808 Amberjack Lane-RES24-0044 ARCH DWGSGENERAL NOTES: 1.IT IS THE INTENT THAT THIS WORK BE IN CONFORMANCE WITH THE FLORIDA BUILDING CODE 2017, 6TH ED. RESIDENTIAL AND ALL AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. CONTRACTOR SHALL DO THEIR WORK IN CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS. 2.THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. 3.THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF THE ENGINEER AND MAY NOT BE USED OR REPRODUCED WITHOUT EXPRESSED WRITTEN CONSENT OF THE ENGINEER. 4.ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 5.CONTRACTOR WILL INCORPORATE ALL NECESSARY LOCAL/STATE/FEDERAL BUILDING, FIRE, AND HANDICAP CODES INTO THE DESIGN AND BASE PROPOSAL FOR A COMPLETE TURN-KEY PROJECT. 6.PROJECT SHALL BE TURNED OVER TO OWNER IN A CLEAN CONDITION WITH ALL TRASH AND DEBRIS REMOVED FROM SITE. ALL WINDOWS AND CLASS CLEAN, ALL FLOORS CLEAN, ALL HORIZONTAL SURFACES DUSTED AND CLEANED, AND ALL PLUMBING AND TOILET FIXTURES CLEAN AND IN GOOD WORKING ORDER. CONTRACTOR SHALL HAUL ALL RUBBISH FROM SITE ON A REGULAR BASIS. DO NOT ALLOW TO ACCUMULATE. 7.CONTRACTOR TO OBTAIN ALL PERMITS, PAY ALL FEES AND TAXES. CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP FREE FROM DEFECTS. FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE ION AND SHALL INCLUDE INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 8.DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATION BY THE OWNER. 9.A DESIGNATED LOCATION FOR STORAGE OF CONSTRUCTION MATERIAL AND EQUIPMENT SHALL BE DETERMINED BY THE OWNER AND IDENTIFIED AT THE PRE-CONSTRUCTION MEETING. 10.CONTRACTOR PERSONNEL ARE CONFINED TO AREAS OF BUILDING NECESSARY FOR COMPLETION OF WORK. FREE ACCESS TO ALL PARTS OF THE BUILDING IS NOT ALLOWED. 11.CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNCRATING, SORTING, SETTING IN PLACE, AND PROTECTING FROM DAMAGE ALL NEW EQUIPMENT FURNISHED BY THE CONTRACTOR. THIS SHALL ALSO APPLY TO ITEMS FURNISHED BY THE OWNER TO THE CONTRACTOR. 12.TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 13.TERMITE PROTECTION TO BE DONE AFTER ALL EXCAVATION, BACKFILLING AND COMPACTION IS COMPLETE. ANY DISTURBED SOIL TREATMENT MUST BE RETREATED. 14.TREATMENT SHALL BE PROTECTED FROM RAINFALL BY 6 MIL VAPOR BARRIER. IF RAINFALL OCCURS BEFORE BARRIER PLACEMENT, SOIL MUST BE RETREATED. 15.PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB-ON-GRADE FLOORS SHALL BE NON-CELLULOSE CONTAINING MATERIALS AND RECEIVE AN APPLICATION OF TERMITICIDE IN ANNULAR SPACE BETWEEN SLEEVE AND PIPE. A-0Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027CONSTRUCTION PLANS FOR NEW SINGLE FAMILY LOCATED AT 808 AMBERJACK LANE ATLANTIC BEACH, FL 32233 BUILDING STRUCTURE INFORMATION: UNCONDITIONED SPACE: GARAGE.........................................................................400 S.F FRONT PORCH................................................................95 S.F CONDITIONED SPACE: 1ST FLOOR....................................................................956 S.F. 2ND FLOOR...................................................................1,264 S.F TOTAL CONDITIONED:................................................2,220 S.F. TOTAL SPACE:.......................................................................2,715 S.F. CONDITIONED VOLUME........................................................18, 716 CU.FT. TYPE OF CONSTRUCTION..................................................5B OCCUPANCY:..........................................................................R-3 FIRE SPRINKLERS:................................................................NO MAX HEIGHT OF STRUCTURE............................................<35' WIND BORNE DEBRIS REGION...........................................NO NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233GENERAL NOTESPlan Sheets Label Title A-0 GENERAL NOTES A-1 ELEVATIONS-1 A-2 ELEVATIONS-2 A-3 FLOOR PLAN A-4 ROOF PLAN & SECTIONS A-5 ELECTRICAL LAYOUT A-6 PLUMBING PLAN A-7 FLASHING DETAILS THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES ELECTRICAL NOTES: 1.ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH 2020 FLORIDA BUILDING CODE, 7TH EDITION, RESIDENTIAL AND NFPA 70 2020 NATIONAL ELECTRIC CODE (NEC). 2.ALL SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE IN ACCORDANCE WITH THE SECTION R314 OF 2020 FLORIDA BUILDING CODE, 7TH EDITION. 3.ELECTRICAL CONTRACTOR SHALL PROVIDE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION IN KITCHENS, BATHROOMS, LAUNDRY, GARAGES, AND OUTDOORS PER 2020 NEC 210.8 (A) 4.ELECTRICAL CONTRACTOR SHALL PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION IN LIVING, DINING, HALLWAYS, AND BEDROOMS PER 2020 NEC 210.12 (A) 5.ALL OUTDOOR RECEPTACLES SHALL BE PROTECTED FROM MOISTURE PER 2020 NEC 406.9 6.ALL PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL COMPLY WITH THE MINIMUM REQUIREMENTS PER FBC-ENERGY CONSERVATION R404. 7.ELEVATORS SHALL BE IN ACCORDANCE WITH FBC 2020, 7TH ED, SECTION R321.1 MECHANICAL NOTES: 1.ALL DUCT SIZING SHALL BE IN ACCORDANCE W/ ACCA MANUAL "D". PROVIDE DUCT TESTING IN ACCORDANCE W/ ASHRAE STANDARD 152. 2.DUCT LAYOUT AND ALL OTHER MECHANICAL COMPONENTS ARE SHOWN ON THE APPROVED DUCT LAYOUT PLAN INCLUDED IN THE ENERGY CALCULATION PACKAGE PERFORMED BY OTHERS. 3.ALL DUCTS & AIR HANDLERS NOT LOCATED IN CONDITIONED SPACE SHALL BE TESTED TO BE "SUBSTANTIALLY" LEAK FREE. 4.DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE INSTALLED ACCORDING TO FBC R302.5.2 5.ALL INSULATION SPECIFICATIONS ARE INCLUDED IN THE ENERGY CALCULATION PACKAGE PERFORMED BY OTHERS. IF ANY INSTALLED INSULATION MATERIALS DO NOT MATCH THE ENERGY FORMS, NEW CALCULATIONS SHALL BE PERFORMED OR THE ORIGINAL APPROVED INSULATIONS SHALL BE INSTALLED. 6.ELEVATORS SHALL BE IN ACCORDANCE WITH THE FBC 2017, 5TH ED., SECTION R321.1 PLUMBING NOTES: 1.ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. 2.ALL EXCAVATION & BACK FILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT, 3.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO A VOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 4.VERIFY LOCATION, SIZE, TRAPS, INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. ANY COST RES UL TING FROM DISCREPANCIES NOT REPORTED AT THIS TIME SHALL BE PAID BY THE CONTRACTOR. 5.WATER PIPING TO BE TYPE "M" OR TYPE "L" COPPER ABOVE OR BELOW GRADE. 6.SOIL, WASTE & VENT PIPING TO BE PVC. #40 DVW. 7.ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS 8.WHERE DISSIMILAR METALS ARE TO BE JOINED, APPROVED INSULATING UNIONS SHALL BE USED. 9.INSULATE HOT WATER LINES WITH 1" THICK SNAP ON INSULATION FIRST 8 FEET FROM WATER HEATER. 10.CONDENSATE LINES TO BE COPPER/PVC DEPENDING ON PROJECT REQUIREMENTS. 11.INSULATE WITH 1/2" THICK ARMAFLEX INSULATION. 23-1017 DATE: AS NOTED 5 : 12 5 : 1212 5 F.F.E. - 1st Floor0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor 18'-7"8'-1 1/8"Highest Ridge26'-4 3/4"7'-9 3/4"F.F.E. - 1st Floor0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor 18'-7"8'-1 1/8"Highest Ridge26'-4 3/4"7'-9 3/4"26'-4 3/4"ASPHALT SHINGLES FIBER CEMENT B & B FIBER CEMENT LAP SIDING STONE VENEER SKIRTTAPERED POST W/16" STONE VENEER COL. BASE 12" WOOD SHUTTERS 1X8" HEADER 1X F. C. CORNER BOARDS 12 5 5 : 12 5 : 12 5 : 12 F.F.E. - 1st Floor 0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor18'-7"8'-1 1/8"Highest Ridge26'-4 3/4"7'-9 3/4"F.F.E. - 1st Floor 0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor18'-7"8'-1 1/8"Highest Ridge26'-4 3/4"7'-9 3/4"27'-0 3/4"FIBER CEMENT LAP SIDING ASPHALT SHINGLES 1X F. C. CORNER BOARDS 12 5 5 : 12 A-1Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233ELEVATIONS-11 A-1 1 A-1 2 A-1 2 A-1 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 23-1017 DATE: AS NOTED REAR ELEVATION SCALE: 1/4" = 1'-0" FRONT ELEVATION SCALE: 1/4" = 1'-0" 5 : 12 12 5 F.F.E. - 1st Floor0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor18'-7"8'-1 1/8"Highest Ridge 26'-4 3/4"7'-9 3/4"F.F.E. - 1st Floor0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor18'-7"8'-1 1/8"Ridge22'-10 3/8"4'-3 3/8"27'-0 3/4"22'-10 3/8"ASPHALT SHINGLES FIBER CEMENT LAP SIDING 1X F. C. CORNERBOARDS 12 5 5 : 12 5 : 125 : 12 12 5 F.F.E. - 1st Floor0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor 10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor18'-7"8'-1 1/8"Ridge22'-0 7/8"3'-5 7/8"Ridge22'-10 3/8"9 1/2"F.F.E. - 1st Floor0' FLT. HT. - 1st Floor9'-1 1/8"9'-1 1/8"F.F.E. - 2nd Floor 10'-5 7/8"1'-4 3/4"FLT. HT. - 2nd Floor18'-7"8'-1 1/8"Highest Ridge26'-4 3/4"7'-9 3/4"TAPERED POST W/ 16" STONE VENEER COL. BASE STONE VENEER SKIRT FIBER CEMENT LAP SIDING ASPHALT SHINGLES 1X F. C. CORNER BOARDS 5 : 125 : 12 A-2Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233ELEVATIONS-21 A-2 1 A-2 2 A-2 2 A-2 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 23-1017 DATE: AS NOTED RIGHT ELEVATION SCALE: 1/4" = 1'-0" LEFT ELEVATION SCALE: 1/4" = 1'-0" 1ST FLOOR PLAN SCALE: 1/4" = 1'-0" KITCHEN AND CABINET NOTES: 1.CONTRACTOR TO VERIFY DIMENSIONS & FIELD MEASUREMENT PRIOR TO ORDERING CABINETS. 2.CONFIRM CABINET COLOR WITH HOME OWNER PRIOR TO ORDERING. 3.CONFIRM DOOR & DRAWER STYLES WITH HOME OWNER PRIOR TO ORDERING. 4.INSTALL HARDWARE ON SITE. 5.INSTALL CROWN MOLDING ON SITE; MATCH CABINET COLOR; CONFIRM PROFILE AND DIMENSION WITH HOME OWNER. 6.CUT OVEN OPENING ON SITE, SEE APPLIANCE SPECIFICATIONS. 7.INSTALL HOOD AND ALL APPLIANCES PER MANUFACTURER SPECIFICATIONS. 8.ALL APPLIANCES TO BE ON DEDICATED CIRCUITS. 9.USE MIN 6" DUCT FOR HOOD. 10.CONFIRM FINAL MATERIALS FOR BACKSPLASH AND COUNTERTOP WITH HOME OWNER PRIOR TO ORDERING 2ND FLOOR PLAN SCALE: 1/4" = 1'-0" WH HB HB W05W05 D01D01 W01W01 W01W01 D05D05 W01W01W01W01 D03D03 D18D18 D02D02 D04D04 D08D08 D16D16 D03D03 UP 11 A-2A-2 2 A-4 2 A-4 1 A-4 1 A-4 CL10'-0"10'-0" CL 2'-0" CL 7'-3" CL 3'-2"3'-7" 4'-1"11'-11" 36'-0"10'-3 1/2"7'-9"16'-9 1/2"6"40'-0"6"5'-2"15'-1 1/2"CL 6'-4"CL 3'-2"CL 8'-6"CL 12'-0"6'-0" 36'-0"10'-0"4'-3 1/2"5'-5"20'-3 1/2"40'-0"4'-7"1'-3 1/2"4'-4 1/2"8'-0"3'-9"5'-11 1/2"5'-5"3'-7 1/2"2'-6"1'-4"6'-10 1/2"3'-5"4'-1"3'-8"6'-11 1/2" CL 5'-10"10'-2"1'-4"8'-11 1/2"2'-7"2'-0"2'-7"2'-0" 12'-1"23'-11"2'17'-3 1/2"3'-0"13'-3"10'-0"12'-9" 20'-0"16'-0"6" GARAGE PORCH BATH MUD LIVING ENTRY OFFICE/DEN DINING PANTRY MEDIA DESK REF. KITCHEN BENCHES 9 Clg 9 Clg 9 Clg 9 Clg 9 Clg 9 Clg 9 Clg 9 Clg 9 Clg 9 Clgw/Hood30" Range+MicrowaveTAPERED POST W/ 16" STONE VENEER COL. BASE PER BUILDERS SPEC. DW -4" 44 AHU 22AC COMPRESSOR 4"22 W.I.C. 8'x10' PATIO SLAB 66 17 RISERS @ 7-3/8" 33 WINDOW SCHEDULE NUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT BOTTOM DESCRIPTION COMMENTS AREA, ACTUAL (SQ FT) W01 3050SH 4 1 3050SH 36"60"20"SINGLE HUNG 15 W02 3050SH 7 2 3050SH 36"60"24"SINGLE HUNG 15 W03 4016FX 1 2 4016FX 48"18"62"FIXED GLASS 6 W04 3030SH 1 2 3030SH 36"36"44"SINGLE HUNG 9 W05 3030SH 1 1 3030SH 36"36"44"SINGLE HUNG 9 TOTALS: 189 DOOR SCHEDULE NUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT COMMENTS D01 6068 1 1 6068 L EX 72"80" D02 2668 1 1 2668 R IN 30"80" D03 2868 2 1 2868 L IN 32"80" D04 5068 1 1 5068 L/R IN 60"80" D05 16070 1 1 16070 192"84" D06 2868 3 2 2868 L IN 32"80" D07 3068 1 2 3068 36"80" D08 3068 1 1 3068 36"80" D09 5068 1 2 5068 L/R 60"80" D10 2868 1 2 2868 L 32"80" D11 2868 4 2 2868 R IN 32"80" D12 2068 1 2 2068 R 24"80" D13 4068 1 2 4068 L/R 48"80" D14 2868 1 2 2868 R 32"80" D15 1868 1 2 1868 R 20"80" D16 2068 1 1 2068 L IN 24"80" D17 2668 1 2 2668 R 30"80" D18 2868 1 1 2868 R IN 32"80" D19 5668 1 2 5668 L/R 66"80" SEE FL. PRODUCT APPROVALS AND STRUCTURAL PLANS FOR ALLOWABLE WIND PRESSURE REQ WALL SCHEDULE 2D SYMBOL WALL TYPE 2X6-SIDING 2X4-SIDING 2X6-INTERIOR 2X4-INTERIOR 2X4-INTERIOR_HALF INTERIOR RAILING GLASS SHOWER FBC NOTE SCHEDULE FBC-R807.1 -ATTIC ACCESS TO BE A MIN. 22"X30" IN SIZE IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION M1307.3.1-ALL APPLIANCES SHALL BE PROTECTED FROM VEHICLE IMPACT WITH APPROVED BARRIERS (WHEEL STOP, BOLLARD, CURB, ETC.) R311.7-ALL STAIRS, LANDINGS & RAILINGS TO BE IN ACCORDANCE WITH R311.7 HAZ GLAZ. PER R308.4.2 R31 0.2.1 -EMERGENCY ESCAPE AND RESCUE OPENINGS R312.1: GUARDS REQ. WHERE WALKING SURFACE, STAIRS, BALCONIES, LANDINGS ARE GREATER THAN 30" ABOVE LOWER WALKING SURFACE/GRADE. MIN. HT. SHALL BE 36" AND SPACING OF GUARDS SHALL NOT ALLOW PASSAGE OF 4" DIA. SPHERE 11 22 33 44 55 66 11 22 33 44 55 66 DN W02W02W02W02 W02W02 W02W02 W02W02 W04W04 D11D11 D07D07 D11D11 D12D12 D17D17 D06D06 D09D09 D15D15 D06D06 D06D06 D13D13 D14D14 D11D11 D11D11D10D10 D19D19 W03W03 W02W02W02W02 2 A-4 2 A-4 1 A-4 1 A-4 CLCL9'-11 1/2"2'-11 1/2" CL 4'-4" CL 3'-2"4'-4" CL 6'-3" CL 3'-2"6'-3" 15'-8"8'-6"11'-10" 36'-0" CL 4'-2" 6'-2"2'-4"1'-10"10'-7"7'-9"2'-6 1/2"13'-11 1/2"CL 3'-0"13'-1"2'-10"5'-6"2'-2 1/2"13'-0 1/2"36'-8"2'-3"CL 9'-2" 11'-11"8'-6"15'-7" 36'-0" 7'-0 1/2"2'-3 1/2" 3'-4 1/2" 2'-8"6'-5"1'-8"2'-7 3/4"9'-10 3/4"2'-10"1'-4 1/2"6'-4"3'-2 1/2"5'-9"4'-1"3'-5 1/2"5'-2 1/2"9'-4"2'-3"4'-0"6'-2 1/2"2'-3 1/2"2'-7"2'-1"7'-3"4'-2"4'-1 1/2"9'-0"2'-7 3/4"8 1/4"5'-0"11'-6"2'-7"2'-8 1/2"7'-3"2'-1"9" OPEN BELOW BEDROOM 1 BEDROOM 2BEDROOM 3 MASTER BEDROOM BATH MASTER BATH WALK-IN CLOSET LAUNDRY MEDIA CENTER KNEE SPACE W.C. 8 Clg 8 Clg 8 Clg 8 Clg 8 Clg 8 Clg 8 Clg 8 Clg 55 55 11 11 AccessAttic 11R & SR & SR & SR & SR & S R & S R & S R & SR & SW D AC CHASE Tub/ Shower 44 44Shower 1ST FLR. BELOW 1ST FLR. BELOW 66 A-3Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233FLOOR PLANTHIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 23-1017 DATE: AS NOTED TYP. WALL SECTION SCALE: 1/2" = 1'-0" INTERIOR STAIR DETAIL ALL STAIR REQ. TO BE IN ACCORDANCE WITH FBC-R311.75 : 121'-4" (O.H)1'-4"4'-7"38'-8"6'-6"ASPHALT SHINGLES ROOF 5:12 PITCH 5 : 12 5 : 125 : 12 5 : 125 : 125 : 121'-4"1'-4" (O.H)18'-4"5'-10"14'-6" 38'-8"37'-5"4'-1"39'-4"2'-3"ASPHALT SHINGLES ROOF 5:12 PITCH RIDGE HIPHIPHIPHIPRIDGERIDGEVALLEYVALLEY5/8" TYPE X GYPSUM CEILING MIN. OVER GARAGE AREAS ONLY. (IF REQ.) ROOF PITCH PER ELEVATIONS AND ROOF PLAN PRE-ENGINEERED ROOF TRUSSES PER SHOP DRAWINGS AND TRUSS LAYOUT ROOFING OVER 30# FELT OR APPROVED UNDERLAYMENT ON RATED SHEATHING PER STRUCTURAL PLANS. MTL. DRIP EDGE FASCIA BOARD. VENTED VINYL ALUMINUM SOFIT ROOFING MATERIALS PER ELEVATIONS & ROOF PLAN R-13 BATT INSULATION MIN. OR PER ENERGY SHEETS. IN COND. AREAS ONLY (BY OTHERS) APPROVED WEATHER BARRIER OVER SHEATHING WINDOW OR DOOR UNIT AS PER ELEVATIONS AND FLOOR PLAN. INSTALL PER FL. PRODUCT APPROVALS 1/2" GYPSUM W.B., FASTEN PER FBC TABLE R702.3.5 WINDOW SILL/HEAD PER BUILDERS SPEC. CAULKED @ WINDOW (FLASHING PER DETAILS) HEADER PER FRAMING PLAN DBL. 2x6 TOP PLATE FASTEN PER FRAMING PLAN 1/2" GYPSUM CEILING MIN. 2x4 No. 2 SPF EXTERIOR WALLS AT 16" O.C.,TYP. FLOOR TRUSSES PER TRUSS DESIGNER & STRUCTURAL PLANS, TYP. EXTERIOR COVERINGS SEE ELEVATIONS CLEAN COMPACTED FILL OR IN-PLACES SOILS. TERMITE TREATED SOIL OR ALTERNATIVE METHODS PER FBC. 2x6 P.T. SOLE PLATE 4" CONCRETE SLAB ON GRADE 2x6 WALL FRAMING, SEE FRAMING PLAN. SEE FOUNDATION PLAN FOR DETAILS. THIS IS FOR ILLUSTRATION PURPOSES ONLY AND MAY NOT REFLECT THE ACTUAL FOUNDATION SYSTEM. GRAD E 0'-0" FIN. FLR. R-13 BATT INSULATION MIN. OR PER ENERGY SHEETS. IN COND. AREAS ONLY (BY OTHERS) R-30 BLOWN INSULATION OR PER ENERGY SHEETS EXTERIOR COVERINGS SEE ELEVATIONS 9' -1 1/8" 1ST FLR. PLT. HT. 10'-5 7/8" 2ND FLR. F.F.E. 18' - 7" 2ND FLR. PLT. HT. CONV. FRAMED ROOF SYSTEM(1ST FLR). SEE ROOF FRAMING PLAN ROOFING OVER 30# FELT OR APPROVED UNDERLAYMENT ON RATED SHEATHING PER STRUCTURAL PLANS. MTL. DRIP EDGE WINDOW OR DOOR UNIT AS PER ELEVATIONS AND FLOOR PLAN. INSTALL PER FL. PRODUCT APPROVALS PRE-ENGINEERED ROOF TRUSSES PER SHOPDRAWINGS AND TRUSS LAYOUT EQUALLY SPACED RISERS7 3/4" MAX RISER BASE MOLDINGFINISH FLOORINGPLYWOOD SUBFLOOR AT TREAD AND RISERFULL STRINGER SOFFIT BLOCKING NOTCHEDSTRINGER 10" MIN. TREAD HANDRAIL HEIGHT 34" MIN. - 38" MAX.HANDRAIL GUARD SPACING/ OPENINGS TO NOT ALLOW PASSAGEOF 4" SPHERE GUARDS WHERE REQ. PER FBC-R312.1 TTA-4Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233ROOF PLAN & SECTIONSFRONT ISOMETRIC SCALE: N.T.S 1 A-4 1 A-4 2 A-4 2 A-4 LOWER ROOF PLAN SCALE: 1/4" = 1'-0" VENTILATION CALCULATIONS VENTILATION REQUIRED: ATTIC SPACE = 1,264 SQFT 1,264 / 300 = 4.21 SQFT 4.21 X 144 = 607 SQIN 607 X 0.5(50%) = 304 SQIN NET FREE ROOF VENT REQ'D 607 X 0.5(50%) = 304 SQIN NET FREE SOFFIT VENT REQ'D UPPER ROOF VENT SPECS: 4'-0" VENT PROVIDES 144 SQIN NET FREE SPACE 6'-0" VENT PROVIDES 216 SQIN NET FREE SPACE 8'-0" VENT PROVIDES 288 SQIN NET FREE SPACE UPPER ROOF VENT REQUIREMENTS: TYP. RIDGE VENT PROVIDES 18 SQIN/LIN. FT. NET FREE SPACE UPPER ROOF VENT REQUIREMENTS: 304 SQIN / 18 SQIN-LIN FT = 17 LIN FT. OF RIDGE VENT REQUIRED SOFFIT VENTS REQUIREMENTS: LIN. FT OF SOFFIT AVAILABLE = 154' AIR FLOW PER LIN. FT. = 5.89 SQIN TOTAL = 907 NET FREE SOFFIT AREA PROVIDED >304 SQIN REQUIRED VENTILATION REQUIREMENTS SHALL BE IN ACCORDANCE W/ SECTION R806.1 OF THE 2020 RESIDENTIAL FLORIDA BUILDING CODE. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 23-1017 DATE: AS NOTED SOFFIT DETAIL SCALE: N.T.S UPPER ROOF PLAN SCALE: 1/4" = 1'-0" 2ND FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1'-0" 1ST FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1'-0" WH HB HB UP R R GFCI GFCI GFCI 3 R R R R R R R R R R R GFCI 3 3 3 3 3 RGFCI GFCI GFCI GFCI GFCI C5/TV 3 GFCI GFCI GFCI M RA 3 3 GFCI GD GD R DW CO/SD CO/SD 3 GFCIWP GFCIWP GFCIWP EP TO STAIR LIGHT AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFIAFI AFI AFI AFI AFI AC DISC. D.W. GFCI ELECT. PANEL ELECTRICAL SCHEDULE 2D SYMBOL QTY DESCRIPTION COMMENTS 3 GFCI WEATHERPROOF RECEPTACLE 3 BARN PENDANT 1 CAT5 W/ TV 9 CO/SMOKE DETECTOR 1 CLOTHES DRYER 1 CLOTHES WASHER 6 CONTEMPORARY (3 LIGHTS) 4 CONTEMPORARY GLASS SCONCE 1 ELECTRICAL PANEL - RECESSED 1 GARBAGE DISPOSAL 27 DUPLEX 1 ELECTRIC RANGE GFCIWP C5/TV CO/SD CD CW EP GD RA GFCIWP C5/TV CO/SD CD CW EP GD RA DN CO/SD CO/SD R R R R R R R 4 4 4 CD CW R R R GFCI GFCI GFCI 3 3 R 3 3 3 3 3 CO/SD 3 CO/SD CO/SD CO/SD CO/SD TO SWITCH BELOW AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI AFI GFCI 4 EXHAUST (LIGHT) 3 FOUR WAY 16 GFCI 1 LONG SURFACE MOUNTED FLUORESCENT LIGHT [96W9D] 1 MICROWAVE 4 PORCH LANTERN 25 RECESSED DOWN LIGHT 6 1 REFRIGERATOR 23 SINGLE POLE 18 THREE WAY 1 DUPLEX, CEILING MOUNTED 1 GARBAGE DISPOSAL SWITCH 1 DISHWASHER 1 ARTS & CRAFTS CHANDELIER 4 GFCI M R R 3 GD DW 4 GFCI M R R 3 GD DW ELECTRICAL SCHEDULE 2D SYMBOL QTY DESCRIPTION COMMENTS A-5Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233ELECTRICAL LAYOUTTHIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES ELECTRICAL NOTES: 1.ELECTRICAL CONTRACTOR SHALL PROVIDE ARC-FAULT CIRCUIT INTERRUPTERS IN ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15 & 20 AMP OUTLETS IN LIVING ROOMS, DINING ROOMS, HALLWAYS, BEDROOMS, DENS, SUNROOMS, RECREATION ROOMS, CLOSETS, OR SIMILAR AREAS PER 2020 NEC 210.12(A) 2.ALL PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL COMPLY WITH THE MINIMUM REQUIREMENTS FOR HIGH- EFFICACY LAMPS PER FBC-ENERGY CONSERVATION R404 23-1017 DATE: AS NOTED 2ND FLOOR PLUMBING PLAN SCALE: 1/4" = 1'-0"1ST FLOOR PLUMBING PLAN SCALE: 1/4" = 1'-0" WH HB HB UPCWHC W H C W HCWC H / W H / WH / WH / WH / WH / WC / W C / W C / W C / W C / W C / W C / W C / W C / WC / WC / WC / WC / WC / WC / WC / WC / W CC / W WCC / Ww / Ww / Ww / Ww / Ww / Ww / Ww / W w / W w / W w / Ww / Ww / Ww / W w / W w / W w / WCL6'-1" CL 15'-5 3/4"CL 2'-6"CL1'-6"20'-6 1/4"FROM 2ND FLOOR HOSE BIBB 2 WAY C.O. HOSE BIBB SERVICE TO SANITARY MAIN DNHCW HCWHC W HC W HCWCWC Ww / Ww / Ww / W w / W w / W w / W w / Ww / WC / WC / WC / W C / W C / W C / WH / WH / W H / W H / W H / W H / WC / WC / WH / WH / WDROP TO 1STFLOOR H W C C w/W PLUMBING LEGEND: COLD WATER ACCESS HOT WATER ACCESS WASTE WATER ACCESS COLD WATER LINE HOT WATER LINE WASTE WATER C/ WH/ W A-6Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233PLUMBING PLANTHIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES PLUMBING NOTES: 1.ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE-RESIDENTIAL 7TH EDITION 2020. AND WITH ALL APPLICABLE REGULATIONS. 2.ALL HORIZONTAL SANITARY PIPING SHALL SLOPE AT 1-1/8" PER FOOT MINIMUM FOR 3' AND LARGER AND AT 1-1/4” SLOPE FOR 2-1/2” PIPES AND SMALLER 3.PLUMBING FIXTURES, FIXTURES SHALL BE AS SELECTED BY OWNER AND SHALL BE COMPLETE WITH DRAINS, TRAPS, SUPPLIES AND ANY OTHER ACCESSORY REQUIRED. FIXTURES AND FAUCETS SHALL COMPLY WITH THE FBC WATER SAVING STANDARDS. 4.MATERIALS: PIPING, UPONOR PEX PIPING OR PVC: A.      SOIL, WASTE AND VENT, AND STORM, SANITARY PIPE, PVC, DWV SCHEDULE 40 UNDER GROUND, AND Al30VE GROUND. B.       DOMESTIC WATER PVC PIPE AND FITTINGS INSIDE BUILDING WALLS, PVC OUTSIDE UNDER GROUND. C.      CONDENSATE DRAIN, DWC PVC PIPE AND FITTINGS. INSULATE ALL AB0VE GROUND CONDENSATE PIPING WITH 1-1/2” FOAM PLASTIC INSULATION WITH SOLVENT SEALED SEAMS. D.     DOMESTIC WATER SUPPLY ASSEMBLY, CHROME FINISH TUBING WITH ANGLE SHUT OFF VALVES. E.      P & T RELIEF LINES COPPER PIPE AND FITTINGS. F.       DRAIN PAN LINES, DWV PVC AND FITTINGS. 5. ALL AUTOMATIC ELECTRIC WATER HEATERS SHALL MEET THE STANDARDS OF THE LATEST ENERGY EFFICIENCY CODE. 6. VALVES, DOMESTIC WATER VALVES SHALL BE OF BRONZE B0DY, SWEAT ENDS. 7. HOSE BIBS, SHALL BE ¾” ROUGH BRASS CONSTRUCTION WITH SHUT OFF VALVE AND VACUUM BREAKER. 8. ALL OUTDOOR FLOOR CLEAN OUTS SHALL BE TERMINATED UP TO GRADE AND SHALL BE MARKED. 9. CLEANOUT5 SHALL BE PROVIDED AT THE BA5E OF EACH WASTE OR SOIL STACK. AS PER SECTION 108.3.4 FBCP 10. CONTRACTOR SHALL PROVIDE MAINTENANCE FREE MECHANICAL SHOCK ARRESTORS AT ALL FIXTURES WITH QUICK CLOSING VALVES. 11. VENT SYSTEM5 USING AIR ADMITTANCE VALVES SHALL COMPLY WITH THIS SECTION. INDIVIDUAL AND BRANCH-TYPE AIR ADMITTANCE VALVES SHALL CONFORM TO ASSE 1050. 12. THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM SHALL BE CONTROLLED TO REDUCE THE P055IBILITY OF WATER HAMMER A WATER HAMMER ARRESTOR SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS, WATER HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010. 13. BATHTUB, SHOWER AND WHIRLPOOL BATHTUB VALVES. THE HOT WATER SUPPLIED TO BATHTUB5 AND WHIRLPOOL BATHTUB5 SHALL BE LIMITED TO A MAXIMUM TEMPERATURE OF 120 F ( 49 C) BY A WATER-TEMPERATURE-LIMITING DEVICE THAT CONFORMS TO ASSE 1010, EXCEPT WHERE SUCH PROTECTION IS OTHERWISE PROVIDED BY A COMl3INATION TUB/SHOWER VALVE IN ACCORDANCE WITH SECTION P2708.3 ACCESS PANEL FOR WHIRLPOOL BATHTUB PUMP SHALL BE PROVIDED PER FBCR 2120.L 14. DISHWASHER CONNECTION. THE COMBINED DISCHARGE FROM A SINK DISHWASHER, AND WASTE GRINDER IS PERMITTED TO DISCHARGE THROUGH A SINGLE 1- ½”(38 MM) TRAP. THE DISCHARGE PIPE FROM THE DISHWASHER SHALL BE INCREASED TO A MINIMUM OF ¾”(9MM) IN DIAMETER AND SHALL CONNECT WITH A WYE FITTING BETWEEN THE DISCHARGE OF THE FOOD- WASTE GRINDER AND THE TRAP INLET OR TO THE HEAD OF THE FOOD GRINDER. THE DISHWASHER WASTE LINE SHALL RISE AND BE 5ECURELY FASTENED TO THE UNDERSIDE OF THE COUNTER BEFORE CONNECTING TO THE SINK TAIL PIECE OR THE FOOD GRINDER. 15. THE CONTRACTOR SHALL FIELD VERIFY ALL INVERT ELEVATIONS AND SIZE OF EXISTING SEWER AND WATER MAINS FOR CONNECTION OF NEW SERVICES. 16 - ALL PLUMBING FIXTURES SHALL BE DETERMINED BY OWNER 17- THESE DRAWINGS ONLY PROVIDE DESIGN LOCATIONS FOR THE EQUIVALENT DEPICTED HEREIN, THE PLUMBING CONTRACTOR SHALL OBTAIN SHOP DRAWINGS/ CUT SHEETS FROM THE EQUIVALENT SUPPLIER IN ORDER TO PLACE ROUGH-IN LINES AT OPTIMUM LOCATIONS FOR THE SPECIFIED EQUIPMENT. 18- THE PLUMBING CONTRACTOR SHALL PROVIDE FINAL CONNECTIONS TO ALL REQUIRED EQUIVALENT, UNLESS OTHERWISE NOTED. 19- NECESSARY, OBVIOUSLY REQUIRED PLUMBING ITEMS THAT ARE NOT SHOWN ON THESE DRAWINGS DOES NOT RELIEVE THE PLUMBING CONTRACTOR FROM THEIR RESPONSIBILITY OF INSTALLING A COMPLETELY OPERATING AND SAFE PLUMBING SYSTEM APPLICABLE w/ ALL CODES AS PREVIOUSLY DESCRIBED IN NOTE I ABOVE. 20-PIPE PROTECTION AS PER SECTION 305 FBCP ANY PIPE THAT PASSES UNDER A FOOTING OR THROUGH A FOUNDATION WALL SHALL BE PROVIDED WITH A RELIEVING ARCH, OR A PIPE SLEEVE PIPE SHALL BE BUILT INTO THE FOUNDATION WALL. THE SLEEVE SHALL 6E TWO PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH THE WALL PIPES PASSING THROUGH CONCRETE OR CINDER WALLS AND FLOORS OR OTHER CORROSIVE MATERIAL SHALL BE PROTECTED AGAINST EXTERNAL CORROSION BY A PROTECTIVE SHEATHING OR WRAPPING OR OTHER MEANS THAT WILL WITHSTAND ANY REACTION FROM THE LIME AND ACID OF CONCRETE, CINDER, OR OTHER CORROSIVE MATERIAL. SHEATHING OR WRAPPING SHALL ALLOW FOR MOVEMENT INCLUDING EXPANSION AND CONTRACTION OF FIFING MINIMUM WALL THICKNESS OF MATERIAL SHALL BE 0.010 INCH 23-1017 DATE: AS NOTED DUPONT TM R DUPONT TM R DUPONT TM R DUPONT TM DUPONT R TM R DUPONT TM R DUPONT TM R DUPONT TM R DUPONT TM R DUPONT TM DUPONT R TM R DUPONT TM R DUPONT TM R DUPONT DUPONT TM R DUPONT TM R TM R DUPONT TM R DUPONT TM R DUPONT TM R DUPONT TM R DUPONT DUPONT TM R TM R DUPONT TM R DUPONT TM R DUPONT TM R DUPONT TM R 8" (MIN.) TYVEKR TYVEKR TYVEKR TYVEKR Dupont™FlexWrap™ NF Dupont™FlexWrap™ NF TYVEKR TYVEKR TYVEKR Dupont™FlexWrap™ NF TYVEKR TYVEKR TYVEKR TYVEKR Dupont™FlexWrap™ NF TYVEKR TYVEKR TYVEKR TYVEKR TYVEKR TYVEKR Dupont™FlexWrap™ NF Dupont™FlexWrap™ NF 5'-1 3/4" Dupont™FlexWrap™ NF Dupont™FlexWrap™ NF Dupont™FlexWrap™ NF Dupont™FlexWrap™ NF 5 " (M IN .)TYVEKR9 7/16"7 1/4"13/16"12"6"1'-1 11/16"1'-6 5/8"4 1/4"5" (MIN.)7" (MIN.)7" (MIN.)5" (MIN.)1-1/2" (MIN.)5" (MIN.)1-1/2" (MIN.)TYPICAL WALLWOOD SIDINGWOOD FURRINGTYVEK HOMEWRAP7/16" PLYWOOD SHEATHING2"x4" WOOD STUDS w/ R13 BATT INSULATION 1/2" GYPSUM BOARD LAP AND TAPE TYVEKAT JOINTS WEATHER BARRIER ROOFING EXTEN DTYVEKâ HEADER WRAPâ AT TOP PLATE OVER SHEATHING TAPE TYVEK AT JOINTS ROOFING SHINGLESMEMBRANE TYPE EAVEPROTECTION (48" HIGH MIN.)ROOF SHEATHING c/w H CLIPS2"x2" WOOD FURRINGS 1/2" PLYWOODWOOD ROOF RAFTERSBATT INSULATION CEILING JOISTS1/2" GYPSUM BOARD VALLEY SHINGLE INSTALLATION:INSTALL SHINGLES USING WEAVE METHOD1. EXTEND (1) FULL END SHINGLE MIN. 12" PASTCENTER LINE OF VALLEY. SEE MANUFWRITTENINSTRUCTION FOR ADDITIONAL INSTALLATIONINFORMATION2. DO NOT NAIL 6" MIN. FROM VALLEY CENTER LINE FIBERGLASS SHINGLE ROOFINGOVERUNDERLAYMENTINSTALL SHINGLES OVER OFF-RIDGE VENT FLANGE ATHEADGALVANIZED METAL OFF-RIDGE VENT WITH BAFFLE. SET INPLASTIC ROOF CEMENT ORSEALANT SCREEN INSTALL OFF-RIDGEFIBERGLASSSHINGLEROOFING OVER 15# FELTOVER 7/16" OSBOVERPRE-ENG WD TRUSSESCUT PLYWOOD TO ALLOW FOR VENTILATION BETWEEN WOOD FURRINGS UNDER LAYME N T 1/2" GYPSUM BOARD(SEAL ALL JOINTS& PENETRATIONS)CAULK TYVEKÒ TOGYPSUM BOARD J- TRIM EAVESTROUG H TYPICAL WALL ISOMETRIC RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) WINDOW WITHINTEGRAL MOUNTING FLANG EMINIMALLY EXPANDINGPOLYURETHANE FOAM OR APPROVED CAULK(AROUND WINDOW RSO) WRAP TYVEK INTOOPENING & TAPE TO SILL (ESP. @ CORNERS)USING TYVEK FLEXWRAPLAP & TAPE TYVEKAT JOINTS (UPPER SHEET OVER LOWER SHEET)FASTEN TYVEK FLEXWRAPCORNER USING MECHANICAL FASTENER INSTALL TYVEK FLEXWRAPAROUND PERIMETER OF OPENING WINDOW HEAD DETAIL RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) WINDOW SILL DETAIL RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) CAULKIN G TYPICAL WALLWOOD SIDINGWOOD FURRINGTYVEK HOMEWRAP7/16" PLYWOOD SHEATHING2"x4" WOOD STUDS w/ R-13 BATT INSULATION 1/2" GYPSUM BOARD MINIMALLY EXPANDINGPOLYURETHANE FOAM OR APPROVED CAULK(AROUND WINDOW RSO)WINDOW WITHINTEGRAL MOUNTING FLANG E PLACE SHINGLES CLOSETOGETHER BUT DO NOT CROWD ALONG RAKES,CEMENTSHINGLES TO UNDERLAYMENT& EACH OTHER IN A 4" WIDTHOF ASPHALT PLASTIC ROOFCEMENT NON-CORRODING MTL EAVE DRIP PLACE SHINGLES3/8"OVER EAVE & RAKEEDGES TO PROVIDE DRIPEDG E FIRST COURSE APPROVED SEALANT.USECLOSED CELL BACKER ROD, IFGAP GREATER THAN 1/4" OPTIONAL BACKDAMDETAIL WHEN USING 9" WIDEDUPONT™FLEXWRAP™NF PEEL LARGEST STRIP OF RELEASE PAPERFIRST. FLASHINGS FOR WINDOWS 8" DUPONT™TYVEK ®/TAPE EXTERIOR INTERIOR DOOR DRIP EDGEFLASHIN G TYPICAL WALLWOOD SIDINGWOOD FURRINGTYVEK HOMEWRAP7/16" PLYWOOD SHEATHING2"x4" WOOD STUDS w/ R-13 BATT INSULATION1/2" GYPSUM BOARD INSTALL TYVEK FLEXWRAPOVER MOUNTING FLANGE. LAPTYVEK & TAPE JOINTS. PLACE SHINGLES3/8"OVER EAVE &RAKEEDGES TO PROVIDEDRIPEDG EALONG RAKES,CEMENTSHINGLES TO UNDERLAYMENT& EACH OTHER IN A 4" WIDTHOF ASPHALT PLASTIC ROOF CEMENT NON-CORRODING MTL EAVEDRIPTRIM 6"-7" FROM END OF FIRST SHINGLE TRIM TABS FROM ALLSTARTER COURSESHINGLES STARTER COURSE NOTES:1. INSTALL IN STRICT ACCORDANCE WITHMANUFACTURERS WRITTEN INSTRUCTIONS2. APPLY ROOFING CEMENT OR SELF- ADHERINGFLASHING OVER FLANGE AT HEAD ONLY FELT UNDERLAYMENT SHINGLEROOFINGMTL DRIP EDGE FASCI A TYPICAL WALLWOOD SIDINGWOOD FURRINGTYVEKâ HOMEWRAP7/16" PLYWOOD SHEATHING2"x4" WOOD STUDS w/ R-13 BATT INSULATION 1/2" GYPSUM BOARDROOF/ WALL INTERFACE DETAIL RESIDENTIAL WOOD FRAME STRUCTURE w/ WOOD SIDING (COOLING CLIMATE) VENTED SOFFIT FASCI A 11-1/2" to 12-1/2" 1" to 1-1/2" 11-1/2" to 12-1/2" 1" to 1-1/2"VALLEY FLASHING DETAILN.T.S. NOTES: 1. INSTALL IN STRICT ACCORDANCE WITHMANUFACTURERS WRITTEN INSTRUCTIONS2. APPLY ROOFING CEMENT OR SELF-ADHERINGFLASHING OVER FLANGE AT HEADONLY ROOF CEMENT 24" WIDE METAL VALLEYFLASHING OVER 15# FELT VENT FLANGEOVERSHINGLES ATBASE7/16" OSBOVERPRE-ENGWDTRUSSES WALL SHEATHING SYN WD SIDING OVERAPPROVED WEATHERBARRIE RLAP WEATHER BARRIEROVERMETAL FLASHING AND SECURE WITH STARTER STRIP EXTEND 15# ROOFING FELTUP WALL 7" MIN. 5x5 METAL FLASHING OVER ROOFING FELT (NAIL TO ROOFDECK NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAIL INSTALL WITH ROOF CEMENT SHINGLE ROOFING OFF-RIDGE VENT FLASHING DETAIL N.T.S.WALL FLASHING DETAIL - LAP SIDINGN.T.S. WALL SHEATHING SHINGLE NAILINGNOTE: DETAILS ARE FOR SLOPES OF 3:12 OR GREATER,FOR SLOPES BELOW 3:12, ALL ROOFING UNDERLAYMENTSHALL BE SELF ADHERING SHEET MEMBRANE APPROVEDBY THE SHINGLE MANUFACTURER FOR USE ON LOWSLOPE ROOFING PROJECTS INSTALL SHINGLES OVERFLANGE @ HEAD OPT. PROVIDE LEAD VENTBOOT WITH INTEGRAL FLANGE VENT STACK, SEE PLUMBINGFOR SIZE &LOCATIONPREFORMED FLEXIBLEBOOTFLASHING W/ INTEGRAL FLANGESET IN PLASTIC ROOF CEMENT INSTALL FLANGE OVER SHINGLE @BASE VINYL DRIP/WEEP SCREED 5"x5" METAL FLASHING KICK-OUT FLASHING (SEEDETAIL) EXTEND KICK-OUT 2"BEYONDFASCIA WALL FLASHING DETAIL - STUCCO N.T.S. FLASHINGS FOR DOORS NOTE: INSTALL KICKOUTFLASHING AT BOTTOM OFROOF & WALL INTERSECTIONS VENT STACK FLASHING DETAIL N.T.S. WALL/KICKOUT FLASHING DETAIL N.T.S. WATER TIGHT SEA L OSB OR SIMILARSHEATHING SECONDAR YWEATHER BARRIERFIBER CEMENTBOARD ORSIMILA R CLOSING BEAD ROOF CEMENT FIBERGLASS SHINGLEROOFING OVER 15# FELTOVER 7/16" OSBOVERPRE-ENG WDTRUSSES STUCCO/CV FINISH ASSEMBL Y LAP BARRIER OVER NAILINGFLANG E STUCCO/CV FINISHASSEMBLY W/ 15#FELTOVER APPROVED WEATHERBARRIE RLAP FELT AND WEATHER BARRIER OVER VINYLSTUCCO STOP/ WEEPEXTEND 15# ROOFING FELTUP WALL 7" MIN. 5x5 METAL FLASHING OVER ROOFING FELT (NAIL TOROOF DECK NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAILINSTALL WITH ROOFCEMENT SHINGLEROOFING DOOR HEAD NOGAPSINCORNERS OSB OR SIMILARSHEATHING SECONDAR YWEATHE RBARRIE RCORRECTINCORRECT STEP 8 A.INSTALL THE SILL FLASHING.REMOVE THE LARGEST STRIP OF RELEASE PAPER,ALIG NTHE FLASHING WITH THE INTERIOR EDGE OFSILL AND INSTALL INTO ROUGH OPENING ACROSS SILL AND UP JAMBS (6"MIN.).B . APPLY WORKING FROM THEMIDDLE OF THE SILL TOWARDS THE SIDES. SECURE DUPONT™ FLEXWRAP™ NF TIGHTLY INTOTHE CORNERS BY FIRST WORKING INALON GTHE SILL BEFORE ADHERING UP THE JAMBS .C. DO NOT STRETCH MATERIAL ALONG THE SILL ORJAMBS. STEP 7 A . PREPARE THE SILL FLASHING BYCUTTING A PIECE OF DUPONT™ FLEXWRAP™ NFTHAT IS AT LEAST 12" LONGER THAN THE SILLLENGTH. B. USE 6" DUPONT™ FLEXWRAP™NF FOR 2"x 4" FRAMING AND 9" DUPONT™ FLEXWRAP™ NFFOR 2"x 6" FRAMING. C. STEP 6 A . FLIP THE CUT HEAD FLAP UPWARD TO EXPOSE THE SHEATHINGANDTEMPORARILY SECURE WITH DUPONT™TYVEK ®/ TAPE. INSPECT INSTALLATION SURFACETO ENSURE THE SURFACE IS FREE OF DIRT AND SUBSTANCES THAT COULD INTERFERE WITH ADHESION AS WELL AS ANYSHARPPROTRUSIONS. STEP 5 A . STEP 4 FOLD SIDE FLAPS INTO ROUGH OPENING AND SECURE TOINSIDEWALL .SECURE TO INSIDE WALL WITH TYVEK ®/TAPE OR DUPONT™ TYVEK®/ WRAP CAPFASTENERS A. CUT AN "I-CUT" (STANDARD I- CUT) INTHE DUPONT™ TYVEK ®/ WRB.B. CUT A HEAD FLAP AT A 45 ANGLE TOEXPOSE 8" OF SHEATHING TO ALLOW FOR HEAD FLASHING INSTALLATION. STEP 3 A. DUPONT™ TYVEK ®/ WRB TO BEMECHANICALLY FASTENED ANDINSTALLED OVERSHEATHING.B. DO NOT INSTALL FASTENERS WITHIN 6" OF THE SILLS AND JAMBS OF THE OPENING SAND WITHIN 9" OF THE HEAD OPENINGS . STEP 2 A.BAR ESTUDS. B . STEP 1 SHEATHING TO BE INSTALLED OVER AFTER SHEATHING HAS BEENINSTALLED, CUTAN OPENING IN THE SHEATHINGALONGTHE PERIMETER OF THE ROUGH OPENING FOR WINDOW .C. ENSURE THE SHEATHING IS CUT FLUSH WITH OR SLIGHTLY BELOW THE SILL FRAMINGTOALLOW FOR POSITIVE DRAINAGE. BARE STUDS PRIOR TO SHEATHING INSTALLATION. SLOPE SILL FRAMING TO EXTERIOR.FRAMING AND NON-WATERPROOFING COMPONENTS ARE ONLYSHOWN SCHEMATICALLY. SEE DRAWINGSB YOTHERS FOR DETAILED INFORMATION. INTERIOR APPROVED SEALANT.USECLOSED CELL BACKER ROD,I FGAP GREATER THAN 1/4" GRID EXTERIOR FRAMED WALL BEYONDDOOR FRAME PER SCHEDULEFLOOR SLAB ASSEMBLY PERPLAN AND SECTIONS ALUMINIUM THRESHOLD SET IN CONTINUOUS BED OF BUTYLSEALANT CONCRETE SLAB. SEE PLANS DOOR THRESHOLD CORRECTDUPONT™ FLASHING TAPEOVERLAPSDUPONT™ FLEXWRAP™ NF EXPANSION JOINTMATERIAL FIBER CEMENTBOARD ORSIMILA RDOOR JAMB CLOSING BEAD INCORRECTDUPONT™ FLASHING TAPE FLUSHWITHDUPONT™ FLEXWRAP™ NF INCORRECTDUPONT™ FLEXWRAP™ NFREVERSEFLASHED STEP 17 A . INSTALL DUPONT™ RESIDENTIAL STEP 16 A .SEALANT OR RECOMMENDED SEALANT (ANDBACKER ROD ASNECESSARY) AROUND THE WINDOWOPENING AT THE INTERIOR. IT IS ALSO ACCEPTABLE TO USE DUPONT™ WINDOW AND DOOR FOAM ORRECOMMENDED FOAM ATTHE INTERIOR CAVITY OF THE JAMBSAND HEAD. IF FOAMIS USED AT THE SILL, RECOMMENDEDSEALANT SHOULD BE USED AT THE SILL AREA BEHINDTHE FOAM TO ENSURE A PROPER WATER SEAL. TAPE ALL CUTS IN DUPONT™ TYVEK ®/WRB ANDTAPEACROSS HEAD OF THE WINDOWWITH DUPONT(TM) TYVEK(R) TAPE, 4" DUPONT™FLASHING TAPE ORDUPONT™ STRAIGHTFLASH™. STEP 15 A.TRIM THE DUPONT™ TYVEK ®/WRB 1"-2" ABOVE THE WINDOW OPENING.B. WHEN TRIMMING THE DUPONT™ TYVEK ®/WRB, DO NOT CUT OR DAMAGETHE HEADFLASHING THAT HAS BEEN INSTALLED BEHIND IT. STEP 14 A . FLIP DOWN UPPER FLAP OFDUPONT™ TYVEK ®/ WRB SO IT LAYS FLAT ACROSSTHE HEAD FLASHING. A. CUT A PIECE OF DUPONT™ STRAIGHTFLASH™, DUPONT™FLASHIN GTAPE FOR HEAD FLASHING,B. HEAD FLASHING TO EXTEND BEYON DOUTER EDGES OF JAMBFLASHING.C. REMOVE RELEASE PAPER ANDINSTALL COMPLETELY COVERING WINDOWMOUNTING FLANGE AND ADHERING TO THE EXPOSED SHEATHING. STEP 12 A. CUT TWO PIECES OF DUPONT™ FLASHING TAPE OR DUPONT™STRAIGHTFLASH™ FOR JAMB FLASHIN GEXTENDING 1" ABOVE WINDOW HEADFLANGE AND 4" TO 6" BELOW BOTTOM EDGE OF SILLFLASHING.B. REMOVE RELEASE PAPER ANDPRES STIGHTLY ALONG SIDES OF WINDOWFRAME . STEP 11 A . STEP 10 A . INSTALL WINDOW ACCORDING TO MANUFACTURER'S INSTALLATIONINSTRUCTIONS. APPLY(CONTINUOUSLY)DUPONT™ RESIDENTIAL SEALANT OR RECOMMENDED SEALANT ON THE HEAD AND JAMBS OF ROUGH OPENING (ON TOP OFWRB).B.IF SEALANT IS APPLIED TO THE SILL,ENSURE THAT THERE ARE AT LEAST TWO (2) 2" INCH GAPS IN THE SEALANT BEADFOR EVERY 4' OF WINDOW TO ALLOW FORDRAINAGE . A. REMOVE NARROW PIECE OF THERELEAS EPAPER .B . FAN DUPONT™ FLEXWRAP™ NF AT BOTTOM CORNERS AND ADHERE ONTOEXTERIOR FACE OF WALL. COVERAGE SHOULD BE2" TO 3" INCHES ONTO THE FACE OF THE WALL C. PRESS SILL FLASHING W/ FIRMHAND .PRESSURE OR J-ROLLER TO ENSURE FULL ADHESION ON ALL SURFACES STEP 13 STEP 9 SEALANT SEALANT 1 2" 1 2"6 "E A V EDRIP E D G E 6 "6 "6 "S U C C E EDI N G C O U R S E S ID EL AP2 " ROO F D ECK E N D L AP6 " U N D ERL AY M ENT R AK E D R I P E D G E 2 "110°A-7Revision TableNumberDateRevised ByDescriptionSHEET: SCALE: PROJ. # 2/16/2024MARTIN ENGINEERING, LLC450 STATE ROAD 13 N., #106-387JACKSONVILLE, FL 32259 FL CA: 32027NEW SINGLE FAMILY808 AMBERJACK LANEATLANTIC BEACH, FL 32233FLASHING DETAILSTHIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE (#80359) ON 2/16/24 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES 23-1017 DATE: AS NOTED S-1STRUCTURAL NOTESSHEET INDEXS-1S-2STRUCTURAL DETAILSFOUNDATION PLAN,STRUCTURAL NOTES & SPECIFICATIONSS-3S-4 THRU S-6FRAMING PLAN & DETAILS555544aaaahWALLSSYMBOL LEGEND1S-11S-1VIEW DIRECTIONLOCATION OFSECTION CUTSHEET No. WHERESECTION IS LOCATED.DETAIL/SECTION NUMBERSHEET No. WHERESECTION IS LOCATED.VIEW DIRECTIONDETAIL/SECTION NUMBERA1S-1DETAIL/SECTION NUMBERSHEET No. WHERESECTION IS LOCATED.WALL SECTIONELEVATIONDETAILCALL OUTCUT/ MATCH LINEELEVATION DATUMXSLAB STEP(INCHES)ZONE CHARTSABBREVIATIONSU.N.O.UNLESS OTHERWISE NOTEDEORSYPSPFO.C.LVLw/w/oOR"OR" MEANS THAT EITHER OPTION PROVIDED IS SUFFICE FOR THE APPLICATIONFBCMAX.MIN.OSBPLYW.PSIPSFPCFTYPSSW.W.M/FSWINT.EXT.CLCLGCMULGFTGOPTDLLLBMCONT.FFEWITHWITHOUTWELDED WIRE MESH OR FABRICTYPICALSHEAR WALLSOUTHERN YELLOW PINE (No. 2 MIN.)SPRUCE-PINE-FIRSTAINLESS STEELPOUNDS PER SQUARE INCHPOUNDS PER SQUARE FEETPLYWOOD (APA RATED MIN.)POUNDS PER SQUARE FEETORIENTED STAND BOARD (APA RATED MIN.)OPTIONALON CENTER SPACINGMINIMUMMAXIMUMLAMINATED VENEER LUMBER (2.0E, 1 34" WIDE MIN. U.N.O.)LIVE LOADLENGTHINTERIORFOOTINGFINISHED FLOOR ELEVATIONFLORIDA BUILDING CODE (2023, 8TH EDITION)EXTERIORENGINEER OF RECORDDEAD LOADCONCRETE MASONRY UNITCEILINGCENTER LINECONTINUOUSBEAMFPAFLORIDA PRODUCT APPROVALB/TBETWEENCONN.CONNECTIONT/GT&GTOGETHERTONGUE AND GROOVESTAGG.STAGGEREDGENERAL STRUCTURAL NOTESTHE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCINGWORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THEENGINEER PRIOR TO COMMENCING WORK.DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO SIMILAR SITUATIONSELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF DETAILS, SECTIONS, PLANS, ANDNOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR.DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLEDATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATAINVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OROTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK ISPERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OFAPPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TOEXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATIONBY THE OWNER.CENTER ALL FOOTINGS AND PIERS UNDER COLUMNS ABOVE UNLESS SPECIFICALLY DIMENSIONED OTHERWISE.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL,MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES,DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.CONTRACTOR SHALL LOCATE ALL BURIED UTILITIES PRIOR TO EXCAVATION FOR BUILDING FOUNDATIONS. THESTRUCTURAL ENGINEER SHALL BE NOTIFIED OF POTENTIAL CONFLICTS BETWEEN FOUNDATIONS AND BURIEDUTILITIES.CODE REQUIREMENTS:THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2023 FLORIDA BUILDING CODE, 8TH EDITION.OTHER CODES IMPLEMENTED FOR DESIGN INCLUDE:ASCE7-16, ACI 315/318/530, NDS 2018, APA, A.I.S.C., ANSI. FOLLOW ALL APPLICABLE PROVISIONS OF THE FLORIDABUILDING CODE AND OTHER RELATED CODES FOR ALL PHASES OF CONSTRUCTION.TEMPORARY CONDITIONS:THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS ON INTERACTION OF VARIOUSCONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS ASREQUIRED TO SAFELY COMPLETE THE WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNEDFOR STABILITY UNDER FINAL CONFIGURATION ONLY.FOUNDATIONS:FOUNDATIONS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF ON COMPACTED FILL.NO GEOTECHNICAL REPORTS AND/OR IN-SITU SOIL DATA WAS GIVEN TO THE STRUCTURAL ENGINEER PRIOR TODESIGN. THE BEARING CAPACITY USED FOR DESIGN IS BASED ON ALLOWABLE LOADS FROM THE 2023 FLORIDABUILDING CODE, 8TH EDITION, FOR SANDY SOILS WITH NO CLAY, ORGANIC MATERIAL, OR OTHER DELETERIOUSMATERIALS THAT WOULD AFFECT DESIGN BEARING PRESSURE AND THE PERFORMANCE OF THE FOUNDATIONS.BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACEINVESTIGATION,AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY,WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION IN ORDER TO BEARTHE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEWBEFORE FOUNDATION CONSTRUCTION BEGINS.CONCRETE:REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE FBC AND ACI 318 "BUILDING CODEREQUIREMENTS FOR REINFORCED CONCRETE". CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD28-DAY CYLINDER TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS:f'cABS W/CMIN CEMENTSLUMPUSE2,500 PSI0.58470 LBS5” +/- 1ALL SLABS, MONOLITHIC FOOTINGS, SPREAD FTG3,000 PSI0.58470 LBS5” +/- 1TIEBEAMS, COLUMNS, WALLS, ELEVATED SLABSCEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM C618, TYPE F OR TYPE C, MAYBE USED TO REPLACE UP TO 20% OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH ISSUBSTANTIATED BY TEST DATA. COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING TO ASTM C33.A WATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT ACCORDANCE WITH THEMANUFACTURER'S RECOMMENDATIONS, SHALL BE INCORPORATED IN CONCRETE DESIGN MIXES. A HIGH-RANGEWATER-REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES,PROVIDING THAT THE SLUMP DOES NOT EXCEED 8”.SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGSSHALL BE APPROVED BY THE STRUCTURAL ENGINEER BEFORE POURING. NO SLEEVE, OPENING, OR INSERT MAYBE PLACED IN BEAMS, JOISTS, OR COLUMNS UNLESS APPROVED BY THE ENGINEER. CONDUITS EMBEDDED INSLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB ANDSHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER.PROVIDE 3/4” CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. WHERE INDICATEDOR REQUIRED, SLOPE CONCRETE SLABS TO DRAINS SHOWN ON PLUMBING AND/OR ARCHITECTURAL DRAWINGS.ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OPERATIONS.WEATHER RESISTANCE:ALL CONCRETE INCLUDING BALCONY CONCRETE EXPOSED TO CHLORIDES SHALL CONTAIN A CALCIUM-NITRITEBASED CORROSION-INHIBITING ADMIXTURE. THE DOSAGE FOR CONCRETE EXPOSED TO AIRBORNE CHLORIDESSHALL BE MINIMUM TWO GALLONS PER CUBIC YARD. THE WATER CONTAINED IN THE CORROSION-INHIBITINGADMIXTURE SHALL BE USED IN THE CALCULATION OF THE WATER-TO-CEMENTITIOUS RATIO OF THE CONCRETE.PROVIDE RHEOCRETE CNI BY MASTER BUILDERS OR APPROVED EQUIVALENT.CONCRETE BALCONIES OR OTHER CONCRETE FLAT SURFACES EXPOSED TO THE WEATHER THROUGHOUT THELIFE OF THE BUILDING, SHALL BE TREATED WITH A CLEAR NONFLAMMABLE PENETRATING SEALER OF THEALKYL_ALKOXY SILANE CLASSIFICATION, SUCH AS SONNEBORN PENETRATING SEALER 20, HYDROZO ENVIROSEAL20, OR OTHER APPROVED WEATHER RESISTANT SYSTEM. APPLICATION AND SURFACE PREPARATION SHALL BE INACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.SHORING AND RESHORING:SHORING AND RESHORING SHALL CONFORM TO ACI 347R-88. SHORING AND SUPPORTING FORMWORK SHALL NOTBE REMOVED FROM HORIZONTAL MEMBERS BEFORE CONCRETE STRENGTH IS AT LEAST 70 PERCENT OF DESIGNSTRENGTH, AS DETERMINED BY FIELD CURE CYLINDERS. IN ADDITION, SHORING SHALL NOT BE REMOVEDSOONER THAN RECOMMENDED BY ACI 347R-88, SECTION 3.7.2.3. FORMWORK SHALL NOT BE REMOVED IN LESSTHAN TEN (10) DAYS.PRECAST CONCRETE LINTELS:UNLESS INDICATED OTHERWISE, ALL LINTELS TO BE "U" TYPE PRECAST CONCRETE UNITS EQUAL TO UNITSMANUFACTURED BY CAST_CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS REQUIRED) INACCORDANCE WITH CAST CRETE CORP. ''DESIGN MANUAL", LATEST EDITION, FOR THE SPAN AND LOADINGCONDITION RELATIVE TO LINTEL LOCATION. LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8-1B FOROPENINGS LESS THAN 10 FEET AND 8F16-1B/1T FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" MINIMUM BEARINGFOR LINTELS UNLESS NOTED OTHERWISE.WOOD:SAWN LUMBER SHALL BE SOUTHERN PINE #2 WITH THE ALLOWABLE FIBER STRESSES PER THE AWC NATIONALDESIGN SPECIFICATION. ALL MANUFACTURED LUMBER SHALL BE 2.0E GLUED LAMINATED GEORGIA PACIFIC (OREQUIV.) AND INSTALLED ACCORDING TO MANUFACTURES RECOMMENDATIONS. ALL HEADERS/BEAMS SHOULDBEAR FULLY ON POSTS AND/OR MULTI STUD GROUPS UNLESS NOTED OTHERWISE ON PLANS. CONTACT ENGINEEROF RECORD IF HEADER/BEAMS SIZE IS NOT SPECIFIED.FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON COMPANY OR USP(OR APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HANGERS NOT SHOWN SHALL BESIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL CONNECTORS SHALL BE GALVANIZED. UNLESS SHOWNOTHERWISE, INSTALL MAXIMUM SIZE AND NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOGALL FRAMING NAILS SHALL BE COMMON NAILS AND SHALL BE OF THE SIZE AND NUMBER INDICATED ON THEDRAWINGS. MINIMUM NAILING REQ. NOT SHOWN SHALL BE AS INDICATED IN TABLE 2304.9.1 OF THE FBC. INSTALL10d NAILS UNLESS OTHERWISE SPECIFIED ON THE PLANS OR DETAILS. BOLTS AND LAG SCREWS SHALL CONFORMTO ANSI/ASME STANDARD B18.1. ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUTWASHERS.ALL ANCHOR BOLTS AND THREADED ANCHOR RODS SHALL BE IN ACCORDANCE WITH ASTM A307, GRADE A, ORASTM F1554, GRADE 36. ANCHOR ADHESIVES SHALL BE EITHER SET (EPOXY-TIE) OR AT (ARCYLIC-TIE) BY SIMPSONSTRONG-TIE AND INSTALLED ACCORDING TO THE MANUFACTURES INSTRUCTIONS. ALL DRILLED ANCHOR HOLESSHALL BE CLEANED OF ALL DEBRIS AND BRUSHED OUT PRIOR TO INSTALLATION OF ANCHOR ADHESIVE.ALL WOOD MEMBERS EXPOSED TO EXTERIOR CONCRETE, MASONRY, WEATHER, OR EARTH SHALL BE PRESSURETREATED LUMBER. ALL NAILS DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED. FASTENERREQUIREMENTS IN PRESSURE TREATED LUMBER ARE AS FOLLOWS:ACZA PRESERVATIVE: STANDARD CARBON STEEL.ACQ & MCQ PRESERVATIVE: HOT DIPPED GALVANIZED.SODIUM BORATE: STAINLESS STEEL CONNECTORS & FASTENERS (NOT REQ. FOR SILL PLATES OVER CONCR. & VAPOR BARRIER NOT DIRECTLY EXPOSED TO EARTH OR WEATHER)ALL DECKS, GUARDS, RAILS, STAIRS AND OTHER ACCESSORY DECK COMPONENTS SHALL BE CONSTRUCTED INACCORDANCE WITH AWC DCA6 PRESCRIPTIVE GUIDE FOR DECK CONSTRUCTION & THE 2023 FLORIDA BUILDINGCODE, 8TH EDITION. ALL FASTENERS AND CONNECTORS EXPOSED TO SALT WATER OR LOCATED WITHIN 300 FEETOF A SALT WATER SHORE LINE SHALL BE STAINLESS STEEL GRADE 304 OR 316ALL EXTERIOR WOOD WALLS WITHOUT OPENINGS SHALL BE CONSIDERED SHEAR WALLS. ALL WOOD DESIGNSHALL BE IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2015 & WITHTHE FLORIDA BUILDING CODE, 2023.PLYWOOD PANELS SHALL CONFORM TO THE REQUIREMENTS OF “U.S. PRODUCT STANDARD PS-1 FORCONSTRUCTION AND INDUSTRIAL PLYWOOD” OR APA PRP-108 PERFORMANCE STANDARDS. UNLESS OTHERWISENOTED, PANELS SHALL BE APA RATED SHEATHING, EXPOSURE 1, OF THE THICKNESS AND SPAN RATING SHOWNON THE DRAWINGS.PLYWOOD INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW 1/8” SPACING ATPANEL EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER.ALL SUB-FLOORING, ROOF, AND SHEARWALL SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULARTO SUPPORTS, EXCEPT AS INDICATED ON THE DRAWINGS. STAGGER ENDS OF ADJACENT PANELS 4'-0".ROOF SHEATHING SHALL BE BLOCKED, TONGUE-AND-GROOVE, OR HAVE EDGES SUPPORTED BY PLYCLIPS.ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 10d NAILS SPACED 4" ON CENTER ALONG THE PANELEDGES AND AT 6" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE.SUB-FLOORING SHEATHING SHALL BE UNBLOCKED, EXCEPT AS INDICATED ON DRAWINGS. ATTACH PLYWOODPANELS TO SUPPORTING MEMBERS WITH 8d NAILS SPACED 4" ON CENTER ALONG THE PANEL EDGES AND AT 8" ONCENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE.PREFABRICATED WOOD TRUSSES:SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACTDOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THECONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. CONTRACTOR SHALL NOT BERELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SHOP DRAWINGS OR MIX DESIGNS BY THEENGINEER'S REVIEW.DESIGN AND MANUFACTURE IN ACCORDANCE WITH TPI "DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTEDWOOD TRUSSES", LATEST EDITION.ROOF TRUSS LOADING: SEE TRUSS MANUFACTURES SIGNED AND SEAL TRUSS SHOP DRAWINGS FOR APPLICABLETRUSS DESIGN LOADS. TRUSS LOADINGS SHALL BE BASED ON THE PROJECTS DESIGN LOADS AND THE MINIMUMLOAD REQUIREMENTS SET FORTH BY ASCE 7-10 AND THE FLORIDA BUILDING CODE, 2023 RESIDENTIAL.ALL TRUSS TO TRUSS CONNECTIONS TO BE DESIGNED BY TRUSS MANUFACTURER AND MADE USING TRUSSHANGERS. TRUSS DIAGRAMS, IF SHOWN, ARE DIAGRAMMATIC ONLY. TRUSS DESIGNER TO DETERMINE ANDESTABLISH EXACT HEIGHT, LENGTH, LOCATION, SPACING, AND WEB MEMBER FOR EACH TRUSS. COORDINATEWITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL ITEMS INCLUDING AIR HANDLER LOCATIONS,MECHANICAL ROOMS AND DUCT SPACE AND ROUTING.BUILDER SHALL COORDINATE WITH TRUSS DESIGNER FOR PERMANENT TRUSS BRACING. IF NO BRACINGINFORMATION IS PROVIDED, BOTTOM CHORD LATERAL BRACING SHALL BE CONTINUOUS FROM ONE END OF THEBUILDING TO THE OTHER AND SHOULD OVERLAP AT LEAST ONE TRUSS SPACE FOR CONTINUITY. LATERALBRACING SHALL BE NAILED TO EACH TRUSS WITH A MIN. OF (2) 16d NAILS INCLUDING INTERMEDIATE TRUSSES.SEE TRUSS SHOP DRAWINGS FOR OTHER DETAILS AND SPECIFICATIONS FOR BRACING.REINFORCING STEEL:REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, FOR DEFORMED BAR AND ASTM A185 FORSMOOTH WELDED WIRE FABRIC (WWF), UNLESS OTHERWISE NOTED. REINFORCING STEEL TO BE WELDED SHALLCONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRONWIRE.ALL DETAILING AND ACCESSORIES SHALL CONFORM TO ACI DETAILING MANUAL SP_66. PROVIDE CHAIRS,SPACERS, BOLSTERS, AND ITEMS IN CONTACT WITH FORMS WITH HOT_DIP GALVANIZED LEGS OR PLASTIC LEGS.ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT AGAINST DISPLACEMENT BY FORMWORKCONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. "WET-STICKING" OF REINFORCING IS PROHIBITED.REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NOTED OTHERWISE): FOOTINGS 3" BOTTOM AND SIDES, 2" TOPSLABS3/4"COLUMNS 1-1/2" TO TIES, 2" TOPBEAMS 1-1/2" TO STIRRUPSWALLS 1-1/2”LAP SPLICE CONTINUOUS VERTICAL OR HORIZONTAL BARS IN CONCRETE MEMBERS IN ACCORDANCE WITH ACI318, LATEST EDITION, FOR CLASS "B" TENSION LAP SPLICES. DO NOT SPLICE CONTINUOUS TOP BARS IN BEAMS ATENDS OF CLEAR SPANS. DO NOT SPLICE CONTINUOUS BOTTOM BARS IN BEAMS IN CLEAR SPANS BETWEENSUPPORTS. SHOW ALL SPLICES ON SHOP DRAWINGS. SPLICE LOCATIONS AND METHODS SUBJECT TO APPROVALOF STRUCTURAL ENGINEER.AT SLAB AND WALL OPENINGS PROVIDE A MINIMUM OF (2) #5 BARS ALL FOUR SIDES AND DIAGONALLY; EXTENDTHESE BARS A LAP DISTANCE OR A MINIMUM OF 24” PAST THE OPENING OR HOOK BARS IF DISCONTINUOUS.DOWEL ALL WALLS AND COLUMNS TO FOOTINGS WITH BAR SIZE AND SPACING TO MATCH VERTICAL REINFORCINGUNLESS OTHERWISE SHOWN.MASONRY WALLS:MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTHOF f'm= 1500. MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C270. GROUT SHALL BE 2000 PSI MINIMUMCOMPRESSIVE STRENGTH AT 28 DAYS IN ACCORDANCE WITH ASTM C476. GROUT SHALL CONSIST OF A MIXTUREOF CEMENTITIOUS MATERIALS AND AGGREGATE TO WHICH SUFFICIENT WATER HAS BEEN ADDED TO CAUSE THEMIXTURE TO FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. GROUT SHALL HAVE A MAX. COURSE AGGR.SIZE OF 38" & SHALL BE PLACE WITH A SLUMP OF 8 TO 11 INCHES. ALL CELLS CONTAINING VERTICAL BARS, BONDBEAMS, AND ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POURALLOWED IS 5'-0" UNLESS CLEAN-OUT OPENING IS PROVIDED AT BOTTOM OF CELLS TO BE FILLED. LOCATECLEAN-OUT OPENINGS IN AREAS NOT EXPOSED TO VIEW. CLEAN OUT OPENINGS SHALL HAVE A MIN, OPENINGDIMENSION OF 3 INCHES.UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BE PARTIALLY REINFORCED MASONRY WALLCONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT FILLED CELLS. ADD (1) #5 REINFORCING BAR EACH SIDE OFOPENINGS EXCEEDING 3 FEET.PROVIDE REINFORCING BARS AT CORNERS, INTERSECTIONS, AND EACH SIDE OF OPENINGS. PROVIDE (2)REINFORCING BARS EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AND AS SHOWN ON THE PLANS. PROVIDEHOOKED DOWELS INTO FOOTINGS AND STRUCTURE ABOVE AND/OR BELOW TO PROVIDE CONTINUITY. PROVIDE 9GAGE GALVANIZED HORIZONTAL JOINT REINFORCING (DUR-O-WAL OR ENGINEER-APPROVED EQUAL) AT 16” O.C.DO NOT PLACE CONDUITS, PIPES, ETC., IN CELLS WITH VERTICAL REINFORCING. DO NOT RUN CONDUITS, PIPES,ETC., HORIZONTALLY IN CMU WALLS PARALLEL TO LENGTH OF WALL. WHERE MASONRY WALLS ABUT CONCRETECOLUMNS TO BE PLACED PRIOR TO ERECTION OF MASONRY WALLS, PROVIDE DOVETAIL SLOTS BETWEEN COLUMNAND WALLS AND GROUT THE CMU CELL CONTAINING THE DOVETAIL ANCHORS. OTHERWISE, EXTEND CMUHORIZONTAL JOINT REINFORCING THROUGH CONCRETE COLUMN.CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY CONSTRUCTION AT LOCATIONS INDICATED ONTHE ARCHITECTURAL DRAWINGS. HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROLJOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT CONTROL JOINTS.USE METAL LATH OR WIRE SCREEN FOR CAVITY CAPS. SHEET METAL, FELT, BUILDING PAPER, OR LIKE MATERIALSARE PROHIBITED. BRICK VENEER TIES SHALL BE NO. 9 U.S. GAUGE WIRE OR NO. 22 U.S. GAGE x 7/8” CORRUGATED METAL AND SHALL HAVE A HOOK EMBEDDED INTO THE MORTAR JOINT. TIES SHALL BE PLACED WITHIN 12” OF ALL WALL OPENINGS AND SHALL BE SPACED AT NO MORE THAN 18” O.C. HORIZONTALLY AND VERTICALLY ATTACHED THROUGH THE SHEATHING TO THE WALL STUDS. STEEL LINTELS OVER OPENINGS SUPPORTING BRICK VENEER TOBE IN ACCORDANCE WITH THE TABLE BELOW AND R703.8.3DESIGN CRITERIA:DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA OF THE 2023 FLORIDA BUILDINGCODE 8TH EDITION. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS ANDALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER THE 2023 FBC:LIVE LOADDEAD LOADDEFLECTIONROOF:20 PSF10 PSFL/240 - L/180CEILING:10 PSF5 PSFL/240 - L/180FLOOR:40 PSF15 PSFL/360 - L/240DECK:50 PSF15 PSFL/360 - L/240WALLS:PER WIND CHARTASCE7-22 TBLE. C3-1L/240 - BRITTLEL180 - FLEXIBLEULTIMATE WIND SPEED 130 MPH PER ASCE 7-22NOMINAL WIND SPEED: 101 MPH PER FBC R301.2.1.3EXPOSURE C PER ASCE 7-22IMPORTANCE FACTOR1.0CATEGORY IIINTERNAL PRESSURE COEFF+/- 0.18ENCLOSED (PROTECTED OPENINGS)COMPONENTS & CLADDING PRESSURES PER TABLE & CHARTS ON THIS PAGE.WIND BORNE DEBRIS REGIONNOWIND PRESSURES ON WALLS & ROOFS 3SIMPSON CONNECTOR SCHEDULECLIPS, STRAPS, OR TIESFASTENERSA34(8) 8d X 1.5" NAILS TOTAL (FILL ALL HOLES)A35(12) 8d X 1.5" NAILS TOTAL (FILL ALL HOLES)AC4/6(14) 16d X 3.5" NAILS IN POST & BEAM (28 TOTAL)BC4(6) 16d X 3.5" NAILS IN EACH FLANGE (12 TOTAL)BC46(6) 16d X 3.5" IN POST FLANGE, (1) 16d IN BEAM FLANGE (18 TOTAL)BC6(12) 16d X 3.5" NAILS IN EACH FLANGE (24 TOTAL)CS14SYP: (30) 8d X 2.5"(16" END LENGTH) SPF: (36) 8d X 2.5" (19" END LENGTH)CS16SYP: (22) 8d X 2.5"(13" END LENGTH) SPF: (26) 8d X 2.5" (15" END LENGTH)CS20SYP: (14) 8d X 2.5"(9" END LENGTH) SPF: (16) 8d X 2.5" (9" END LENGTH)DSP(8) 10d X 3" IN STUDS, (6) 10d X 3" IN DBL. PLT/(2) 10d X 3" IN SINGLE PLT.GBC(5) 8d X 1.5" IN BRACE, (7) 8d X 2.5" IN TOP PLATES (12 TOTAL)H2.5A/T(5) 8d X 2.5" IN RAFTER/TRUSS, (5) 8d X 2.5" IN PLATES (10 TOTAL)H3(4) 8d X 2.5" IN RAFTER/TRUSS, (4) 8d X 2.5" IN PLATES (8 TOTAL)H6(8) 8d X 2.5" IN STUDS, (8) 8d X 2.5" IN PLATES (16 TOTAL)H8(5) 10d X 1.5" IN RAFTER/TRUSS OR STUD, (5) 10d X 1.5" IN PLATES (10 TOTAL)HTS16(16) 10d X 1.5" NAILS TOTAL(FILL ALL HOLES)HTS20-36(24) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)LGT2 (2PLY)(14) 10d X 3.25" IN STUDS, (16) 10d X 3.25" IN GIRDER (30 TOTAL)LGT3 (3PLY)(26) 10d X 3.25" IN STUDS, (12) 1/4" X 2.5" SDS IN GIRDER (38 TOTAL)LGT4 (4 PLY)(30) 10d X 3.25" IN STUDS, (16) 1/4" X 3" SDS IN GIRDER (46 TOTAL)LS70(10) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)LS90(12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)LTP4(12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)LTS12, 16, 20(12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)MSTA12(10) 10d X 2.5" NAILS TOTAL (FILL ALL HOLES)MSTA18(14) 10d X 2.5" NAILS TOTAL (FILL ALL HOLES)MSTA24(18) 10d X 2.5" NAILS TOTAL (FILL ALL HOLES)MTS 12, 16, 24, 30(14) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)SP1(6) 10d X 3" IN STUDS, (4) 10d X 3" IN PLATES (10 TOTAL)SP2(6) 10d X 3" IN STUDS, (6) 10d X 3" IN PLATES (12 TOTAL)SPH4, 6, 8(12) 10d X 1.5" NAILS TOTAL (FILL ALL HOLES)SSP(4) 10d X 3" IN STUDS, (3) 10d X 3" IN DBL. PLT/(1) 10d X 3" IN SINGLE PLT.TSP(9) 10d X 1.5" IN STUDS, (6) 10d X 1.5" IN DBL. PLT (15 TOTAL)ALLOWABLE SPAN FOR STEEL LINTELS SUPPORTING BRICK VENEERSIZE OF STEELANGLENo. STORIESABOVEONE STORYABOVETWO STORIESABOVE3"x 3" x 14"6' - 0"4' - 6"3' - 0"4" x 3" x 14"8' - 0"6' - 0"4' - 6"5" x 3.5" x 516"10' - 0"8' - 0"6' - 0"6" x 3.5" x 516"14' - 0"9' - 6"7' - 0"(2) 6" x 3.5" x 516"20' - 0"12' - 0"9' - 0"* LONG LEG OF STEEL ANGLE SHALL BE PLACED IN A VERTICAL POSITION1.WIND PRESSURES SHOWN ABOVE ARE FOR STRUCTURES WITH A MEAN ROOF HEIGHT OF 30 FEET OR LESS WITH A ROOF PITCHB/T 2/12 AND 12/12 (VERT./HORIZ.). IF THE STRUCTURE IS OUTSIDE THESE PARAMETER PLEASE CONTACT THE ENGINEER.2.THE EFFECTIVE AREA IS EQUAL TO THE LENGTH * WIDTH OF THE PROPOSED OPENING OR SPAN. THE WIDTH SHALL BEPERMITTED TO BE NOT LESS THAN 13 OF THE SPAN LENGTH. THE EFFECTIVE AREA FOR FASTENERS SHALL NOT BE GREATERTHAN THE TRIBUTARY AREA B/T FASTENERS.3.ALL WIND PRESSURE VALUES IN POUNDS PER SQ. FT(PSF) & ARE CONSIDERED NOMINAL VALUES(ASD).a = 3.6'TRUSS PLAN & DETAILSTHIS ITEM HAS BEENELECTRONICALLY SIGNEDAND SEALED BY KEVIN C.MARTIN, PE ON 2/16/24 USINGA DIGITAL SIGNATURE.PRINTED COPIES OF THISDOCUMENT ARE NOTCONSIDERED SIGNED ANDSEALED AND THE SIGNATUREMUST BE VERIFIED ON ANYELECTRONIC COPIES11aaaaa aGABLE ROOFS23333222222222223222231111aaa a a HIP ROOFS33aMARTIN ENGINEERING, LLC. 450 STATE ROAD 13 N., #106-387 JACKSONVILLE, FL 32225 904-472-1459 FL C.A# 32027SHEETKEVIN C. MARTIN, PE #80359REVISION-2:REVISION-1:ISSUED:SCALE:DRAWN:DESIGNED:PROJECT #:2023 MARTIN ENGINEERING, LLC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT FROM MARTIN ENGINEERING, LLC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECTDIMENSIONS WITH THE ENGINEER. DIMENSIONS ARE CONSIDERED APPROXIMATE; CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. REVISIONS No.DESCRIPTION DATE NEW SINGLE FAMILY 808 AMBERJACK LANE ATLANTIC BEACH, FL 3223323-1017KCMKCMAS NOTED11/22/232/16/24 S-2FOUNDATION/FRAMING PLANFRAMING LEGEND PORCH BEAMS & OTHERSSTRUCTURAL BEARING WALLS STRUCTURAL SHEATHING LEGENDPOSTS/COLUMNS OR BOXED FRAMED COL. GIRDER ROOF/FLOOR TRUSS ABOVE1.ALL WOOD STRUCTURAL SHEATHING SHALL BE APA RATED, EXPOSURE 1.2.STRUCTURAL WOOD PANELS NOMINAL THICKNESS & SPAN RATINGS SHALL MEETTHE FOLLOWING MINIMUM REQUIREMENTS:7/16" = .437" THICKNESS - 24/16 SPAN RATING15/32" = .469" THICKNESS - 32/16 SPAN RATING19/32" = .594" THICKNESS - 40/20 SPAN RATING23/32" = .719" THICKNESS - 48/24 SPAN RATING3.ALL ROOF SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSIONPERPENDICULAR TO THE ROOF SUPPORTS.4.SHEATHING/SUBSTRATES & FASTENINGS FOR EACH ROOFING TYPE SHALL BE INACCORDANCE w/ THE FLORIDA PRODUCT APPROVAL.5.FASTENERS FOR ROOF SHEATHING GREATER THAN 1532" SHALL BE 8dCOMMON(.131x2 12") RING SHANK NAILS U.N.O.6.2x BLOCKING FOR EDGE NAILING SHALL BE INSTALLED IF NOTED ON THE PLANS.TYPESHEATHING15/32"OSB/PLYFASTENERSEDGES8d RING SHANKFLOOR**PORCHCEILINGS23/32" T&GOSB/PLY3/8"OSB/PLYWALLS7/16"(MIN.)OSB/PLYSEE SHEAR WALL LEDGED6" o.c.ROOFFIELD6" o.c.8d COM./BOX(U.N.O.)3" o.c.6" o.c.6" o.c.10d COMMON(GLUED & NAILED)6" o.c.8d COM./BOX 4" o.c. FIELD& EDGES 4'FROM ROOFEDGE/ENDWALLGABLE ENDSSHEATHING AREASNOTE TO CONTRACTOR:THE PLAN SHOWN ON THISSHEET IS FOR STRUCTURAL FOUNDATIONREQUIREMENTS AND LOCATIONS ONLY. REFER TOTHE ARCHITECTURAL PLANS FOR SLAB ANDFOUNDATION DIMENSIONS.3/8" THREADED ROD AT 48" O.C.(U.N.O.) w/ 3"x3"x0.229" SQ.WASHER FROM DBL. TOP PLATE TO FND. DRILL & EPOXY w/MIN. 7" EMBEDMENT. PLACE WITHIN 3" OF HEADER STUDGROUP,TRUSS BEARINGS, AND AT END OF EACHSHEARWALL SEGMENT WHERE SHOWN.FOUNDATION SCHEDULETYPEMARKWIDTHDEPTHREINFORCINGM16A1' - 0"(2) #5 CONTINUOUSTYPEF241' - 0"LENG.CONT.BOTTOMTRANSVERSE(2) #5 EACH WAY1' - 0"2' - 0"2' - 0"SPREAD FOOTINGN/AN/AINTERIOR MONOLITHIC1 - 4"CONT.N/A(2) #5 CONTINUOUSTE8/MA88"CONT.(1) #5 CONTINUOUS1' - 0"THICKND. EDGE/CURB STEPN/ASW-1SHEAR WALLS PER LEGEND ABOVESHEAR WALL LEGEND1.ALL SHEATHING MUST BE MINIMUM OF 716" RATED OSB OR PLYWOOD & FASTENEDPER THE TYPICAL DETAILS.2.SHEATHING MAY BE INSTALLED HORIZONTALLY OR VERTICALLY(U.N.O.). ALLHORIZONTAL EDGES MUST BE FULLY BLOCKED w/ 2x FRAMING LAID FLAT AGAINSTBACK SIDE OF SHEATHING FOR NAILING.3.A MINIMUM GAP OF 18" AT SHEATHING JOINTS MUST BE MAINTAINED.4.HOLDOWNS MUST BE PLACED AT EACH END OF SHEARWALL, U.N.O. SEE FRAMINGPLAN/DETAILS FOR HOLDOWNS TYPES, LOCATIONS, & INSTALLATION SPECS.5.ALL SILL ANCHORS(STUBBIES) SHALL BE A MIN. OF 3/8" IN DIA. w/ 3"x3"x18" SQUAREWASHER & NUT. PLACE ANCHORS ON EACH SIDE OF PLATE SPLICE. SEE TYPICALANCHOR DETAILS FOR INSTALLATION SPECS. FULL HT. ALL THREAD RODS MAY BEUSED IN LIEU OF STUBBIES PROVIDED THE MINIMUM STUBBIE SPACING INMAINTAINED.6.EXTERIOR STUCCO FINISH REQUIRES A MIN. 15/32" RATED SHEATHING INSTALLEDHORIZONTALLY w/ 2x FLAT WISE BLOCKED EDGES.7.MINIMUM END STUDS FOR EACH SHEAR WALL SECTION ARE SHOWN IN TABLE ABOVEAND SHALL BE CONSTRUCTED PER THE TYPICAL CORNER FRAMING DETAIL.8.SHEARWALL FASTENING SHOULD BE CONSTRUCTED PER THE TYPICAL SHEATHINGFASTENING DETAILS AND NOTES.SW-17/16" IDSHEATHING8d AT 6"8d AT 6"48" O.C.FASTENINGVERTICALEDGESHORIZONTAL EDGESFIELD8d AT 12"NAIL/SPACINGROWSINGLESILLANCHORS(STUBBIES)ENDSTUDGROUPS2FASTENER LEGEND8d COM./BOX8d RINGSHANK10d COMMON10d RINGSHANK10d x 1 12"12d COMMON16d COMMONNAILDIAMETERLENGTH0.131"/0.113"0.113"0.148"0.148"0.120"0.148"0.162"2 12"2 38"1 12"3"2 78"3 14"3 12"1.ALL NAILS SHALL BE COMMON NAILSUNLESS OTHERWISE NOTED ON THEPLANS.2.INSTALL 10d NAILS IF NOTOTHERWISE NOTED ON THE PLANS.3.INSTALL THE APPROPRIATEFASTENERS FOR PRESSURETREATED LUMBER. SEE NOTES ONSHEET S-1.SW-2*7/16" 8d AT 3"8d AT 3"24" O.C.8d AT 6"SINGLE2* SW-2 SHEATHING TO BE INSTALLED HORIZONTALLY w/ BLOCKED EDGESOPENING HEADER BEAMSNo. OF PLIESSIZE OF HEADERQUANTITYOF JACK STUDSQUANTITYOF KING STUDS(2) 2x____:__PLACE DBL. STUD GROUP UNDER PORCH BEAM BEARING INEXTERIOR WALL. NOTCH BEAM AT TOP PLATE (3" MAX) . PLACE (1) 38"A.T.R. WITHIN 3" OF BEAM BEARINGABCPLACE 3-PLY STUD GROUP UNDER GIRDER FLR. BEAM BEARINGABOVE. FASTEN STUDS T/G w/ 8d NAILS AT 8" O.C. STAGG. EACHSIDE. INSTALL ATR's WITHIN 3" OF BEARING IF SHOWN ON PLAN.M18CONT.N/A(2) #5 CONTINUOUSFOUNDATION PLANSCALE: 1/4" = 1'-0" 2nd FLR. FRAMING PLANSCALE: 1/4" = 1'-0" 1st FLR. FRAMING PLANSCALE: 1/4" = 1'-0" INSTALL 3-PLY STUD GROUP ON 2ND AND 1ST FLR.UNDERGIRDER ROOF TRUSS ABV. FASTEN STUDS T/G w/ 8d NAILS AT 8"O.C. STAGG. EACH SIDE. INSTALL (2) A.T.R. WITHIN 3" OFBEARING(1 EACH SIDE) FROM TOP PLT. TO FOUNDATION. INSTALL3-PLY BLOCKING IN FLOOR B/T TOP & BOT. STUD GROUPS.DINSTALL SIMPSON (1) HTT5 HOLDOWN AT BASE OF STUD GROUPWHERE SHOWN. INSTALL PER TYPICAL ANCHOR DETAILS(DETAIL 7/S-5)EINSTALL 3-PLY STUD GROUP UNDER GIRDER ROOF TRUSSBEARING ABOVE. FASTEN STUDS T/G w/ 8d NAILS AT 8" O.C.STAGG. EACH SIDE. FASTEN CORNER STUD GROUP TO TOP PLT.ABV. & FLOOR BEAM BELOW w/ (3) SDWC15600 TRUSS SCREWSTOP & BOT.(2) 2X82:1(2) 2X102:1(2) 2X81:1(2) 2X82:1(2) 2X122:1(2) 2X122:1(2) 2X62:1(2) 2X62:1(2) 2X62:1(2) 2X82:1(2) 2X82:1(2) 2X62:1(2) 2X82:1(2)2X12 6x6 No. 2 SYP POSTOR FRAMED BOXCOL. PER DETAIL10ON S-5SW-2(2) 2X124:2SW-2BBBBAADDDDSW-2A.T.R. AT 6' O.C1CS-61CS-63S-51B&DS-63S-53S-53S-55S-51S-51S-51S-51S-53S-54S-5D2-STORY1-STORY8S-58S-5CCCCWALLS BELOWWALLS BELOWEALL SLABS:0'-0" FIN. FLR. ELEV.(ASSUMED DATUM)4" DEEP POURED CONC, SLAB W/ 6X6,#10/10 W.W.W. OR FIBERMESH REINF.OVER 6 MIL VAPOR BARRIER OVERCLEAN COMPACTED FILL.SEE DETAIL 10ON S-4 FOR TYP. JOINT DETAILSELEV -0'-4" 4SLOPE 0.25"/12" MIN.MA16MA16MA16MA16F24F24TE8MA8EMBED. STRAPSREQUIRED SEE 9/S-4MA161S-43S-47S-45S-44S-44S-42S-42S-41S-41S-46S-45S-49S-49S-41S-22S-51S-55S-5EBBBBM18M18TE8TE8TE8TE8TE8TE81 - 6"EXTERIOR MONOLITHICM12A1' - 0"1' - 0"INTERIOR MONOLITHICF24F243'-6"F303'-6"2'-412"C.L.C.L.C.L.CALL EXTERIOR WALLS NOT LABELED AS SHEARWALLS SHALLBE CONSIDERED SHEARWALL "SW-1" AND CONSTRUCTEDACCORDING TO THE SHEARWALL LEGEND, U.N.O.M18M18M1810'-4"F24C.L.THIS ITEM HAS BEENELECTRONICALLY SIGNEDAND SEALED BY KEVIN C.MARTIN, PE ON 2/16/24 USINGA DIGITAL SIGNATURE.PRINTED COPIES OF THISDOCUMENT ARE NOTCONSIDERED SIGNED ANDSEALED AND THE SIGNATUREMUST BE VERIFIED ON ANYELECTRONIC COPIESF301' - 0"(3) #5 EACH WAY2' - 6"2' - 6"SPREAD FOOTINGN/AFNSTALL 4X8 No. 2 SYP POST IN WALL UNDER GIRDER/BM. ABV.INSTALL (2) A.T.R. WITHIN 3" OF BEARING(1 EACH SIDE) FROM TOPPLT. TO FOUNDATION. SEE CALLOUT 2 ON S-3 FOR REQ. BEARINGBLOCKS.F2 PLY LVL BEAM FASTENING3 ROWS-16d NAILS @ 12" O.C.(N.T.S.)3 PLY LVL BEAM FASTENING3 ROWS-16d NAILS @ 12" O.C. EACH SIDE(N.T.S.)BEAM DEPTH > 14"VAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILL4'' CONCRETE SLAB W/6X6 W1.4x1.4 ORFIBERMESH.SEE FOOTINGSCHEDULE12" MIN.INTERIOR MONOLITHIC FOOTING. SEEFOOTING SCHEDULE FOR SIZE ANDREINFORCINGINTERIOR MONO.w/ CURB.CURB HEIGHT VARIES, SEE ARCHPLANS.111(1) #4 BAR IN CURB CONTIN. (FOR CMUWALLS ONLY)6"MINMARTIN ENGINEERING, LLC. 450 STATE ROAD 13 N., #106-387 JACKSONVILLE, FL 32225 904-472-1459 FL C.A# 32027SHEETKEVIN C. MARTIN, PE #80359REVISION-2:REVISION-1:ISSUED:SCALE:DRAWN:DESIGNED:PROJECT #:2023 MARTIN ENGINEERING, LLC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT FROM MARTIN ENGINEERING, LLC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECTDIMENSIONS WITH THE ENGINEER. DIMENSIONS ARE CONSIDERED APPROXIMATE; CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. REVISIONS No.DESCRIPTION DATE NEW SINGLE FAMILY 808 AMBERJACK LANE ATLANTIC BEACH, FL 3223323-1017KCMKCMAS NOTED11/22/232/16/24 ROOF TRUSS PLANSCALE: 1/4" = 1'-0" S-3TRUSS PLAN**SIMPSON SDWC15600 TRUSS SCREWS THROUGH TOP PLATES/HEADERS INTO TRUSSES (615# UPLIFT)(USE 1 SCREW IN EACH PLY OF MULTI-PLT GIRDER TRUSSES)NOTES:1.**MULTI-PLY TRUSSES MUST HAVE (1) UPLIFT CONNECTOR PER TRUSS PLY UNLESS NOTED OTHERWISE.2.SEE APPROVED TRUSS SHOP DRAWINGS FOR TRUSS TO TRUSS CONNECTORS.TRUSS TO TOP PLATE CONNECTOR LEGEND1.ALL ROOF FRAMING MATERIALS SHALL BE No. 2 SOUTHERN YELLOW PINE (SYP) AT 24" O.C., U.N.O.2.ALL ROOF RAFTERS AND COLLAR TIES TO BE A MIN. OF 2x6 No. 2 SYP. RIDGE BOARDS TO BE MIN. OF 2x8 No. 2SYP.3.ALL SLEEPERS TO BE A MIN. OF 2x8 No. 2 SYP FASTENED TO EACH TRUSS/RAFTER BELOW w/ (4) 16d NAILS.4.FASTEN ROOF RAFTERS TO RIDGE BOARDS AND "SLEEPERS" W/ SIMPSON A35 CLIPS, U.N.O.5.FASTEN COLLAR TIES TO ROOF RAFTERS W/ (5) 16d NAILS AT EACH END.6.COLLAR TIES SHALL NOT TO BE FASTENED HIGHER THAN 2/3 OVERALL ROOF RAFTER HEIGHT.OVER FRAMING NOTES:SDWC 15600/15450 TRUSS SCREW INSTALLATIONDo not install SDWC inhatched area 12"Min12" min134" maxOverhang30°MaxRafter to Top Plate shown(Truss to Top Plate similar)SDWC15600Note: 1. Sloped-roof rafters may be sloped up to and including a 12:12 pitchand must be "birdsmouth" cut.2. Reference detail 4 for installation instructions.Note: Reference detail 2a for installation angle limitSDWC15600Note: Sloped-roof rafters may be sloped up to and including a 12:12 pitch andmust be "birdsmouth" cut.3½" minOptimal 2212° 0°10°30°12"MaxRafter to Top Plate shownTruss to Top Plate similarSDWC15600SDWC15600SDWC156003"Optimal 2212° 0°10°30°SDWC15600CODES: SDWC15600: FL 13975.21.ALL TRUSSES SHALL BE DESIGNED AND APPROVED BY THE DELEGATED TRUSS ENGINEER AND BE LICENSED IN THE STATE OFFLORIDA.2.ALL TRUSSES SHALL BE DESIGNED TO MEET OR EXCEED THE ULTIMATE WIND SPEED, EXPOSURE CATEGORY, AND LOADINGSSPECIFIED ON THE STRUCTURAL NOTES PAGE S-1.3.ALL ROOF AND FLOOR TRUSS ENGINEERING SHALL MATCH THE PROVIDED LAYOUT SHOWN IN THESE PLANS. ANY VARIATIONSFROM THE PROVIDED LAYOUTS SHOULD BE REPORTED TO THE ENGINEER OF RECORD BEFORE CONSTRUCTION BEGINS.4.TRUSSES MUST BE CAPABLE OF TRANSFERRING LATERAL LOADS TO THE STRUCTURAL LOAD BEARING WALLS SHOWN ON THEFRAMING PLAN.5.UPLIFTS HAVE BEEN CALCULATED BY THE ENGINEER OF RECORD AND ALL CONNECTIONS FROM TRUSSES TO STRUCTURE HAVEBEEN SPECIFIED AND SHOULD BE FOLLOWED. ANY QUESTIONS AS TO THE SIZE, TYPE, OR VALUE OF A NAIL, STRAP OR CLIPSHOULD BE VERIFIED BY THE STRUCTURAL ENGINEER.6.PERMANENT TRUSS WEB BRACING SHALL BE INSTALLED WITH THE SAME QUANTITY AND LOCATIONS SHOWN ON THE TRUSSENGINEERING SHOP DRAWINGS. CONTINUOUS LATERAL BRACING SHALL BE IN ACCORDANCE WITH THE DETAILS7.GYPSUM CEILING: FASTENING SHALL BE IN ACCORDANCE w/ TABLE R702.3.5 OF THE FBC.8.TABLE 2304.9.1 OF THE FLORIDA BUILDING CODE NAILING REQUIREMENTS ARE IN ADDITION TO THE STRAPPING REQUIREMENTS.9.PROVIDE 5/8" TYPE X GYP. BD. @ GARAGE CLG. BENEATH HABITABLE SPACE & 1/2" MIN GYP. BD. @ GARAGE SIDE WALLS &UNDERSIDE OF STAIRWAY IF USED AS ACCESSIBLE SPACE.10.ALL TRUSS FABRICATION, HANDLING, SHIPPING, INSTALLING, AND BRACING SHALL BE IN ACCORDANCE WITH BCSI 1-03 MANUAL(BUILDING COMPONENT SAFETY INFORMATION) PRODUCED BY THE SBCA AND TPI.TRUSS NOTES:ABCDENOTES BOTH UPLIFT CONNECTORS REQ. FOR GIRDER TRUSSDOUBLE (2) SIMPSON SDWC15600 TRUSS SCREWS(SIMPSON CONFIG. B ON THIS SHEET)(1195#UPLIFT)SIMPSON HTS16 TWIST STRAP. FILL ALL HOLES w/ 10dx1.5" NAILS. (1310# UPLIFT)XXFLOOR TRUSS PLANSCALE: 1/4" = 1'-0" FLOOR BEAM SCHEDULE ** BM-1BM-2(2) 1.75"x16" 2.0E LVL(3) 1.75"x16" 2.0E LVLTRUSS TO TRUSS/BEAM CONNECTIONSPER TRUSS SHOP DRAWINGS2x6 No. 2 SYP LEDGER BOARDS P.T. FASTEN TOFRAMING w/ 14"x3.5" SDS SCREWS AT 16" O.C. STAGG.FASTEN TRUSSES TO LEDGER BOARD w/ A35 CLIPS.1FLOOR SHEATHINGPER LEGEND ON S-2ROOF SHEATHINGPER LEGEND ON S-2PRE-ENGINEERED ROOF TRUSSES AT 24" O.C.P R E - E NG I N E E R E D F LOO R T R U S S E S A T 2 4 " O . C .BAABAACBCBCBCBBBDDAA11BM-1BM-1BM-1DSIMPSON MSTA18 STRAPS AT 48" O.C. (GABLE ENDS ONLY). USE 10dx1.5" NAILS. (1315# UPLIFT)8S-511S-511S-5PRE-ENGINEERED ROOF TRUSSES AT 24" O.C.2S-62S-66S-5BM-1BM-2THA413NOTE TO TRUSS DESIGNER: ADJUSTTRUSS LOCATIONS ABOVE & BELOWAC CHASE LOCATIONNOTE TO TRUSS DESIGNER: ADJUSTTRUSS LOCATIONS ABOVE & BELOWAC CHASE LOCATIONBCCACBBC2TRUSS PLAN LEGEND BM-1FLOOR TRUSS.ROOF TRUSSFLOOR/CEILING BEAMLEDGERSC2INSTALL (2) 2X4 No. 2 SYP, 16" LG. BEARING BLOCKSTO FLR. TRUSS/BEAM (1 ON EA. SIDE). FASTEN TOSIDE OF TRUSS/BEAM w/ 10d NAILS AT 3" O.C. STAGG.BEARING BLK's TO BEAR FLUSH & FLAT ON PLT.BELOW.** FLOOR GIRDER TRUSSES MAY BEUSED IN LIEU OF LVL BEAMS IFSPECIFIED BY TRUSS ENGINEERTHIS ITEM HAS BEENELECTRONICALLY SIGNEDAND SEALED BY KEVIN C.MARTIN, PE ON 2/16/24 USINGA DIGITAL SIGNATURE.PRINTED COPIES OF THISDOCUMENT ARE NOTCONSIDERED SIGNED ANDSEALED AND THE SIGNATUREMUST BE VERIFIED ON ANYELECTRONIC COPIESMARTIN ENGINEERING, LLC. 450 STATE ROAD 13 N., #106-387 JACKSONVILLE, FL 32225 904-472-1459 FL C.A# 32027SHEETKEVIN C. MARTIN, PE #80359REVISION-2:REVISION-1:ISSUED:SCALE:DRAWN:DESIGNED:PROJECT #:2023 MARTIN ENGINEERING, LLC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT FROM MARTIN ENGINEERING, LLC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECTDIMENSIONS WITH THE ENGINEER. DIMENSIONS ARE CONSIDERED APPROXIMATE; CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. REVISIONS No.DESCRIPTION DATE NEW SINGLE FAMILY 808 AMBERJACK LANE ATLANTIC BEACH, FL 3223323-1017KCMKCMAS NOTED11/22/232/16/24 FOUNDATION DETAILS S-4THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON2/16/24USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES8" MIN.20" MAXSEE FTG.SCHEDULE12" MIN.(D)6"GRADE8" MAX 4'' CONCRETE SLAB W/ 6X6W1.4x1.4 OR FIBERMESH6" OPT. BRICK LEDGE w/ (1) #4 OR #5BAR FROM GRADE TO BOT. OFFOOTING. SEE PLAN FOR LOCATIONS.EXTERIOR MONOLITHIC FOOTINGVAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILLSEE FTG.SCHEDULE(W)MONOLITHIC FOOTING, SEEFOOTING SCHEDULE FOR SIZE &REINFORCINGINSTALL TRANSFER BARS PERPLANS (CMU WALLS ONLY)1111 12" RECESS (CMU ONLY)VAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILL4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESH.F.F.E.SEE FTG.SCHEDULE(W)12" MIN. (D)INTERIOR MONOLITHIC FOOTING. SEEFOOTING SCHEDULE FOR SIZE ANDREINFORCINGINTERIOR MONOLITHIC FOOTING1128" MINSEE FTG.SCHEDULE(W)12" MIN. (D)6"GRADE8" MAX 4'' CONCRETE SLAB W/ 6X6W1.4x1.4 OR FIBERMESH6" OPT. BRICK LEDGE w/ (1) #4 OR #5 BARFROM GRADE TO BOT. OF FOOTING. SEE PLANFOR LOCATIONS.GARAGE/CURB MONOLITHIC FOOTINGVAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILLVARIES 6" MIN.HEIGHT OF CURB VARIES w/ SLOPE OFGARAGECURB w/ (1) #5 CONTINUOUS (CMU WALLS ONLY,U.N.O.)(1) #5 DOWEL w/ 6" BEND AT BOT. &IN CURB. PLACE AT CORNERS,CURB ENDS, AND AT 48" O.C.INSTALL TRANSFER BARS PERPLANS (CMU WALLS ONLY)MONOLITHIC FOOTING, SEEFOOTING SCHEDULE FOR SIZE &REINFORCING113VAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILL4'' CONCRETESLAB W/ 6X6W1.4x1.4 ORFIBERMESH.12" MIN. (D)INTERIOR MONOLITHIC FOOTING. SEEFOOTING SCHEDULE FOR SIZE ANDREINFORCINGINTERIOR MONO. STEPDOWN FTG.CURB HEIGHT VARIES, SEE ARCHPLANS.114(1) #4 BAR IN STEP CONTIN. (FORGARAGE ONLY)1 12" RECESS (CMU ONLY)SEE FTG.SCHEDULE(W)12" MIN.(D)SEE FOOTINGSCHUDLE(W)4"THICKENED EDGE SLABTHICKENED EDGE SLAB, SEE FOOTINGSCHEDULE FOR SIZE & REINFORCING4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESHVAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILL1154"8"8"4"12" MIN. (D)SEE ARCH. PLANSVAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILL4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESH.8"x8" FOOTING AT STEPCURB STEP FOOTINGF.F.E.(1) #4 BAR IN STEPCONTIN. (GARAGEONLY)11612" MIN (D)SEE FOOTINGSCHEDULE(W)SPREAD FTG. AT THICKENED EDGE4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESH.VAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILLFOOTER AT THICKENED EDGE. SEESCHEDULE FOR SIZE ANDREINFORCING.117FOOTING - 2 FOOTING -1 48 BAR Ø LAPHMIN. 12"OR H48 BAR Ø LAPHUSE Z-BAR FOR STEP DOWN.MAINTAIN 48 BARDIAMETERS FOR SPLICESINTO EACH FOOTING.EXTEND BOT. BARSFROM FOOTING-1 INTOFOOTING-2 A MIN. OF 8".STEP DOWN VARIES PERELEVATION CHANGE.CONTACT ENGINEER IFSTEP IS MORE THAN 24"STEPPED FOOTING12PLACE VERTICALREINFORCEMENT ONEACH SIDE OF FOOTINGELEV. CHANGEKEYED JOINT (AT SLAB MID-DEPTH)PAINT w/ CURING COMPOUND ASBOND BREAK BEFORE ADJACENTSLAB IS PLACED3/4" MINT/4 (1 1/2" MIN) TSLAB REINFORCINGPER PLANIV:3H3/4" SAW CUT (SAWSAME DAY AS POUR)FILL W/JOINT SEALER1/8x3/4"PRE-MOLDEDSTRIPFLUSH W/SURFACESLAB REINFORCINGPER PLANSAW CUTJOINTFORMEDJOINTNOTE: CONTROL JOINTS TO BE 15'-0" OC MAXCONSTRUCTION JOINTCONTROL JOINTTYPICAL JOINT DETAILS102'-6"1'- 8" DIA. (DECKS)1'-0" DIA. (STAIRS)4" MIN.SYP P.T. POST, SEEPLAN FOR SIZE(GROUND CONTACTUC4B PRESSURETREATED)EMBED POST MIN. 2'-6"IN WET CONCRETEROUND POSTFOOTING w/ 3,000PSI CONCRETEFIXED POST FOOTING11 GRAVELBASE,TYP.(1) No. 4, BAR,12" LG.TOP & BOT.,TYP.SEE FOOTING SCHEDULE(W)SEE FOOTING SCHEDULE (D)EXTERIOR STEMWALL AT SHOWER12"MIN.GRADESTEMWALL FOOTER. SEE SCHEDULEFOR SIZE AND REINFORCING.FORM & POUR SHOWERCURB/RECESS w/ (1) #4CONTIN.VERTICAL REINFORCING TO BE (1) #5AT 48" O.C. & AT CORNERS w/ MIN. 7"BEND AT BOTTOM & 12" MIN. BEND INTOSLAB, U.N.O.4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESH OVER 6 MIL VAPORBARRIER & CLEAN COMPACT FILLBEARING SOILS TO BECOMPACTED & FREE OFDELETERIOUS MATERIALSADD (1) #4 MIN. INFOOTING FOR BRICKLEDGENOTE: CONTACT ENGINEER IF STEMWALL EXCEEDS 48",FROM T.O.S TO FOOTER (6 COURSES). U.N.OHEIGHT OF CURB PER SHOWER RECESS6" MIN.158"x16" CMU STEMWALL. FILLREINFORCED CELLS SOLIDSEE FOOTING SCHEDULE(W)SEE FOOTING SCHEDULE (D)GARAGE/STEP STEMWALL FOOTINGGRADESTEMWALL FOOTER. SEE SCHEDULEFOR SIZE AND REINFORCING.U-BLOCK w/ (1) #5 BARCONTINUOUSVERTICAL REINFORCING TO BE (1) #5AT 48" O.C. & AT CORNERS w/ MIN. 7"BEND AT BOTTOM & 12" BEND INTOU-BLOCK, U.N.O.4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESH OVER 6 MIL VAPORBARRIER & CLEAN COMPACT FILLBEARING SOILS TO BECOMPACTED & FREE OFDELETERIOUS MATERIALSADD (1) #4 MIN. INFOOTING FOR BRICKLEDGENOTE: CONTACT ENGINEER IF STEMWALL EXCEEDS 48",FROM T.O.S TO FOOTER (6 COURSES).FILL SLAB TO STEMWALL JOINT w/ELASTOMERIC SEALANT FILLER.HEIGHT OF CURB VARIES w/ SLOPE OFGARAGE OR STEP8"x16" CMU STEMWALL. FILLREINFORCED CELLS SOLID1412" MIN.SEE FOOTING SCHEDULE(W)SEE FOOTINGSCHEDULE(D)STEMWALL FOOTING12" MIN GRADEF.F.E.STEMWALL FOOTING. SEE SCHEDULEFOR SIZE AND REINFORCING.CMU HEADER BLOCK w/(1) #5 BAR CONTINUOUSVERTICAL REINFORCING TO BE (1) #5AT 48" O.C. & AT CORNERS w/ MIN. 7"BEND AT BOTTOM & 12" MIN. BEND INTOSLAB, U.N.O.4'' CONCRETE SLAB W/ 6X6 W1.4x1.4 ORFIBERMESH OVER 6 MIL VAPORBARRIER & CLEAN COMPACT FILLBEARING SOILS TO BECOMPACTED & FREE OFDELETERIOUS MATERIALSADD (1) #4 MIN. INFOOTING FOR BRICKLEDGENOTE: CONTACT ENGINEER IF STEMWALLEXCEEDS 48", FROM T.O.S TO FOOTER (6COURSES).8" MIN138"x16" CMU STEMWALL. FILLREINFORCED CELLS SOLIDMONOLITHIC FOOTINGw/ CURB. SEE DETAILS& SCHEDULE FOR SIZE& REINFORCINGINSTALL #5 VERTICALBARS AT 18" O.C., OR 2TOTAL MIN. EXTENDINTO CURB & BEND 7"MIN. AT BOT.PLACE (1) #5 BAR CONTIN. INCURB AT GARAGE RETURN w/MIN. 28" BEND INTOADJACENT WALLGARAGE RETURN FTG.VAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILLGARAGE DOORTHICKENED EDGEFOOTING. SEESCHEDULE FOR SIZE &REINFORCINGUSE Z-BAR FORTHICKENED EDGE TOGARAGE RETURNFOOTINGREINFORCEMENT.VARIES9 GARAGE RETURN WALLEMBED (1) STHD14 AT EACHEND OF GARAGE RETURNWALL. FILL ALL HOLES w/16d NAILS STEMWALL FOOTINGw/ CURB. SEE DETAILS& SCHEDULE FORSIZE & REINFORCINGINSTALL #5 VERTICALBARS AT 18" O.C., OR 2TOTAL MIN. EXTENDINTO CURB & BEND 7"MIN. AT BOT. FILL CELLSSOLIDVAPOR BARRIER (6-MILMIN.) OVER CLEANCOMPACTED FILLGARAGE DOORTHICKENED EDGEFOOTING. SEESCHEDULE FOR SIZE& REINFORCINGUSE Z-BAR FORTHICKENED EDGE TOGARAGE RETURNFOOTINGREINFORCEMENT.VARIES(2 COURSE MAX)GARAGE RETURN WALLMONOLITHICSTEMWALL2 COURSES OR LESS: EMBED (1)STHD14RJ AT EACH END OF GARAGERETURN WALL. FILL ALL HOLES w/ 16dSINKERS.GREATER THAN 2 COURSES:FASTEN (1)MSTCM40 TO EACH END OF GARAGERETURN WALL. USE (1) 14"x2 14" TITENSCREWS INTO STEMWALL & (26) 16dSINKERS IN STUDS.STEMWALL FTG. & PADGRADESEE TYP. STEMWALLDETAIL FOR SPECS.PAD FOOTING FOR PORCHPOST SUPPORT. SEE PLAN &SCHEDULE FOR SIZE,LOCATION, & REINFORCINGNOTE: CONTACT ENGINEER IF STEMWALLEXCEEDS 48", FROM T.O.S TO FOOTER (6COURSES).SEEFOOTINGSCHEDULE(W)16SEE TYP. STEMWALLDETAIL & SCHEDULE FORSIZE & REINFORCINGPOST w/ HOLDOWN. SEE FRAMINGPLANS & DETAILS FOR SPECS.8" MIN. (D)(1) No. 5 BAR CONTIN.,TYPSPREAD FOOTING w/ MONO FTG.812" MIN.GRADE4'' CONCRETESLAB W/ 6X6W1.4x1.4 ORFIBERMESHVAPOR BARRIER(6-MIL MIN.) OVERCLEANCOMPACTED FILLSEE FOOTINGSCHEDULE(W)SPREAD FTG. ATEXTERIOR MONO. SEEFOOTING SCHEDULEFOR SIZE &REINFORCING11SEE FTG. SCHED. (D) MARTIN ENGINEERING, LLC. 450 STATE ROAD 13 N., #106-387 JACKSONVILLE, FL 32259 904-472-1459 FL C.A# 32027SHEETKEVIN C. MARTIN, PE #80359REVISION-2:REVISION-1:ISSUED:SCALE:DRAWN:DESIGNED:PROJECT #:2018 MARTIN ENGINEERING, LLC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT FROM MARTIN ENGINEERING, LLC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECTDIMENSIONS WITH THE ENGINEER. DIMENSIONS ARE CONSIDERED APPROXIMATE; CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. REVISIONS No.DESCRIPTION DATE NEW SINGLE FAMILY 808 AMBERJACK LANE ATLANTIC BEACH, FL 3223323-1017KCMKCMAS NOTED11/22/23 FRAMING DETAILS S-5TYPICAL WALL SECTION2TYPICAL TWO STORY WALL SECTION1SEE FOUNDATION DETAILSFOR GARAGE RETURN SPECS.& REINFORCINGREQUIREMENTSEMBED STDH14 STRAPTIE-DOWN ON EACH SIDE OFGARAGE RETURN. FILL ALLHOLES w/ 16d NAILSNo. OF KING STUDS SHOWNON FRAMING PLANNo. OF JACK STUDS SHOWNON FRAMING PLAN(1) #5 CONTIN. IN CURB ATRETURNS w/ MIN. 28" BENDINTO ADJACENT WALL.VARIES INSTALL TOP PLATE &FASTEN TO HEADERBTM. w/ (2) ROWS OF16d NAILS AT 3" O.C.NAIL SHEATHING TO ALLFRAMING w/ 8d NAILS AT 3"O.C.GARAGE HEADER PERFRAMING PLANFASTEN SHEATHING TO TOP PLATE& REMAINING HEADER PER SHEARWALL LEDGED & FRAMING DETAILSFASTEN SHEATHING ATHEADER w/ 8d NAILS IN A 3"O.C. GRID.THICKENED EDGE.SEE FOUNDATIONPLANS & DETAILS.16"O.C.ADDITIONAL WALL STUDS AT16" O.C. AS REQ.GARAGE RETURN DETAIL5VARIES 16"O.C.(1) MSTA24 STRAP FROM EACHJACK STUD TO HEADER, TYPTYPICAL HEADER DETAIL33" MAXOPENINGVARIESHEADER BEAM PER FRAMING PLAN. FASTENTOGETHER W/ (2) ROWS OF 10d NAILS @ 8"O.C. SEE FRAMING PLAN FOR SIZES. SEEFASTENING DETAILS FOR LVL HEADERSFASTEN KING STUD TO HEADERBEAM PER TABLE SHOWN ON THISDETAILKING & JACK STUDS PERFRAMING PLAN, TYP.SILL STUD SPECS PER TABLEON THIS DETAIL,TYP.FASTEN KING & JACK STUDSTOGETHER w/ (2) ROWS OF .131x 3" NAILS AT 8" STAGGERED,TYP.TYP. WALL FRAMING PER FRAMINGPLAN. FASTEN TO PLATES w/ (2) .131x 3" END NAILS OR (3) .131 x 3"TOENAILS, TYP.FOUNDATION: ANCHORS REQ.AT FOUNDATION PERSHEARWALL LEGEND ONFRAMING PLAN U.N.O.16" O.C.FLOOR SYSTEM: FASTEN SILL TOBAND/RIM BOARD PER TYPICALWALL SECTIONSFOUNDATION OR FLOOR SYSTEMTYPICAL WALL SHEATHINGPER SHEAR WALL LEGENDON FRAMING PLANFLOOR OR ROOF SYSTEMFLOOR SYSTEM: FASTENFLOOR TRUSS/JOISTS/RIMBOARD TO TOP PLATE PERTYPICAL WALL SECTIONSROOF SYSTEM: FASTENTRUSSES/RAFTERS TO TOPPLATE PER TRUSS PLAN ORROOF FRAMING PLANKING STUDS TO HEADER NAILING2X6(3) NAILS PER PLY2X8(4) NAILS PER PLY2X10(5) NAILS PER PLY2X12(6) NAILS PER PLY9.5" LVL(5) NAILS PER PLY11 78"LVL(6) NAILS PER PLY14" LVL(7) NAILS PER PLY16" LVL(8) NAILS PER PLYTHREADED ROD TIE DOWN ANCHORSFROM UPPER MOST TOP PLATE TOFOUNDATION ON EACH SIDE OF OPENING.SEE FRAMING PLAN FOR SIZE, LOCATION,& INSTALL SPECS.OPENING HEAD/SILL STUD SPECSOPENINGWIDTHATTACHMENT0' - 8"(3) .131"x3" TOE-NAILS8' - 12' (6) .131"x3" TOE-NAILS12' - 18' (2) A35 CLIPS2-PLY HEAD/SILL STUDS: 6' - 10'3-PLY HEAD/SILL STUDS: 10' - 18'HEAD STUD SPECS PERTABLE ON THIS DETAIL,TYP.3" MAXTYPICAL ALL-THREAD RODTIE-DOWNS. INSTALLWITHIN 3" OF EACH KINGSTUD GROUP. SEEFRAMING PLAN FOR SIZE,SPACING, & SPECS,TYP.IF HEADER SPAN EXCEEDS THREADED RODMIN. SPACING INSTALL (1) SPH4/6 ORSDWC15600 FROM TOP PLT. TO HEADER ATMIN. A.T.R. ROD SPACING ALONGSPAN.(1-STORY ONLY)FASTEN TRUSSES TO TOPPLATE PER UPLIFTCONNECTOR LEGEND ONTRUSS PLAN, TYP.(2) 2x No. 2 SYP TOP PLATEFASTENED w/ 2 ROWS OF .131x3"NAILS AT 12" O.C. STAGGERED.MINIMUM 48" LAP WITH (24).131x3" NAILS IN LAP.APA RATED OSB/PLYWOODSHEATHING. SEESHEARWALL LEGEND FORFASTENING AND OTHERSHEATHING SPECS.2x No. 2 SYP PT BOTTOMPLATE. FASTEN TOFOUNDATION w/ANCHORBOLTS PER SHEARWALLLEGEND.SEEFOUNDATIONPLAN FORFOOTINGDETAILS. APA RATED OSB/PLYW. ROOFDECK. SEE SHEATHING LEGEND ONFRAMING PLAN S-3 FOR SPECS.GYPSUM WALL BOARD,FASTEN PER FBC TABLER702.3.5GYPSUM CEILINGBOARD, FASTEN PERFBC TABLE R702.3.52x FASCIA FASTEN TOTRUSS/RAFTER TAILS w/(2) 10d NAILS, TYP.PRE-ENGINEERED TRUSSES ORCONVENTIONAL ROOF FRAMING. SEETRUSS PLAN OR ROOF FRAMING PLAN.ALL THREAD TIE DOWNRODS FROM TOP PLATETO FOUNDATION, SEEFRAMING PLAN FOR SIZE,LOCATIONS, & INSTALLSPECS.2x6 No. 2 SYP PTBOTTOM PLATE.FASTEN TOFOUNDATION w/ MIN. 38"ANCHOR BOLTS PERSHEARWALL LEGEND &TYP. ANCHOR DETAILSSEE FOUNDATION PLANFOR FOOTING DETAILS.APA RATED OSB/PLYW. ROOFDECK. SEE SHEATHINGLEGEND ON FRAMING PLAN2x FASCIA FASTEN TOTRUSS/RAFTER TAILS w/(2) 16d NAILS, TYP.APA RATED FLOORSHEATHING NAILED &GLUED TO FLOORFRAMING. SEE FRAMINGPLAN FOR SIZES,FASTENING, & OTHERSPECIFICATIONS.APA RATED OSB/PLYWOODSHEATHING. SEE FRAMINGPLAN FOR FASTENING ANDOTHER SHEATHING SPECS.2x4 SPF No. 2 STUDS AT 16"O.C.SEETRUSSMANUF.PRE-MANUFACTUREDFLOOR TRUSSESFASTEN BTM.PLATE TO RIBBONBOARD w/ .131x3"NAILS AT 8" O.C.FASTEN TRUSSES TO TOPPLATES w/ (3) .131x3"TOE-NAILS.2X4 No. 2 SYP RIBBONBOARD CONTIN.FASTEN TO TRUSSESw/ (3) .131x3" NAILSALL THREAD TIE DOWNRODS FROM TOP PLATE TOFOUNDATION, SEE FRAMINGPLAN FOR SIZE, LOCATIONS,& INSTALL SPECS.ALL THREAD TIE DOWN RODSFROM TOP PLATE TOFOUNDATION, SEE FRAMINGPLAN FOR SIZE, LOCATIONS,& INSTALL SPECS.(2) 2x No. 2 SYP TOP PLATEFASTENED w/ 2 ROWS OF .131x3"NAILS AT 12" O.C. STAGGERED.MINIMUM 48" LAP WITH (24).131x3" NAILS IN LAP.GYPSUM CEILINGBOARD, FASTEN PERFBC TABLE R702.3.5GYPSUM CEILINGBOARD, FASTEN PERFBC TABLE R702.3.5GYPSUM WALL BOARD,FASTEN PER FBC TABLER702.3.5APA RATED OSB/PLYWOODSHEATHING. SEESHEARWALL LEGEND FORFASTENING AND OTHERSHEATHING SPECS.FASTEN TRUSSES TO TOPPLATE PER UPLIFTCONNECTOR SCHEDULE ONTRUSS PLAN, TYP.2x4 SPF No. 2 STUDS AT 16"O.C.,TYP.(INTERIOR BEARING WALL2x4 AT 16" O.C.)2x SPF BLOCKING/NAILERSB.T EACH TRUSS OR ALONGTOP PLATE(PARALLELTRUSSES). FASTEN TO DBL.TOP PLATE w/ 10d NAILS AT3" O.C.PRE-MANUF. TRUSSES ORCONVENTIONALLY FRAMEDROOF PER SHOP DRAWINGSAND/OR ROOF FRAMING PLAN2x SPFBLOCKING/NAILERS B.TEACH TRUSS ORALONG TOP OFBEAM(PARALLELTRUSSES). FASTEN TOBEAM w/ 10d NAILS AT3" O.C.PORCH BEAMS. SEEFRAMING PLAN FORSIZES.FASTEN EACH PORCHBEAM TO POST w/ (1)MSTA24 SIMPSONSTRAPS -1 ON EACHSIDE(U.N.O.).No. 2 SYP PT. PORCHPOST. SEE PLAN FORSIZE & LOCATION(OPT.BOX COL. PER 10/S-5)SIMPSON ABU FORPOST. SEE DETAIL10/S-5 FOR BOX COL.HOLDOWNS.PORCH POST FTG.SEE FOUNDATIONPLAN & DETAILSTYPICAL EXTERIORBEARING WALL. SEEFRAMING PLAN &TYPICAL WALL SECTIONSTYPICAL WALLFOUNDATIONS.SEEFOUNDATIONPLAN & DETAILSPORCH FRAMING DETAIL4MIN. 38" PLYWOOD OR OSBFASTENED TO PORCHCEILING ROOF FRAMING w/8d NAILS AT 6" O.C. ALONGEDGES & 12" O.C. IN FIELD,BLOCK ALL UNSUPPORTEDEDGESOR1x4 OR 2x4 No. 2 SYP AT 16"O.C. w/ (2) .131x3" NAILS ATEACH TRUSS INTERSECTION2x4 SPF No. 2 STUDS AT 16"O.C.PRE-ENGINEERED TRUSSES ORCONVENTIONAL ROOF FRAMING. SEETRUSS PLAN OR ROOF FRAMING PLAN.HTT5 HOLDOWNFILL ALL HOLES w/ 16d x 2 12"NAILS OR #10x1 12" SDFASTERS, PER SIMPSONSPECS.MIN. 2-PLY STUD GROUP OR3"x3.5" MEMBER SIZEMINIMUM 5/8"THREADED ROD2x PT SOLEPLATE, TYPDRILL & EPOXY 5/8"THREADED ROD w/ MIN.7" EMBEDMENT INTOFOUNDATION.TYPICAL ANCHOR(STUBBIE)MIN. 3"x3"X 0.229"SQUARE WASHER & NUTMIN. 38" THREADEDROD ANCHOR(U.N.O)TYP 2x P.T. SOLE PLATETHREADED ROD:DRILL & EPOXY3/8" THREADED ROD w/ MIN. 7"EMBEDMENT INTO FOUNDATION.ORTITEN HD: 3/8" TITEN HD ANCHOR8"LG.ABU44Z(ABU66, ABU88 similar)ABU66Z POST BASE. FILLALL HOLES w/ 16d NAILS.ABU44:. 12" ANCHOR BOLTOR THREADED ROD.ABU66: 58" ANCHOR BOLT ORTHREADED ROD.ABU88: (2) 58" ANCHORBOLTS OR THREADED ROD.PRESSURE TREATED PORCHPOST. SEE PLAN FOR SIZE &LOCATIONTYP. DBL. 2xTOP PLATETHREADED ROD HOLD DOWNDRILL & EPOXY INTO FTG.PER TYPICAL ANCHORDETAIL BELOWTYPICAL ANCHOR DETAILS7MIN. 3"x3"X 0.229" SQUAREWASHER & NUTFILL ALL HOLES w/ 14" x 2.25"SIMSPON SDS SCREWS,TYP.FASTEN ANCHOR TO FTG.PER TYP. ANCHORDETAIL BELOW2x PT SOLEPLATE, TYPDTT2Z HOLDOWNMIN. 2-PLY STUD GROUP OR3"x3.5" MEMBER SIZEMINIMUM 1/2"THREADED ROD w/ NUTOR HD TITEN ANCHORSILL PLATECORNER 2x FRAMING(2) ROWS OF 10d NAILSAT 8" O.C. INTO TRIPLEGROUP USE 10d NAILS AT8" O.C. FOR STUDGROUPSILL PLATENOTE: ADD (1) ADDITIONAL ROW OF NAILS ATEACH STUD FACE FOR 2X6 & 2X8 FRAMINGDBL. TOP PLATE.FASTEN T/G PERDETAILS, TYP.CORNERSTUDGROUPLAP TOP & BTM. STUDSIN TOP PLATES AT ALLCORNERS. FASTENSTUDS TOGETHER w/(5) 16d NAILSPLANCORNER FRAMING DETAIL6WALLOPENINGBLOCKING LOCATEDUNDER STUDS TOTRANFER ROOF, WALL,OR FLOOR LOADS FROMUPPER STORIESFLOORTRUSSSOLID BLOCKINGUNDER JACK/KING STUDSBANDRIM BOARD ORCONTINUOUSSHEATHINGWALLOPENINGEXT. BEARING WALL FLOOR FRAMING6HEADERBM. PERPLAN,TYP.DTT2Z716" OSB/PLYW. AT3" O.C ALONG ALLEDGES, TYP.BM. TOSUPPORTSw/ (2)MSTA24 OR(2) HTS202x BTM. PLT. P.T.TYP. BOX COLUMN DETAIL10NOTE: ANY FRAMING/SHEATHING WITHIN 6" OFEXIST. GRADE SHALL BE PRESSURE TREATEDPER FBC.DTT2Z38" STUBBIE PERANCHOR DETAILSSTUDS TO TOP PLT.(1) SPH 4/6 OR (2)SDWC15600(1) LTT20B. SEAT1-2" BELOW SLABw/ 12"x7" STUBBIE2 PLY STUD w/ 8dNAILS AT 6" O.C.STAGG 3 PLYSTUD GROUP w/ 8dNAILS AT 6" O.C.STAGG EACH SIDEA.T.R ALTERNATIVE9FASTEN BTM PLATETO END TRUSS w/10d NAILS AT 6" O.C.STAGGARD.FLOOR END TRUSS,SEE TRUSS SHOPDRAWINGS.2x No. 2 SYPDIAGONAL BRACE AT48" O.C. FASTEN TOTRUSSES/TOPPLATES w/ (3) 10DTOE- NIALS EACHEND.FLOOR TRUSS, SEETRUSS SHOPDRAWINGS.PARALLEL FLOOR TRUSS BRACING11STAIRS EXT. WALL FRAMING82X6 AT 16" O.C. ATSTAIR OPENING (MIN.)2X6 AT 16"O.C.(MIN.)RIM BOARD ORTRUSSES, TYP.(3) 2X6 PLATES CONTINUOUS (NO SPLICES) AT STAIR OPENINGTYPICALEXTERIOR WALLFRAMING PERFRAMING PLAN& DETAILSNAIL CONTIN. PLT'sT/G w/ .131"x3" NAILSAT 6" O.C. TOP & BOT.MARTIN ENGINEERING, LLC. 450 STATE ROAD 13 N., #106-387 JACKSONVILLE, FL 32259 904-472-1459 FL C.A# 32027SHEETKEVIN C. MARTIN, PE #80359REVISION-2:REVISION-1:ISSUED:SCALE:DRAWN:DESIGNED:PROJECT #:2018 MARTIN ENGINEERING, LLC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT FROM MARTIN ENGINEERING, LLC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECTDIMENSIONS WITH THE ENGINEER. DIMENSIONS ARE CONSIDERED APPROXIMATE; CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. REVISIONS No.DESCRIPTION DATE NEW SINGLE FAMILY 808 AMBERJACK LANE ATLANTIC BEACH, FL 3223323-1017KCMKCMAS NOTED11/22/23THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON2/16/24USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES FRAMING DETAILS S-66" MAX6" MAX6" MAX6" MAXL-BRACEFASTENED TOTRUSS WEB w/10d NAILS AT 6"O.C.T-BRACE FASTENEDTO TRUSS WEB w/ 10dNAILS AT 6" O.C.T/L TRUSS BRACING3CONTIN. LATERAL RESTRAINT BRACING1. T AND/OR L BRACING MAY BE USED IN LIEU OFCONTIN. LATERAL RESTRAINT BRACING WHERESPECIFIED ON THE TRUSS SHOP DRAWINGSAND/OR TRUSS LAYOUT.2. TO REPLACE (1) ROW OF LATERAL BRACINGINSTALL (1) 2x4 T/L BRACE AT EACH TRUSS WEB.3. TO REPLACE (2) ROWS OF LATERAL BRACINGINSTALL (1) 2x6 T/L BRACE AT EACH TRUSS WEB.4. BRACING MUST MATCH SIZE, SPECIES, ANDGRADE OF WEB MEMBER.2X6 No. 2 SYP BLOCKING FORBRACE ATTACHMENT. FASTENB/T TRUSSES w/ AT TOP CHORDSw/ (3) 10d NAILS EACH ENDFASTEN DIAGONALBRACE TO BLOCKING w/(7) 10d NAILS2x6 No. 2 SYPDIAGONAL BRACE 48"O.C. U.N.O.2x4 No. 2 SYP, 8'-0" LG., LATERALBRACE AT 48" O.C. TYP. FASTENTO EACH TRUSS w/ (3) 10d OR (2)16d NAILS, TYP.2x4 No. 2 SYPOUTLOOKER AT 24" O.C.2x BLOCKING B/TOUTLOOKERS. FASTENTO ROOF DECK & TOPCHORD(TOE-NAILS) w/ 8dNAILS AT 3" O.C.FASTEN OUTLOOKERTO TOP CHORD OFGABLE END TRUSS w/(1) H2.5A CLIP. FILL ALLHOLES w/ 8d NAILS.PLATELINE2x FASCIA FASTENEDTO OUTLOOKERS w/ (2)16d NAILS EACHADD 2x4 T-BRACE TODIAGONAL BRACE w/10d NAILS AT 3" O.C. IFBRACE LENGTHEXCEEDS 8'-0"45° MAXGABLE END TRUSSVERTICALSINSTALL SIMPSON GBCCLIP (2) REQ. AT EACHBRACE.FASTEN BTM. CHORDOF TRUSS TO TOP PLT.w/ 10d NAILS AT 8" O.C.2x4 No. 2 SYPBLOCKING/NAILERS B/TBRACES. FASTEN TOTOP PLATE w/ 10d NAILSAT 8" O.C.DIAGONAL BRACINGLATERAL BRACINGFASTEN SHEATHING TOGABLE END TRUSS PERTRUSS PLANFASTEN (1) MSTA18 AT48" O.C.,TYP.FASTEN (1) MSTA12 AT48" O.C.,TYP.GABLE END BRACING DETAIL2ROOF SHEATHINGPER SHEATHINGLEDGED ONFRAMING PLAN2x4 No. 2 SPFBRACE B/TTRUSSES AT 12"O.C. ON TOP OFWALLFASTEN BRACETO BTM . TRUSSCHORDS w/ (3)10d TOE NAILSFASTEN BRACE TO TOPPLATES w/ (4) 10d NAILSABOVE BRACINGFOR INTERIORSHEAR WALLSONLYPARALLEL TRUSS TO SHEARWALL BRACING4FLOOR SHEATHING PERSHEATHING LEDGED ONFRAMING PLAN2x4 No. 2 SPF BRACE B/TTRUSSES AT 12" O.C. ONTOP OF WALLFASTEN BRACETO BTM . TRUSSCHORDS w/ (4)10d NAILSFASTEN BRACE TOTOP PLATES w/ (4)10d NAILSABOVE BRACING FORINTERIOR SHEAR WALLSONLYROOF TRUSSES,SEE TRUSS PLANSFASTEN 716" MIN. SHEATHINGTO ADJACENT TRUSSES PERSHEARWALL LEGEND FORWALL BELOW, BLOCK ALLEDGESFASTEN ADDITIONAL2x No 2. SYP. PLATETO TOP PLATE w/ 10dNAILS AT 3" O.C.ROOF TRUSSFLOOR TRUSSFASTEN FLOORSHEATHING TOTRUSSES w/ 10dNAILS AT 3" O.C.FASTEN ROOFSHEATHING TOTRUSSES w/ 8dNAILS AT 3" O.C.ROOFSHEATHINGPERSHEATHINGLEDGED ONFRAMING PLANFASTEN BTM.TRUSS CHORDTO TOP PLT. w/10d TOE NAILSAT 3" O.C.ABOVE BRACINGFOR INTERIORSHEAR WALLSONLYROOFTRUSSES, SEETRUSS PLANSFASTEN ROOFSHEATHING TOTRUSSES w/ 8dNAILS AT 3" O.C.ROOF TRUSSFLOORSHEATHING PERSHEATHINGLEDGED ONFRAMING PLANABOVE BRACING FORINTERIOR SHEARWALLS ONLYEXTEND 716" MIN.SHEATHING TO TOPCHORD OF TRUSS.FASTEN PERSHEARWALL LEGENDFOR WALL BELOW,BLOCK ALL EDGESFLOOR TRUSSFASTEN FLOORSHEATHING TOTRUSSES w/ 10dNAILS AT 3" O.C.FASTEN BTM.TRUSS CHORD TOTOP PLT. w/ 10d TOENAILS AT 3" O.C.FLOOR TRUSSES,SEE TRUSS PLANSFLOOR TRUSSES,SEE TRUSS PLANSTRUSSTRUSSMULTI-PLY GIRDERPLAN VIEWTYPICAL BRACING TO GIRDER DETAIL82x4 X 24" LONG w/ 16d NAILSAT 3" O.C. CONNECT EACHBRACE w/(2) 16d NAILS TO 2x42x4 DIAGONAL BRACING2x4 LATERAL BRACING(2) 16d NAILS ATEACH TRUSS, TYP.OPEN FORA/C DUCTTYPICAL CUT STRONGBACK FOR A/C DUCT62X6 LATERAL BRACING @ 8'-0"O.C (STRONGBACK) w/2-10dNAILS EA. TRUSS2X4 SIDE BY SIDE w/(3) 16d NAILSTO EACH TRUSS (TYP.)2X4 CROSS BRACING MEMBERFASTENED TO TRUSSES W/(2) 16d NAILS EACH END (REFERTO TRUSS NOTES AND TRUSSLAYOUT FOR LOCATIONS)2X4 CONT. LATERAL WOODBRACING NAILED TO BOTTOMCHORD MAXIMUM 10'-0"SPACING AND AS REQUIREDBY TRUSS MANUFACTURE(REFER TO TRUSS NOTESAND TRUSS LAYOUT FORLOCATION)DIAGONAL LATERAL BRACING DETAIL7PRE-ENGINEEREDWOOD TRUSS(2) 16d NAILS EACHMEMBER2X4 CONT. LATERAL WOOD BRACINGNAILEDTO BOTTOM CHORD MAXIMUM 10'-0"SPACINGAND AS REQUIRED BY TRUSSMANUFACTURER(REFER TO TRUSS NOTES ANDTRUSS LAYOUTFOR LOCATION)TYPICAL LATERAL BRACE SPLICE5CONVENTIONAL 2-STORY STRAPPING1INSTALL FULL HEIGHTALL-THREAD RODS ONEACH SIDE OF OPENINGBELOW. SEE TYP.ANCHOR DETAILSFLR. TRUSS ORCONVENTIONALFRAMING, SEEROOF FRAMINGPLAN OR TRUSSPLAN FOR SPECS.FLOOR BEAM ORHEADER, SEEFRAMING PLAN FORSIZE & SPECS,TYP.INSTALL (1) CS16 COIL STRAP FROM UPPER STUDS (IN LINEw/ H8 STUD ABOVE) TO HEADER BELOW. FASTEN w. (7) 8dNAILS ON EACH END MIN.INSTALL (1) H8 FROM TOPPLATE TO STUD AT EVERYOTHER STUD OVER HEADEROPENING BELOW, TYP.FASTEN EACH KING STUD TOTOP PLATE w/ (1) SPH4/6/8 ONEACH SIDE OF HEADER, TYP.FLOOR BEAM ORHEADER, SEEFRAMING PLAN FORSIZE & SPECS,TYP.INSTALL (1) CS16 COILSTRAP FROM EACHKING STUD TO FLOORBEAM/ HEADERBELOW. FASTEN w. (7)8d NAILS ON EACHEND MIN.FASTEN HEADER TOJACK STUDS w/ (1)MSTA18 STRAP,TYP.FASTEN JACKS TOKINGS w/ 8d NAILSAT 4" O.C. STAGG.A-ROOF BEARING WALL OVER HEADERB-ROOF BEARING WALL OVER BEAMD-ROOF BEARING OPENING OVER BEAMINSTALL (1) CS16 COIL STRAP FROMUPPER STUDS (IN LINE w/ H8 STUDABOVE) TO HEADER BELOW. FASTENw. (7) 8d NAILS ON EACH END MIN.INSTALL (1) H8 FROM TOP PLATE TO STUD ATEVERY OTHER STUD OVER BEAM BELOW, TYP.INSTALL FULL HEIGHTALL-THREAD RODS ONEACH SIDE OF OPENINGBELOW. SEE TYP.ANCHOR DETAILSFLR. TRUSS ORCONVENTIONALFRAMING, SEEROOF FRAMINGPLAN OR TRUSSPLAN FOR SPECS.MAX O.C. SPACING OF A.T.R.PER FRAMING PLAN & NOTESOPENING VARIESOPENING VARIESINSTALL (1) CS16COIL STRAP FROMEACH KING STUDTO FLOOR BEAM/HEADER BELOW.FASTEN w. (7) 8dNAILS ON EACHEND MIN.FASTEN HEADER TOJACK STUDS w/ (1)MSTA18 STRAP,TYP.FASTEN JACKS TOKINGS w/ 8d NAILSAT 4" O.C. STAGG.FASTEN EACH KINGSTUD TO TOP PLATEw/ (1) SPH4/6/8 ONEACH SIDE OFHEADER, TYP.INSTALL 1-STORYALL-THREAD ROD ONTHIS SIDE OF OPENING.SEE TYP. ANCHORDETAILSC-ROOF BEARING OPENING OVER HEADER BELOWMARTIN ENGINEERING, LLC. 450 STATE ROAD 13 N., #106-387 JACKSONVILLE, FL 32259 904-472-1459 FL C.A# 32027SHEETKEVIN C. MARTIN, PE #80359REVISION-2:REVISION-1:ISSUED:SCALE:DRAWN:DESIGNED:PROJECT #:2018 MARTIN ENGINEERING, LLC. DRAWINGS, WRITTEN MATERIAL, AND DESIGN CONCEPTS SHALL NOT BE USED OR REPRODUCED IN WHOLE OR PART IN ANY FORM OR FORMAT WITHOUT PRIOR WRITTEN CONSENT FROM MARTIN ENGINEERING, LLC. DO NOT SCALE DRAWINGS. USE GIVEN DIMENSIONS ONLY. IF NOT SHOWN, VERIFY CORRECTDIMENSIONS WITH THE ENGINEER. DIMENSIONS ARE CONSIDERED APPROXIMATE; CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. REVISIONS No.DESCRIPTION DATE NEW SINGLE FAMILY 808 AMBERJACK LANE ATLANTIC BEACH, FL 3223323-1017KCMKCMAS NOTED11/22/23THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY KEVIN C. MARTIN, PE ON2/16/24USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES