Loading...
4-10-23 Attachment AAttachment A to 4-10-23 Minutes History•Designed by Robert Morgan with input from Chip Drysdale•Cert. of Occupancy was issued in July 1999•Designed as a two story building with an observation deck on the roof•History of water leaks from observation deck•History of water leaks under second floor east and south windows•Lifeguards returning to service in the spring have to wipe down surfaces because of surface mold on walls and counter tops Attachment A to 4-10-23 Minutes Renovation 2018•Repair long term damage to roof and 2ndfloor windows because of water leaks and resulting wood rot•Enclosing 3rdfloor was a cost effective way to gain some office space•Spring 2018 construction began•Extensive water leaks in station during construction project•Fall 2018 work substantially complete in station•December 2018, concern of strong mold odor on 2ndfloor so Environmental Engineer contracted•1stMold Remediation by contractor•March 2019 environmental testing positive for mold•2ndMold Remediation by contractor•April 2019 environmental testing positive for mold•3rd mold Remediation by contractorAttachment A to 4-10-23 Minutes Water leak on 2ndFloorAttachment A to 4-10-23 Minutes Diagram of areas identified with un‐remediated moldAttachment A to 4-10-23 Minutes Diagram of areas identified with un‐remediated moldAttachment A to 4-10-23 Minutes Challenges in current building•The structure was designed in 1999 when operational needs were less•Currently there are 18 Lifeguards working per day•Up to 4 times a summer we have 20 kids in the Junior lifeguard program that need the use of the building for 5 days per group of 20•When guards and camp kids need to be sheltered from lightening and storms they all have to use the lifeguard station •There is one small bathroom for all employees (camp kids) and an outdoor shower for then to use•Not enough equipment storage space in the current building•No space for in‐service training•We know there are on going mold problems in the 2ndfloor wallsAttachment A to 4-10-23 Minutes First Floor Attachment A to 4-10-23 Minutes Attachment A to 4-10-23 Minutes Storage Trailer for Junior LG ProgramAttachment A to 4-10-23 Minutes Trailer for Jet Ski storageAttachment A to 4-10-23 Minutes Example of storage Jax Bch Ocean RescueAttachment A to 4-10-23 Minutes Junior LG Camp 2ndFloorAttachment A to 4-10-23 Minutes Wet equipment stored in stationAttachment A to 4-10-23 Minutes Equipment in StairwellAttachment A to 4-10-23 Minutes LG Training 2ndFloorAttachment A to 4-10-23 Minutes Equipment Stored Under Porch DeckAttachment A to 4-10-23 Minutes