Loading...
1894 Atlantic Beach ERES24-0185 permitOWNER:ADDRESS:CITY:STATE:ZIP: CLARKSON JOHN 1894 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: NATIONWIDE ELECTRIC 5627 -1 VE VERNA BLVD JACKSONVILLE FL 32205 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1585 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1894 ATLANTIC BEACH ELECTRICAL RESIDENTIAL ELECTRICAL FOR 24 kw GENERATOR WITH ATS $12037.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $94.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/16/2024 PERMIT NUMBER ERES24-0185 ISSUED: 8/16/2024 EXPIRES: 2/12/2025 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 8/16/2024 PERMIT NUMBER ERES24-0185 ISSUED: 8/16/2024 EXPIRES: 2/12/2025 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $94.00 ERES24-0185 Address: 1894 ATLANTIC BEACH APN: 169505 1585 $94.00 ELECTRICAL $90.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R27987 $94.00 Printed: Friday, August 16, 2024 10:48 AM Date Paid: Friday, August 16, 2024 Paid By: NATIONWIDE ELECTRIC Pay Method: CREDIT CARD 10078764774 1 of 1 Cashier: KW Cash Register Receipt City of Atlantic Beach Receipt Number R27987 NATIONWIDE ELECTRIC INC. 1633 Farm Way Suite 501 Middleburg, FL, 32068 +1 (904) 695-1588 Sizing Report Sizing Information for: JOHN Clarkson 1894 Atlantic Beach Dr Atlantic Beach, FL, 32233 Rated Nominal Voltage 120 / 240 Single Phase Generator Fuel Choice Natural Gas Sizing Method (NEC 220)Part IV General Lighting & Receptacles Load (kW) Square Footage Being Covered (ft^2)3000 9.00 Small Appliance Circuits (20 amps) Kitchen Circuits 2.00 3.00 Laundry Circuits 1.00 1.50 Fixed-In-Place Appliances & Motors ManagedLoads Estimated(kW)Nameplate(amps)240 V Load (kW) Dishwasher 1.50 12.50 1.50 Garage Door Opener 0.60 5.00 0.60 Microwave 1.25 10.42 1.25 Oven 5.00 20.83 X 5.00 Refrigerator 0.80 6.67 0.80 Air Conditioning & Cooling ManagedLoads Estimated(kW)Nameplate(amps)240 V Load (kW) Heating & Heat Pumps ManagedLoads Estimated(kW)Nameplate(amps)240 V Load (kW) Heat Pump (4 Ton)4.00 16.67 X 4.00 Transient Requirement Estimated(LRA)Actual(LRA)Utilized(LRA) Largest Motor's Starting Amps (LRA)115.0 0.00 115.0 Summary NEC Load Load(kW)NECRequired General Lighting & Receptacles 13.50 Fixed-in-Place Appliances & Motors 9.15 Sum of all General Loads 22.65 15.060 Cooling 0 0 Heating (w/demand factors)4.00 4.0000 Larger of Heating & Cooling 4.00 4.0000 Sizing based on requirements of NEC Article 220: Part IV 19.0600 Elevation 0 Minimum size generator for motor starting requirements 18 BTU load required 306000 24 kW Generac Model Generator Recommended JOHN Clarkson (1) | Page 6 1 of 6 ® INCLUDES: True Power™ Electrical Technology Two-line multilingual digital LCD Evolution™ controller (English/Spanish/French/Portuguese) 200 amp service rated transfer switch available Electronic governor Standard Wi-Fi® connectivity System status & maintenance interval LED indicators Sound attenuated enclosure Flexible fuel line connector Natural gas or LP gas operation 5 Year limited warranty Listed and labeled for installation as close as 18 in (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. 20/22/24 kW Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 HzG007042-10, G007042-11, G007043-10, G007043-11(Aluminum - Bisque) - 22 kW 60 HzG007209-10, G007210-10 (Aluminum - Bisque) - 24 kW 60 Hz 20/22/24 kWNote: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. or GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac’s success in providing the most reliable generators possible. Generac’s G- Force engine lineup offers added peace of mind and reliability for when it’s needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems. SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. TEST CRITERIA: PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. TM Product shown with optional fascia kit JOHN Clarkson (1) | Page 8 2 of 6 ® Engine Generac G-Force design Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. “Spiny-lok” cast iron cylinder walls Rigid construction and added durability provide long engine life. Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. High temperature shutdown Prevents damage due to overheating. Generator Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. Displaced phase excitation Maximizes motor starting capability. Automatic voltage regulation Regulating output voltage to ±1% prevents damaging voltage spikes. EPA Certified for non-emergency applications Allows unit to be used for demand response applications (excluding 20 kW units). UL 2200 listed For your safety. Transfer Switch (if applicable) Fully automatic Transfers vital electrical loads to the energized source of power. NEMA 3R Can be installed inside or outside for maximum flexibility. Integrated load management technology Capability to manage additional loads for efficient power management. Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution™ Controls AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy, at-a-glance status indication in any condition. Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Sealed, raised buttons Smooth, weather-resistant user interface for programming and operations. Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Engine warm-up Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Engine cool-down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. Main line circuit breaker Protects generator from overload. Electronic governor Maintains constant 60 Hz frequency. Unit SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.20/22/24 kW20/22/24 kW Features and Benefits JOHN Clarkson (1) | Page 9 3 of 6 ® Installation System 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity (Wi-Fi equipped models only) Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. Monthly report with previous month’s activity Detailed monthly reports provide historical generator information. Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. Weather information Provides detailed local ambient weather conditions for generator location.20/22/24 kW20/22/24 kW Features and Benefits JOHN Clarkson (1) | Page 10 4 of 6 ® Generator Model G007038-1G007039-1 (20 kW) G007042-10G007043-10(22 kW) G007038-3G007039-3 (20 kW) G007042-11G007043-11 (22 kW) G007209-10G007210-10(24 kW) Rated maximum continuous power capacity (LP)20,000 Watts*22,000 Watts* 20,000 Watts* 22,000 Watts* 24,000 Watts* Rated maximum continuous power capacity (NG) 18,000 Watts* 19,500 Watts*18,000 Watts* 19,500 Watts*21,000 Watts* Rated voltage 240 Rated maximum continuous load current – 240 volts (LP/NG)83.3 / 75.0 91.7 / 81.3 83.3 / 75.0 91.7 / 81.3 100 / 87.5 Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement (not included) 12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight (lb / kg)448 / 203 466 / 211 436 / 198 445 / 202 455 / 206 Dimensions (L x W x H) in / cm 48 x 25 x 29 / 121.9 x 63.5 x 73.7 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load**67 67 67 67 67 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode**55 57 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/ cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/ magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx. 1.9 qt / 1.8 L Operating rpm 3,600 Fuel consumptionNatural gas ft³/hr (m³/hr) 1/2 Load Full LoadLiquid propane ft3/hr (gal/hr) [L/hr] 1/2 Load Full Load 204 (5.78) 301 (8.52) 87 (2.37) [8.99] 130 (3.56) [13.48] 228 (6.46) 327 (9.26) 92 (2.53) [9.57] 142 (3.90) [14.77] 164 (4.64) 287 (8.13) 86 (2.36) [8.95] 136 (3.74) [14.15] 203 (5.75) 306 (8.66) 92 (2.53) [9.57] 142 (3.90) [14.77] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5–7 in water column (0.87–1.74 kPa) for NG, 10–12 in water column (2.49–2.99 kPa) for LPgas. For BTU content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OFF Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2–1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable (brownout setting)From 140-171 V / 190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard Rating definitions - Optional Standby: Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating.(All ratings in accordance with BS5514, ISO3046, UL2200, and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreasesapproximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C).**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.20/22/24 kW20/22/24 kW Specifications JOHN Clarkson (1) | Page 11 5 of 6 ®20/22/24 kWDimensions Service Rated Automatic Transfer Switch Features Intelligently manages up to four air conditioner loads with no additional hardware. Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). Electrically operated, mechanically-held contacts for fast, clean connections. Main breakers are rated for 80% continuous load. 2-pole, 250 VAC contactors. Service equipment rated, dual coil design. Rated for both aluminum and copper conductors. Main contacts are silver plated or silver alloy to resist welding and sticking. NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. 200 Amps 120/240, 1ø Open Transition Service Rated Height Width DepthH1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 *Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly Model G007039-1, G007039-3 (20 kW) G007043-10, G007043-11 (22 kW) G007210-10 (24 kW) No. of poles 2 Current rating (amps)200 Voltage rating (VAC)120/240, 1Ø Utility voltage monitor (fixed)* -Pick-up -Dropout 80% 65% Return to Utility*Approx. 13 sec ETL or UL listed Standard Enclosure type NEMA/UL 3R Circuit breaker protected 22,000 Lug range 250 MCM - #6 H2 DEPTH H1 W2 W1 20/22/24 kW Switch Options JOHN Clarkson (1) | Page 12 6 of 6 ® Model #Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 °F (-18 °C). (Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if temperature regularly falls below 0 °F (-18 °C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch Contact Kit The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be needed. Not compatible with 50 amp pre-wired switches. G007027-0 - Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). G007005-0 Wi-Fi LP Tank Fuel Level Monitor The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amp) G007006-0 (100 amp) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large elec- trical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM’s can reduce the overall size and cost of the system. G007169-0 - 4G LTE G007170-0 - Wi-Fi/ Ethernet Mobile Link® Cellular Accessories The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Us- ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. G007220-0 - Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators. This offers a sleek, contoured appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit contains four plugs, sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 648 mm[25.5 in] 727.2 mm[28.6 in] 637.6 mm[25.1 in] 1232 mm[48.5 in] 1218 mm[48.0 in] LEFT SIDE VIEW FRONT VIEW Model UPC G007038 696471074185 G007039 696471074192 G007042 696471074208 G007043 696471074215 G007209 696471071511 G007210 69647108480120/22/24 kWGenerac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2022 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. A0000937814 Rev. E 03/15/2022 ® 20/22/24 kW Available Accessories JOHN Clarkson (1) | Page 13 1 of 1 Model 005819-0 GENERAC® ACCESSORIES 26R Battery® 26R Battery ®Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2013 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0183690SBY-G Printed in U.S.A. 07/09/13 DESCRIPTION Every standby generator requires a battery to start the system. In efforts to achieve the easiest generator installation, Generac offers the recommended 26R, wet cell battery applicable for all air-cooled standby generators. SPECIFICATIONS Dimensions (L x W x H) Battery .................................................................................................................................................................................................................................................8.7" x 6.8" x 7.6" Shipping Dimensions ..............................................................................................................................................................................................................................9" x 7.3" x 8.7" Weight ..........................................................................................................................................................................................................................................................30 pounds Cold Cranking Amps ...............................................................................................................................................................................................................................................525 Warranty .......................................................................................................................................................................................................................................1 year from shipment Brand ....................................................................................................................................................................................................................................................................Exide JOHN Clarkson (1) | Page 14