No preview available
 /
     
2219 ALICIA LN RES25-0069 Permit Form with ConditionsFinal Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION OWNER:ADDRESS:CITY:STATE:ZIP: ZIRAKPARVAR M E 2219 ALICIA LN ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: PELLA WINDOWS DOORS 4306 Shader Road Ste 100 Orlando FL 32828 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169519 0765 TIFFANY BY THE SEA JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 2219 ALICIA LN RESIDENTIAL WINDOWS/DOORS 2 DOORS $30998.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING, WINDOW, AND DOOR INSPECTIONS, AND SHOULD BE SCHEDULED FOR THE FIRST DAY OF WORK. 2 PUBLIC WORKS NOTICE OF COMMENCEMENT INFORMATIONAL Notes: No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/12/2025 PERMIT NUMBER RES25-0069 ISSUED: 3/12/2025 EXPIRES: 9/8/2025 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $205.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 TOTAL: $315.19 2 of 2Issued Date: 3/12/2025 PERMIT NUMBER RES25-0069 ISSUED: 3/12/2025 EXPIRES: 9/8/2025 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $315.19 RES25-0069 Address: 2219 ALICIA LN APN: 169519 0765 $315.19 BUILDING $205.00 BUILDING PERMIT 455-0000-322-1000 0 $205.00 BUILDING PLAN REVIEW $102.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 STATE SURCHARGES $7.69 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 TOTAL FEES PAID BY RECEIPT: R29972 $315.19 Printed: Wednesday, March 12, 2025 8:45 AM Date Paid: Wednesday, March 12, 2025 Paid By: PELLA WINDOWS DOORS Pay Method: CREDIT CARD 10266103310 1 of 1 Cashier: TG Cash Register Receipt City of Atlantic Beach Receipt Number R29972 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL12459-R11 Application Type Affirmation Code Version 2023 Application Status Approved Comments Archived Product Manufacturer Pella Corporation Address/Phone/Email 102 Main St. Pella, IA 50219 (641) 621-6096 pellaproductapproval@pella.com Authorized Signature Joe Hayden Sandi Robinson pellaproductapproval@pella.com Technical Representative Joseph Hayden Address/Phone/Email 102 Main Street Pella, IA 50219 (641) 621-6096 jahayden@pella.com Quality Assurance Representative Pat Bortscheller Address/Phone/Email 102 Main Street Pella, IA 50219 (641) 621-1000 PJBortscheller@pella.com Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturer Association Validated By T.E. Lunn, PE, LLC Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard)Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-11 2011 ASTM E1886-05 2005 ASTM E1886-13a 2013 ASTM E1996-12 2012 ASTM E1996-14 2014 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Approved Certification Agency FL12459_R11_Equiv_2016-01 Rev 2 Tech Bulletin E1996 and E1886 Equivalency.pdf I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A Product Approval Method Method 1 Option A Date Submitted 07/19/2023 Date Validated 07/19/2023 Date Pending FBC Approval Date Approved 07/23/2023 Summary of Products FL #Model, Number or Name Description 12459.1 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door Companion Fixed Window O – Type 1 (48.788" x 95.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Glass & glazing shall be as specified in the attached glazing detail “A”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_O Traditional 48.788x95.5 Hallmark AAMA_ASTM_TAS CCLs.pdf Quality Assurance Contract Expiration Date 11/10/2026 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing Detail A.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.2 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (95.25" x 95.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Glass & glazing shall be as specified in the attached glazing detail “A”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 95.25x95.5 Hallmark AAMA_ASTM_TAS CCLs.pdf Quality Assurance Contract Expiration Date 12/29/2026 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing Detail A.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.3 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (71.25" x 95.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Glass & glazing shall be as specified in the attached glazing detail “A”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 71.25x95.5 Hallmark AAMA_ASTM_TAS CCLs.pdf Quality Assurance Contract Expiration Date 12/14/2026 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing Detail A.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.4 Pella/Architect Series and Pella/Architect Series Reserve Clad Traditional Sliding Door Companion Fixed Window O – Type 1 (60.788" x 119.5") Sliding Impact Glass Doors Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-50 Other: Glass & glazing shall be as specified in the attached glazing detail “B”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_O Traditional 60.788x119.5 Hallmark AAMA ASTM TAAS CCLs.pdf Quality Assurance Contract Expiration Date 10/03/2027 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing detail B.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.5 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (119.25" x 119.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +35/-45 Other: Glass & glazing shall be as specified in the attached glazing detail “B”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 119.25x119.5 Hallmark AAMA ASTM TAAS CCLs.pdf Quality Assurance Contract Expiration Date 10/09/2027 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing detail B.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.6 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door XO or OX – Type 2 (71.25" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Cont. 71.25x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/14/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.7 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door O-XO, OX-O, O-OX, XO-O – Type 3 (144.039" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXO Cont. 144.039x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/21/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.8 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door OXXO – Type 4 (140.125" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXXO Cont. 140.125x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 11/08/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.9 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door OXXO - Type 4 (188.125" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXXO Cont. 188.125x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/21/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.10 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door Companion Fixed Window O – Type 1 (48.788" x 81.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_O Cont. 48.788x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 11/10/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.11 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (95.25" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 95.25x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/29/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.12 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Contemporary Sliding Door XO or OX – Type 2 (95.25" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Cont. 95.25x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/14/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.13 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door OXXO - Type 4 (236.125" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXXO Contemporary 236.125x119.5 CCL 411-H-1490.28.pdf Quality Assurance Contract Expiration Date 07/25/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.14 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door O-XO, OX-O, O-OX, XO-O – Type 3 (180.039" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXO Contemporary 180.039x119.5 CCL 411-H-1490.30.pdf Quality Assurance Contract Expiration Date 07/26/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.15 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (119.25" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-45 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 119.25x119.5 CCL 411- H-1490.35.pdf Quality Assurance Contract Expiration Date 10/13/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.16 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional Sliding Door Companion Fixed Window O – Type 1 (60.788" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-50 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_O Traditional 60.788x119.5 CCL 411- H-1490.33.pdf Quality Assurance Contract Expiration Date 10/07/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL12459-R11 Application Type Affirmation Code Version 2023 Application Status Approved Comments Archived Product Manufacturer Pella Corporation Address/Phone/Email 102 Main St. Pella, IA 50219 (641) 621-6096 pellaproductapproval@pella.com Authorized Signature Joe Hayden Sandi Robinson pellaproductapproval@pella.com Technical Representative Joseph Hayden Address/Phone/Email 102 Main Street Pella, IA 50219 (641) 621-6096 jahayden@pella.com Quality Assurance Representative Pat Bortscheller Address/Phone/Email 102 Main Street Pella, IA 50219 (641) 621-1000 PJBortscheller@pella.com Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency Window and Door Manufacturer Association Validated By T.E. Lunn, PE, LLC Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard)Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-11 2011 ASTM E1886-05 2005 ASTM E1886-13a 2013 ASTM E1996-12 2012 ASTM E1996-14 2014 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Approved Certification Agency FL12459_R11_Equiv_2016-01 Rev 2 Tech Bulletin E1996 and E1886 Equivalency.pdf I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes No N/A Product Approval Method Method 1 Option A Date Submitted 07/19/2023 Date Validated 07/19/2023 Date Pending FBC Approval Date Approved 07/23/2023 Summary of Products FL #Model, Number or Name Description 12459.1 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door Companion Fixed Window O – Type 1 (48.788" x 95.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Glass & glazing shall be as specified in the attached glazing detail “A”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_O Traditional 48.788x95.5 Hallmark AAMA_ASTM_TAS CCLs.pdf Quality Assurance Contract Expiration Date 11/10/2026 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing Detail A.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.2 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (95.25" x 95.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Glass & glazing shall be as specified in the attached glazing detail “A”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 95.25x95.5 Hallmark AAMA_ASTM_TAS CCLs.pdf Quality Assurance Contract Expiration Date 12/29/2026 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing Detail A.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.3 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (71.25" x 95.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: Glass & glazing shall be as specified in the attached glazing detail “A”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 71.25x95.5 Hallmark AAMA_ASTM_TAS CCLs.pdf Quality Assurance Contract Expiration Date 12/14/2026 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing Detail A.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.4 Pella/Architect Series and Pella/Architect Series Reserve Clad Traditional Sliding Door Companion Fixed Window O – Type 1 (60.788" x 119.5") Sliding Impact Glass Doors Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-50 Other: Glass & glazing shall be as specified in the attached glazing detail “B”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_O Traditional 60.788x119.5 Hallmark AAMA ASTM TAAS CCLs.pdf Quality Assurance Contract Expiration Date 10/03/2027 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing detail B.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.5 Pella/Architect Series and Pella/Architect Series Reserve Sliding Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (119.25" x 119.5") Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +35/-45 Other: Glass & glazing shall be as specified in the attached glazing detail “B”. These doors are impact rated to WindZone 4 Missile D Level. Glass meets the current ASTM E1300 standard. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 119.25x119.5 Hallmark AAMA ASTM TAAS CCLs.pdf Quality Assurance Contract Expiration Date 10/09/2027 Installation Instructions FL12459_R11_II_Drawing 1667.pdf FL12459_R11_II_Glazing detail B.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1667.pdf Created by Independent Third Party: Yes 12459.6 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door XO or OX – Type 2 (71.25" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Cont. 71.25x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/14/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.7 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door O-XO, OX-O, O-OX, XO-O – Type 3 (144.039" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXO Cont. 144.039x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/21/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.8 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door OXXO – Type 4 (140.125" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXXO Cont. 140.125x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 11/08/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.9 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door OXXO - Type 4 (188.125" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXXO Cont. 188.125x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/21/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.10 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door Companion Fixed Window O – Type 1 (48.788" x 81.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_O Cont. 48.788x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 11/10/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.11 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (95.25" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 95.25x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/29/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.12 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Contemporary Sliding Door XO or OX – Type 2 (95.25" x 95.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Cont. 95.25x95.5 Hallmark CCL Fin.pdf Quality Assurance Contract Expiration Date 12/14/2026 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.13 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door OXXO - Type 4 (236.125" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXXO Contemporary 236.125x119.5 CCL 411-H-1490.28.pdf Quality Assurance Contract Expiration Date 07/25/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44135 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.14 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional and Contemporary Sliding Door O-XO, OX-O, O-OX, XO-O – Type 3 (180.039" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_OXO Contemporary 180.039x119.5 CCL 411-H-1490.30.pdf Quality Assurance Contract Expiration Date 07/26/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.15 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional Sliding Door XO or OX – Type 2 (119.25" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-45 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_XO Traditional 119.25x119.5 CCL 411- H-1490.35.pdf Quality Assurance Contract Expiration Date 10/13/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes 12459.16 Pella/Architect Series and Pella/Architect Series Reserve Sliding Non-Impact Glass Doors Clad Traditional Sliding Door Companion Fixed Window O – Type 1 (60.788" x 119.5") Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-50 Other: Configurations of glass shall conform to the current ASTM E1300 standard with all glass being safety glazing. Certification Agency Certificate FL12459_R11_C_CAC_O Traditional 60.788x119.5 CCL 411- H-1490.33.pdf Quality Assurance Contract Expiration Date 10/07/2027 Installation Instructions FL12459_R11_II_Drawing 1666.pdf Verified By: Warren W. Schaefer 44139 Created by Independent Third Party: Yes Evaluation Reports FL12459_R11_AE_Drawing 1666.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: