808 AMBERJACK LN RES24-0044 BLOWER DOOR TESTIUES rounded in Excellence unty:Da/al Geotechnical Engineering.Construction Materials Testing &Inspection Building Code Compliance Occupational Health &Safety Environmental Building Envelope Duct TightnessBlower Door TestResultsForm ilder:T./.ostructin ad lofing Address:808 Anberjack Ln Lot: >mmunity:Atati Beach r Leakage Test Results Permit: Model: Prescriptive Method -Thebuilding or dweling unit shall be tested and ventied as having an air eakage rate of not exceeding 7 air changes per hour ata pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 &2. Preformance Method -The building or dweling unit shall be tested and venfied as having an air leakage rate of not exceeding the selected ACH50)value. X 60+26839 Buikiing Volume FAIL 207 CFM(50) 4.722 ACH(50) PASS Method forcakculatingbuiking volume: Retieved from architectural Plans Code software calculated Fiekd measured and calculated When ACH(50)is less than 3,Mechanical Ventilation installation must be veńfied by Buiding Department. Testing.Testing shall be conducted in accordance with ANSI/RESNETNCC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or (7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)X0).(9).or (i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Duct Leakage Test Results Prescriptive Method -To qualty as substantaly leakfree Qnmust be less than or equal to 0.04 if airhandler unit is installed.If air handler unit is not installed,Qn Total must be less an or equal to 0.03.This testing method meets the requitements inaccordance with Section R403.3.3 Performance Method -To qualify using this method,Qn must not be greater than the proposed duct specfied on Form R405-2017 or R406-2017. Square Footage: System 1 System 2 System 3 Sum of any additional systems Total of all systems Flow Ring:Pressure: Total Conditioned Square Footage cím25 cfm25 cím25 cfm25 cfm25 Total of all systems leakage Qn On PASS hereby cetty that above test resultsdemonstrate complance with energy code requirements in accordance with 2020 (7th Edition)Fbnda Buiding-Energy Conservation Code. Date of Test:|SignatureofTester:Ah InspectorLicenseNumber.BF3HN FAIL