712 AMBERJACK MCRS24-0014 TIMOTHY DURBIN - MS156156 FINAL DESIGN stamped_COVER PAGE PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US COVER PAGE SYSTEM INFORMATION MODULE HANWHA Q.PEAK DUO BLK ML-G10+ 410 INVERTER ENPHASE IQ8MC-72-M-US RACKING UNIRAC NXT HORIZON 2-RAIL RACKING SYSTEM SYSTEM SIZE (DC)4.92 KW LOCATION 30.3337665,-81.4095264 HANWHA Q.PEAK DUO BLK ML-G10+ 410 410 WATT MODULE74'' X 41.1'' X 1.26''(SEE DATASHEET) TABLE R301.2.1.3 WIND SPEED CONVERSIONSa Vult 110 115 120 130 140 150 160 170 180 190 200 Vasd 85 89 93 101 108 116 124 132 139 147 155 FBC, RESIDENTIAL 2023 For SI: 1 mile per hour = 0.447 m/s. a.Linear interpolation is permitted. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH)130 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B BILL OF MATERIALS MODULES 12 INVERTERS 12 L-FOOT ATTACHMENT W/ UNIRAC NXT 32 171" RAILS 6 SKIRTS 0 ENPHASE COMBINER BOX 1 EATON 60A FUSIBLE AC DISCONNECT 1 35A FUSES 2 20A BACKFEED BREAKER 1 PLAN KEY PV-1 COVER PAGE PV-1.1 ATTACHMENT DETAIL PV-1.1(2)ATTACHMENT DETAIL PV-1.2 INVERTER SPECS PV-1.3 COMBINER SPECS PV-1.4 PANEL SPECS PV-2 PANEL LAYOUT PV-3 ELETRICAL PV-3.1 ELECTRICAL CONT. PV-3.2 EQUIPMENT LABELS STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 8TH EDITION 2023 FLORIDA RESIDENTIAL CODE MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-22, 8TH EDITION 2023 FLORIDA RESIDENTIAL CODE, 8TH EDITION 2023 FLORIDA BUILDING CODE, 8TH EDITION 2023 FLORIDA FIRE PREVENTION CODE, NEC 2020 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY MICHAEL S. REZK, P.E. PROFESSIONAL ENGINEER, WITH LICENCE No. 95844. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2023 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 1 / 10 ATTACHMENT DETAIL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 2 / 10 ATTACHMENT DETAIL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1.1 (2) REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US ATTACHMENT DETAIL FOR SHINGLE ROOF Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 3 / 10 INVERTER DETAIL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 4 / 10 COMBINER DETAIL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1.3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 5 / 10 PANEL DETAIL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1.4 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 6 / 10 SCALE: 1/8" = 1'-0" ROOF LAYOUT PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW 12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US SYMBOL LEGEND MAIN SERVICE PANEL UTILITY METER SKYLIGHT VENT CHIMNEY SUB-PANEL MSP SP M AC DISC UDC LC N3R CB AC DISCONNECT LOAD CENTER NEMA 3R BOX W/ ENVOY-S COMBINER BOX PIPE VENT FAN SATELLITE DISH MODULE FIRE SETBACKS PITCH DIRECTION UTILITY DISCONNECT MIN 3'x3' GROUND ACCESS POINT WIND PRESSURE ZONE LINES. REFER TO PV-2.2 FOR ADDITIONAL INFO NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. 2. EXACT ATTACHMENT LOCATION AND QUANTITY OF ATTACHMENTS ARE BASED ON EXISTING RAFTER LOCATIONS OBTAINED FROM FIELD MEASUREMENTS. THE LOCATION AND QUANTITY OF ATTACHMENTS MAY VARY BASED ON RAFTER LAYOUT START POINT, SPACING VARIATIONS AND ROOFING TYPE. VERIFY IN THE FIELD ALL RAFTER LOCATIONS AND ADJUST LAYOUT AS REQUIRED. A TILE ROOF WILL PRODUCE A STAGGERED ATTACHMENT LAYOUT BECAUSE OF EXISTING STAGGERED TILE JOINT LOCATIONS. RAFTER SPACING 24" O.C. (TYP) CLAMPING MAX SPACING IN ZONE 1 48" O.C AND IN ZONE 2 AND ZONE 3 48" O.C LANDSCAPE MAX SPAN (ROOF AREA 1/2/3) PORTRAIT MAX SPAN (ROOF AREA 1/2/3) 48 /48 /48 48 /48 /48 48 /48 /48 48 /48 /48 ROOF PANEL COUNT TILT AZIMUTH SHADING R1 6 7°95°80% R2 6 7°275°74% TOTAL SQUARE FOOTAGE OF ROOF: 1719 SQFT SQUARE FOOTAGE OF SOLAR ARRAY:253.45 SQFT PERCENTAGE OF SOLAR ROOF COVERAGE: 14.75% 18" RIDGE SETBACK SHALL BE REQUIRED LANDSCAPE MAX CANTILEVER PORTRAIT MAX CANTILEVER 16 /10 /10 16 /10 /10 16 /10 /10 16 /10 /10 FRONT OF RESIDENCE AMBERJACK LANE DRIVEWAY 0'-91 2" 2'-81 2"3'-31 2"RIDGEGUTTERGUTTER3'-0" R1 R2 M AC DISC ELECTRICAL EQUIPMENT CB MSP GROUND ACCESS (TYP) FIRE SETBACK (36" VENTILATION, 36" ROOF ACCESS) (TYP) 0'-91 2" 3'-0" Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 7 / 10 TERMINATION CAP INSTALLED ON END OF CABLE =......10A/15A BREAKER (MANUFACTURER SUPPLIED FOR ENVOY) 20A BREAKER (A) ENPHASE 80A AC COMBINER BOX 1 2 3 == GND NEU ROOF JUNCTION BOX BRANCH CIRCUIT A12 MICRO-INVERTERS 12 HANWHA Q.PEAK DUO BLK ML-G10+ 410 410W MODULES PAIRED WITH 12 ENPHASE IQ8MC-72-M-US MICRO-INVERTERS GND BUS NEU BUS POWER GROUND EXISTING GENERAL ELECTRIC 200A MAIN SERVICE PANEL 240 V MAIN BREAKER: 200A 200A UTILITY METER GRID 20A 35A FUSES GND NEU 3 EATON 60A FUSIBLE AC DISCONNECT 35A 35A FUSES SOLAR CIRCUIT DISCONNECTING MEANS Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp. Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A)NEC Correction Design Current (A) Ground Size Ground Wire Type 1 OPEN AIR 1 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 12 1.33 1.25 19.95 12 AWG Trunk Cable 2 3/4" PVC 2 10 AWG THWN-2 75°C 35 0.96 1 33.60 12 1.33 1.25 19.95 08 AWG THWN-2 3 3/4" PVC 3 + G 08 AWG THWN-2 75°C 50 0.96 1 48.00 12 1.33 1.25 19.95 08 AWG THWN-2 THREE LINE DIAGRAM SUB PANEL BREAKER SIZE # OF MODULES PV BREAKER PER BRANCH UP TO 16 20A PV MODULE RATINGS MODULE MAKE HANWHA MODEL HANWHA Q.PEAK DUO BLK ML-G10+ 410 MAX POWER 410W OPEN CIRCUIT VOLTAGE 45.37V MPP VOLTAGE 37.64V SHORT CIRCUIT CURRENT 11.2A MPP CURRENT 10.89A NUMBER OF MODULES 12 UL1703 COMPLIANT YES INVERTER RATINGS INVERTER MAKE ENPHASE MODEL Enphase IQ8MC-72-M-U S MAX OUTPUT POWER 320W OPEN DC VOLTAGE 60V NOMINAL AC VOLTAGE 240V MAX AC CURRENT 1.33A CEC INVERTER EFFICIENCY 97% NUMBER OF INVERTERS 12 UL1703 COMPLIANT YES VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC HANDBOOK 215.2(A)(4) WHERE APPLICABLE WIRE RUN Vmp Imp R L (FT)Vo % Vo WIRE SIZE BRANCH TO J-BOX 240.00 J-BOX TO LOAD CENTER 240.00 LOAD CENTER TO AC DISCONNECT 240.00 AC DISCONNECT TO INTERCONNECTION 240.00 15.96 1.98 79.00 4.993 2.08%12 AWG 15.96 1.24 50.00 1.979 0.82%10 AWG 19.95 0.778 3.00 0.093 0.04%08 AWG 19.95 0.778 10.00 0.310 0.13%08 AWG PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW 12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. NEC 705.12(B)(2)(3)(b) 120% RULE (1.25 x INVERTER OUTPUT) + MAIN OCPD ≤ BUS RATING x 1.20 (1.25 x 15.96) + 200 ≤ 200 x 1.20THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2023 FLORIDA BUILDING CODE AND THE 2020 NATIONAL ELECTRICAL CODE FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2023 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 8 / 10 ELECTRICAL CONT. PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW 12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US ELECTRICAL NOTES: MAKE MODEL VOLTAGE RATING CONDUCTOR RANGE MAIN CONDUCTOR RANGE TAP ILSCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4020 600 V 4/0-2 AWG 2/0-6 AWG TABLE 1: INSTRUCTIONS FOR LINE TAPS FIGURE 1: 1.ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2.PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3.INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4.TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5.SCREW THE NUT WITH THE SLEEVE SPANNER. 6.SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN 1.ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFFICIENTS. 2.THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.43(A) THROUGH (D) WITH 250.134 OR 250.136. 3.THIS SYSTEM COMPLIES WITH NEC 2020 4.BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2020 ARTICLE 310 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7.INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8.CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9.EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10.ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 11.PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. 12.PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13.INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14.AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB-CIRCUIT BRANCHES IS ACCEPTABLE. 15.ALL CONDUCTORS MUST BE COPPER. 16.NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17.EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18.FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19.SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20.METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22.WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25.TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.51. 28.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29.ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30.NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13(B), 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.11(A) THROUGH (E) OR 705.12(B) THROUGH (E) 32.ALL WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 2020 NEC ARTICLE 110.21(B). LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. 33.PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 9 / 10 ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING 15.96 QUANTITY LOCATION A LABELTAG B C D E F 1 1 JUNCTION BOX INTERCONNECTION POINT 1 UTILITY METER 1 COMBINER BOX 1 AC DISCONNECT (RSD SWITCH) 1 AT ANY COMBINER BOX 1 AT ANY JUNCTION BOX 1 OF EACH AT FUSED AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL 1 OF EACH AT BUILDING INTERCONNECTION POINT AND ONE DIRECTORY PLACARD 1 AT UTILITY METER AND ONE DIRECTORY PLACARD NOTE EXAMPLES A B D REVENUE METER C RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE A 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR GENERATION AC SYSTEM DISCONNECT DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING WARNING: PHOTOVOLTAIC POWER SOURCE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 1 AC SOLAR VOLTAGE G 12 AC CONDUITS 1 AT EVERY SEPARATION BY ENCLOSURES / WALLS / PARTITIONS / CEILINGS / FLOORS OR NO MORE THAN 10' F G BACKFEED DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING NOMINAL OPERATING AC VOLTAGE : 240V NOMINAL OPERATING AC FREQUENCY : 60HZ MAXIMUM AC POWER : VA MAXIMUM AC CURRENT : A MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION : 20A AC CURRENT PV MODULES 1 BACKFEED PANEL H CAUTION CAUTION POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING PHOTOVOLTAIC SYSTEM INSTALLED BY MOMENTUM SOLAR 3096 B HAMILTON BLVD S. PLAINFIELD, NJ 07080 PHONE NUMBER:732-902-6224 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM SOLAR ELECTRIC PV PANELS SECTIONS OF THE PV SYSTEM THATARE SHUT DOWN WHEN THE RAPIDSHUTDOWN SWITCH IS OPERATED SECTIONS OF THE PV SYSTEM THATARE NOT SHUT DOWN WHEN THE RAPID SHUTDOWN SWITCH IS OPERATED EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN EQUIPMENT LABELS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING TIMOTHY DURBIN - MS156156 712 AMBERJACK LANE ATLANTIC BEACH, FL 32233 (904) 903-1224 KJL CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 8/12/2024 SYSTEM SIZE (DC ): 4.92 KW 12 MODULES: HANWHA Q.PEAK DUO BLK ML-G10+ 410 12 INVERTERS: ENPHASE IQ8MC-72-M-US ALL WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC ARTICLE 110.21(B). LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2024.08.12 05:08:27 -05:00 Powered by TCPDF (www.tcpdf.org) 10 / 10