715 AMBERJACK LN POOL24-0020 Taylor-24016 TDHSwimming Pool Energy Efficiency Compliance Information
NOTE: These Requirements Apply ONLY to the Filtration Pump
ANSI / APSP / ICC WORKSHEET 2020 Determine Pipe Sizes
Branch Pipe NA "to keep velocity @ 6fps max at NA gpm System Flow Rate
Flow Claculations:
Pool Volume:335 x 4.00 x 7.48 =10023 /360 =27.84 36 Trunk & Suction 2.5 "to keep velocity @ 6 fps max at 88 gpm System Flow Rate
Surf Area Avg Depth Gal/Cub Ft Vol. in Gal Turnover Calc *Filtration
in Min Flow Rate Flow Rate Return Pipe 2 "to keep velocity @ 8fps max at 82 gpm System Flow Rate
*Note: for pools under 13,000 gal the calculated flow rate or 36gpm whichever is greater = the filtration flow rate
Auxiliary Load NA NA =NA Pump Selection As listed on Curve
Yes/No Description Calculated Auxillary flow Rate Filtration Pump A Max Flow Rate 97 Pump Description
Flow Rate (Low Speed)32 @ 1725 GPM Hayward Tristar
GPM RPM MD Cover A&A AVSC 1.85 hp Var Speed
Min Suction Side Pipe Size @6 fps 2.5 "Min Suction Side Branch Pipe @ 6fps NA "Determine the number and type of required in-floor suction outlets:
Min Return Side Pipe Size @8 fps 2 "Min Return Side Branch Pipe @ 8fps NA "Multiple suction outlets @ 146 gpm max. flow
Determine Filter Size:Main 1 A&A AVSC channel drain @ 196 gpm w/1 ports
Filtor Factors (GPM/SF)0.375 2 15
Cartridge DE Sand FLOW & FRICTION LOSS PER FOOT
Schedule 40 PVC Pipe
Filter Size:36.00 /0.375 =96.00 Hayward 225
Flow Rate Filter Factor Filter size Filter Make and Model Pipe Size
From Auxiliary Load Calculation, if applicable 1"16 gpm .014'21 gpm .023'26 gpm .35'
Pump Controls:1.5"37gpm .08'50 gpm .14'62 gpm .21'
Control System Hayward Omni PL 2"62 gpm .06'82 gpm .10'103 gpm .16'
Control System Make and Model 2.5"88 gpm .05'117 gpm .09'146 gpm .13'
3"136 gpm .04'181 gpm .07'227 gpm .10'
X Filtration pump with no auxiliary load may have standard time clock 4"234 gpm .03'313 gpm .05'392 gpm .07'
6"534 gpm .02'712 gpm .03'
NA Filtration pump with auxiliary load must have a control system for
low speed default within 24 hours TDH Calculation Options For Each Pump
Heater Model Hayward 105 BTU Electric Heat Pump Hayward BHP31204T 120K/50K H/C X Simplified Total Dynamic Head (STDH)
105 BTU Electric BHP31204T 120K/50K H/C Complete STDH Worksheet - Fill in all blanks
Total Dynamic Head (TDH)
Gas Heater Efficiency Rating 84%No pilot Light Heat Pump Efficiency COP 5.0/3.8 Complete Program or other calcs. Fill in
required blanks on worksheet & attach
Maximum Flow Capacity
ANSI /APSPt 7, 2020 Compliance Work Sheet of the new or replacement pump
Determine Simplified TDH Owner Info:
Distance from pool to pump in feet:49
Job Taylor
Suction Pipe Friction loss in 2.5 "pipe per 1' @ 88 =0.05 pipeflow/friction loss
gpm Name Ken Taylor
Return Pipe Friction loss in 2 "pipe per 1' @ 82 =0.10 pipeflow/friction loss
gpm
Address 715 amberjack Lane
Suction TDH 49 x 0.05 =2.45 TDH in Piping 7.35
Length Ft of head per 1'TDH Filter loss in TDH - +
+Heater loss in TDH - `
Return TDH 49 x 0.10 =4.90 Other loss in TDH 7.00 +
Ft of head per 1'TDH =Total Simplified TDH 14.35 =Atlantic beach
SP3202VSP
Velocity - Feet Per Second
6 FPS 8 FPS 10 FPS
2375 St Johns Bluff Rd S #201
CPC 1460073
Jacksonville, FL 32246
Phone: 904.620.0090
Fax: 904.620.0206
Contractor
Marc Mihalsky
Contractors License No.