1726 ATLANTIC ROW24-0041 JB2004978-CADCOMCAST PERMIT REQUEST FOR LOCATION:1726 ATLANTIC BEACH DR, ATLANTIC BEACH, FL 32233THESE PLANS WERE PREPARED UNDER THERESPONSIBLE CHARGE OF COMCAST.SANTA ROSAOKALOOSAWALTONHOLMESWASHINGTONBAYCALHOUNJACKSONGADSDENLIBERTYGULFFRANKLINWAKULLALEONJEFFERSONTAYLORMADISONHAMILTONSUWANNEELAFAYETTEDIXIEGILCHRISTCOLUMBIAUNIONBAKERBRADFORDALACHUALEVYMARIONPUTNAMCLAYDUVALNASSAUST JOHNSFLAGLERVOLUSIALAKESUMTERCITRUSORANGESEMINOLEOSCEOLAPASCOHERNANDOPOLKHILLSBOROUGHPINELLASINDIAN RIVERBREVARDST LUCIEMARTINOKEECHOBEEHIGHLANDSHARDEEMANATEESARASOTADESOTOGLADESCHARLOTTELEEHENDRYPALM BEACHBR/WARDCOLLIERMIAMI-DADEMONROEESCAMBIAINDEX·Sheet 1:·Sheet 2:·Sheet 3-4:·Sheet 5-7:Cover-TitleNotes & SymbologyConstruction Plans (Atlantic Beach Dr)MOTVICINITY MAPNO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDDUVAL COUNTYWORK LOCATIONATLANTIC BEACH DRATLANTIC B
EACH
C
T
NO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDGENERAL NOTES:ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36" .ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BOREMACHINE, AS WELL AS COUNTY APPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PIT AND WILL USE 2" HDPE CONDUIT AT 36" DEPTH USING A 51/4" DRILL HEAD.ALL PROPOSED AERIAL WILL BE 0.700" DIAMETER AND WILL BE LASHED TO 0.250" STEEL STRAND CABLEUSING 0.125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROAD/WAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TOCONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTERCONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITHBERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OFWORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONINGEQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THECONTRACTOR.CONSTRUCTION NOTES:IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THERIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIESCAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES INCASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THECASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THEDRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACTWITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALLNOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATORSHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THEEXISTING FACILITIES OF THE OTHER UTILITY COMPANIESNO REAMER USEDTHE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITHTHE FLORIDA DEPARTMENT OF TRANSPORTATION 2024-2025INDEX 102-602 & 102-660 AND APPLY TO:1726 ATLANTIC BEACH DR, ATLANTIC BEACH, FL 32233BORE PITGAS/WATER/SS/ELECTRIC VALVETREE/BUSHESEXISTING POLEEXISTING COMCAST PEDESTALNEW RISER ATTACHED TO POLEEXISTING IRRIGATION VAULTEXISTING COMCAST VAULTEXISTING UTILITY VAULT/PEDESTALNEW COMCAST LOW PROFILE NEW COMCAST PEDESTALNEW COMCAST VAULTPOWER SUPPLY W/ METERPHMONUMENTUNIDENTIFIED MANHOLEWATER METERSTORM DRAIN MANHOLESANITARY / STORM SEWER MANHOLECATCH BASINSEWER CLEAN OUTWATER MANHOLEELECTRIC MANHOLETRANSFORMERFIRE HYDRANTTRAFFIC SIGNAL COMBINATIONSTREET LIGHTGAS METERPOTHOLESTREET SIGNNEW POLETELCO MANHOLECULVERTROADWAY CENTER LINEEXISTING CATV LINEEXISTING FENCELINEEXISTING WATER LINEEXISTING STORM DRAINEXISTING SANITARY SEWEREXISTING IRRIGATION SYSTEMEXISTING GAS SYSTEMEXISTING ELECTRICAL SYSTEMEXISTING TELEPHONE SYSTEMPROPERTY LINELINETYPESPROPOSED BORE ROUTEPROPOSED AERIAL ROUTEEASEMENT LINER/W LINEBOCRAILROAD
NO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDSEE MATCHLINE ON SHEET- 4ATLANTICBRACH DR CT84' ± TOR/WBOCC/LBOCR/W1762175617501744173817321726172017211727173317391745175152'D/WD/WD/WD/WD/WD/WD/WATLANTIC BEACH DRD/WD/WD/WD/WD/WD/WD/WD/WD/W24'
14
'13'12'5'2'
50'R/WC/LBOCR/W26'BOCBOCC/LBOC0+061+271+392+562+680+00BEGIN UG HEREEXISTING CATV PED #14' S/W1
1
'8'
5
'6'115'117'121'1+33EXISTING CATV PED #25'8'R/WR/W50'24'13'13'2+62EXISTING CATV PED #23+89STING CATV PED #26'6'6'6'50'R/W
R/WC/LR/W
R/W
0''12''24''36''48''60''72''84''96''108''0''12''24''36''48''60''72''84''96''108''24'SD
WATER
SEWER 13'12'15'13'EOP EOP
EOPEOP4'S/W12'5'5'
NO EXPECTED CONFLICTS WITH OTHER UTILITIESNO BACKREAMER USEDSEE MATCHL
INE
ON
SHEET
-
3DEAD END1075' ± TOATLANTIC BEACH DRR/WBOCC/LBOCR/W1787178117861780177417751769176317681762175617451751175724'13'13'D/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/W5
0
'6+62R/WC/LBOCR/W2
6
'BOCBOCC/LBOC5+385+242+562+683+833+957+02END UG HEREEXISTING CATV PED #64' S/W50'12'5'15'5'12'PROPOSED BORE PLACEMENTFOR 702' ALONGATLANTIC BEACH DRAT MIN DEPTH OF 36"USING 1-2" 13.5 SDR ROLL PIPEWITH 24 CT FOC40'124'129'115'13'
5
'
8
'R/WR/W50'
24
'13'RAISE MEDIANRAISE MEDIAN3+89EXISTING CATV PED #25+31EXISTING CATV PED #26'7'50'R/W
R/WC/LR/W
R/W
0''12''24''36''48''60''72''84''96''108''0''12''24''36''48''60''72''84''96''108''24'SD
WATER
SEWER 13'12'15'13'EOP EOP
EOPEOPCATV @36"5'4'S/W12'5'
OF 7
OF 7
OF 7