1099 ATLANTIC BLVD ROOF24-0017 Evaluation Report _ Polyglass REV. 3-19-24
® NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT P.E. EVALUATION REPORT (PEER) Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 PEER-PLYG-001.B.R17 FL1654-R33 (HVHZ) Date of Issuance: 12/12/2013 Revision 17: 10/04/2023 SCOPE: This P.E. Evaluation Report (henceforth ‘PEER’) is issued under F.A.C. Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 8th Edition (2023) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted herein. DESCRIPTION: Polyglass Modified Bitumen Roof Systems (HVHZ) LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This PEER is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our PEERs by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its PEER relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO P.E. Evaluated” may be displayed in advertising literature. If any portion of the PEER is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire PEER shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This PEER consists of pages 1 through 5, plus a 90-page Appendix. Prepared by: CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the PEERs are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this PEER, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC NEMO|etc. ® ©NEMO ETC, LLC PEER-PLYG-001.B.R17 Certificate of Authorization #32455 P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ FL1654-R33 (HVHZ) Polyglass Modified Bitumen Roof Systems Revision 17: 10/04/2023 BACK TO TOP Page 2 of 5 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Product Approval Method: Method 1, Option D – Codified Material, Evaluation by Engineer Compliance Statement: Polyglass Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 8th Edition (2023) Florida Building Code, High Velocity Hurricane Zone (HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations of Use set forth herein. 2. STANDARDS: SECTION PROPERTY STANDARD YEAR TAS 110 Resistance to Foot Traffic TAS 114, Section 8.9 2011 TAS 110 Wind resistance TAS 114, Appendix C, D or J 2011 TAS 110 Susceptibility to Hail Damage TAS 114, Appendix F 2011 TAS 110 Susceptibility to Leakage TAS 114, Appendix G 2011 TAS 110 Material standard ASTM D4601 2012 TAS 110 Material standard ASTM D4897 2016 TAS 110 Material standard ASTM D6162 2016 TAS 110 Material standard ASTM D6163 2016 TAS 110 Material standard ASTM D6164 2016 TAS 110 Material standard ASTM D6222 2016 TAS 110 Material standard ASTM D6509 2016 3. REFERENCES: ENTITY EXAM REFERENCE DATE ENTITY EXAM REFERENCE DATE ERD (TST6049) ASTM D6163 P37590.03.13-2-R1 02/05/13 FM (TST1867) FM 4470 0D3A3.AM 04/04/97 ERD (TST6049) ASTM D6164 P37590.03.13-3A 03/06/13 FM (TST1867) FM 4470 2B8A4.AM 07/02/97 ERD (TST6049) ASTM D6163 (T2) P33960.05.14 05/08/14 FM (TST1867) FM 4470 2D0A0.AM 12/23/98 ERD (TST6049) ASTM D6163/G155 P45440SC.03.15-1 03/31/15 FM (TST1867) FM 4470 2D5A9.AM 06/22/99 ERD (TST6049) ASTM D6163/G155 P45440SC.03.15-2-R1 03/31/15 FM (TST1867) FM 4470 3006646 01/04/00 ERD (TST6049) ASTM D6162 SC5170.05.15 05/08/15 FM (TST1867) FM 4470 3000857 01/12/00 ERD (TST6049) ASTM D6162 SC5170.12.15 12/29/15 FM (TST1867) FM 4470 3004091 01/12/00 NEMO (TST6049) ASTM D4897 4S-PLYG-18-002.11.18-2 11/16/18 FM (TST1867) FM 4470 3001334 02/15/00 NEMO (TST6049) ASTM D6164 4S-PLYG-18-002.11.18-3 11/28/18 FM (TST1867) FM 4470 3006115 05/02/01 NEMO (TST6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/19 FM (TST1867) FM 4470 3002416 02/07/02 NEMO (TST6049) ASTM D6162/G155 4S-PLYG-18-002.01.19-B 01/25/19 FM (TST1867) FM 4470 3012321 07/29/02 NEMO (TST6049) ASTM D6163 4S-PLYG-18-002.05.19-H 05/20/19 FM (TST1867) FM 4470 3014692 08/05/03 NEMO (TST6049) ASTM D6222/G155 4S-PLYG-18-002.05.19-C 05/20/19 FM (TST1867) FM 4470 3019317 06/30/04 NEMO (TST6049) ASTM D6222/G155 4S-PLYG-18-002.05.19-D 05/20/19 FM (TST1867) FM 4470 3020703 07/30/04 NEMO (TST6049) ASTM D6164 4S-PLYG-18-002.05.19-N 05/31/19 FM (TST1867) FM 4470/4474 3018332 01/31/06 NEMO (TST6049) ASTM D6164 4S-PLYG-18-002.08.19-I 09/06/19 FM (TST1867) FM 4470/4474 3023368 03/20/06 NEMO (TST6049) ASTM D6164/G155 4S-PLYG-18-002.09.19-J 09/06/19 FM (TST1867) FM 4470/4474 3022038 04/05/06 NEMO (TST6049) ASTM D4601 4q-PLYG-19-SSMBB-02.A 12/13/19 FM (TST1867) FM 4470/4474 3024594 05/23/06 NEMO (TST6049) ASTM D6164 4q-PLYG-19-SSMBB-04.A 01/02/20 FM (TST1867) FM 4470/4474 3023458 07/18/06 NEMO (TST6049) ASTM D6164/G155 4q-PLYG-19-SSMBB-04.B 01/02/20 FM (TST1867) FM 4470/4474 3025185 05/22/07 NEMO (TST6049) ASTM D6222/G155 4q-PLYG-19-SSMBB-05.A 07/23/20 FM (TST 1867) FM 4470/4474 3025185 05/22/07 NEMO (TST6049) ASTM D6164 4q-PLYG-20-SSMBB-04.A 10/21/20 FM (TST1867) FM 4470/4474 3030668 09/12/07 NEMO (TST6049) ASTM D6222/G155 4q-PLYG-19-SSMBB-05.A-R1 09/10/21 FM (TST1867) FM 4470/4474 3032172 06/12/09 NEMO (TST6049) ASTM D6163 (t2) 4q-PLYG-20-SSMBB-05.A 10/18/21 FM (TST1867) FM 4470/4474 3049631 04/21/14 NEMO (TST6049) ASTM D6164 4q-PLYG-22-SSMBB-04.A 04/21/23 FM (TST1867) FM 4470/4474 3057029 02/02/17 NEMO (TST6049) ASTM D6509 4q-PLYG-22-SSMBB-01.A 06/14/23 FM (TST1867) FM 4470 3001334 01/25/00 NEMO (TST6049) ASTM D6222/G155 4q-PLYG-22-SSMBB-01.B 06/14/23 FM (TST1867) FM 4470 3014751 08/27/03 NEMO (TST6049) ASTM D6222/G155 4q-PLYG-22-SSMBB-01.C 06/14/23 FM (TST1867) FM 4470 3007170 01/13/04 NEMO (TST6049) ASTM D4601 4q-PLYG-23-SSMBB.02.A 07/06/23 FM (TST 1867) Traceability PR461792 12/15/21 NEMO (TST6049) ASTM D6164/G155 4q-PLYG-22-SSMBB.01.D 07/28/23 FM (TST1867) FM 4470/4474 PR454230 (DATA) 01/26/22 PRI (TST5878) ASTM D4601 MSA-039-02-03 09/27/17 M-D (CER1592) Prop. for Rev. 10-0823 10/12/10 ERD (TST11294) TAS 114 PLYG-CTL13945.05.17-1 05/30/17 NEMO Traceability TFRM-0020-ICP 02/10/22 ERD (TST11294) TAS 114 PLYG-CTL13945.05.17-3 05/30/17 NEMO (TST6049) Criticality 4S-PLYG-18-001.06.18 06/23/18 ERD (TST6049) TAS 114 P13760.09.09 09/10/09 NEMO (TST6049) TAS 114 4L-PLYG-18-003.08.18 08/21/18 ERD (TST6049) TAS 114 P13770.09.09 09/10/09 NEMO (TST6049) Criticality 4S-PLYG-18-001.10.18 10/03/18 NEMO|etc. ® ©NEMO ETC, LLC PEER-PLYG-001.B.R17 Certificate of Authorization #32455 P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ FL1654-R33 (HVHZ) Polyglass Modified Bitumen Roof Systems Revision 17: 10/04/2023 BACK TO TOP Page 3 of 5 ENTITY EXAM REFERENCE DATE ENTITY EXAM REFERENCE DATE ERD (TST6049) TAS 114 P30540.11.09-R1 11/30/09 NEMO (TST6049) TAS 114 4L-PLYG-18-003.11.18 11/28/18 ERD (TST6049) TAS 114 P30550.12.09 12/02/09 NEMO (TST6049) TAS 114 4L-PLYG-18-003.01.19 01/11/19 ERD (TST6049) TAS 114 P33970.03.11 03/15/11 NEMO (TST6049) TAS 114 4L-PLYG-18-003.04.19-A 04/08/19 ERD (TST6049) TAS 114 P39680.03.13 03/04/13 NEMO (TST6049) TAS 114 4L-CEL-18-001.12.18-2 07/10/19 ERD (TST6049) TAS 114 P41630.08.13 08/06/13 NEMO (TST6049) Criticality 4S-PLYG-18-001.06.19.A 07/17/19 ERD (TST6049) TAS 114 SC6160.11.14 11/10/14 NEMO (TST6049) TAS 114 4a-CEL-19-LSWUS-01.B 09/17/19 ERD (TST6049) TAS 114 SC8085.05.15 05/19/15 NEMO (TST6049) TAS 114 4a-PLYG-20-LSWUS-01.A 08/28/20 ERD (TST6049) TAS 114 SC9455.15 04/01/16 NEMO (TST6049) TAS 114 4a-PLYG-20-LSWUS-02.A 10/05/20 ERD (TST6049) TAS 114 PLYG-SC8905.05.16-1 05/17/16 NEMO (TST6049) TAS 114 4a-PLYG-21-LSWUS-01.A 11/29/21 ERD (TST6049) TAS 114 PLYG-SC8905.05.16-2 05/17/16 NEMO (TST6049) FM 4474 4a-PLYG-23-LSWUS-02.A 09/07/23 ERD (TST6049) TAS 114 PLYG-SC12095.07.16 07/14/16 NEMO (TST6049) FM 4474 4a-PLYG-23-LSWUS-01.A 08/29/23 ERD (TST6049) TAS 114 PLYG-SC10815.07.16-R1 09/23/16 NEMO (TST6049) FM 4474 4a-PLYG-23-LSWUS-04.A 10/04/23 ERD (TST6049) TAS 114 PLYG-SC11475.16 11/17/16 PRI (TST5878) TAS 114 PUSA-188-02-01 02/08/17 ERD (TST6049) FM 4470/4474 PLYG-SC6070.12.16 12/20/16 PRI (TST5878) TAS 114 PUSA-188-02-02 02/08/17 ERD (TST6049) TAS 114 PLYG-SC13235.01.17 01/17/17 PRI (TST5878) TAS 114 PUSA-188-02-03 02/08/17 ERD (TST6049) TAS 114 PLYG-SC13920.05.17 05/30/17 PRI (TST5878) TAS 114 PUSA-202-02-01 05/17/17 ERD (TST6049) TAS 114 PLYG-SC13945.05.17 05/30/17 PRI (TST5878) TAS 114 PUSA-202-02-02 05/17/17 ERD (TST6049) TAS 114 PLYG-SC15760.09.17 09/11/17 NEMO Data Release DRA, CEL 10/04/23 FM (TST1867) FM 4470 2W7A7.AM 08/04/94 UL (QUA9625) Quality Control Service Confirm (FL) 08/16/22 FM (TST1867) FM 4470 1Z5A6.AM 10/25/96 UL (QUA9625) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: This PEER covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations of Use herein. TABLE 1: EVALUATED MEMBRANES TYPE PRODUCT MATERIAL STANDARD PLANT(S) REFERENCE TYPE GRADE BASE SHEETS Polyglass G2 Base ASTM D4601 II N/A AL Elastobase SA ASTM D4601 II N/A PA ModiFleece ASTM D4601 II N/A FL, TX Elastovent ASTM D4897 N/A N/A PA Polybase V (formerly “Polyglass Base”) ASTM D6509 N/A N/A FL APP, SMOOTH- SURFACE MEMBRANES Polybond ASTM D6222 I S FL Polyflex ASTM D6222 I S FL APP, GRANULE- SURFACE MEMBRANES Polybond G ASTM D6222 I G FL Polyflex G ASTM D6222 I G FL Polyflex G FR ASTM D6222 I G FL Polyfresko G ASTM D6222 I G NV Polyfresko G FR ASTM D6222 I G NV Polyflex SA P ASTM D6222 I G FL, TX Polyflex SA P FR ASTM D6222 I G TX Polyfresko G SA ASTM D6222 I G NV Polyfresko G SA FR ASTM D6222 I G NV SBS, SMOOTH-SURFACE MEMBRANES Elastoshield VP HT (formerly “Elastoshield HT”) ASTM D6162 III S FL Elastobase V (formerly “Elastobase”) ASTM D6163 I S FL Elastoflex V ASTM D6163 I S FL Elastoflex SA V ASTM D6163 I S FL, PA, TX Elastoflex SA V FR ASTM D6163 I S FL, PA, TX Elastoflex SA V Plus ASTM D6163 I S FL, TX NEMO|etc. ® ©NEMO ETC, LLC PEER-PLYG-001.B.R17 Certificate of Authorization #32455 P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ FL1654-R33 (HVHZ) Polyglass Modified Bitumen Roof Systems Revision 17: 10/04/2023 BACK TO TOP Page 4 of 5 TABLE 1: EVALUATED MEMBRANES TYPE PRODUCT MATERIAL STANDARD PLANT(S) REFERENCE TYPE GRADE SBS, SMOOTH-SURFACE MEMBRANES Elastoflex SA V Plus FR ASTM D6163 I S FL, TX Elastobase P ASTM D6164 I S FL, TX Elastoflex SA Base ASTM D6164 I S PA, TX Elastoflex S6 ASTM D6164 I S FL Elastoshield TS ASTM D6164 I S PA Elastoflex S6 HP ASTM D6164 II S NV SBS, GRANULE SURFACE MEMBRANES Elastoshield HT G ASTM D6162 III G FL Elastoshield HT G FR ASTM D6162 III G FL Elastoflex V G ASTM D6163 I G FL, PA Elastoflex V G FR ASTM D6163 I G FL, PA Elastoflex S6 G ASTM D6164 I G FL, PA Elastoflex S6 G FR ASTM D6164 I G FL Polyfresko G SBS ASTM D6164 I G NV Polyfresko G SBS FR ASTM D6164 I G NV Elastoshield TS G ASTM D6164 I G FL, TX Elastoshield TS G FR ASTM D6164 I G FL, TX Elastoflex SA P ASTM D6164 I G FL, TX Elastoflex SA P FR ASTM D6164 I G FL, TX Polyfresko G SBS SA ASTM D6164 I G NV Polyfresko G SBS SA FR ASTM D6164 I G NV 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this PEER, or previous versions thereof, is/was used for permitting or design guidance. PEERs are not to be construed as representing any attributes not specifically listed, nor are PEERs to be construed as an endorsement of the subject, or a recommendation for its use. There is no warranty by NEMO ETC, LLC or Robert Nieminen, P.E., express or implied, as to any finding or other matter in this PEER, or as to any product covered by the PEER. 5.2 This PEER is exclusively for use in High Velocity Hurricane Zone jurisdictions, as defined in FBC Chapter 2 (Broward and Miami-Dade Counties). 5.3 The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to ‘as-tested’ conditions under Testing Application Standard TAS 114, Appendix J. Roof decks shall be in accordance with FBC HVHZ requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This PEER does not include evaluation of fire classification. Refer to FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This PEER does not include evaluation of roof edge termination. Refer to Roofing Application Standard RAS 111 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC HVHZ 1521 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with Testing Application Standard TAS 105. NEMO|etc. ® ©NEMO ETC, LLC PEER-PLYG-001.B.R17 Certificate of Authorization #32455 P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ FL1654-R33 (HVHZ) Polyglass Modified Bitumen Roof Systems Revision 17: 10/04/2023 BACK TO TOP Page 5 of 5 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per Testing Application Standard TAS 114 has already been applied). Refer to FBC HVHZ 1620 and Roofing Application Standard RAS 128 for determination of design wind loads. 5.7.2 For mechanically attached components, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC HVHZ 1620 or Roofing Application Standard RAS 128. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Analysis shall be in accordance with Roofing Application Standard RAS 117 or RAS 137. *This extrapolation is not permitted for systems marked with an asterisk*. 5.7.3 For tables and/or assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation shall be applicable to all roof pressure zones. Rational analysis is not permitted. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this PEER. 6. INSTALLATION: Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations of Use noted herein. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL (QUA9625): (360) 817-5512; bsai.inspections@ul.com - THE 90-PAGES THAT FOLLOW FORM PART OF THIS PEER - NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 1 of 90 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 7 1B Wood New or Reroof (Tear-Off) B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 7 1C Wood New, Reroof (Tear-Off) or Recover B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12 1D Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 14 1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 17 1F Wood New or Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 21 1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 25 2A Steel or Structural Concrete New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 32 2B Steel or Structural Concrete New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 38 2C Steel or Structural Concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 43 2D Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mechanically Attached Velociflex, Bonded Roof Cover 45 3A Structural Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 48 3B Structural Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 61 4A Deck with Lightweight concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 62 4B Deck with Lightweight concrete New or Reroof (Tear-Off) B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68 4C Deck with Lightweight concrete New or Reroof (Tear-Off) E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 70 4D Deck with Lightweight concrete New or Reroof (Tear-Off) E-2 Mechanically Attached Thermal Barrier, Bonded Vapor Barrier, LWC, Mechanically Attached Base Sheet, Bonded Roof Cover 73 4E Deck with Lightweight concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 73 5A Cementitious wood fiber Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 75 5B Cementitious wood fiber Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 76 5C Cementitious wood fiber Reroof (Tear-Off) or Recover B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 77 5D Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 78 5E Cementitious wood fiber Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 78 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 79 6B Existing gypsum New, Reroof (Tear-Off) or Recover B-3 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 83 6C Existing gypsum New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 83 6D Existing gypsum New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 83 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 84 7B Various Recover F Non-Insulated, Bonded Roof Cover 90 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 2 of 90 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC HVHZ requirements to the satisfaction of the Authority Having Jurisdiction. Deck-attachment details pertain to ‘as-tested’ conditions under Testing Application Standard TAS 114, Appendix J. The table below provides reference to various as-tested deck sub-assemblies and associated maximum allowable design pressures. POLYGLASS AS-TESTED DECK ATTACHMENT DETAILS (TAS 114, APPENDIX J) TYPE TESTED SPAN (FT O.C.) TESTED FASTENER TESTED FASTENER SPACING (INCH O.C.) AS-TESTED ALLOWABLE PRESSURE (PSF) 15/32-inch APA rated CDX plywood 2 8d ring shank nails 6 -75.0 2 #10 wood screws 6 -90.0 2 #10 wood screws 4 -120.0 2 #8 wood screws 6 -127.5 2 ft o.c., and blocked 4 ft o.c. #10 wood screws 4 -142.5 19/32-inch APA rated CDX plywood 2 8d ring shank nails 6 -60.0 2 #10 wood screws 6 -127.5 22 ga., Type B, Grade 33 steel 6 #12 HWH Teks 5 6 -112.5 22 ga., Type B, Grade 40 steel 6 5/8” puddle welds 6 -97.5 6 #12 HWH Teks 5 with ¾” washers 6 -135.0 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fastener shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC HVHZ PARTS MINIMUM ENGAGEMENT Wood Altenloh, Brinck and Co. U.S., Inc. NOA 22-1214.02 Trufast #14 HD with Trufast 3” Metal Insulation Plate Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment OMG, Inc. NOA 23-0718.03 OMG #14 Heavy Duty with OMG 3 in. Round Metal Plate OMG #14 Roofgrip with OMG Accutrac Flat Bottom Polyglass USA N/A #14 Polygrip with 2 7/8 in. Polygrip Hex Plate SFS Group USA, Inc. NOA 22-0913.02 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3 Steel Altenloh, Brinck and Co. U.S., Inc. NOA 22-1214.02 Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate Minimum ¾-inch steel penetration and engage the top flute of the steel deck OMG, Inc. NOA 23-0718.03 OMG #14 Heavy Duty with OMG 3 in. Round Metal Plate OMG #12 Roofgrip, #14 Roofgrip or #15 Roofgrip with OMG Accutrac Flat Bottom Polyglass USA N/A #12 Polygrip, #14 Polygrip or #15 Polygrip with 2 7/8 in. Polygrip Hex Plate SFS Group USA, Inc. NOA 22-0913.02 Dekfast DF-#12-PH3, DF-#14-PH3 or DF-#15-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3 Structural Concrete Altenloh, Brinck and Co. U.S., Inc. NOA 22-1214.02 Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plate Minimum 1.25-inch embedment. Fastener installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions OMG, Inc. NOA 23-0718.03 OMG #14 Heavy Duty or CD-10 with OMG 3 in. Round Metal Plate OMG #14 Roofgrip with OMG Accutrac Flat Bottom Polyglass USA N/A #14 Polygrip with 2 7/8 in. Polygrip Hex Plate SFS Group USA, Inc. NOA 22-0913.02 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC HVHZ 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 3 of 90 4 Minimum 200 psi, minimum 2-inch thick FBC HVHZ Approved lightweight insulating concrete may be substituted for or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. 5 Preliminary insulation attachment: Unless otherwise noted, use FBC HVHZ Approved roofing fasteners; minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6 Unless otherwise noted, insulation adhesive application rates are as follows. ✓ Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ✓ If applying hot asphalt to concrete deck, deck shall be primed with ASTM D41 primer. ✓ When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. ✓ The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES BY FBC HVHZ ADHESIVE REFERENCE MINIMUM RATE Polyglass N/A Polyglass LRF M P-LRFM Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. Polyglass LRF M-PG P-LRFM-PG Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. Polyglass LRF CR P-LRF-CR Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. Dupont de Nemours FL720 INSTA STIK Quik Set Insulation Adhesive INSTA STIK Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. OMG, Inc. NOA 22-0519.04 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart, SpotShot or Canister) Generic, ASTM D312, Type IV N/A hot asphalt Full coverage at 25-30 lbs/square 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN. TAPERED THICKNESS (IN) MDP (PSF) LISTED PRODUCT FBC HVHZ P-LRFM Any polyisocyanurate listed with adhesive herein Various 0.5 -157.5 P-LRFM-PG Any polyisocyanurate listed with adhesive herein Various 0.5 -157.5 P-LRF-CR Any polyisocyanurate listed with adhesive herein Various 1.0 -117.5 OB500 Rmax Multi-Max FA3 NOA 22-0815.03 0.5 -45.0 OB500 Polytherm-H N/A 0.5 -315.0 OB500 Johns Manville ENRGY 3 NOA 18-0501.05 0.5 -315.0 OB500 Polytherm N/A 0.5 -487.5 8 Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9 For mechanically attached components, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC HVHZ 1620 or Roofing Application Standard RAS 128. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria in accordance with Roofing Application Standard RAS 117 or RAS 137. *This extrapolation is not permitted for systems marked with an asterisk* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 4 of 90 10 For tables and/or assemblies marked with an asterisk*, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance in accordance with Testing Application Standard TAS 105. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Should the fastener resistance be less than that required, a revised fastener spacing – prepared, signed and sealed by a qualified design professional in accordance with Roofing Application Standard RAS 117 or RAS 137 – may be submitted to the Building Official for review and acceptance. For systems using Trufast Versa-Fast, the number of Versa-Fast Fasteners installed through the Versa-Fast Plate may be increased from the minimum noted in order to yield minimum required withdrawal resistance. 12 Refer to FBC HVHZ 1521 for requirements and limitations regarding recover installations. For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS 124. 13 For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC HVHZ Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5). The separator component shall be documented as meeting FBC HVHZ 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC FBC HVHZ Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40 lbs/square Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. SBS-CA1 Base Ply One ply Elastobase V (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield VP HT PG350 at 1.5-2.0 gal/square Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed) SBS-CA2 Base Ply One ply Elastobase V (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP Polyplus 35 at 1.5-2.0 gal/square Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed) SBS-AA Base Ply or Ply One or more plies Elastobase V (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield VP HT Hot Asphalt at 20-40 lbs/square Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed) Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. SBS-TA Base Ply or Ply One or more plies Elastobase V (sand/poly), Elastobase V (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield VP HT, Elastoshield TS Torch-Applied Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (poly-film backed), Polyfresko G SBS FR (poly-film backed) SBS-SA-H Base Ply Elastobase SA Self-adhering (followed by torch-applied sheet) NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 5 of 90 MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-SA Base Ply One or more plies Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR, Elastoflex SA Base Self-Adhering Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Elastobase V or Elastobase P with a poly-film top surface. APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polybase V, Polyflex, Polybond Torch-Applied Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR APP-SA Cap Ply Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polyfresko G SA FR, Polykool Self-Adhering Note: Unless otherwise noted, permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Elastobase V or Elastobase P with a poly-film top surface. 15A DETEC Systems “TruGround® Conductive Primer” may be applied to DensDeck Prime and SECUROCK Gypsum-Fiber Roof Board with no adverse effect on system wind uplift performance. 15B Surfacing materials which hold current FBC Approval for use over modified bitumen membranes may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Polyglass or KM Coatings Florida Product Approval or Miami-Dade NOA for approved surfacing materials and a Roofing Materials Directory for fire ratings associated with surfacing usage. 16 Thermal Barrier and/or Vapor Barrier Options: 16A Structural Concrete Decks: The lesser of the MDP listings below vs. that for the selected assembly applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; ADHERED INSULATION OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE PER TABLE 3A (NOTES 6,7,8) MDP (PSF)* TYPE APPLICATION C-VB-1. PG100 Elastoflex SA V Plus Self-Adhering INSTA STIK or P-LRF-CR, 12-inch o.c. -60.0 C-VB-2. PG100 Polybase V Torch-applied INSTA STIK or P-LRF-CR, 12-inch o.c. -75.0 C-VB-3. PG100 Elastoflex SA P, Polyfresko G SBS SA Self-Adhering INSTA STIK, 12-inch o.c. -75.0 C-VB-4. PG100 Polyflex or Polybond Torch-applied P-LRFM, M-PG-1, OB500 or P-LRF-CR, 12-inch o.c. -135.0 C-VB-5. PG100 Elastoflex SA P, Polyfresko G SBS SA Self-Adhering P-LRFM, 12-inch o.c. -157.5 C-VB-6. PG100 Polyflex or Polybond Torch-applied P-LRFM, M-PG-1, OB500 or P-LRF-CR, 6-inch o.c. -185.0 C-VB-7. PG100 Elastoflex SA P, Polyfresko G SBS SA Self-Adhering P-LRF-CR, 12-inch o.c. -270.0 C-VB-8. PG100 Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self-Adhering P-LRFM, M-PG-1, OB500 or P-LRF-CR, 12-inch o.c. -240.0 C-VB-9. PG100 SBS-TA (with sanded-top-surface) Torch-applied P-LRFM, M-PG-1, OB500 or P-LRF-CR, 12-inch o.c. -240.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 6 of 90 17 The following products are interchangeable within the scope of this PEER. ACCEPTABLE ALTERNATES SUB-CATEGORY BY LISTED PRODUCT HEREIN ALTERNATE FBC HVHZ Adhesives Polyglass USA Polyglass LRF M (henceforth ‘P-LRFM’) Millennium One Step Foamable Adhesive NOA 21-1018.06 Polyglass LRF M-PG (henceforth ‘P-LRFM-PG’) Millennium PG-1 Pump Grade Adhesive Roofing Insulation Polyglass USA Polytherm ACFoam II NOA 23-0207.02 Polytherm G ACFoam III Polytherm-H H-Shield NOA 19-0521.04 Polytherm CG H-Shield CG Polytherm HD H-Shield HD Georgia-Pacific Gypsum, LLC DensDeck Prime DensDeck StormX Prime Roof Board NOA 22-1223.04 Roofing Fastener Polyglass USA #12 Polygrip Dekfast DF-#12-PH3 NOA 22-0913.02 #14 Polygrip Dekfast DF-#14-PH3 #15 Polygrip Dekfast DF-#15-PH3 Polygrip Hex Plate Dekfast PLT-H-2-7/8 18 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. FBC (HVHZ) 1620 and Roofing Application Standard RAS 128 for determination of design wind loads (Note 9 and Note 10). NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 7 of 90 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-1. Min. 19/32- inch APA rated CDX plywood Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 #12 Polygrip with Polygrip Hex Plate or Trufast #12 DP with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-2. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt SBS-AA, SBS- TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-3. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -45.0* W-4. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 8 of 90 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-5. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -52.5 W-6. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-7. Min. 19/32- inch APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1- 5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm G, Polytherm H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -60.0 W-8. Min. 19/32- inch APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1- 5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm G, Polytherm H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-9. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap Fastener 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 9 of 90 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-10. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap Fastener 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-11. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) or Elastovent 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -67.5 W-12. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Polyglass G2 Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 W-13. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top) or Elastovent 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in five (5) equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 W-14. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 10 of 90 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-15. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) or Elastovent 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 INSTA STIK, OB500, P- LRF-CR or P- LRFM, atop fastener rows, 7-inch o.c. Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK, OB500, P- LRF-CR or P- LRFM BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0* SELF-ADHERING BASE PLY: W-16. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -45.0* W-17. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 W-18. Min. 19/32- inch APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1- 5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm G, Polytherm H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-19. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap Fastener 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 11 of 90 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-20. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 INSTA STIK, OB500, P- LRF-CR or P- LRFM, atop fastener rows, 7-inch o.c. (Optional) Additional layers of base insulation INSTA STIK, OB500, P- LRF-CR or P- LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-21. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at min. 2-inch lap and 18- inch o.c. at two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -45.0* W-22. Min. 15/32- inch (existing) or min. 19/32- inch (new) APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at min. 2-inch lap and 12- inch o.c. at two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -52.5 W-23. Min. 19/32- inch APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1- 5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch lap and 8- inch o.c. at three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm G, Polytherm H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -60.0 W-24. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) Simplex MAXX Cap Fastener 12-inch o.c. at min. 4-inch lap and 12- inch o.c. at two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, Polytherm-H, Polytherm CG, ENRGY- 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 12 of 90 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-25. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at min. 4-inch lap and 6- inch o.c. at four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 INSTA STIK, OB500, P- LRF-CR or P- LRFM, atop fastener rows, 7-inch o.c. (Optional) Additional layers of base insulation INSTA STIK, OB500, P- LRF-CR or P- LRFM SBS-SA- H (Optional) SBS-TA SBS-TA -60.0* TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-26. Min. 15/32- inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top) or Elastovent Note 2 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5-inch Polytherm, Polytherm-H, Polytherm CG, ENRGY-3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-27. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5-inch Polytherm, Polytherm-H, Polytherm CG, ENRGY-3 or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -60.0 W-28. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5-inch Polytherm, Polytherm-H, Polytherm CG, ENRGY-3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 13 of 90 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-29. Min. 15/32- inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P (sanded-top) or Elastovent Note 2 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5-inch Polytherm, Polytherm-H, Polytherm CG, ENRGY-3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 SELF-ADHERING BASE PLY: W-30. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5-inch Polytherm, Polytherm-H, Polytherm CG, ENRGY-3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-31. Min. 19/32- inch APA rated CDX plywood Elastobase V, Elastobase P (sanded-top) or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. at min. 4- inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows (Optional) Min. 1.5-inch Polytherm, Polytherm-H, Polytherm CG, ENRGY-3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 14 of 90 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-32. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-AA, SBS- TA, APP-TA (Optional) SBS- AA, SBS-TA, APP-TA SBS-AA, SBS- TA, APP-TA -45.0 W-33. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-AA, SBS- TA, APP-TA (Optional) SBS- AA, SBS-TA, APP-TA SBS-AA, SBS- TA, APP-TA -75.0 W-34. Min. 19/32-inch APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board #12 Polygrip with Polygrip Hex Plate 1 per 1.3 ft2 (Optional if using AA Ply) BP-AA, SBS- AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -82.5 SELF-ADHERING BASE PLY: W-35. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, Dekfast DF- #14-PH3 with PLT-R-3, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 W-36. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 W-37. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 15 of 90 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply W-38. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 W-39. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 1-inch Polytherm, Polytherm G, Polytherm-H or Polytherm CG Note 2 (#14 only) 1 per 1.6 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -52.5 W-40. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP- TA -60.0 W-41. Min. 19/32-inch APA rated plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, Multi-Max FA3 or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate 1 per 1.3 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -67.5* Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 180 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-42. Min. 19/32-inch APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, Multi-Max FA3 or Ultra-Max optionally primed with POLYBRITE 745 or WB3000Polytherm, Polytherm-H or ENRGY 3 #12 Polygrip with Polygrip Hex Plate, Dekfast DF- #12-PH3 with PLT-R-3, OMG #12 Roofgrip with OMG 3 in. Galvalume Plate (non-ribbed) or Accutrac Plate or Trufast #12 DP with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -67.5* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-43. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, Dekfast DF- #14-PH3 with PLT-R-3, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 16 of 90 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply W-44. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 W-45. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -60.0 W-46. Min. 19/32” APA rated plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, Multi-Max FA3 or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate* 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -67.5* Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 180 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-47. Min. 19/32-inch APA rated CDX plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, Multi-Max FA3 or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip with Polygrip Hex Plate, Dekfast DF- #12-PH3 with PLT-R-3, OMG #12 Roofgrip with OMG 3 in. Galvalume Plate (non-ribbed) or Accutrac Plate or Trufast #12 DP with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -67.5* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 17 of 90 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-48. Min. 19/32-inch APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with Accutrac Flat Bottom or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -52.5 W-49. Min. 19/32-inch APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -60.0 W-50. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-AA, SBS-TA, APP- TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-51. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-52. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent Note 2 10-inch o.c. in 4-inch lap and 10- inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -75.0 W-53. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Polybase V Note 2 10-inch o.c. in 4-inch lap and 10- inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP- TA APP-TA -75.0 W-54. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Loose-laid Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-AA, SBS-TA, APP- TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 18 of 90 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-55. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Loose-laid Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-56. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent Note 2 9-inch o.c. in 4-inch lap and 9- inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -90.0 W-57. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Polybase V Note 2 9-inch o.c. in 4-inch lap and 9- inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP- TA APP-TA -90.0 W-58. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA -90.0 W-59. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA, APP-TA SBS-AA, SBS- TA or APP-TA -90.0 W-60. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Polybase V OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP- TA APP-TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 19 of 90 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-61. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Loose-laid Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-AA, SBS-TA, APP- TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-62. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Loose-laid Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-63. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in five (5), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA -120.0 W-64. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in five (5), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA, APP-TA SBS-AA, SBS- TA or APP-TA -120.0 W-65. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Polybase V OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in five (5), equally spaced, staggered center rows (Optional) APP- TA APP-TA -120.0 SELF-ADHERING BASE PLY: W-66. Min. 19/32-inch APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P (poly-film top) #14 Polygrip with Polygrip Hex Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -52.5* W-67. Min. 19/32-inch APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P (poly-film top) OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 20 of 90 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-68. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase V, Elastobase P (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-69. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase P (poly-film top) Note 2 (#14 only) 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at three (3), equally spaced center rows SBS-SA or SBS-TA SBS-SA, APP- SA, SBS-TA or APP-TA -127.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-70. Min. 19/32-inch APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P (poly-film top) #14 Polygrip with Polygrip Hex Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -52.5* W-71. Min. 19/32-inch APA rated CDX plywood One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P (poly-film top) OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0* W-72. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase V, Elastobase P (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 21 of 90 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply NO BASE PLY: W-73. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -45.0* W-74. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -52.5 W-75. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V (sanded top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -60.0 W-76. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V (poly-film top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None SBS-TA, APP-TA -60.0 W-77. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None APP-TA -60.0 W-78. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V (poly-film top) Simplex MAXX Cap Note: MAXX Caps are to be primed with PG100 or ASTM D41 primer 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None SBS-SA, APP-SA -60.0 W-79. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P, Elastovent,Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -60.0 W-80. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA, APP-SA -60.0 W-81. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -67.5 W-82. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows None APP-TA -67.5 W-83. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -75.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 22 of 90 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply W-84. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA -75.0 W-85. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 W-86. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None APP-TA -90.0 W-87. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 W-88. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA, APP-SA -97.5 W-89. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -105.0 W-90. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -112.5 W-91. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with PG100 or ASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA, APP-SA -112.5 ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-92. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -45.0* W-93. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -52.5 W-94. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V (sanded top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-95. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V (poly-film top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-TA SBS-TA, APP-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 23 of 90 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply W-96. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows APP-TA APP-TA -60.0 W-97. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -60.0 W-98. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -67.5 W-99. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows APP-TA APP-TA -67.5 W-100. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -75.0 W-101. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -75.0 W-102. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-103. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows APP-TA APP-TA -90.0 W-104. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-105. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -105.0 W-106. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -112.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 24 of 90 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply SELF-ADHERING BASE PLY: W-107. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood PolyAnchor, loose-laid with 4- inch laps followed by Elastoflex SA V, self-adhered 32 ga., 1-5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at min. 4-inch lap and 9-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA SBS-SA -45.0* W-108. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood PolyAnchor, loose-laid with 4- inch laps followed by Elastoflex SA V, self-adhered Simplex MAXX Cap 9-inch o.c. at min. 4-inch lap and 18-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA -45.0* W-109. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V (poly-film top) Simplex MAXX Cap Note: MAXX Caps are to be primed with PG100 or ASTM D41 primer 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-110. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood PolyAnchor, loose-laid with 4- inch laps followed by Elastoflex SA V, self-adhered Simplex MAXX Cap 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 W-111. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-112. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 12 ga. annular ring shank nails 7-inch o.c. at min. 4-inch lap and 7-inch o.c. at four (4), equally spaced center rows SBS-SA or SBS-TA SBS-SA, APP-SA, SBS-TA or APP-TA -75.0 W-113. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -97.5 W-114. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with PG100 or ASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Elastoflex SA V Plus, Elastoflex SA V Plus FR SBS-SA, APP-SA, SBS-TA, APP-TA -112.5 W-115. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood PolyAnchor, loose-laid with 4- inch laps followed by Elastoflex SA V, self-adhered Simplex MAXX Cap 6x6-inch grid SBS-SA SBS-SA -142.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-116. Min. 15/32” APA rated plywood Elastobase V (poly-film top) Simplex MAXX Cap Note: MAXX Caps are to be primed with PG100 or ASTM D41 primer 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0 W-117. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0 W-118. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. at min. 4-inch lap and 4-inch o.c. at four (4), equally spaced, staggered center rows SBS-SA-H SBS-TA -97.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 25 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap NO BASE PLY: W-119. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with Accutrac Flat Bottom or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -52.5 W-120. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -60.0 W-121. Min. 19/32-inch APA rated plywood Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-122. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None SBS-SA, APP-SA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-123. Min. 19/32-inch APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-124. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent Note 2 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -75.0 W-125. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Note 2 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA -75.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 26 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-126. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-127. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-128. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent Note 2 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 W-129. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Note 2 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None APP-TA -90.0 W-130. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA -90.0 W-131. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA or APP-TA -90.0 W-132. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 27 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-133. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-134. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows None APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-135. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows None SBS-AA -120.0 W-136. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows None SBS-AA, SBS-TA or APP-TA -120.0 W-137. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows None APP-TA -120.0 ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-138. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with Accutrac Flat Bottom or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -52.5 W-139. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P or Elastovent OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 28 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-140. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-141. Min. 19/32-inch APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-142. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent Note 2 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -75.0 W-143. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Note 2 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -75.0 W-144. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-145. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-146. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polyglass G2 Base, Elastobase V, Elastobase P or Elastovent Note 2 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 29 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-147. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V Note 2 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows APP-TA APP-TA -90.0 W-148. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -90.0 W-149. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty (min. 1-5/8-inch long) with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-150. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -90.0 W-151. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase V, Elastobase P or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-152. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-153. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -120.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 30 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-154. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Elastobase V, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -120.0 W-155. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated CDX plywood Polybase V OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plate or OMG Flat Bottom Metal Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows APP-TA APP-TA -120.0 W-156. Min. 19/32-inch APA rated plywood Elastobase V (sanded top) or Elastovent Trufast Versa Fastener (min. ¾” penetration) & Plate; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-157. Min. 19/32-inch APA rated plywood Elastobase V (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows SBS-TA SBS-TA, APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-158. Min. 19/32-inch APA rated plywood Polybase V Trufast Versa Fastener (min. ¾” penetration) & Plate; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows APP-TA APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance SELF-ADHERING BASE PLY: W-159. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood PolyAnchor, loose-laid with 4-inch laps followed by Elastoflex SA V, self- adhered OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Galvalume Steel Plate (non-ribbed) 9-inch o.c. at min. 4-inch lap and 18-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA -45.0* W-160. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) #14 Polygrip with Polygrip Hex Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5* W-161. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0* W-162. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood PolyAnchor, loose-laid with 4-inch laps followed by Elastoflex SA V, self- adhered OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Galvalume Steel Plate (non-ribbed) 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 31 of 90 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-163. Min. 19/32-inch APA rated plywood Elastobase V, Elastobase P (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-164. Min. 19/32-inch APA rated CDX plywood Elastobase V (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 1 screws per plate in center hole* Note: Versa-Fast Plate shall be primed with PG100 or ASTM D41 primer. 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-165. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood PolyAnchor, loose-laid with 4-inch laps followed by Elastoflex SA V, self- adhered OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Galvalume Steel Plate (non-ribbed) 8x8-inch grid pattern SBS-SA SBS-SA -127.5 W-166. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase P (poly-film top) Note 2 (#14 only) 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at three (3), equally spaced center rows SBS-SA or SBS-TA SBS-SA, APP-SA, SBS-TA or APP- TA -127.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-167. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) #14 Polygrip with Polygrip Hex Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -52.5* W-168. Min. 19/32-inch APA rated CDX plywood Elastobase V, Elastobase P (poly-film top) OMG #12 Roofgrip with OMG Accutrac Flat Bottom 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0* W-169. Min. 19/32-inch APA rated plywood Elastobase V, Elastobase P (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-170. Min. 19/32-inch APA rated CDX plywood Elastobase V (poly-film top) Trufast Versa Fastener (min. ¾” penetration) & Plate; 1 screws per plate in center hole* Note: Versa-Fast Plate shall be primed with PG100 or ASTM D41 primer. 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows SBS-SA-H SBS-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fastener within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 32 of 90 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-1. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* SC-2. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 4.0 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* SC-3. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 #14 Polygrip with Polygrip Hex Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -90.0 SC-4. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 #14 Polygrip with Polygrip Hex Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS- AA (Top surface primed with PG100 primer) SBS-SA, SBS-TA or APP-TA SBS-SA, APP-SA, SBS-TA or APP-TA -90.0 SC-5. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 SC-6. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 33 of 90 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-7. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM or P-LRFM-PG SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 SC-8. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G, Polytherm-H or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRFM SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-9. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRFM-PG SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-10. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 34 of 90 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-11. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G, Polytherm-H or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-12. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 SC-13. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-14. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm G or Polytherm-H Dekfast DF-#14-PH3 with PLT-R-3 or OMG #14 Roofgrip with OMG 3 in. Galvalume Steel Plate 1 per 1.0 ft2 Additional optional layer(s) base insulation followed by min. 0.25-inch DensDeck Prime P-LRF-CR SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 SELF-ADHERING BASE PLY: SC-15. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board PRIMER: POLYBRITE 745 or WB3000 INSTA STIK SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 35 of 90 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-16. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard or min. 1-inch Polytherm G or Polytherm CG INSTA STIK SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 SC-17. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board PRIMER: POLYBRITE 745 or WB3000 P-LRFM or P-LRFM-PG SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-18. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G, Polytherm-H or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard or min. 1-inch Polytherm G or Polytherm CG P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 SC-19. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard or min. 1-inch Polytherm G or Polytherm CG P-LRFM-PG SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 36 of 90 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-20. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board PRIMER: POLYBRITE 745 or WB3000 OB500 SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-21. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G, Polytherm-H or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard or min. 1-inch Polytherm G or Polytherm CG OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 SC-22. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board PRIMER: POLYBRITE 745 or WB3000 P-LRF-CR SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-23. Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch Polytherm G or Polytherm CG #12 Polygrip or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14- PH3 with Dekfast PLT-R-3, OMG #12 Roofgrip (steel only), #14 Roofgrip or #15 Roofgrip with OMG 3 in. Ribbed Galvalume Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Plate or Trufast #12 DP (steel only), Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate or Trufast 3” Recessed Metal Plate 1 per 2.0 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard or min. 1-inch Polytherm G or Polytherm CG P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 SC-24. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm G or Polytherm-H Dekfast DF-#14-PH3 with PLT-R-3 or OMG #14 Roofgrip with OMG 3 in. Galvalume Steel Plate 1 per 1.0 ft2 Additional optional layer(s) base insulation followed by min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -97.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 37 of 90 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-25. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm G or Polytherm-H Dekfast DF-#14-PH3 with PLT-R-3 or OMG #14 Roofgrip with OMG 3 in. Galvalume Steel Plate 1 per 1.0 ft2 Additional optional layer(s) base insulation followed by min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -97.5 COLD-APPLIED BASE PLY: SC-26. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-27. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM or P-LRFM-PG SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-28. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-29. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3 or Multi-Max FA3 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 38 of 90 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-30. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.75-inch JM Fesco Board (homogeneous) or min. 1.5-inch JM Fesco Board (laminated) #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Ribbed Galvalume Plate or AccuTrac Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-31. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Ribbed Galvalume Plate or AccuTrac Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 4.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-32. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Ribbed Galvalume Plate or AccuTrac Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 4.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-33. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch H-Shield WF #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Ribbed Galvalume Plate or AccuTrac Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 4.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-34. Min. 22 ga., type B, Grade 40 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, min. 1.5” thick, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board #12 Polygrip, #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3, DF-#14-PH-3 or DF-#15-PH3 with PLT-R-3, OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip with OMG 3 in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Plate or Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -52.5 SC-35. Min. 22 ga., type B, Grade 40 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, min. 1.5” thick, loose laid Min. 0.25-inch DensDeck Prime #12 Polygrip, #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3, DF-#14-PH-3 or DF-#15-PH3 with PLT-R-3, OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip with OMG 3 in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Plate or Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 39 of 90 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-36. Min. 22 ga., type B, Grade 40 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, min. 1.5” thick, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board #12 Polygrip, #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3, DF-#14-PH-3 or DF-#15-PH3 with PLT-R-3, OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip with OMG 3 in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Plate or Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -67.5 SC-37. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate 1 per 1.8 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -75.0 SC-38. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -82.5 SELF-ADHERING BASE PLY: SC-39. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm or Polytherm-H #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG AccuTrac Flat Bottom Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -45.0* SC-40. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0* SC-41. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP-SA, SBS-TA or APP- TA -45.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 40 of 90 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-42. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#14-PH3 with PLT-R-3, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 SC-43. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fastener with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 SC-44. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA or APP- TA -45.0 SC-45. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA or APP- TA -45.0 SC-46. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch, loose laid Min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#14-PH3 with Dekfast PLT-R-3, OMG #14 Roofgrip with OMG 3” Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 SBS-SA (Optional) SBS- SA SBS-SA, APP-SA -45.0 SC-47. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board #15 Polygrip with Polygrip Hex Plate, Dekfast DF-#15-PH3 with Dekfast PLT-R-3, OMG #15 Roofgrip with OMG 3” Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or OMG Accutrac Flat Bottom Plate or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 SBS-SA (Optional) SBS- SA SBS-SA, APP-SA -45.0 SC-48. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm or Polytherm-H #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 SC-49. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -60.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 41 of 90 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-50. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, Multi-Max FA3 or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14-PH3 with PLT-R-3, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Accutrac Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5* SC-51. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -72.5 SC-52. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate 1 per 1.8 ft2 SBS-SA (Optional) SBS- TA SBS-TA -75.0 SC-53. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -90.0 SC-54. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -97.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: SC-55. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm or Polytherm-H H #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG AccuTrac Flat Bottom Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0* SC-56. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#14-PH3 with PLT-R-3, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 42 of 90 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-57. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 SC-58. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm or Polytherm-H optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -60.0 SC-59. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -60.0 SC-60. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, Multi-Max FA3 or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, Dekfast DF-#12-PH3 (steel only) or DF-#14-PH3 with PLT-R-3, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Accutrac Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -67.5* SC-61. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #12 Polygrip (steel only) or #14 Polygrip with Polygrip Hex Plate, OMG #12 Roofgrip (steel only) or OMG #14 Heavy Duty with OMG 3 in. Galvalume Plate (non-ribbed) or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -72.5 SC-62. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OMG #14 Heavy Duty with OMG 3 in. Galvalume Steel Plate 1 per 1.8 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -75.0 SC-63. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 43 of 90 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-64. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 #14 Polygrip or #15 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast #15 EHD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -97.5 COLD-APPLIED BASE PLY: SC-65. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG 3 in. Ribbed Galvalume Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0* TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-66. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P, Elastovent or JM Perma-Ply 28 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 18-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -45.0* SC-67. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -52.5 SC-68. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V, Elastobase P or Elastovent Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plate (square) 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -60.0 SC-69. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Polybond, Polyflex #14 Polygrip with Polygrip Hex Plate or OMG #14 Roofgrip with OMG Flat Bottom Plate 12-inch o.c. at the 4-inch lap and 18-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -112.5 SELF-ADHERING BASE PLY: NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 44 of 90 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SC-70. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V or Elastobase P with poly top surface #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -52.5* SC-71. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V or Elastobase P with poly top surface Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plate (square) 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: SC-72. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V or Elastobase P with poly top surface #14 Polygrip with Polygrip Hex Plate, OMG #14 Roofgrip with OMG Flat Bottom Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -52.5* SC-73. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase V or Elastobase P with poly top surface Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plate (square) 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0* COLD-APPLIED BASE PLY: SC-74. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastobase V Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at one staggered center row (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -45.0* SC-75. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastovent Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at one staggered center row (Optional) SBS-CA1 SBS-CA1, APP- CA1 -45.0* SC-76. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastobase V Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -67.5 SC-77. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastovent Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) SBS-CA1 SBS-CA1, APP- CA1 -67.5 SC-78. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose- laid Elastoflex S6 Trufast #12 DP (steel only) or Trufast #14 HD (steel or concrete) with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at one staggered center row (Optional) Elastoflex S6 applied in PG350 at 1.5-2.0 gal/square SBS-CA1 -75.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 45 of 90 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SC-79. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose- laid Elastoflex S6 Trufast #12 DP (steel only) or Trufast #14 HD (steel or concrete) with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) Elastoflex S6 applied in PG350 at 1.5-2.0 gal/square SBS-CA1 -90.0* TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCIFLEX, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT- OR TORCH-APPLIED: SC-80. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate or Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA -45.0 SC-81. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA -60.0 SC-82. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 18-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -60.0 SC-83. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -82.5 SC-84. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP Trufast #14 HD with Trufast 2.4” Barbed Metal Seam Plate 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -82.5 SC-85. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoshield VP HT #15 Polygrip with Dekfast PLT-O2-3/4-12B or Dekfast PLT-R-2-3/8-6B or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plate, Trufast 2.4” Scoop Seam Plate or Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -82.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 46 of 90 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCIFLEX, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SC-86. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination Prelim. Attached Polyflex #15 Polygrip with Dekfast PLT-R-2-3/8-6B 12-inch o.c. within the 5-inch wide, torch-sealed side lap (Optional) APP-TA SBS-TA, APP- TA -82.5 SC-87. Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Polybond or Polyflex Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4 in. Barbed Seam Plate 12-inch o.c. within the 6-inch wide, torch-sealed side lap (Optional) APP-TA SBS-TA, APP- TA -82.5 SC-88. Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoshield VP HT #15 Polygrip with Dekfast PLT-O2-3/4-12B or Dekfast PLT-R-2-3/8-6B or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plate, Trufast 2.4” Scoop Seam Plate or Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -97.5 SC-89. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -135.0 SELF-ADHERING: SC-90. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP (poly-film top) OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 18-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-SA SBS-SA -45.0 SC-91. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Loose- laid Elastoflex S6 HP (poly-film top) OMG Super XHD Fastener with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 18-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-SA SBS-SA -52.5 SC-92. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP (poly-film top) OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-SA SBS-SA -75.0 SC-93. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP (poly-film top) OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-SA SBS-SA -90.0 COLD-APPLIED: NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 47 of 90 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCIFLEX, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 3, Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SC-94. Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 18-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) Elastoflex S6 applied in PG350 at 1.5- 2.0 gal/square SBS-CA1 -60.0 Note: When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped-in with minimum 6-inch wide strips of torch-applied, sand-top-surfaced, Polyglass SBS modified bitumen membrane prior to placement of subsequent Base Ply or Cap Ply membranes in PG350 adhesive. SC-95. Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP OMG Super XHD Fastener (steel only) with OMG 2 3/4 Super XHD Barbed Stress Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2-3/4” Barbed Metal Seam Plate (EHD) 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) Elastoflex S6 applied in PG350 at 1.5- 2.0 gal/square SBS-CA1 -82.5 Note: When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped-in with minimum 6-inch wide strips of torch-applied, sand-top-surfaced, Polyglass SBS modified bitumen membrane prior to placement of subsequent Base Ply or Cap Ply membranes in PG350 adhesive. NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 48 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: C-1 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H or Polytherm CG INSTA STIK Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 C-2 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG INSTA STIK Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -202.5 C-3 Structural concrete None Min. 2-inch Polytherm or Polytherm- H INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-4 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch Dens Deck Prime INSTA STIK SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-5 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board INSTA STIK SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-6 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H or Polytherm CG OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 C-7 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi- Max FA3 OB500 0.5-inch SECUROCK Cement Roof Board OB500 SBS-TA (Optional) SBS-TA SBS-TA -187.5 C-8 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -202.5 C-9 Structural concrete None Min. 2-inch Polytherm or Polytherm- H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-10 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi- Max FA3 OB500, 6- inch o.c. 0.5-inch SECUROCK Cement Roof Board OB500, 6- inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-11 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-12 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board OB500 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 49 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-13 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H or Polytherm CG P-LRFM or P-LRFM-PG Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRFM or P-LRFM-PG SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 C-14 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi- Max FA3 P-LRFM or P-LRFM-PG 0.5-inch SECUROCK Cement Roof Board P-LRFM or P-LRFM-PG SBS-TA (Optional) SBS-TA SBS-TA -187.5 C-15 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG P-LRFM or P-LRFM-PG Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRFM or P-LRFM-PG SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -202.5 C-16 Structural concrete None Min. 2-inch Polytherm or Polytherm- H P-LRFM or P-LRFM-PG Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM or P-LRFM-PG BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-17 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi- Max FA3 P-LRFM or P-LRFM-PG, 6-inch o.c. 0.5-inch SECUROCK Cement Roof Board P-LRFM or P-LRFM-PG, 6-inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-18 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch Dens Deck Prime P-LRFM or P-LRFM-PG SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-19 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board P-LRFM or P-LRFM-PG SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-20 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H or Polytherm CG P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -187.5 C-21 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi- Max FA3 P-LRF-CR 0.5-inch SECUROCK Cement Roof Board P-LRF-CR SBS-TA (Optional) SBS-TA SBS-TA -187.5 C-22 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-AA, SBS- TA or APP-TA (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -202.5 C-23 Structural concrete None Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi- Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 50 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-24 Structural concrete None Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi- Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR APP-TA (Optional) APP-TA APP-TA -232.5 C-25 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi- Max FA3 P-LRF-CR, 6-inch o.c. 0.5-inch SECUROCK Cement Roof Board P-LRF-CR, 6- inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-26 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-27 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board P-LRF-CR SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-28 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-29 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -232.5 C-30 Structural concrete PG100 Min. 0.75-inch Fesco Board (homogeneous) Hot asphalt None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -277.5 C-31 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -290.0 C-32 Structural concrete PG100 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -285.0 C-33 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -480.0 C-34 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -480.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 51 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-35 Structural concrete PG100 Min. 0.25-inch Dens Deck Prime Hot asphalt None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -510.0 SELF-ADHERING BASE PLY TO INSULATION: C-36 Structural concrete (Optional) PG100 Min. 1.5-inch Polytherm-H or Multi- Max FA3 INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 C-37 Structural concrete None Min. 1.5-inch Polytherm-H INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-38 Structural concrete (Optional) PG100 Min. 1.5-inch Polytherm or ENRGY 3 INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -135.0 C-39 Structural concrete None Min. 1-inch Polytherm or Polytherm- H INSTA STIK Min 1.5-inch Polytherm G or Polytherm CG INSTA STIK SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-40 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG INSTA STIK (Optional) additional layers of base insulation INSTA STIK SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-41 Structural concrete None Min. 1.5-inch, Insulfoam IX OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0 C-42 Structural concrete None Min. 1.5-inch Polytherm OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-43 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 C-44 Structural concrete None Min. 1.5-inch Polytherm-H OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -150.0 C-45 Structural concrete None Min. 1-inch Polytherm or Polytherm- H OB500 Min 1.5-inch Polytherm G or Polytherm CG OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-46 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-47 Structural concrete None Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR OB500 None N/A SBS-SA (Optional) SBS-SA SBS-SA -230.0 C-48 Structural concrete None Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR OB500, 6- inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -285.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 52 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-49 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG (Optional) additional layers(s) of base insulation P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-50 Structural concrete None Min. 1-inch Polytherm or Polytherm- H P-LRFM or P-LRFM-PG Min 1.5-inch Polytherm G or Polytherm CG P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-51 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG P-LRFM or P-LRFM-PG (Optional) additional layers of base insulation P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-52 Structural concrete None Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRFM or P-LRFM-PG None N/A SBS-SA (Optional) SBS-SA SBS-SA -230.0 C-53 Structural concrete None Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM (Optional) additional layers(s) of base insulation P-LRFM SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -232.5 C-54 Structural concrete None Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRFM or P-LRFM-PG, 6-inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -285.0 C-55 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or UltraMax P-LRFM or P-LRFM-PG (Optional) additional layers(s) of base insulation, optionally primed with POLYBRITE 745 or WB3000 P-LRFM or P-LRFM-PG SBS-SA None SBS-CA1, SBS- CA2 -290.0 C-56 Structural concrete None Min. 1.5-inch Polytherm, Polytherm-H P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-57 Structural concrete None Min. 1-inch Polytherm or Polytherm- H P-LRF-CR Min 1.5-inch Polytherm G or Polytherm CG P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-58 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG P-LRF-CR (Optional) additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-59 Structural concrete None Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR None N/A SBS-SA (Optional) SBS-SA SBS-SA -230.0 C-60 Structural concrete None Min. 1.5-inch, Insulfoam IX P-LRF-CR (Optional) additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0 C-61 Structural concrete None Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6-inch o.c. None N/A SBS-SA (Optional) SBS-SA SBS-SA -285.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 53 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-62 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt (Optional) additional layers(s) of base insulation Hot asphalt SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -480.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY TO INSULATION: C-63 Structural concrete (Optional) PG100 Min. 1.5-inch Polytherm-H or Multi- Max FA3 INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 C-64 Structural concrete None Min. 1.5-inch Polytherm-H INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-65 Structural concrete (Optional) PG100 Min. 1.5-inch Polytherm or ENRGY 3 INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -135.0 C-66 Structural concrete None Min. 1.5-inch Polytherm OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-67 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 C-68 Structural concrete None Min. 1.5-inch Polytherm-H OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -150.0 C-69 Structural concrete None Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG (Optional) additional layers(s) of base insulation P-LRFM or P-LRFM-PG SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-70 Structural concrete None Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM (Optional) additional layers(s) of base insulation P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -232.5 C-71 Structural concrete None Min. 1.5-inch Polytherm, Polytherm-H P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-72 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt (Optional) additional layers(s) of base insulation Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -480.0 SELF-ADHERING BASE PLY TO COVERBOARD: C-73 Structural concrete None Min. 1.5-inch Multi-Max FA3 INSTA STIK Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 C-74 Structural concrete None Min. 1.5-inch Insulfoam IX INSTA STIK Min. 0.25-inch Dens Deck Prime INSTA STIK SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-75 Structural concrete None Min. 1.5-inch, Insulfoam IX INSTA STIK Min. 0.25-inch Dens Deck, Dens Deck Prime INSTA STIK SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -120.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 54 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-76 Structural concrete None Min. 1-inch Polytherm or Polytherm- H INSTA STIK Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard INSTA STIK SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-77 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG INSTA STIK Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard INSTA STIK SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-78 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 INSTA STIK SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-79 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch DEXcell FA Glass Mat Roof Board INSTA STIK SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-80 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 INSTA STIK SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-81 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -127.5 C-82 Structural concrete None Min. 1.5-inch Polytherm or Polytherm-H OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -150.0 C-83 Structural concrete None Min. 1-inch Polytherm or Polytherm- H OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-84 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-85 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX OB500 Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR OB500 SBS-SA (Optional) SBS-SA SBS-SA -230.0 C-86 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 55 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-87 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -285.0 C-88 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch DEXcell FA Glass Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-89 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OB500 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-90 Structural concrete None Min. 1-inch Polytherm or Polytherm- H P-LRFM or P-LRFM-PG Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-91 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG P-LRFM or P-LRFM-PG Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-92 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX P-LRFM or P-LRFM-PG Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA SBS-SA -230.0 C-93 Structural concrete None Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -232.5 C-94 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch Dens Deck Prime P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-95 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRFM or P-LRFM-PG, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -285.0 C-96 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch DEXcell FA Glass Mat Roof Board P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-97 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 56 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-98 Structural concrete None Min. 1.5-inch Insulfoam IX P-LRF-CR Min. 0.25-inch Dens Deck or Dens Deck Prime P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-99 Structural concrete None Min. 1-inch Polytherm or Polytherm- H P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -187.5 C-100 Structural concrete None Min. 1.5-inch Polytherm G or Polytherm CG P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Polytherm HD or ACFoam-HD Coverboard P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-101 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA -230.0 C-102 Structural concrete None Min. 1.5-inch, Insulfoam IX, Min. 1.0- inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi-Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch Dens Deck, Dens Deck Prime P-LRF-CR SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -240.0 C-103 Structural concrete None Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi- Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 C-104 Structural concrete None Min. 1.5-inch Insulfoam IX P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -240.0 C-105 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-106 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -285.0 C-107 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch or DEXcell FA Glass Mat Roof Board P-LRF-CR SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 57 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-108 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 P-LRF-CR SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-109 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -350.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY TO COVERBOARD: C-110 Structural concrete None Min. 1.5-inch Multi-Max FA3 INSTA STIK Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 C-111 Structural concrete None Min. 1.5-inch, Insulfoam IX INSTA STIK Min. 0.25-inch Dens Deck, Dens Deck Prime INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -120.0 C-112 Structural concrete None Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-113 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-114 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 or DEXcell FA Glass Mat Roof Board INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 C-115 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 C-116 Structural concrete None Min. 1.5-inch Polytherm or Polytherm-H OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -150.0 C-117 Structural concrete None Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-118 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-119 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 58 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-120 Structural concrete None Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -232.5 C-121 Structural concrete None Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 P-LRFM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-122 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch Dens Deck Prime P-LRFM or P-LRFM-PG SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-123 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRFM or P-LRFM-PG Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board P-LRFM or P-LRFM-PG SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 C-124 Structural concrete None Min. 1.5-inch, Insulfoam IX, Min. 1.0- inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi-Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch Dens Deck, Dens Deck Prime P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 C-125 Structural concrete None Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi- Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 C-126 Structural concrete None Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-127 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-128 Structural concrete None (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 C-129 Structural concrete PG100 Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -350.0 COLD-APPLIED BASE PLY: C-130 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H or ENRGY 3 INSTA STIK Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 59 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-131 Structural concrete None Min. 1-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board INSTA STIK SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-132 Structural concrete None Min. 1-inch Polytherm, Polytherm G or Polytherm-H INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-133 Structural concrete None Min. 1-inch Polytherm-H or ENRGY 3 INSTA STIK Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 C-134 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM or P-LRFM-PG SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-135 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5- inch SECUROCK Cement Roof Board P-LRFM, P- LRFM-PG SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-136 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM, P- LRFM-PG SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-137 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM, P- LRFM-PG SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 60 of 90 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-138 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-139 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board OB500 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-140 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-141 Structural concrete None Min. 1-inch Polytherm, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 C-142 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-143 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board P-LRF-CR SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-144 Structural concrete None Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-145 Structural concrete None Min. 1-inch ENRGY 3, Polytherm-H, Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 61 of 90 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) *MDP (psf) Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: C-146 Structural concrete PG100 (Optional) SBS-TA (Optional) SBS-TA SBS-TA -495.0 C-147 Structural concrete PG100 BP-AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -622.5 SELF-ADHERING BASE PLY: C-148 Structural concrete PG100 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -202.5 C-149 Structural concrete PG100 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -315.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: C-150 Structural concrete PG100 SBS-SA-H (Optional) SBS-TA SBS-TA -315.0 COLD-APPLIED BASE PLY: C-151 Structural concrete None SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -105.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 62 of 90 TABLE 4A: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (NOA 18-0717.05): ASPHALT OR TORCH APPLIED BASE PLY: LWC-1 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -282.5 LWC-2 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -367.5 LWC-3 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DEXcell FA Glass Mat Roof Board OB500 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -322.5 LWC-4 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -225.0 LWC-5 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -322.5 LWC-6 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR BP-AA, SBS- AA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -222.5 LWC-7 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 7/16-inch DEXcell Cement Roof Board P-LRF-CR BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -222.5 SELF-ADHERING BASE PLY: NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 63 of 90 TABLE 4A: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-8 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA or APP-SA -72.5 LWC-9 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -282.5 LWC-10 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DEXcell FA Glass Mat Roof Board OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -322.5 LWC-11 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or WB3000 OB500 SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -322.5 LWC-12 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- SA SBS-SA or APP-SA -72.5 LWC-13 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch, Insulfoam IX P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -222.5 LWC-14 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 LWC-15 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -222.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 64 of 90 TABLE 4A: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-16 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, optionally primed with WB3000 P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 LWC-17 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 7/16-inch DEXcell Cement Roof Board, optionally primed with WB3000 P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -222.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-18 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -282.5 LWC-19 Structural concrete Min. 390 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX OB500 Min. 0.25-inch DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -322.5 LWC-20 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 LWC-21 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 ELASTIZELL (NOA 23-0817.05): ASPHALT OR TORCH APPLIED BASE PLY: LWC-22 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -225.0 LWC-23 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -180.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 65 of 90 TABLE 4A: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-24 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 7/16-inch DEXcell Cement Roof Board P-LRF-CR BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 SELF-ADHERING BASE PLY: LWC-25 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, Insulfoam IX OB500 (Optional) Additional layers of base insulation OB500 SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -120.0 LWC-26 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, optionally primed with WB3000 OB500 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -120.0 LWC-27 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, Polytherm- H or ENRGY 3 OB500 (Optional) Additional layers of base insulation OB500 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -225.0 LWC-28 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, optionally primed with WB3000 OB500 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -225.0 LWC-29 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- SA SBS-SA or APP-SA -72.5 LWC-30 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, Insulfoam IX P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -180.0 LWC-31 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -180.0 LWC-32 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -180.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 66 of 90 TABLE 4A: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-33 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, optionally primed with WB3000 P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -180.0 LWC-34 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 7/16-inch DEXcell Cement Roof Board, optionally primed with WB3000 P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -180.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-35 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -120.0 LWC-36 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, Polytherm- H or ENRGY 3 OB500 (Optional) Additional layers of base insulation OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -225.0 LWC-37 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -225.0 LWC-38 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA-H (Optional) SBS- TA SBS-TA -180.0 LWC-39 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS- TA SBS-TA -180.0 MEARLCRETE (NOA 19-0729.03): ASPHALT OR TORCH APPLIED BASE PLY: LWC-40 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR BP-AA, SBS- AA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -222.5 LWC-41 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 7/16-inch DEXcell Cement Roof Board P-LRF-CR BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -222.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 67 of 90 TABLE 4A: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING BASE PLY: LWC-42 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- SA SBS-SA or APP-SA -72.5 LWC-43 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch, Insulfoam IX P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -222.5 LWC-44 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 LWC-45 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -222.5 LWC-46 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, optionally primed with WB3000 P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 LWC-47 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi- Max FA3 or Insulfoam IX P-LRF-CR Min. 7/16-inch DEXcell Cement Roof Board, optionally primed with WB3000 P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -222.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-48 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) Additional layers of base insulation P-LRF-CR SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 LWC-49 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3, Multi-Max FA3 or Insulfoam IX P-LRF-CR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 PRE-EXISTENT CELULAR LWC (NOTE 14): ASPHALT OR TORCH APPLIED BASE PLY: LWC-50 Structural concrete Min. 280 psi, min. 2-inch thick pre-existent cellular lightweight concrete. (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H, Polytherm CG Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-AA (Optional) SBS- AA SBS-AA -235.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 68 of 90 TABLE 4B: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Temp Roof Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-51 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. at min. 4-inch lap and 7-inch o.c. at two, equally spaced center rows (Optional) SBS-TA (sanded- top- surface) (Optional) Min. 1.5- inch Polytherm, Polytherm- H, Multi- Max FA3 or Polytherm HA Min. 1.5-inch Thermaroof Composite, Polytherm Composite, or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) HA (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0 LWC-52 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Elastobase V, Elastobase P or Elastovent Trufast FM-90 Base Sheet Fastener 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. at three equally spaced, staggered center rows SBS-TA (sanded- top- surface) Min. 2-inch Polytherm, Polytherm G, Polytherm- H, Polytherm CG, ENRGY 3 or Multi- Max FA3 P-LRFM, 6- inch o.c. Additional Insulation Layer(s): (Optional) Min. 0.5-inch base insulation flat or tapered Coverboard: Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Additional Layer(s): P- LRFM, 4-inch o.c. Coverboard: P-LRFM, 6- inch o.c. BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0* LWC-53 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. at min. 4-inch lap and 7-inch o.c. at two, equally spaced center rows (Optional) SBS-TA (sanded- top- surface) Min. 1.5- inch Polytherm, Polytherm- H, Multi- Max FA3 or Polytherm HA None N/A SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 69 of 90 TABLE 4B: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Temp Roof Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-54 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Elastobase V, Elastobase P or Elastovent Trufast FM-90 Base Sheet Fastener 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. at three equally spaced, staggered center rows SBS-TA (sanded- top- surface) Min. 2-inch Polytherm, Polytherm G, Polytherm- H, Polytherm CG, ENRGY 3 or Multi- Max FA3 P-LRFM, 6- inch o.c. (Optional) Additional layers of base insulation, min. 0.5- inch, flat or tapered P-LRFM, 4- inch o.c. SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -60.0* LWC-55 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. at min. 4-inch lap and 7-inch o.c. at two, equally spaced center rows (Optional) SBS-TA (sanded- top- surface) Min. 1.5- inch Polytherm, Polytherm- H, Multi- Max FA3 or Polytherm HA None N/A SBS-SA-H (Optional) SBS-TA SBS-TA -45.0 LWC-56 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Elastobase V, Elastobase P or Elastovent Trufast FM-90 Base Sheet Fastener 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. at three equally spaced, staggered center rows SBS-TA (sanded- top- surface) Min. 2-inch Polytherm, Polytherm G, Polytherm- H, Polytherm CG, ENRGY 3 or Multi- Max FA3 P-LRFM, 6- inch o.c. (Optional) Additional layers of base insulation, min. 0.5- inch, flat or tapered P-LRFM, 4- inch o.c. SBS-SA-H (Optional) SBS-TA SBS-TA -60.0* ‡ NOTE: For steel deck application where specific deck attachment is not referenced, tested attachment was 5/8” puddle welds with weld-washers or #12 HWH Teks 5 screws spaced 6” o.c. NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 70 of 90 TABLE 4C: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply PRE-EXISTENT CELLULAR LIGHTWEIGHT INSULATING CONCRETE: LWC-57 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick pre-existent cellular LWC. Note: To qualify the LWIC, an OMG C-R Assembled Base Sheet Fastener (1.7 in.) shall achieve an average withdrawal of 53 lbf when tested per Note 11. B3 or B11 OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet (Optional) BP-AA, SBS- AA SBS-AA, APP- TA -45.0 CELCORE (NOA 18-0717.05): ASPHALT OR TORCH APPLIED BASE PLY: LWC-58 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Celcore B1 through B11 Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-59 Min. 26 ga., type HF steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, B7, B8, B10 or B11 OMG C-R Assembled Base Sheet Fastener (1.7 in.) 9-inch o.c. in a 3-inch lap and 9-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-60 Min. 22 ga., type B steel at max 6 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, B7, B8, B10 or B11 OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 14-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-61 Min. 22 ga., type B steel at max 6 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, B7, B8, B10 or B11 OMG C-R Assembled Base Sheet Fastener (1.7 in.) 9-inch o.c. in a 3-inch lap and 9-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-62 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2 or B11 Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0 LWC-63 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 or B11 Trufast FM-90 Base Sheet Fastener 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -60.0 LWC-64 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows SBS-TA or APP-TA SBS-TA or APP-TA -60.0 LWC-65 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore B1 through B11 Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS- TA or APP-TA -75.0 SELF-ADHERING BASE PLY: NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 71 of 90 TABLE 4C: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-66 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 LWC-67 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-68 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture B2 (with poly- film top surface) Trufast Twin Loc-Nail 9-inch o.c. at a min. 4-inch lap and 18- inch o.c. at two, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -45.0 LWC-69 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener 8-inch o.c. at a min. 4-inch lap and 8- inch o.c. at three equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0 ELASTIZELL (NOA 23-0817.05): ASPHALT OR TORCH APPLIED BASE PLY: LWC-70 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B1 through B11 Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0 LWC-71 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-TA or APP-TA SBS-TA or APP-TA -45.0 LWC-72 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 or B11 Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet BP-AA or SBS-AA SBS-AA, SBS- TA, SBS-SA, APP-TA or APP-SA -60.0 LWC-73 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SELF-ADHERING BASE PLY: LWC-74 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 72 of 90 TABLE 4C: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-75 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-76 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Range II Elastizell Lightweight Insulating Concrete B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. at a min. 3-inch lap and 7- inch o.c. at two, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -45.0 LWC-77 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. at a min. 4-inch lap and 6- inch o.c. at three, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -60.0 MEARLCRETE (NOA 19-0729.03): ASPHALT OR TORCH APPLIED BASE PLY: LWC-78 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B1, B2, B3, B7 or B11 Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 LWC-79 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SELF-ADHERING BASE PLY: LWC-80 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -52.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-81 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 Base Sheet Fastener or OMG C-R Assembled Base Sheet Fastener (1.7 in.) 7-inch o.c. at a min. 4-inch lap and 7- inch o.c. at two, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -52.5 ‡ NOTE: For steel deck application where specific deck attachment is not referenced, tested attachment was 5/8” puddle welds with weld-washers or #12 HWH Teks 5 screws spaced 6” o.c. See Note 1. A. Base Sheets options in Table 4C are coded as follows: B1: Polyglass G2 Base; B2: Elastobase V or Elastobase P; B3: GAFGLAS #75; B4: GAFGLAS Stratavent Nailable Venting Base Sheet; B5: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6; B7: JM Perma Ply No. 28; B8: JM Vensulation; B9: JM GlasPly IV; B10: JM GlasPly Premier; B11: Elastovent NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 73 of 90 TABLE 4D: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED VAPOR BARRIER, LWC, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Vapor Barrier Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Fasten (Note 11) Attach Base Ply Cap Ply CELCORE (NOA 18-0717.05): TORCH APPLIED BASE PLY: LWC-82 Min. 22 ga., Type B, Grade 40 steel; 5 ft span; 5/8-inch puddle welds, 6” o.c. Min. 0.625- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 Elastoflex S6 G or Polyflex G, torch-applied Min. 350 psi, min. 2- inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Elastobase V, Elastobase P, Elastovent, Polybase V or Polyglass G2 Base OMG C-R Assembled Base Sheet Fastener (1.7 in.), OlyLock 1.8, Trufast FM- 90 Base Sheet Fastener or Trufast Twin Loc-Nails (1.8 in.) 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. at two, equally spaced center rows (Optional) APP-TA or SBS-TA APP-TA or SBS-TA -52.5 LWC-83 Min. 22 ga., Type B, Grade 40 steel; 5 ft span; 5/8-inch puddle welds, 6” o.c. Min. 0.625- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 Elastoflex S6 G or Polyflex G, torch-applied Min. 350 psi, min. 2- inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Elastobase V, Elastobase P, Elastovent, Polybase V or Polyglass G2 Base Trufast Versa-Fast Fasteners and Versa-Fast Plates; two (2) screws per plate 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. at two, equally spaced center rows (Optional) APP-TA or SBS-TA APP-TA or SBS-TA -60.0 TABLE 4E: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP (psf) Type Treatment Base Ply Ply Cap Ply CELCORE (NOA 18-0717.05): LWC-84 Min. 22 ga., Type B, Grade 33 steel, 6 ft span; #12 HWH Teks 5, 6” o.c. Min. 200 psi, min. 2-inch Celcore Cellular Concrete or min. 350 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) SBS- SA, APP-TA or SBS-TA APP-SA, SBS- SA, APP-TA or SBS-TA -60.0 LWC-85 Min. 22 ga., Type BV, Grade 40 steel, 6 ft span; 5/8” puddle welds, 6” o.c. Celcore S-1 Deck Preparation Min. 350 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) SBS- SA, APP-TA or SBS-TA APP-SA, SBS- SA, APP-TA or SBS-TA -67.5 LWC-86 Min. 22 ga., Type B, Grade 33 steel, 5 ft span; #12 HWH Teks 5, 6” o.c. Min. 200 psi, min. 2-inch Celcore Cellular Concrete Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) SBS- SA, APP-TA or SBS-TA APP-SA, SBS- SA, APP-TA or SBS-TA -75.0 LWC-87 Min. 22 ga., Type BV, Grade 40 steel, 6 ft span; 5/8” puddle welds, 6” o.c. Celcore S-1 Deck Preparation Min. 310 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) SBS- SA, APP-TA or SBS-TA APP-SA, SBS- SA, APP-TA or SBS-TA -82.5 LWC-88 Min. 22 ga., Type B, Grade 33 steel, 4 ft span; #12 HWH Teks 5, 6” o.c. Min. 200 psi, min. 2-inch Celcore Cellular Concrete Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) SBS- SA, APP-TA or SBS-TA APP-SA, SBS- SA, APP-TA or SBS-TA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 74 of 90 TABLE 4E: DECK WITH LIGHTWEIGHT CONCRETE – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP (psf) Type Treatment Base Ply Ply Cap Ply LWC-89 Structural concrete Min. 225 psi, min. 2-inch Celcore MF Cellular Concrete Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) SBS- SA APP-SA or SBS-SA -210.0 LWC-90 Structural concrete Min. 225 psi, min. 2-inch Celcore MF Cellular Concrete Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) APP- TA or SBS-TA APP-TA or SBS-TA -262.5 LWC-91 Structural concrete Min. 400 psi, min. 2-inch Celcore Cellular Concrete (no EPS) or min. 350 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Modifleece applied in Polyglass LRF CR, spatter-applied (Optional) APP- TA or SBS-TA APP-TA or SBS-TA -277.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 75 of 90 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: CWF-1 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 INSTA STIK or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation INSTA STIK or OB500 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -45.0 CWF-2 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 INSTA STIK or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board INSTA STIK or OB500 SBS-TA or APP- TA (Optional) SBS- TA or APP-TA SBS-TA, APP- TA -45.0 CWF-3 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 P-LRF-CR Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation P-LRF-CR BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -52.5 CWF-4 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 P-LRF-CR Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-TA or APP- TA (Optional) SBS- TA or APP-TA SBS-TA, APP- TA -52.5 CWF-5 Tectum Plank, max. 4 ft span; Trufast #12 Purlin Fastener & Trufast 2” Barbed Metal Seam Plate, three (3) equally spaced for 3 ft panel width (12” o.c.) (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -75.0 CWF-6 Tectum Plank, max. 4 ft span; Trufast #12 Purlin Fastener & Trufast 2” Barbed Metal Seam Plate, three (3) equally spaced for 3 ft panel width (12” o.c.) (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-TA or APP- TA (Optional) SBS- TA or APP-TA SBS-TA, APP- TA -75.0 SELF-ADHERING BASE PLY: CWF-7 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 INSTA STIK or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board INSTA STIK or OB500 SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -45.0 CWF-8 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 P-LRF-CR Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -52.5 CWF-9 Tectum Plank, max. 4 ft span; Trufast #12 Purlin Fastener & Trufast 2” Barbed Metal Seam Plate, three (3) equally spaced for 3 ft panel width (12” o.c.) (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP- TA -75.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 76 of 90 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: CWF-10 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 INSTA STIK or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board INSTA STIK or OB500 SBS-SA- H (Optional) SBS- TA SBS-TA -45.0 CWF-11 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ISO 95+GL, Polytherm-H, ENRGY- 3 P-LRF-CR Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA- H (Optional) SBS- TA SBS-TA -52.5 CWF-12 Tectum Plank, max. 4 ft span; Trufast #12 Purlin Fastener & Trufast 2” Barbed Metal Seam Plate, three (3) equally spaced for 3 ft panel width (12” o.c.) (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-SA- H (Optional) SBS- TA SBS-TA -75.0 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-13 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 2-inch Polytherm or Polytherm-H H OMG Polymer GypTec with Polymer GypTec Plate or Trufast TL with Trufast TL 3 in. Plate 1 per 4.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 77 of 90 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: CWF-14 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase V, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board, Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS- AA, SBS-TA, APP-TA -45.0* CWF-15 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase V, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA or APP- TA (Optional) SBS-TA, SBS-SA or APP-TA SBS-TA, SBS-SA, APP- TA, APP-SA -45.0* SELF-ADHERING BASE PLY: CWF-16 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase V, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-TA, SBS-SA or APP-TA SBS-TA, SBS-SA, APP- TA, APP-SA -45.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: CWF-17 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase V, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. at min. 4-inch lap and 18- inch o.c. at two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -45.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 78 of 90 TABLE 5D: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply CWF-18 Existing Min. 2.5- inch Tectum Plank or Tectum LS Plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc- Nails (min. 1-inch embedment) 1 per 2.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* TABLE 5E: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply CWF-19 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase V, Elastobase P, Polyglass G2 Base Trufast Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -45.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 79 of 90 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: G-1 Existing gypsum deck Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -245.0 G-2 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H or Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRF-CR 0.5-inch SECUROCK Cement Roof Board P-LRF-CR SBS-TA (Optional) SBS-TA SBS-TA -187.5 G-3 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H or Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR BP-AA, SBS- AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 G-4 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H or Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRF-CR, 6-inch o.c. 0.5-inch SECUROCK Cement Roof Board P-LRF-CR, 6-inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -232.5 G-5 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H or Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRF-CR Min. 0.25-inch DensDeck Prime P-LRF-CR SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -282.5 G-6 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G or Polytherm-H or Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -322.5 SELF-ADHERING BASE PLY: G-7 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 or min. Insulfoam IX OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -72.5 G-8 Existing gypsum deck Min. 1.5-inch min. Insulfoam IX OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP- SA -112.5 G-9 Existing gypsum deck Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -112.5 G-10 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 or min. Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -112.5 G-11 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch Dens Deck Prime P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -72.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 80 of 90 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-12 Existing gypsum deck Min. 1.5-inch Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRFM (Optional) additional layers(s) of base insulation P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -202.5 G-13 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -202.5 G-14 Existing gypsum deck (Optional) Min. 1.5-inch, Insulfoam IX, Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -72.5 G-15 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA -230.0 G-16 Existing gypsum deck Min. 1.5-inch, Insulfoam IX P-LRF-CR (Optional) additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA -240.0 G-17 Existing gypsum deck Min. 1.5-inch, Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -240.0 G-18 Existing gypsum deck Min. 1.5-inch Insulfoam IX P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -240.0 G-19 Existing gypsum deck Min. 1.5-inch Polytherm, Polytherm G, Polytherm- H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) additional layers of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -257.5 G-20 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -257.5 G-21 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -285.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: G-22 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 or min. Insulfoam IX OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 G-23 Existing gypsum deck Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -112.5 G-24 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 or min. Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -112.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 81 of 90 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-25 Existing gypsum deck Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch Dens Deck Prime P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 G-26 Existing gypsum deck Min. 1.5-inch Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRFM (Optional) additional layers(s) of base insulation P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -202.5 G-27 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -202.5 G-28 Existing gypsum deck (Optional) Min. 1.5-inch, min. 2.0 pcf EPS insulation board, Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 G-29 Existing gypsum deck Min. 1.5-inch, Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 G-30 Existing gypsum deck Min. 1.5-inch Polytherm, Polytherm G, Polytherm- H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -257.5 G-31 Existing gypsum deck (Optional) Min. 1.5-inch Polytherm, Polytherm G, Polytherm-H, Polytherm CG, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -257.5 COLD APPLIED BASE PLY: G-32 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2- inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -120.0 G-33 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2- inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 G-34 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2- inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRFM SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 82 of 90 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-35 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra-Max or min. 2- inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2 -202.5 G-36 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -112.5 G-37 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -120.0 G-38 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board P-LRF-CR SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 G-39 Existing gypsum deck (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 G-40 Existing gypsum deck (Optional) Min. 1-inch ENRGY 3, Polytherm-H, Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2 -232.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 83 of 90 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE B-3: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-41 Existing gypsum deck Elastobase V, Elastobase P, Elastovent or Polyglass G2 Base Trufast FM-75 or FM-90 or Twin Loc-Nails 9-inch o.c. in 4- inch lap and 18- inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, Polytherm G, Polytherm- H, ENRGY 3 or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board, Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 3, Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply G-42 Existing gypsum deck (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc- Nails (min. 1-inch embedment) 1 per 2.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply G-43 Existing gypsum deck Elastobase V, Elastobase P, Elastovent or Polyglass G2 Base Trufast FM-75 or FM-90 or Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 84 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: R-1 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Multi-Max FA3 INSTA STIK Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 R-2 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm or ENRGY 3 or Insulfoam IX INSTA STIK Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board INSTA STIK BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, or APP-TA -90.0 R-3 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, or APP-TA -127.5 R-4 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -157.5 R-5 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi-Max FA3 or Ultra-Max or Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR BP-AA, SBS- AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 R-6 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi-Max FA3 or Ultra-Max or Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR APP-TA (Optional) APP-TA APP-TA -232.5 SELF-ADHERING BASE PLY: R-7 Existing, fully-adhered, asphaltic roof (Optional if Top Layer Insulation installed) Min. 1.5-inch Multi-Max FA3 INSTA STIK (Optional if Base Layer Insulation installed) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck Prime INSTA STIK SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 R-8 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3 or Multi-Max FA3 or Insulfoam IX INSTA STIK Min. 0.25-inch Dens Deck Prime INSTA STIK SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-9 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Insulfoam IX INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA (Optional) SBS-SA SBS-SA -90.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 85 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-10 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Insulfoam IX INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -90.0 R-11 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Polytherm or ENRGY 3 INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -90.0 R-12 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm or ENRGY 3 INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -90.0 R-13 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 or Insulfoam IX OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-14 Existing, fully-adhered, asphaltic roof Min. 1.5-inch, Insulfoam IX OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-15 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch, Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -120.0 R-16 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 R-17 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 R-18 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX OB500 Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR OB500 SBS-SA (Optional) SBS-SA SBS-SA -127.5 R-19 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch Dens Deck Prime P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-20 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRFM (Optional) additional layers(s) of base insulation P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -157.5 R-21 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -157.5 R-22 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX P-LRFM or P-LRFM-PG Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRFM or P-LRFM-PG SBS-SA (Optional) SBS-SA SBS-SA -157.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 86 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-23 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G, min. 1.5-inch Insulfoam X, Multi- Max FA3 or Ultra-Max or min. 2.0- inch Polytherm P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-24 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H or Insulfoam IX P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA -230.0 R-25 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Insulfoam IX P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA SBS-SA -240.0 R-26 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 R-27 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Multi-Max FA3 or Ultra-Max, min. 1.3-inch Polytherm G or min. 1.0-inch Polytherm H, Polytherm CG or ENRGY 3 P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 R-28 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi-Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 R-29 Existing, fully-adhered, asphaltic roof Min. 1.5-inch, Insulfoam IX IX P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -240.0 R-30 Existing, fully-adhered, asphaltic roof Min. 2-inch Polytherm, ENRGY-3, Polytherm-H P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -247.5 R-31 Existing, fully-adhered, asphaltic roof (Optional) Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -247.5 R-32 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm G or Polytherm-H P-LRF-CR Polytherm HD, ACFoam-HD Coverboard or ACFoam-HD Coverboard-FR P-LRF-CR, 6-inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -262.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 87 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-33 Existing, fully-adhered, asphaltic roof (Optional if Top Layer Insulation installed) Min. 1.5-inch Multi-Max FA3 INSTA STIK (Optional if Base Layer Insulation installed) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck Prime INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 R-34 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3 or Multi-Max FA3 or Insulfoam IX INSTA STIK Min. 0.25-inch Dens Deck Prime INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-35 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Insulfoam IX INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 R-36 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Polytherm or ENRGY 3 INSTA STIK (Optional) additional layers(s) of base insulation INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 R-37 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm or ENRGY 3 INSTA STIK Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 R-38 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 or Insulfoam IX OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-39 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch, Insulfoam IX OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -120.0 R-40 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 R-41 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, Polytherm-H or ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 R-42 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch Dens Deck Prime P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-43 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRFM (Optional) additional layers(s) of base insulation P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -157.5 R-44 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Polytherm, ENRGY 3, Polytherm-H or Multi-Max FA3 P-LRFM Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM SBS-SA-H (Optional) SBS-TA SBS-TA -157.5 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 88 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-45 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G, min. 1.5-inch Insulfoam X, Multi- Max FA3 or Ultra-Max or min. 2.0- inch Polytherm P-LRF-CR Min. 0.25-inch Dens Deck Prime P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-46 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.5-inch Insulfoam IX P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 R-47 Existing, fully-adhered, asphaltic roof Min. 1.5-inch Multi-Max FA3 or Ultra-Max, min. 1.3-inch Polytherm G or min. 1.0-inch Polytherm H, Polytherm CG or ENRGY 3 P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 R-48 Existing, fully-adhered, asphaltic roof (Optional) Min. 1.0-inch Polytherm-H, Polytherm CG or ENRGY 3, min. 1.3-inch Polytherm G or min. 1.5-inch Multi-Max FA3 or Ultra-Max P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 R-49 Existing, fully-adhered, asphaltic roof Min. 2-inch Polytherm, ENRGY-3, Polytherm-H P-LRF-CR (Optional) additional layers(s) of base insulation P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 R-50 Existing, fully-adhered, asphaltic roof (Optional) Min. 2-inch Polytherm, Polytherm-H or ENRGY 3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 COLD APPLIED BASE PLY: R-51 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H or ENRGY 3 INSTA STIK Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board INSTA STIK SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -90.0 R-52 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra- Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM or P-LRFM-PG SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 89 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-53 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra- Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM, P- LRFM-PG SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-54 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra- Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRFM, P- LRFM-PG SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-55 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, EnergyGuard Polyiso Insulation, ENRGY 3, Multi-Max FA3 or Ultra- Max or min. 2-inch Styrofoam Brand Roofmate, Highload 60 or Plazamate P-LRFM, P- LRFM-PG Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board P-LRFM, P- LRFM-PG SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2 -157.5 R-56 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 R-57 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board OB500 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-58 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-59 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 NEMO|etc.® ©NEMO ETC, LLC P.E. EVALUATION REPORT: 8TH EDITION (2023) FBC HVHZ PEER-PLYG-001.B.R17 for FL1654-R33 (HVHZ) Certificate of Authorization #32455 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 17: 10/04/2023 TOP OF APPENDIX Appendix 1, Page 90 of 90 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new insulation and roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf)A Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-60 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board P-LRF-CR SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-61 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch Polytherm, Polytherm G, Polytherm-H, ENRGY 3 or Multi-Max FA3 P-LRF-CR Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-62 Existing, fully-adhered, asphaltic roof (Optional) Min. 1-inch ENRGY 3, Polytherm-H, Multi-Max FA3 P-LRF-CR Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board P-LRF-CR SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2 -232.5 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER A The reported MDP documents the allowable maximum design pressure of the new roof cover when installed atop the substrate, irrespective of the deck type (See Note 1) or performance of the substrate (See Note 12). The deck and substrate shall be capable of resisting the project design pressure requirements, not to exceed the noted MDP, to the satisfaction of the Authority Having Jurisdiction. System No. Substrate (Note 1, Note 12) Primer Roof Cover (Note 15) MDP (psf)A Base Ply Ply Cap Ply R-63 Existing fully-adhered, granule- surfaced modified bitumen None (Optional) Polyflex, torch-applied (Optional) Polyflex, torch-applied APP-TA -362.5 R-64 Existing fully-adhered, granule- surfaced modified bitumen PG100 (Optional) Polyflex, torch-applied (Optional) Polyflex, torch-applied APP-TA -445.0