comm 23 0055 B - Fire Marshall ApprovedJason Canning Architect Inc Architecture, Planning, Interiors 1812 Atlantic Boulevard Jacksonville, FL 32207 O: (904) 647-8690 P: (904) 755-5589 F: (904) 406-7227 jason@canningarch.com To: Department of Planning and Development Re: Code Summary For: Florida Juice & Bowl 815 Atlantic Blvd, Jacksonville, FL CODE SUMMARY 1. USE AND OCCUPANCY CLASSIFICATION - (FBC-B: CHAPTER 3, SECTION 303.1.1) GROUP A2: ASSEMBLY (NFPA 101: A.6.1.2.1) ASSEMBLY OCCUPANCY: RESTAURANT 2. GENERAL BUILDING HEIGHTS AND AREAS - (FBC-B: CHAPTER 5) GROSS BUILDING AREA: 1,950 SF EXISTING No. OF STORIES ALLOWED: 1 No. OF STORIES PROVIDED: 1 EXISTING BUILDING MAX. SF ALLOWED: 6,000 SF EXISTING BUILDING BUILDING HEIGHT: EXISTING BUILDING; TENANT RENOVATION ONLY No. UNITS PER FLOOR: N/A MEZZANINE: NO 3. TYPES OF CONSTRUCTION - (FBC-B: CHAPTER 6) TYPE VB - EXISTING (FBC-B: TABLE 601) NON SPRINKLER-ED 4. ACCESSIBILITY-( 2017 FLORIDA ACCESSIBILITY CODE 6th EDITION) ADA COMPLIANT: YES 100% 5. INTERIOR FINISHES- (FBC-B: CHAPTER 8- TABLE 803.9) GROUP A2: NON SPRINKLER-ED EXIT PASSAGE: A FINISH CORRIDORS: A FINISH ROOMS ENCLOSED SPACE: B FINISH 6. MEANS OF EGRESS - (FBC-B: CHAPTER 10) TOTAL OCCUPANT LOAD = 74 (TABLE 1004.1.1) KITCHEN: 808 SF @ 100 SF/PERSON = 8 (NFPA 101.7.3.2.1) ASSEMBLY (TABLES & CHAIRS) INDOORS: 46 SEATS ASSEMBLY (TABLES & CHAIRS) EXTERIOR: 20 SEATS MEANS OF EGRESS - (NFPA 101.7.3.2.1) TOTAL OCCUPANT LOAD = 79 (TABLE 1004.1.1) KITCHEN: 808 SF @ 100 SF/PERSON = 8 (NFPA 101.7.3.2.1) ASSEMBLY (TABLES & CHAIRS) INDOORS: 767 SF @ 15 SF/PERSON = 51 (NFPA 101.7.3.2.1) ASSEMBLY (TABLES & CHAIRS) EXTERIOR: 300 SF @ 15 SF/PERSON = 20 (NFPA 101.7.3.2.1) EGRESS WIDTH PER OCCUPANT SERVED: 0.2 PER OCCUPANT= 11" (SECTION 1005) SPACES WITH ONE MEANS OF EGRESS (TABLE 1006.2.1) MAX LOAD = 49 MAX. TRAVEL DISTANCE TO AN EXIT: 200 FT WITHOUT SPRINKLER SYSTEM (TABLE 1017.2) MIN. NUMBER OF EXITS: (SECTION 1006.2.1) = 2 7. AUTOMATIC SPRINKLER SYSTEMS - (FBC-B: CHAPTER 9 - SECTION 903) NO SPRINKLER SYSTEM 8. PLUMBING SUMMARY: PLUMBING FIXTURE - (FBC-P: CHAPTER 4) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (FBC-P:TABLE 403.1) FIXTURES REQUIRED BASED ON TOTAL OCCUPANCY + PATIO: 74 PERSONS WATER CLOSETS: 1:75 MALE / FEMALE = 1 M / 1 F LAVATORIES: 1:200 MALE / FEMALE = 1 M / 1 F DRINKING FOUNTAIN: N/A SERVICE SINK: 1 REQUIRED (1 PROVIDED) NOTE: 1. EXISTING ACCESSIBLE PARKING SPACES AND RAMPS ARE IN PLACE. THE SIDEWALK IS FLUSH WITH THE FLOOR LEVEL OF THE INTERIOR SPACE AND THE THRESHOLD DOES NOT EXCEED THE HEIGHT LIMIT. 2. PROVIDE LIGHT GAUGE ROOF TRUSS SYSTEMS SYMBOL "R".