1775 Selva Marina Drive TREE24-0064 02.05.2025 NOIPERMIT #:TREE24-0064
ADDRESS:1775 Selva Marina Drive
APPLICANT: Henry Staley
PHONE: 904-610-9679
EMAIL: hankstaley@aol.com
CATEGORY DBH 8" - 13.9"# OF TREES INCHES OWED DBH 14" - 29.9"# OF TREES INCHES OWED DBH 30"+# OF TREES INCHES OWED TOTAL INCHES
REMOVED PRESERVATION CREDIT TOTAL OWED
OAK 91 87
Oak 8 1 4 and/or
16 1 16
20 1 20 13,050.00$
23 1 23
24 1 24
MARITIME SPECIES
and/or
-$
PALM 10 5
Cabbage 10 1 5 and/or
750.00$
OTHER
Pine and/or
-$
101 92
and/or
13,800.00$
CATEGORY INCHES # OF TREES STAFF NOTES PROPOSED- PLANT PROPOSED- PAY CATEGORY INCHES # OF TREES STAFF NOTES FINAL- PLANT FINAL- PAY
OAK OAK
MARITIME SPECIES 96" MARITIME SPECIES
Live oak 4 12 double credit
PALM PALM
OTHER OTHER
TOTALS 96"
PROPOSED MITIGATION FINAL MITIGATION
DEVELOPED LOT
MITIGATION RATIOS: (inches removed : inches replaced)
DBH 8" -13.9"= 1: 0.5
DBH 14" - 29.9" = 1: 1
TREES REMOVED
DBH 30"+ = 1:2
Status in accordance with the City of Altantic Beach code of ordinances in effect at the time of application submittal.
APPROVDED
DENIED
TPO ADMINISTRATOR DATE
ADDITIONAL INFORMATION:
•The current tree fund rate is $150.00 per inch.
•One shade tree shall be planted or preserved within the required front yard of every lot.
PLANTING REQUIRMENTS
•Oaks must be replaced with oaks and have a 4" caliper and 12' tall at time of planting.
•Maritime Species must be replaced with Maritime Species.
•Mininum 2" caliper for non oaks and 10' tall at time of planting.
•Palms may replace plams.Mininum 8ft clear trunk height at time of planting.
•Maritime species receive double credit when replacing non-Maritime species.
Zoning Approved
01/31/2025
DEVELOPED LOT
TREE24-0064
X PRESERVING TREE 1/31/2025
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
AUGUST 9, 2024
PERMIT SETSTALEY RESIDENCE1775 SELVA MARINA DRIVEATLANTIC BEACH, FL 32233JNOverby, LLC
ARCHITECTURE ∙ INTERIOR DESIGN
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville, Florida 32550
904∙704∙8628
JNO@JNOVERBY.COM
FL. AR-0017060 ∙ FL. ID-4621
T1
ARCHITECTURAL
SITE
PLAN
LOT COVERAGE:
TOTAL LOT 21,357 S.F.
EXISTING HOUSE 1,998 S.F.
NEW ADDITION 1,018 S.F.
REAR PATIO 465 S.F.
PAVER PATIO 945 S.F.
NEW DRIVE WAY EXTENSION 800 S.F.
DRIVEWAY/WALK 1,575 S.F.
TOTAL IMPERVIOUS 6,801 S.F. (32%)
NEW
ADDITION
15'-0"12'-0"16'-0"16'-0"32'-
6
"33'-6"16'-0"
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
AUGUST 9, 2024
PERMIT SETSTALEY RESIDENCE1775 SELVA MARINA DRIVEATLANTIC BEACH, FL 32233JNOverby, LLC
ARCHITECTURE ∙ INTERIOR DESIGN
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville, Florida 32550
904∙704∙8628
JNO@JNOVERBY.COM
FL. AR-0017060 ∙ FL. ID-4621
A1
ADDITION
FLOOR
PLAN
GENERAL NOTES:
1. ALL WORK TO BE DONE IN ACCORDANCE TO THE MOST RECENT EDITION OF FLORIDA
BUILDING CODES AND ALL OTHER APPLICABLE NATIONAL, STATE AND LOCAL CODES AND
ORDINANCES.
2. VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN FIELD PRIOR TO CONSTRUCTION.
VERIFY LAYOUT WITH REFERENCE TO EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE
COMMUNICATED IN WRITING TO THE ARCHITECT BEFORE CONSTRUCTION PROCEEDS.
3. IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL WORK IS IN STRICT ACCORDANCE
WITH THE LATEST EDITION OF ALL APPLICABLE CONSTRUCTION STANDARDS.
4. ALL DIMENSIONS ARE TO FACE OF DRYWALL OR CENTERLINE OF STRUCTURE UNLESS
OTHERWISE NOTED.
5. FLOOR PENETRATIONS TO BE WATERPROOFED.
6. ALL INTERIOR WALLS TO BE WOOD STUDS UNLESS OTHERWISE NOTED.
7. WHERE G.C. IS TO PROVIDE TYPE 'X' GYP. BD. FOR A RATED ASSEMBLY, THE TYPE 'X' GYP. BD.
IS REQUIRED TO GO BENEATH THE SHEATHING AND FINISHES.
8. INTERIOR DOORS ARE TO BE 5" OFF PERPENDICULAR WALLS UNLESS OTHERWISE NOTED.
9. IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL MANUFACTURED ARTICLES,
MATERIAL AND EQUIPMENT ARE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED,
ADJUSTED, OPERATED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS, UNLESS
HEREIN SPECIFIED TO THE CONTRARY. BUILDER SHALL FOLLOW ALL INSTRUCTIONS TO SUSTAIN
AND PRESERVE ALL EXPRESSED OR IMPLIED WARRANTIES AND GUARANTEES.
10. IT IS THE BUILDER'S RESPONSIBILITY TO CHECK ALL PLAN DIMENSIONS & DETAILS FOR
OVERALL ACCURACY APPROPRIATE TO THE SITE & FINAL SELECTION OF MASONRY, FLOOR
JOISTS, LUMBER, STRUCTURAL MEMBERS, VENEER, ROOFING, ETC.
11. SUBSTITUTES FOR SPECIFIC MATERIALS & MANUFACTURERS SHOWN ON THESE PLANS MAY
BE OFFERED, BUT MUST BE APPROVED IN WRITING BY THE ARCHITECT AND OWNER PRIOR TO
PROCURING OR INSTALLING.
12. RESPONSIBILITY OF THE GC INCLUDES, BUT IS NOT LIMITED TO, PROPER INSTALLATION OF
MATERIALS, NAILING, GLUING, CAULKING, INSULATING, FLASHING, ROOFING, WEATHERPROOFING
& ANY OTHER SMALL ITEMS OR DETAILS NOT NECESSARILY INDICATED ON THE PLANS.
13. THESE PLANS ARE NOT INTENDED TO BE COMPLETE IN ALL DETAILS OF WEATHERPROOFING.
USE OF A VARIETY OF DIFFERENT MATERIALS CAN CHANGE DETAILS. ADDITIONALLY, VARYING
CODES & REGULATIONS, FOUNDATION REQUIREMENTS, ELECTRICAL AND MECHANICAL PLANS
CAN CHANGE THESE DETAILS.
14. FURNITURE TO BE COORDINATED, INSTALLED AND SCHEDULED BY G.C. AND THE OWNER
15. ALL KITCHEN APPLIANCES INSTALLED TO BE COORDINATED AND SCHEDULED BY G.C.
16. G.C. TO SCHEDULE & COORDINATE THE INSTALLATION OF OWNER PROVIDED ITEMS,
INCLUDING, BUT NOT LIMITED TO, FURNITURE & AUDIO/VIDEO SYSTEMS.
BUILDING CODE SUMMARY
CODE ENFORCEMENT JURISDICTION:
CITY OF ATLANTIC BEACH
OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-3)
BUILDING CODE:
CONSTRUCTION TYPE: TYPE V-B (WOOD FRAME)
SPRINKLED: NO
FIRE DISTRICT: NO
PROVIDE INSULATION PER CODE
R-38 IN CEILING, R-13 IN WALLS
ALTERATION LEVEL: 2
Florida Building Code 8th Edition (2023) Building
Florida Building Code 8th Edition (2023) Residential
Florida Building Code 8th Edition (2023) Plumbing
National Electric Code 2020 - NFPA 70-2020
Florida Building Code 8th Edition (2023)
Energy Conservation
Florida Building Code 8th Edition (2023) Mechanical
Florida Fire Prevention Code 8th Edition
WORK AREA-
NEW ADDITION 883 S.F. GUEST SUITE
W/ 444 S.F. WORK SHOP/STORAGE
EXISTING RESIDENCE
TO REMAIN
11'-2"
EXTENDED
DRIVEWAY
4'-10"
16'-0"14'-10"16'-0"32'-
6
"
3/0
13'-
0
"
BEDROOM
(2)
3
'
-
0
"
x
5
'
-
0
"
E
G
R
E
S
S
W
I
N
D
O
W
S
KIN
G
B
E
D
9'-0
"
DW
REF
5'-0"10'-0"5'-0"
KITCHENETTE
3'-0"x5'-0" WINDOW18'-112"CLOSET
LIVING
6/0
3/0 8'-6"3'-6"BREEZEWAY
8"16'-0"
4'-10"
3'-8"7'-6"7'-6"7'-0" MEDIA WALL10'-0"14'-10"3'-0"33'-6"(2)
2
-
6
"
x
5
'
-
0
"
E
G
R
E
S
S
W
I
N
D
O
W
S
7'-0
"
M
E
D
I
A
W
A
L
L 7'-412"3'-0
"(3)2'-6"x5'-0" WINDOWS7'-8"2'-0"x3'-0"
WINDOW
4'-2"4'-0"6'-0"WALK-IN
SHOWER
A
A2
1/4" = 1'-0"
FLOOR PLAN
B
A2D
A2
C
A2
PANTRY
CAB
2'-6"3'-0"3'-0"
W/D
STACK
3/0
1 2 3 4 5 6 7 8
16 15 14 13 12 11
10
EXTERIOR
STAIRS
17
9
6"3'-10"6"12'-0"7'-6"TOILET
ROOM
3/0
4'-4"3/0
3/0
6'-0
"
7'-1
1
"
3/0
4'-3
"
4'-6"
BATH
WORK SHOP
16'-0"
3/0
1 2 3 4 5 6 7 8
16 15 14 13 12 11
10
EXTERIOR
STAIRS3'-6"1/4" = 1'-0"
SECOND FLOOR PLAN
3'-6"7'-10"4'-4"7'-8"27'-9"17
2'-6"x3'-6"
WINDOW
93'-6"4'-4"
2'-6"x2'-6"
WINDOW
STORAGE
2'-0"x2'-6" WINDOWS2'-0"10'-0" DORMER2'-0"x2'-6" WINDOWS2'-0"x2'-6" WINDOWS2'-0"10'-0" DORMER2'-0"x2'-6" WINDOWSSLOPED
CEILING
SLOPED
CEILING
SLOPED
CEILING2'-0"4'-9"
4'-9"
SLOPED
CEILING 2'-0"4'-9"
4'-9"
3/012'-0"4'-3"5'-6"9'-0"2'-6"3'-9"2'-0"10'-0" DORMER2'-0"10'-0" DORMER3'-9"9'-0"- 30" D. WORKBENCH4'-3" STORAGE2'-0"SHELFSLOPED
CEILING
SLOPED
CEILING
9'-0"- 30" D. WORKBENCH4'-3" STORAGE2'-0"SHELF
A2
EXTERIOR
ELEVATIONS
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
AUGUST 9, 2024
PERMIT SETSTALEY RESIDENCE1775 SELVA MARINA DRIVEATLANTIC BEACH, FL 32233JNOverby, LLC
ARCHITECTURE ∙ INTERIOR DESIGN
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville, Florida 32550
904∙704∙8628
JNO@JNOVERBY.COM
FL. AR-0017060 ∙ FL. ID-4621
SCALE:
FRONT ELEVATION
1/4" = 1'-0"
A
A2 9'-0" CEILIING21'-7" OVERALL HEIGHTBREEZEWAY
TO MAIN HOUSE
10'-6" - 17 EXTERIOR STEPS8'-0" LOFT1'-6"2.5
12
ROOF
SLOPE
8
12
ROOF
SLOPE
15'-0" BEARING8'-0" BREEZEWAY3'-6"4'-6"2'-9"SCALE:
SIDE ELEVATION
1/4" = 1'-0"
D
A29'-0" CEILIING8'-0" CEILING1'-6"21'-7" OVERALL HEIGHTBREEZEWAY
TO MAIN HOUSE
EXISTING
MAIN HOUSE
8'-0" BEARINGSCALE:
REAR ELEVATION
1/4" = 1'-0"
C
A2 9'-0" CEILIING1'-6"21'-7" OVERALL HEIGHTSCALE:
SIDE ELEVATION
1/4" = 1'-0"
B
A2 9'-0" CEILIING8'-0" CEILING1'-6"21'-7" OVERALL HEIGHTBREEZEWAY
TO MAIN HOUSE
EXISTING
MAIN HOUSE
8'-0" BEARING10'-0" DORMER 10'-0" DORMER
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
AUGUST 9, 2024
PERMIT SETSTALEY RESIDENCE1775 SELVA MARINA DRIVEATLANTIC BEACH, FL 32233JNOverby, LLC
ARCHITECTURE ∙ INTERIOR DESIGN
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville, Florida 32550
904∙704∙8628
JNO@JNOVERBY.COM
FL. AR-0017060 ∙ FL. ID-4621
A1A
34' OPTION
FLOOR
PLAN
ELECTRICAL LAYOUT PLAN NOTES:
1. VERIFY ALL EXISTING CONDITIONS.
2. COORDINATE LIGHT FIXTURE LOCATIONS CONTRACTOR ANY
DISCREPANCIES SHALL BE COMMUNICATED TO THE ARCHITECT BEFORE
CONSTRUCTION PROCEEDS FOR COORDINATION.
3. LIGHT FIXTURES SHALL BE LOCATED AS CLOSELY AS POSSIBLE TO
LOCATIONS SHOWN ON THIS PLAN.
4. FIXTURES SHALL ALIGN WITH OR CENTER ON EACH OTHER OR WITH
ADJACENT ARCHITECTURAL ELEMENTS.
5. COORDINATE LOCATION OF LIGHT FIXTURES WITH HVAC GRILLS SO
THAT THEY ALIGN WITH OR ARE SYMMETRICAL WITH EACH OTHER
WHERE THERE MAY BE CONFLICTS.
6. GRILLS & REGISTERS SHALL BE BLOCKED AS REQUIRED SO THAT
THEY CAN ALIGN WITH LIGHT FIXTURES.
7. LIGHT FIXTURE & SWITCH LOCATIONS SHALL BE REVIEWED &
APPROVED BY OWNER OR DESIGNER BEFORE INSTALLATION OF SHEET
ROCK OR OTHER WALL & CEILING FINISHES.
8. SWITCHES SHALL BE LOCATED ADJACENT TO, BUT NOT
INTERSECTING DOOR CASING OR TRIM.
9. GROUPED SWITCHES SHALL BE GANGED TIGHT TOGETHER & SHALL
BE COVERED WITH A SINGLE PLATE DESIGNED FOR THAT PURPOSE.
10. SWITCHES SHALL TYPICALLY BE MOUNTED 48" A.F.F. TO CENTER OF
THE SWITCH.
11. SUPPORT ALL FIXTURES FROM STRUCTURE OF BUILDING. REFER
TO STRUCTURAL SHEETS FOR SPECIFIC DETAILS AS REQUIRED FOR
SPECIALTY FIXTURES.
12. VERIFY DEVICE & PLATE COLORS WITH OWNER OR DESIGNER.
13. VERIFY LIGHTING TYPE & SWITCHING.
14. FLUORESCENT LAMPS SHALL BE "WARM WHITE DELUXE" UNLESS
OTHERWISE NOTED OR SPECIFIED ON THE SCHEDULE.
15. ALL LIGHT BULBS SHALL BE COMPACT FLUORESCENT OR LED
BULBS UNLESS OTHERWISE NOTED.
16. COORDINATE THERMOSTAT AND DOORBELL LOCATIONS WITH OWNER.
TV
ELECTRICAL LEGEND
CABLE
GFI RECEPTACLE
EXTERIOR/GFI RECEPTACLE
3-WAY SWITCH
SWITCH
DUPLEX OUTLET
NOTES:
1. TELEPHONE OUTLETS TO BE 'CAT 5E' WIRE.
2. SMOKE DETECTION PER FIRE CODE.
3. SERVICE PANEL AND ELECTRIC METER
LOCATION TO BE DETERMINED W/ INPUT FROM THE
OWNER AND LOCAL UTILITY COMPANY.
4. ALL RECEPTACLE TO HAVE ARC-FAULT CIRCUIT
INTERRUPTERS PER ARTICLE 210-12.
5. HVAC DISCONNECT TO BE PROVIDED BY
MECHANICAL SUBCONTRACTOR.
6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE
WITH LATEST EDITION OF NEC AND FBC.
7. 100% OF ALL INTERIOR AND EXTERIOR
PERMANENT LIGHT FIXTURES TO USE CFL/LED
LAMPS.
COUNTERTOP HEIGHTCH
SD SMOKE DETECTOR
CM
CARBON
MONOXIDE
DETECTOR
220 OUTLET
WORK SHOP
EXTERIOR
STAIRS
1/4" = 1'-0"
ELECTRICAL LAYOUT PLAN
STORAGE
4EXISTING RESIDENCE
TO REMAIN
EXTENDED
DRIVEWAY
BEDROOM
KIN
G
B
E
D
KITCHENETTE
CLOSET
LIVING
BREEZEWAY1/4" = 1'-0"
ELECTRICAL LAYOUT PLAN
EXTERIOR
STAIRS
BATH
4' A.F.FTVCH
CH
CH
CH CHCH4' A.F.FTV4433
33
333433433433U.C.
LIGHTING
3SD
SD
CM
A4
ROOF
PLAN
AND
DETAIL
NOTE:
DO NOT SCALE DRAWINGS.
IF PRINTED ON 11"X17"
MEDIA, DRAWING SCALE
IS HALF-SIZED.
DATE ISSUED:
AUGUST 9, 2024
PERMIT SETSTALEY RESIDENCE1775 SELVA MARINA DRIVEATLANTIC BEACH, FL 32233JNOverby, LLC
ARCHITECTURE ∙ INTERIOR DESIGN
Julianne N. Overby, R.A.
2452 Pullian Street
Jacksonville, Florida 32550
904∙704∙8628
JNO@JNOVERBY.COM
FL. AR-0017060 ∙ FL. ID-4621
ROOF VENTS/PENETRATIONS:
ALL RIDGE VENTS AND PENETRATIONS TO BE INSTALLED PER THE
MANUFACTURER'S RECOMMENDATIONS-
APPLY ROOFNG CEMENT OR SELF ADHERING FLASHING OVER VENT FLANGE AT
THE HEAD
INSTALL SHINGLE OVER THE VENT FLANGE HEAD
ROOF PLAN NOTES:
1. DO NOT SCALE DRAWINGS.
2. IF DIMENSIONS ARE IN QUESTION, THE ROOFER SHALL BE RESPONSIBLE FOR OBTAINING
CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION
3. BUILDER SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT JOBSITE.
4. SEE FLOOR PLAN FOR BUILDING DIMENSIONS.
5. ALL ROOFING AND ROOFING DETAILS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
INDUSTRY STANDARDS AND MANUFACTURER'S INSTRUCTIONS.
6. ROOFING SUBCONTRACTOR SHALL HAVE APPROPRIATE LICENSE(S) AS REQUIRED IN
JURISDICTION OF CONSTRUCTION.
7. NO WORK SHALL CONFLICT WITH THE MANUFACTURER'S GUARANTEE OR WARRANTY.
8. WRITTEN WARRANTY SHALL BE PROVIDED TO OWNER AND INCLUDED IN THE CLOSE OUT
DOCUMENTS PROVIDED BY GC.
9. PROVIDE FLASHING AS PER DETAILS OR AS PER SMACNA IF NO DETAILS ARE SHOWN WHERE
ROOF PITCH CHANGES OR WHERE ROOFING INTERSECTS WITH VERTICAL SURFACES.
10. THE INSTALLATION SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL ROOFING
WORK .
11. ALL EXHAUST FAN, VENT, FLUE & STACK OPENINGS ARE TO BE CUT & SEALED BY BUILDER.
12. ROOF VENT TERMINALS SHALL BE 12' AWAY FROM AND 2' ABOVE ANY AIR INTAKE, DOOR OR
WINDOW, 18" AWAY FROM ANY VERTICAL WALL EXTENDING ABOVE ROOF VENT, AND NOT BELOW
ANY ROOF EAVE, OR AS REQUIRED BY LOCAL CODES.
NOTE: THESE DETAILS USED FOR DOORS & WINDOW.
ALL FLASHING TO MEET FBC R903.2.1, R905.2.8. & R703.8 AND INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.SCALE:
TYP. WALL SECTION
3/4" = 1'-0"
1
A4
NOTE:
ALL STRUCTURAL SIZES TO BE VERIFIED WITH LICENSED
STRUCTURAL ENGINEER OF RECORD FOR THIS PROJECT.
THESE WALL SECTIONS SHOWN FOR DESIGN INTENT.9'-0" CEILINGASPHALT SHINGLE ROOF
TO MATCH EXISTING
ON 15# ROOFING
FELT OVER 7/16"
EXT. SHEATHING
12
8
R-38 INSULATION
4'-6" BEARING1/2" GYP. BOARD
OVER FRAMING W/
R-13 INSULATION
6" MIN.4" CONCRETE SLAB OVER
VAPOR BARRIER
SEE STRUCTURAL DRAWING
1/2" EXP. JOINT
GROUT FILLED 8" CMU STEM WALL
CONT. CONCRETE FOOTING
SEE STRUCTURAL DRAWINGS
1/2" GYP. BOARD
2x WOOD FRAME SPECIFIED BY
STRUCTURAL ENGINEER WITH 7/16"
OSB OR ZIP SHEATHING AND HOUSE
WRAP APPLIED TO OSB PER
MANUFACTURER'S
RECOMMENDATIONS WITH
SIDING EXTERIOR FINISH
METAL DRIP
OVER FASCIA
OVER 2X6 SUB
FASCIA MATCH
EXISTING TRIM
FLOOR JOIST
PER STRUCTURAL
R-38 INSULATION
1/2" GYP. BOARD
OVER FRAMING W/
R-13 INSULATION
1/2" GYP. BOARD
1"7 5/8"11"
SCALE:
STAIR DETAIL
1/4" = 1'-0"
2
A41'-6"12
2.5
1/4" = 1'-0"
ROOF PLAN8'-0"3'-6
"1'-6"1'-6"3'-10"1'-6
"1'-6"1'-6
"1'-6"8:12 ROOF
SLOPE
8:12 ROOF
SLOPE6:12 ROOFSLOPE6:12 ROOFSLOPE2.5:
1
2
R
O
O
F
SL
O
P
E
7'-10"1'-6"1'-6"
2.5:12 ROOF
SLOPE
2.5:12 ROOF
SLOPE
4:12 ROOF
SLOPE
ATTACHED TO EXISTINGRESIDENCE4'-10"
2.5:12 ROOF
SLOPE
2.5:12 ROOF
SLOPE 6"6"1'-6"10'-0"6"6"1'-6"10'-0"2.5:12 ROOF
SLOPE
2.5:12 ROOF
SLOPE
6"6"1'-6"10'-0"6"6"1'-6"10'-0"2'-9"2'-9"1'-6"1'-6"
8:12 ROOF
SLOPE
8:12 ROOF
SLOPE
8:12 ROOF
SLOPE
8:12 ROOF
SLOPE
EXTERIOR
STAIRS
BELOW
6:12 ROOF
SLOPE