712 AMBERJACK MCRS24-0014 ENGINEERING LETTERMichael S. Rezk Engineer-PE Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd South Plainfield, NJ 07080 Re: Proposed Photovoltaic Solar Panel Installation Dear Plan Reviewer: Roof Type: Attachment System:Wind Zone 1 Wind Zone 2 Wind Zone 3 3. Solar Modules shall be UL-1703 rated. Refer to manufacturers specifications sheets. 4. Positive drainage of the system shall be so as not to void the existing roof warranty. 6. Please refer to the attached structural calculations. Michael S. Rezk, P.E. FL. Lic. No. PE95844 Regarding the solar panel array installation on the above referenced project please note that an inspection was performed by a representative of the Architect/Engineer of Record, and analysis of the existing structure was conducted. There is adequate structural capacity for the installation of the array with the following recommendations: ATLANTIC BEACH, FL 32233 1. The array will be installed on the existing roof. The roof framing is constructed of 2"x4" wood trusses @24" o.c. spanning 12' 5" with a top chord length of 12' 7" with intermediate supports at 1/2 points, making the effective longest span equals 8' with 1/2" plywood sheathing. The new array (See Site map by contractor) will add 2.63 Lb. / Sf. overall to the roof. The existing structure is sufficient to support the new loads associated with the additional weight & wind resistance. No additional structural support is required for the roof structure. 5. All aspects of the installation shall comply with the Florida Administrative Code, 2023 Florida Building Code - Residential 8th Edition, ASCE-7-22, 2023 Florida Building Code – Energy Conservation, 8th Edition, 2020 National Electric Code, All Local Governing County and Municipal Ordinances adopted by reference or enacted by law. All components used meet the criteria of the Florida Solar Energy Center. If you have any questions relating to this matter, please contact me at your earliest convenience. Thank you. 2. The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed instructions. The attachment system shall be UL 1703 approved tested. Provide water tight sealant at all penetrations. Attachments shall follow panel rows as specified by the system manufacturer’s installation manual. The panel angle shall match the roof slope. Reference summary table below: min. 5/16” x 4” long stainless-steel lags with a min. embedment of 3” into the rafters Shingle “UNIRAC NXT HORIZON 2-RAIL SYSTEM” Fastener Info: Fastener Max Spacing (in.) 48 48 48 August 12, 2024 Timothy Durbin 712 AMBERJACK LANE Certification: I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the manufacturers printed instructions. Michael S. Rezk Engineer-PE Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd South Plainfield, NJ 07080 Gravity Load Calculation Criteria Structural Design Loads per ASCE 7-22 Dead Loads = 10 psf + 2.6 psf (new solar panels) = 12.6 psf Roof Live Load = 20 psf Ground Snow Load/Live Load = 0 psf Wind Load Calculation Criteria Wind Loads per ASCE 7-22, Equation 29.4-7 Using an effective wind area of 10 SF, external pressure coefficient from Figure 30.3-A-I Zone 1 = -25.2 psf Roof Slope = 7 degrees Roof Mean Height = 15 ft Zone 2 = -33.8 psf Basic Wind Speed = 130 mph Zone 3 = -45.6 psf Exposure = B Per section 2.4.1, ASD combo = D + 0.6W: Zone 1 = 2.6 psf + 0.6(-25.2 psf) = -12.5 psf Zone 2 = 2.6 psf + 0.6(-33.8 psf) = -17.7 psf Zone 3 = 2.6 psf + 0.6(-45.6 psf) = -24.8 psf Check Attachment to Wood Truss Use 5/16 dia. Lag screw w/ 3" embedment into 2 in. wide roof rafter Lag Screw Spacing:Lag Screw Tributary Area: Zone 1 = 48" o.c. max Zone 1 = (48" o.c. max)^2 / 144 = 16 SF Zone 2 = 48" o.c. max Zone 2 = (48" o.c. max)^2 / 144 = 16 SF Zone 3 = 48" o.c. max Zone 3 = (48" o.c. max)^2 / 144 = 16 SF Lag Screw Forces:W = 266lb/in (Table 12.2A, 2015 NDS) Zone 1 = 12.5 psf x 16 SF = 200 lb < W', OK Cd = 1.6 (Table 2.3.2, 2015 NDS) Zone 2 = 17.7 psf x 16 SF = 283 lb < W', OK Ct = 1 (Table 2.3.3, 2015 NDS) Zone 3 = 24.8 psf x 16 SF = 397 lb < W', OK W' = W x embed x Cd x Ct W' = 266 lb/in x 3 in. x1.6 x 1 = 1276.8 lb August 12, 2024