No preview available
 /
     
2217 ALICIA LN RES24-0103 MASHOD ARCH DWGSENTRY BATH 1 BEDROOM 1 CLO.1 UTILITY BREAKFAST LIVING DINING KITCHEN CLO. FAMILY ROOM UP 4'-712"1'-11"11'-712"15'-278"13'-712"17'-558" 19'-414"11'-958"15'-6"13'-658"5'-614"8'-178"5'-718"6'-1178" 5'-878"4'-312"6'-1018"5'-818" 13'-1118"11'-558"8'-438"10'-612"9'-0"15'-314" FRONT PORCH DN HVAC WINDOW TO BE REMOVED AND REPLACED. WIDTH TO REMAIN THE SAME. REMOVE EXISTING COLUMNS. REPLACE DOOR UNIT. WIDTH TO REMAIN THE SAME. REMOVE WALL & WING WALLS REMOVE WALL & WING WALLS REMOVE WALL & WING WALLS REMOVE WALL & WING WALLS REMOVE CLOSET & ADD ELEVATOR SHAFT. 2ND FLOOR AS-BUILT PLAN SCALE: 3/8 " = 1'-0" 1 ID 0.0 2ND FLOORAS BUILT PLANAS INDICATED DRAWN_BY ID0.0 RIVER & PALM INTERIORS A RESIDENTIAL REMODEL FORMASHOD2217 ALICIA LANEATLANTIC BEACH, FL 32233ISSUE SCALE: SHEET NO.: DRAWN BY: 05-07-24 PERMIT SET C:\USERS\RIVER\ONEDRIVE\RIVER & PALM INTERIORS, LLC\CURRENT CLIENTS\MASHOD\DRAWINGS\CAD DRAWINGS\PERMIT SET\X-REF MASHOD BASEPLANS- AS BUILTS.DWG PUBLISHED:5/7/2024 11:53 AMDO NOT MEASURE NOTIFY DESIGNER OF ANY & ALL DISCREPANCIES PRIOR TO CONSTRUCTION; SEE GENERAL NOTES PRIMARY BATH PRIMARY BED OFFICE PRIMARY CLO. BEDROOM 2 BATH 2 CLO. 2 DN LANDING9'-312"15'-912" 17'-712"14'-6"11'-1112"10'-712" 18'-4" 5'-5"5'-012"8'-412"5'-5" 10'-0"13'-9"8'-10"6'-412"8'-512"18'-3"10'-9"STAIR WINDOW TO BE REMOVED AND REPLACED. WIDTH TO REMAIN THE SAME. REMOVE EXISTING COLUMNS. REPLACE DOOR UNIT. WIDTH TO REMAIN THE SAME. REMOVE CLOSET & ADD ELEVATOR SHAFT. SCALE: X INCH = X FEET 3RD FLOOR AS BUILT PLAN SCALE: 3/8 " = 1'-0" 1 ID 0.0 3RD FLOORAS BUILT PLANAS INDICATED DRAWN_BY ID0.1 RIVER & PALM INTERIORS A RESIDENTIAL REMODEL FORMASHOD2217 ALICIA LANEATLANTIC BEACH, FL 32233ISSUE SCALE: SHEET NO.: DRAWN BY: 05-07-24 PERMIT SET C:\USERS\RIVER\ONEDRIVE\RIVER & PALM INTERIORS, LLC\CURRENT CLIENTS\MASHOD\DRAWINGS\CAD DRAWINGS\PERMIT SET\X-REF MASHOD BASEPLANS- AS BUILTS.DWG PUBLISHED:5/7/2024 11:53 AMDO NOT MEASURE NOTIFY DESIGNER OF ANY & ALL DISCREPANCIES PRIOR TO CONSTRUCTION; SEE GENERAL NOTES CLEAR INSIDE DEPTH 3414"CLEAR INSIDE5WIDTHGATE OPEN2912"42" USABLE INSIDE 9.98 SQ.FT.EMI LOCKENTRY BATH 1 BEDROOM 1 CLO.1 UTILITY COAT/FISHING KITCHEN LIVING DININGPANTRY BUILT-IN STACKED WASHER/ DRYER DISHWASHER REF 36" INDUCTION & DOWNDRAFT 5'-2"4'-1012" TRASH 33" SINK 21'-638"15'-278"14'-478"18'-418" 19'-414"11'-758"13'-9"8'-118"5'-178"8'-412"5'-614"8'-0"19'-638"6'-1178" 5'-878"4'-312"6'-1018"5'-818" 13'-1118"11'-558"UP8'-438"10'-612" FREEZER OVENS OVENS U.C.BEV HVAC PORCH DN STAIR GENERAL NOTES: 1.ALL WORK TO BE DONE IN ACCORDANCE TO THE MOST RECENT EDITION OF FLORIDA BUILDING CODES AND ALL OTHER APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES. 2.VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN FIELD PRIOR TO CONSTRUCTION. VERIFY LAYOUT WITH REFERENCE TO EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE COMMUNICATED IN WRITING TO THE ARCHITECT BEFORE CONSTRUCTION PROCEEDS. 3.IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL WORK IS IN STRICT ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE CONSTRUCTION STANDARDS. 4.ALL DIMENSIONS ARE TO FACE OF DRYWALL OR CENTERLINE OF STRUCTURE UNLESS OTHERWISE NOTED. 5.FLOOR PENETRATIONS TO BE WATERPROOFED. 6.ALL INTERIOR WALLS TO BE WOOD STUDS UNLESS OTHERWISE NOTED. 7.WHERE G.C. IS TO PROVIDE TYPE 'X' GYP. BD. FOR A RATED ASSEMBLY, THE TYPE 'X' GYP. BD. IS REQUIRED TO GO BENEATH THE SHEATHING AND FINISHES. 8.INTERIOR DOORS ARE TO BE 5" OFF PERPENDICULAR WALLS UNLESS OTHERWISE NOTED. 9.IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL MANUFACTURED ARTICLES, MATERIAL AND EQUIPMENT ARE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, ADJUSTED, OPERATED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS, UNLESS HEREIN SPECIFIED TO THE CONTRARY. BUILDER SHALL FOLLOW ALL INSTRUCTIONS TO SUSTAIN AND PRESERVE ALL EXPRESSED OR IMPLIED WARRANTIES AND GUARANTEES. 10.IT IS THE BUILDER'S RESPONSIBILITY TO CHECK ALL PLAN DIMENSIONS & DETAILS FOR OVERALL ACCURACY APPROPRIATE TO THE SITE & FINAL SELECTION OF MASONRY, FLOOR JOISTS, LUMBER, STRUCTURAL MEMBERS, VENEER, ROOFING, ETC. 11.SUBSTITUTES FOR SPECIFIC MATERIALS & MANUFACTURERS SHOWN ON THESE PLANS MAY BE OFFERED, BUT MUST BE APPROVED IN WRITING BY THE ARCHITECT AND OWNER PRIOR TO PROCURING OR INSTALLING. 12.RESPONSIBILITY OF THE GC INCLUDES, BUT IS NOT LIMITED TO, PROPER INSTALLATION OF MATERIALS, NAILING, GLUING, CAULKING, INSULATING, FLASHING, ROOFING, WEATHERPROOFING & ANY OTHER SMALL ITEMS OR DETAILS NOT NECESSARILY INDICATED ON THE PLANS. 13.THESE PLANS ARE NOT INTENDED TO BE COMPLETE IN ALL DETAILS OF WEATHERPROOFING. USE OF A VARIETY OF DIFFERENT MATERIALS CAN CHANGE DETAILS. ADDITIONALLY, VARYING CODES & REGULATIONS, FOUNDATION REQUIREMENTS, ELECTRICAL AND MECHANICAL PLANS CAN CHANGE THESE DETAILS. 14.FURNITURE TO BE COORDINATED, INSTALLED AND SCHEDULED BY G.C. AND THE OWNER 15.ALL KITCHEN APPLIANCES INSTALLED TO BE COORDINATED AND SCHEDULED BY G.C. 16.G.C. TO SCHEDULE & COORDINATE THE INSTALLATION OF OWNER PROVIDED ITEMS, INCLUDING, BUT NOT LIMITED TO, FURNITURE & AUDIO/VIDEO SYSTEMS. BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: JACKSONVILLE BEACH BUILDING CODE: Florida Building Code 8th Edition (2023) Building Florida Building Code 8th Edition (2023) Residential Florida Building Code 8th Edition (2023) Plumbing National Electric Code 2020 - NFPA 70-2019 Florida Building Code 8th Edition (2023) Energy Conservation Florida Building Code 8th Edition (2023) Mechanical Florida Fire Prevention Code 8th Edition ALTERATION LEVEL: 2 OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-3) CONSTRUCTION TYPE: TYPE V-B (WOOD FRAME) SPRINKLED: NO FIRE DISTRICT: NO WORK AREA: EXISTING A/C AREA: 1750 S.F. 2ND FLOOR PROPOSED PLAN SCALE: 3/8 " = 1'-0" 1 ID 0.0 2ND FLOORPROPOSED PLANAS INDICATED DRAWN_BY ID1.0 RIVER & PALM INTERIORS A RESIDENTIAL REMODEL FORMASHOD2217 ALICIA LANEATLANTIC BEACH, FL 32233ISSUE SCALE: SHEET NO.: DRAWN BY: 04-23-24 PERMIT SET C:\USERS\RIVER\ONEDRIVE\RIVER & PALM INTERIORS, LLC\CURRENT CLIENTS\MASHOD\DRAWINGS\CAD DRAWINGS\MASHOD 2ND FLOOR ELEVATIONS.DWG PUBLISHED: 5/7/2024 1:05PMDO NOT MEASURE NOTIFY DESIGNER OF ANY & ALL DISCREPANCIES PRIOR TO CONSTRUCTION; SEE GENERAL NOTES CLEAR INSIDE DEPTH 3414"CLEAR INSIDE5WIDTHGATE OPEN2912"42" USABLEINSIDE 9.98 SQ.FT.EMI LOCKP-1 SC-1 RC-1RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 P-2 P-3 P-3 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-2 SC-2 RC-2 RC-1 RC-1 RC-1 RC-1 TV RC-1 GFCI STACKED WASHER/ DRYER DISHWASHER REF 36" INDUCTION & DOWNDRAFT FREEZER OVENS OVENS U.C.BEV 220V 220V ENTRY BATH 1 BEDROOM 1 CLO.1 UTILITY COAT/FISHING KITCHEN LIVING DINING PANTRY HVAC STAIRUP DN GFCI GFCI GFCI GFCI GFCI GFCI LED TAPE & PLUGMOLD LED TAPE & PLUGMOLD LED TAPE & PLUGMOLD LED TAPE LED TAPE LED TAPE LED TAPE TV FLOOR OUTLET s P-1 RC-2 RC-1 TV OUTLET FLOOR RECEPTACLE RECESSED CAN- DOWNLIGHT RECESSED CAN- ADJUSTABLE PENDANT LIGHT SURFACE MOUNT SCONCE EXHAUST FAN LED TAPE TV 220V 220V OUTLET ELECTRICAL LEGEND FLUORESCENT FIXTURE sc MAIN HOUSE CIRCUIT BREAKER PANELS LOCATED IN GARAGE NO CHANGES ON LOWER LEVELS 2ND FLOOR ELECTRICAL PLAN SCALE: 3/8 " = 1'-0" 1 ID 0.0 2ND FLOORELECTRICAL PLANAS INDICATED DRAWN_BY ID1.2 RIVER & PALM INTERIORS A RESIDENTIAL REMODEL FORMASHOD2217 ALICIA LANEATLANTIC BEACH, FL 32233ISSUE SCALE: SHEET NO.: DRAWN BY: 05-07-24 PERMIT SET C:\USERS\RIVER\ONEDRIVE\RIVER & PALM INTERIORS, LLC\CURRENT CLIENTS\MASHOD\DRAWINGS\CAD DRAWINGS\PERMIT SET\MASHOD 2ND FLOOR ELEVATIONS.DWG PUBLISHED:5/7/2024 3:19 PMDO NOT MEASURE NOTIFY DESIGNER OF ANY & ALL DISCREPANCIES PRIOR TO CONSTRUCTION; SEE GENERAL NOTES CLEAR INSIDE DEPTH 3414"CLEAR INSIDE5WIDTHGATE OPEN2912"42" USABLE INSIDE 9.98 SQ.FT.EMI LOCKPRIMARY BATH PRIMARY BED OFFICE PRIMARY CLO. BEDROOM 2 BATH 2 CLO. 2 TUB BENCH WC 14'-212"12'-3"5'-212"5'-11"3'-312"STEAM SHOWER 15'-0" 18'-812"14'-112"11'-1112"14'-212" 15'-0" 5'-5"5'-212"9'-1"5'-5" 10'-0"14'-9"9'-11"6'-0"5'-1112"4'-11" DN TOWER CABINET TOWER CABINET BOOKCASE BOOKCASE WOOD STAIR WOOD FLOOR WOOD FLOOR WOOD FLOOR WOOD FLOOR TILE FLOOR TILE FLOOR WOOD FLOOR WOOD FLOOR WOOD FLOOR LANDING OPEN TO BELOW GENERAL NOTES: 1.ALL WORK TO BE DONE IN ACCORDANCE TO THE MOST RECENT EDITION OF FLORIDA BUILDING CODES AND ALL OTHER APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES. 2.VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN FIELD PRIOR TO CONSTRUCTION. VERIFY LAYOUT WITH REFERENCE TO EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE COMMUNICATED IN WRITING TO THE ARCHITECT BEFORE CONSTRUCTION PROCEEDS. 3.IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL WORK IS IN STRICT ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE CONSTRUCTION STANDARDS. 4.ALL DIMENSIONS ARE TO FACE OF DRYWALL OR CENTERLINE OF STRUCTURE UNLESS OTHERWISE NOTED. 5.FLOOR PENETRATIONS TO BE WATERPROOFED. 6.ALL INTERIOR WALLS TO BE WOOD STUDS UNLESS OTHERWISE NOTED. 7.WHERE G.C. IS TO PROVIDE TYPE 'X' GYP. BD. FOR A RATED ASSEMBLY, THE TYPE 'X' GYP. BD. IS REQUIRED TO GO BENEATH THE SHEATHING AND FINISHES. 8.INTERIOR DOORS ARE TO BE 5" OFF PERPENDICULAR WALLS UNLESS OTHERWISE NOTED. 9.IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL MANUFACTURED ARTICLES, MATERIAL AND EQUIPMENT ARE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, ADJUSTED, OPERATED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS, UNLESS HEREIN SPECIFIED TO THE CONTRARY. BUILDER SHALL FOLLOW ALL INSTRUCTIONS TO SUSTAIN AND PRESERVE ALL EXPRESSED OR IMPLIED WARRANTIES AND GUARANTEES. 10.IT IS THE BUILDER'S RESPONSIBILITY TO CHECK ALL PLAN DIMENSIONS & DETAILS FOR OVERALL ACCURACY APPROPRIATE TO THE SITE & FINAL SELECTION OF MASONRY, FLOOR JOISTS, LUMBER, STRUCTURAL MEMBERS, VENEER, ROOFING, ETC. 11.SUBSTITUTES FOR SPECIFIC MATERIALS & MANUFACTURERS SHOWN ON THESE PLANS MAY BE OFFERED, BUT MUST BE APPROVED IN WRITING BY THE ARCHITECT AND OWNER PRIOR TO PROCURING OR INSTALLING. 12.RESPONSIBILITY OF THE GC INCLUDES, BUT IS NOT LIMITED TO, PROPER INSTALLATION OF MATERIALS, NAILING, GLUING, CAULKING, INSULATING, FLASHING, ROOFING, WEATHERPROOFING & ANY OTHER SMALL ITEMS OR DETAILS NOT NECESSARILY INDICATED ON THE PLANS. 13.THESE PLANS ARE NOT INTENDED TO BE COMPLETE IN ALL DETAILS OF WEATHERPROOFING. USE OF A VARIETY OF DIFFERENT MATERIALS CAN CHANGE DETAILS. ADDITIONALLY, VARYING CODES & REGULATIONS, FOUNDATION REQUIREMENTS, ELECTRICAL AND MECHANICAL PLANS CAN CHANGE THESE DETAILS. 14.FURNITURE TO BE COORDINATED, INSTALLED AND SCHEDULED BY G.C. AND THE OWNER 15.ALL KITCHEN APPLIANCES INSTALLED TO BE COORDINATED AND SCHEDULED BY G.C. 16.G.C. TO SCHEDULE & COORDINATE THE INSTALLATION OF OWNER PROVIDED ITEMS, INCLUDING, BUT NOT LIMITED TO, FURNITURE & AUDIO/VIDEO SYSTEMS. BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: JACKSONVILLE BEACH BUILDING CODE: Florida Building Code 8th Edition (2023) Building Florida Building Code 8th Edition (2023) Residential Florida Building Code 8th Edition (2023) Plumbing National Electric Code 2020 - NFPA 70-2019 Florida Building Code 8th Edition (2023) Energy Conservation Florida Building Code 8th Edition (2023) Mechanical Florida Fire Prevention Code 8th Edition ALTERATION LEVEL: 2 OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-3) CONSTRUCTION TYPE: TYPE V-B (WOOD FRAME) SPRINKLED: NO FIRE DISTRICT: NO WORK AREA: EXISTING A/C AREA: 1532 S.F. 3RD FLOOR PROPOSED PLAN SCALE: 3/8 " = 1'-0" 1 ID 0.0 3RD FLOORPROPOSED PLANAS INDICATED DRAWN_BY ID2.0 RIVER & PALM INTERIORS A RESIDENTIAL REMODEL FORMASHOD2217 ALICIA LANEATLANTIC BEACH, FL 32233ISSUE SCALE: SHEET NO.: DRAWN BY: 05-07-24 PERMIT SET C:\USERS\RIVER\ONEDRIVE\RIVER & PALM INTERIORS, LLC\CURRENT CLIENTS\MASHOD\DRAWINGS\CAD DRAWINGS\PERMIT SET\MASHOD 3RD FLOOR ELEVATIONS.DWG PUBLISHED:5/7/2024 3:24 PMDO NOT MEASURE NOTIFY DESIGNER OF ANY & ALL DISCREPANCIES PRIOR TO CONSTRUCTION; SEE GENERAL NOTES CLEAR INSIDE DEPTH 3414"CLEAR INSIDE5WIDTHGATE OPEN2912"42" USABLEINSIDE 9.98 SQ.FT.EMI LOCKPRIMARY BATH PRIMARY BED OFFICE PRIMARY CLO. BEDROOM 2 BATH 2 CLO. 2 LANDING STAIR RC-1RC-1 RC-1RC-1RC-1 RC-1 RC-2 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1RC-1 RC-1 RC-1 P-5 P-6 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 P-4 RC-1 RC-1 RC-1 RC-1 RC-1 RC-1 TV TV GFCI GFCI GFCI LED TAPE LED TAPE LED TAPE LED TAPE DN RC-1 RC-1 RC-1 s P-1 RC-2 RC-1 TV OUTLET FLOOR RECEPTACLE RECESSED CAN- DOWNLIGHT RECESSED CAN- ADJUSTABLE PENDANT LIGHT SURFACE MOUNT SCONCE EXHAUST FAN LED TAPE TV 220V 220V OUTLET ELECTRICAL LEGEND FLUORESCENT FIXTURE sc MAIN HOUSE CIRCUIT BREAKER PANELS LOCATED IN GARAGE NO CHANGES ON LOWER LEVELS 3RD FLOOR ELECTRICAL PLAN SCALE: 3/8 " = 1'-0" 1 ID 0.0 3RD FLOORELECTRICAL PLANAS INDICATED DRAWN_BY ID2.2 RIVER & PALM INTERIORS A RESIDENTIAL REMODEL FORMASHOD2217 ALICIA LANEATLANTIC BEACH, FL 32233ISSUE SCALE: SHEET NO.: DRAWN BY: 05-07-24 PERMIT SET C:\USERS\RIVER\ONEDRIVE\RIVER & PALM INTERIORS, LLC\CURRENT CLIENTS\MASHOD\DRAWINGS\CAD DRAWINGS\PERMIT SET\MASHOD 3RD FLOOR ELEVATIONS.DWG PUBLISHED:5/7/2024 3:24 PMDO NOT MEASURE NOTIFY DESIGNER OF ANY & ALL DISCREPANCIES PRIOR TO CONSTRUCTION; SEE GENERAL NOTES