A-12 A1 A-12 A1 A-12 A1,a A-6 A1,b A-6 A1,a A-6 A1,b A-6 C1,g A-6 C1,g A-6 C1,g A-6 C1,g A-6 (TYP) (TYP) A1 A-12 A1 A-12 PANEL "A" abcdef A-2 OS OS A1 A-12 OS OS OS A-14 A-14 A-14 A-14 A-14 A-14 A-14 A-14 A-14 A-14 A-14 A-14 A-14 OS A1 A-12 OS EX1 A-8 EX1 A-6 EX1 A-12 A-8EM1 A-8EM1 A-12 EM1 A-12 EM1 A-12 EM1 A1 A-12A-12 EM1 A1 A-12 A-6 EM1 A-6EM1 A-6EM1 A1,a A-6 A-12EM1 A-8EM1 A-12EM1 A-12EM1 A-12 EM1 A-12 EM1 PS CONTRACT DATE: BUILDING TYPE: PLAN VERSION: BRAND DESIGNER: SITE NUMBER: STORE NUMBER: FLUENT 763 ATLANTIC BLVD. ATLANTIC BEACH, FL 32233 06/13/22 ARCVISION: 220224 C A N N A B I S C A R E E2.0 ELECTRICAL LIGHTING PLAN G E 1/4" = 1'-0"LIGHTINGPLAN A 6:ITCH%AN.'ETAIL LIGHTINGPLANGENERALN2TE6 %LIGHTINGPLAN.E<E'N2TE6 A.EMERGENCY LIGHTS/EXIT SIGNS SHALL BE CONNECTED TO UNSWITCHED HOT CONDUCTOR OF CIRCUIT INDICATED. B.REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF ALL FIXTURES. C.REFER TO LIGHTING FIXTURE SCHEDULE. D.SEE SYMBOLS LEGEND FOR ADDITIONAL INFORMATION. E.CONTRACTOR SHALL UTILIZE EXISTING LIGHTING CIRCUITRY FOR RELOCATED LIGHTING FIXTURES. CONTRACTOR SHALL VERIFY CIRCUIT LOAD PRIOR TO START OF WORK AND WORK TO NOT OVERLOAD CIRCUITRY. LIGHTING)I;T8RE6CHE'8LE 1.E.C. TO VERIFY EXISTING CEILING MOUNTED DEVICES (SPEAKERS, REMOTE TEST SWITCH, SMOKE DETECTORS, OCCUPANCY SENSORS, ETC;) FOR REUSE, REMOVE (AS NEEDED), PROTECT AND CLEAN (SAND AND REFINISH AS NEEDED), PROVIDE ADDITIONAL BRACING, AS NEEDED FOR RELOCATION OF DEVICES. EXTEND CIRCUITING, JUNCTION BOX, ETC; TO NEW LOCATIONS (INDICATED ON SHEETS OR PER ON-SITE FLUENT CANNABIS REPRESENTATIVE), NEW DEVICE MOUNTING BASE SHALL BE FLUSH WITH BOTTOM OF CEILING. 2.PROVIDE REQUIRED WORKING SPACE/CLEARANCE FOR ELECTRICAL PANEL PER N.E.C.. CONTRACTOR TO CLEARLY IDENTIFY/INDICATE NOT LESS THAN 30"Wx36"D CLEARANCE AREA/ WORKING SPACE (PER IFC 605.3). IF EQUIPMENT IS LARGER THAN 30" WIDE, WORKING SPACE/CLEARANCE SHALL NOT BE LESS THAN EQUIPMENT WIDTH. 3.DAYLIT ZONE SHOWN FOR REFERENCE PER ENERGY CODE C103.2. 4.NEW RECESSED CAN. SEE LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. CONTRACTOR TO PROVIDE LED FIXTURE WITH WHITE FINISH. VERIFY SPECIFICATION WITH OWNER PRIOR TO INSTALLATION. CONNECT LIGHT FIXTURE TO NEW CIRCUIT INDICATED. 5.NEW LED LINEAR LIGHT. SEE LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. VERIFY SPECIFICATION WITH OWNER PRIOR TO INSTALLATION. PROVIDE JUNCTION BOX FOR CONNECTION FROM FIXTURE TO REMOTE DRIVER. PROVIDE ADDITIONAL STRUCTURAL BRACING, INDEPENDENT FROM DROP CEILING AS NEEDED. 6.CONTRACTOR TO PROVIDE AND INSTALL NEW EMERGENCY EGRESS LIGHTING FIXTURE. SEE LIGHTING SCHEDULE FOR ADDITIONAL INFORMATION. PROVIDE A SEPARATE HOT LEAD FROM LOCAL AREA LIGHTING CIRCUIT TO EM CONTROL IN FIXTURE, BY-PASSING ALL SWITCHING AND LIGHTING CONTROL. CONTRACTOR TO PROVIDE BREAKER IDENTIFICATION OF EMERGENCY SYSTEM(S) ON THAT CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE AND GENERAL NOTES, THIS SHEET. (NOTE: CONTRACTOR TO PROVIDE ADDITIONAL CODE COMPLIANT EMERGENCY EGRESS LIGHTING FIXTURES IF REQUIRED BY THE A.H.J.). 7.NEW FLUSH, CEILING MOUNTED DUAL-TECHNOLOGY OCCUPANCY SENSOR. SET TIMING AND LOADS PER OWNERS RECOMMENDATION. MANUFACTURER: WATTSTOPPER CX-100 OR CI-100. 8.LOCAL LIGHTING CONTROL SWITCH SHALL BE MOUNTED AT 48" AFF. ONLY AS REQUIRED BY ENERGY CODE. 9.PROPOSED MAIN SWITCH BANK LOCATION FOR NEW LIGHTING CONTROL (COORDINATE EXACT SWITCH BANK LOCATION WITH OWNER IN FIELD). CONTRACTOR TO PROVIDE SWITCH INDICATION AND LABEL FOR THEIR INTENDED USE. SEE DETAIL E, THIS SHEET FOR ADDITIONAL INFORMATION. (NOTE: CONTRACTOR TO FIELD VERIFY EACH THE LIGHTING AREA BEING CONTROLLED BY SWITCH LOCATED WITHIN SWITCH BANK, IS WITHIN THE LINE OF SIGHT (VISIBLE) FROM THE CONTROLLING DEVICE LOCATION (SWITCH BANK). ANY SWITCH CONTROLLING LIGHTING IN AREAS, NOT WITHIN THE LINE OF SITE, FROM THE CONTROLLING DEVICE LOCATION (SWITCH BANK), SHALL BE PROVIDED WITH A SWITCH WITH AN ANNUNCIATOR DEVICE (I.E. SWITCH WITH PILOT LIGHT), SO WHEN THE AREA BEING CONTROLLED IS LIT, THE CONTROLLING DEVICE IS ANNUNCIATED. 10.TIMECLOCK AND LIGHTING CONTROLS. SEE DETAIL D, THIS SHEET, FOR ADDITIONAL INFORMATION. PROVIDE A 120-VOLT, 20-AMP DEDICATED BRANCH CIRCUIT FROM A 1-POLE SPACE IN EXISTING PANEL FOR POWER SUPPLY. WALL MOUNT DEVICES (IN CLEAR AREA) IN BREAKROOM OR ADJACENT TO LIGHTING PANEL, NO HIGHER THAN 6'-0" A.F.F.. INTERCEPT ONLY EXISTING RETAIL AREA LIGHTING BRANCH CIRCUIT(S) FROM LIGHTING PANEL AND REROUTE THROUGH NEW LIGHTING CONTROLS. 11.NEW EXTERIOR RECESSED LIGHT. CONTRACTOR SHALL PROVIDE MATCHING MODEL TO DEMOLISHED LIGHT FIXTURE AND REPLACE ANY MATERIALS NEEDED FOR FIXTURE TO WORK PROPERLY AS PER CONSTRUCTION DOCUMENTS. 12.NIGHT LIGHT. PROVIDE A SEPARATE HOT LEAD FROM LOCAL AREA LIGHTING CIRCUIT, BY-PASSING ALL SWITCHING AND LIGHTING CONTROL. 13.AUTOMATIC DAYLIGHTING CONTROL TO BE MOUNTED FLUSH WITH CEILING. COORDINATE EXACT QUANTITIES AND PLACEMENT WITH MANUFACTURERS REQUIREMENTS FOR COMPLETE ZONE COVERAGE. SYMBOL SHOWN FOR REFERENCE ONLY. DO NOT WIRE WITH EMERGENCY LIGHT FIXTURES. PROVIDE CONNECTION TO CONTROL CIRCUIT AFTER TIMECLOCK AND LOCAL SWITCHING. ALL GENERAL LIGHTING WITHIN ZONES (AS SHOWN) SHALL BE CAPABLE OF CONTINUOUS DIMMING AND BE WIRED THROUGH DAYLIGHTING CONTROL SENSORS. CONTROLLER SHALL PERCEIVE INCOMING (OUTDOOR) LIGHTING AND ADJUST GENERAL LIGHTING ILLUMINANCE TO COMPENSATE FOR ADDED DAYLIGHT PER ENERGY CODE REQUIREMENTS. DAYLIGHTING/DIMMING LIGHTING CONTROL PACKAGE SHALL BE INSTALLED PER ENERGY CODE AND PER MANUFACTURER'S SPECIFICATION. COORDINATE WITH FLUENT REPRESENTATIVE FOR FINAL CONTROL DESIGN AND DEVICE APPROVAL. SEE DETAIL F, THIS SHEET FOR ADDITIONAL INFORMATION. 1.CONTRACTOR TO CONSULT WITH LIGHTING MANUFACTURERS TO PROVIDE FIXTURE LAMPS & UL LABELING TO REFLECT ACTUAL LAMP WATTAGE USED, NOT MAX FIXTURE WATTAGE. 2.RECESSED FIXTURES INSTALLED IN AN INSULATED CEILING SHALL BE I.C. RATED. NO.QTY.LOCATION MFR / CATALOG NUMBER DESCRIPTION LAMP BALLAST TYPE#TYPE MOUNTING TYPE HT. VOLT WATT A1 77 ALL HALO H750TML712830TUNVD010 RECESSED LED DOWNLIGHT NA 120 141LEDRECESSED DROP CLG - C1 4 RETAIL AREA ALCON 12160-P-6-40K-RMT 6'-0" LED LINEAR PENDANT NA 120 421LEDPENDANT DROP CLG - C N TRUE N PROJECT *=PROVIDE BY-PASS FOR CIRCUITS REQUIRING 24HR OPERATION.1.PROVIDE LOCAL SWITCHING AS REQUIRED, PER MUNICIPALITY'S ADOPTED VERSION OF THE ENERGY CODE 2.120-VOLT, 30-AMP CONTINUOUS DUTY CONTACTOR (TYPICAL). PROVIDE IN CONFIGURATION, AS SHOWN. 3.SEE DETAIL F, THIS SHEET FOR REQUIRED LIGHTING CONTROL IN THESE AREAS. C LIGHTING RETAIL AREA ** LIGHTING OFFICE/ WORK AREA/ BREAK AREA/ SECURE STORAGEOR H N TC 120 VAC, 2HR (MAXIMUM) TIMER SWITCH (OVERRIDE). SEE PLANS FOR LOCATION. CHANNEL OUTPUT #2 CHANNEL OUTPUT #1 MULTI-CHANNEL ELECTRONIC PROGRAMMABLE TIMECLOCK 120-VAC HVAC EF-1 SPARE ** LIGHTING RECEPTION/ CONSULT/ WAITING * OR C LIGHTING EXTERIOR BUILDING SPARE SIGN INTERIOR BUILDING SPARE 'LIGHTINGC2NTR2L'IAGRA0 NOTES: CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48". RETAIL AREA A c RETAIL AREA B RECEPTION/ WAITING A d RECEPTION/ WAITING B e WORK AREA/ BREAK AREA/ HALLWAY A f WORK AREA/ BREAK AREA/ HALLWAY B ba REMARKS - - EM1 15 ALL E-LITE ELM-809-W 2-HEAD EMERGENCY LIGHT FROG EYE - WHITE EM 120 1025W/ MR16 WALL 6" BELOW CLG. EX1 3 RETAIL AREA, ENTRANCES LITHONIA ECC M6 COMBO EXIT / EMERGENCY LIGHT UNIT. UNIVERSAL MOUNT -120 3--WALL - - LEAD CALCIUM BATTERY (90 MIN) #nSP5 PCD ELV #nPS80 BLK RED WHT H N 120V 20A 1P BLK WHT LIGHTING EMERG. LIGHTING PCAT5 #nCM-ADCX-DZ CEILING MOUNTED, DUAL-ZONE PHOTOCELL WALL-SWITCH AT SWITCHBANK. SEE DETAIL E. PROVIDE UN-SWITCHED HOT TO EMERGENCY LIGHTING BATTERY. PROVIDE SWITCHED HOT TO CONTROL IN DRIVER. FIXTURES WITH ELECTRONIC LOW VOLTAGE DRIVERS IN PRIMARY DAYLIGHTING ZONE.CAT5NOTE: POWER PACK, RELAY PACK, AND PHOTOCELL MANUFACTURED BY ACUITY BRANDS SENSOR SWITCH. COORDINATE ALL REQUIREMENTS WITH MANUFACTURER. PROVIDE UN-SWITCHED HOT TO DEVICE POWER PACKS. (SEE PLAN) PHOTOCELL AND DIMMING RELAYS SHALL BE PROGRAMMED TO PROVIDE THE FOLLOWING FUNCTIONALITY: CONTROLS SHALL PROVIDE CONTINUOUS DIMMING. FOR THE PRIMARY AND SECONDARY ZONES IN EACH SPACE, THE COMBINED ILLUMINANCE FROM THE CONTROLLED LIGHTING AND DAYLIGHT SHALL NOT BE LESS THAN THE ILLUMINANCE FROM CONTROLLED LIGHTING WHEN NO DAYLIGHT IS AVAILABLE. IN THE DARKEST PORTION OF THE DAYLIT ZONE (FURTHEST AWAY FROM WINDOWS OR SKYLIGHTS) THE CONTROL SHOULD NOT OVER-DIM THE LIGHTS; THIS SECTION OF THE DAYLIGHTED AREA SHOULD NOT GET DARKER AS DAYLIGHT LEVELS INCREASE, DUE TO AN INCORRECT CALIBRATION OF THE CONTROLS. IN AREAS SERVED BY LIGHTING THAT IS DAYLIGHT CONTROLLED, WHEN THE ILLUMINANCE RECEIVED FROM THE DAYLIGHT IS GREATER THAN 150 PERCENT OF THE ILLUMINANCE RECEIVED FROM THE GENERAL LIGHTING SYSTEM AT FULL POWER, THE GENERAL LIGHTING POWER IN THAT DAYLIGHT ZONE SHALL BE REDUCED BY A MINIMUM OF 65 PERCENT. E.C. SHALL FIELD MEASURE ACTUAL GENERAL LIGHTING LEVELS AND ADJUST DAYLIGHT SENSOR ACCORDINGLY. )'A<LITC2NTR2L6EN62R'IAGRA0 g P.O.S. PENDANTS 125V, 20-AMP, 1-POLE DIMMER SWITCH (450 MILLIAMP (MAX.) CONTROL) 8/22/22 ELECTRICAL RISER DIAGRAM NOTES: 1.ELECTRICAL DISTRIBUTION EQUIPMENT SHOWN DASHED OR LIGHTWEIGHT IS EXISTING. 2.INFORMATION ON PLANS REGARDING ELECTRICAL DISTRIBUTION EQUIPMENT WAS BASED ON AVAILABLE INFORMATION AT THE TIME OF DESIGN. E.C. SHALL VERIFY EXISTING CONDITIONS. NOTIFY CONSTRUCTION PROJECT MANAGER IMMEDIATELY OF ANY DISCREPANCY AFFECTING THE INTENT OF THE DESIGN CONVEYED HEREIN. EXISTING EXTERIOR WALLINTERIOR GRADEFLOOR SEE PANEL SCHEDULES FOR SIZE AND RATINGS EX. PANEL "A" EXISTING PENETRATION INTO BUILDING EXISTING METER CENTER, VERIFY IN FIELD. EXISTING UTILITY SERVICE ” ” MM M M TO ADJACENT TENANTS CONTRACT DATE: BUILDING TYPE: PLAN VERSION: BRAND DESIGNER: SITE NUMBER: STORE NUMBER: FLUENT 763 ATLANTIC BLVD. ATLANTIC BEACH, FL 32233 06/13/22 ARCVISION: 220224 C A N N A B I S C A R E E3.0 ELECTRICAL ONE-LINE AND PANEL SCHEDULE 8/22/22 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: BRAND DESIGNER: SITE NUMBER: STORE NUMBER: FLUENT 763 ATLANTIC BLVD. ATLANTIC BEACH, FL 32233 06/13/22 ARCVISION: 220224 C A N N A B I S C A R E E4.0 ELECTRICAL SPECIFICATIONS 8/22/22 8/22/22 8/22/22