Loading...
299 ATLANTIC BLVD UNIT 1 COMM24-0039 ANGIES AB PLAN REVISION 11-13-24D1 DEMOLITION PLANANGIE'S SUBS RENOVATION299 ATLANTIC BLVD.ATLANTIC BEACH, FL 32233F O R M S P A C E , I N C DATE ISSUED: SEPTEMBER 19, 2024 CONSULTANT: REVISIONS: SHEET TITLE SHEET NUMBER PERMIT SET ARCHITECT: 200 FIRST STREET SUITE 205 NEPTUNE BEACH, FLORIDA 32266 design@200firststreet.com 904-535-0270 ph 904-246-8402 fax JNOverby , LLC ARCHITECTURE ∙ INTERIOR DESIGN Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville, Florida 32550 904∙704∙8628 JNO@JNOVERBY.COM FL. AR-0017060 ∙ FL. ID-4621 EXISTING DEMOLITION FLOOR PLAN SCALE: 3/16" =1'-0" EXISTING DEMISING WALL TO REMAIN GENERAL DEMOLITION NOTES: 1.ALL DEMOLITION WORK TO BE PERFORMED UNDER G.C. CONTRACT. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS. 2.SURVEY EXISTING CONDITIONS OF THE BUILDING TO DETERMINE IF REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY TO ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER IN WRITING PRIOR TO COMMENCING ANY ADDITIONAL WORK FOR DIRECTION IF DEFICIENCIES ARE NOTED. 3.TURN OFF NECESSARY POWER AND UTILITIES PRIOR TO COMMENCING ANY DEMOLITION WORK. 4.ITEMS INDICATED TO BE REMOVED SHALL BE REMOVED AND LEGALLY DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES. 5.PROTECT EXISTING ITEMS TO REMAIN. THESE ITEMS INCLUDE CITY SEAL AND 2 DOORS. REMOVE AND PROTECT EXISTING SECURITY DOORS AS NOTED ON PLAN, INCLUDING HARDWARE AND WIRING. NEW WALL AND DOOR JAMBS PROVIDED BY CONTRACTOR. 6.DEMO AND REMOVE EXISTING INTERIOR DOOR / DOOR FRAME / DOOR SILL / CASING UNLESS OTHERWISE NOTED (U.O.N) ON PLAN. 7.CUT OPENINGS NEATLY AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAINING OR ADJOINING CONSTRUCTION. 8. ANY FIRE EXTINGUISHERS TO BE REMOVED AND STORED FOR FUTURE USE. 9. AUTHORIZED CONSTRUCTION PERSONNEL ONLY WITHIN THE CONSTRUCTION AREA. 10. WORK TO BE DONE IN SUCH A MANNER AS TO HAVE MINIMUM DISRUPTION TO ONGOING CITY BUSINESS AND PARKING LOT. 11. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS. 12. USE EXPERIENCED WORKERS. 13. OCCUPANCY: IMMEDIATE AREAS OF WORK MAY BE OCCUPIED DURING DEMOLITION. THE PUBLIC MAY OCCUPY ADJACENT SPACES AND PARKING AREAS. 14. DEMOLISH DESIGNATED IMPROVEMENTS AS NECESSARY TO IMPLEMENT RENOVATION PLAN. 15. IMPLEMENT POLLUTION CONTROL DURING BUILDING DEMOLITION¸ INCLUDING NOISE CONTROL AFFECTING ONGOING CITY BUSINESS. 16. HAZARDOUS MATERIALS: IF HAZARDOUS MATERIALS ARE NOTED THEY WILL BE REMOVED UNDER SEPARATE CONTRACT. NOTIFY OWNER IF HAZARDOUS MATERIAL IS DISCOVERED TO BE PRESENT. 17. DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE, NOT SPECIFIED ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE. STORAGE OR SALE OF ITEMS IS PROHIBITED. 18. UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN AREAS TO BE DEMOLISHED. 19. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND BRACING AS REQUIRED. 20. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES, PARKING SPACES OR OTHER OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING OCCUPIED OR USED FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. 21. RESTORATION: RESTORE FINISHES OF PATCHED AREAS. EXISTING DEMISING WALL TO REMAIN EXISTING DEMISING WALL TO REMAIN EXISTING DEMISING WALL TO REMAIN 25'-2" EXISTING TO REMAIN61'-10"51'-1" EXISTING TO REMAIN4'-6" OPENING BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH ANGIE'S SUBS BUILD-OUT A1 NEW BUILD-OUT PLANSANGIE'S SUBS RENOVATION299 ATLANTIC BLVD.ATLANTIC BEACH, FL 32233F O R M S P A C E , I N C DATE ISSUED: SEPTEMBER 19, 2024 CONSULTANT: REVISIONS: SHEET TITLE SHEET NUMBER PERMIT SET ARCHITECT: 200 FIRST STREET SUITE 205 NEPTUNE BEACH, FLORIDA 32266 design@200firststreet.com 904-535-0270 ph 904-246-8402 fax JNOverby , LLC ARCHITECTURE ∙ INTERIOR DESIGN Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville, Florida 32550 904∙704∙8628 JNO@JNOVERBY.COM FL. AR-0017060 ∙ FL. ID-4621 . EXISTING HARDWARE ON EXIT DOORS TO REMAIN. 2. PROVIDE TACTILE EXIT SIGNAGE TO MEET NFPA 101 7.10.7.3 3. PROVIDE FIRE EXTINGUISHERS PER CODE TAGGED AND SERVICED BY A COMMERCIAL FIRE SAFETY DEALER. CONSTRUCTION TYPE: TYPE IIB SPRINKLED: NO FIRE DISTRICT: NO NO. OF REQUIRED EXITS: 2 WIDTH OF REQUIRED EXITS (PER TABLE 1005.4): 36" MIN. CLEAR WIDTH OF CORRIDOR: 44" TRAVEL DISTANCE LIMIT (PER 1030.3): 75 FT. DEAD END CORRIDOR LIMIT: 20 FT. WORK AREA: TOTAL AREA: 1,920 SQ FT. 36" REQUIRED EXIT WIDTH 36" PROVIDED EXIT WIDTH DRAWING SYMBOLS & LEGEND GENERAL NOTES LIFE SAFETY NOTES PARTITION DETAIL EXISTING DEMISING WALL TO REMAIN 36" REQUIRED 36" PROVIDED 36" REQUIRED 36" PROVIDEDFLORIDA BUILDING CODE 8TH EDITION (2023) NATIONAL ELECTRIC CODE 2020 - NFPA 70-2020 FLORIDA FIRE PREVENTION CODE 8TH EDITION LOCATION MAP PROJECT LOCATION 1.DO NOT SCALE DRAWINGS. USE ONLY DIMENSIONS SHOWN ON DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE BUILDER SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION. BUILDER SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT JOBSITE. 2.DIMENSIONS SHOWN ARE TO FACE OF DRYWALL OR CENTERLINE OF STRUCTURE UNLESS OTHERWISE NOTED. 3.LOCATE DOORS SO THAT DOOR CASING ABUTS WALL FINISH OF ADJACENT WALL UNLESS OTHERWISE NOTED. 4.BUILDER SHALL COORDINATE ALL SHELVING & STORAGE REQUIREMENTS WITH DESIGNER OR OWNER. 5.IN THE EVENT OF ANY DISCREPANCIES, IMMEDIATELY NOTIFY THE OWNER. DO NOT PROCEED WITH AFFECTED WORK UNTIL ALL SUCH ISSUES HAVE BEEN FULLY RESOLVED. 6.ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH ALL CODES, REGULATIONS, AND RESTRICTIONS HAVING JURISDICTION. EXISTING DEMISING WALL TO REMAIN LIFE SAFETY PLAN SCALE: 3/16" =1'-0" CONCEPT SKETCHES: CONCEPT SKETCHES PROVIDED FOR GENERAL DESIGN INTENT ONLY. NOT INTENDED FOR CONSTRUCTION REFERENCE OR TO DEPICT EXACT DETAILS OF PROJECT CONSTRUCTION. ALTERATION LEVEL: 2 (PER FBC EXISTING) OCCUPANCY CLASSIFICATION:A2: ASSEMBLY OCCUPANCY LOAD: DINING 356 SF / 15 =24 OCCUPANTS 589 SF / 15 =39 OCCUPANTS BAR SEATING 10 LF / 24"= 5 OCCUPANTS WAITING AREA 60 SF / 15 = 4 OCCUPANTS STORAGE 49 SF / 300 = 1 OCCUPANT TOILET ROOMS 87 SF/150 = 1 OCCUPANT KITCHEN 664 SF / 200= 3 OCCUPANTS TOTAL OCCUPANT LOAD = 77 OCCUPANTS SEATING COUNT: EXTERIOR = 8 SEATS DINING =12 SEATS REAR DINING = 20 SEATS BAR SEATING = 6 SEATS TOTAL SEATING PROVIDED = 46 SEATS TYPICAL PARTITION 5/8" GWB TO 6" ABOVE CEILING ON BOTH SIDES OF 3 5/8" 20 GAGE MTL. STUDS @ 1'-4" O.C. ATTACHED TO EXISTING CEILING EXTERIOR WALL 5/8" GWB TO 6" ABOVE CEILING ON 1" MTL. FURRING @ 1'-4" O.C. ATTACHED TO EXISTING CEILING 25'-2" EXISTING TO REMAIN61'-10"51'-1" EXISTING TO REMAIN4'-6" OPENING TOILET 102 TOILET 103 REAR DINING 104 2 COMP SINKVENTLESSOVENSANDWICH PREPHAND SINKUPRIGHTFREEZER 4'-0"22'-0" BENCH SEATING3'-5" SEATING: 20 BAR SEATING: 6 SEATING: 12 OUTSIDE SEATING: 8 4'-0"6'-0"18"MIN.6'-0"TRAVEL DISTANCE = 64'-2"TRAVEL DISTANCE = 3 6 ' - 8 "18"MIN.12"MIN.SANDWICH PREPTYPE 'K' F.E. TYPE '2A10BC' RECESSED F.E. DINING 100 KITCHEN 101 WALK-IN COOLER 5'X6'HANDSINKJANITOR 105 6'-0"HAND SINK SALAD PREPPREPTABLEPREPTABLEWRAPTABLECUTTABLE9"3'-0"3'-0"3'-0" TRASH3'-1"16'-0"3'-6"2'-0" SHUFFLE BOARD A1 NEW BUILD-OUT PLANSANGIE'S SUBS RENOVATION299 ATLANTIC BLVD.ATLANTIC BEACH, FL 32233F O R M S P A C E , I N C DATE ISSUED: SEPTEMBER 19, 2024 CONSULTANT: REVISIONS: SHEET TITLE SHEET NUMBER PERMIT SET ARCHITECT: 200 FIRST STREET SUITE 205 NEPTUNE BEACH, FLORIDA 32266 design@200firststreet.com 904-535-0270 ph 904-246-8402 fax JNOverby , LLC ARCHITECTURE ∙ INTERIOR DESIGN Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville, Florida 32550 904∙704∙8628 JNO@JNOVERBY.COM FL. AR-0017060 ∙ FL. ID-4621 NEW FLOOR PLAN SCALE: 3/16" =1'-0" FURNITURE PLAN SCALE: 3/16" =1'-0" NOTE: PERMITS FOR MEP WORK WILL BE PROVIDED BY MEP SUBCONTRACTORS UNDER SEPARATE COVER 25'-2" EXISTING TO REMAIN61'-10"51'-1" EXISTING TO REMAIN103A 102A 4'-6" OPENING TOILET 102 TOILET 103 REAR DINING 104 104A 100A 4'-4" P.O.S. STATIONS8'-0"9'-0" SCREEN WALL5'-0"7'-4"12'-0"9'-0" 5'-7" DRINK DISPENSING AREA 4'-0"25'-0"18"MIN.12"MIN.42" H. KNEE WALL16'-6"3'-5"18"MIN.12"MIN.2'-0"3'-7"7'-6"2'-6"4'-2"26'-9"9'-0" DINING 100 KITCHEN 1016'-0"2'-11"9'-1"MOP SINK JANITOR 105 105A 5'-8"1'-6"4'-0"1'-6"3'-112"3'-9" ALIGN W/ COLUMN 3'-10 1 2 "25'-2" EXISTING TO REMAIN61'-10"51'-1" EXISTING TO REMAIN103A 102A 4'-6" OPENING TOILET 102 TOILET 103 REAR DINING 104 104A 100A 2 COMP SINK4'-4"VENTLESSOVENSANDWICH PREPP.O.S. STATIONS8'-0"HAND SINKUPRIGHTFREEZER 4'-0"9'-0" SCREEN WALL5'-0"7'-4"22'-0" BENCH SEATING12'-0"9'-0" 5'-7" 3'-5" DRINK DISPENSING AREA SEATING: 20 BAR SEATING: 6 SEATING: 12 OUTSIDE SEATING: 8 4'-0"4'-0"6'-0"25'-0"18"MIN.12"MIN.42" H. KNEE WALL16'-6"6'-0"3'-5"18"MIN.12"MIN.2'-0"3'-7"7'-6"2'-6"4'-2"26'-9"SANDWICH PREP9'-0" DINING 100 KITCHEN 101 WALK-IN COOLER 5'X6'6'-0"2'-11"9'-1"HANDSINKMOP SINK JANITOR 105 105A 5'-8"6'-0"HAND SINK 1'-6"SALAD PREP4'-0"PREPTABLEPREPTABLE1'-6"WRAPTABLECUTTABLE3'-112"9"3'-9" 3'-0"3'-0"3'-0" TRASH ALIGN W/ COLUMN 3'-10 1 2 "3'-1"16'-0"3'-6"2'-0" SHUFFLE BOARD A2 NEW BUILD-OUT PLANSANGIE'S SUBS RENOVATION299 ATLANTIC BLVD.ATLANTIC BEACH, FL 32233F O R M S P A C E , I N C DATE ISSUED: SEPTEMBER 19, 2024 CONSULTANT: REVISIONS: SHEET TITLE SHEET NUMBER PERMIT SET ARCHITECT: 200 FIRST STREET SUITE 205 NEPTUNE BEACH, FLORIDA 32266 design@200firststreet.com 904-535-0270 ph 904-246-8402 fax JNOverby , LLC ARCHITECTURE ∙ INTERIOR DESIGN Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville, Florida 32550 904∙704∙8628 JNO@JNOVERBY.COM FL. AR-0017060 ∙ FL. ID-4621 REFECTED CEILING PLAN SCALE: 3/16" =1'-0" ELECTRICAL LAYOUT PLAN SCALE: 3/16" =1'-0" DUPLEX RECEPTACLE DATA/CAT'5E' OUTLET SWITCH GFI OUTLET COUNTERTOP HEIGHT EXHAUST FAN/LIGHT NUTONE QTXEN080FLT OR SIMILAR THREE-WAY SWITCH SURFACE MOUNTED EMERGENCY LIGHT ELECTRICAL LEGEND QUADPLEX RECEPTACLE REFLECTED CEILING PLAN NOTES 1.VERIFY ALL EXISTING CONDITIONS. 2.ADDITIONAL SPECIFICATION AND FIXTURE INFORMATION IS PROVIDED AND AVAILABLE ON OWNER SUPPLIED FIXTURE CUT SHEETS. REVIEW BEFORE INSTALLATION. 3.COORDINATE LIGHT FIXTURE LOCATIONS CONTRACTOR ANY DISCREPANCIES SHALL BE COMMUNICATED TO THE OWNER BEFORE CONSTRUCTION PROCEEDS FOR COORDINATION. 4.LIGHT FIXTURES SHALL BE LOCATED AS CLOSELY AS POSSIBLE TO LOCATIONS SHOWN ON THIS PLAN. FIXTURES SHALL ALIGN WITH OR CENTER ON EACH OTHER OR WITH ADJACENT ARCHITECTURAL. 5.COORDINATE LOCATIONS OF LIGHT FIXTURES WITH HVAC GRILLES SO THAT THEY ALIGN WITH OR ARE AT SYMMETRICAL WITH EACH OTHER WHERE THERE MAY BE CONFLICTS. 6. GRILLES & REGISTERS SHALL BE BLOCKED AS REQUIRED SO THAT THEY CAN ALIGN WITH LIGHT FIXTURES. 7.LIGHT FIXTURE & SWITCH LOCATIONS SHALL BE REVIEWED & APPROVED BY OWNER OR DESIGNER BEFORE INSTALLATION. 8.SWITCHES SHALL BE LOCATED ADJACENT TO BUT NOT INTERSECTING DOOR CASING OR TRIM. 9.GROUPED SWITCHES SHALL BE GANGED TIGHT TOGETHER & SHALL BE COVERED WITH A SINGLE PLATE DESIGNED FOR THAT PURPOSE. 10.SWITCHES SHALL TYPICALLY BE MOUNTED 48" AFF TO CENTER OF SWITCH. 11.SUPPORT ALL FIXTURES FROM STRUCTURE OF BUILDING. 12.VERIFY DEVICE & PLATE COLORS WITH OWNER OR DESIGNER. 13.VERIFY LIGHTING TYPE & SWITCHING. 14.ALL LIGHT BULBS SHALL BE COMPACT FLUORESCENT “WARM WHITE DELUXE” OR LED BULBS UNLESS OTHERWISE NOTED OR SPECIFIED ON SCHEDULE. NOTE: PERMITS FOR MEP WORK WILL BE PROVIDED BY MEP SUBCONTRACTORS UNDER SEPARATE COVER NOTE: PERMITS FOR MEP WORK WILL BE PROVIDED BY MEP SUBCONTRACTORS UNDER SEPARATE COVER TOILET 102 TOILET 103 REAR DINING 104 2 COMP SINKVENTLESSOVENSANDWICH PREPHAND SINKUPRIGHTFREEZER 4'-0" 3'-5"4'-0"6'-0"18"MIN.6'-0"P3 P3 P3 P1 P1P1 R1 R1 R1 R1 R1 R1 R1 R1 P5 T1 T1 T1 T1 T1 T1 T1 T1 T1 R1 EXHAUST FAN P2 R1 R1 T1 T1 T1 R1 R1 R1 R1 R1 R1 R1P2 EXISTING TRACK LIGHTING TO REMAIN S3 S3 S3 S3 S3 S3 P4 P4 P418"MIN.12"MIN.SANDWICH PREPP3 P3 P3 DINING 100 KITCHEN 101 WALK-IN COOLER 5'X6'HANDSINKJANITOR 105 6'-0"HAND SINK SALAD PREPPREPTABLEPREPTABLEWRAPTABLECUTTABLE9"3'-0"3'-0"3'-0" TRASH TOILET 102 TOILET 103 REAR DINING 104 2 COMP SINKVENTLESSOVENSANDWICH PREPHAND SINKUPRIGHTFREEZER 4'-0"22'-0" BENCH SEATING3'-5" SEATING: 20 BAR SEATING: 6 SEATING: 12 OUTSIDE SEATING: 8 4'-0"6'-0"18"MIN.6'-0"P3 P3 P3 P1 P1P1 R1 R1 R1 R1 R1 R1 R1 R1 P5 T1 T1 T1 T1 T1 T1 T1 T1 T1 R1 EXHAUST FAN P2 R1 R1 T1 T1 T1 R1 R1 R1 R1 R1 R1 R1P2 EXISTING TRACK LIGHTING TO REMAIN S3 S3 S3 S3 S3 S3 P4 P4 P418"MIN.12"MIN.SANDWICH PREPP3 P3 P3 DINING 100 KITCHEN 101 WALK-IN COOLER 5'X6'HANDSINKJANITOR 105 6'-0"HAND SINK SALAD PREPPREPTABLEPREPTABLEWRAPTABLECUTTABLE9"3'-0"3'-0"3'-0" TRASH3'-1"16'-0"3'-6"2'-0" SHUFFLE BOARD A3 INTERIOR DETAILSANGIE'S SUBS RENOVATION299 ATLANTIC BLVD.ATLANTIC BEACH, FL 32233F O R M S P A C E , I N C DATE ISSUED: SEPTEMBER 19, 2024 CONSULTANT: REVISIONS: SHEET TITLE SHEET NUMBER PERMIT SET ARCHITECT: 200 FIRST STREET SUITE 205 NEPTUNE BEACH, FLORIDA 32266 design@200firststreet.com 904-535-0270 ph 904-246-8402 fax JNOverby , LLC ARCHITECTURE ∙ INTERIOR DESIGN Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville, Florida 32550 904∙704∙8628 JNO@JNOVERBY.COM FL. AR-0017060 ∙ FL. ID-4621 TYPICAL A.D.A. REQUIREMENT DETAILS 2 COMP SINK18"MIN.18"MIN.12"MIN.HANDSINK INTERIOR ELEVATION 1/4" = 1'-0" A A3 T-1 RUNNING BOND PATTERN PENDANT LIGHT 18"X36" MIRROR INTERIOR ELEVATION 1/4" = 1'-0" B A3 GRAB BARS T.P. DISPENSER H.C. TOILET T-1 WALL TILE INTERIOR ELEVATION 1/4" = 1'-0" C A3 T-1 WALL TILE INTERIOR ELEVATION 1/4" = 1'-0" D A3 T-1 WALL TILE TOWEL DISPENSER/ TRASH ENLARGED PLAN 1/2" = 1'-0" 1 A3 RESTROOMS: ALL ELEMENTS OF ACCESSIBLE RESTROOMS SHALL COMPLY WITH A.D.A.A.G. SECTIONS 4.15, 4.16, 4.17, 4.18, 4.19 AND 4.22. SIDE ELEVATION MOUNTING HEIGHTS:MIRRORSTOWEL & SOAP DISPENSERS (TYP. FOR WALL VENDING) DRINKING FOUNTAINS FRONT ELEVATION WALL MOUNTED LAVATORY CLEAR FLOOR SPACE WALL MOUNTED LAVATORY PATH OF TRAVEL AND RAMPS: ALL WALKS, HALLS, CORRIDORS, AISLES, AND OTHER SPACES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH A.D.A.A.G.SECTION 4.3. SIGNAGE: ALL ACCESSIBLE SIGNAGE SHALL COMPLY WITH A.D.A.A.G. SECTION 4.30. 60" TURNING CLEARANCE SINGLE WHEELCHAIR MIN. CLEAR WIDTH DOORS: ALL ACCESSIBLE DOORS SHALL COMPLY WITH A.D.A.A.G. SECTION 4:13. PULL SIDE DOOR CLEARANCES PUSH SIDE DOOR CLEARANCES