715 AMBERJACK LN POOL24-0020 -MATERFILE-POOL-ENGINEERINGD D D D V SK OFRR R R J J J J J J J J J R R VE1 ASF1 BD13' MIN UNBLOCKABLE SOFA'S ON DIFFERENT PLANES LT POOL ENCLOSUREPRIMARY BEAM SPANFACE OF SUPER-GUTTER,FASCIA, OR OTHER LOAD CARRYING MEMBER FOOTINGS THAT ARE DESIGNED TO SUPPORT SCREEN ENCLOSURE PRIMARY LOAD CARRYING MEMBERS SHALL BE SIZED PER TABLE OR PER ALUMINUM ENGINEERS REQUIREMENT. FOOTINGS DESIGNED FOR RETAINING ONLY SHALL BE SIZED THE SAME AS NON-PRIMARY LOAD BEARING FOOTINGS. SEE FOOTING DETAIL FOR ADDITIONAL NOTES AND SIZING. OPTIONAL SHEER DECENT WATER FEATURE 8 FT DEEP MAX 3 FT DEEP 9 IN DEEP SUNSHELF BENCH OR LADDER REQUIRED IN DEEP END FOR POOL DEPTHS THAT EXCEED 5'-0" WW1 PROVIDE LANDING OUTSIDE DOOR PER FBCR DECK DRAIN WITH REMOVABLE CAP PITCHED TO NOT HOLD WATER POOL WET DECKS SHALL BE PITCHED 18"- 14" AWAY FROM THE POOL AND TOWARDS A DRAINAGE PATH THAT WILL NOT IMPACT ADJACENT STRUCTURES ADJUSTABLE EYEBALL RETURNS REQUIRED FOR PROPER CIRCULATION BENCH 28" DEPTH MAX ASF2 ASF4 < 24" RETAINING WALL SEE DETAIL < 12" FOOTING SEE DETAIL 8' FREESTANDING WALL SEE DETAIL SD1 36" GUARDRAIL WHERE DECK IS EQUAL TO OR GREATER THAN 30" ABOVE ADJACENT GRADE HANDRAIL REQUIRED FOR 4 OR MORE RISERS SEE DETAIL BASIN STEPS POOL STEPS SEE DETAIL & NOTES FOOTINGS REQUIRED FOR RETAINING WHERE PAVER DECK EXCEEDS 6" FROM ADJACENT GRADE ACCESS PATH HOUSE WALL IF HOUSE WALL IS USED AS BARRIER PROVIDE DOOR AND WINDOW ALARMS PER FBCR BOND ANY METALLIC ITEMS WITHIN 5FT OF POOL WATER SPA POOL SUNKEN PIT PROVIDE POSITIVE PITCH TO DAYLIGHT,SUMP TO DAYLIGHT, OR SUMP WITH PUMP SEE DESIGN SN1 SW1 ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___)___ Ø MF___ Ø MF___ Ø MF5X NOMINALØ M INCG ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) ___ Ø (___) POOL LOAD CENTER INSTALLED PER NEC. FEEDERS SIZED FOR LOAD, CLEARANCE 30"X36" PER NEC REQUIRED LOW VOLTAGE TRANSFORMER LOCATION & CLEARANCE PER NEC SEE POOL LIGHT NICHE DETAIL. PROVIDE CLEARANCES FOR EQUIPMENT PER FBCM & MANUF. SPEC BONDING SYSTEM SHALL BE PROVIDED PER NEC 680. SEE NOTES for ABBREVIATED SUMMARYFEATURE RETURN MANIFOLD FEATURE RETURN BRANCH FILTRATION EQUIPMENT AND PIPING SIZED PER ANSI/APSP/ICC 15A SEE HYDRAULIC DETAILS ORGANIZE EQUIPMENT FOR ACCESS TO SERVICE BACKWASH WASTE EXTENDED TO EXHAUST TO CITY STORM DRAIN VIA DESIGNED DRAINAGE PATH. PROVIDE BACKWASH HOSE LONG ENOUGH TO REACH PATH PROVIDE 1-GFCI PROTECTED RECEPTACLE 6FT MIN AND 20FT MAX AWAY FROM POOL SELF CLOSING, SELF LATCHING GATE WITH LATCH ABOVE 54" 48" PERIMETER BARRIER FENCE OR NATURAL BARRIER TO ENCOMPASS POOL SCREEN ENCLOSURES CAN MEET BARRIER REQUIREMENTS PROVIDING DOOR IS SELF CLOSING, SELF LATCHING AND LATCH IS ABOVE 54" POOL AND SPA WALLS SHALL NOT HAVE PIPING OTHER THAN THE PERPENDICULAR PENETRATIONS WITHIN THE STRUCTURAL WIDTH OF THE SHELL. SPA WALLS ELEVATED GREATER THAN 2FT ABOVE ADJACENT GRADE REQUIRE ADDITIONAL REINFORCEMENT SEE WALL DETAIL ILLUSTRATIONS AND SCHEMATICS IN THIS DETAIL ARE FOR ENGINEERING REFERENCE ONLY. SITE SPECIFIC DESIGNS SHALL BE PROVIDED WITH THIS DOCUMENT THAT INCLUDE; SHAPE, DEPTH, FEATURES, VOLUME, EQUIPMENT SPECIFICATIONS, & SHOW COMPLIANCE WITH ALL CODES AND REFERENCED STANDARDS AS PROVIDED WITHIN THIS DOCUMENT AND CODES AND ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. ALL DECKING SHALL BE NON-SLIP AND NOT PRESENT A TRIPPING HAZARD TYPICAL REFERANCE ILLUSTRATION 1/8" = 1'-0" 8AWG CONTINUES BOND RING PER NEC 680 AL AF R J D D DSK V OF DJ AF AL T PUMP FILTER HEATER SHEER DECENT BUBBLER MULTI-VALVE SKIMMER UNBLOCKABLE SOFA SOFA SOFA CL GEN. LOAD CENTER AUTOMATION VAC OVERFLOW JET RETURN BALL-VALVE DECK DRAIN SUCTION RETURN ELECTRIC FEATURE AIR GUARD BOND WIRE DECK JET AUTO FILL AUTO LEVEL LOW VOLTAGE TRANSFORMER LEGEND UNBLOCKABLE SOFA LIGHT NICHELESS LIGHT SHEET SHEET NAME THIS DOCUMENT IS PROPERTY OF ENGPLANS, LLC. IT IS NOT TO BE REPRODUCED IN WHOLE OR IN PART. IT IS NOT TO BE USED FOR ANY OTHER PROJECT.(C) COPYRIGHT 2018-PRESENT, ENGPLANS LLC.PROJECT NAMESCOTT WALKER PE NO 83270 CONTRACTORPROFESSIONAL ENGINEER SEAL PROJECT ADDRESSDESIGNEROF DATE REV #EngPlans730 123RD AVETREASURE ISLAND, FL 33706727-656-0553WWW. ENGPLANS.COMENG PLANSINTENT/COMPLIANCE/LIMITATIONS INTENT OF DOCUMENT THIS DOCUMENT IS INTENDED TO PROVIDE A PRESCRIBED ENGINEERED DESIGN AND EMPHASIZE APPLICABLE REFERANCE CODES AND STANDARDS FOR POOLS, SPAS, MECHANICAL EQUIPMENT, ACCESSORY STRUCTURES AND THEIR ASSOCIATED FOUNDATIONS, WATER FEATURES, FIRE FEATURES, HARDSCAPES, AND OTHER RELATED AMENITIES. LIMITATIONS DESIGNS WITHIN THIS DOCUMENT ARE LIMITED TO RESIDENTIAL POOLS AND STRUCTURES AS DEFINED WITHIN THE FLORIDA BUILDING CODE. POOLS SHALL BE LIMITED TO 8 FT IN DEPTH. EXCAVATIONS SHALL BE A DISTANCE OF 5 FT OR 45 DEGREES, WHICHEVER LESS FROM ADJACENT STRUCTURES WITHOUT ADDITIONAL SITE SPECIFIC REVIEW FROM THE ENGINEER OF RECORD. STRUCTURES SHALL BE LOCATED OUTSIDE OF THE COASTAL HIGH HAZARD FLOOD AREA, LANDWARD OF THE LiMWA LINE, UNLESS APPROVED BY EOR ON A SUPPLEMENT DOCUMENT. THIS DOCUMENT IS LIMITED TO USE IN FLORIDA ONLY. ENCROACHMENTS, CLEARANCES, OR SPANS WHICH EXCEED THE LIMITATIONS OF THE DESIGN PARAMETERS SHALL BE REVIEWED BY EOR. ASCE 24 - 14 COLMPLIANCE AND LIMITATIONS POOLS IN THIS DOCUMENT ARE DESIGNED PER ASCE 24-14 SECTION 9.6.1 FOR POOLS IN FLOOD HAZARD AREAS OTHER THAN COASTAL HIGH HAZARD AREAS AND COASTAL A ZONES. THE PRESCRIBED INGROUND POOL HAS BEEN DESIGNED TO WITHSTAND ALL FLOOD-RELATED LOADS AND LOAD COMBINATIONS. INGROUND VESSELS WITHIN FLOOD HAZARD AREAS SHALL BE EQUIPMENT WITH A HYDROSTATIC RELIEF VALVE, SEE DETAIL PROVIDED. MECHANICAL EQUIPMENT WITHIN FLOOD HAZARD AREAS SHALL BE ELEVATED TO A HEIGHT PRACTICAL AND ANCHORED TO RESIST FLOTATION OR DISLODGEMENT. FOR POOLS IN COASTAL HIGH HAZARD AREAS, COASTAL A ZONES,AND OTHER HIGH RISK FLOOD HAZARD AREAS PER ASCE 24-14 SECTION 9.6.2 SUPPLEMENT DOCUMENTATION AND APPROVAL MUST BE PROVIDED BY ENGINEER OF RECORD. THE SUPPLEMENT DOCUMENT AND REVIEW WILL CONSIDER THE INDUCED LOADS AND SCOUR ON THE STRUCTURE DUE TO WAVE ACTION AND PROVIDE ADDITIONAL CONSTRUCTION LIMITATIONS. DESIGN DATA SUMMARY THE DESIGN DATA FOR ALL VESSELS AND STRUCTURES HAVE BEEN DESIGNED FOR USE IN ALL JURISDICTIONS IN FLORIDA. DESIGN LOADS ARE AS REFERENCED IN DESIGN DATA UNLESS NOTED OTHERWISE ON SPECIFIC DETAIL ELEMENTS. DESIGN DATA POOLS & MASONRY WALLS: Vult = 185 MPH vasd = 144 MPH EXPOSURE = D RISK CATEGORY = II RIGID STRUCTURE MWFRS CH 29 ANALYSIS MAXIMUM HEIGHT = 10 FT SCREEN STRUCTURES Vult = 160 MPH Vasd = 124 MPH MAXIMUM HEIGHT = 30 FT EXPOSURE = D HORIZONTAL PRESSURES ON WINDWARD SURFACES = 58 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 46 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 16 PSF VERTICAL PRESSURES ON SOLID SURFACES = 60 SOLID ROOF PATIO COVERS FOR RECREATIONAL OUTDOOR LIVING STRUCTURES Vult = 160 MPH Vasd = 124 MPH MAXIMUM HEIGHT = 20 FT EXPOSURE = D MWFRS CH 29 ANALYSIS C&C PER CH 30.6 GUARDS / HANDRAILS PER FBCR TABLE R301.5 DISTRIBUTED HORIZONTAL LIVE LOAD = 200 PLF HORIZONTAL POINT LOAD ON TOPCAP OR 1SF ON INFILL = 50 LBS RETAINING WALLS VERTICAL SURCHARGE LOAD LIVE + DEAD NOT TO EXCEED 75 PLF SOILS ALLOWABLE BEARING = 2KSF SUBGRADE MODULUS = 100 KSF GAMMA DRY = 0.111 KSF GAMMA SAT = 0.175 KSF PHI MAX = 35 DEG CODE AND STANDARD REFERENCES ·2023 FLORIDA BUILDING CODE, BUILDING, EIGHTH EDITION ·2023 FLORIDA BUILDING CODE, RESIDENTIAL, EIGHTH EDITION ·2023 FLORIDA BUILDING CODE, ENERGY CONSERVATION, EIGHTH EDITION ·2023 FLORIDA BUILDING CODE, MECHANICAL, EIGHTH EDITION ·2023 FLORIDA BUILDING CODE, PLUMBING, EIGHTH EDITION ·2023 FLORIDA BUILDING CODE, FUEL GAS, EIGHTH EDITION ·2023 FLORIDA FIRE PREVENTION CODE, EIGHTH EDITION ·2023 FLORIDA ACCESSIBILITY CODE, EIGHTH EDITION ·NFPA 70—20 - NATIONAL ELECTRICAL CODE ·ASCE/SEI 7-22- MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES ·ASCE/SEI 24—2014- FLOOD-RESISTANT DESIGN AND CONSTRUCTION ·FEMA FEMA TB-2—08 FLOOD DAMAGE-RESISTANT MATERIALS REQUIREMENTS ·AAF—20- GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS 2020 ·ACI 318—19 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ·ACI 506R-16 - GUIDE TO SHOTCRETE ·ANSI/APSP/ICC 3—2014 - AMERICAN NATIONAL STANDARD FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS AND SWIM SPAS ·ANSI/APSP/ICC 5—2012(R2022) AMERICAN NATIONAL STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS ·ANSI/PHTA/ICC 7—2020 - AMERICAN NATIONAL STANDARD FOR SUCTION ENTRAPMENT AVOIDANCE IN SWIMMING POOLS, WADING POOLS, SPAS, HOT TUBS AND CATCH BASINS ·ANSI/APSP/ICC/NPC-12 2016 AMERICAN NATIONAL STANDARD FOR THE PLASTERING OF SWIMMING POOLS AND SPAS ·ANSI/PHTA/ICC 15—2021 - AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY WITH ADDENDA A APPROVED JANUARY 9, 2013 ·ANSI/APSP 16—2017 - AMERICAN NATIONAL STANDARD FOR SUCTION OUTLET FITTINGS ASSEMBLIES (SOFA) FOR USE IN POOLS, SPAS, AND HOT TUBS ·ASME A112.19.8 - SUCTION FITTINGS FOR USE IN SWIMMING POOLS, WADING POOLS, SPAS, HOT TUBS, AND WHIRLPOOL BATHTUB APPLIANCES ·ASTM D3787—89 - TEST METHOD FOR BURSTING STRENGTH OF TEXTILES-CONSTANT-RATE-OF-TRAVERSE (CRT) BALL BURST TEST ·ASTM D4086 - STANDARD PRACTICE FOR VISUAL EVALUATION OF METAMERISM ·ASTM D5034—95 - STANDARD TEST METHOD FOR BREAKING STRENGTH AND ELONGATION OF TEXTILE FABRICS (GRAB TEST) ·ASTM E1347 STANDARD TEST METHOD FOR COLOR AND COLOR-DIFFERENCE MEASUREMENT BY TRISTIMULUS COLORIMETRY ·ASTM E1477 - STANDARD TEST METHOD FOR LUMINOUS REFLECTANCE FACTOR OF ACOUSTICAL MATERIALS BY USE OF INTEGRATING-SPHERE REFLECTOMETERS ·ASTM F1346—91(2010) - PERFORMANCE SPECIFICATION FOR SAFETY COVERS AND LABELING REQUIREMENTS FOR ALL COVERS FOR SWIMMING POOLS, SPAS AND HOT TUBS ·ASTM F2208—14 - STANDARD SAFETY SPECIFICATION FOR RESIDENTIAL POOL ALARMS ·ASTM F2286—16 - STANDARD DESIGN AND PERFORMANCE SPECIFICATION FOR REMOVABLE MESH FENCING FOR SWIMMING POOLS, HOT TUBS, AND SPAS ·ASTM F2376—17a - STANDARD PRACTICE FOR CLASSIFICATION, DESIGN, MANUFACTURE, CONSTRUCTION, AND OPERATION OF WATER SLIDE SYSTEMS ·ASTM G53—96 - PRACTICE FOR OPERATING LIGHT-AND WATER-EXPOSURE APPARATUS (FLUORESCENT UV-CONDENSATION TYPE) FOR EXPOSURE OF NONMETALLIC MATERIALS ·CPSC Pub. No. 362 - SAFETY BARRIER GUIDELINES FOR HOME POOLS ·FINA CHG-22 - FINA Handbook 1998—2000 ·FLORIDA CODE 64E FLORIDA ADMINISTRATIVE CODE (SEWAGE DISPOSAL) ·FLORIDA STATUTES ·NSF NSF 50—19 - EQUIPMENT FOR POOLS, SPAS, HOT TUBS, AND OTHER RECREATIONAL WATER FACILITIES ·NSF NSF 60—05 - DRINKING WATER TREATMENT CHEMICALS—HEALTH EFFECTS ·NSF/ANSI 61—2019 - DRINKING WATER SYSTEM COMPONENTS—HEALTH EFFECTS ·UL 2017—2008 - STANDARDS FOR GENERAL-PURPOSE SIGNALING DEVICES AND SYSTEMS— WITH REVISIONS THROUGH MAY 2011 ·A615/A615M—15ae1 - SPECIFICATION FOR DEFORMED AND PLAIN CARBON-STEEL BARS FOR CONCRETE REINFORCEMENT ·ASTM B209-14 - SPECIFICATION FOR ALUMINUM AND ALUMINUM ALLOY STEEL AND PLATE ·ASTM C33/C33M—18 - SPECIFICATION FOR CONCRETE AGGREGATES ·ASTM C90—2016A - SPECIFICATION FOR LOADBEARING CONCRETE MASONRY UNITS ·ASTM C91/C91M—2018 - SPECIFICATION FOR MASONRY CEMENT ·ASTM C94M—2017 - SPECIFICATION FOR READY-MIXED CONCRETE ·ASTM C150/C150M—2018 - SPECIFICATION FOR PORTLAND CEMENT ·ASTM C476—19 - STANDARD SPECIFICATION FOR GROUT FOR MASONRY ·ASTM C926—18B - SPECIFICATION FOR APPLICATION OF PORTLAND CEMENT-BASED PLASTER ·ASTM C933—2018 - SPECIFICATION FOR WELDED WIRE LATH ·ASTM C946—2018 - STANDARD PRACTICE FOR CONSTRUCTION OF DRY-STACKED, SURFACE-BONDED WALLS ·AWC ANSI/AWC PWF—2021 -PERMANENT WOOD FOUNDATION DESIGN SPECIFICATION ·AWPA C1—03 -ALL TIMBER PRODUCTS-PRESERVATIVE TREATMENT BY PRESSURE PROCESSES ·CSA ANSI/CSA/IGSHPA C448 Series-16-DESIGN AND INSTALLATION OF GROUND SOURCE HEAT PUMP SYSTEMS FOR COMMERCIAL AND RESIDENTIAL BUILDINGS ·CSA ASME A112.18.1—2018/CSA B125.1—2018 - PLUMBING SUPPLY FITTINGS ·CSA B64.2—11(R2016) - VACUUM BREAKERS, HOSE CONNECTION TYPE (HCVP) STANDARD SPECIFICATIONEXPIRES 12/31/24MASTERFILEDUVAL COUNTY 1/1/24 1 3 8" 6" 6" STANDARD POOL WALL #3 REBAR 10" O.C. E.W. REINFORCEMENT SAME AS PB1 DETAIL PLASTER COPING VARIES VARIES SHOTCRETE 4000PSI MIN SS1 SUNSHELF DETAIL NTS NON-SLIP PAVER,STONE,OR PRECAST DECK SLOPED AWAY FROM POOL 18" TO 14" PER FOOT COPING SET LEVEL EDGE SHALL HAVE A 18" RADIUS MIN OVERHANG WATERLINE TILE 12" MIN WATERLINE TILE 6" WIDTH MINIMUM. TILE MUST BE APPROVED FOR USE IN POOLS & SPAS BY MANUFACTURER AND INSTALLED PER TCNA STANDARDS FLEXIBLE POLYURETHANE SEALANT TILE TO COPING 12" TO 1 12" LATEX MODIFIED OR POLY-MODIFIED BEDDING MIX INSTALLED PER MANUFACTURER SPECIFICATION LATICRETE 9235, RED GUARD, OR OTHER DAMPPROOFING IS RECOMMENDED UNDER ALL TILE 38" FINE PAVER BASE 3" THICK MIN, MECHANICALLY COMPACTED INSITU SOIL BEHIND POOL WALL SHALL HAVE A MOISTURE INJECTION TREATMENT TO CONSOLIDATE SOILS AND FILL VOIDS PRIOR TO THE INSTALLATION OF THE PAVER BASE MATERIAL CONTINUES 8 AWG BARE COPPER BOND RING 4"-6" BELOW SUBGRADE AND 18"-24" FROM INSIDE POOL WALL 4 UNIFORMLY SPACED 8 AWG STINGERS ATTACHED TO REINFORCING STEEL. CONNECTIONS SHALL BE WITH UL APPROVED BONDING CLAMPS OR SPLIT BOLTS. 2-#3 REBAR CONTINUES IN POOL BEAM #3 REBAR 10" O.C. E.W. WITH 15' MIN OVERLAP #3 REBAR 10 O.C. E.W. WITH 15' MIN OVERLAP 6" THICK 4000PSI MIN SHOT-CRETE POOL WALL APPLIED PER ACI 506 6" THICK 4000PSI MIN SHOTCRETE POOL FLOOR APPLIED PER ACI 506 REBAR CHAIR OR ADOBE TO PROVIDE 3" CLEAR COVER MIN SOILS SHALL HAVE A 3000 PSI MIN BEARING CAPACITY AND INSPECTED BY RESPONSIBLE PERSON IN CHARGE. SEE NOTES FOR REQUIRED LIMITATIONS SURFACE SHALL BE CLEAN OF DEBRIS ACID WASHED AND SATURATED SURFACE DRY BEFORE APPLYING PLASTER PER ANSI/APSP/ICC/NPC-12 PROVIDE 1 12" CLEAR COVER TO INSIDE FACE OF CONCRETE SHELL ALL SPLICES SHALL BE OVERLAPPED 15" MIN. STACKED OR NON-CONTACT SPLICES ARE PREFERRED. NON CONTACT LAP SPLICES SHALL BE SPACED 2 12". 8" 8" 6" RADIUS TYPICAL 4.5" 90° HOOK FLOOR TO WALL PROVIDE A 6" RADIUS BEND PW1 TYPICAL POOL WALL DETAIL NTS 8" 6" STANDARD POOL WALL #3 REBAR 10" O.C. E.W. REINFORCEMENT SAME AS PB1 DETAIL PLASTER COPING 14" MIN 20" MAX SHOTCRETE 4000PSI MIN BENCH OR OTHER MEANS OF EGRESS SHALL BE PROVIDED AT THE DEEP END FOR POOLS DEEPER THAN 5 FT PER FBC454.2.18. DIMENSIONS AND LIMITATIONS SHALL BE PER ANSI/APSP/ICC-5 2011. BENCHED OR OTHER OBSTRUCTIONS SHALL BE PLACED OUTSIDE OF THE REQUIRED MINIMUM DIVING ENVELOPE. BD1 BENCH DETAIL NTS 2-#3 BENT AROUND SKIMMER NOTCH STANDARD POOL WALL STEEL PROVIDE 1 12" C.C. SKIMMER SHALL BE CAST IN-PLACE WITH SHOTCRETE OR POST GROUTED WITH HYDRAULIC CEMENT 15" MIN OVERLAP OF POOL BEAM BARS 15" REBAR EXTENDED BEYOND FORM FOR SKIMMER VAULT. FOR MISSED STEEL EPOXY PIN 3" INTO POOL BEAM WITH SIKA ANCHORFIX-3001 ESR-3608 OR SIMPSON SET-XP. ESR-2508 ANCHORING ADHESIVE 18" TYP. SN1 SKIMMER DETAIL NTS SN2 SKIMMER DETAIL NTS 18" 4" MIN 1-#3 REBAR CONTINUES NON-SHRINK HYDRAULIC CEMENT COLD JOINT SKIMMER SKIMMER TRIM FLANGE OR TILE CD2 CONCRETE DECK TO POOL BEAM DETAIL NTS STANDARD POOL BEAM COPING 12" EXPANSION BOARD BEDDING MIX 4" NOMINAL 3000PSI CONCRETE WET DECK WITH NON-SLIP FINISH 6" X 6" 10GA X 10 GA WWM 3FT AROUND POOL MIN CONCRETE DECKS OUTSIDE THE WET DECK CAN BE FIBER-REMESH ONLY 8 AWG BOND RING CD3 CONCRETE DECK TO POOL BEAM DETAIL NTS STANDARD POOL BEAM 4" NOMINAL 3000PSI CONCRETE WET DECK WITH NON-SLIP FINISH 8 AWG BOND RING SLIP SHEET 60 MILL PLASTIC OR 90LB FELT FLEXIBLE CAULK 6" X 6" 10GA X 10 GA WWM 3FT AROUND POOL MIN CONCRETE DECKS OUTSIDE THE WET DECK CAN BE FIBER-REMESH ONLY CD1 CONCRETE DECK TO POOL BEAM DETAIL NTS STANDARD POOL BEAM PAVER OVERLAY CONCRETE SLAB 12" EXPANSION BOARD BEDDING MIX 8" 8" 6" 1-#3 REBAR 10" O.C. WITH 3" HOOK 1 12" C.C.MIN3" C.C. MIN 3" C.C. 2- #3 REBAR CONTINUES WITH 15" MIN OVERLAPS BOTTOM OF COPING TOP OF POOL BEAM 4 12" LONG 90° HOOK MIN PB1 TYPICAL POOL BEAM NTS WALL / FLOOR PENETRATION DETAIL NTS PVC RETURN PIPE NON-SHRINK HYDRAULIC GROUT ADJUSTABLE CYCOLAC EYEBALL INLET FITTING WITH 34" ORIFICE MIN STANDARD PVC THREADED FITTING WALL OR FLOOR CONCRETE SHELL PLASTER FINISH DAMP-PROOF AREA PRIOR TO PLASTER 8" MAX 3" MAX 8" MIN ABOVE TOP OF COPING4" IN MIN ABOVE GRADE TRANS NICHELESS ILLUMINARY 4'-0" MIN PVC NICHE BONDING RING 8 AWG NICHE BOND WIRE 4" MIN TO LENS IF APPROVED BY MANUF. 18" MINIMUM OTHERWISE1 12" PVC PIPE AND WALL FITTING 8 AWG BOND TO TRANSFORMER AND EQUIPMENT SEAL WITH BASECRETE SEE DAMPPROOFING NOTES FOR DETAILS LOW VOLTAGE UNDERWATER LUMINARIES LEAVE BULB WIRE LONG ENOUGH TO SET ON COPING FOR SERVICE LIGHT TRANSFORMER & NICHE DETAIL NTS 12" MAX 10" NO ADDITIONAL STEPS REQUIRED WHEN POOL DEPTH EXCEEDS 4'-0" 12" MAX 12" MAX TOP AND BOTTOM RISERS MAY VARY IN HEIGHT ALL INTERMEDIATE RISERS SHALL BE UNIFORM 240 IN² AREA EACH TREAD MIN OPTIONAL HANDRAIL SET SOCKETS IN 6" X 6" X 6" 3000PSI CONCRETE CUBE 8AWG BARE COPPER BOND WIRE EACH SOCKET 6" #3 REBAR 10" O.C. E.W. STAIR DETAIL NTS STAIR DIMENSIONS AND PARAMETERS SHALL BE PER ANSI/APSP/ICC-5 7 1 3 1 MAX MAX 2'-9" MIN 6" RADIUS MAX 11° MAX 8" MAX 42" TOP OF WALL LEDGES/FLOOR SLOPES/SHALLOW WATER DEPTH ANSI/APSP/ICC-5 WEIR CAN BE FLAT OR PITCHED EITHER DIRECTION OPTIONAL SEAT #3 REBAR 10" O.C. E.W. 8" 132" MAX STANDARD POOL FLOOR STANDARD SPA FLOOR 1 12" C.C.1 12" C.C. 6" MAX SHOTCRETE 4000PSI MIN POOL SPA48" MAX WW1 SPA WEIR WALL DETAIL NTS POOL FINISH PLUG HYDROSTATIC RELIEF VALVE SUCTION TO PUMPCLEAN WELL GRADED #57 STONE UNBLOCKABLE SINGLE DRAIN OR MULTIPLE DRAIN NETWORK MAY BE USED. ALL SOFA'S SHALL BE IN STRICT COMPLIANCE WITH ANSI/APSP/ICC-16. ALL INSTALLATIONS SHALL BE IN STRICT ACCORDANCE WITH ANSI/APSP/ICC-7. CONFIGURATION SHALL BE PER MANUFACTURER SPECIFICATIONS AND SHALL HAVE A REFERENCED MAX FLOW GREATER THAN THE SPECIFIED PUMPS MAXIMUM FLOW. ONE HYDROSTATIC RELIEF VALVE HAYWARD SP1056 OR EQUIVALENT SHALL BE PROVIDED FOR EACH INDEPENDENT WATER VESSEL. SHOTCRETE SHALL ENCAPSULATE SOFA AND IMMEDIATELY ADJACENT PVC FITTINGS. THE DETAILS BELOW ARE TO SHOW INTENT. DRAINS AND ATTACHMENTS SHALL BE SIZED AND INSTALLED PER MANUFACTURER SPECIFICATIONS SOFA WITH HYDROSTATIC RELIEF CONFIGURATIONS NTS FOR AIR BLOWERS LOCATED MORE THAN 25' FROM DISCHARGE PROVIDE A HARTFORD LOOP WITHIN 10' OF DISCHARGE HARTFORD LOOP DETAIL NTS FROM BLOWER TO OUTLET PVC SIZED PER DESIGN WATER LEVEL SHEET SHEET NAME THIS DOCUMENT IS PROPERTY OF ENGPLANS, LLC. IT IS NOT TO BE REPRODUCED IN WHOLE OR IN PART. IT IS NOT TO BE USED FOR ANY OTHER PROJECT.(C) COPYRIGHT 2018-PRESENT, ENGPLANS LLC.PROJECT NAMESCOTT WALKER PE NO 83270 CONTRACTORPROFESSIONAL ENGINEER SEAL PROJECT ADDRESSDESIGNEROF DATE REV #EngPlans730 123RD AVETREASURE ISLAND, FL 33706727-656-0553WWW. ENGPLANS.COMENG PLANSSTANDARD POOL REINFORCEMENT SHALL BE #3 MAT 10" ON CENTER EACH WAY UNLESS NOTED OTHERWISE ACI 318-19, SECTIONS 8.6.1.1 AND 24.4.3.2 ARE THE REFERENCED CODES THAT ALL ENGINEERS MUST FOLLOW TO DESIGN STRUCTURAL CONCRETE POOL SHELLS. THESE CODES REQUIRE THE RATIO OF DEFORMED SHRINKAGE AND TEMPERATURE REINFORCEMENT AREA TO GROSS CONCRETE AREA SHALL BE GREATER THAN OR EQUAL TO 0.0018. THE FOLLOWING CALCULATION IS TO SHOW THAT THE MINIMUM STEEL SPACING FOR #3 REBAR IN A 6 INCH THICK POOL SHELL SHALL BE 10" O.C. E.W. MINIMUM TO MEET THE SERVICEABILITY REQUIREMENTS. ALL POOL SHELLS REGARDLESS OF DESIGNER SHALL HAVE A REINFORCEMENT MATT OF #3 REBAR SPACED 10" O.C. MAXIMUM. FOR THICKER CONCRETE OR ELEMENTS WITH LOADS THAT ARE LIMITED BY FLEXURAL FORCES CLOSER SPACING OR LARGER REINFORCEMENT BARS MAY BE REQUIRED. ALL REINFORCEMENT IN THIS DOCUMENT SHALL BE #3 REBAR MATT 10" O.C. E.W. UNLESS NOTED OTHERWISE. AREA STEEL PER #3 REBAR = 0.11 IN² AREA OF STEEL REQUIRED FOR 6" THICK CONCRETE = 6 IN X 12 IN X.0018 = 0.130 IN² AREA OF STEEL PROVIDED BY 12" O.C. E.W. LAYOUT = 1212(0.11) = 0.11 IN² (NOT ACCEPTABLE) AREA OF STEEL PROVIDED BY 10" O.C. E.W. LAYOUT = 1210(0.11) = 0.132 IN² STANDARD SPECIFICATIONEXPIRES 12/31/24MASTERFILEDUVAL COUNTY 1/1/24 2 3 3H: 1V MAX _ VARIES, 4" MIN BELOW UNDISTURBED SOIL GRADE DESIGNED FOR SCREEN ENCLOSURE LOADS PAVER OR STONE OVERLAY THIN-SET MORTAR PER MANUF. SPEC. 1" MAX PAVER BASE CRUSHED CONCRETE 38" & FINES MECHANICALLY COMPACTED 3" MIN 3000 PSI CONCRETE MIN. 60 GRADE REBAR PER TABLE MINIMUM RIBBON FOOTING SIZE FOR POOL ENCLOSURE LOADS Vult = 160 mph PRIMARY BEAM SPAN WIDTH (W) HEIGHT (H)REINFORCEMENT 18' 8" 8"1-#5 OR 2-#3 24' 8" 12"2-#5 OR 4-#3 24'10" 10" 2-#5 OR 4-#3 30' 12" 12" 40'12"16" 1. ALUMINUM POOL ENCLOSURE PRIMARY LOAD CARRYING BEAMS ARE GENERALLY THE LARGER SIZE BEAMS THAT EXTEND FROM THE HOUSE ATTACHMENT TO WALL FARTHEST PERPENDICULAR WALL. THE DISTANCE BETWEEN HOUSE ATTACHMENT AND WALL IS TABLE PARAMETER "PRIMARY BEAM SPAN". SEE NOTES ON SPEC. PAGE FOR ADDITIONAL REFERANCE. PANORAMIC VUE DESIGNS MAY NEED ADDITIONAL HOLD DOWNS CONSULT ALUMINUM ENGINEER. 2. FOOTINGS SUPPORTING ALUMINUM ENCLOSURE SIDE WALLS & NON-PRIMARY BEAMS SHALL BE 8" X 8" WIITH 1-#5 REBAR 3. FOOTINGS NOT DESIGNED TO RESIST ENCLOSURE LOADS BUT USED FOR RETAINING & SUPPORT WHERE PAVER IS GREATER THAN 4" ABOVE ADJACENT GRADE SHALL BE 8" X 4" EMBEDMENT INTO UN DISTURBED SOIL WITH 1-#5 REBAR. 4. ALL FOOTINGS ARE LIMITED TO A HEIGHT OF12" ABOVE UN-DISTURBED SOIL. FOR ELEVATIONS HIGHER SEE RETAINING WALL DETAILS. 5. FOOTINGS DESIGNED BY POOL ENCLOSURE ENGINEER SUPERSEDED THE CONSERVATIVE DESIGNED PRESCRIBED HEREIN 12' MAX "H" "W" PRIMARY BEAM SPAN WALL, FASCIA, OR SUPER-GUTTER MECHANICALLY COMPACTED 1500 PSF MIN SUBGRADE COMPACTED CLEAN FILL FOOTINGS SHALL BE STRUCTURALLY INDEPENDENT OF HOUSE AND OTHER ADJACENT FOUNDATIONS.,THEREFORE NOT PINNED TO OTHER FOUNDATIONS. #8AWG BARE COPPER BOND WIRE WITH UL APPROVED CLAMP ANY METALLIC PART IN OR WITHIN 5FT HORIZONTALLY OR 12FT VERTICALLY OF THE POOL WATER MUST BE BONDED. 2-#5 OR 4-#3 2-#5 OR 4-#3PRIMARY BEAMSIDE WALL FOOTING SIZE FOOTING BY TABLE IF DESIGNED FOR SCREEN STRUCTURE TYPICAL POOL ENCLOSURE SUPER GUTTERHOUSE WALL HIP TYPICAL POOL ENCLOSURE ILLUSTRATION NTS FD1 RIBBON FOOTING DETAIL NTS 3' MIN 3' MIN 3' MIN UNBLOCKABLEUNBLOCKABLE SUCTION OUTLET FITTING ASSEMBLIES (SOFA) ANSI/PHTA/ICC 7 SW1 SPA WALL DETAIL NTS 8"-12" 4'-6" MAX 1-#3 REBAR 10" O.C. WITH 3" HOOK - 3" C.C. 2- #3 REBAR CONTINUES WATER LEVEL 2 12" PVC PIPE MAX 4" MIN 34" CLEARANCE MIN PIPE TO REBAR LONGITUDINAL PIPE MUST BE RUN OUTSIDE OF THE 4" STRUCTURAL DEPTH OF SHELL DEE DETAIL FOR PERPENDICULAR PIPE PENETRATIONS STANDARD POOL FLOOR GRADE 2' MAX SHEET SHEET NAME THIS DOCUMENT IS PROPERTY OF ENGPLANS, LLC. IT IS NOT TO BE REPRODUCED IN WHOLE OR IN PART. IT IS NOT TO BE USED FOR ANY OTHER PROJECT.(C) COPYRIGHT 2018-PRESENT, ENGPLANS LLC.PROJECT NAMESCOTT WALKER PE NO 83270 CONTRACTORPROFESSIONAL ENGINEER SEAL PROJECT ADDRESSDESIGNEROF DATE REV #EngPlans730 123RD AVETREASURE ISLAND, FL 33706727-656-0553WWW. ENGPLANS.COMENG PLANSGENERAL NOTES CONTRACTOR RESPONSIBILITIES; THE CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE TO BUILD THE POOL, SPA, & SYSTEM WITHIN THE ENGINEERING STANDARDS, CODES, AND ORDINANCE PRESCRIBED HERE IN. IF THE PROJECT DEVIATES FROM THE PRESCRIBED, CONTACT THE ENGINEER OF RECORD “EOR”. ALL WORK SHALL BE COMPLETED WITHIN PERFORMANCE STANDARDS AND INSPECTED BY THE LOCAL AHJ OR AUTHORIZED THIRD PARTY. THE CONTRACTOR SHALL VERIFY SITE CONDITIONS MEET THE REQUIREMENTS AS REFERANCED OR PRESCRIBED. CONTRACTOR SHALL VERIFY ALL MATERIALS MEET THE MINIMUM PRESCRIBED SPECIFICATIONS. EMPLOYEES, SUB-CONTRACTORS, & CONSULTANTS SHALL BE TRAINED, LICENSED, & INSURED AS APPLICABLE. THE PROJECT SHALL HAVE A RESPONSIBLE PERSON OVERSEEING THE SITE SAFETY, AND OPERATIONS. EACH PHASE SHALL BE DOCUMENTED WITH PHOTOS INCLUDING COMMISSIONING, FILED, AND AVAILABLE TO EOR UPON REQUEST. THE SUBMITTAL OF SEALED ENGINEERING FROM ENGPLANS TO ANY AUTHORITY HAVING JURISDICTIONS SHALL BE A CONTRACTUAL AGREEMENT TO CONSTRUCT PROJECT PURSUANT TO APPLICABLE CODES, ORDINANCES, STANDARDS, & PLANS PROVIDED HEREIN. STANDARD SUMMARY: THIS SECTION SHALL BE USED FOR REFERENCE BUT DOES NOT INCLUDE ALL CODE RELATED DESIGN STANDARDS. GEOTECHNICAL; ·THE EXCAVATION SHALL BE FREE OF DEBRIS AND ORGANICS. ·SOIL COMPRESSIVE STRENGTH SHALL BE EQUAL TO OR GREATER THAN 1500 PSI. ·THE SOILS SHALL HAVE LOW TO MODERATE PLASTICITY WITH PI<28 PER ASTM D4318. ·IT IS RECOMMENDED TO HAVE A GEOTECHNICAL SURVEY OF THE SITE PRIOR TO EXCAVATION. ·POOLS, FOOTINGS OR RETAINING WALLS LOCATED LESS THAN 7'-0” TO A SLOPE EXCEEDING 3:1 SHALL BE REVIEWED AND APPROVED BY LETTER FROM THE EOR. ·EXCAVATIONS LOCATED WITHIN 5'-0” OR 45 DEGREE ANGLE OF REPOSE FROM ADJACENT STRUCTURE SHALL BE REVIEWED BY EOR. ·EXCAVATIONS SHALL BE DEWATERED AS NECESSARY TO PREVENT COLLAPSE. EFFLUENT SHALL BE FILTERED THROUGH A SOCK OR MEDIA THAT WILL RETAIN SOILS FROM ENTERING THE STORM DRAIN SYSTEM. ·EXCAVATIONS, EARTHWORK, AND DEWATERING SHALL NOT AFFECT ADJACENT PROPERTIES. ·OVER EXCAVATED SHELLS SHALL BE FILLED WITH SHOTCRETE NOT FILL MATERIAL. ·SOILS BELOW DECKING SHALL BE MECHANICALLY COMPACTED. ·DISTURBED SOILS INTENDED TO BE COVERED WITH A SOLID ROOF SYSTEM SHALL BE TERMITE TREATED. STRUCTURAL; SHOTCRETE- PNEUMATICALLY APPLIED CONCRETE PER ACI 506.2: ·4000 PSI 28 DAY COMPRESSIVE STRENGTH MIN. ·WATER TO CEMENT RATIO SHALL NOT EXCEED 0.50 PER ACI 318. ·CUTTINGS AND REBOUND SHALL NOT BE INCORPORATED IN WORK PER ACI 506.2. ·NOZZLE OPERATOR SHALL BE CERTIFIED AND SHALL APPLY PER ASC309R. ·CONCRETE SHALL BE CURED PER ACI 308R FOR 7 DAYS AFTER INITIAL SET. ·SHOTCRETE SHALL BE SHOT WITHIN A TEMPERATURE RANGE OF 40°F-95°F. ·TEST PANELS OR CYLINDERS SHALL BE PROVIDED IF REQUIRED BY AHJ CONCRETE CAST IN-PLACE. CONCRETE CAST IN PLACE (POURED): ·SHALL BE 3000 PSI 28 DAY COMPRESSIVE STRENGTH MIN UNLESS NOTED OTHERWISE. ·WATER TO CEMENT RATIO SHALL NOT EXCEED 0.50. ·CONCRETE SLABS SHALL HAVE EXPANSION JOINTS TOOLED IN OR CUT (25% OF SLAB THICKNESS) WITHIN 24HRS OF PLACEMENT, SPACED PER ACI 224R (11.5' O.C. FOR 4” SLABS). ·CONCRETE SHALL BE PLACED WITHIN 90 MIN OF BATCH TIME. ·CONCRETE SHALL BE CURED PER ACI 308R FOR 7 DAYS AFTER INITIAL SET. ·CONCRETE SHALL BE PLACED WITHIN A TEMPERATURE RANGE OF 40°F-95°F. ·SUPER PLASTICIZERS, FLY ASH, AND SILICA FUME MAY BE USED WITH AN ENGINEERED MIX DESIGN. ·CALCIUM CHLORIDE OR OTHER ACCELERATES ARE NOT PERMITTED. ·CYLINDERS SHALL BE PROVIDED IF REQUIRED BY AHJ. ·½” EXPANSION SHOULD BE PLACED WHERE DECKS MEET THE POOL SHELL AND ADJACENT STRUCTURES U.N.O. ·DECKS SHALL DRAIN AWAY FROM THE POOL 18" TO ¼” PER FOOT. DAMPPROOFING, TILE, & PLASTER; ·PENETRATIONS SUCH AS NICHE, SKIMMER, & RETURNS SHALL BE CHIPPED BACK AND SEALED WITH A WATERSTOP AND SEALED WITH BASECRETE OR EQUIVALENT ACRYLIC EMULSION. ·IT IS RECOMMENDED TO USE A COLLOIDAL SILICATE SPRAY OVER HARDENED POOL SHELL. ·IT IS HIGHLY RECOMMENDED TO USE AN ELASTOMERIC COAT LATICRETE 9235 OR EQUIV. FOLLOWED BY A MODIFIED CEMENTITIOUS COAT UNDER TILED SURFACES AND ELEVATED POOL WALLS. TILE AND GROUT SHOULD BE APPROVED FOR USE IN POOLS BY MANUF. ·TILE INSTALLATION SHALL BE PER THE TILE COUNCIL OF NORTH AMERICA. ·THE SEAM BETWEEN THE COPING AND WATERLINE TILE SHALL BE SEALD WITH A FLEXIBLE ACRYLIC POLYMER SEALANT. ·POOL SHELL SHALL BE CLEAN AND SURFACE SATURATED DRY PRIOR TO PLASTERING. ·PLASTER SHALL BE INSTALLED 3/8” TO ¾” THICKNESS. ·DO NOT ADD SALT FOR 30 DAYS AFTER PLASTER. REINFORCING STEEL; ·ALL REBAR SHALL BE 60KSI STAMPED PER ASTM A615 3-S-60 U.N.O. ·LAP SPLICES SHALL BE NON-CONTACT SPLICES WITH BARS SEPARATED 6db OR 2.5” WHICHEVER IS GREATER. ·CONTACT LAP SPICES SHALL BE STACKED TO REDUCE SHADOWING. ·WELDED WIRE MESH (WWM) 6X6XW1.4XW1.4 SHALL BE USED U.N.O. ·STEEL REBAR SHALL BE PLAIN AND NOT EPOXY COATED. ·POOLS, DECKS, & RETAINING WALLS SHALL BE STRUCTURALLY INDEPENDENT OF THE HOUSE OR STRUCTURE. REBAR SHALL NOT BE PINNED TO HOUSE U.N.O. ·REBAR SHALL BE SECURED WITH CLIPS, TIES, CHAIRS, AND ADOBE TO MAINTAIN THE REQUIRED CLEAR COVER DISTANCES PER ACI 318 DURING THE SHOOTING PROCESS. ·THE POOL SHELL SHALL HAVE A CLEAR COVER DISTANCE OF 3” CAST AGAINST EARTH AND 1 ½” OTHERWISE. ·BARS SHALL BE PLACED WITH A TOLERANCE OF 3/8”. HYDRAULICS; ·PROOF OF COMPLIANCE WITH ANSI/PHTA/ICC - 7 SUCTION ENTRAPMENT AVOIDANCE SHALL BE PROVIDED TO OWNER AND AHJ. THE MAXIMUM SYSTEM FLOW CAPACITY SHALL BE TESTED BY CONTRACTOR DURING COMMISSIONING TO VERIFY COMPLIANCE. . ·SUCTION FITTING OUTLET ASSEMBLY (SOFA) SHALL BE TESTED AND COMPLIANT PER ANSI/PHTA/ICC - 16. ·SYSTEM SHALL BE SIZED SO WATER VELOCITY IN PIPES DOES NOT EXCEED 6 FPS SUCTION & 8 FPS RETURN. ·FILTERS SHALL BE SIZED BY DIVIDING THE MAXIMUM PUMP FLOW BY THE FILTER FACTOR; ·· CARTRIDGE = 0.375 ··SAND = 15 ··D.E. = 2 ·PROOF OF COMPLIANCE WITH ANSI/PHTA/ICC -15 RESIDENTIAL SWIMMING POOL & SPA ENERGY CODE SHALL BE PROVIDED TO OWNER & AHJ. ·HYDROSTATIC RELIEF VALVE SHALL BE INSTALLED AS PRESCRIBED PER FBC4501.21.4. ·18” OF STRAIGHT PIPE SHALL BE PROVIDED BETWEEN PUMP AND HEATER FOR FUTURE SOLAR, THERE MUST BE A SECTION OF STRAIGHT PIPE BEFORE PUMP GREATER THAN OR EQUAL TO 4 PIPE DIAMETERS. ·EQUIPMENT, PIPING, & SYSTEM PERFORMANCE SHALL BE IN COMPLIANCE WITH THE ABOVE STATED AS A MINIMUM. MORE EFFICIENT EQUIPMENT AND LARGER PIPE SIZES PROVIDE OPTIMUM SYSTEM PERFORMANCE. ·SKIMMER EQUALIZER LINES ARE PROHIBITED ·POOLS WITH A WEIR EXHAUSTING TO A COLLECTOR TANK SHALL BE INDIVIDUALLY DESIGNED & APPROVED BY EOR. ·SANITIZING AND FILTRATION EQUIPMENT SHALL BE SIZED BY CONTRACTOR TO MEET ANSI/PHTA/ICC - 11 REQUIREMENTS. ·ALL POOL PIPE SHALL BE ASTM D1785 SCH 40 OR 80. ·ALL FITTINGS SHALL BE ASTM D2455 SCH 40 OR 80 TO MATCH PIPE. ·SCHEDULE 40 PIPE SHALL NEVER BE TAPPED. ·FLEX PVC PIPE IS NOT PERMITTED. ·ALL POOL PIPES SHALL BE PRESSURE TESTED AT A MINIMUM OF 35PSI FOR 15 MIN PER R4501.12. ·PIPES MAY NOT BE INSTALLED IN THE STRUCTURAL WIDTH OF WALLS OR FLOORS U.N.O. ·MAXIMUM PUMP FLOW SHALL NOT EXCEED EQUIPMENT MAXIMUMS SUCH AS FILTERS, HEATERS & CHLORINATORS. ·AUTO FILL DEVICES SHALL BE INDEPENDENT OF POTABLE WATER BY USE OF An AIR GAP OR RATED RPZ DEVICE. ·BACKWASH WASTEWATER PER R4501.10 SHALL BE DIRECTED TOWARDS STORM DRAINS OVER EXISTING DRAINAGE PATHS AS TO NOT IMPACT ADJACENT PROPERTIES. ·ONE SKIMMER PER 800 SF OF SURFACE AREA SHALL BE PROVIDED. ELECTRICAL; ·SHALL COMPLY WITH NFPA 70-20. ·ASCE 24-14 SECTION 9.6 AND CHAPTER 7 AS APPLICABLE ·ASCE 24-14 SECTION 7.2.5 FOR INSTALLATIONS BELOW DFE ·BONDING PER ARTICLE 680 ·EQUIPOTENTIAL BONDING OF PERIMETER SURFACE WITH AN 8 AWG BARE SOLID COPPER FOLLOWING THE CONTOUR OF THE PERIMETER SURFACE, LOCATED BETWEEN 18” AND 24” FROM THE INSIDE WALLS OF THE POOL AT A DEPTH OF 4” -6” UNDER THE DECK SUBGRADE. ·CONCRETE DECKS THAT EXTEND 3' MIN FROM POOL WATER AND ARE REINFORCED WITH A MINIMUM OF #3 REBAR 12” O.C. E.W. MAY BE USED INLEAU OF A BONDING RING. ·THE BOND RING SHALL BE ATTACHED TO THE POOL SHELL STEEL REINFORCEMENT WITH 4 UNIFORMLY SPACED 8 AWG BARE SOLID COPPER WIRE WITH UL APPROVED CONNECTORS. ·ANY METALLIC PART IN OR WITHIN 5FT HORIZONTALLY OR 12FT VERTICALLY OF THE POOL WATER MUST BE BONDED. LINE VOLTAGE & CLEARANCE ·PROVIDE A SPACE 30” WIDE AND 36” DEEP FROM ANY ELECTRICAL DISTRIBUTION PANEL PER 110.26 ·REFER TO NEC TABLE 300.5 FOR MINIMUM COVER REQUIREMENTS FOR BURRIED CONDUCTORS ·WATER PIPES ARE NOT ALLOWED TO PASS OVER A PANEL, DISCONNECT, TRANSFORMER, OR OTHER ELECTRICAL EQUIPMENT PER NEC 110.26 ·NEMA 3R ENCLOSURES SHALL BE USED OUTSIDE ·LOW VOLTAGE SHALL NOT BE IN THE SAME CONDUIT AS LINE VOLTAGE CONDUCTORS ·OVERHEAD CONDUCTOR CLEARANCES SHALL BE PROVIDED PER NEC TABLE 680.9 ·A DISCONNECTING MEANS FOR EQUIPMENT SHALL BE READILY AVAILABLE WITHIN EYE SIGHT OF EQUIPMENT AND MORE THEN 5FT FROM POOL. ·RECEPTACLES SHALL BE GFCI PROTECTED AND NOT BE LOCATED LESS THAN 6FT FROM POOL. ·ONE GFCI RECEPTACLE MUST BE LOCATED 6FT-20FT HORIZONTALLY FROM POOL. ·LIGHTS AND FANS SHALL NOT BE WITHIN 12' VERTICALLY OR 5' HORIZONTALLY. ·UNDERWATER LIGHTING JUNCTION BOX OR TRANSFORMER SHALL BE A MINIMUM OF 4FT AWAY FROM POOL AND 4IN ABOVE GROUND OR 8IN ABOVE MAX WATER LEVEL WHICHEVER PROVIDES GREATER ELEVATION. ·POOL SUB-PANEL SHALL BE SIZED FOR THE INTENDED LOAD ·6-13 LUMENS/SF OF UNDERWATER LIGHT IS RECOMMENDED ·LUMINARIES SHALL HAVE ENOUGH SERVICE CORD TO BE REMOVED FROM NICHE AND PLACED ON DECK FOR SERVICE. ·UNDERWATER LUMINARIES SHALL BE SUBMERGED 18” UNLESS RATED BY MANUF. BUT NOT LESS THAN 40. ·UNDERWATER LIGHT NICHE SHALL BE BONDED. ·LISTED LOW VOLTAGE LANDSCAPE LIGHTS SHALL HAVE MINIMUM CLEARANCE FROM WATERS EDGE OF 5 FT. ·IT IS RECOMMENDED TO HAVE 3 FOOT-CANDLES OF ILLUMINATION AT THE POOL WATER SURFACE AND WET DECK. SAFETY BARRIERS; ·OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER COMPLYING WITH R4501.17.1.1 THROUGH R4501.17.1.14. ·TOP OF THE BARRIER SHALL BE 48 INCHES ABOVE GRADE MEASURED ON THE SIDE THAT FACES AWAY FROM THE SWINGING POOL. ·THE MAX VERTICAL CLEARANCE BETWEEN THE BOTTOM OF THE BARRIER AND THE TOP OF THE GROUND SHALL BE 2 INCHES. ·THE BARRIER SHALL HAVE OPENINGS THAT REJECT PASSAGE OF A 4 INCH SPHERE. ·MAXIMUM MESH OF A CHAIN LINK FENCE SHALL BE 2 14". ·ACCESS GATES SHALL BE SELF-CLOSING AND SELF-LATCHING WITH THE RELEASE DEVICE LOCATED ABOVE 54" FROM THE BOTTOM OF THE GATE. ·DWELLINGS THAT SERVE AS BARRIERS SHALL HAVE ALARMS OR BARRIERS PER FBC R4501.17.1.9. ·SCREEN ENCLOSURES WHICH ACT AS BARRIERS SHALL HAVE SELF-CLOSING & SELF-LATCHING DOORS WITH A LATCH LOCATED ABOVE 54". ANIMAL ACCESS DOORS ARE NOT PERMITTED. ·MESH SAFETY BARRIER SHALL MEET THE REQUIREMENTS OF FBC4501.17.1.15. ·FINAL ELECTRICAL AND BARRIER INSPECTIONS MUST BE APPROVED PRIOR TO FILLING WITH WATER. CHEMICAL STORAGE ·WARNING: IN-PROPER STORAGE OF POOL CHEMICALS CAN CAUSE FIRES, BODY INJURY, AND DEATH. ·CHEMICALS SHALL BE STORED PER NFPA-400 (FREE STANDARD AVAILABLE AT WWW.NFPA.ORG). STANDARD SPECIFICATIONEXPIRES 12/31/24MASTERFILEDUVAL COUNTY 1/1/24 3 3