Loading...
426 Aquatic Dr - RESO24-0121 PATIO ALTERATION - ARCH DWGAPPLICABLE CODE: - FLORIDA BUILDING CODE 2023 ,8TH EDITION - FLORIDA PLUMBING CODE 2023,8TH EDITION - FLORIDA MECHANICAL CODE 2023,8TH EDITION - NATIONAL ELECTRICAL CODE 2018 - FLORIDA FIRE PREVENTION CODE 2023 CODE SUMMARY: - APPLICABLE CODE FBC 2023, 8TH EDITION - CONSTRUCTION TYPE B. - UNHEATED ALTERATION AREA: 182 SQFT - OCCUPANCY TYPE: RESIDENTIAL - GROUP R3 REV. #DATE CODES & SCHEDULES 0 SCALE DRAWING BY DATE DWG # AS SHOWN Sulaiman Sanam A-01 DESIGN BY Sulaiman Sanam Samer Attallah DRAWING INDEX CONTENTSDWG A-01 CODES, SUMMARY & SCHEDULES & EXISTING /NEW PLAN & NEW ELEVATION A-02 S01 SAMER G .A TTAL L A HPROF E SSION A L E N G INEERFL O R I D ALICENSE No. 84156 STATE OF A-01 SEVEN GATES DESIGN LLC. 2916 UNIVERSITY BLVD W. Suite 200 JACKSONVILLE, FL 32217 11-21-2024 11-21-2024 SCOPE OF WORK ALTERATION CLASSIFICATION: LEVEL 2 - ALTER EXISTING 182 SQFT PATIO AREA TO CREATE NEW ENCLOSED UNHEATED SPACE. - REPLACE EXISTING SCREEN PANELS WITH NEW GLASS WINDOWS. - BLOCK OUT ONE SIDE WALL WITH WOOD FRAMING FILL-IN WALL W/ 1/12" GYPSUM BOARD INSIDE & OSB SHEATHING W/ SIDING FINISH OUTER SIDE. - ENSURE ALL STRUCTURAL COMPONENTS COMPLY WITH LOCAL BUILDING CODES FOR SAFETY AND STABILITY. - MAKE FINISHING WORK (PAINTING, FLOORING) WALL FRAMING PLAN & WALL SECTION WINDOWS & DOORS INSTALLATION DETAILS THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY SAMER ATTALLAH, P.E. ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FAC 61G15-23.004 WALL LEGEND DESCRIPTIONTYPE 426 AQUATIC PATIOALTERATION426 AQUATIC DRIVE,ATLANTIC BEACH , FL 3223317'-4"17'-9" 4'-5" 4'-4" 4'-4" 3' 10" 4'-9"4'-9" ±00 ±00 6" EXISTING HOUSEALUMINUM POST -0'-6" A - A - 17'-4"17'-8" ±00 ±00 6" EXISG PLAN -0'-6" 9'-9"3' 4'-1" 4'-2" 4'-2" 2'-8"7'-1"2'-8"4" 7'-9" 5'-10" 3'-9" 7'-9" 5'-10" 3'-9" 9'-9" T O P +7'- 5" F F L ±0-0" GROUND LEVEL -0'-6" WINDOW SILL: 2'-0" A.F.F. SINGLE OR DOUBLE HUNG GLASS WINDOWS PANELS, USE SAFETY TEMPERED GLASS PANES. ALUM OR VINYL W/ GLASSWD13'-0"X4'-0"NEW 3040 sill24 WD1 T O P +7'- 5" F F L ±0-0" 3040 sill24 WD1 3040 sill24 WD1 NEW WINDOW SCHEDULE NEW DOOR SCHEDULE MATERIAL / DESCRIPTIONSIZEDOOR.NO HARDWARE REMARKS 3-0"X8'-0"NDO1 MATERIALSIZEWINDOW NO HARDWARE & DESCRIPTION REMARKSSTATUS DOOR KNOB LEVER W/ KEY LOCKALUMiNUM /VINYL GLASS EXISTING EXTERIOR WALL NEW FILL-IN WALL 2"X4" WOOD STUD @ 24" MAX O.C. W/ 1/2" GYPSUM BOARD INSIDE & OSB PANELS OUT SIDE W/ SIDING FINISH EXISTING ALUMINUM POST VICINITY PLAN N.T.S. NDO1 DO1 DO2 SIDING PLANKS PAINTED FINISH SIDE ELEVATION SCALE: 1/4"=1' FRONT ELEVATION SCALE: 1/4"=1' EXISTING INSULATED ROOFING PANEL NEW FILL IN WALL PAINTING FINISH EXISG PARAPET PAINTING FINISH EXISG PLAN EXISG ROOF EXISTING FLOOR PLAN SCALE: 1/4"=1' NEW FLOOR PLAN SCALE: 1/4"=1' EXISTING STORAGE EXISG STORGE A - A - EXISTING INSULATED ROOFING PANEL SIDING PLANKS PAINTED FINISH NEW FILL IN WALL PAINTING FINISH CUT WEATHER BARRIER @ 45°ANGLE MODIFIED "l" CUT IN WEATHER BARRIER LINE OF WINDOW OPENING APPROVED WEATHER BARRIER OVER SHEATHING OVER WD STUD WALL 7" 7" 135° STEP 1 STEP 2 TEMPORARILY FOLD-UP & SECURE WEATHER BARRIER (OR TUCK FLAP UNDER) @ HEAD FOLD WEATHER BARRIER IN AT JAMBS AND SILL 6" TYP. MECHANICALLY FASTEN FANNED EDGE (CAP, NAILS, STAPLES) IF REQUIRED BY FLASHING MANUFACTURER INSTALL 9" WIDE SELF-ADHERING FLEXIBLE MEMBRANE FLASHING @ SILL EXTEND FLASHING UP JAMBS 6" MIN. STEP 3 STEP 4 APPLY 3/8" NOM. CONTINUOUS BEAD OF SEALANT AT JAMBS & HEAD OR APPLY TO BACK OF WINDOW NAILING FLANGE IN LINE w/ PRE-PUNCHED HOLES OR SLOTS STEP 5 INSTALL WINDOW PLUMB, LEVEL & SQUARE PER MANUFACTURERS WRITTEN INSTRUCTIONS 5" STEP 6 INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERNAILING FLANGE @ JAMBS EXTEND MEMBRANE FLASHING MIN. 1" BELOW SILL FLEXIBLE FLASHING 1" MIN." STEP 7 INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERNAILING FLANGE @ HEAD 1" MIN."EXTEND SELF-ADHERING MEMBRANE FLASHING 1" MIN. BEYOND JAMB FLASHING NOTE: 1. WINDOW INSTALLATION & FLASHING DETAILS ARE CONSISTENT WITH ASTM2112 METHOD A-1 EXCEPT SELF-ADHERING MEMBRANE FLASHINGS ARE USED. 2. IT IS THE INSTALLATION CONTRACTORS RESPONSIBILITY TO VERIFY THE COMPATIBILITY OF ALL PRODUCTS INCLUDING WEATHER BARRIER, SEALANT & SELF-ADHERING FLASHING MATERIALS USED DURING CONSTRUCTION. 3. INSTALL ALL MATERIALS PER MANUFACTURERS WRITTEN SPECIFICATIONS. WARNING: SEALANT/FLASHINGS MAY REACT ADVERSELY IF NOT COMPATIBLE. STEP 8 STEP 9 INTERIOR VIEW FOLD WEATHER BARRIER DOWN & TAPE DIAGONAL CUT & ACROSS HEAD OF WINDOW SEAL WINDOW FRAME TO INSIDE OF R.O. WITH SEALANT AT SILL AND A MINIMUM 12" UP BOTH JAMS TO FORM A BACK DAM. SEAL BALANCE OF FRAME WITH SEALANT OR LOW-EXPANDING FOAM (PROVIDE BACKER ROD WHERE REQUIRED)12" MIN. w/SEALANTAPPROVED WEATHER BARRIER OVER WD SHEATHING FOLD WEATHER BARRIER IN AND AROUND JAMBS CUT WEATHER BARRIER INSTALL DOOR PLUMB, LEVEL & SQUARE PER MANUFACTURER WRITTEN INSTRUCTIONS SET THRESHOLD IN BED OF SEALANT APPLY SEALANT AT CORNERS & FRONT EDGE OF THRESHOLD STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 NOTE: AT UNPROTECTED DOORS, BOTTOM 1/4th OF JAMBS SHALL BE COMPOSITE, P.T. OR OTHER DECAY RESISTANT MATERIAL INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERLAPPING DOOR FRAME 1/4" INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERLAPPING DOOR FRAME 1/4" EXTEND SELF-ADHERING MEMBRANE FLASHING 1" MIN. BEYOND JAMB FLASHING SEE DOOR DETAILS FOR FINISH/TRIM DETAILS 4" 1/4" 1/4" 1/4" 1" MIN. WINDOW FLASHING INSTALLATION DETAILS N.T.S. DOOR FLASHING INSTALLATION DETAILS N.T.S. LINE OF DOOR OPENING REV. #DATE WINDOW & DOOR INSTALLATION METHODS 0 SCALE DRAWING BY DATE DWG # AS SHOWN Sulaiman Sanam A-02 DESIGN BY Sulaiman Sanam Samer AttallahSAMERG.A TTAL L A HPROF E SSION A L E N G INEERFL O R I D ALICENSE No. 84156 STATE OF A-02 SEVEN GATES DESIGN LLC. 2916 UNIVERSITY BLVD W. Suite 200 JACKSONVILLE, FL 32217 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY SAMER ATTALLAH, P.E. ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. FAC 61G15-23.004 11-21-2024 11-21-2024426 AQUATIC PATIOALTERATION426 AQUATIC DRIVE,ATLANTIC BEACH , FL 32233