1889 Atlantic Beach Dr POOL24-0025 PermitOWNER:ADDRESS:CITY:STATE:ZIP: Scott Bannwart 1889 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: POOLS BY JOHN CLARKSON, INC.600 ST JOHNS BLUFF RD JACKSONVILLE FL 32225 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1575 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1889 ATLANTIC BEACH DR SWIMMING POOL SWIMMING POOL RESIDENTIAL PRIVATE PROVIDER - inground swimming pool $89175.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 3Issued Date: 7/30/2024 PERMIT NUMBER POOL24-0025 ISSUED: 7/30/2024 EXPIRES: 1/26/2025 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 3 PUBLIC WORKS POST CONSTRUCTION TOPO SURVEY INFORMATIONAL Notes: If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 4 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL Notes: Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon). 5 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. 6 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. Full site to be grassed. 7 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 8 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 9 PUBLIC WORKS DOCUMENT IMPERVIOUS AREA INFORMATIONAL Notes: Strongly suggest thorough documentation of impervious areas be recorded. 10 PUBLIC WORKS TOPO SURVEY INFORMATIONAL Notes: Must provide a topographic (TOPO) survey with water retention for final C.O. Inspection. 11 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 12 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 2 of 3Issued Date: 7/30/2024 PERMIT NUMBER POOL24-0025 ISSUED: 7/30/2024 EXPIRES: 1/26/2025 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $440.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $220.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $10.65 STATE DCA SURCHARGE 455-0000-208-0600 0 $7.10 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $927.75 13 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 14 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 3 of 3Issued Date: 7/30/2024 PERMIT NUMBER POOL24-0025 ISSUED: 7/30/2024 EXPIRES: 1/26/2025 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $927.75 POOL24-0025 Address: 1889 ATLANTIC BEACH DR APN: 169505 1575 $927.75 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $440.00 BUILDING PERMIT 455-0000-322-1000 0 $440.00 BUILDING PLAN REVIEW $220.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $220.00 PUBLIC WORKS PLAN REVIEW $100.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE SURCHARGES $17.75 STATE DBPR SURCHARGE 455-0000-208-0700 0 $10.65 STATE DCA SURCHARGE 455-0000-208-0600 0 $7.10 ZONING PLAN REVIEW $100.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL FEES PAID BY RECEIPT: R27739 $927.75 Printed: Tuesday, July 30, 2024 3:48 PM Date Paid: Tuesday, July 30, 2024 Paid By: POOLS BY JOHN CLARKSON, INC. Pay Method: CREDIT CARD 10064867259 1 of 1 Cashier: KW Cash Register Receipt City of Atlantic Beach Receipt Number R27739 5' 1"P/E LOCATION 80' TO MAIN DRAIN 6'10' 6"93' 6 " 35' Existing: Total Lot: 10880SF House: 3260 SF Lanai: 288 SF Front Porch: 40 SF Driveway/Walk: 636 SF A/C Pad: 10 SF Total: 4234 SF ISR:38.9% Proposed: Total Lot: 10880 SF House: 3260 SF Lanai: 288 SF Front Porch: 40 SF Driveway/Walk: 636 SF A/C Pad: 10 SF P/E Pad: 18 SF 50% Pool/Coping: 203 SF Pool Deck: 593 SF Total: 5048 SF ISR:46.4% COPING: 10.0 Revision Request/Correction to Comments ••ALL HIGHLIGHTED INFORMATIONINCity of Atlantic Beach Building Department GRAY ts REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT g:POOL24-0025 Revision to Issued Permit OR Corrections to Comments Date 7/17/2024 Project Address:1889 Atlantic Beach Dr. Contractor/Contact Name:Pools by John Clarkson/ Debbi Werling Contact Phone:904-223-4050 Email:debbi@pbjc.com Description of Proposed Revision / Corrections: Notated and corrected patio/deck to be at least 5 feet from lot lines Debbi Werling (Printed name) affirm the revision/correction to comments is inclusive of the proposed changes. • Will proposed revision/corrections add additional square footage to original submittal? No C] Yes (additional s.f. to be added : • Will proposed revision/corrections add additional increase in building value to original submittal? O*Yes (additional increase in buildi value: $(Contractor must sign if increase in valuation) *Signature of Contractor/Agent: Approved Denied Revision/Plan Review Comments Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services (Office Use Only) Not Applicable to Department Permit Fee Due $ Reviewed By Date Updated 10/17/18 5' 1"P/E LOCATION 80' TO MAIN DRAIN 6'10' 6"93' 6 " 35' Existing: Total Lot: 10880SF House: 3260 SF Lanai: 288 SF Front Porch: 40 SF Driveway/Walk: 636 SF A/C Pad: 10 SF Total: 4234 SF ISR:38.9% Proposed: Total Lot: 10880 SF House: 3260 SF Lanai: 288 SF Front Porch: 40 SF Driveway/Walk: 636 SF A/C Pad: 10 SF P/E Pad: 18 SF 50% Pool/Coping: 203 SF Pool Deck: 593 SF Total: 5048 SF ISR:46.4% COPING: 10.0 Revision Request/Correction to Comments ••ALL HIGHLIGHTED INFORMATIONINCity of Atlantic Beach Building Department GRAY ts REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT g:POOL24-0025 Revision to Issued Permit OR Corrections to Comments Date 7/17/2024 Project Address:1889 Atlantic Beach Dr. Contractor/Contact Name:Pools by John Clarkson/ Debbi Werling Contact Phone:904-223-4050 Email:debbi@pbjc.com Description of Proposed Revision / Corrections: Notated and corrected patio/deck to be at least 5 feet from lot lines Debbi Werling (Printed name) affirm the revision/correction to comments is inclusive of the proposed changes. • Will proposed revision/corrections add additional square footage to original submittal? No C] Yes (additional s.f. to be added : • Will proposed revision/corrections add additional increase in building value to original submittal? O*Yes (additional increase in buildi value: $(Contractor must sign if increase in valuation) *Signature of Contractor/Agent: Approved Denied Revision/Plan Review Comments Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services (Office Use Only) Not Applicable to Department Permit Fee Due $ Reviewed By Date Updated 10/17/18 004-022-7464-00 Rev01 Publish110719 The World’s #1 In-Floor Cleaning Systems Company 1Paramount.com | 1.800.621.5886 SDX2 - THE HIGH PERFORMANCE SAFETY DRAIN BECAUSE POOL SAFETY IS ALWAYS PARAMOUNT. SDX2 is a high flow suction outlet suitable for use as a wall fitting, or as a floor fitting when debris removal is not a concern. Available for concrete, vinyl and fiberglass pools, SDX2 performs at a very high flow rate while operating at one of the lowest velocity ratings in the industry. SDX2 boasts a flow rating of 188 gpm on the floor and 154 gpm on the wall. FEATURES AND BENEFITS • NO SUMP REQUIRED = TIME SAVED. No need to field fabricate a sump to meet the ‘1.5 times the pipe diameter’ requirement. • Low velocity 1.396 feet per second at the maximum (188 gpm) flow rating. • Patented ribbed design achieves very high flow via 60 independent flow partitions. • Approved as a bulkhead fitting as the safety is in the cover and back plate. • Anti-vortex center shield blocks contact with direction suction. • SDX2 comes with a plaster ring for new applications. • SDX2 Retro comes with adaptable back plate to retrofit suction fittings up to 10” in diameter. • Great for use with water features. • Life in years = 5 years installed • Available in colors to complement any interior surface MEETS NATIONAL ANTI-ENTRAPMENT REQUIREMENTS VGB 2008 Compliant. ANSI/APSP- 16 2011 • Tested by IAPMO R&T Lab, an ANAB accredited testing laboratory and certified by IAPMO R&T, an ANSI accredited certification body • USPC (uniform swimming pool, spa and hot tub code) compliant • IRC (International Residential Code), section 106.2 suction fittings – compliant # drains Maximum Flow: Floor Maximum Flow: Wall 1 SDX2 drain 188 GPM (711 LPM)154 GPM (582 LPM) 2 SDX2 drains 188 GPM (711 LPM)154 GPM (582 LPM) 3 SDX2 drains 282 GPM (1066 LPM)231 GPM (873 LPM) 4 SDX2 drains 376 GPM (1422 LPM)308 GPM (1164 LPM) WARNING: SDX2 and SDX2 Retro must be installed in accordance with Paramount’s written instruction manual, and in conformity with applicable Federal, State, Local and Swimming pool industry building and safety codes. US and Foreign patents and patents pending see www.1paramount.com/about/patents/“VGB 2008” COMPLIAN T NSF/ANSI 50SDX2 RETRO Eliminates the need to chisel out a sump SDX2 CONCRETE For new construction or remodel SDX2 VINYL No sump required 9" 10 3/8" 11 5/8" Bolt Holes,Center to Center 11 5/8" 15 1/4" 14" 30 1/8" Front Edge of Pumpto Center of Bolt Holes 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM) VSSHP220DV2A Performance Curves 600 RPM 1200 RPM 1730 RPM 2400 RPM 2800 RPM 115VAC3000 RPM 3450 RPM 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200Total Dynamic Head (Feet of Water)Flow Rate, Gallons Per Minute (GPM) VSSHP270DV2A Performance Curves 600 RPM 1200 RPM 1730 RPM 2400 RPM 2800 RPM 115VAC3000 RPM 3450 RPM 1Based on a 28,000 gallonpool with 2 turnovers per day at an average power cost of 0.195/kWh; when tested in accordance with the applicable requirements of 10 CFR 429. 2Compared to previous generation ePump based on independent third-party lab testing at 1725 RPM from 6 ft. 3 R-Kit R0446102 includes two unions, O-rings and 2.5” x 3” tailpieces. 4 WEF = weighted energy factor in kgal/kWh. WEF is a performance-based metric adopted by the Department of Energy to characterize the energy performance of dedicated-purpose pool pumps. Department of Energy 10 CFR Parts 429 and 431. 5Always follow local building and safety codes for pipe sizing and guidelines. The Jandy® ePump™ is designed for energy savings, efficient operation and easy maintenance. When building a high-end pool, you want a high-end pump. The ePump is a high-performance, low-maintenance, energy-saving variable-speed pool pump, in a large-sized body. • Maximum SavingsSave over $1,1001 per year in energy costs! The ePump allows for dramatic energy savings compared to high energy consuming single-speed pumps. • Improved Performance, Reduced Maintenance Small pump baskets fill faster — restricting flow and eroding performance. The ePump features the largest capacity smooth surface basket in the industry for reduced maintenance and improved performance. • 70% Quieter Operation2 Relax and unwind without the unwanted sound of a pool pump. Proprietary sound dampening motor technology provides almost "whisper-quiet" pump operation — no louder than the daily operation of your refrigerator — allowing you to enjoy a truly peaceful pool experience. • Maximum ConvenienceTwo auxiliary relays enable instant automation for your pump — plus two additional pieces of equipment — such as a booster pump or salt chlorinator. • Multiple Control Options Programmable and customizable control options with Jandy AquaLink® automation systems, iQPUMP01, or the JEP-R controller (controller sold separately). • No Rewiring NecessaryAuto-sensing dual voltage motor automatically recognizes and adapts to 115 or 230-volt power supplies. • Additional Features ›Available in 2.2 and 2.7 HP models ›RS485 Quick Connect Port for faster installation and maintenance ›Dry contact relay control ›Easy controller setup auto detects connection to an automation system or a traditional controller, eliminating the need to adjust settings manually ›2" x 2.5" unions included / 2.5" x 3" compatible3 ›Ergonomic carry handle for easy installation ›Tool free lid allows for quick and easy cleaning of the pump basket ›Zero Clearance Totally Enclosed Fan-Cooled (TEFC) permanent magnet brushless DC motor that provides cooler operation and extended motor life Jandy.com | 1.800.822.7933 ©2021 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks are the property of their respective owners. 1765_SL Model No.THP WEF4 Voltage Max Watts Amps Union Size Rec. Pipe Size5 Carton Weight Overall Length VSSHP220DV2A 2.21 8.58.8 230 VAC115 VAC 2,190W1,660W 10.516.0 2" × 2 1/2"2" – 3"71 lbs.30 1/8" VSSHP270DV2A 2.70 7.59.3 230 VAC115 VAC 2,370W1,675W 10.516.0 2" × 2 1/2"2" – 3"71 lbs.30 1/8" DIMENSIONS SPECIFICATIONS PERFORMANCE ©2011 Zodiac Pool Systems, Inc. SA6259 0611 ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.® is a registered trademark of Zodiac International, S.A.S.U., used under license.® www.ZodiacPoolSystems.com Technical Specifications CS Series Filters Part No. Description Size CS100 CS Cartridge Filter 100 Sq. Ft. CS150 CS Cartridge Filter 150 Sq. Ft. CS200 CS Cartridge Filter 200 Sq. Ft. CS250 CS Cartridge Filter 250 Sq. Ft. 143/3/34/4/" 31/4/4/" 181/2/2/" ‘A’ 0 2 4 6 8 0 30 60 90 120 Flow Rate (gpm) Design Head Loss (ft head) 0 1 2 3 Design PressureDrop (psi) CS150 CS200 CS250 CS100 CS Filter Head Loss Curves Specifications and Dimensions, CS Series Filters Model No.CS100 CS150 CS200 CS250CS100 CS150 CS200 CS250CS100 CS150 CS200 CS250CS100 CS150 CS200 CS250 Filter Area 100 ft2 150 ft2 200 ft2 250 ft2 Design Flow Rate 1 gpm/ft2 .85 gpm/ft2 .625 gpm/ft2 .5 gpm/ft2 Maximum Flow 100 gpm 125 gpm 125 gpm 125 gpm100 gpm 125 gpm 125 gpm 125 gpm100 gpm 125 gpm 125 gpm 125 gpm100 gpm 125 gpm 125 gpm 125 gpm Six (6) Hour Capacity 36,000 gallons 45,000 gal- lons 45,000 gallons 45,000 gal- lons Eight (8) Hour Capacity 48,000 gallons 60,000 gal- lons 60,000 gallons 60,000 gal- lons Normal Start Up Pressure 6-15 psi 6-15 psi 6-15 psi 6-15 psi6-15 psi 6-15 psi 6-15 psi 6-15 psi6-15 psi 6-15 psi 6-15 psi 6-15 psi6-15 psi 6-15 psi 6-15 psi 6-15 psi Max. Working Pressure 50 psi 50 psi 50 psi 50 psi50 psi 50 psi 50 psi 50 psi50 psi 50 psi 50 psi 50 psi50 psi 50 psi 50 psi 50 psi Cartridges Required 1 1 1 1 Shipping Weight 28 lbs. 28 lbs. 34 lbs. 36 lbs.28 lbs. 28 lbs. 34 lbs. 36 lbs.28 lbs. 28 lbs. 34 lbs. 36 lbs.28 lbs. 28 lbs. 34 lbs. 36 lbs. Height (‘A’)32" 32" 32" 42½" 42½"" 42½" 42½"" 42½" 42½" Heater without VersaFlo Heater with VersaFlo Time Water Travels Through Heater***3,000 Hours 100 Hours Time Water Bypasses Heater 0 Hours 2,900 Hours Heater without VersaFlo Heater with VersaFlo Annual Electricity Used by Pump Through Heater**3300 KW 110 KW Annual Electricity Used by Pump Bypassing Heater**0 KW 1537 KW Electricity Cost†0.21 $/KWHr 0.21 $/KWHr Total Cost to Operate Pump**$695 $345 Model #Model # with VersaFlo Firing Rate Gas Type Heat Exchanger Thermal Efficiency Dim A Weight Vent Diameter*Minimum GPM Maximum GPM JXi200N JXi200NK 200K BTU Natural Gas Copper 83%34.5 117 lbs.6" (15 cm)30 100 JXi260N JXi260NK 260K BTU Natural Gas Copper 84%34.5 120 lbs.7" (18 cm)30 100 JXi400N JXi400NK 399K BTU Natural Gas Copper 84%34.5 126 lbs.8" (20 cm)30 100 JXi400NN 399K BTU Natural Gas Cupronickel 83%34.5 126 lbs.8" (20 cm)30 100 JXi200P JXi200PK 200K BTU Propane Copper 83%34.5 117 lbs.6" (15 cm)30 100 JXi260P JXi260PK 260K BTU Propane Copper 84%34.5 120 lbs.7" (18 cm)30 100 JXi400P JXi400PK 399K BTU Propane Copper 84%34.5 126 lbs.8" (20 cm)30 100 JXi400PN 399K BTU Propane Cupronickel 83%34.5 126 lbs.8" (20 cm)30 100 JXiVFKIT JXi VersaFlo Accessory Kit (Not compatible with ASME certified heaters) ASME Certified JXi Heaters (Not available with VersaFlo Integrated Bypass technology) *Minimum vent pipe size for Category I installations. **Savings based on testing a 28,000 gallon pool with 2 turnovers per day at an average power of 0.21 $/kWHr; using a Jandy ePump, Jandy CV Filter and JXi Heater without VersaFlo, compared to the same system setup with a JXi Heater with VersaFlo. Tested in accordance with the applicable requirements of Department of Energy 10 CFR 429 and 431. ***Pool pump and filter run time based on calculated average of nationwide survey of pool owners. †Uses the average cost of electricity for residential service for Los Angeles Metro Area between August 2015 and August 2016, Source: www.bls.gov Available in the Following Models Jandy.com | 1.800.822.7933 ©2020 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks are the property of their respective owners. 5872_SL Save even more with VersaFlo™ Integrated Bypass Here’s How: • The heater is typically only used 3.5% of average annual pump runtime, the other 96.5% of the time the heat exchanger can be bypassed. • JXi™ with VersaFlo activates the built-in flow bypass valve based on call for heat to avoid running water through the heat exchanger when water does not need to be heated. • Variable-speed pumps can be run at lower speeds, requiring considerably less electricity, thereby providing for significantly reduced electricity costs. • VersaFlo Integrated Bypass is available on select models or can easily be added to any JXi heater in the field. 5-Year Heat Exchanger Warranty JXi heaters with VersaFlo factory installed receive an industry leading 5-Year standard warranty on the heat exchanger. Stop wasting electricity and money pushing water through your pool heater when you don’t need to! Cost / Energy Savings: Annual energy savings of up to $350** with VersaFlo Bypass Mode Heat Mode   Jandy JXi Gas Heater Head Loss Chart      4' 6"P/E LOCATION 80' TO MAIN DRAIN 6'10' 6"93' 6 " 35' Existing: Total Lot: 10880SF House: 3260 SF Lanai: 288 SF Front Porch: 40 SF Driveway/Walk: 636 SF A/C Pad: 10 SF Total: 4234 SF ISR:38.9% Proposed: Total Lot: 10880 SF House: 3260 SF Lanai: 288 SF Front Porch: 40 SF Driveway/Walk: 636 SF A/C Pad: 10 SF P/E Pad: 18 SF 50% Pool/Coping: 203 SF Pool Deck: 617SF Total: 5072 SF ISR:46.6% COPING: 10.0 Customer Info Revision Gen. Plan Hydraulics BENCHMARK TOP OF POOL BEAM-19 1/4" SCALE:1/8"=1' TOP OF TILE-18 3/4" Date: TOP OF COPING-17" Date: Client Name:Bannwart Residence Date: Date: Date: Notes:- Maintain min. 1" step down from all doors & stucco/ siding band - Homeowner to provide power to pool equipment RE: Notes RE: 5' - 8" DEEP SUNSHELF - UMBRELLA SLEEVE RE: STANDARD BUBBLER RE: RE: Project Manager: Company Info FTN LINE N Address:600 St. Johns Bluff Rd. N. City:Jacksonville State/Zip:Fl / 32225 Phone #:904.223.4050 Fax #:904.223.0735 E-mail:Info@pbjc.com License #:CPC 009595 & 1457425 & 1459376 & CBC 1263546 7' 1" 6' 6" (3) W/Rs 3'-6" DEEP 5'-0" DEEP Deck Area:617 ft² Lanai Area:288 ft² Pool Perimeter:79' 4" Gallons:9,683 gallons Pool Area:405 ft² SAFETY 2:PGRM-2 Pool Guard Alarm ACCESS Address:1889 Atlantic Beach Dr MIN. 1" STEP DOWN FROM ALL DOORS & STUCCO /SIDING BAND Job #:3315 Zip:32233 Designer Name:Kyle / KP Builder:Residential Neighborhood:Atlantic Beach Specs Safety Spa Area:38 ft² 6-HR Turnover Rate:36 GPMs Feature Flow Rate:20 GPMs Dist to P/E:80' Footer:n/a Spa Perimeter:21' 10" SAFETY 1:Existing Fence BENCH (2) 2" F/Rs MDX W/ SDX COVERED LANAI INC. BONDING GRIDS-4 BONDING GRIDS-4 NEW ARTISTIC PAVER DECK PBJC TO REMOVE & HAUL AWAY EXISTING PAVERS AIRBLOWERPURELINK J-BOX - NEW STEPS BY PBJC - PBJC TO REMOVE & HAUL AWAY EXISTING PAVERS - NEW ARTISTIC PAVER COPING TREADS - NEW ARTISTIC PAVER RISERS ARTISTIC PAVER DECK SKIMMER #1 ARTISTIC PAVER COPING STANDARD DECK DRAIN STANDARD DECK DRAIN PROPERTY LINE 10' B.R.L. FILTER PUMP: VSSHP220DV2A FILTER: CS 250 SALT CELL: PLC 1400 HEATER: JXi400PK H/O TO PROVIDE POWER TO P/E ELEC. PANEL: 6614AP-LG PURELINK PANEL CONTROL: RS-PS4 WIFI CONTROL: iQ30A AIRBLOWER: PSB 120 AIRBLOWER TRANSFORMER: PX 100W TRANSFORMER LT J-BOX: 5 PORT J-BOX SPA LT: (1) JLU4C 6W 100' LT POOL LTS: (2) JLU4C 24W 100' LTS - (2) NICHELESS LTS - 1.5" PIPE - 1.5" SP W/ LEAK STOP - +12" RAISED SPA - (6) JETS - (2) SDXs - (1) CMP SUMP - (1) 6W NICHELESS LT PUMP #1:FILTER PUMP Branch Line:3" Trunk Line:2.5" Return Line:2.5" Skimmers:1 Jandy Pump:VSSHP220DV2A Jandy Filter:CS 250 Heater:JXi400PK Minimum TDH:~54' Maximum Flow:117 GPM's TOP OF CONCRETE 1 A-3 1 A-3 3 A-3 3 A-3 4 A-3 4 A-3 Customer Info Revision Date: Date: Client Name:Bannwart Residence Date: Date: Date: Notes:- Maintain min. 1" step down from all doors & stucco/ siding band - Homeowner to provide power to pool equipment RE: Notes RE: RE: RE: RE: Project Manager: Company Info Address:600 St. Johns Bluff Rd. N. City:Jacksonville State/Zip:Fl / 32225 Phone #:904.223.4050 Fax #:904.223.0735 E-mail:Info@pbjc.com License #:CPC 009595 & 1457425 & 1459376 & CBC 1263546 Deck Area:617 ft² Lanai Area:288 ft² Pool Perimeter:79' 4" Gallons:9,683 gallons Pool Area:405 ft² SAFETY 2:PGRM-2 Pool Guard Alarm Address:1889 Atlantic Beach Dr Job #:3315 Zip:32233 Designer Name:Kyle / KP Builder:Residential Neighborhood:Atlantic Beach Specs Safety Spa Area:38 ft² 6-HR Turnover Rate:36 GPMs Feature Flow Rate:20 GPMs Dist to P/E:80' Footer:n/a Spa Perimeter:21' 10" SAFETY 1:Existing Fence 2.5" TRUNK LINE 3" PIPE SDX MDX 10" BEAM 1 1/2" WATERLINE FOR BUBBLER 21" FROM T.O.B MIN. 10" PIPE BEFORE CONDUIT 1.5" PIPE 18" 8" 12" Scale: nts Bubbler Detail SOIL 10" BEAM 3" 6" S.Detail Page Scale: nts A-2 21" FROM T.O.B 2" F/R 2" PIPE MIN. 7" PIPE BEFORE CONDUIT SOIL 18" CONCRETE CUT PIPE HERE 1" x 1" CUTOUT AROUND THE PIPE FOR WATER STOP 2" SCH. 40 PIPE MIN. 39" 1" CONDUIT Scale: nts 1.5" PIPE 1.5" Wall Return 6" Scale: nts Scale: nts Pool Light Detail 3" Paralevel Autofill/Overflow Detail 3" 1" CONDUIT 3" 17 1/4" CUTOUT 3/4" CUTOUT TO BOTTOM OF FLANGE Scale: nts MDX Detail26" 12" 1 1/2" PVC PIPE 18" WATER SUPPLY CUT AT DESIRED OVERFLOW LEVEL Scale: nts MDX / SDX Detail Scale: nts Spa Light Detail 1.5" PIPE 1 1/2" SP W/ LEAK STOP C. Detail Page A-3 2'3'3'3' 3'3'2'4'1' 6" 6' 6" 4' Customer Info Revision Date: Date: Client Name:Bannwart Residence Date: Date: Date: Notes:- Maintain min. 1" step down from all doors & stucco/ siding band - Homeowner to provide power to pool equipment RE: Notes RE: - 8" DEEP SUNSHELF - UMBRELLA SLEEVE RE: STANDARD BUBBLER RE: RE: Project Manager: Company Info FTN LINE Address:600 St. Johns Bluff Rd. N. City:Jacksonville State/Zip:Fl / 32225 Phone #:904.223.4050 Fax #:904.223.0735 E-mail:Info@pbjc.com License #:CPC 009595 & 1457425 & 1459376 & CBC 1263546 - +12" RAISED SPA - 7'-0" INSIDE DIA. - 3'-0" TILE SPILLWAY - TILE EXTERIOR - DBL B-NOSE ARTISTIC PAVER COPING TOP - (6) JETS - (2) SDXs - (1) CMP SUMP - (1) 6W NICHELESS LT - REFERENCE STANDARD POOL/ SPA ENGINEERING (S-4) Deck Area:617 ft² Lanai Area:288 ft² Pool Perimeter:79' 4" Gallons:9,683 gallons Pool Area:405 ft² SAFETY 2:PGRM-2 Pool Guard Alarm Address:1889 Atlantic Beach Dr Job #:3315 Zip:32233 Designer Name:Kyle / KP Builder:Residential Neighborhood:Atlantic Beach Specs Safety Spa Area:38 ft² 6-HR Turnover Rate:36 GPMs Feature Flow Rate:20 GPMs Dist to P/E:80' Footer:n/a Spa Perimeter:21' 10" SAFETY 1:Existing Fence 2 A-3 SPA JET 10" BELOW T.O.B.10" 10" BEAM REFERENCE STANDARD POOL/ SPA ENGINEERING (S-4) SPA 21" FROM T.O.B 23" FROM TOP OF BENCH 18" 2" 1 A-3 Spa Plan Scale: 1/8" : 1' 1 A-3 Spa Plan Scale: 1/8" : 1' 2 A-3 Spa Detail Scale: NTS 3 A-3 Sunshelf Plan Scale: 1/8" : 1' 4 A-3 Deck Detail Scale: NTSDECK PATTERNNEED SELECTIONS Plumbing Plan Customer Info Revision Date: Date: Client Name:Bannwart Residence Date: Date: Date: Notes:- Maintain min. 1" step down from all doors & stucco/ siding band - Homeowner to provide power to pool equipment RE: Notes RE: RE: RE: RE: Project Manager: Company Info Address:600 St. Johns Bluff Rd. N. City:Jacksonville State/Zip:Fl / 32225 Phone #:904.223.4050 Fax #:904.223.0735 E-mail:Info@pbjc.com License #:CPC 009595 & 1457425 & 1459376 & CBC 1263546 Deck Area:617 ft² Lanai Area:288 ft² Pool Perimeter:79' 4" Gallons:9,683 gallons Pool Area:405 ft² SAFETY 2:PGRM-2 Pool Guard Alarm Address:1889 Atlantic Beach Dr Job #:3315 Zip:32233 Designer Name:Kyle / KP Builder:Residential Neighborhood:Atlantic Beach Specs Safety Spa Area:38 ft² 6-HR Turnover Rate:36 GPMs Feature Flow Rate:20 GPMs Dist to P/E:80' Footer:n/a Spa Perimeter:21' 10" SAFETY 1:Existing Fence Customer Info Revision -19 1/4" Layout Plan -18 3/4" Hydraulics -17" BENCHMARK TOP OF POOL BEAM SCALE:1/8"=1' TOP OF TILE Date: TOP OF COPING Date: Client Name:Bannwart Residence Date: Date: Date: Notes:- Maintain min. 1" step down from all doors & stucco/ siding band - Homeowner to provide power to pool equipment RE: Notes RE: 6'2'RE: RE: RE: Project Manager: Company Info N Address:600 St. Johns Bluff Rd. N. City:Jacksonville State/Zip:Fl / 32225 Phone #:904.223.4050 Fax #:904.223.0735 E-mail:Info@pbjc.com License #:CPC 009595 & 1457425 & 1459376 & CBC 126354610'Deck Area:617 ft² Lanai Area:288 ft² Pool Perimeter:79' 4" Gallons:9,683 gallons Pool Area:405 ft² SAFETY 2:PGRM-2 Pool Guard Alarm ACCESS Address:1889 Atlantic Beach Dr MIN. 1" STEP DOWN FROM ALL DOORS & STUCCO /SIDING BAND 3'-0" x 3'-0" PADS Job #:3315 Zip:32233 Designer Name:Kyle / KP Builder:Residential Neighborhood:Atlantic Beach Specs Safety Spa Area:38 ft² 6-HR Turnover Rate:36 GPMs Feature Flow Rate:20 GPMs Dist to P/E:80' Footer:n/a Spa Perimeter:21' 10" SAFETY 1:Existing Fence OVERALL DIM: 16'-3" x 35'-0" SPA DIA: 7'-0" COVERED LANAI INC. PUMP #1:FILTER PUMP Branch Line:3" Trunk Line:2.5" Return Line:2.5" Skimmers:1 Jandy Pump:VSSHP220DV2A Jandy Filter:CS 250 Heater:JXi400PK Minimum TDH:~54' Maximum Flow:117 GPM's TOP OF CONCRETE 7' 8"AIRBLOWERPURELINK 21 ' 3 " J-BOX 15 ' 4 " 31' 3" 19' 10" 12' 8" 32' 4"11' 4"1' 8"R:8'-0" R:12'-0" R:20'-0" R:6'-0" R:25'-2" R:4'-6"17' 2" 14' 8" 14' 2 0 ' 5 " 6' 6" 7' 1" Simplified  Total  Dynamic  Head  (TDH)  Calculation  Worksheet   Determine  Maximum  System  Flow  Rate   Minimum  Flow  Rate  Required:  35gpm  per  skimmer  (required:  1  skimmer  per  800  sq  ft  of  surf.  area)   1.Calculate  Pool  Volume  _____________X  ___________  X    7.48    (gal./cubic  foot)  =  ____________________ (Surface  Area)  (Avg  Depth)              (Volume  in  Gallons)   2.Determine  preferred  Turnover  Time  in  Hours:  __________  X  60  (min  /  hour)  =_________________ (Hours)                        (Turnover  in  min)   3.Determine  Max  Flow  Rate  ________________  /  ________________  +  ______________  =  ___________________ (Volume  in  Gallons)                        (Turnover  in  Min)                    (Pool  Flow  Rate)        (System  Flow  Rate)   4.Spa  Jets:  __________  X  ____________  GPM  per  jet  =  ____________________  flow  rate (No  of  Jets)  (Jet  Flow)  (Total  Jet  Flow  Rate)   (For Single Pump pool/spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool & Spa) Determine  Pipe  Sizes:   Suction Branch to be _______ inch to keep velocity @ 6 fps max. at _____ gpm Maximum System Flow Rate Suction Piping to be _______ inch to keep velocity @ 8 fps max. at _____ gpm Maximum System Flow Rate Return Piping to be _______ inch to keep velocity @ 8 fps max. at _____ gpm Maximum System Flow Rate Determine Simplified TDH: 1.Distance from pool, to pump in Ft:___________ 2.Friction loss (in suction pipe) in _______ inch pipe per 1 t. @ gpm = _____(from pipe flow/friction loss chart) 3.Friction loss (in return pipe) in ________ inch pipe per 1 t. @ gpm = _____(from pipe flow/friction loss chart) 4.________________ X ___________________ = ______________ (Length of Suction Pipe) (Ft of head/1 ft of Pipe) (TDH Suction Pipe) 5.________________ X ___________________ = ______________ (Ft of head/1 ft of Pipe)(Length of Return Pipe) (TDH Suction Pipe) Flow and Friction Loss Per Foot (Schedule 40 pvc Pipe) Velocity  -­‐  Feet  Per  Second   Pipe  Size  6  FPS  8  FPS   1.5"  37  gpm  0.08'  50  gpm  .14'   2"  62gpm  0.06'  82  gpm  .10"   2.5"  88  gpm  0.05'  117  gpm  .08'   3"  136  gpm  0.04'  181  gpm  .07'   Selected  Pump  and  Main  Drain  Cover:   Pump  selection  ___________________________________            using  pump  curve  for  TDH  &  System  Flow  Rate   (Pump  model  and  size  in  HP)   Main  Drain  Cover_________________________________          (System  Flow  Rate  must  not  exceed  approved  cover  flow  rates)   (model  )   Notes:  Minimum  system  flow  based  on  minimum  flow  per  skimmer  of  35  gpm.   Determine  the  Number  and  Type  of  Required  In-­‐floor  Suction  Outlets:   (Check  all  that  apply)   ☐¤←3’ → ¤ ____________ suction outlets @ ____________gpm max. flow (see note 2) ☐¤ ¤ ¤ _____________ suction outlets @ ____________gpm max. flow (see note 3) ☐_____________ channel drain @ ____________gpm w/ _______ports (see note 4) ANSI/APSP 5&7,  2013  Specifies  three  methods  for  determining  the  maximum  system  flow  rate.     The  following  simplified  TDH  calculation  is  one  of  the  methods  specified.                            TDH  in  Piping______________              Filter  loss  in  TDH  (from  filter  data  sheet)______________   Heater  loss  in  TDH  (from  heater  data  sheet)______________                          Total  all  other  loss______________        Total  Dynamic  Head  (TDH)______________   Velocity  -­‐  Feet  Per  Second   Pipe  Size  6  FPS  8  FPS   1.5"  37  gpm  0.08'  50  gpm  .14'   2"  62  gpm  0.06'  82    gpm  .10"   2.5"  88  gpm  0.05'  117  gpm  .08'   3"  136  gpm  0.04'  181  gpm  .07'   4"  234  gpm  0.03'  313  gpm  .05'   6"  534  gpm  0.02'  712  gpm  .03'   TDH  Calculation  Options   (For  each  Pump)   Check  one   ☐Simplified  Total  Dynamic  Head  (STDH) Complete  STDH  Worksheet  –  Fill  in  all  blanks ☐Total  Dynamic  Head  (TDH) Complete  Program  or  other  calcs.  Fill  in required  blanks  on  worksheet  &  attach calculations ☐Maximum  Flow  Capacity of  the  new  or  replacement  pump Notes:   1.If  a  variable  speed  pump  is  used,  use  the  max pump  low  in  calculations 2.For  side  wall  drains,  use  appropriate  side  wall drain  flow  as  published  by  manufacturer 3.Insert  manufacturer’s  name  and  approved maximum  flow 4.See  installation  instructions  for  number  of ports  to  be  used 5.In-­‐Floor  suction  outlet  cover/grate  must conform  to  most  recent  edition  of  ASME/ANSI A112.19.8  and  be  embossed  with  that  edition approval 6.Pump,  Filter  and  Heater  make  and  model cannot  change,  and  equipment  location  cannot be  move  closer  the  pool  without  submitting  a revised  plan  and  TDH  calculation  worksheet  for approval Flow and Friction Loss Per Foot (Schedule 40 pvc Pipe) ANSI/APSP/ICC  Worksheet   Swimming Pool Energy Efficiency Compliance Information Note: These Requirements Apply ONLY to the Filtration Pump Maximum Filtration Flow Rate Calcutlations Pool Water Voume______÷ 360 =______ gpm = filtration flow rate Is there an Auxiliary load on the filtration pump? Yes___ NO____ If so, what is the auxiliary flow rate _______gpm Maximum Flow Rate ______gpm (maximum auxiliary pool loads or the filtration flow rate, whichever is greater. The pool filtration flow rate shall not be greater than the rate needed to turn over the pool water volume in 6 hours or 36 gpm whichever is greater. This means that for pools of less than 13000 gallons, the pump shall be sized to have a flow rate of 36 gpm or less. Suction Pipe size @ 8 fps ________inch Return Pipe size @ 8 fps ________inch Filter Factors: (Cartridge .375) or (D.E 2) or (Sand 15) ____________÷ _____________=___________________ (flow rate) (filter factor) (minimum filter size) Filter Make/Size __________________________________ Backwash valve? Yes_____ No______ (if yes, must be 2 inch min) Pump Selection from APSP database on Curve A (less than 17000 gallons) or C (greater than 17000 gallons) (circle one) Model_________________________________________ Flow Rate (low speed)______gpm @ ______rpm Flow Rate (high speed) ______gpm @ ____ rpm Date   _____________________________________________________   Contractors  Signature   _____________________________________________________   Print  Name   _____________________________________________________   Certification  Number   _____________________________________________________   Telephone  Number   Pump Controls Standard time clock / 2 speed time clock _____or other ______ Heater Model _______________________________________ Notes: suction piping in front of pump inlet must be 4 pipe diameters in length. Must have 18” of straight pipe after the filter for solar. Swimming  Pool  Specifications  for:   Owner:____________________________________________________________   Address___________________________________________________________   City,  State,  Zip____________________________________________________   ____________________________________________________________________   _____________________________________________________________________   _____________________________________________________________________   _____________________________________________________________________   _____________________________________________________________________ _____________________________________________________________________