426 Aquatic Dr - RESO24-0121 PATIO ALTERATION - ARCH DWGAPPLICABLE CODE:
- FLORIDA BUILDING CODE 2023 ,8TH EDITION
- FLORIDA PLUMBING CODE 2023,8TH EDITION
- FLORIDA MECHANICAL CODE 2023,8TH EDITION
- NATIONAL ELECTRICAL CODE 2018
- FLORIDA FIRE PREVENTION CODE 2023
CODE SUMMARY:
- APPLICABLE CODE FBC 2023, 8TH EDITION
- CONSTRUCTION TYPE B.
- UNHEATED ALTERATION AREA: 182 SQFT
- OCCUPANCY TYPE: RESIDENTIAL - GROUP R3
REV. #DATE
CODES &
SCHEDULES
0
SCALE
DRAWING
BY
DATE
DWG #
AS SHOWN
Sulaiman Sanam
A-01
DESIGN BY Sulaiman Sanam
Samer Attallah
DRAWING INDEX
CONTENTSDWG
A-01 CODES, SUMMARY & SCHEDULES &
EXISTING /NEW PLAN & NEW ELEVATION
A-02
S01
SAMER G .A TTAL
L
A
HPROF
E
SSION A L E N G INEERFL O R I D ALICENSE
No. 84156
STATE OF
A-01
SEVEN GATES DESIGN LLC.
2916 UNIVERSITY BLVD W. Suite 200
JACKSONVILLE, FL 32217
11-21-2024
11-21-2024
SCOPE OF WORK
ALTERATION CLASSIFICATION: LEVEL 2
- ALTER EXISTING 182 SQFT PATIO AREA TO CREATE
NEW ENCLOSED UNHEATED SPACE.
- REPLACE EXISTING SCREEN PANELS WITH NEW
GLASS WINDOWS.
- BLOCK OUT ONE SIDE WALL WITH WOOD FRAMING
FILL-IN WALL W/ 1/12" GYPSUM BOARD INSIDE & OSB
SHEATHING W/ SIDING FINISH OUTER SIDE.
- ENSURE ALL STRUCTURAL COMPONENTS COMPLY
WITH LOCAL BUILDING CODES FOR SAFETY AND
STABILITY.
- MAKE FINISHING WORK (PAINTING, FLOORING)
WALL FRAMING PLAN & WALL SECTION
WINDOWS & DOORS INSTALLATION
DETAILS
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY SAMER ATTALLAH, P.E.
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
FAC 61G15-23.004
WALL LEGEND
DESCRIPTIONTYPE 426 AQUATIC PATIOALTERATION426 AQUATIC DRIVE,ATLANTIC BEACH , FL 3223317'-4"17'-9"
4'-5"
4'-4"
4'-4"
3'
10"
4'-9"4'-9"
±00 ±00
6" EXISTING HOUSEALUMINUM POST
-0'-6"
A
-
A
-
17'-4"17'-8"
±00 ±00
6"
EXISG PLAN
-0'-6"
9'-9"3'
4'-1"
4'-2"
4'-2"
2'-8"7'-1"2'-8"4"
7'-9"
5'-10"
3'-9"
7'-9"
5'-10"
3'-9"
9'-9"
T O P
+7'- 5"
F F L
±0-0"
GROUND LEVEL
-0'-6"
WINDOW SILL: 2'-0" A.F.F.
SINGLE OR DOUBLE HUNG GLASS WINDOWS
PANELS, USE SAFETY TEMPERED GLASS PANES.
ALUM OR VINYL W/
GLASSWD13'-0"X4'-0"NEW
3040
sill24
WD1
T O P
+7'- 5"
F F L
±0-0"
3040
sill24
WD1
3040
sill24
WD1
NEW WINDOW SCHEDULE
NEW DOOR SCHEDULE
MATERIAL / DESCRIPTIONSIZEDOOR.NO HARDWARE REMARKS
3-0"X8'-0"NDO1
MATERIALSIZEWINDOW
NO HARDWARE & DESCRIPTION REMARKSSTATUS
DOOR KNOB LEVER W/ KEY LOCKALUMiNUM /VINYL GLASS
EXISTING EXTERIOR WALL
NEW FILL-IN WALL 2"X4" WOOD
STUD @ 24" MAX O.C. W/ 1/2"
GYPSUM BOARD INSIDE & OSB
PANELS OUT SIDE W/ SIDING FINISH
EXISTING ALUMINUM POST
VICINITY PLAN
N.T.S.
NDO1 DO1
DO2
SIDING PLANKS
PAINTED FINISH
SIDE ELEVATION
SCALE: 1/4"=1'
FRONT ELEVATION
SCALE: 1/4"=1'
EXISTING INSULATED
ROOFING PANEL
NEW FILL IN WALL
PAINTING FINISH
EXISG PARAPET
PAINTING FINISH
EXISG PLAN
EXISG ROOF
EXISTING FLOOR PLAN
SCALE: 1/4"=1'
NEW FLOOR PLAN
SCALE: 1/4"=1'
EXISTING
STORAGE EXISG STORGE
A
-
A
-
EXISTING INSULATED
ROOFING PANEL
SIDING PLANKS
PAINTED FINISH
NEW FILL IN WALL
PAINTING FINISH
CUT WEATHER
BARRIER @
45°ANGLE
MODIFIED "l" CUT IN
WEATHER BARRIER
LINE OF WINDOW OPENING
APPROVED WEATHER
BARRIER OVER SHEATHING
OVER WD STUD WALL
7"
7"
135°
STEP 1 STEP 2
TEMPORARILY FOLD-UP &
SECURE WEATHER
BARRIER (OR TUCK FLAP
UNDER) @ HEAD
FOLD WEATHER BARRIER IN
AT JAMBS AND SILL
6" TYP.
MECHANICALLY FASTEN
FANNED EDGE (CAP, NAILS,
STAPLES) IF REQUIRED BY
FLASHING MANUFACTURER
INSTALL 9" WIDE
SELF-ADHERING FLEXIBLE
MEMBRANE FLASHING @
SILL
EXTEND FLASHING UP
JAMBS 6" MIN.
STEP 3
STEP 4
APPLY 3/8" NOM.
CONTINUOUS BEAD OF
SEALANT AT JAMBS & HEAD
OR APPLY TO BACK OF
WINDOW NAILING FLANGE IN
LINE w/ PRE-PUNCHED
HOLES OR SLOTS
STEP 5
INSTALL WINDOW PLUMB,
LEVEL & SQUARE PER
MANUFACTURERS WRITTEN
INSTRUCTIONS
5"
STEP 6
INSTALL 4" WIDE
SELF-ADHERING
MEMBRANE FLASHING
OVERNAILING FLANGE @
JAMBS
EXTEND MEMBRANE
FLASHING MIN. 1" BELOW
SILL FLEXIBLE FLASHING
1"
MIN."
STEP 7
INSTALL 4" WIDE
SELF-ADHERING
MEMBRANE FLASHING
OVERNAILING FLANGE @
HEAD 1"
MIN."EXTEND SELF-ADHERING
MEMBRANE FLASHING 1"
MIN. BEYOND JAMB
FLASHING
NOTE:
1. WINDOW INSTALLATION &
FLASHING DETAILS ARE
CONSISTENT WITH ASTM2112
METHOD A-1 EXCEPT
SELF-ADHERING MEMBRANE
FLASHINGS ARE USED.
2. IT IS THE INSTALLATION
CONTRACTORS
RESPONSIBILITY TO VERIFY
THE COMPATIBILITY OF ALL
PRODUCTS INCLUDING
WEATHER BARRIER, SEALANT
& SELF-ADHERING FLASHING
MATERIALS USED DURING
CONSTRUCTION.
3. INSTALL ALL MATERIALS PER
MANUFACTURERS WRITTEN
SPECIFICATIONS.
WARNING:
SEALANT/FLASHINGS MAY
REACT ADVERSELY IF NOT
COMPATIBLE.
STEP 8 STEP 9
INTERIOR VIEW
FOLD WEATHER BARRIER
DOWN & TAPE DIAGONAL
CUT & ACROSS HEAD OF
WINDOW
SEAL WINDOW FRAME TO
INSIDE OF R.O. WITH
SEALANT AT SILL AND A
MINIMUM 12" UP BOTH
JAMS TO FORM A BACK
DAM. SEAL BALANCE OF
FRAME WITH SEALANT OR
LOW-EXPANDING FOAM
(PROVIDE BACKER ROD
WHERE REQUIRED)12" MIN. w/SEALANTAPPROVED WEATHER
BARRIER OVER WD
SHEATHING
FOLD WEATHER
BARRIER IN AND
AROUND JAMBS
CUT WEATHER
BARRIER
INSTALL DOOR PLUMB,
LEVEL & SQUARE PER
MANUFACTURER WRITTEN
INSTRUCTIONS
SET THRESHOLD IN
BED OF SEALANT
APPLY SEALANT AT
CORNERS & FRONT EDGE
OF THRESHOLD
STEP 1 STEP 2 STEP 3
STEP 4 STEP 5
NOTE: AT UNPROTECTED DOORS, BOTTOM
1/4th OF JAMBS SHALL BE COMPOSITE, P.T.
OR OTHER DECAY RESISTANT MATERIAL
INSTALL 4" WIDE
SELF-ADHERING MEMBRANE
FLASHING OVERLAPPING
DOOR FRAME 1/4"
INSTALL 4" WIDE
SELF-ADHERING MEMBRANE
FLASHING OVERLAPPING
DOOR FRAME 1/4"
EXTEND SELF-ADHERING
MEMBRANE FLASHING 1" MIN.
BEYOND JAMB FLASHING
SEE DOOR DETAILS FOR
FINISH/TRIM DETAILS
4"
1/4"
1/4"
1/4"
1"
MIN.
WINDOW FLASHING INSTALLATION DETAILS
N.T.S.
DOOR FLASHING INSTALLATION DETAILS
N.T.S.
LINE OF DOOR OPENING
REV. #DATE
WINDOW & DOOR
INSTALLATION
METHODS
0
SCALE
DRAWING
BY
DATE
DWG #
AS SHOWN
Sulaiman Sanam
A-02
DESIGN BY Sulaiman Sanam
Samer AttallahSAMERG.A TTAL
L
A
HPROF
E
SSION A L E N G INEERFL O R I D ALICENSE
No. 84156
STATE OF
A-02
SEVEN GATES DESIGN LLC.
2916 UNIVERSITY BLVD W. Suite 200
JACKSONVILLE, FL 32217
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY SAMER ATTALLAH, P.E.
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT
ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES.
FAC 61G15-23.004
11-21-2024