No preview available
 /
     
725 Atlantic Blvd ROW25-0007 PermitOWNER:ADDRESS:CITY:STATE:ZIP: ATLANTIC-PENMAN LLC 500 S 3RD ST JACKSONVILLE BEACH FL 32250 COMPANY:ADDRESS:CITY:STATE:ZIP: FIBER TECHNOLOGIES SOLUTIONS 1515 CR 210 W Suite 300 St. Augustine FL 32095 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171363 0000 ROYAL PALMS UNIT 02A JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 725 ATLANTIC BLVD RIGHT OF WAY COMMERCIAL RIGHT OF WAY COMCAST - BORES FOR UNDERGROUND COAX $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878. State Law requires calling Sunshine 811 to have ALL public utilities located BEFORE beginning the work. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 3Issued Date: 2/26/2025 PERMIT NUMBER ROW25-0007 ISSUED: 2/26/2025 EXPIRES: 5/27/2025 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 4 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. Full site to be grassed. 6 PUBLIC WORKS UTILITY ROAD CUT INFORMATIONAL Notes: Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans.\r\r\r\r\r\r\r\r\r\r 7 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 8 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 9 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 10 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 11 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 12 PUBLIC WORKS DEBRIS INFORMATIONAL Notes: Roadway must be kept free of debris, mud, dirt, etc. during and after project by Contractor. All holes that have been dug and any property that has been disturbed must have barriers and flags placed during project by Contractor. 2 of 3Issued Date: 2/26/2025 PERMIT NUMBER ROW25-0007 ISSUED: 2/26/2025 EXPIRES: 5/27/2025 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 13 PUBLIC WORKS PROPERTY LINE - WATER RETENTION INFORMATIONAL Notes: Water retention must have a minimum of 10 feet offset from structure unless a letter is provided by an Engineer stating that the structure will have no impact from the water retention. Must have a minimum of 2 feet offset of water retention from front and rear property lines and a minimum of 5 feet offset of water retention from side property lines. 14 PUBLIC WORKS OTHER PUBLIC WORKS CONDITION INFORMATIONAL Notes: 3 of 3Issued Date: 2/26/2025 PERMIT NUMBER ROW25-0007 ISSUED: 2/26/2025 EXPIRES: 5/27/2025 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ROW25-0007Public Utilities Approved02/18/2025Public Works Approved02/25/2025 ROW25-0007Public Works Approved02/25/2025 BEGINENDCOMCAST PERMIT REQUEST FOR725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233JOB SITE:725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233ESCAMBIACOUNTYSANTA ROSACOUNTYOKALOOSACOUNTYWALTONCOUNTYHOLMESCOUNTYWASHINGTONCOUNTYBAY COUNTYCALHOUNCOUNTYGULFCOUNTYFRANKLINCOUNTYLIBERTYCOUNTYWAKULLACOUNTYGADSDENCOUNTYJEFFERSONCOUNTYMADISONCOUNTYTAYLORCOUNTYHAMILTONCOUNTYSUWANNEECOUNTYCOLUMBIACOUNTYUNIONCOUNTYLAFAYETTECOUNTYDIXIECOUNTYGILCHRISTCOUNTYALACHUA COUNTYLEVY COUNTYMARION COUNTYSUMTERCOUNTYVOLUSIACOUNTYLAKECOUNTYSEMINOLECOUNTYORANGE COUNTYHERNANDOCOUNTYCITRUSCOUNTYPASCO COUNTYPOLK COUNTYOSCEOLACOUNTYPINELLASCOUNTYMANATEECOUNTYHARDEECOUNTYDESOTOCOUNTYSARASOTACOUNTYCHARLOTTECOUNTYGLADES COUNTYHIGHLANDSCOUNTYHENDRYCOUNTYLEE COUNTYCOLLIER COUNTYBROWARDCOUNTYMIAMI-DADECOUNTYMONROECOUNTYPALM BEACHCOUNTYMARTINCOUNTYSAINT LUCIECOUNTYOKEECHOBEECOUNTYINDIAN RIVERCOUNTYBREVARDCOUNTYHILLSBOROUGHCOUNTYBAKERCOUNTYBRADFORDCOUNTYPUTNAMCOUNTYFLAGLERCOUNTYLEONCOUNTYNASSAUCOUNTYST JOHNSCOUNTYJACKSONCOUNTYCLAYCOUNTYDUVALCOUNTYPROJECT TOTALSVICINITY MAP725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233JOB NUMBER:PROPOSED UG CATV/FIBERTOTAL FOOTAGETOTAL PROPOSED BORE PITSTOTAL PROPOSED VAULTSTOTAL PROPOSED BORESTOTAL PROPOSED PEDSPROPOSED AERIAL CABLE FOOTAGEPROPOSED AERIAL STRANDJB0002101807501'0'0'501'4310R/WPublic Utilities Approved02/18/2025Public Works Approved02/25/2025 R/WALL UTILITIES LOCATED BYVISUAL INSPECTION, TO BEVERIFIED BY LOCATESEOT REPRESENTS EDGE OFTRAVEL NOT TRUE EDGE OFPAVEMENTEOP REPRESENTS THE TRUEEDGE OF PAVEMENTEOD REPRESENTS THE EDGEOF DIRTHAND DIG TRENCHES 36" DEEPACROSS DIRT ROADNOTESALL PROPOSED CONSTRUCTION WILL BE PERTHE CITY OF ATLANTIC BEACH SPECIFICATIONS AS WELL AS ALL NECESSARY SAFETY CODES.ALL PROPOSED CATV WILL BE WITHIN CITY OFATLANTIC BEACH RIGHT-OF-WAY.ALL PROPOSED UNDERGROUND CATV WILL BEBURIED A MINIMUM OF 36" DEEP EXCEPT ROAD BORES60" DEEP AND DRIVEWAY BORES AT 60" DEEP.ALL PROPOSED UNDERGROUND CATV ROAD BORESWILL USE CITY APPROVED DIRECTIONAL BOREMACHINE, AS WELL AS COUNTY APPROVED CONDUIT.ALL PROPOSED CATV ROAD BORES WILL EXTEND AMINIMUM OF 48" BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED CATV DRIVEWAY BORES WILL EXTENDA MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.ALL PROPOSED BORES WILL BE IN A (4'X4'X4') PITAND WILL USE 1(2") HDPE CONDUIT AT 60" DEPTHUSING A 5 1/4" DRILL HEAD.ALL PROPOSED AERIAL WILL BE .700" DIAMETER ANDWILL BE LASHED TO .250" STEEL STRAND CABLEUSING .125" STANDARD GALVANIZED LASHING WIRE.ALL PROPOSED AERIAL CATV CROSSING ROADWAYSWILL HAVE MINIMUM MID-SPAN HEIGHT OF 18'-0"ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYSWILL HAVE MINIMUM MID-SPAN HEIGHT OF 16'-0"LOCATES WILL BE REQUIRED IN ALL PROPOSEDUNDERGROUND AREAS AT LEAST 48 HRS PRIOR TOCONSTRUCTION.NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BEMADE PRIOR TO CONSTRUCTION.ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAYWILL BE RESTORED TO ORIGINAL OR BETTERCONDITION BY GRADING AND RE-SODDING. SOD ALLAREAS DISTURBED BY CONSTRUCTION WITHBERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BEREPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OFWORK COMPLETION."WORK OPERATIONS ARE TO BE MINDFUL NOT TODAMAGE THE PAVER SIDEWALK WHEN POSITIONINGEQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKSWILL BE REPAIRED OR REPLACED BY THECONTRACTOR.CONSTRUCTION NOTESIN ORDER TO REDUCE THE DISRUPTION ANDCOST OF UTILITY DAMAGES OCCURRING INTHE RIGHT-OF-WAY AND EASEMENTS. THEPERMITTEE SHALL PREVENT DAMAGES TOEXISTING UTILITIES CAUSED BY THE WORKTHROUGH FIELD VERIFICATION OF THELOCATION OF THE EXISTING UTILITIES INCASE OF OPEN EXCAVATION. VERIFICATIONMAY BE PERFORMED DURING THEPERMITTEES WORK. IN THE CASE OFDIRECTIONAL DRILLING, VERIFICATION SHALLTAKE PLACE PRIOR TO MOBILIZATION OF THEDRILLING EQUIPMENT.THE PERMITTEE SHALL VERIFY THE LOCATIONOF THE EXISTING UTILITIES AS NEEDED TOAVOID CONTACT WITH DETECTIONEQUIPMENT OR OTHER ACCEPTABLE MEANS,SUCH METHODS MAY INCLUDE BUT SHALLNOT BE LIMITED TO-"SOFT DIG"-EQUIPMENTAND GROUND PENETRATION RADAR (GPR).THE EXCAVATOR SHALL BE HELD LIABLE FORDAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRUCTURE AND THE EXISTINGFACILITIES OF THE OTHER UTILITYCOMPANIESCOMMUNICATIONPublic Works Approved02/25/2025 CLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/WD/W64'20'20'24'56' 15'24'64'18'22'24'64'18'22'24'60' 26'24'10'66'14'28'24'700711385365355345340709335325315725275243355AVECUNA RDSAILFISH DR ESAILFISH DR ESAILFISH DR ESAILFISH DR ECAVALLA RD5' SW5' SWCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM 9' FROM BOCCOMM 11' FROM BOCCOMM 8' FROM BOCSEWER 10' FROM BOC5' SWCOMM CROSSINGSEWER CROSSINGCOMM 7' FROM BOCCOMM 5' FROM BOCWATER 3' FROM BOCCOMM 7' FROM BOCCOMM 5' FROM BOCWATER 3' FROM BOCCOMM 9' FROM BOCCOMM 16' FROM BOCCOMM 14' FROM BOCGAS 7' FROM BOCDB DBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM5' SWVEND PROJECTPROPOSED VAULTCATV/FIBER FACILITIESSTA: 05+01GPS COORDINATESN 30.326349W -81.40719817'94'01+0002+0003+0004+000 5 + 0 0 CROSS SECTION-ACROSS SECTION-BRUN LINE 9' FROM BOCIN 1(2") HDPE CONDUITRUN LINE 9' FROM BOCIN 1(2") HDPE CONDUITCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMBEGIN PROJECTEXISTING CABINETCATV/FIBER FACILITIESSTA: 00+00GPS COORDINATESN 30.327726W -81.407370ROAD BORE-BROAD BORE-A9'9'11'11'4'PROPOSED BOREPIT-01(4'X4'X4')CATV/FIBER FACILITIESSTA: 00+94GPS COORDINATESN 30.327473W -81.40733273'170'164'PROPOSED BOREPIT-02(4'X4'X4')CATV/FIBER FACILITIESSTA: 01+67GPS COORDINATESN 30.327276W -81.407297PROPOSED BOREPIT-03(4'X4'X4')CATV/FIBER FACILITIESSTA: 03+37GPS COORDINATESN 30.326795W -81.407225725 ATLANTIC BLVD, ATLANTIC BEACH, FL 3223301 OF 02725 ATLANTIC BLVD, ATLANTIC BEACH, FL 3223302 OF 02RUN LINE 11' FROM BOCIN 1(2") HDPE CONDUITNSEWR/WPublic Works Approved02/25/2025 CLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WD/WD/WD/WD/WD/WD/WD/WD/WD/W64'20'20'24'56'15'24'64'18'22'24'700711385365355345340335355AVECUNA RDSAILFISH DR ESAILFISH DR ECOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM 9' FROM BOCCOMM 11' FROM BOCCOMM 8' FROM BOCSEWER 10' FROM BOCCOMM CROSSINGSEWER CROSSINGCOMM 7' FROM BOCCOMM 5' FROM BOCWATER 3' FROM BOCDBDBDBDBDBDBDBDBDBDBDBDBDB17'94'01+0002+00CROSS SECTION-ARUN LINE 9' FROM BOCIN 1(2") HDPE CONDUITCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMBEGIN PROJECTEXISTING CABINETCATV/FIBER FACILITIESSTA: 00+00GPS COORDINATESN 30.327726W -81.407370ROAD BORE-A9'11'11'PROPOSED BOREPIT-01(4'X4'X4')CATV/FIBER FACILITIESSTA: 00+94GPS COORDINATESN 30.327473W -81.40733273'170'PROPOSED BOREPIT-02(4'X4'X4')CATV/FIBER FACILITIESSTA: 01+67GPS COORDINATESN 30.327276W -81.407297725 ATLANTIC BLVD, ATLANTIC BEACH, FL 3223301 OF 02RUN LINE 11' FROM BOCIN 1(2") HDPE CONDUITNSEWR/WPublic Works Approved02/25/2025 CLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLBOCBOCBOCBOCBOCBOCBOCBOCBOCBOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WD/WD/WD/WD/WD/W64'18'22'24'60'26'24'10'66'14'28'24'709325315725275243SAILFISH DR ESAILFISH DR ECAVALLA RD5' SW5' SWCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM5' SWCOMM 7' FROM BOCCOMM 5' FROM BOCWATER 3' FROM BOCCOMM 9' FROM BOCCOMM 16' FROM BOCCOMM 14' FROM BOCGAS 7' FROM BOCDBDBDBDBDBDBDBDBDBDBDBDBCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMMCOMM5' SWVEND PROJECTPROPOSED VAULTCATV/FIBER FACILITIESSTA: 05+01GPS COORDINATESN 30.326349W -81.40719803+0004+000 5 + 0 0 CROSS SECTION-BRUN LINE 9' FROM BOCIN 1(2") HDPE CONDUITCOMMCOMMCOMMCOMMCOMMROAD BORE-B9'4'164'PROPOSED BOREPIT-03(4'X4'X4')CATV/FIBER FACILITIESSTA: 03+37GPS COORDINATESN 30.326795W -81.407225725 ATLANTIC BLVD, ATLANTIC BEACH, FL 3223302 OF 02NSEWR/WPublic Works Approved02/25/2025 64'32'32'20'20'12'12'BOC BOC CL R/W ROW R/W ROW CL0''60"48"36"24"12"0''60"48"36"24"12"72"72"PROPOSED RUN LINE 11' FROM BOC 11'COMM 9' FROM BOC 5' SW9'R/W725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233CROSS SECTION DETAIL-AFOR SAILFISH DR ELOOKING NORTHWESTPublic Works Approved02/25/2025 66'40'26'28'14'12'12'BOC BOC CL R/W ROW R/W ROW CL0''60"48"36"24"12"0''60"48"36"24"12"72"72"PROPOSED RUN LINE 9' FROM BOC 9'GAS 7' FROM BOC 5' SW7'14'16'COMM 14' FROM BOCCOMM 16' FROM BOC 725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233CROSS SECTION DETAIL-BFOR SAILFISH DR ELOOKING NORTHWESTR/WPublic Works Approved02/25/2025 0''60"48"36"24"12"72"0''60"48"36"24"12"72"56'27'29'17'12'12'15'60''BOC BOC 73'ENTRYPROPOSED BOREPIT-01(4'X4'X4')RECEIVEPROPOSED BOREPIT-02(4'X4'X4')1 (2") HDPE CONDUIT W/ 5 1/4" DRILL HEADCLCL R/W R/W R/W R/WR/W725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233ROAD BORE DETAIL-AFOR VECUNA RDLOOKING SOUTHEASTPublic Works Approved02/25/2025 0''60"48"36"24"12"72"0''60"48"36"24"12"72"60'22'38'26'12'12'10'60''BOC BOC 164'ENTRYPROPOSED BOREPIT-03(4'X4'X4')RECEIVEPROPOSED VAULT1 (2") HDPE CONDUIT W/ 5 1/4" DRILL HEADCLCL R/W R/W R/W R/W VR/W725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233ROAD BORE DETAIL-BFOR CAVALLA RDLOOKING SOUTHEASTPublic Works Approved02/25/2025 0''60"48"36"24"12"72"0''60"48"36"24"12"72"VARIESDRIVEWAYENTRYBORERECEIVEBOREHDPE CONDUIT W/ 5 1/4" DRILL HEAD725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233DRIVEWAY BORE DETAIL60" DEPTH1 (2")R/WPublic Works Approved02/25/2025 R/WTHE FOLLOWING STANDARD PLANSARE IN ACCORDANCE WITH THEFLORIDA DEPARTMENT OF TRANSPORTATION2025-2026 102-602 & 102-625 INDEX AND APPLY TO725 ATLANTIC BLVD, ATLANTIC BEACH, FL 32233xSTANDARD PLANS INDEX NO 102-602 (TWO-LANE ROADWAY, WORK ON SHOULDER)xSTANDARD PLANS INDEX NO 102-625 (TEMPORARY ROADWAY CLOSURE)Public Works Approved02/25/2025 LASTREVISION11/01/21REVISION DESCRIPTION:FY 2025-26STANDARD PLANSTWO-LANE ROADWAY, WORK ON SHOULDERINDEX 102-602SHEET 12 OF 13NOTESThis Index applies to Two-Lane, Two-Wayand Multilane Roadways, including Mediansof divided roadways, with work on theshoulder.L = Taper LengthX = Work Zone Sign SpacingB = Buffer LengthSee Index 102-600 for "L", "X", "B", andchannelizing device spacing values.Where work activities are between 2' and15' from the edge of traveled way, theEngineer may omit signs and channelizingdevices for work operations 60 minutesor less.When four or more work vehicles enter thethrough traffic lanes in a one hour period(excluding establishing and terminating thework area), use a flagger or lane closureto accommodate work vehicle ingress andegress.For work less than 2' from the traveled wayand work zone speed is greater than 45 MPH,use a lane closure.The "Speeding Fines Doubled When WorkersPresent" signs (MOT-13-06) and "End RoadWork" Signs (G20-2) along with theassociated work zone sign spacingdistances may be omitted when thework operation is in place for 24hours or less.Temporary pavement markings may beomitted when the work operation is inplace for 3 days or less.Omit "Shoulder Closed" signs (W21-5a) alongwith associated work zone sign spacingdistances for work on the median.When there is no paved shoulder, the"Worker" sign (W21-1) may be used insteadof the "Shoulder Closed" sign (W21-5a).1.2.3.4.5.6.7.8.9.Work AreaChannelizing Device (See Index 102-600)Work Zone SignLane Identification and Direction of TrafficSYMBOLS:TWO-LANE ROADWAYG 20-2(See Note 6)ENDROAD WORKROADWORKAHEADW20-1FROADWORKAHEADW20-1FRIGHTSHOULDERCLOSEDW21-5aENDROAD WORKG 20-2(See Note 6)SHOULDER WORK BETWEEN 2' AND 15' FROM THE TRAVELLED WAYXXL/3XXSAILFISH DR E25 MPHPublic Works Approved02/25/2025 REVISION DESCRIPTION:FY 2025-26STANDARD PLANSSHEET 13 OF 13INDEX 102-625LASTREVISION11/01/20TEMPORARY ROADWAY CLOSUREROADWORKAHEADW20-1FBEPREPAREDTO STOPW3-4FLAGGERAHEAD W20-7A(See Note 5)FLAGGERAHEAD W20-7A(See Note 5)ROADWORKAHEADW20-1FBEPREPAREDTO STOPW3-4MedianMedianXXXBXXXBWork AreaWork Zone SignLane Identification and Direction of TrafficSYMBOLS:TCOTraffic Control Officer(MUTILANE ROADWAY SHOWN,TWO-LANE ROADWAY SIMILAR)NOTES:1.This index applies to two-lane, two-way and multilane roadways,except limitedaccess facilities, win temporary daytime roadway closures of 5 minutes or less.2.B = Buffer Login X = Work Zone Sign Distance See Index 102-600 for "B" and "x" values.3.For Two-Lane Roadways, a Flagger may substitute the traffic control officer with approval of the engineer.4.Traffic volume or complexly of the roadway may dictate additional signs, devices or traffic control officers.5.Optionally, use FLAGGER AHEAD sign with symbol (W20-7) instead of FLAGGER AHEAD sign with text (W20-7A).6.Dual Signs are required for divided roadways only.CAVALLA RD20 MPHVECUNA RD20 MPHPublic Works Approved02/25/2025