363 ATLANTIC BLVD COMM22-0033 Treata Tea Shoppe Architectural DWGS REV. 11-2-22_1A0.01 ALL ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL CODES AND ORDINANCES, WHETHER LISTED HEREIN OR NOT. A0.02 ANY & ALL GOVERNING LOCAL LABOR LAWS, REGULATIONS & REQUIREMENTS AND THOSE SET AS BUILDING REQUIREMENTS SHALL BE OBSERVED & FOLLOWED AS THEY RELATE TO THIS PROJECT. A0.03 CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS AND CERTIFICATE OF OCCUPANCY PERMIT AS WELL AS SEPARATE MECHANICAL, ELECTRICAL, AND PLUMBING PERMITS PRIOR TO AND DURING CONSTRUCTION. A0.04 MATERIALS, DIMENSIONS, AND OTHER CONDITIONS NOT OTHERWISE INDICATED IN THESE DRAWINGS SHALL BE ASSUMED AS HAVING THE SAME MEANING AS THOSE MOST SIMILARLY DETAILED AND MORE FULLY DEFINED ELSEWHERE IN THE DRAWINGS. CONTRACTOR TO VERIFY W/ ARCHITECT IN WRITING. A0.05 THE EXTENT OF WORK SHALL BE LIMITED TO THAT INDICATED IN THE CONTRACT DOCUMENTS. NO ADDITIONAL WORK SHALL BE DONE WITHOUT WRITTEN APPROVAL OF OWNER. ANY ADDITIONAL WORK PERFORMED WITHOUT PRIOR WRITTEN APPROVAL BY OWNER SHALL BE AT THE CONTRACTOR'S EXPENSE. A0.06 THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD MEASURING OF EXISTING CONDITIONS PRIOR TO START OF WORK & DURING CONSTRUCTION AS NECESSARY TO ASSURE CONSTRUCTION ADHERENCE TO DRAWINGS. BY ENTERING INTO A CONSTRUCTION CONTRACT FOR THIS WORK, GC SHALL INDICATE HIS FAMILIARITY WITH THE SITE/FIELD CONDITIONS. A0.07 FLOOR TOLERANCE: IN LAYING OUT THE WORK TO BE COMPLETED, CONSIDERATION SHALL BE GIVEN TO VARIATIONS IN THE FLOOR LEVEL RESULTING FROM THE CONSTRUCTION QUALITY AND LIVE AND DEAD LOADS IMPOSED ON THE STRUCTURE. FIELD VERIFICATIONS SHALL BE MADE OF CONDITIONS TO VERIFY CONSTRUCTION TOLERANCES AND ALIGNMENT OF DOOR HEADS. OTHER HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANE. LEVEL FLOORS AS REQUIRED BY USING AN APPROVED LEVELING COMPOUND. A0.08 THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE PRECAUTIONS TO PROTECT BUILDING OCCUPANTS, MATERIALS, & EXISTING FINISHES THROUGHOUT ALL PHASES OF CONSTRUCTION. NOISE, SECURITY, AND DUST BARRIERS BETWEEN CONSTRUCTION AREAS AND OCCUPIED AND PUBLIC AREAS SHALL BE MAINTAINED BY CONTRACTOR. A0.09 THE GC SHALL BE RESPONSIBLE FOR MAINTAINING BUILDING CORRIDORS CLEAR OF PROJECT MATERIALS AND EQUIPMENT. A0.10 GC SHALL PROVIDE GENERAL CARPENTRY AS REQUIRED FOR WORK WHICH MAY NOT FALL UNDER THE JURISDICTION OF A SPECIFIED TRADE BUT IS REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION. A0.11 NO MODIFICATIONS/REVISIONS/CHANGES SHALL BE UNDERTAKEN UNLESS SPECIFICALLY SO INSTRUCTED & APPROVED BY CLIENT. A0.12 CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION. A0.13 THE INTENT OF THE CONTRACT DOCUMENTS IS TO EXCLUDE ALL MATERIALS WHICH CONTAIN KNOWN HAZARDOUS SUBSTANCES. THESE INCLUDE MATERIALS CONTAINING ASBESTOS, POLYCHLORINATED BIPHENYL(PCB), OR ANY OTHER KNOWN SUBSTANCES DETERMINED TO BE A HEALTH HAZARD BY THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) AND OTHER RECOGNIZED AGENCIES. IN STUDYING THE CONTRACT DOCUMENTS, AND AT ANY TIME DURING EXECUTION OF THE WORK, THE CONTRACTOR SHALL AT ONCE REPORT TO THE ARCHITECT ANY MATERIALS CONTAINING HAZARDOUS SUBSTANCES THAT HE/SHE MAY DISCOVER. DO NOT PROCEED WITH INSTALLATION OF HAZARDOUS MATERIALS. A0.14 CONTRACTOR SHALL VERIFY PRESENCE OF HAZARDOUS MATERIALS WITH OWNER. ARCHITECT AND ITS CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL, OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO, ASBESTOS, POLYCHLORINATED BIPHENYL(PCB) OR OTHER TOXIC SUBSTANCES. A0.15 WHERE PRODUCTS ARE SPECIFIED BY REFERENCE STANDARD OR IN DESCRIPTIVE MANNER WITHOUT MANUFACTURER'S NAME, MODEL NUMBER OR TRADE NAME, CONTRACTOR SHALL SELECT MATERIALS MEETING SPECIFIED REQUIREMENTS WHICH DO NOT CONTAIN KNOWN HAZARDOUS SUBSTANCES IN ANY FORM AND SUBMIT TO ARCHITECT FOR APPROVAL. A0.16 INSTALL ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT THAT THE SPECIFICATIONS HEREIN, WHERE MORE STRINGENT, SHALL BE COMPLIED WITH.A0.17 IN MAKING REQUESTS FOR SUBSTITUTION, CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THAT MATERIALS REQUESTED FOR SUBSTITUTION ARE FREE OF KNOWN HAZARDOUS SUBSTANCES IN ANY FORM. A0.18 WARRANTY SHALL BE EXTENDED FOR ALL CONSTRUCTION COMPONENTS, EQUIPMENT AND INSTALLATIONS INCLUDED IN THIS CONTRACT FOR A MINIMUM OF 1 YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. A0.19 GC SHALL RE-EXECUTE ANY WORK THAT FAILS TO CONFORM TO THE DRAWINGS/DETAILS AS SHOWN AND ANY DEFECTS DUE T0 FAULTY MATERIALS OR WORKMANSHIP WHICH APPEAR WITHIN A PERIOD OF ONE (1) YEAR. A0.20 SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT FOR REVIEW. APPROVAL OF SHOP DRAWINGS SHALL NOT RELEASE CONTRACTOR FROM RESPONSIBILITY FOR THE WORK AS SPECIFIED. A0.21 THESE DOCUMENTS INDICATE MATERIALS AND METHODS OF CONSTRUCTION TO ESTABLISH STANDARDS OF QUALITY AND/ OR PERFORMANCE. OTHER MATERIALS AND/OR METHODS WILL BE CONSIDERED BY THE ARCHITECT FOR ACCEPTANCE PROVIDED THAT THEY DO NOT AFFECT THE VISIBLE APPEARANCE. MATERIAL SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TO ORDERING AND/OR FABRICATION. A0.22 ALL REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND WILL BE CONSIDERED ONLY IF BETTER SERVICE FACILITIES, A MORE ADVANTAGEOUS DELIVERY DATE, OR LOWER PRICE WITH CREDIT TO THE OWNER IS PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE ARCHITECT BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY T0 THE PRODUCT SPECIFIED. A0.23 CONTRACTOR SHALL SUBMIT TO THE ARCHITECT, IMMEDIATELY FOLLOWING DIRECTIVE TO PROCEED WITH WORK, CONFIRMATION WITH DELIVERY DATES FOR ORDERS OF MATERIALS AND EQUIPMENT AND ANY LONG LEAD TIME ITEMS. A0.24 DAMAGE: CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIRS OF ANY ACCIDENTAL DAMAGE HE INFLICTS UPON THE EXISTING WORK WHICH WILL REMAIN. IF FOR ANY REASON DAMAGE TO EXISTING WORK OR UTILITIES IS CONSIDERED TO BE UNAVOIDABLE, SUBMIT WRITTEN NOTIFICATION OF THIS BEFORE SIGNING THE CONTRACT. IN THE ABSENCE OF SUCH NOTIFICATION, CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR DAMAGE AND THE COSTS OF SATISFACTORILY REPAIRING OR REPLACING DAMAGED WORK. A0.25 FINAL CLEANING AT COMPLETION SHALL INCLUDE DUSTING OF ALL FINISHED SURFACES, VACUUMING, REMOVAL OF SPOTS, STAINS, LABELS, FINGERPRINTS, SPILLS, AND CLEANING OF ALL INTERIOR GLASS. JOB SITE CLEAN-UP SHALL CONTINUE BEYOND DATE OF SUBSTANTIAL COMPLETION TO MOVE-IN DAY AND SHALL INCLUDE REMOVAL OF ACCUMULATED DEBRIS RESULTING FROM WORK BY TELECOMMUNICATIONS CONTRACTORS AND OTHER VENDORS UNDER CONTRACT TO THE OWNER. (NOTE:FURNITURE PACKING MATERIALS WILL BE RESPONSIBILITY OF FURNITURE VENDOR.) A0.26 FIRE RATED PARTITIONS SHALL BE NOTED IN STENCIL ABOVE FINISHED CEILING PER APPLICABLE CODE. A0.27 VERIFY SPECIFIC SECURITY REQUIREMENTS WITH TENANT. A0.28 SPRINKLER HEAD LOCATION SHALL BE COORDINATED WITH OTHER TRADES BY CONTRACTOR AND SHALL BE AS SPECIFIED BY ENGINEER OR AS REQUIRED BY CODE. SPRINKLERS SHALL BE CENTERED WITHIN EACH CEILING TILE TO PROVIDE A UNIFIED, CONSISTENT AND AESTHETIC ARRANGEMENT. HEADS SHALL BE WHITE FLUSH TYPE OR BUILDING STANDARD IF EQUAL OR BETTER. DRAWING SYMBOLS LEGEND 101 COLUMN GRID A101 1 Ref 1Ref 1 Ref 1Ref INTERIOR ELEVATION DRAWING NUMBER REFERENCE INTERIOR ELEVATION SHEET REFERENCE 1 View Name 1/8" = 1'-0" DRAWING TITLE / NAME / DESCRIPTION DRAWING SCALE A101 1 Ref 1Ref 1 Ref1 Ref BUILDING ELEVATION DRAWING NUMBER REFERENCE BUILDING ELEVATION SHEET REFERENCE 1 A101 SIM BUILDING SECTION DRAWING NUMBER REFERENCE BUILDING SECTION SHEET REFERENCE A1011 SIM DRAWING NUMBER REFERENCE DRAWING SHEET REFERENCE ELEVATION TARGET ROOM NAME DOOR NUMBER WINDOW TYPE / NUMBER WALL TYPE ROOM NUMBER CEILING TYPE FIRE EXTINGUISHER REVISION NUMBER REVISION COMMENT EGRESS DOOR TAG PATH OF TRAVEL NORTH SYMBOL DEMOLITION NOTES NEW ADDITION NOTES 0 Room name 101 1 Add comments or notes here 1t 1i 1t 1i NameElevation 1i Length EXIT SIGN 101(Occupancy Load Served Per Door Egress Width)Doors Clear Width SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 COVER SHEET JAX22070 JULY 25 2022 G001 NUMBER NAME DATE REV. 00 - GENERAL G001 COVER SHEET Sept 29 2022 1 G101 LIFE SAFETY CODE SUMMARY July 25 2022 0 G102 LIFE SAFETY FLOOR PLAN Sept 29 2022 1 G103 ASSEMBLY DETAILS Sept 29 2022 1 4 00.1 - DEMOLITION D110 1RST FLOOR DEMOLITION PLAN Sept 29 2022 1 1 04 - ARCHITECTURAL A110 OVERALL 1ST FLOOR PLAN & RCP Sept 29 2022 1 A401 ENLARGED PLANS Sept 29 2022 1 A601 SCHEDULES Sept 29 2022 1 3 07 - PLUMBING P001 PLUMBING COVER SHEET July 25 2022 0 P002 PLUMBING SPECIFICATIONS July 25 2022 0 P003 PLUMBING SPECIFICATIONS July 25 2022 0 P101 PLUMBING PLAN July 25 2022 0 P102 PLUMBING SCHEDULES July 25 2022 0 P103 PLUMBING ISOMETRIC July 25 2022 0 6 08 - MECHANICAL M001 MECHANICAL COVER PAGE July 25 2022 0 M002 MECHANICAL SPECIFICATIONS July 25 2022 0 M003 MECHANICAL SPECIFICATIONS July 25 2022 0 M004 MECHANICAL SPECIFICATIONS July 25 2022 0 M101 MECHANICAL 1ST FLOOR PLAN Sept 29 2022 1 M501 MECHANICAL DETAILS July 25 2022 0 M601 MECHANICAL SCHEDULES Sept 29 2022 1 7 09 - ELECTRICAL E100 SPECS, LEGEND AND NOTES July 25 2022 0 E200 ELECTRICAL FLOOR PLAN July 25 2022 0 E300 DETAILS & SCHEDULES July 25 2022 0 3 TREATA TEA SHOPPE INTERIOR BUILD OUT JULY 25 2022 363 ATLANTIC BLVD UNIT 9 ATLANTIC BEACH, FL, 32233 DESIGNER FIRM NAME LICENSE PHONE NO EMAIL ARCHITECT ALL CONSTRUCTION &DEVELOPERS NF GABRIEL ARANGO AR 93416 (904) 553-2451 projectmanager@allcnd.com PLUMBING CI-MECH ENGINEERINGINC IAN VEGA PE 83516 (904) 686-8882 ian.vega@ci-mech.com MECHANICAL CI-MECH ENGINEERINGINC IAN VEGA PE 83516 (904) 686-8882 ian.vega@ci-mech.com ELECTRICAL POWER INTEGRATIONLLC SUKUMARAN TBASKARAN PE 70825 (904) 307-9077 sukutb@comcast.net CONTRACTOR/ SHOPDRAWINGS ALL CONSTRUCTION &DEVELOPERS NF GUSTAVO OSPINA CGC 1507345 (904) 449-7902 projectmanager@allcnd.com N SERENE ADVANCED SKIN CARE TREATA TEA SHOPPE 14 THE CANDLE GARDEN STORE 13 12 11 10 9 8 7 6 5 4 3 2 1 363 ATLANTIC BLD UNIT 9, JACKSONVILLE, FL, 32233 363 ATLANTIC BLVD UNIT 9, JACKSONVILLE, FL, 32233 14 13 12 11 10 9 8 KEY PLAN No Date Description 0 July 252022 Permit Issue 1 Sept 292022 Revision 1 1 1 FORWARD4' - 0" MAXFORWARD4' - 0" MAXMIN4' - 0"MIN 2' - 6"MIN2' - 6"4' - 0" 13 1/2" MIN.MAX1' - 5"MIN1' - 2"MIN4' - 0"MIN 2' - 6"MIN.1' - 3"MAX 1' - 0" MIN 3' - 6" MAX 1' - 0" MIN 3' - 6"MAX.1' - 7"MIN 1' - 0"MIN1' - 3"2' - 9"MIN 3' - 0"39.5" W/ SHELF3' - 4"6' - 2"MAX4' - 6"56" MAX - SIDE REACHFORWARD REACH48" MAX.4' - 0"4' - 0" 2' - 6"2' - 6"5' - 0"FORWARD REACH4' - 0" MAXMAX3' - 4"MAX2' - 10"MIN0' - 9"0' - 8" MIN MIN2' - 3"MIN0' - 9"0' - 6" MAX 0' - 8" MINMIN2' - 3"MAX3' - 0"FEMININE NAPKINVENDER HC WALL HUNGSCREEN WALL HUNGURINAL GRAB BAR TOILET PAPERHOLDER MIRROR 18"36"MIRRORW/SHELF 18"36"TOP OF CABINET HANDLE CABINET WHERESHOWN ON PLANS MOUNT ONLATCH SIDEOF DOOR RIM MIRROR (39.5" TOBOT. OF FRAME) MIRROR HOT WATER AND DRAIN LINE TO BE INSULATED WHERE EXPOSED KNEE CLEARANCE KNEE SPACE ELEVATION -FEMININENAPKIN VENDING PROFILE -FEMININENAPKIN VENDING COIN INSERTS PLAN -FEMININENAPKIN VENDER ELEVATION URINAL-WALL HUNG PLAN -URINAL ELEVATION -TOILET WALL MOUNTED ELEVATION -TOILET ELEVATION -TOILET ELEVATION -MIRROR PAPER TOWEL DISPENSER.PLAN -PAPER TOWEL DISP.& WASTE RECEPTACLE SIGNAGE ELEVATION -LAVATORY ELEVATION -EWC/DRINKING FOUNTAIN NOTES:1. DETAILS ABOVE ARE TO BE USED FOR MINIMUM ADA CLEARANCES. 2. TOILET ROOM ACCESSORIES BY OWNER U.O.N.3. HANDICAP ACCESS MOUNTING DIMENSIONS ARE VERY CRITICAL AND HAVE NO MINUS TOLERANCES.4. ALL DIMENSIONS SHOWN ARE FROM FACE OF FINISH. FINISH THICKNESS MUST BE ADDED TO ANY ROUGH-IN DIMENSIONS.5. PROVIDE BLOCKING AS REQUIRED IN ALL WALLS FOR INSTALLATION OF TOILET ROOM ACCESSORIES.6. VERIFY ALL MOUNTING HEIGHT REQUIREMENTS WITH LOCAL BUILDING CODES.7. ANSI REQUIRES A MIN. OF 18 " VERTICAL GRAB BAR IN ADDITION TO HORIZONTAL GRAB BARS IN ACCESSIBLE TOILET & TRANSFER TYPE SHOWER STALLS . PROVIDE AS REQUIRED. 1' - 6" 0' - 6" MAX MIN 1' - 5" FOLDING SHOWER SEAT GRAB BAR OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA 5' - 0" MIN 3' - 0" MIN MIN 2' - 0"MIN1' - 0" 16"-18"MIN1' - 0"3' - 6" MAX59" MIN. FLOOR-MOUNTED56" MIN. WALL-HUNGWHEEL CHAIR ACCESSIBLE WATER CLOSETS AMBULATORY ACCESSIBLE WATER CLOSETS 16"-18"17"-19"SEE NOTE #7 39"- 41"39"- 41"MIN.1' - 6"2' - 9"7"-9"MIN.1' - 3"TOILET PAPERHOLDERMAX.1' - 7"SOAP DISPENSER FIRE EXTINGUISHER Transfer Type Shower Compartment Size and Clearance seat wall 915 36 (back wall)91536 (control wall)1220 48 min 91536 minSEE NOTE #7 4 max1525 60 min 76030 min76030 minback wall sidewall sidewall Standard Roll-In TypeShower CompartmentSize and Clearance controls 27 max FOLDING SHOWER SEAT Alternate Roll-In TypeShower CompartmentSize and Clearance 91536 min915 36 min 1525 60 min back wall sidewall sidewall controls 27 maxMIN1' - 2"MIN4' - 0"MIN 3' - 0" HC WALL HUNGURINAL PLAN -URINAL X ≥ 2' - 0"(J) LATCH APPROACH, PUSH SIDE (A) FRONT APPROACH, PULL SIDE (K) LATCH APPROACH, PUSH SIDE, DOOR PROVIDED WITH CLOSER (I) LATCH APPROACH, PULL SIDE,DOOR PROVIDED WITH CLOSER (C) FRONT APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH (D) HINGE APPROACH, PULL SIDE (E) HINGE APPROACH, PULL SIDE (F) HINGE APPROACH, PUSH SIDE (G) HINGE APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH (H) LATCH APPROACH, PULL SIDE (B) FRONT APPROACH PUSH SIDE MIN 1' - 6"MIN5' - 0"MIN 1' - 0"MIN4' - 0"MIN4' - 0"MIN 3' - 0"MIN5' - 0"MIN4' - 6"MIN 3' - 6"MIN3' - 6"MIN 1' - 10"MIN4' - 0"MIN 1' - 10" MIN 2' - 0"MIN4' - 6"MIN 2' - 0" MIN 2' - 0"MIN3' - 6"MIN 2' - 0"MIN4' - 0"MIN4' - 0"MAX 2' - 0"2' - 8" MIN3' - 0" MINCLEAR WIDTH OF AN ACCESSIBLE ROUTE MIN 4' - 0" MIN 2' - 0" CLEAR WIDTH AT 180° TURN 3' - 6" MIN x < 48 3' - 6" MIN (A) 180 DEGREE TURN (B) 180 DEGREE TURN(EXCEPTION) 3' - 0" MIN x < 48 3' - 0" MIN4' - 0" MIN5' - 0" MIN2' - 6" MIN4' - 0" MIN SIZE OF CLEAR FLOOR SPACE 2' - 6" MIN4' - 0" MINPOSITION OF CLEAR FLOOR SPACE (A) FORWARD 4' - 0" MIN2' - 6" MIN(B) PARALLEL 3' - 0" MINx > 24MANEUVERING CLEARANCE IN AN ALCOVEX > 155' - 0" MIN (A) FORWARD APPROACH (B) PARALLEL APPROACH 4' - 0" MAXMIN1' - 3"UNOBSTRUCTED FORWARD REACH 3' - 8" MAX4' - 0" MAXOBSTRUCTED HIGH FORWARD REACH MAX 1' - 8">20-25 MAX (A)(B) MAX 0' - 10" UNOBSTRUCTED SIDE REACH MIN1' - 3"4' - 0" MAX2' - 10" MAXOBSTRUCTED HIGH SIDE REACH MAX 0' - 10"4' - 0" MAX3' - 10" MAX> 10-24 MAX 2' - 10" MAX(A)(B) SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 LIFE SAFETY CODE SUMMARY JAX22070 JULY 25 2022 G101 1/4" = 1'-0"1 ADA - FIXTURE ACCESSIBILITY 1/4" = 1'-0"2 ADA - MANEUVERING CLEARANCES @DOORS 1/4" = 1'-0"3 ADA - CLEAR WIDTH OF AN ACCESSIBLEROUTE/ 180° TURN 1/4" = 1'-0"4 ADA - CLEARANCE FLOOR SPACE 1/4" = 1'-0"5 ADA - REACH RANGES No Date Description 0 July 252022 Permit Issue WH PROJECT DESCRIPTION OFFICE BUILDINGOCCUPANCY: MERCANTILE OCCUPANCY -GROUP M BUILDING DATALOCATION:363 ATLANTIC BLVD UNIT 9, ATLANTIC BEACH, FL, 32233CONSTRUCTION TYPE: III-ASPRINKLERED: NONUMBER OF FLOOR: 1TOTAL AREA: 786 S.F. CODE INFORMATION JURISDICTION: JACKSONVILLE -DUVAL-COUNTY APPLICABLE CODES BUILDING CODE: FLORIDA BUILDING CODE 2020 7TH EDITION BUILDINGFLORIDA BUILDING CODE 2020 7TH EDITION EXISTING BUILDINGFLORIDA BUILDING CODE 2020 7TH EDITION ENERGY CONSERVATION MECHANICAL CODE: FLORIDA BUILDING CODE 2020 7TH EDITION MECHANICALPLUMBING CODE: FLORIDA BUILDING CODE 2020 7TH EDITION PLUMBING ELECTRICAL CODE: NFPA 70 NATIONAL ELECTRIC CODE 2020 LIFE SAFETY: NFPA 101 LIFE SAFETY CODE 2018 EDITIONFIRE: FLORIDA FIRE PREVENTION CODE 7TH EDITION -BASED OFF NFPA 1 AND NFPA 101 2018 EDITION ACCESSIBILITY CODE: FLORIDA BUILDING CODE 2020 7TH EDITION ACCESSIBILITY NOTES 1. SCOPE OF PROJECT INVOLVES A LEVEL III ALTERATION OF A 786 S.F. INTERIOR TENANT BUILD OUT FOR A TEA SHOPPE. WORK INCLUDES MECHANICAL, ELECTRICAL, AND PLUMBING; EXISTING BATHROOM TO REMAIN AS-IS, NEW PREP AREA, NEW CUSTOMER COUNTERTOP, AND FINISHES THROUGHOUT.2. TO THE BEST OF OUR KNOWLEDGE, INFORMATION, AND INTENT, BUILDING ALTERATIONS WERE DESIGNED TO AND COMPLY WITH THE APPLICABLE CODES LISTED ABOVE.3. INSPECTION OF EXISTING RATED WALLS BY ARCHITECT IS A LIMITED OBSERVATION AND DOES NOT CONFIRM THE ENTIRE EXISTING ASSEMBLY CONDITION. ADDITIONAL WORK MAY BE REQUIRED IF, DURING ANY CONSTRUCTION PHASE, THE WALL/CEILING IS DETERMINED TO BE DEFICIENT INCLUDING BUT LIMITED TO:A. FIRE CAULK ALL PIPE PENETRATIONS FOR METAL PIPES AND PVC.B. SEAL WALL TO METAL DECK PER REQUIREMENTS.C. FILL ANY HOLES IN WALL MISSING GYPSUM WALL BOARD WITH 5/8" FIRE RATED GYPSUM WALL BOARD PER REQUIREMENTS.4. ALL VISIBLE EMERGENCY LIGHTS AND EXIT SIGNS OBSERVED ARE INDICATED ON PLAN. OWNER SHALL PROVIDE ADDITIONAL FIXTURES AS INDICATED ON LIFE SAFETY PLAN..5. OWNER SHALL VERIFY BATTERY BACKUP CIRCUITS ARE PRESENT & MEET THE REQUIREMENTS OF NFPA 101 7.8 AND FBC 1008.3. PROVIDE IF NECESSARY. 6. CONTRACTOR SHALL PROVIDE TACTILE SIGNAGE PER NFPA 101 7.10.1.3. READING "EXIT" AT ALL EXTERIOR DOORS.7. CONTRACTOR SHALL PROVIDE ELECTRICAL SERVICE DISCONNECT & SIGNAGE PER NFPA 70 230.70 & NFPA 1 11.1.7.8. ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 101 SECTION 7.8 AND FBC 1008.3.9. ALL NEW INTERIOR FINISHES SHALL COMPLY WITH NFPA 101 10.2 AND FBC 803 & 804 CODE REFERENCE FLORIDA BUILDING CODECHAPTER 8. INTERIOR FINISH REQUIREMENTS SECTION 803.1.1 FINISH REQUIREMENTS TABLE 803.11 MERCANTILE OCCUPANCY -NON -SPRINKLEREDEXITS: CLASS-A, FLAME SPREAD 0-25; SMOKE DEVELOPED INDEX 0-450EXIT ACCESS: CLASS-B, FLAME SPREAD 26-75; SMOKE DEVELOPED INDEX 0-450OTHER SPACES: CLASS-C, FLAME SPREAD 76-200; SMOKE DEVELOPED INDEX 0-450 CHAPTER 9. FIRE PROTECTION REQUIREMENTSSEE NFPA 10(1-6) FIRE EXTINGUISHER REQUIREMENTS FOR MORE DETAILS TABLE 906.3.(1) FIRE EXTINGUISHERS FOR CLASS A HAZARDS -LIGHT-LOW HAZARD OCCUPANCYMAXIMUM AREA PER EXTINGUISHER: 11,250 SQ. FT.MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER: 75 FT SECTION 907.2.2 GROUP BMANUAL FIRE ALARM SYSTEMS SHALL BE INSTALLED WITH AN OCCUPANT LOAD OF 500 OR MORE, OR WHEN THE OCCUPANCY LOAD IS MORE THAN 100 PERSONS ABOVE OR BELOW THE LOWEST LEVEL OF EXIT DISCHARGE CHAPTER 10. MEANS OF EGRESSSECTION 1003 GENERAL MEANS OF EGRESS 1003.2 CEILING HEIGHT: REQUIRED: 7'-6" MIN. 1003.3 PROTRUDING OBJECTS1003.3.1 MINIMUM HEADROOM AT MEANS OF EGRESS DOORS REQUIRED: 6'-8" MIN, 6'-6" DOOR CLOSER1003.3.2 POST-MOUNTED OBJECTSREQUIRED: 4" MAX1003.3.3 HORIZONTAL PROJECTIONSREQUIRED: 4" MAX1003.3.4 CLEAR WIDTHPROTRUDING OBJECTS SHALL NOT REDUCED THE MINIMUM CLEAR WIDTH OF ACCESSIBLE ROUTES 1003.4 FLOOR SURFACEWALKING SURFACES OF THE MEANS OF EGRESS SHALL HAVE A SLIP-RESISTANT SURFACE AND BE SECURELY ATTACHED 1003.5 ELEVATION CHANGELESS THAN 12": SLOPED SURFACESSLOPE GRATER THAN 1:20, PROVIDE RAMPLESS THAN 6: RAMP REQUIRES HANDRAILS OR FLOOR FINISH MATERIAL THAT CONTRAST WITH ADJACENT FLOOR FINISHEXCEPTIONS: OCCUPANCY LOAD. TABLE 1004.5SEE CODE SUMMARY SCHEDULES: MEANS OF EGRESS TABLE EGRESS WIDTH. SECTION 1005SEE MEANS OF EGRESS SCHEDULE FOR ACTUAL MINIMUM EGRESS WIDTH REQUIRED BASED ON OCCUPANCY LOAD SECTION 1005.3.1 AND 1005.3.2 EGRESS WIDTH PER PERSON SECTION 1005.3.1. STAIRS:0.3" / OCCUPANT SECTION 1005.3.2 OTHER EGRESS COMPONENTS: 0.2" /OCCUPANT SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYSTABLE 1006.2.1. SPACES WTH ONE EXIT OR EXIT ACCESS DOORWAYS -COMMON PATH OF TRAVELMAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE (FT)MAXIMUM OCCUPANT LOAD OF SPACE WITHOUT SPRINKLER SYSTEM MERCANTILE 49 OCC L = 75<30 -75 >30 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY (1-500 OCC. LOAD)2 SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION1007.1.1 TWO EXITS OR EXITS DOORWAYSEXIT SEPARATION: ½ OF DIAGONAL OF THE LENTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN THEM. ≥1/2 MAX. DIAGONAL DISTANCE= MIN. SEPARATION REQUIRED: 1/2 X 51'-1" = 25'-7" , (ACTUAL) = 48'-10" SECTION 1008. MEANS OF EGRESS ILLUMINATION1008.2 ILLUMINATION REQUIRED. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED 1008.2.1 ILLUMINATION LEVEL. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE (11 LUX) AT THE WALKING SURFACE LEVEL. 1008.3 EMERGENCY POWER FOR ILLUMINATION. SECTION 1009 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESIBLE MEANS OF EGRESS SHALL BE PROVIDED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE, ACCESSIBILITY. TABLE 404.2.4.1 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATESA MINIMUM 18" UNOBSTRUCTED MANEUVERING CLEARANCE ON PULL SIDE OF DOOR(S).A MINIMUM 12" UNOBSTRUCTED MANEUVERING CLEARANCE ON PUSH SIDE OF DOOR(S) IF DOOR HAS BOTH A CLOSER AND LATCH. ACCESSIBLE COUNTER SURFACE NO MORE THAN 34" A.F.F. SECTION 604.5 GRAB BARS A MINIMUM 36" WIDE REAR GRAB BAR. A MINIMUM 42" LONG SIDE GRAB BAR.LEVER HARDWARE ON NEW OR RE-HUNG DOORS.NO KEY LOCKS ON EGRESS SIDE OF DOOR. SECTION 6 PLUMBING ELEMENTS AND FACILITIES. SECTION 1010 DOOR, GATES AND TURNSTILESSECTION 1010.1.1 THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL PROVIDE A MINIMUM CLEAR OPENING WIDTH OF 32 INCHES SECTION 1011 STAIRWAYS1011.2 WIDTH AND CAPACITY. THE REQUIRED CAPACITY OF STAIRWAYS SHALL BE DETERMINED AS SPECIFIED IN SECTION 1005.1, BUT THE MINIMUM WIDTH SHALL BE NOT LESS THAN 44 INCHES. SEE SECTION 1009 FOR ACCESSIBLE MEANS OF EGRESS STAIRWAYS. SECTION 1012 RAMPS1012.2 SLOPE. RAMPS USED AS PART OF A MEANS OF EGRESS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL (8-PERCENT SLOPE). THE SLOPE OF OTHER PEDESTRIAN RAMPS SHALL NOT BE STEEPER THAN ONE UNIT VERTICAL IN EIGHT UNITS HORIZONTAL (12.5-PERCENT SLOPE). 1012.6.3 LANDINGS. THE LANDING LENGTH SHALL BE 60 INCHESSECTION 1016 EXIT ACCESS SECTION 1018 AISLES SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS SECTION 1020. CORRIDORS TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING UNSPRINKLEREDMERCANTILE OCCUPANCY IF OCCUPANT LOAD SERVED BY CORRIDOR IS GREATER THAN 30 1 HOURSECTION 1020.2. MINIMUM CORRIDOR WIDTHANY FACILITIES MINIMUM WIDTH 44" INCHESWITH AN OCCUPANCY LOAD OF LESS THAN 50 36 INCHES SECTION 1020.4 DEAD END CORRIDOR: UNSPRINKLEREDMAXIMUM DEAD END CORRIDOR 20' SECTION 1022 EXITS ONCE A GIVEN LEVEL OF EXIT PROTECTION IS ACHIEVED, SUCH LEVEL OF PROTECTION SHALL NOT BE REDUCED UNTIL ARRIVAL AT THE EXIT DISCHARGE. EXITS SHALL BE CONTINUOUS FROM THE POINT OF ENTRY INTO THE EXIT TO THE EXIT DISCHARGE. SEE CODE SUMMARY SCHEDULES: OCCUPANCY LOADNUMBER OF EXITS PROVIDED AND EXITS DISCHARGE PROVIDED CHAPTER 11. ACCESSIBILITYSECTION 1103.1. WHERE REQUIRED.SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR PERMANENT, SHALL BE ACCESSIBLE TO PERSONS WHIT PHYSICAL DISABILITIES CODE REFERENCE NFPA OCCUPANCY AND CONSTRUCTION TYPEOCCUPANCY TYPE SUB-CLASSIFICATION: OCCUPANCY, PER NFPA 6.1. MERCANTILE, PER NFPA 101 A6.1.10.1-4 RESTAURANT WITH FEWER THAN 50 PERSONSCONSTRUCTION TYPE:TYPE III PER NFPA 220 4.4, NON-SPRINKLEREDTOTAL AREA: 786 G.S.F. TRAVEL DISTANCEGROUP 'M' MERCANTILE, NON-SPRINKLERED MAXIMUM COMMON PATH OF TRAVEL ALLOWED:75'-0", PER NFPA 101 36.2.5.3 LOW OR ORDINARY HAZARD MAXIMUM TRAVEL DISTANCE ALLOWED: (ACTUAL) =47'-0"150'-0" PER NFPA 101 36.2.6.1 ORDINARY HAZARD75'-0" PER NFPA 101 36.2.6.3 HIGH HAZARD MAXIMUM DEAD END CORRIDOR DISTANCE ALLOWED: (ACTUAL) = 020'-0" PER NFPA 101 36.2.5.2.2 EXITS (BASED ON HIGHER SEAT COUNT) EXIT UNITS REQ'D = 22 X .2" = 4.4" (32" MIN)2 EXITS REQUIRED PER NFPA 101 7.4.1.1PROVIDED 2 EXITS = 64" TOTAL EXIT UNITSMIN. SEPARATION BETWEEN EXITS≥1/2 MAX. DIAGONAL DISTANCE PER NFPA 101 7.5.4.2MIN. SEPARATION REQUIRED: 1/2 X 51'-1" = 25'-7" , (ACTUAL) = 48'-10" LIFE SAFETY LEGEND 1iLength 101(Occupancy Load Served Per Door Egress Width)Doors Clear Width EXIT EGRESS DOOR TAG CLEAR SPACE REQUIRED PATH OF TRAVEL PRIMARY EGRESS PATH. MAINTAIN 44" CLEAR DIMENSION ALONG ENTIRE PATH OF TRAVEL EXPEPT WHERE NOTED FIRE EXTINGUISHER 1i A 1 Occupancy Legend MERCANTILE GROUP M B EXISTINGRESTROOM 103 PREP AREA 102CORRIDOR 101 47'PoT 1 102(170) 389 SF PREP AREA MERCANTILE GROUP M KITCHENS, COMMERCIAL 232 SF SEATING AREA MERCANTILE GROUP MASSEMBLY WITHOUT FIXEDSEATS -UNCONCENTRATED 164 SF Area MERCANTILE GROUP M MERCANTILE 51' - 1 13/16"48' - 10 11/16"25'PoT 2 2 NEW 2 HOUR FIRE RATED BARRIER U421. SEE SHEET G103 EXISTING 1 HOUR FIRE RATED PARTITION 4 A601 3 A601 100(170) SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 LIFE SAFETY FLOOR PLAN JAX22070 JULY 25 2022 G102 No Date Description 0 July 252022 Permit Issue 1 Sept 292022 Revision 1 N SERENE ADVANCED SKIN CARE TREATA TEA SHOPPE 14 THE CANDLE GARDEN STORE 13 12 11 10 9 8 7 6 5 4 3 2 1 KEY PLAN MEANS OF EGRESS WIDTH FUNCTION OF SPACE OCCUPIED AREAAREA PER OCCUPANTOCCUPANCY LOADWIDTH PER OCC.MIN. WIDTH IN INCHESCOMMENTS MEANS OFEGRESS 1ST FLOOR MERCANTILE GROUP M ASSEMBLY WITHOUTFIXED SEATS -UNCONCENTRATED 232 SF 15 SF 15 0.2 3 KITCHENS,COMMERCIAL 389 SF 200 SF 2 0.2 0.4 MERCANTILE 164 SF 30 SF 5 0.2 1 786 SF 22 4.4 Grand total 786 SF 22 4.4 EXITS PROVIDED - 1ST LEVEL MARK OCC. SERVED PER DOORWIDTH 1ST FLOOR BUSINESS 100 170 102 170 Grand total: 2 MARK OCCUPANCY TRAVELDISTANCE MAX.TRAVELDISTANCE SPRINKLERED COMMENTS 1ST FLOOR PoT 1 MERCANTILE 47' 75' No PoT 2 MERCANTILE 25' 75' No TOTAL BUILDING AREAS OCCUPANCY OCC. AREA COMMENTS 1ST FLOOR MERCANTILE GROUP M 786 SF 786 SF 1/4" = 1'-0"1 LIFE SAFETY PLAN 1 1 1 1 1 1 1 1 U421 -NON BEARING WALL ASSEMBLY SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET DesignerGABRIEL ARANGO License No.-AR93416 ASSEMBLY DETAILS JAX22070 JULY 25 2022 G103 No Date Description 1 Sept 292022 Revision 1 1 1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE START OF WORK. THE DESIGNER DOES NOT ASSUME LIABILITY FOR ANY ERRORS AND OR OMISSIONS, ALL GOVERNING CODES AND REGULATIONS SHALL SUPERSEDE THESE DRAWINGS 2. DIMENSIONS INDICATED ARE NOT FIELD DIMENSIONS AND ARE PROVIDED FOR BIDDING PURPOSES ONLY. THEY MAY VARY DEPENDING UPON ACTUAL LOCATION AND EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL FIELD CONFIRM FOR ACCURACY BEFORE STARTING CONSTRUCTION. 3. THOROUGHLY CLEAN AND PREP ALL EXISTING SURFACES TO REMAIN AS REQUIRED TO ACCEPT NEW FINISH MATERIALS. TYPICAL FOR CEILINGS, FLOORS AND WALLS. 4. CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AFFECTED BY DEMOLITION AND NEW CONSTRUCTION. NO ADDITIONAL COSTS WILL BE PAID BY THE OWNER UNLESS VERIFIED (VIA RFI) DURING THE BIDDING PROCESS. 5. CONTRACTOR SHALL REPAIR AND REFINISH ALL CONTRACTOR RELATED DAMAGES AND RELATED AREAS AFFECTED BY RENOVATION WORK BACK TO THEIR ORIGINAL CONDITION AS NEW AND IN AN ACCEPTABLE MANNER TO OWNER / ARCHITECT. 6. IF THE CONTRACTOR DURING THE COURSE OF HIS CONTRACTED WORK ENCOUNTERS MATERIAL(S) CONTAINING ASBESTOS, HE IS TO STOP WORK IN THAT AREA AND IMMEDIATELY CONTACT THE OWNER'S REPRESENTATIVE. 7. ALL EXISTING AREAS ADJACENT TO RENOVATED AREAS SHALL BE PAINTED / REFINISHED "NEW" TO MATCH ADJACENT RENOVATED FINISH AND CONDITIONS. MATERIALS AND COLORS TO BE PROVIDED BY OWNER. 8. REFER TO MEP DRAWINGS FOR ALL ELECTRICAL, MECHANICAL AND PLUMBING DEMOLITION. A 1 2 A601 1 A601 1 B 2 2 3 4 1 1 5 EXISTING 1 HOUR FIRE RATED PARTITION EXISTING 1 HOUR FIRE RATED PARTITION SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 1RST FLOOR DEMOLITION PLAN JAX22070 JULY 25 2022 D110 MARK DESCRIPTION 1 REMOVE ALL INTERIOR PARTITIONS, DOORS, FLOOR FINISHES AS REQUIRED FOR NEW WORK. 2 EXISTING RESTROOM WALLS, CEILING, LIGHT FIXTURES AND TOILET TO REMAIN AS -IS. 3 EXISTING ELECTRICAL PANELS TO REMAIN AS-IS 4 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTING 5 EXISTING OUT SWING DOOR TO BE REUSED. CHANGE SWING. REUSE EXISTING HARDWARE AND FRAMEAS REQUIRED 1/4" = 1'-0"2 1ST FLOOR DEMOLITION PLAN No Date Description 0 July 252022 Permit Issue 1 Sept 292022 Revision 1 1 1 WH A 1 2 A601 1 A601 2 16' - 1 3/4"48' - 6"7' - 5"5' - 6 3/4" 11' - 11 3/8" 3' - 0"4' - 7"14' - 7"14' - 5 1/2"5' - 0"21' - 0 5/8"6' - 4 1/8"3' - 0"10' - 2 1/8" 3' - 10 3/4"12' - 3" 2' - 10" 1 3 4 5 9 6 12 11 13 25 14 10 7 8 8 15 16 18 17 19 20212223 24 26 27 14' - 3 7/8"3' - 0"28 B SEATING AREA 100 PREP AREA 102 CORRIDOR 101 EXISTING RESTROOM 103 102(170) 103 2 1B 1B 1B 1B 1B.2 NEW 2 HOUR FIRE RATED BARRIER U421. SEE SHEET G103 EXISTING 1 HOUR FIRE RATED PARTITION 1B.1 1B.2 1B.1 4 A601 3 A601 A401 1 3' - 0"A401 6 100(170) 3' - 0 1/2"28' - 4"0' - 10" 3A 3A 1B 3A 1B 1B 1.0 GENERAL REQUIREMENTS: 1.0.2 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHOP DRAWINGS AND SUBMITTALS REQUIRED BY JURISDICTION FOR PERMITTING AND FINAL INSPECTIONS. THESE MAY INCLUDE BUT ARE NOT LIMITED TO FIRE ALARM, SPRINKLER, LOW VOLTAGE WORK ETC. ALL LIGHT FIXTURES AND FINISH MATERIALS WILL REQUIRE FULL PRODUCT SUBMITTALS.1.0.3 INSTALLATION, SUBMITTAL REQUIREMENTS AND ADMINISTRATIVE REQUIREMENTS ARE TO BE PROVIDED PER SPECIFICATIONS SHEET OR MANUAL. IF NEITHER IS PROVIDED, PLEASE CONTACT ARCHITECT IMMEDIATELY FOR VERIFICATION.1.0.4 CONTRACTOR TO THOROUGHLY FIELD VERIFY SITE PRIOR TO PRICING TO INSURE FIELD CONDITIONS, DIMENSIONS AND QUANTITIES ARE CONSIDERED IN PREPARATION OF FINAL COSTS AND CONSTRUCTABLITY.1.0.5 CONTRACTOR TO VERIFY PENETRATIONS THROUGH PARTITIONS (SUCH AS DUCTWORK ETC.) TO INSURE THAT ADEQUATE BRACING AND REINFORCEMENT ARE PROVIDED.1.0.6 CONTRACTOR SHALL PROVIDE LABOR + MATERIAL AS REQUIRED FOR WORK WHICH MAY NOT FALL INTO JURISDICTION OF A SPECIFIC TRADE BUT IS REQUIRED FOR PROPER JOB EXECUTION AND COMPLETION OF CONSTRUCTION.1.0.7 CONTRACTOR AND VENDORS SHALL DETERMINE AVAILABILITY OF ALL MATERIALS. ANY DELIVERY SCHEDULE THAT MAY CAUSE COORDINATION ISSUES DURING CONSTRUCTION / INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY, FOR POSSIBLE RE-EVALUATION OF MATERIAL DESIGNATION. 1.1 GENERAL PARTITION NOTES: 1.1.1 REFER TO GENERAL PARTITION STANDARDS FOR TYPICAL INFORMATION.1.1.2 THE PARTITION ABOVE DOORS SHALL BE OF SAME CONSTRUCTION AS THE ADJACENT PARTITION.1.1.3 CAULK GAPS WHERE INTERSECTIONS OF CONSTRUCTION ELEMENTS ARE NOT CRISP AND CONSISTENT. COORDINATE CAULKING & SEALING WITH SPECIFICATIONS SHEET OR MANUAL, INSTALL PER MANUFACTURERS INSTRUCTIONS. 1.1.4 A LEVEL FLOOR SHALL BE PROVIDED AT ALL DOORWAYS TO INSURE TOLERANCES IN DOOR DETAILS ARE MET. GC SHALL PROVIDE DOORS AND FRAMES FOR SCRIBE TO INSURE THAT UNDERCUT CLEARANCE PER DETAILS.1.1.5 CONTRACTOR SHALL VERIFY ALL EXISTING WALLS / DEMISING WALLS / CORE WALLS WHERE EXPOSED OR HIDDEN BEHIND NON-RATED MATERIAL IN ORDER TO PROVIDE INFILL AND PATCH ANY EXISTING OPENING TO MEET REQUIRED FIRE RATINGS.1.1.6 DIMENSIONS:A. SCALES AS STATED ARE VALID ON THE ORIGINAL DRAWING ONLY. DO NOT SCALE FROM THESE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC PRESENTATION. DETAIL DIMENSIONS TAKE PRECEDENCE OVER PLAN DIMENSIONS.B. NOTIFY ARCHITECT OF ANY DIMENSIONAL DISCREPANCIES. ANY MODIFICATIONS OR DEVIATION TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR REVIEW AND APPROVAL.C. ALL VERTICAL DIMENSIONS SHALL BE TAKEN FROM A "BENCH MARK" OR OTHER SIMILAR GUIDE ESTABLISHED PRIOR TO THE START OF CONSTRUCTION. HIGH POINTS, LOW POINTS, IRREGULARITIES IN FLOOR SLAB WHICH COULD AFFECT FABRICATION / INSTALLATION, WORK OF OTHER TRADES OR VENDORS SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT.1.1.7 MATERIALS:A. INSTALL MOISTURE RESISTANT GWB AT AREAS EXPOSED TO MOISTURE INCLUDING BUT NOT LIMITED TO TOILETS, BREAKROOM COUNTERS AND OTHER SINK LOCATIONS.B. ALL NECESSARY WOOD BLOCKING / GROUNDS ETC. ARE TO BE FIRE RETARDANT TREATED. GC SHALL FULLY COORDINATE SETTING AND PLACEMENT TO THESE ELEMENTS AND INSURE THAT LOCAL CODE / BUILDING REQUIREMENTS ARE MET.C. GROUNDS / BLOCKING MAY NOT BE WHOLLY SHOWN ON DRAWING. STANDARD CONSTRUCTION PRACTICE SHALL GOVERN / DETERMINE SAID USE.D. INTERNAL WOOD BLOCKING SHALL BE PROVIDED FOR STURDY ANCHORAGE AT INTERSECTIONS OF WOOD PARTITIONS AND ADJACENT DRYWALL CONSTRUCTION. SUPPLY GRILLE RECESSED CAN LIGHT RETURN GRILLE EXHAUST FAN 2 X 4 PARABOLIC TROFFER PENDANT LIGHT EMERGENCY BATTERY UNITLIGHTING FIXTURE EXIT SIGN (TACTILE EXIT SIGNAGE A 1 2 A601 1 A601 B PREP AREA 102 EXISTINGRESTROOM 103 CORRIDOR 101 SEATING AREA 100 8' - 6" 8' - 6" 9' - 10" 9' - 10" 9' - 10" 8' - 10" 2 NEW 2 HOUR FIRE RATED BARRIER U421. SEE SHEET G103 EXISTING 1 HOUR FIRE RATED PARTITION PREP AREA 102 1A -ACT 2A-ACT 3A -GWB SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 OVERALL 1ST FLOOR PLAN & RCP JAX22070 JULY 25 2022 A110 1/4" = 1'-0"1 OVERALL 1ST FLOOR PLAN MARK Description 1 FRIDGE 2 ICE MACHINE 3 3 COMPARTMENT SINK 4 WATER HEATER 5 MOP SINK 6 WORK TABLE #1 7 CHEST FREEZER 8 INDUCTION BURNER 8 INDUCTION BURNER 9 WATER FILTER SYSTEM 10 HAND SINK 11 TOPPING FRIDGE 12 UNDER COUNTER FREEZER 13 UNDER COUNTER FRIDGE 14 TEA STATION 15 DROP-IN KITCHEN SINK 16 DROP IN ICE BIN 17 SEALING MACHINE #1 OVER HIGH TOP 18 SUGAR MACHINE 19 RO WATER SYSTEM UNDERCOUNTER. COORDINATE WITH SINK ANDFAUCET 20 HOT WATER DISPENSER 21 BLENDER 22 ESPRESSO MACHINE 23 BOBA WARMER 24 SEALING MACHINE #2 25 CASHIER P.O.S. 26 2 TV's MOUNTED FROM CEILING 27 WALL MOUNTED TV 28 2 DRAWERS BELOW P.O.S. FIELD VERIFY WIDTH 1/4" = 1'-0"3 REFLECTED CEILING PLAN 1ST FL No Date Description 0 July 252022 Permit Issue 1 Sept 292022 Revision 1 N SERENE ADVANCED SKIN CARE TREATA TEA SHOPPE 14 THE CANDLE GARDEN STORE 13 12 11 10 9 8 7 6 5 4 3 2 1 KEY PLAN 1 1 B 4 A601 3 A601 7' - 6"2' - 6" 6' - 0"1' - 2"2' - 6"8' - 6" PREP AREA 102 6' - 4"3' - 0"3' - 0"3' - 0"3' - 0 3/4"4' - 0"3' - 0"2' - 6"A401 2 3 A4015 4 UNDER COUNTER FRIDGE UNDER COUNTER FREEZER TOPPING FRIDGE 6' - 0" MDF OPEN CABINETS BELOW WITH PLASTIC LAMINATE FINISH ALL SURFACES QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD QUARTZ COUNTERTOP ON 3/4" PLYWOOD 2' - 8"5/8" GYPSUM BOARD OVER 3 5/8" 25 GA. METAL STUDS AT 16" O.C. BELOW COUNTERTOP 6' - 2 1/2" 6' - 1" 1ST FLOOR0' -0" 8' - 6"3' - 2"4' - 1" UNDER COUNTER FRIDGEPOLISHED STAINED CONCRETE FLOORS WOOD BASEBOARD. PAINT MDF SUPPORT WITH PLASTIC LAMINATE FINISH ALL SURFACES. COORDINATE WITH KITCHEN EQUIPMENT QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD OPEN MDF OPEN CABINET WITH PLASTIC LAMINATE FINISH ALL SURFACES MDF SUPPORT WITH PLASTIC LAMINATE FINISH ALL SURFACES. 1ST FLOOR0' -0" B POLISHED STAINED CONCRETE FLOORS WOOD BASEBOARD. PAINT MDF SUPPORT WITH PLASTIC LAMINATE FINISH ALL SURFACES. QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD OPEN MDF OPEN CABINET WITH PLASTIC LAMINATE FINISH ALL SURFACES 6' - 1" 6' - 0"3' - 2"4' - 10"1' - 8"QUARTZ COUNTERTOP ON 3/4" PLYWOOD 1ST FLOOR0' -0" POLISHED STAINED CONCRETE FLOORS WOOD BASEBOARD. PAINT MDF SUPPORT WITH PLASTIC LAMINATE FINISH ALL SURFACES. COORDINATE WITH KITCHEN EQUIPMENT QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD OPEN2' - 10"2' - 0"2' - 0" QUARTZ COUNTERTOP ON 3/4" PLYWOODMDF DRAWERS WITH PLASTIC LAMINATE FINISH ALL SURFACES UNDER COUNTER FREEZER MDF OPEN CABINET WITH PLASTIC LAMINATE FINISH ALL SURFACES 6' - 4"3' - 2"1ST FLOOR0' -0" UNDER COUNTER FRIDGE POLISHED STAINED CONCRETE FLOORS WOOD BASEBOARD. PAINT MDF SUPPORT WITH PLASTIC LAMINATE FINISH ALL SURFACES. COORDINATE WITH KITCHEN EQUIPMENT QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD OPENTOPPING FRIDGE OPEN MDF OPEN CABINET WITH PLASTIC LAMINATE FINISH ALL SURFACES 7' - 6"3' - 2"5/8" GYPSUM BOARD OVER 3 5/8" 25 GA. METAL STUDS AT 16" O.C.3' - 2"A 2 5' - 6 3/4"7' - 5"0' - 6"3' - 0"1' - 0"3' - 6"SURFACE MOUNTED SOAP DISPENSER ADA MIRROR (18" X 36")SURFACE MOUNTED PAPER TOWEL DISPENSER SURFACE MOUNTED TOILET PAPER DISPENSER 36" GRAB BAR 42" GRAB BAR SURFACE MOUNTED SANITARY NAPKIN DISPOSAL A4017 8 1' - 3"1ST FLOOR0' -0" 2 EXISTING8' - 10"2' - 10"3' - 6"1' - 0" 18" x 36" ADA MIRROR SURFACE MOUNTED SOAP DISPENSER 36" GRAB BAR 42" GRAB BAR SANITARY NAPKIN DISPOSAL TOILET PAPER DISPENSER PAPER TOWEL DISPENSER INSULATE OR COVER DRAIN WATER PIPING ON H.C. SINK 7' - 5" 1ST FLOOR0' -0" 36" GRAB BAR 42" GRAB BAR SANITARY NAPKIN DISPOSAL TOILET PAPER DISPENSER 2' - 10"0' - 6"3' - 0"EXISTING8' - 10"5' - 6 3/4" SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 ENLARGED PLANS JAX22070 JULY 25 2022 A401 No Date Description 0 July 252022 Permit Issue 1 Sept 292022 Revision 1 1/2" = 1'-0"1 ENLARGED PREP AREA 1/2" = 1'-0"2 Elevation 2 1/2" = 1'-0"3 Elevation 3 1/2" = 1'-0"4 Elevation 4 1/2" = 1'-0"5 Elevation 5 1/2" = 1'-0"6 ENLARGED RESTROOM 1/2" = 1'-0"7 Elevation 6 1/2" = 1'-0"8 Elevation 7 1 1 CLOSER CYLINDER 1 LOCK 3 HINGES DESCRIPTION HARDWARE # 1 (RESTROOM) MODEL # MANUFACTURER 1 4 1/2" X 4 1/2"STANLEY AUR 8702FL YALE YALE 400 SERIES PARALLEL ARM YALE ADA SIGN1 529 TRIMCO OR APPROVED EQUAL TYPE 1 -NON-BEARING GYPSUM BOARD NOTES:• METAL STUDS WITH 5/8" OR 1/2" GYPSUM WALLBOARDEACH SIDE, (TYPE X GYPSUM WALL BOARD AT RATED PARTITIONS)• INSULATION AS SCHEDULEDSEE SCHED WALL TYPE CATEGORY PARTITION TYPE FIRE RATED HOURS PARTITION TYPES 1A.2 SEE SCHEDSEE SCHEDSEE SCHED 1ST FLOOR0' -0" 12 A601 1RST FL CEILINGHEIGHT9' -10" ROOF DECK11' -9"1' - 8"2' - 7 1/8" 1' - 2" 2' - 6"3' - 2"2' - 10"2 8' - 6"A601 4 3' - 2"1ST FLOOR0' -0" A 1 A601 1RST FL CEILINGHEIGHT9' -10" ROOF DECK11' -9" B 8' - 5 1/2"4 A601 1ST FLOOR0' -0" 5/8" GYPSUM BOARD OVER 3 5/8" 25 GA. METAL STUDS AT 16" O.C. POLISHED STAINED CONCRETE FLOORS PATCH AND REPAIR EXISTING WALLS INVOLVED IN NEW CONSTRUCTION. PAINT WALLS AS REQUIRED MDF OPEN CABINET WITH PLASTIC LAMINATE FINISH ALL SURFACES (2) 2X4 TOP PLATE RUNNER TRACK SAME G.A. AS STUDS. SECURE TO SLAB W 3/4" POWER DRIVEN PIN @ 16" O.C. QUARTZ COUNTERTOP ON 3/4" PLYWOOD QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD 1' - 2"1' - 8"2' - 10"4' - 10"3' - 2"3' - 0" 0' - 5" 0' - 3 1/2" 3' - 0" MDF OPEN CABINET WITH PLASTIC LAMINATE FINISH ALL SURFACES 0' - 3 1/2"0' - 1"0' - 3 1/2"2' - 5"MDF DRAWER WITH PLASTIC LAMINATE FINISH ALL SURFACES WOOD BASEBOARD. PAINT QUARTZ COUNTERTOP ON 3/4" PLYWOOD 2' - 9"5/8" GYPSUM BOARD OVER 3 5/8" 25 GA. METAL STUDS AT 16" O.C. 1ST FLOOR0' -0" 1RST FL CEILINGHEIGHT9' -10" NEW 5/8" GYPSUM BOARD ON 3 5/8" METAL STUDS W/ BATT INSULATION FILL. PAINT POLISHED STAINED CONCRETE FLOORS BRACE STUDS BACK TO STRUCTURE AS REQUIRED ACOUSTICAL CEILING TILE AND GRID. PATCH AND REPAIR EXISTING RESTROOM WALLS INVOLVED IN NEW CONSTRUCTION. PAINT WALLS AS REQUIRED CORRIDOR 101 1/2" CEILING GRADE GYPSUM BOARD OVER 3 5/8" METAL STUDS @ 24" O.C. WOOD BASEBOARD. PAINT MDF SUPPORT WITH PLASTIC LAMINATE FINISH ALL SURFACES. COORDINATE WITH KITCHEN EQUIPMENT QUARTZ COUNTERTOP & BACKSPLASH ON 3/4" PLYWOOD 2' - 6" RUNNER TRACK SAME G.A. AS STUDS. SECURE TO SLAB W 3/4" POWER DRIVEN PIN @ 16" O.C. PREP AREA 102 3' - 2"HOLLOW METAL FRAME, ATTACHED W/ COUNTERSUNK SCREW. SEE SCHEDULE -SEALANT AROUND PERIMETER OF FRAME BOTH SIDES DOOR -SEE SCHEDULE CAULK ALL AROUND, BOTH SIDES 5/8" GWB OVER METAL STUDS SHEET NUMBER: PROJECT NO.: DRAWING TITLE: ISSUE DATE:TREATA TEA SHOPPEINTERIOR BUILD OUT363 ATLANTIC BLVD UNIT 9ATLANTIC BEACH, FL, 32233119424 BAYMEADOWS RDSUITE 250JACKSONVILLE, FL, 32256ALL CONSTRUCTION& DEVELOPERS NFPERMIT SET ArchitectGABRIEL ARANGO License No.-AR93416 SCHEDULES JAX22070 JULY 25 2022 A601 DOOR SCHEDULE MARK LOCATION DIMENSIONS FRAME COMMENTS DOOR PANEL SIZE THK DOOR PANEL PROPERTIES FRAMEMATERIAL DEPTHWIDTH HEIGHT TYPE DOOR MATERIAL 1ST FLOOR 100 SEATING AREA 3' - 0" 7' - 0" 0' - 1 3/4" FG GLASS ALUMINUM EXISTING OUT SWING DOOR TO BE REUSED. CHANGE SWING.REUSE EXISTING HARDWARE AND FRAME AS REQUIRED 101 CORRIDOR 0' - 0" 0' - 0" DOOR OPENING 102 PREP AREA 3' - 0" 7' - 0" 0' - 1 3/4" FHM HOLLOW METAL METAL EXISTING TO REMAIN AS-IS 103 EXISTING RESTROOM 3' - 0" 7' - 0" 0' - 1 3/4" FWD WOOD METAL HARDWARE #1 ROOM FINISH SCHEDULE ROOM No. ROOM NAME ROOM FINISH CEILING COMMENTSROOM AREA FLOOR BASE WALL CEILING CEILING HT 1ST FLOOR 100 SEATING AREA 233 SF POLISHEDCONCRETE WOOD BASE PAINT GYPSUM BOARD CEILING 9' - 10" 101 CORRIDOR 110 SF POLISHEDCONCRETE WOOD BASE PAINT GYPSUM BOARD CEILING 9' - 10" 102 PREP AREA 360 SF POLISHEDCONCRETE WOOD BASE PAINT ACOUSTICAL CEILING 8' - 6" WASHABLE KITCHEN ZONE TILES BY ARMSTRONG OR APPROVED EQUAL 103 EXISTINGRESTROOM 41 SF POLISHEDCONCRETE WOOD BASE PAINT ACOUSTICAL CEILING 8' - 10" EXISTING WALL SCHEDULE MARK THICKNESS FIRE RATING INSULATIONLAYER R-VALUE DESCRIPTION WALL CATEGORY TYPE 01 - INTERIOR PARTITIONS 1B 0' - 4 7/8" - 3 5/8" METAL STUD INSULATION FILL - 5/8" GYPSUM BOARD ON EACH SIDE - UP TO CEILING HEGHT 1B.2 0' - 6 1/8" 2 HOUR U421 EXISTING 3 5/8" METAL STUD WALL - ADD 2 LAYERS OF 5/8" GYPSUM BOARD OF TYPE "X" ON INTERIOR SIDE - FULL HEIGHT TO DECK ABOVE WALL CATEGORY TYPE 03 - PLUMBING CHASE 3A 0' - 4 1/4" - 3 5/8" METAL STUD - 5/8" MOISTURE RESISTANT GYPSUM BOARD ON ONE SIDE - UP TO CEILING HEIGHT CEILING SCHEDULE MARK AREA PRODUCT INFORMATION COMMENTSMANUFACTURER MODEL DESCRIPTION TYPE 01: SUSPENDED ACOUSTICAL CEILING TILE 1A - ACT 41 SF EXISTING 24" X 24" ACT SYSTEM TYPE 2: WASHABLE SUSPENDED ACOUSTICAL CEILING TILE 2A-ACT 336 SF ARMSTRONG KITCHEN ZONE 24"X24" ACT SYSTEM - WASHABLE OR APPROVED EQUAL TYPE 03: INTERIOR HARD CEILINGS - GWB 3A - GWB 337 SF 3 5/8" METAL STUD - 5/8" GYPSUMBOARD ON ONE SIDE No Date Description 0 July 252022 Permit Issue 1 Sept 292022 Revision 1 1/4" = 1'-0"1 BUILDING SECTION EAST WEST 1/4" = 1'-0"2 BUILDING SECTION NORTH SOUTH 1" = 1'-0"4 WALL & COUNTER SECTION1" = 1'-0"3 TYP. WALL SECTION 3" = 1'-0"5 HEAD/ JAMB - DOOR - HM FRAME @MTL. STUD 1