Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
712 AMBERJACK LN MCRS24-0014 FULL 410s IQ8MC PLUS NXT 1
Q.PEAK DUO BLK ML-G10+ Q.PEAK DUO BLKML-G10+ SERIES MODEL 385 - 410 Wp | 132 Cells 20.9 % Maximum Module Efficiency PV MODULERELIABILITY SCORECARD 2022TOP PERFORMER TOP BRAND PV MODULES USA2022 1 See data sheet on rear for further information.² APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) The ideal solution for: Rooftop arrays on residential buildings Qcells is the first solar module manufacturer to pass the most comprehensive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. The most thorough testing programme in the industry Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. Breaking the 20 % efficiency barrier Innovative all-weather technology Optimal yields, whatever the weather with excellent low-light and temperature behaviour.6 busbarcell technology 12 busbarcell technology High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). Extreme weather rating Inclusive 25-year product warranty and 25-year linear performance warranty1. A reliable investment Long-term yield security with Anti LeTID Technology, Anti PID Technology2 and Hot-Spot Protect. Enduring high performance NA DETAIL A 0.63" (16 mm) 0.33" (8.5 mm)0.96" (24.5 mm) 42.8" (1088 mm) 74.0" (1879 mm) 4 × Mounting slots (DETAIL A) Frame 41.1" (1045 mm) 39.2" (996 mm) 1.26" (32 mm) 8 × Drainage holes 15.6" (395.5 mm) 4 × Grounding points ø 0.18" (4.5 mm) Label ≥49.2" (1250 mm) ≥49.2" (1250 mm) Format 74.0 in × 41.1 in × 1.26 in (including frame)(1879 mm × 1045 mm × 32 mm) Weight 48.5 lbs (22.0 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in(53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 49.2 in (1250 mm), (−) ≥ 49.2 in (1250 mm) Connector Stäubli MC4; IP68 Mechanical Specification Qcells pursues minimizing paper output in consideration of the global environment. Note: Installation instructions must be followed. Contact our technical service for further information on approved installation of this product.Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL hqc-inquiry@qcells.com | WEB www.qcells.com Q.PEAK DUO BLK ML-G10+ SERIES Specifications subject to technical changes © Qcells Q.PEAK_DUO_BLK_ML-G10+_series_385-410_2023-01_Rev03_NAProperties for System Design Maximum System Voltage VSYS [V]1000 (IEC) / 1000 (UL)PV module classification Class II Maximum Series Fuse Rating [A DC]20 Fire Rating based on ANSI / UL 61730 TYPE 2 Max. Design Load, Push / Pull3 [lbs / ft2]75 (3600 Pa) / 55 (2660 Pa)Permitted Module Temperature on Continuous Duty −40 °F up to +185 °F(−40 °C up to +85 °C)Max. Test Load, Push / Pull3 [lbs / ft2]113 (5400 Pa) / 84 (4000 Pa) 3 See Installation Manual UL 61730, CE-compliant,Quality Controlled PV - TÜV Rheinland, IEC 61215:2016, IEC 61730:2016, U.S. Patent No. 9,893,215 (solar cells), Qualifications and Certificates 200 400 600 800 1000 90 100 80 110 10 251520005 86 98 95 80 100 85 Electrical Characteristics TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC α [% / K]+0.04 Temperature Coefficient of VOC β [% / K]−0.27 Temperature Coefficient of PMPP γ [% / K]−0.34 Nominal Module Operating Temperature NMOT [°F]109 ± 5.4 (43 ± 3 °C) POWER CLASS 385 390 395 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP [W]385 390 395 400 405 410 Short Circuit Current1 ISC [A]11.04 11.07 11.10 11.14 11.17 11.20 Open Circuit Voltage1 VOC [V]45.19 45.23 45.27 45.30 45.34 45.37 Current at MPP IMPP [A]10.59 10.65 10.71 10.77 10.83 10.89 Voltage at MPP VMPP [V]36.36 36.62 36.88 37.13 37.39 37.64 Efficiency1 η [%]≥ 19.6 ≥ 19.9 ≥ 20.1 ≥ 20.4 ≥ 20.6 ≥ 20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP [W]288.8 292.6 296.3 300.1 303.8 307.6 Short Circuit Current ISC [A]8.90 8.92 8.95 8.97 9.00 9.03 Open Circuit Voltage VOC [V]42.62 42.65 42.69 42.72 42.76 42.79 Current at MPP IMPP [A]8.35 8.41 8.46 8.51 8.57 8.62 Voltage at MPP VMPP [V]34.59 34.81 35.03 35.25 35.46 35.68 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • ²800 W/m2, NMOT, spectrum AM 1.5 RELATIVE EFFCIENCY [%]Qcells PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Qcells sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2). YEARS IRRADIANCE [W/m²] Qcells Industry standard of p-mono* *Standard terms of guarantee for the 5 PV companies with the highest production capacity in 2021 (February 2021) CertifiedUL 61730RELATIVE EFFCIENCYCOMPARED TO NOMINAL POWER [%] IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 DATA SHEET IQ8MC Microinverter Our newest IQ8 Series Microinverters are the industry’s first microgrid-forming*, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conforms with various regulations when installed according to the manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters that have integrated MC4 connectors. Easy to install • Lightweight and compact with plug-and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produces power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative. An IQ Gateway is required to make these changes during installation. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC Microinverter INPUT DATA (DC)UNITS IQ8MC-72-M-US Commonly used module pairings 1 W 260–460 Module compatibility —To meet compatibility, PV modules must be within the following max. input DC voltage and max. module Isc. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25–45 Operating range V 18–58 Min./Max. start voltage V 22/58 Max. input DC voltage V 60 Max. continuous operating DC current A 14 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires max 20 A per branch circuit OUTPUT DATA (AC) UNITS IQ8MC-72-M-US @240 VAC IQ8MC-72-M-US @208 VAC Peak output power VA 330 315 Max. continuous output power VA 320 310 Nominal grid voltage (L-L) V 240, split-phase (L-L), 180°208, single-phase (L-L), 120° Min./Max. grid voltage 2 V 211–264 183–229 Max. continuous output current A 1.33 1.49 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short circuit fault current over three cycles Arms 2.70 Max. units per 20 A (L-L) branch circuit 3 —12 10 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 18 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading ... 0.85 lagging Peak efficiency %97.4 97.2 CEC weighted efficiency %97.0 96.5 Nighttime power consumption mW 33 25 MECHANICAL DATA UNITS Ambient temperature range -40°C to 65°C (-40°F to 149°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D); Weight 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2"); 1.1 kg (2.43 lbs) Cooling Natural convection – no fans Approved for wet locations; Pollution degree Yes; PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environ. category; UV exposure rating NEMA Type 6; outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer’s instructions. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 Revision history REVISION DATE DESCRIPTION DSH-00049-4.0 February 2024 Added information about IEEE 1547 interconnection standard requirements. DSH-00049-3.0 October 2023 Included NEC 2023 specification in the “Compliance” section. DSH-00049-2.0 September 2023 Updated module compatibility information. DSH-00049-1.0 May 2023 Preliminary release. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PART & ASSEMBLY 9/30/2021 MODULE ASSEMBLY REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A01PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET RAIL SEE PAGE NH-P01 RAIL SPLICE SEE PAGE NH-P02 STRONGHOLD ATTACHMENT KIT SEE PAGE NH-A04 COMBO CLAMP SEE PAGE NH-A03 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PART & ASSEMBLY 9/30/2021 MODULE ASSEMBLY REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A02PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET MLPE & LUG CLAMP SEE PAGE NH-A06 WIRE MGMT CLIP SEE PAGE NH-A08 NS WIRE MGMT CLIP SEE PAGE NH-A07 RAIL & CLAMP CAP KIT SEE PAGE NH-A09 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PART & ASSEMBLY 9/30/2021 COMBO CLAMP REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A03PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET 112" 114" PART # TABLE P/N DESCRIPTION CCLAMPM1 NXT HORIZON COMBO CLAMP - MILL CCLAMPD1 NXT HORIZON COMBO CLAMP - DARK 38" 30MM TO 40MM MODULE FRAME 1 2" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PARTS ASSEMBLY 9/22/2021 STRONGHOLD ATTACHMENT REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A04PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION SHCPKTM1 STRONGHOLD ATT KIT COMP MILL SHCPKTD1 STRONGHOLD ATT KIT COMP DRK SHCPKTM1-NS STRONGHOLD ATT COMP MILL (NS) SHCPKTD1-NS STRONGHOLD ATT COMP DRK (NS) 5/16"-18 x 2" SERRATED FLANGE HEX SCREW 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER 31 2" 4916" 21316"4 316 to 3 716 HEIGHT ADJUSTMENT 5 16" 33 8" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PARTS ASSEMBLY 9/22/2021 STRONGHOLD RAIL CLAMP REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A05PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION SHCLMPM1 STRONGHOLD RAIL CLAMP MILL SHCLMPD1 STRONGHOLD RAIL CLAMP DRK 5/16"-18 x 2" SERRATED FLANGE HEX SCREW 114" 134" 2916" 2" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PARTS ASSEMBLY 9/22/2021 MLPE & LUG CLAMP REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A06PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION LUGMLPE1 NXT HORIZON MLPE & LUG CLAMP 5/16"-18 x 1" SERRATED FLANGE HEX SCREW 1516" 118" 2" R116" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PARTS ASSEMBLY 9/22/2021 NS WIRE MGMT CLIP REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A07PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION WRMCNSD1 NXT HORIZON NS WIRE MGMT CLIP 5/16"-18 x 1" SERRATED FLANGE HEX SCREW 1516" 2316" 11 2" 3 8"R18" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PARTS 10/27/2021 WIRE MGMT CLIP REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A08PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION WRMCLPD1 NXT HORIZON WIRE MGMT CLIP 1316" 58" R112" 1 8" 12" 1116" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PARTS 9/15/2021 RAIL & CLAMP CAP REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-A09PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION ENDCAPD1 NXT HORIZON RL & CLMP CAP KIT 11516" 1516"11516" 916" 116" 11316" 178" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PART DETAIL 9/13/2021 RAIL REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-P01PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION LENGTH 084RLM1 NXT HORIZON RAIL 84" MILL 84" 084RLD1 NXT HORIZON RAIL 84" DARK 84" 168RLM1 NXT HORIZON RAIL 168" MILL 168" 168RLD1 NXT HORIZON RAIL 168" DARK 168" 208RLM1 NXT HORIZON RAIL 208" MILL 208" 208RLD1 NXT HORIZON RAIL 208" DARK 208" 246RLM1 NXT HORIZON RAIL 246" MILL 246" 246RLD1 NXT HORIZON RAIL 246" DARK 246" 11116" LENGTH134" 13 8" 1716" 78" LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS NXT HORIZON PART DETAIL 9/22/2021 RAIL SPLICE REVISION DATE: DRAWING TYPE: DESCRIPTION:NH-P02PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART # TABLE P/N DESCRIPTION LENGTH RLSPLCM1 NXT HORIZON RAIL SPLICE 10" 112" 10" 1716" 4X - 5/16"-18 x 5/8" HEX FLANGE SCREW - TYPE F 1116" 114" X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C To learn more about Enphase offerings, visit enphase.com Data SheetEnphase Networking Smart • Includes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Supports Wi-Fi, Ethernet, or cellular connectivity • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ-C-4-4C-DS-0103-EN-US-12-29-2022 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage)64A Max. fuse/circuit rating (output)90A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD)37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors• 60A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Altitude Up to 3,000 meters (9,842 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet Optional, IEEE 802.3, Cat5E (or Cat6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA)IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C IQ-C-4-4C-DS-0103-EN-US-12-29-2022