815 ATLANTIC BLVD COMM23-0055 Florida Juice n Bowl Plumbing Signed_1”HWCWWASTEVENTCONNECTION SCHEDULEDESCRIPTIONDESIGNATIONPLUMBING FIXTURE SCHEDULEP-1P-1P-2HAND SINK2"1/2"1/2"N/AP-3P-4P-5P-6ICE BIN2"N/AN/AN/AP-7TRENCH DRAIN3"N/AN/A1 1/2"P-9FLOOR SINK3"N/AN/AP-8P-103"1/2"N/AICE MACHINE1 1/2"P-11EXISTING LAVATORY2"1/2"1/2"1 1/2"P-12P-13P-14EXISTING WATER CLOSET3"1/2"N/A1 1/2"1 1/2"1 1/2"1/2"2"1/2"EXISTING MOP SINK1 1/2"1/2"1/2"2-COMPARTMENT SINKN/A1/2"3"1/2"UNDER COUNTER DISHWASHER2"1 1/2"1/2"1/2"3-COMPARTMENT SINKN/A1 1/2"1/2"1/2"2-COMPARTMENT SINKN/AWATER FILTER3/4"3/4"N/AWATER SOFTNER1"N/A1"N/AN/A3/4"EXISTING GAS WATER HEATERN/AN/AN/AP-15ALL APPLICABLE CODE REQUIREMENTS.UTILITY PROVIDER WITH PROTECTION FROM EXECESSIVE STRESS PEREXISTING GAS PIPE BELOW FINISHED GRADE. PROVIDED BY LOCAL GASG1UTILITY PROVIDER.EXISTING GAS METER AND STREET PRESSURE REGULATOR BY LOCAL GASG2G3CONNECTION REQUIREMENTS WITH EQUIPMENT MANUFACTURER.CONNECT TO KITCHEN EQUIPMENT WITH FLEXIBLE HOSE. PROVIDE WITHGAS PRESSURE REGULATOR AS REQUIRED. VERIFY GAS PRESSURE ANDG4DRIP LEG WITH DRAIN COCK PER APPLICABLE CODE REQUIREMENTS.G5GAS RISER DIAGRAMNOT TO SCALEGAS CONTROL VALVE, INTERLOCK WITH HOOD FIRE PROTECTION SYSTEM.VALVE FURNISHED BY HOOD FIRE PROTECTION SYSTEM MANUFACTURER,INSTALLED BY PLUMBING CONTRACTOR.GAS PIPE SIZING CALCSLONGEST RUN 30 LFDESIGN PRESSURE 10.5"W.C.GAS LOAD 290,000 BTUHREQ'D. PIPE SIZESYSTEM SIZED FOR 0.5 PSI WITH A PRESSURE DROP OF 10 PERCENT (O.6 SPECIFIC GRAVITY)AND A DELIVERY OF 0.5 PSI WITH 10.5" W.C. PER TABLES 402.2 AND 402.9 OF THE 2020 FLORIDAFUEL GAS CODE.0.5 PSI GAS PIPE SIZED FOR A TOTAL DEVELOPED LENGTH (TDL) OF 30'.MBH RATING FOR EQUIPMENT IS DETERMINED BY THE MANUFACTURER.FIXTUREBUILDING GAS DEMANDTOTAL MBHMARKCONN.1.5"290EACHMBHEACHQTY.ALLMBHE-4FRYERE-6GAS WATER HEATERGWH-1E-13/4"9020011E-2E-390200E-7E-8G2G5G130'1"(90cfh)(200 MBH)WATER HEATERG4FRYER(90 MBH)G3CONNECT TO WATER HEATER. PROVIDE WITH GAS PRESSUREREGULATOR AS REQUIRED. VERIFY CONNECTION REQUIREMENTSWITH EQUIPMENT MANUFACTURER.G6G63/4"GG
JASON CANNINGARCHITECT INCPROJECT ARCHITECTJason Canning hereby expressly reserves the rights to this drawing and it is not to be reproduced or copied in any format or manner whatsoever without first obtaining permission and consent.ARCHITECTURE PLANNING INTERIORSJASON T. CANNINGFLORIDA LICENSE NO. AR95310PROJECT TEAMARCHITECTJASON T. CANNING904.647.8690DATEISSUE09 27 2023PERMITTENANT IMPROVEMENT FOR
FLORIDA JUICE AND BOWL
815 ATLANTIC BLVD
ATLANTIC BEACH, FLORIDA 32233 12345DCBAPROJECT NO:DRAWN BY:CHECKED BY:SHEET NO:SHEET2303JBJTCDCBA123451812 Atlantic Blvd.Jacksonville, Florida 32207O: 904.647.8690C: 904.755.5589F: 904.406.7227jason@canningarch.comP1.008PLUMBINGS NOTES
FIXTURE SCHEDULE
DETAILS
CONNECT TOEXISTING SUPPLYSCALE: 1/4"=1'-0"02.5'5'10'NORTHSCALE: 1/4" = 1'-0"SUPPLY PLAN1P1.1P-1P-1P-2P-2P-3P-4P-5P-6P-7P-8P-9P-9P-10P-11P-14P-151"1/2" WATER RISER DIAGRAMNTSLEGENDHOT WATERCOLD WATER2P1.1EXISTINGTANKLESSGAS W/HCONNECT TOEXISTING SUPPLY3/4"1"1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
EXISTING
EXISTING EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
P-9P-9P-5P-8P-4P-3P-6P-7P-1P-2P-1P-2P-14P-151/2"1/2"1/2"1/2"3/4"3/4"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"1/2"BFP-1S
.
A
.
S
.
A
.PLUMBING SYSTEMS.A. PIPE MATERIALS: 1. DWV (DRAIN, WASTE, AND VENT) PIPING: FITTING SHALL BE LONG RADIUS FITTINGS, EXCEPT FITTING IN VENT PIPING MAY BE SHORT RADIUS FITTINGS. MINIMUM SIZE PIPING SHALL BE 2 INCHES FOR BURIED PIPING AND 1-1/4 INCHES FOR ABOVEGROUND PIPING. A. ABOVE AND BELOW GRADE: PVC, SCHEDULE 40, MEETING ASTM D1785, WITH SOLVENT WELD JOINTS MEETING ASTM D2564. 2. DOMESTIC WATER PIPING: A. BELOW GRADE: 1. COPPER, MEETING ASTM B88: TYPE K, COATED WITH COAL TAR SHELLAC, 955 SOLDERED JOINTS OR B. ABOVE GRADE: 1. CPVC, MEETING ASTM D2846 AND F441. PIPING UP TO 1-1/4" SHALL BE SCHEDULE 40. C. DIELECTRIC UNIONS: SHALL BE USED AT ALL JOINTS OF DISSIMILAR PIPE MATERIALS.B. PIPING INSULATION: 1. ELECTRIC WATER COOLER WASTE: A. 3/4-LB., 1-1/2 INCH BLANKET. B. FSK JACKET. 2. DOMESTIC HOT WATER MAINS AND RISERS: A. MINIMUM 1-INCH STANDARD FIBERGLASS. B. FACTORY JACKET AND FITTING COVERS. 3. DOMESTIC WATER PIPING EXPOSED TO EXTERIOR: NITRILE RUBBER BASED ELASTOMERIC SHEET INSULATION; ARMSTRONG "ARMAFLEX 2". MINIMUM INSULATION THICKNESS SHALL BE 3/4-INCH. 4. CPVC WATER PIPING AND PVC WASTE, VENT AND ROOF DRAIN PIPING RUN IN RETURN AIR PLENUMS: WRAP WITH A FIRE PROTECTIVE JACKET WITH A MAXIMUM FLAME SPREAD RATING OR 25 AND A SMOKE DEVELOPMENT RATING OF 50 IN ACCORDANCE WITH NFPA-90A, PARAGRAPHS 2-3.3.1 AND 2-3.10.1. 5. PIPING TO BE UNINSULATED: PIPING RUN-OUTS TO FIXTURES (EXCEPT AS NOTED FOR HANDICAP- ACCESSIBLE FIXTURES). C. ACCEPTABLE MANUFACTURERS: 1. MANUFACTURERS' MODEL NUMBERS ARE LISTED TO ESTABLISH A STANDARD OF QUALITY AND LEVEL OF PERFORMANCE 2. EQUIVALENT ITEMS OF THE FOLLOWING MANUFACTURERS ARE ACCEPTABLE: A. FIXTURE TRIM: SEE FIXTURE SCHEDULE 1. AMERICAN-STANDARD, KOHLER, SPEAKMAN, MOEN, DELTA, T&S BRASS, CHICAGO FAUCET SYMMONS, BRIGGS. 3. DRAIN AND FIXTURE SPECIALTIES: J.R. SMITH, JOSAM, ZURN. A. FLOOR AND EXTERIOR CLEANOUTS: ZURN-1440 OR EQUAL B. WALL CLEANOUTS: ZURN-1441 OR EQUAL W/ SMOOTH SECURED COVER. C. FLOOR DRAINS: SEE SCHEDULE. 4. WATER COOLERS: SEE FIXTURE SCHEDULE, OASIS, ELKAY, HALSEY TAYLOR. 5. WATER HEATERS: SEE FIXTURE SCHEDULE. 6. WATER SYSTEM SPECIALTIES. A. WATER HAMMER ARRESTORS SHALL CONFORM TO PDI WH201 AND ASSE 1010 ACCEPTABLE: ZURN SHOKTROLS Z-1700 OR EQUAL.PIPING SPECIALITIESA. ESCUTCHEONS SHALL BE MANUFACTURED WALL, CEILING AND FLOOR PLATES; DEEP-PATTERN TYPE WHERE REQUIRED TO CONCEAL PROTRUDING FITTINGS AND SLEEVES. CONSTRUCT OF ONE-PIECE CAST BRASS WITH POLISHED CHROME PLATE FINISH AND SET-SCREW.HANGERS AND SUPPORTSA. PROVIDE HANGERS, RODS, AND SUPPORT CLAMPS AS REQUIRED TO PROPERLY SUPPORT PIPING FROM STRUCTUREB. PROVIDE BUILDING ATTACHMENTS OR CONCRETE INSERTS APPROPRIATE FOR BUILDING MATERIALSSLEEVES:A. WALLS AND PARTITIONS: 1. PIPE SLEEVES 8-INCH DIAMETER AND SMALLER (ABOVE GRADE): SLEEVES SHALL BE MILD STEEL PIPE OR PLASTIC SLEEVES BUILT INTO WALL, PARTITION OR BEAM, SIZED TO PASS PIPING AND COVERING, LEAVING A CLEAR SPACE OF 1/4 -INCH MINIMUM BETWEEN COVERING AND SLEEVE. PENETRATIONS OF FIRE RATED BARRIERS SHALL HAVE MILD STEEL SLEEVES. 2. PIPE SLEEVES INSTALLED IN EXTERIOR WALLS BELOW GRADE: SCHEDULE 40 STEEL HOT DIPPED GALVANIZED AFTER FABRICATION OR CAST IRON SLEEVE WITH 1/4-INCH X 3-INCH CENTER FLANGE (WATER STOP) AROUND THE OUTSIDE.B. PIPE SLEEVES IN FLOORS (ABOVE GRADE): SLEEVES SHALL BE 14 GAUGE GALVANIZED SHEET STEEL OR PLASTIC, SET BEFORE FLOOR IS POURED, SIZED TO PASS PIPE AND COVERING, LEAVING A CLEAR SPACE OF 1/4-INCH BETWEEN COVERING AND SLEEVE, AND SHALL EXTEND 1/2-INCH ABOVE FINISHED FLOOR.C. SEALING OF SLEEVES: 1. SLEEVES BELOW GRADE: CAULK ANNULAR SPACE BETWEEN PIPE AND SLEEVE USING OAKUM AND POURED LEAD BOTH SIDES MINIMUM ONE INCH DEEP TO MAKE WALL PENETRATION WATER TIGHT. 2. SLEEVES ABOVE GRADE: OPENINGS AROUND PIPES, DUCT, ETC., PASSING THROUGH SLEEVES SHALL BE MADE DRAFT FREE AND VERMIN-PROOF BY PACKING SOLIDLY WITH MINERAL WOOL OR FIBERGLASS 3. SEALING OF SLEEVES THROUGH FIRE RATED BARRIERS: OPENINGS AROUND PIPES, ETC., THROUGH FIRE RATED BARRIERS SHALL BE SEALED USING AN U.L. APPROVED METHOD RATED AT LEAST EQUAL TO THE WALL BEING PENETRATED.INSTALL ONE (1) INCH THICKNESS PIPE INSULATION ON HOT WATER PIPING.PLUMBING GENERAL NOTES1. SEE SPECIFICATION FOR ADDITIONAL INFORMATION AND REQUIREMENTS.2. COORDINATE HVAC EQUIPMENT AND DUCT LOCATION WITH HVAC CONTRACTOR. SEE MECHDWGs. FOR ADDITIONAL INFORMATION.3. DO NOT INSTALL PIPING ABOVE ELECTRICAL PANELS OR EQUIPMENT. COORDINATE ELECTRICALPANEL AND EQUIPMENT LOCATION WITH ELECTRICAL CONTRACTOR.4. RUN ALL HORIZONTAL COLD & HOT WATER PIPING ABOVE CEILINGS UNLESS OTHERWISE NOTED.5. INSTALL ALL WORK IN A NEAT AND WORKMANLIKE MANNER, USING ONLY WORKMENTHOROUGHLY QUALIFIED IN THE TRADE OR DUTIES THEY ARE TO PERFORM. ROUGH WORK WILLBE REJECTED.6. MAINTAIN A MINIMUM 10' CLEARANCE BETWEEN HVAC EQUIPMENT FRESH AIR INTAKES ANDSANITARY VENTS.7. FIELD VERIFY ALL EXISTING PIPING AND PIPING CONNECTION SIZES AND LOCATIONS. EXCEPTOTHERWISE NOTED ON THE DRAWING, EXISTING CONCEALED PIPING NOT CONNECTED TO NEWPLUMBING SYSTEM OR FIXTURES SHALL BE CAPPED BEHIND FINISHED WALL OR BELOW FLOORAND ABANDONED IN PLACE.8. PROPERLY CONNECT NEW PLUMBING SYSTEM AND FIXTURES TO EXISTING SYSTEM. PROVIDENEW FITTINGS AS REQUIRED FOR PROPER CONNECTION. CLEAN ALL EXISTING SANITARY LINES.9. FIELD VERIFY EXISTING BUILDING STRUCTURAL. NOTIFY GENERAL CONTRACTOR FORRESOLUTION IF EXISTING BUILDING STRUCTURE IMPEDES PLUMBING INSTALLATION. SEESTRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND INSTRUCTION.10. DOMESTIC WATER SHUT-OFF VALVES LOCATED ABOVE DRYWALL CEILINGS SHALL BE GROUPEDTOGETHER TO PROVIDE ACCESS FROM SINGLE ACCESS PANELS IF POSSIBLE. PROVIDE WITHIDENTIFICATION TAG INDICATING AREAS THE VALVE CONTROLS.11. UNLESS OTHERWISE DIRECTED, ALL DOMESTIC WATER AND GAS PIPING SHALL BE LOCATED ASHIGH AS POSSIBLE, TIGHT TO BOTTOM OF STRUCTURE. UNLESS OTHERWISE DIRECTED, SANITARYAND VENT PIPING SHALL BE LOCATED AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF STRUCTURE,WITH MINIMUM SLOPE REQUIRED BY APPLICABLE CODE REQUIREMENTS.12. COORDINATE ALL LATERAL CONNECTIONS WITH CIVIL ENGINEERING DRAWINGS, ANYCONFLICTS TO BE RESOLVED PRIOR TO START OF CONSTRUCTION.13. CLEANOUTS ON 6" AND SMALLER PIPING SHALL BE PROVIDED WITH A CLEARANCE OF NOT LESSTHAN 18" FOR RODDING.14. HEAT TRAPS -- WATER-HEATING EQUIPMENT NOT SUPPLIED WITH INTEGRAL HEAT TRAPS ANDSERVING NONCIRCULATING SYSTEMS SHALL BE PROVIDED WITH HEAT TRAPS ON THE SUPPLY ANDDISCHARGE PIPING ASSOCIATED WITH THE EQUIPMENT.HEAT TRAPS ARE REQUIRED IN ACCORDANCE WITH FECC C404.315. INSULATION OF PIPING -- PIPING FROM A WATER HEATER TO THE TERMINATION OF THE HEATEDWATER FIXTURE SUPPLY PIPE SHALL BE INSULATED IN ACCORDANCE WITH TABLE C403.2.10 OFTHE FECC16. ON BOTH THE INLET AND OUTLET PIPING OF A STORAGE WATER HEATER OR HEATED WATERSTORAGE TANK, THE PIPING TO A HEAT TRAP OR THE FIRST 8 FEET (2438 MM) OF PIPING,WHICHEVER IS LESS, SHALL BE INSULATED.JASON CANNINGARCHITECT INCPROJECT ARCHITECTJason Canning hereby expressly reserves the rights to this drawing and it is not to be reproduced or copied in any format or manner whatsoever without first obtaining permission and consent.ARCHITECTURE PLANNING INTERIORSJASON T. CANNINGFLORIDA LICENSE NO. AR95310PROJECT TEAMARCHITECTJASON T. CANNING904.647.8690DATEISSUE09 27 2023PERMITTENANT IMPROVEMENT FOR
FLORIDA JUICE AND BOWL
815 ATLANTIC BLVD
ATLANTIC BEACH, FLORIDA 32233 12345DCBAPROJECT NO:DRAWN BY:CHECKED BY:SHEET NO:SHEET2303JBJTCDCBA123451812 Atlantic Blvd.Jacksonville, Florida 32207O: 904.647.8690C: 904.755.5589F: 904.406.7227jason@canningarch.comP1.108WATER SUPPLY PLAN
RISER DIAGRAM
NOTES
EXIST.GREASETRAPCONNECT TOEXISTING SEWERSERVICEEXISTING FIXTURESTO REMAINCOCOP-12P-12P-12P-12P-12P-13P-13P-13P-13P-1P-1P-2P-2P-3P-4P-5P-6P-7P-8P-9P-9P-10P-11P-14P-15SCALE: 1/4"=1'-0"02.5'5'10'NORTHSCALE: 1/4" = 1'-0"SANITARY PLAN1P1.23"3"3"3"3"EXISTING 4"3"3"3"3"3"3"3"3"C.O.C.O.EXISTING FIXTURESTO REMAINSANITARY AND VENT RISER DIAGRAMSLEGENDVENTWASTE2P1.2NTSGREASECONNECT TO EXISTINGSEWER SERVICE2" VTRP-11P-12P-9P-13P-13P-13P-13P-12P-8P-9P-12P-5P-12P-3P-6P-7P-12P-10P-14P-15COCO1 1/2"1 1/2"3"2"2"2"3"3"3"3"3"3"3"3"3/4"1"3"3"3"3"EXISTING 4"3"JASON CANNINGARCHITECT INCPROJECT ARCHITECTJason Canning hereby expressly reserves the rights to this drawing and it is not to be reproduced or copied in any format or manner whatsoever without first obtaining permission and consent.ARCHITECTURE PLANNING INTERIORSJASON T. CANNINGFLORIDA LICENSE NO. AR95310PROJECT TEAMARCHITECTJASON T. CANNING904.647.8690DATEISSUE09 27 2023PERMITTENANT IMPROVEMENT FOR
FLORIDA JUICE AND BOWL
815 ATLANTIC BLVD
ATLANTIC BEACH, FLORIDA 32233 12345DCBAPROJECT NO:DRAWN BY:CHECKED BY:SHEET NO:SHEET2303JBJTCDCBA123451812 Atlantic Blvd.Jacksonville, Florida 32207O: 904.647.8690C: 904.755.5589F: 904.406.7227jason@canningarch.comP1.209SANITARY PLAN
RISER DIAGRAM
NOTES