Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
808 Amberjack Ln RES24-0044 revision 05.28.2024 (Rev)-B
2024-May-20 15:33:59 Right-Suite® Universal 2023 23.0.01 RSU13256 Page 1 ... Const & Roofing\MISC\808 Amberjack Ln(Rev).rup Calc = MJ8 Front Door faces: NE MANKUS2220Job:Manual S Compliance Report 05/20/24Date:Entire House DRSBy: Project Information For: Cooling Equipment Design Conditions °F77.2Entering coil DB:Btuh31435Sensible gain:°F92.8Outdoor design DB: °F63.6Entering coil WB:Btuh8038Latent gain:°F77.0Outdoor design WB: Btuh39473Total gain:°F75.0Indoor design DB: cfm1317Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5042N1+TEM6A0C42H41++TDRModel:TraneManufacturer: cfm1317Actual airflow: % of load92Btuh28870Sensible capacity: % of load106Btuh8490Latent capacity: %77SHR:% of load95Btuh37360Total capacity: Heating Equipment Design Conditions °F68.9Entering coil DB:Btuh30430Heat loss:°F32.5Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 4TWR5042N1+TEM6A0C42H41++TDRModel:TraneManufacturer: cfm1317Actual airflow: °F27Capacity balance:% of load127Btuh38500Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm1317Actual airflow: °F51Temp. rise:% of load86kW7.7Output capacity: Meets all requirements of ACCA Manual S. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-May-20 15:33:59Right-Suite® Universal 2023 23.0.01 RSU13256 Page 1... Const & Roofing\MISC\808 Amberjack Ln(Rev).rup Calc = MJ8 Front Door faces: NE MANKUS2220Job:Project Summary 05/20/24Date:Entire House DRSBy: Project Information For: 808 Amberjack Lane Mankus Residence REVISED Notes: Design Information Jacksonville/Intnl., FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F33 Outside db °F93Inside db °F70 Inside db °F75Design TD °F38 Design TD °F18Daily range MRelative humidity %50Moisture difference gr/lb50 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh21707 Structure Btuh21272Ducts Btuh8723 Ducts Btuh10163Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0(none) (none)Humidification Btuh0Blower Btuh0Piping Btuh0Equipment load Btuh30430 Use manufacturer's data nRate/swing multiplier 0.98InfiltrationEquipment sensible load Btuh30743 Method Latent Cooling Equipment Load SizingDetailedShielding 3 (partial)1Stories Structure Btuh5340Ducts Btuh2698Central vent (0 cfm) Btuh0CoolingHeating(none)22202220Area (ft²) Equipment latent load Btuh80381909219092Volume (ft³)Air changes/hour 00 Equipment Total Load (Sen+Lat)Btuh38781Equiv. AVF (cfm) 00 Req. total capacity at 0.70 SHR ton3.7 Heating Equipment Summary Cooling Equipment Summary Make Trane Make TraneTrade TRANE Trade TRANEModel 4TWR5042N1 Cond 4TWR5042N1AHRI ref 209323533 Coil TEM6A0C42H41++TDRAHRI ref 209323533Efficiency 7.5 HSPF2 Efficiency 11.7 EER2,14.3 SEER2Heating input Sensible cooling Btuh27650Heating output Btuh @ 47°F38500 Latent cooling Btuh11850Temperature rise °F27 Total cooling Btuh39500Actual air flow cfm1317 Actual air flow cfm1317Air flow factor cfm/Btuh0.043 Air flow factor cfm/Btuh0.042Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.80Capacity balance point = 27 °F Backup:Input = 8 kW, Output = 26304 Btuh, 100 AFUE