808 AMBERJACK LN RES24-0044 FL23157_R2_II_SS FL 23157.1 REPORT AND INSTALL DETAILS REV 5-16-24i>P, C-CL;\0' P E T E R S E N Product Report Manufacturer: Petersen Aluminum Corporation 102 Northpoint Parkway Building 106 Acworth, GA 30102 (BOO) 272-4482 Florida Product Approval# 231S7 Soffit Panels NON-HVHZ Compliant with Florida Building Code 2023 (8th ed.) FBC 2023 Sec. 1709.10, Sec. 1404.5, Sec. 1405.2, 1405.11 Compliant with Florida Product Approval Rule # 61620-3 Compliant Quality Assurance Program: UL LLC FL 23157.1 Product: Flush Panel (0.032") 12" wide x 0.032" Aluminum Soffit Panel NON-HVHZ Attached to 16GA support member or equivalent substrate secured with fasteners through the long lap leg, and side lap stitch fasteners In vertical legs. FBC Sec. 1405.11.1 & .2 Corrosion Resistant, additional requirement of (4) fasteners If the area supported exceeds (4) square feet. Panels are 12" wide with 1" right angle vertical legs, configured with nesting capabilities. Corrosion Resistant Compliant Fastener #10 x 1" Pancake Head fastened at each support to 16 GA Zeebar substrate or equivalent, #14 x 7/8" stitch lap fastener at 24" o.c. No pressure equalization factors have been used In analysis and panel may be used as a wall panel. Applicable load tables are included from testing and Petersen Aluminum Corporation. MATERIAL: .032"AWM .040" ALUM 24GASTEEL 22GASTEEL PANEL SP ANS: 12" 48" 12" 48" 24• 60" 24" 60" ULTIMATE PSF LOAD/ -80/-40 -50/-25 -290/-145 -80/-40 -165/-82.5 -100/-50 -210/-105 -140/-70 2.0 SAFTEY FACTOR* Limitations and Conditions of Use: 1.Products herein this report are compliant with current Florida Building Code (FBC)2023 9TH ed. 2.Install in compliance with FBC 2023., Install per Manufacturer's installation reference. 3.Product compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-0 4.Engineering analysis for "project specific project �pproval" to determine appropriate wind safety factors; is allowed by other Florida licensed professionals. 5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing compliant w/FBC 2023 8th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report.Test References: Fenestration Testing Lab TST 1657 Test # 7584-A ASTM 1592-051( 2005) EQUIVALENCY: ASTM E 1592-05, test standards are equivalent to ASTM E 1592-2015 test standards Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturins or distributing products under this evaluation. ,,,,,1111,,,,,, '' O BO ,,, ,,'�1� . i,v,'/) ,,,, Locke Bowden, P .E. is not owned, operated or controlled by any company manufacturing or distributing products under this report. ...... fv'f:"- • • • • • • � ,,. $' 0 • \)CENS£' • • 1,, � � .......,,_. ·. � f: N°Btl •• �� :�-. � -�· p ·�-<1/J .? ; �··. STATE Of ..-�J o L 1 q 2..-y \_ 0� • • .�l ORIO!• �&�l ,,. �s ••••• t:� '"" ,,,,,, °SIONA\. ';,.,.,,' ,,,,,,.111"''' PAC-CLAD FLUSH PANEL r.05/14 #10 PANCAKE HEAD FASTENER@ EACH SUPPORT 16GA SUPPORT EQUIV IL ENT PAC-CLAD 12• FLUSH PANEL #14 X 7/8" LAP FASTENER@ 24" 0/C ATTACHMENT DETAIL ...L__ 1.0� 7=�--r L 12.aaao-----1- □1MENs10Ns ISOMETRIC VIEW Petersen Aluminum Corporation 102 Northpolnt Parkway Building 106Acworth GA 30102Toll Free: 800-272-4482 Fax: 770-420-2533 www.pac-clad.com *optional pencil ribs available