469 ATLANTIC BLVD COMM24-0011 A101-FLOOR PLAN-2 REV 5-3-24GFI6" METAL STUD INTERIOR WALL 4" METAL STUD BEARING INTERIOR WALL 4" METAL STUD INTERIOR WALL EXISTING 8" CMU EXTERIOR WALL EXISTING BARBER SHOPEXISTING CHIROPRACTICGLASS DISPLAY CASE 36"H COUNTER42"H COUNTERPREP TABLE PASS THRU OPENING PASS THRU SERVING COUNTERHAND SINK 42"H COUNTER PASS THRU (OPEN) 1 2 3 4 5 BOH 209 SQ FT FOH 197 SQ FT (INCLUDES COUNTERS) REF HAND SINK ICE MACHINE FLOOR DRAIN F FIRE EXTINGUISER3 COMPARTMENT SINKPREP TABLE ELECTRIC SANDWICH PRESS REST ROOM 5' - 0"4"13' - 6"42' - 10"4"5' - 8"18' - 10" PREP TABLE ELECTRIC JUICE MAKE ELECTRIC BLENDER ELECTRIC COFFEE MACHINE EXPRESSO MACHINE 5' - 4"3' - 0"15' - 2"4"19' - 0"4"5' - 8"48' - 10"EXIST. W.H. GREASE TRAP BELOW EXISTING ELEC. PANEL LOCATION#2' - 8" 6' - 8"1#3' - 0" 6' - 8"2EXISTINGEXIT#2' - 8" 6' - 8"32' - 2"4"11' - 0" 13' - 6"5' - 4"4' - 0"9' - 8"2' - 6"2' - 0"19' - 4"EXISTING 2HR RATED WALLEXISTING 2HR RATED WALL1 4-24-24EXISTING 2HR RATED WALLEXISTING 2HR RATED WALL14-24-24 CEILING MOUNTED EXHAUST/ LIGHT FAN 2x4 CEILING FLUORESCENT LIGHT SYMBOL LEGEND SEE LIGHTING PLAN BY MEP DWG's FOR ADDITIONAL INFO PENDANT LIGHT 2x4 CEILING FLUORESCENT LIGHT 2x4 CEILING FLUORESCENT LIGHT ELECTRICAL OUTLET WALL MOUNTED LIGHT 421 East SR 434, Suite 1015, Longwood, Florida 32750 JOHN D. YOUNGMAN ARCHITECT AR 9601 SCALE PROJECT. NUMBER DATE: DRAWN SHEET AS SHOWNSCALE DRAWN BY: CHECKED BY:SHEET TITLEPROJECT:COPYRIGHT © JOHN YOUNGMAN, ARCHITECT. THIS OR ANY OTHER DOCUMENT SHALL NOT BE COPIED, ALTERED, REPRODUCED WITH OUT THE WRITTEN CONSENT OF JOHN YOUNGMAN, ARCHITECT.PROJECT ISSUED FOR:THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY JOHN D. YOUNGMAN, ARCHITECT AR9601 ON DATE/ TIME STAMP SHOWN USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED. 421 East SR 434, Ste. 1015, Longwood, Florida 32750 PH. 407-781-6611 info@b2di.com BEYOND 2 DIMENSIONS, INC PLANNING, DESIGN, DRAFTING, PROJECT COORDINATION 4/30/2024 4:27:16 PM FLOOR PLANA101 On File RCARRION JY/ RC469 Atlantic Blvd Atlantic Beach32233TENANT PLANS FORSTATUSLIVING AREA Name Area FLOOR AREA 1012 SF TOTAL UNDER A/C 1012 SF SCALE: REF. SHEET: 1/4" = 1'-0" WALL TYPE LEGEND No.No.DescriptionDescription DateDate 1 COMMENT 4-24-24 SCALE: REF. SHEET: 1/4" = 1'-0"A101 UNIT PLAN3 SCALE: REF. SHEET: 1/4" = 1'-0"A101 EXISTING RCP PLAN1 SCALE: REF. SHEET: 1/4" = 1'-0" CEILING LEGEND DIVISION 8: DOORS AND HARDWARE 1. DOOR AND HARDWARE GENERAL NOTES: A. ALL DOOR COMPONENTS SHALL BE FURNISHED, INSTALLED AND FINISHED BY THE GC, UNLESS NOTED OTHERWISE.UTILIZE 3'-0" PRE-MACHINED, PRE-FINISHED, SOLID CORE FLUSH WOOD DOORS WITH METAL FRAMES AND LEVERACTION MORTISE HARDWARE. THE CM AND/OR LANDLORD SHALL COORDINATE, BETWEEN THE GENERAL CONTRACTOR AND THE TENANT, THE KEYING OF ALL LOCKSETS. ALL DOORS SHALL BE INSTALLED WITH A HINGE JAMB 6" FROM THE PERPENDICULAR/INTERSECTING WALL UNLESS NOTED OR INDICATED OTHERWISE. B. INSTALL WALL STOPS OR FLOOR STOPS ON ALL INTERIOR DOORS: CONCAVE 2-3/8" DIAMETER. C. .DOOR-MOUNTED KICK-STOPS ARE NOT ALLOWED ON ENTRY OR EXIT DOORS. D. ALL HINGES ARE TO BE OF THE BALL BEARING TYPE NOTED IN THE LIST ABOVE. E. KEY LOCKS ARE NOT ALLOWED ON INSIDE EXIT DOORS. F. ALL (REUSED) DOORS WITHIN ANY RENOVATION SPACE MUST BE REFURBISHED TO "LIKE NEW" CONDITION. G. ALL ENTRY AND EXIT DOORS AND FRAMES LEADING TO PUBLIC CORRIDORS MUST BE 20 MINUTE RATED. H. ALL EXIT DOORS MUST BE EQUIPPED WITH PANIC HARDWARE PREPARATION FOR HARDWARE: 1. REINFORCE COMPONENTS FOR HARDWARE INSTALLATION IN ACCORDANCE WITH SDI-100-83. 2. PUNCH SINGLE LEAF FRAMES TO RECEIVE THREE SILENCERS; DOUBLE LEAF FRAMES TO RECEIVE TWO SILENCERS PERLEAF, AT HEAD. 3. FACTORY PREPARED HARDWARE LOCATIONS SHALL BE IN ACCORDANCE WITH "RECOMMENDED LOCATIONS FORBUILDERS HARDWARE FOR STANDARD STEEL DOORS AND FRAMES", AS ADOPTED BY THE STEEL DOOR INSTITUTE. GENERAL NOTES: 1. DO NOT SCALE THESE DRAWINGS. 2. THE INTENT OF THESE DRAWINGS IS TO INDICATE THE SCOPE OF WORK REQUIRED IN ORDER TO CONSTRUCT A COMPLETE AND FINISHED SPACE READY FOR TENANT OCCUPANCY. THE CONTRACTOR AND SUB-CONTRACTORS ARE EXPECTED TO VISIT THE PROJECT SITE PRIOR TO CONSTRUCTION AND NOTIFY THE ARCHITECT - PRIOR TO CONSTRUCTION - OF ANY DISCREPANCIES WITHIN THE DRAWINGS OR POSSIBLE CONFLICTS WHICH AFFECT THE PROGRESS OF THIS PROJECT. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS NOTIFYING THE ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE PROJECT. 3. ALL DIMENSIONS ON FLOOR PLANS ARE FROM FACE OF WALL TO FACE OF WALL, UNLESS NOTED OTHERWISE. 4. VERIFY EXISTENCE OF FIRE ALARM AND DETECTION SYSTEMS. INCLUDE IN THE BID PRICE ANY WORK REQUIRED TO MODIFY EXISTING SYSTEM, IN ORDER TO COMPLY WITH LOCAL AND FEDERAL CODES - NO CHANGE ORDERS WILL BE ACCEPTED FOR ANY FIRE DETECTION OR ALARM SYSTEM MODIFICATIONS. 5. WHERE NEW CONSTRUCTION JOINS EXISTING SURFACES MATCH AND ALIGN NEW FINISHES WITH THE EXISTING. 6. SEAL ALL PENETRATIONS OF FIRE-RATED WALL ASSEMBLIES, IF APPLICABLE IN ACCORDANCE WITH U.L. FIRE-RATED PENETRATION DETAIL(S). 7. PROVIDE FIRE EXTINGUISHERS HAVING A MINIMUM RATING OF 2-A, 10-B,C FOR EVERY 3000 SQUARE FEET OF FLOOR AREA. TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. - MOUNT BOTTOM AT 2'-9 1/2" A.F.F. - EXISTING FIRE EXTINGUISHERS AND CABINETS MAY BE RECHARGED, REFURBISHED AND REINSTALLED IN THE APPROPRIATE LOCATIONS AS DIRECTED BY THE LOCAL FIRE INSPECTION OFFICIAL IN LIEW OF PURCHASING NEW EXTINGUISHERS, HOWEVER, IF REQUIRED CONTRACTOR WILL ALSO PROVIDE AND INSTALL NEW ADDITIONAL EXTINGUISHERS TO MEET CURRENT CODES. 8. REFER TO MECHANICAL, ELECTRICAL, & PLUMBING DRAWINGS FOR ALL MECHANICAL, PLUMBING, AND ELECTRICAL WORK REQUIRED. 9. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE LOCAL CODES AND RESTRICTIONS 10. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL BE USED ONLY BY THE SUPERINTENDANT. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES. THESE ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT 11. TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND THE WORKERS AT ALL TIMES. 12. CONTRACTOR TO SUBMIT (2) SAMPLES OF CARPET AND (1) SEAMING DIAGRAM INDICATING WHICH CARPET IS TO BE INSTALLED IN EACH LOCATION FOR ARCHITECT/ TENANT APPROVAL PRIOR TO PLACING CARPET ORDER. 13. INSTALL NEW ROOFTOP EQUIPMENT CURBS OR SUPPORTS AS REQUIRED AND PROVIDE FLASHING MATERIALS COMPATIBLE WITH EXISTING ROOFING SYSTEM. SEAL ANY NEW PENETRATIONS OF THE EXISTING ROOF ASSEMBLY TO MAKE WATER TIGHT. COORDINATE WITH OWNER'S REPRESENTATIVE TO ENSURE THAT ANY REQUIRED ROOFING WORK WILL NOT VOID AN EXISTING ROOF WARRANTY. 14. INTERIOR STEEL FRAMED GYPSUM BOARD PARTITION DESIGN CRITERIA IS BASED ON THE CLARK STEEL FRAMING SYSTEMS "CALCULATED NON-STRUCTURAL ALLOWABLE HEIGHTS TABLE". ALLOWABLE DEFLECTION WITH A 5 PSF UNIFORM LOAD PERPENDICULAR TO THE PARTITION IS L/240. PARTITIONS WITH CERAMIC TILE FINISH SHALL HAVE AN ALLOWABLE DEFLECTION OF L/360. CONTRACTORS TO SUBMIT LIMITING HEIGHT TABLES FOR OTHER MANUFACTURERS SELECTED. DIVISION 9: FINISHES: THE GENERAL CONTRACTOR MUST SUBMIT SAMPLES OF ALL FINISHES TO THE CM AND THE TENANT AT LEAST TWO (2) WEEKS IN ADVANCE OF THE ORDER DATE FOR APPROVAL PURPOSES (IN ORDER TO ALLOW TIME FOR RE- SUBMITTALS) PRIOR TO ORDERING ANY MATERIALS. GENERAL FINISH CRITERIA 1. ALL INTERIOR FINISHES SHALL BE CLASS "A" OR BETTER. 2 IT IS THE RESPONSIBILITY OF ALL INSTALLERS AND SUBCONTRACTORS TO VERIFY EXISTING FIELD CONDITIONS PRIOR TO ORDERING MATERIALS AND INSTALLATION. 3 FINISH SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROPER SUBSTRATE PREPARATIONS PRIOR TO APPLICATION /INSTALLATION OF FINISH MATERIAL. 4. WHEREVER EXISTING FINISHES ARE TO REMAIN, THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT THEM. 5. PROJECT CLEAN-UP SHALL INCLUDE A "VACUUM CLEAN" INTERIOR SPACE WITH RESTORATION TO ALL DAMAGED SURFACES AND ITEMS TO "LIKE NEW CONDITIONS. 6. PROVIDE THE FOLLOWING INFORMATION ON THE CONSTRUCTION DOCUMENTS: 7. INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH FBC 2017 TABLE 803.11 ALL INTERIOR FINISHES SHALL MEET THE REQUIREMENTS OF FBC 803.1.1 FOR CLASS A, FLAME SPREAD INDEX 0-25 AND SMOKE DEVELOPED INDEX 0-450 NOTE: EPOXY PAINT AT FIXTURE WALLS OF TOILETS. ALL MATERIALS, COLORS, AND TEXTURES SELECTED BY OWNER.