606 Aquatic Dr RES24-0206 PermitOWNER:ADDRESS:CITY:STATE:ZIP:
BENNETT RANDEL 5187 CLAPBOARD CREEK DR JACKSONVILLE FL 32226
COMPANY:ADDRESS:CITY:STATE:ZIP:
LAVENDER HOUSE
EXTERIORS LLC 450 Pablo Point Drive Jacksonville FL 32225
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171818 5202 AQUATIC GARDENS
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
606 AQUATIC DR RESIDENTIAL SIDING HARDIE LAP SIDING OVER T1
-11 $12000.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $115.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.59
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $177.09
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/3/2024
PERMIT NUMBER
RES24-0206
ISSUED: 10/3/2024
EXPIRES: 4/1/2025
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
2 of 2Issued Date: 10/3/2024
PERMIT NUMBER
RES24-0206
ISSUED: 10/3/2024
EXPIRES: 4/1/2025
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing Dry-In
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In -Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before
any work is covered up.
* When all gas piping is complete and wallboard is installed but before
gas is attached to any appliance. All outlets must be capped and pipe
pressurized at a minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department - Phone: 904-247-5826 - Email: Building-Dept@coab.us
Public Works/Utilities - Phone: 904-247-5834
Fire Department - Phone: 904-630-4789
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are
complete, but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $177.09
RES24-0206 Address: 606 AQUATIC DR APN: 171818 5202 $177.09
BUILDING $115.00
BUILDING PERMIT 455-0000-322-1000 0 $115.00
BUILDING PLAN REVIEW $57.50
BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50
STATE SURCHARGES $4.59
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.59
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R28618 $177.09
Printed: Thursday, October 3, 2024 4:10 PM
Date Paid: Thursday, October 03, 2024
Paid By: LAVENDER HOUSE EXTERIORS LLC
Pay Method: CREDIT CARD 10328425879
1 of 1
Cashier: KW
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R28618
t BUILDING PERMIT APPLICATION FOR INTERNAL OFFICE USE ONLY
moi 1. City of Atlantic Beach Building Department PERMIT# RAS zq- dz dw
800 Seminole Road, Atlantic_Beach .FL.3223.3
r
FALL information required to process
Phone: (904) 247-5826 Email: Building-DeptPcoab.us
Job Address (gyp(, /C{ ),.-c -I)rlvt Mlarck Beach 32233 RE# /'7/ g/8 -5QO.Z
Legal Description 38 -'71 i'7"-ZS --2' E . 110 A9 ua-i- G,aro(t,r 3 PT Lo-+ 13-4,)2-D RE CP o/R. /SS 75"16,72
Valuation of Work(Replacement Cost) j Q,,coo Heated/Cooled SF I A 1 5 Non-Heated/Cooled SF 3 a,
Class of Work: New Addition ®Alteration ['Repair ['Move EDemo E Pool Window/Door
Use of existing/proposed structure(s): ECommercial ®Residential
If an existing structure, is a fire sprinkler system installed?: Yes No
Will tree(s)be removed in association with proposed project? Eyes(Must submit separate Tree Removal Permit) ®No
Describe in detail the type of work to be performed:
14ArLT>>6 L'"p S`t , - to Oven- E.1,%%'tt .C, ' -1 .- 11 .
Florida Product Approval# 3 l i a, ,;- For multiple products use Product Approval Information Sheet)
Property Owner Information Name Ter' $cr\ne.+-4 Phone 9o4. .24o. 5..7 97
Address bo(G Ac -bc IS)Y kyr City A}bhctic ZCAck State "FL Zip 3 Z.2 3 3
Email mrmrS berinc @dk Z !k} Owner or Agent(If Agent, Power of Attorney or Agency Letter Required)
Contractor.Information Name of Company .ti.vcr,oto - -{461,lSc. Phone cloy 553.892(.
Address 15o Pablo 'TO1nt --1;r vt City tTackSOhvi l k State "FL Zip 32 Z .25
Qualifying Agent NA.}y,o,,., L,0,y,-L6 .r + State Certification/Registration# 13 3 3 0 z Z
Email NLv.mber eAvevYi1C+ oust Cm-rind-1 cvm Job Site Contact Number cloy.553. 129 il
Worker's Compensation Insurer OR Exempt Dl Expiration Date 5/ (, 1.25
Architect's Name Email Phone
Engineer's Name Email Phone
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may
be found in the public records of this county, and there may be additional permits required from other governmental entities
such as water management districts, state agencies, or federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH Y UR LENDE OR AN
Ai I RNEY BEFORE RECORDING Y O(R NOTICE OF COMMENCEMENT.
X C illi
JSt n ture of Owner or Agent) 172_ Signature of Contractor)
Signed and sworn to(or affirmed) before me this / day of Signed and sworn to(o .ffirmed) before me this Z day of
bG, b P, ro/ i
r> Y ttlill I y L. . . 'h . L0. bp
Signature of Notary i • i
e Signature of Notary
I Personally Known _ OR [ 1-P,vduced Identifica •3 I Personally Known OR [ I Produced 4 entiflcation
p
Type of Identification:V/ 75 / 7 / Type of Identification: ~ _
AIMAM• z°.J`.0 TONI GINDLESPERGERp
Notary Dublk•Stag .. ...t i„r MY COMMISSION#HH 407122
i,- Commission I MM 560181 nom..o;
r.; _ FaFi,,%.•: EXPIRES:October 6,2027
Av
ir
11i 14—/L40.1
11. W
HardiePlank` Lap Siding
EFFECTIVE DECEMBER 2019
IMPORTANT:FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATION INSTRUCTIONS AND COMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS,AFFECT
BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE.FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTTING AND INSTALLING
THIS PRODUCT MAY RESULT IN PERSONAL INJURY.BEFORE INSTALLATION,CONFIRM YOU ARE USING THE CORRECT HARDIEZONE'PRODUCT INSTRUCTIONS BY VISITING
HARDIEZONE.COM OR CALL 1-866-942-7343(866-9-HARDIE)
CUTTING INSTRUCTIONS
STORAGE & HANDLING: OUTDOORS INDOORS
1.Position cutting station so that airflow blows dust away Irom Vie DO NO I grind or cut with a power saw ndoo•s.Cut using shears(manual,pneumatic orStoreflatandkeepdryandcoveredpriortouserandothersnearthecuttingarea. electric)or the score and snap method,not recommended for products thicker than 7/16 in.
installation.Installing siding wet or saturated may 2.Cut using one of the following methocs:
result in shrinkage at butt joints.Carry planks on
a.Best: Circular saw equipped with a-ardieBlade r saw blade
and attached vacuum dust collection system.Shears - DO NOT dry sweep dust;use wet dust suppression or vacuum to collect dust.
edge. Protect edges and corners from breakage. manual,pneumatic or electrc)may also be used.not - For maximum dust reduction,James Hardie recommends using the"Best'cutting
James Hardie is not responsible for damage caused recommended for prod..cts thicker than 7/16 in.practices.Always follow the equipment manufacturer's instructions for proper operation.
by improper storage and
b.Better: Circular saw equipper with a oust collection'entre - For best performance when cutting with a circular saw.James Hardie recommends
a
e.g.Roan saw)and a HardieBladede saw blade.
using HardieBladeg'saw blades.handling of the C.Good: Circular saw equipper with a-ardieBlade saw utero.
product. Go to jameshardiepros.com for adrift onal cutting and dust control recommendations.
i IMPORTANT:The Occu tonal Safe and Health Adminstratior(OSHA regulates—y pa ty g workplace exposure to silica dust. For construction sites.OSHA has deemed
Mat cutting fiber cement witrr a circular saw having a blade diameter less than 8 inches and connected to a ca'mterc ally available dust collection system per
manufacturer's instructions results m expos,;res below the CS-A Permissible Exposure Limit(PEL)for respirable crystalline silica.wit^out the need for additional
respiratory protection.
It you are unsure about now to comply w:h OSHA silica ccs regulations.consult a qualified industrial hygienist or sa`oly professional.or contact your James
Hardie technical sales representat ve'o'assistance.James Hardie makes no representation or warranty that adopting a part cular cutting practice will assure
your compliance with OSHA rules or other appl.cable laws and safety requirements.
GENERAL REQUIREMENTS:
HardiePlankn lap siding can be installed over braced wood or steel studs,20 gauge(33 mils)minimum to 16 gauge(54 mils)maximum,spaced a maximum of 24 in o.c.or directly to
minimum 7/16 in thick OSB sheathing.See General Fastening Requirements.Irregularities in framing and sheathing can mirror through the finished application.Correct irregularities
before installing siding.
Information on installing James Hardie products over non-nailable substrates lex:gypsum,foam,etc.)can be located in JH Tech Bulletin 19 at www.jamehardie.com
A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing
in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration.James Hardie does manufacture HardieWrapu Weather Barrier,a
non-woven non-perforated housewrap',which complies with building code requirements.
When installing James Hardie products all clearance details in figs.3-14 must be followed. Double Wall Figure 1 Single Wall
Adjacent finished grade must slope away from the building in accordance with local building codes-typically a minimum Construction Construction
of 6 in.in the first 10 ft.. water-resistive let-n gracing
Do not use HardiePlank lap siding in Fascia or Trim applications.
barrier
plywood or
24 rn o.c.
Do not install James Hardie products,such that they may remain in contact with standing water. OSB sh\hngHardiePlanklapsidingmaybeinstalledonflatverticalwallapplicationsonly. IForlargerprojects,including commercial and multi-family projects,where the span of the wall is 141441114 -10/,,
significant in length.the designer and/or architect should take into consideration the coefficient of thermal expansion and
moisture movement of the product in their design.These values can be found in the Technical Bulletin"ExpansionCharacteristicsofJamesHardie°Siding Products"at www.jameshardie.com.
James Hardie Building Products provides installation/wind load information for buildings with a maximum mean roof
height of 85 feet.For information on installations above 60 feet,please contact JH technical support.
jINSTALLATION: JOINT TREATMENTFigure 2 rOneormoreofthefollowingjointtreatmentoptions
arereuiredbcodeasreferenced2009IRCR703.10.2 stud Nail line Of rail line is rotaqY ( present.place tas:ener
A.Joint Flashing(James Hardie recommended) tqm . between Vac r.&t r 0 water-resistive
B.Caulking*(Caulking is not recommended
nom top of plank) r,o
Mr ColorPlus for aesthetic reasons as the Caulking -'; '".. Nail 3/8 in,irony o 1 fas*error
ec a of plankandColorPluswillweather
mint .„,„
e-
i. '.
9 d u Install a 4 in.starter strip to
differently.For the same reason. trashing Leave appropriate gap between
ensure a consistent plank angle
do not caulk nail heads on Install planks in
planks and trim,then caulk.'
moderate contact
ColorPlus products.) a:but:joints
C."H" jointer cover S JamesHardie
Note:Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus.*Beier to Caulking section in these instructions.
For additional information on HardieWrap an Weather Barrier.consult James Hardie at 1-866-4Hardie or www.hardiewrap.com
SELECT CEDARMILL° I SMOOTH I BEADED CEDARMILL° I BEADED SMOOTH I CUSTOM COLONIAL SMOOTH° I CUSTOM COLONIAL'"ROUGHSAWN
Visit jameshardiepros.com for the most recent version. HS11119 P1/4 12/19
Hry
HardiePlank- Lap Siding
CLEARANCE AND FLASHING REQUIREMENTS
Figure 3 Figure 4 Figure 5 Figure 6
Roof to Wall Horizontal Flashing Kickout Flashing Slabs, Path, Steps to Siding
li -- Z Flashing
7
As wiredry•
code°
4Yt x 4 in.
koirr."—. •-
a
Min.1/4 in. i wtt
Do not caulk,
i jttitiot'. Nk.," _.,...
k.. 40.,,,,
IIi . 4.11\ - in.'
1 in.I
rtr7.
16,._-,,..._, Alb'
Figure 7 Figure 8 Figure 9 Figure 10 Figure 11
Deck to Wall Ground to Siding Gutter to Siding Sheltered Areas Mortar/Masonry
j '-,s c L Flashing
Z-Flashingv-Fhing/ Z-Flashing
4,10r ..K
io
Vell
6 in.
6.44c.,
Min.1/2 in.
C '—1000°°.:_..4—
P1.--
141
ell
n.-'/4 in.
401111.
Figure 12 Figure 13 Figure 14
Drip Edge Block Penetration Valley/Shingle Extension
Recommended in H711)J
u,. .
Z Flea bid
ir
Extend shingl.
Min.Y4 I r atleast1 in.
11Aloi
from the fascia'
whenegutters
00°,---`". are present
adig°101*1. 111‘.-
FASTENER REQUIREMENTS*
I Refer to the applicable ESR report online to determine which fastener meets your wind load design criteria.
Blind Nailing is the preferred method of installation for HardiePlank,','lap siding products.Face nailing should only be used where required by code for high wind areas and must not
be used in conjunction with Blind nailing(Please see JH Tech bulletin 17 for exemption when doing a repair).
BLIND NAILING FACE NAILING
Nails-Wood Framing Nails-Wood Framing
Siding nail(0.09 in.shank x 0.221 in.HD x 2 in.long) 6d(0.113 in.shank x 0.267 in.HD x 2 in.long)
11 ga.roofing nail(0.121 in.shank x 0.371 in.HD x 1.25 in.long)Siding nail(0.09"shank x 0.221"HD x 2"long)
Screws-Steel Framing Screws-Steel Framing
Ribbed Wafer-head or equivalent(No.8 x 1 1/4 in.long Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8 in.long x
x 0.375 in.HD)Screws must penetrate 3 threads into metal framing. 0.323 in.HD)Screws must penetrate 3 threads into metal framing.
Nails-Steel Framing Nails-Steel Framing
ET&F Panelfast- nails or equivalent(0.10 in.shank x 0.313 in.HD x 1-1/2 in.long)ET&F pin or equivalent(0.10 in.shank x 0.25 in.HD x 1-1/2 in.long)
Nails must penetrate minimum 1/4 in.into metal framing. Nails must penetrate minimum 1/4 in.into metal framing.
OSB minimum 7/16 in. OSB minimum 7/16 in.
I •Siding nail(0.09 in.shank x 0.215 in.HD x 1-1/2 in.long Siding nail(0.09 in.shank x 0.221 in.HD x 1-1/2 in.long)
Ribbed Wafer-head or equivalent(No.8 x 1 5/8 in.long x 0.375 in.HD).
Also see General Fastening Requirements:and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 5-Fastening Tips for HardiePlank Lap Siding.
1611119 P2/4 12/19
49111712V
HardiePlank"Lap Siding
FASTENER REQUIREMENTS continued
24
Pi
Figure 15 Figure 16 Stud 0 C max
Stud 24
O.C.max r
1
Joint 1 1!4'min.
Minimum overlap Flashing
n Overlap
1- • for Both Face
i
3L-i.- and Blind Nailing r•T`_
Nail Line
r
oi) Blind Nail min.1 1/4 in. '
I — Face Nail
T I
overflap
III
Water Resistive
Water Resistive Barrier
1 1/4"min. I ` Barrier
Overlap
Laminate sheet to be removed immediately after installation of each course for ColorPlus'v products.
IPin-backed corners may be done for aesthetic purposes only.Finish nails are recommended for pin-backs.Headed siding nails are allowed.Place pin-backs
no closer than 1 in.from plank ends and 3/4 in.from plank edge into min.3/8 in.wood structural panel.Pin-backs are not a substitute for blind or face nailing.
GENERAL FASTENING REQUIREMENTS PNEUMATIC FASTENING
Fasteners must be corrosion resistant,galvanized,or stainless steel.Electro-galvanized James Hardie products can be hand nailed or fastened with a pneumatic tool.
are acceptable but may exhibit premature corrosion. James Hardie recommends the Pneumatic fastening is highly recommended. Set air pressure so that the
use of quality,hot-dipped galvanized nails.James Hardie is not responsible for the fastener is driven snug with the surface of the siding.A flush mount
corrosion resistance of fasteners.Stainless steel fasteners are recommended when attachment on the pneumatic tool is recommended. This will help control the
installing James Hardie products near the ocean,large bodies of water,or in
veryCO
this tt
humid climates.
prodepthves difficult,
nail
choosedriven.
a
settinging thatthe underdepth
drives031thenail.
e(
Drive under drivenIfsenails
snugnail
with a
Manufacturers of ACO and CA preservative-treated wood recommend spacer materials
smooth faced hammer Does not apply for
or other physical barriers to prevent direct contact of ACQ or CA preservative-treated SNUG FLUSH installation to steel framing).
wood and aluminum products.Fasteners used to attach HardieTrim Tabs to preserva-
tive-treated wood shall be of hot dipped zinc-coated galvanized steel or stainless steel
and in accordance to 2009 IRC R317.3 or 2009 IBC 2304.9.5 DO NOT DO NOT DO NOT USE
Consult applicable product evaluation or listing for correct fasteners type and gilt Itlitplacementtoachievespecifieddesignwindloads. oNOTE:Published wind loads may not be applicable to all areas where Local Building
Codes have specific jurisdiction.Consult James Hardie Technical Services if you are
UNDER OVER SLANT ALUMINUM
unsure of applicable compliance documentation. DRIVE DRIVE FASTENERS
Drive fasteners perpendicular to siding and framing.
Fastener heads should fit snug against siding(no air space). IF,THEN IF,THEN ADDITIONAL NAIL
NOTE:Whenever a structural member is present,HardiePlank should be fastened with
even spacing to the structural member.The tables allowing direct to OSB or plywood WOOD STEEL FACE
CLIPPED
should only be used when traditional framing is not available. FRAME FRAME NAIL
HEAD NAILS
CUT EDGE TREATMENT
1I
Caulk,paint or prime all field cut edges.James Hardie touch-up kits are required to
touch-up ColorPlus products.L.i COUNTERSINK
STAPLES
CAULKING HAMMER
FLUSH
FILL
For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, REMOVE&
Class 25 or higher or a Latex Joint Sealant complying with ASTM C834.Caulking/Sealant REPLACE
must be applied in accordance with the caulking/sealant manufacturer's written instructions.
Note:some caulking manufacturers do not allow"tooling".
PAINTING
DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie Products.Factory-primed James Hardie products must be painted within 180 days of installation.
100%acrylic topcoats are recommended.Do not paint when wet.For application rates refer to paint manufacturers specifications.Back-rolling is recommended if the siding
is sprayed.
H511119 P3/4 12/19
yro
i HardiePlank` Lap Siding
t.1
COLORPLUS`m TECHNOLOGY CAULKING,TOUCH-UP & LAMINATE
Care should be taken when handling and cutting James Hardie')ColorPlus-products.During installation use a wet soft cloth or soft brush to gently wipe oft any
residue or construction dust left on the product,then rinse with a garden hose.
Touch up nicks,scrapes and nail heads using the ColorPlus"Technology touch-up applicator.Touch-up should he used sparingly.
If large areas require touch-up,replace the damaged area with new HardiePlank a lap siding with ColorPlus°'Technology.
Laminate sheet must be removed immediately after installation of each course.
Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPluse'product dealer.
Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer.
Note:James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered
under the James Hardie ColorPlus Limited Finish Warranty.
PAINTING JAMES HARDIER SIDING AND TRIM PRODUCTS WITH COLORPLUS®TECHNOLOGY
When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application:
Ensure the surface is clean,dry,and free of any dust,dirt.or mildew
Repriming is normally not necessary
100%acrylic topcoats are recommended
DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie'"Products.
Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature
DO NOT caulk nail heads when using ColorPlus products,refer to the ColorPlus touch-up section
COVERAGE CHART/ESTIMATING GUIDE
Number of 12 ft.planks,does not include waste
COVERAGE AREA LESS f NINGS 51/4 61]4
RDIEINK"tpf/2SIDIN91WIDTH
81/4 91/4 91/2 12
1 SO=100 sq.tt.) (exposure) 4 5 6 61/4 6 3/4 7 8 81/4 10 3/4
1 25 20 17 16 15 14 13 13 9
2 50 40 33 32 30 29 25 25 19
3 75 60 50 48 44 43 38 38 28
4 100 80 67 64 59 57 50 50 37
5 125 100 83 80 74 71 63 63 47
6 150 120 100 96 89 86 75 75 56
7 175 140 117 112 104 100 88 88 65
8 200 160 133 128 119 114 100 100 74
9 225 180 150 144 133 129 113 113 84
10 250 200 167 160 148 143 125 125 93
11 275 220 183 176 163 157 138 138 102
12 300 240 200 192 178 171 150 150 112
13 325 260 217 208 193 186 163 163 121
14 350 280 233 224 207 200 175 175 130
15 375 300 250 240 222 214 188 188 140
16 400 320 267 256 237 229 200 200 149
17 425 340 283 272 252 243 213 213 158
18 450 360 300 288 267 257 225 225 167
19 475 380 317 304 281 271 238 238 177
20 500 400 333 320 296 286 250 250 186
This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibility for over or under
ordering of product.
HS11119 P44 1219
0
DANGER:May cause cancer if dust from product is inhaled.Causes damage to lungs and respiratory system through prolonged or repeated inhalation of dust from product.Refer to the current product Safety Data Sheet before use.
The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting,machining.drilling,routing.sawing,crushing.or otherwise abrading fiber cement.and when cleaning
up.disposing of or moving the dust.When doing any of these activities in a manner that generates dust you must(1)comply with the OSHA standard for silica dust and.or other applicable law,(2)follow James Hardie cutting
instructions to reduce or limit the release of dust,(3)warn others in the area to avoid breathing the dust;(4)when using mechanical saw or high speed cutting tools,work outdoors and use dust collection equipment:and(5)it no
other dust controls are available,wear a dust mask or respirator that meets NIOSH requirements(e.g.N-95 dust mask).During clean-up.use a well maintained vacuum and filter appropriate for capturing fine(respirable)dust or use
wet clean-up methods-never dry sweep.
1k WARNING:This product can expose you to chemicals including respirable crystalline silica,which is known to the State of California to cause cancer.For more information go to P65Warnings.ca.gov
RECOGNITION:I In accordance with ICC-ES Evaluation Report ESR-2290.HardiePlank w lap siding is recognized as a suitable alternate to that specified in the 2006.2009,2012&2015 International Residential Code for One and Two-Family
Dwellings,and the 2006.2009.2012&2015 krternatkinal Building Code.HardiePlank lap siding is also recognized for application in the following.City of Los Angeles Research Report No.24662,State of Florida Product Approval FLe13192,
Miami-Dade County Florida NOA No.17-0406.06.U.S.Dept.of HUD Materials Release 1263f,Texas Department of Insurance Product Evaluation EC-23.City of New York MEA 223-93-M.and California DSA PA-019.These documents should
Iso be consulted for additional information concerning the suitability of this product for specific applications.
ci 2018 James Hardie 8itairg Fod.rcts Inc.All'of Is reserreo TM.SM and.q Product warranties,safety information and additional installation OD Ja roesHardiedenotetrademarksorrenis:e'ea trademarks of James Hardie Techaolo4)t'wiled. information are available at jameshardiepros.com