Loading...
469 Atlantic Blvd Unit 9 COMM24-0011 Pg A001 - 2N A1B1 A901 C1 D1A901 A1 00 AA A901 A1 A W2 1 1 A1 A901 SYMBOLS WINDOW DESIGNATION DOOR DESIGNATION TAG NOTE WALL TYPE REVISION NORTH ARROW ELEVATION TAG DETAIL DETAIL - ENLARGED PLAN SHEET WHERE SECTION IS DRAWN SECTION DETAIL NUMBER DETAIL NUMBER ELEVATION NUMBER ELEVATION NUMBER AND KEY SHEET WHERE ELEVATION IS DRAWN INTERIOR ELEVATION SHEET WHERE ELEVATION IS DRAWN AREA TO BE DETAILED OR ENLARGED SHEET WHERE DETAIL IS DRAWN WALL/ BUILDING SECTION NUMBER SHEET WHERE SECTION IS DRAWN D7 APPLICABLE CODES & STANDARDS BUILDING:FLORIDA BUILDING CODE 8th EDITION (2023 FIRE / LIFE SAFETY:FLORIDA FIRE PREVENTION CODE 8th EDITION (2023 NFPA 1, FIRE CODE - FLORIDA AMENDED 2021 EDITION NFPA 101, LIFE SAFETY CODE - FLORIDA AMENDED 2017 EDITION PLUMBING:FLORIDA BUILDING CODE 8th EDITION (2023 - PLUMBING FLORIDA BUILDING CODE 8th EDITION (2023 - FUEL GAS MECHANICAL:FLORIDA BUILDING CODE 8th EDITION (2023 - MECHANICAL ELECTRICAL:FLORIDA BUILDING CODE 8th EDITION (2023 - CHAPTER 27 NFPA 70, NATIONAL ELECTRICAL CODE - 2017 EDITION (BY REFERENCE) ENERGY:FLORIDA BUILDING CODE 8th EDITION (2023 - ENERGY CONSERVATION BUILDING:TYPE V-B CONSTRUCTION, UN-SPRINKLERED NOTE: SEE PLANS FOR UL ASSEMBLIES TO PROVIDE REQUIRED FIRE RESISTANCE OF BLDG. ELEMENTS ACCESSIBILITY:FLORIDA BUILDING CODE 8th EDITION (2023 - ACCESSIBILITY TESTING FOR HVHZ:FLORIDA BUILDING CODE 8th EDITION (2023 - TEST PROTOCOLS 421 East SR 434, Suite 1015, Longwood, Florida 32750 JOHN D. YOUNGMAN ARCHITECT AR 9601 SCALE PROJECT. NUMBER DATE: DRAWN SHEET AS SHOWNSCALE DRAWN BY: CHECKED BY:SHEET TITLEPROJECT:COPYRIGHT © JOHN YOUNGMAN, ARCHITECT. THIS OR ANY OTHER DOCUMENT SHALL NOT BE COPIED, ALTERED, REPRODUCED WITH OUT THE WRITTEN CONSENT OF JOHN YOUNGMAN, ARCHITECT.PROJECT ISSUED FOR:THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY JOHN D. YOUNGMAN, ARCHITECT AR9601 ON DATE/ TIME STAMP SHOWN USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED. 421 East SR 434, Ste. 1015, Longwood, Florida 32750 PH. 407-781-6611 info@b2di.com BEYOND 2 DIMENSIONS, INC PLANNING, DESIGN, DRAFTING, PROJECT COORDINATION 4/1/2024 9:08:59 PM COVER SHEETA001 On File RCARRION JY/ RC469 Atlantic Blvd Atlantic Beach32233TENANT PLANS FORSTATUSNOTICE TO BUILDERS AND CONTRACTORS: PLEASE REVIEW THESE PLANS TO THE FULLEST PRIOR TO BUILDING, ERECTING, AND OR MATERIAL ORDERING AS NEEDED BUILDERS AND CONTRACTORS ARE RESPONSIBLE FOR READING PLANS AND PROVIDE IN WRITING TO ARCHTECT OR ENGINEERS OF ANY DESCREPANCIES AND OR OMISSION AND DESIGNER OF RECORD IS NOT RESPONSIBLE FOR ANY CHARGE BACKS AS SUCH No.No.DescriptionDescription DateDate INTERIOR BUILD-OUT FOR: 469 ATLANTIC BLVD ATLANTIC BEACH 32233 HOLEY MOLEY NY BAGEL 2 LLC 469 ATLANTIC BLVD. UNIT#9, ATLANTIC BEACH FL. 32223 PARCEL # 41-04-26-018616-001-00 AIR CONDITIONING ARCHITECT /ENGINEER ABOVE FINISH FLOOR AIR HANDLING UNIT ARCHITECTURAL ACOUSTICAL PANEL CENTER TO CENTER CONSTRUCTION JOINT DRINKING FOUNTAIN ELECTRICAL WATER EXPANSION JOINT FIRE DEPARTMENT FIRE DEPARTMENT FIRE EXTINGUISHER FIRE HOSE CABINET FACE OF CONCRETE CONCRETE MASONRY FACE OF MASONRY EASTE FPRFFIREPROOFING FT FTG FWC FOOT, FEET FOOTING FABRIC WALL COVERING ELEC ELEV EQUIP EXIST EXP JT FIN FL FIN GR FLUOR FDC FOC FOM FOS FLR FIN FHC FEC FDV EXT "F" FD EQ EWC EL EA CONNECTION VALVE CABINET FINISH FINISH FLOOR FLOOR FINISH GRADE FLUORESCENT FACE OF STUD ELECTRICAL ELEVATION ELEVATOR EQUAL EQUIPMENT COOLER EXISTING EXTERIOR EACH FLOOR DRAIN CC, C/C CLG HT CONC CONT DIM "E" DWG DN DS DR DET DF DIA DIAG "D" CPT CJT COL CLG CMU "C" CJ CIP BOT BUR CARPET DETAIL DIAMETER DIMENSION DOWN DOOR DOWNSPOUT DRAWING DIAGONAL BOTTOM CEILING UNIT CONCRETE CONTINUOUS COLUMN BUILT-UP ROOF CAST IN PLACE CONTROL JOINT CEILING HEIGHT AC or A/C ALUM APPROX ARCH ACOUS PNL BLDG BLKG "B" BLK AFF AHU ALT "A" A/E ALTERNATE ALUMINUM ARCHITECT, BUILDING BLOCK BLOCKING APPROXIMATE ARCHITECTURE, TST TOP OF STEELNOT APPLICABLENA TYP UON UPS UNFIN VCT VERT VWC W/O WDW WWF PRESERVATIVEPT TREATED PAVEMENT PAINTEDPVMT PTD NUMBER OVERALL NOISE REDUCTION COEFFICIENT NOT TO SCALE ON CENTER OFFICE OPENING OPPOSITE ORIGINAL OUTSIDE DIMENSION OPPOSITE HAND OVERHEAD OUTSIDE DIAMETER/ NOT IN CONTRACT PLATE PLASTER PANEL PAIR PLYWOOD PLASTIC LAMINATE PREFABRICATED PREFINISHED PREPARATION PRELIMINARY OPP ORIG OVHD PL PLAM PLAS PNL PR PREFAB PREFIN PLYWD PREP PRELIM "P" NO NTS NRC "O" OA OC OFF OPNG OPH OD NIC WI WP WF WD WC W/ W "W" "V" "U" TW UNLESS OTHERWISE VINYL COMPOSITION TILE, OR VITRIFIED VINYL WALL COVERING VERTICAL WITHOUT WINDOW FABRIC WATER CLOSET WOOD, WIDTH WIDE FLANGE WORKING POINT WELDED WIRE WROUGHT IRON WEST WITH TYPICAL UNFINISHED NOTED CLAY TILE UNINTERRUPTIBLE POWER SUPPLY TOP OF WALL REF REINF REQD REFL SHT SCHED SECT SPEC SQ FT STC STD STL SST SIM SUSP SYM SYMM T&G TSL THK TEL STRUCT MASONRY INSULATION INSIDE DIAMETER JANITOR JOINT LAVATORY JOIST INTERIOR MAXIMUM MEZZANINE MAINTENANCE MECHANICAL MANUFACTURING MINIMUM NORTH MULLION MISCELLANEOUS MASONRY OPENING MANUFACTURER LIGHT WEIGHT MAS MAINT MAX MFG MECH MEZZ MIN MO MISC MULL MFR N "N" INSUL JAN JST LAV INTR LT WT "M" "L" JT "J" "I" ID TF TS TJ TFF T "T" SQ GAUGE GALVANIZED GRADE GYPSUM HEIGHT GYPSUM BOARD GYPSUM PLASTER HOLLOW CORE GLASS HOLLOW METAL DOOR HOLLOW METAL FRAME HEATING, VENTILATION, AIR CONDITIONING HOLLOW METAL GR GYP GYP BD HC HGT GYP PLAS GL HMD HMF HVAC HM "H" GA GALV "G" SC S "S" RM RO RD "R" R QT "Q" SOUND TRANSMISSION TREAD GROOVE FLOOR THICKNESS SYMMETRICAL TONGUE AND TELEPHONE TOP OF FOOTING TOP OF FINISH TOP OF JOINT TUBE STEEL TOP OF SLAB SCHEDULE SECTION SHEET SQUARE CLASS STANDARD STEEL SIMILAR SPECIFICATION SQUARE FOOT STAINLESS STEEL SYMBOL SUSPENDED STRUCTURAL REQUIRED RISER / RADIUS ROOF DRAIN REFERENCE REFLECTED REINFORCED, REINFORCING, REINFORCE SOUTH ROUGH OPENING SOLID CORE ROOM MENT QUARRY TILE ABBREVIATIONS DIMENSION NOTE: WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR DIMENSIONS AND CONDITIONS OF THE JOB AND THE ARCHITECT OF RECORD MUST BE NOTIFIED IN WRITING OF ANY VARIATION FROM THE DIMENSIONS, CONDITIONS AND SPECIFICATIONS APPEARING ON THESE PLANS. TO THE BEST OF MY KNOWLEDGE: THESE CONTRACT DOCUMENTS, PREPARED UNDER MY DIRECT SUPERVISION, COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODE REQUIREMENTS AND FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTERS 553 AND 633 OF THE FLORIDA STATUTES. LANDLORD: DIAMOND REAL ESTATE PROPERTIES IV, LLC 0312 ATLANTIC BLVD. JACKSONVILLE, FLORIDA 32225 PHONE (904)-813-6648 TENANT: ANA M CAMACARO AND RONALD PERFETTI 2130 MAYPORT RD. APT. 1703 JACKSONVILLE FL. 32233 ANACAMACARO62@GMAIL.COM PHONE (305)-915-3948 ARCHITECT: JOHN D YOUNGMAN, ARCHITECT, AR9601 421 E. SR 434 SUITE 1015 LONGWOOD, FL. 32750 PACSUPPORT@B2DI.COM PHONE (407) 781-6611 COORDINATION: RICHARD A. CARRION BEYOND 2 DIMENSIONS, INC. 421 E. SR 434 SUITE 1015 LONGWOOD, FL. 32750 INFO@B2DI.COM (407) 781-6611 NOTICE TO BUILDERS AND CONTRACTORS: PLEASE REVIEW THESE PLANS TO THE FULLEST PRIOR TO BUILDING, ERECTING, AND OR MATERIAL ORDERING AS NEEDED BUILDERS AND CONTRACTORS ARE RESPONSIBLE FOR READING PLANS AND PROVIDE IN WRITING TO ARCHTECT OR ENGINEERS OF ANY DESCREPANCIES AND OR OMISSION AND DESIGNER OF RECORD IS NOT RESPONSIBLE FOR ANY CHARGE BACKS AS SUCH UNIT 322 SHEET INDEX Sheet NumberSheet Name Current Revision Date A001COVER SHEET A101FLOOR PLAN A102LIFE SAFETY PLAN A103DETAILS Property Description E 820 FT OF S1/4 OF SE1/4 OF SE1/4 (LESS BEG 74 FT N & 30 FT W OF SE COR OF SE 1/4 FOR POB RUN S 88 DEG W 50 FT N 01 DEG W 50 FT N 88 DEG E 50 FT S 01 DEG E 50 FT TO POB & LESS E 30 FT FOR RD R/W) OF SEC 10-22-30 & LESS PT FOR R/W PER 6350/4583 & C101-5801) VICINITY MAP N.T.S. AERIAL MAP N.T.S.