2220 Alicia Ln RES22-0290 truss repair permit 2 of 2alta engineering company www.altaengineeringco.com August 16, 2022 Michelle Foster via electronic mail to: Lmichelle.foster@lunspro.com LunsPro Services 830-13 A1A N., Ste. 278 Ponte Vedra Beach, Florida 32082 Roof Truss Evaluation & Repair Recommendations Bennett Residence 2220 Alicia Lane Atlantic Beach, Florida 32233 Alta Engineering Company was requested to evaluate the altered wood roof truss located east of the pantry attic access scuttle of the subject home in Atlantic Beach, Florida. The purpose of our evaluation was to provide guidance for the repair of the truss. The subject truss is the 6th hip truss from the west roof edge jack trusses. A diagonal web member was apparently removed from the subject truss to allow for installation of the air handling unit (AHU) mounted in the attic. Repair of the truss is required and should be completed as follows: 1. Remove the remaining portions of the cut web member from their connection to the truss press plates. 2. Install a new diagonal web member to snugly fit in place of the removed web member. The new truss chord shall be a kind size #2 SYP wood board. 3. Install new 3/4-inch thick CDX plywood gussets to join the replaced web members to the existing top and bottom chords. a. Gussets shall be provided on both sides of the truss where connected to the top chord; however, only one gusset can be installed at the connection to the bottom chord due to the spacial constraint imposed by the AHU on its east side. Roof Truss Evaluation August 16, 2022 LunsPro: Bennett Res. Page 2 b. The (2) top gussets shall be lap onto all joined members a minimum of 18-inches and have (8) #10 screws into each member. c. The single bottom gusset shall be lap onto all joined members a minimum of 24-inches and have (16) #10 screws into each member. Take care to space screws >3/4-inches from the edge of the board and a minimum of 2-inches apart. 4. In addition to replacing the removed truss web, also add ¾-inch thick CDX plywood gussets to each side of the quadruple vertical web members just south of the AHU. The gusset should be horizontally sized to match the width of the stacked webs and vertically sized 24-inches. Install (8) #10 screws to each web member. We appreciate the opportunity to provide our professional services. Please contact us if there are any questions concerning this report. Sincerely, alta engineering company Florida Board of Professional Engineers Certificate of Authorization No. 29095 Brett D. Newkirk, P.E. Licensed, Florida 62476 Principal This item has been electronically signed and sealed by Brett Newkirk, P.E. on the date adjacent to the seal using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies.