TECO-Atlantic Village Plaza_SignedREVISIONSNO.DATEPROJECT NO.DRAWN BY:CHECKED BY:DATE:CERTIFICATE OF AUTHORIZATION NO. 28658SHEETNO.FLORIDA P.E. LICENSE NO. 65247MICHAEL J. YURO, P.E.REGISTERED PROFESSIONALPREPARED FOR:Y23 - 1221Yuro&Associates, LLCEIDMJY7/24/23145 Hilden Road, Unit 108Ponte Vedra, FL 32081(904) 342-5199TECO- PEOPLES GAS SYSTEMS, INC. 1ATLANTIC VILLAGE PLAZA - GAS MAIN REPLACEMENTCOVER SHEETPROFESSIONALENGIN
E
E R
L
I
CENSENo. 65247STATE OFFLORIDAM
I
CHAELJ.YUROPRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEALED AND THE SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY:ON THE DATE ADJACENT TO THE SEALRCALL 48 HOURS BEFORE YOU DIG IN FLORIDAIT'S THE LAW!SUNSHINE STATE ONE CALL OF FLORIDA, INC.1-800-432-4770NOTES:1) THE LOCATION OF EXISTING UTILITIES & RIGHT OF WAY IS BASED ON LIMITED INVESTIGATION TECHNIQUES AND SHOULD BE CONSIDERED APPROXIMATE ONLY. TECO CONTRACTOR TO CONTACT AND NOTIFY ALL UTILITY OWNERS PRIOR TO PERFORMING WORK ADJACENT TO THEIR FACILITIES.2) ALL RESTORATION TO MEET THE REQUIREMENTS OF THE PERMITTING AGENCY.3) ROAD CROSSING TO BE DIRECTIONAL BORED.4) ALL DISTURBED SIDEWALK TO BE REPLACED JOINT TO JOINT.5) FDOT STANDARD PLAN 102-602 & 102-660 TO BE USED FOR MOT.6) INSTALLATION TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE "TECO PEOPLES GAS - CONSTRUCTION STANDARDS MANUAL"SHEET INDEX1.COVER SHEET2.CREEK CROSSING3.SITE PLAN4.NOTES AND DETAILS5 - 6. MOT SHEETSRCALL 48 HOURS BEFORE YOU DIG IN FLORIDAIT'S THE LAW!SUNSHINE STATE ONE CALL OF FLORIDA, INC.1-800-432-4770CITY OF ATLANTIC BEACH - R/W PERMIT(SECTION 38, TOWNSHIP 02S, RANGE 29E)PERMIT SUBMITTAL 7/24/2023TIE IN TO EXISTING 2"PLASTIC GAS MAINPROPOSED 2" PLASTIC GAS MAIN(TO BE BORED)MAX REAMER = 3"ROADWAY WIDTH = ±41'AQUATIC DRIVECROSSINGLOOKING NORTHNot To Scale 48"(min.)R/W
R/WRIGHT OF WAY WIDTH = ±60' 48"(min.)THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004. F.A.C.PROJECT LOCATIONGAS
GASEXISTING 2" PE GAS MAIN(TO BE RETIRED)EXISTING 2" PE GAS MAIN(TO REMAIN)GASGASGASGAS
PROPOSED 1.25" PE GAS SERVICEPROPOSED 2" PE GAS MAINEXISTING 2" PE GAS MAIN(TO REMAIN)SCALE: 1"=250'ATLANTIC BLVD.AQUATIC DRIVESHEET NO. 3ATLANTIC VILLAGE PLAZAROYAL PALMS DRIVEPROPOSED DOUBLE 8' X 6' CULVERT(TO BE INSTALLED BY OTHERS)GGEXISTING CREEK(TO BE WIDENED & RE-GRADED)
REVISIONSNO.DATEPROJECT NO.DRAWN BY:CHECKED BY:DATE:CERTIFICATE OF AUTHORIZATION NO. 28658SHEETNO.FLORIDA P.E. LICENSE NO. 65247MICHAEL J. YURO, P.E.REGISTERED PROFESSIONALPREPARED FOR:Y23 - 1221Yuro&Associates, LLCEIDMJY7/24/23145 Hilden Road, Unit 108Ponte Vedra, FL 32081(904) 342-5199TECO- PEOPLES GAS SYSTEMS, INC. 2ATLANTIC VILLAGE PLAZA - GAS MAIN REPLACEMENTCREEK CROSSINGTIE IN TO EXISTING 2"PLASTIC GAS MAINPROPOSED 2" PLASTIC MAIN(TO BE BORED)MAX REAMER = 3"ROADWAY WIDTH = ±41'AQUATIC DRIVE 48"(min.)R/W
R/WRIGHT OF WAY WIDTH = ±60'EXIST. 36" CMPINV: ±1.60 48"(min.)THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004. F.A.C. 24"(min.)PROPOSED CONC. MAT FINISHED GRADEBOT: ± (-1.00)CREEK CROSSINGLOOKING NORTHNot To ScaleTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MICHAEL J. YURO, PE
ON THE DATE ADJACENT TO THE SEAL.
PRINTED C0PIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 36"(min.)PROPOSED TOP ELEV: ±6.0PROPOSED TOP ELEV: ±6.0EXISTING GRADEBOT: ±0.8MAINTAIN 24" MIN. SEPARATIONNOTE:1.MAINTAIN 24" MIN. SEPARATION BELOW CREEK BOTTOM FINISHED GRADE
XXXXXXXX
X
X
X
XD
SSSSSSSSSSW
W
W
W
W
W
W
WWWW
WW
WWW W W WW WOHE OHE OHE
UGEOHE OHE OHE OHE OHEOHEOHE OHE OHEGASGASGASGASGASGASGASGASGGGG
GGGGGGGGGGGGGGGASGAS
GAS
GAS
GASGASGASGASUGE
UGE
UGE
UGE
UGE
UGEUGEUGEUGEUGEUG
E
UGEUGEUGEUGEAPARTMENTSAPARTMENTSOHE W W
HYDGASREVISIONSNO.DATEPROJECT NO.DRAWN BY:CHECKED BY:DATE:CERTIFICATE OF AUTHORIZATION NO. 28658SHEETNO.FLORIDA P.E. LICENSE NO. 65247MICHAEL J. YURO, P.E.REGISTERED PROFESSIONALPREPARED FOR:Y23 - 1221Yuro&Associates, LLCEIDMJY7/24/23145 Hilden Road, Unit 108Ponte Vedra, FL 32081(904) 342-5199TECO- PEOPLES GAS SYSTEMS, INC. 3ATLANTIC VILLAGE PLAZA - GAS MAIN REPLACEMENTSITE PLANTHE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004. F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MICHAEL J. YURO, PE
ON THE DATE ADJACENT TO THE SEAL.
PRINTED C0PIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIESNOTE:1.DIMENSIONS TO GAS LINES ARE FROM EDGE OFPAVEMENT (EOP).2.EXISTING INFORMATION SHOWN ON THESEDRAWINGS, INCLUDING RIGHT OF WAY & EXISTINGUTILITIES, ARE APPROXIMATE ONLY. CONTRACTORTO VERIFY EXISTING INFORMATION ASNECESSARY.3.MAINTAIN 24" MINIMUM SEPARATION FROM ALLUTILITIES & STORM STRUCTURESINSTALL ±656 LF OF PROPOSED 2"PE GAS MAIN VIA DIRECTIONALDRILL WITH MIN. 36" COVERINSTALL PROPOSED 1.25" PEGAS SERVICEINSTALL PROPOSED 1.25" PEGAS SERVICETIE-IN TO EXISTING 2"PE GASMAIN W/ 2" 3-WAY TEE& 1.25" TEMP. BYPASSINSTALL 2" VALVECUT & CAPCUT & CAPEXISTING 2" PE GAS MAIN(TO BE RETIRED)±4'±4'±4'±7'4'x8' EXCAVATION±4'±2'±2'EXIST. 8" SEWERTOP: ±7.31 INV: ±1.22EXIST. 8" SEWERTOP: ±7.10 INV: ±1.05PROP. STORM INLETTOP: ±7.00 BOT: ±(-1.00)PROP. DOUBLE 8' x 6' CULVERTEXIST. 36' CMP(TO BE REMOVED BY OTHERS)TOP: ±6.00INV: ±1.60AQUATIC DRIVE R/WR/W±60'±45'EOP EOPEOP
EOP
EOP
SCALE: 1"=40'ATLANTIC VILLAGE PLAZASPEED BUMPPROP. SHEET PILE WALLPROP. GUARD RAILPROPANE TANKPROPANE TANKEXIST. CONC. FLUMEEXIST. CREEK EXIST. CREEK EXIST. CREEK±10'±4'±4'E
X
I
S
T
.
C
R
E
E
KMAINTAIN 48" MINIMUMCOVER UNDER PAVEMENTEOPR/WR/W EXISTING 2" PE GAS MAIN(TO REMAIN)EXISTING 2" PE GAS MAIN(TO REMAIN)±30'EXIST. 8' x 6' CULVERTMAINTAIN 24" MINIMUMSEPARATIONMAINTAIN 24" MINIMUMSEPARATION±26'TIE-IN TO EXISTING 2"PEGAS MAIN W/ 2" 3-WAY TEE& 1.25" TEMP. BYPASSCONC. REPAIR±28'±19'5 4 3 2 1 0 -1543210-1 PROP. RE-GRADING(TO BE DONE BY OTHERS)±49'PROP. CONCRETE MATTRESS(TO BE DONE BY OTHERS)
REVISIONSNO.DATEPROJECT NO.DRAWN BY:CHECKED BY:DATE:CERTIFICATE OF AUTHORIZATION NO. 28658SHEETNO.FLORIDA P.E. LICENSE NO. 65247MICHAEL J. YURO, P.E.REGISTERED PROFESSIONALPREPARED FOR:Y23 - 1221Yuro&Associates, LLCEIDMJY7/24/23145 Hilden Road, Unit 108Ponte Vedra, FL 32081(904) 342-5199TECO- PEOPLES GAS SYSTEMS, INC. 4ATLANTIC VILLAGE PLAZA - GAS MAIN REPLACEMENTUTILITY CONTACT INFORMATION(CONTRACTOR TO VERIFY CURRENT CONTACT INFORMATION)COMCAST CABLE (904) 738-6898CITY OF ATLANTIC BEACH (904) 247-5875BEACHES ENERGY SERVICES (904) 247-6252CITY OF NEPTUNE BEACH (904) 270-2423IQ FIBER (407) 722-2300JACKSONVILLE ELECTRIC AUTHORITY (904) 665-5703MCI (800) 624-9675 Ext: 2CROWN CASTLE (888) 632-0932 Ext: 2TECO PEOPLES GAS - JACKSONVILLE (813) 275-3783AT & T DISTRIBUTION G27896@ATT.COMUNITI FIBER LLC (251) 214-7059SUNSHINE DESIGN TICKET No. 130304103NOTES AND DETAILSPOTHOLE NOTES:1) CONTRACTOR TO CALL FOR UTILITY LOCATES & COMPLETE A "POTHOLE" AT EACH POTENTIAL CONFLICT/CROSSING TO IDENTIFY EXACT LOCATION & DEPTH OF EXISTING UTILITIES & DRAINAGE2) POTHOLE LOCATIONS SHOWN ON DETAIL ARE ESTIMATED...ACTUAL POTHOLE LOCATIONS TO BE DETERMINED IN FIELD BY CONTRACTOR3) ALL POTHOLES TO BE REPAIRED PER FDOT STANDARD INDEX NO. 125-001= 2'x2' POTHOLEPOTHOLETYPICAL DETAILNot To ScaleDDWWWWGASGASGASFOFOFOFOFOFOFOXXBT BT
FOFOGAS±4'END/BEGIN DIRECTIONAL DRILL(PER PLAN)PROPOSED PIPE TIE-INPROPOSED GAS BOREBORE ENTRY (ACTUAL)BORE EXIT (ACTUAL)±4'±6'±6' 36" (MIN)EXISTING GROUNDDIRECTIONAL BORE - END/BEGIN STATIONTYPICAL DETAILNot To Scale 36"
(MIN)PROPOSED GAS BORETHE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004. F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MICHAEL J. YURO, PE
ON THE DATE ADJACENT TO THE SEAL.
PRINTED C0PIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
REVISIONSNO.DATEPROJECT NO.DRAWN BY:CHECKED BY:DATE:CERTIFICATE OF AUTHORIZATION NO. 28658SHEETNO.FLORIDA P.E. LICENSE NO. 65247MICHAEL J. YURO, P.E.REGISTERED PROFESSIONALPREPARED FOR:Y23 - 1221Yuro&Associates, LLCEIDMJY7/24/23145 Hilden Road, Unit 108Ponte Vedra, FL 32081(904) 342-5199ATLANTIC VILLAGE PLAZA - GAS MAIN REPLACEMENTTECO- PEOPLES GAS SYSTEMS, INC. 5MOT SHEETSTHE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004. F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MICHAEL J. YURO, PE
ON THE DATE ADJACENT TO THE SEAL.
PRINTED C0PIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES
REVISIONSNO.DATEPROJECT NO.DRAWN BY:CHECKED BY:DATE:CERTIFICATE OF AUTHORIZATION NO. 28658SHEETNO.FLORIDA P.E. LICENSE NO. 65247MICHAEL J. YURO, P.E.REGISTERED PROFESSIONALPREPARED FOR:Y23 - 1221Yuro&Associates, LLCEIDMJY7/24/23145 Hilden Road, Unit 108Ponte Vedra, FL 32081(904) 342-5199ATLANTIC VILLAGE PLAZA - GAS MAIN REPLACEMENTTECO- PEOPLES GAS SYSTEMS, INC. 6MOT SHEETSTHE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004. F.A.C.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MICHAEL J. YURO, PE
ON THE DATE ADJACENT TO THE SEAL.
PRINTED C0PIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES