No preview available
 /
     
1177 Atlantic Blvd DWAY25-0008 PermitOWNER:ADDRESS:CITY:STATE:ZIP: HULIHAN TERRITORY INC 1177 ATLANTIC BLVD ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: HULIHAN TERRITORY 1177 ATLANTIC BLVD ATLANTIC BEACH FL 32233 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170708 0000 ATLANTIC BEACH SEC H JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1177 ATLANTIC BLVD DRIVEWAY COMMERCIAL DRIVEWAY CONCRETE DRIVEWAY $10000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878. State Law requires calling Sunshine 811 to have ALL public utilities located BEFORE beginning the work. 2 PUBLIC UTILITIES ADDITIONAL COMMENTS PUBLIC UTILITIES INFORMATIONAL Notes: See Revocable Encroachment Agreement regarding driveways/pavers and public utilities in the ROW NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 3Issued Date: 4/4/2025 PERMIT NUMBER DWAY25-0008 ISSUED: 4/4/2025 EXPIRES: 10/1/2025 DRIVEWAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 3 PUBLIC WORKS DRIVEWAY APRON INFORMATIONAL Notes: All concrete driveway aprons must be 5 inches thick, 4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the City right-of-way. 4 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 5 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 6 PUBLIC WORKS POST CONSTRUCTION TOPO SURVEY INFORMATIONAL Notes: If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 7 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. 8 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. Full site to be grassed. 9 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 10 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 11 PUBLIC WORKS DOCUMENT IMPERVIOUS AREA INFORMATIONAL Notes: Strongly suggest thorough documentation of impervious areas be recorded. 12 PUBLIC WORKS SLAB DRIVEWAY REMOVAL INFORMATIONAL Notes: Slab and driveway to be fully removed. 13 PUBLIC WORKS MAXIMUM DRIVEWAY INFORMATIONAL Notes: Maximum driveway width within the City right-of-way is 20 feet. 2 of 3Issued Date: 4/4/2025 PERMIT NUMBER DWAY25-0008 ISSUED: 4/4/2025 EXPIRES: 10/1/2025 DRIVEWAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT PU REVIEW BUILDING MOD OR ROW 001-0000-329-1007 0 $25.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 ZONING REVIEW COMMERCIAL AND INDUSTRIAL USES 001-0000-329-1003 0 $350.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $500.00 14 PUBLIC WORKS TOPO SURVEY INFORMATIONAL Notes: Must provide a topographic (TOPO) survey with water retention for final C.O. Inspection. 15 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 16 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 17 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 18 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 19 PUBLIC WORKS PROPERTY LINE - WATER RETENTION INFORMATIONAL Notes: Water retention must have a minimum of 10 feet offset from structure unless a letter is provided by an Engineer stating that the structure will have no impact from the water retention. Must have a minimum of 2 feet offset of water retention from front and rear property lines and a minimum of 5 feet offset of water retention from side property lines. 20 PUBLIC WORKS WATER RETENTION INFORMATIONAL Notes: Water retention areas must be sodded prior to inspection. 3 of 3Issued Date: 4/4/2025 PERMIT NUMBER DWAY25-0008 ISSUED: 4/4/2025 EXPIRES: 10/1/2025 DRIVEWAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 rsA' BUILDING PERMIT APPLICATION FOR INTERNAL OFFICE USE ONLY A Ci ty of Atlantic Beach Building Department PERMIT# Lam- k•O1 f25 -0045 r5v800 Seminole Road, Atlantic Beach, FL 32233 ALL information required to process rni Phone: (904) 247-5826 Email: Building-Dept( coab.us Job Address 1177 Atlantic Blvd RE# 170708 0000 Legal Description 18-34 18-2S-29E .187 ATLANTIC BEACH SEC H PT BLK 10 RECD 0/R 9686-291 ic Valuation of Work(Replacement Cost) , ...ii-.-1//0 j U0 6 Heated/Cooled SF Non-Heated/Cooled SF Class of Work: New 17 Addition EAlteration X Repair Move ['Demo Pool Window/Door Use of existing/proposed structure(s): X Commercial Residential • If existing structure, is a fire sprinkler system installed?:yes X No Will tree(s) be removed in association with proposed project? Yes (Must submit separate Tree Removal Permit) x No Describe in detail the type of work to be performed: remove driveway and replace concrete widen aprox 4 feet.see attatched drawing for underground retention to account for change in impoervious area. remove parking pad and replace concrete 0_0 NG.,t-e_A Q, di 1,0 LI Florida Product Approval# For multiple products use Product Approval Information Sheet) PROPERTY OWNER Name HULIHAN TERRITORY INC Phone 904 955 8320 Address 1177 ATLANTIC BLVD City ATLANTIC BEACH State FL Zip 32233 Email CODY@HULIHANTERRITORY.COM Owner or Agent CODY T DUBIN T-[CONTRACTOR Name of Company v 1ikci Terr 1-c/ -T. 1-t (_, Phone Address 17 7 4 -Ianf;C. B ival City 44-`pnv<,aje4cin State PI— Zip 32233 Qualifying Agent ff J_ , 1 State Certification/Registration# Email G pdy [6h,J vlterrI TCr .c 0--.1 Job Site Contact Number q01-1— Q 5 S— X320 Worker's Compensation Insurer FC. `?j .. OR Exempt Expiration Date 3/2 g/26 Engineer of Record Architect of Record Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS,FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this city/county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE SITE OF THE IMPROVEMENT BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. In lieu of signed, sworn and notarized signatures of the property owner,agent and/or contractor, and under penalties of perjet4,.. I declar hat I have read and examined the foregoing application and that the facts stated in it are true and correct." COth O,b;-3 - 6—Z0273^ SIGNA URE F CO" •ACTOR PRINT OR TYPE NAME OF CONTRACTOR DATE i Loci Dvhin 3-(-2025 SIGNATURE * •WNER OR AGENT PRINT OR TYPE NAME OF OWNER OR AGENT DATE Building Permit Application 11.05.2024 i IlTLIThT\( BLvi TDTd& LAT 1AE tA: 103 5 x (29 = Pk t 1.5o sc 1,Ktr loos okt,cx.eb : 101.. = 5,134 4' EXisfinc 1ivxPtrvwv gv.Mirtg 35,2 x l0.3 2,414.56 Concrek 1243.t'L 1543 .2 21.5 2.8 = 110. 0 14181.`t ,tc Prbpostel 164,1N/if.,s Zr;ldir,g 3s. 2 x 10.3 = 2,L 1LLg. male 12g X Il, =Z,051.(,o 21.5 35.2 - 9U V .04-) 5,50o.IL. Toil; lof co t,et 5,9ztoAL. / coq. 51500.1t, — 4,1(6"1.1ca = 14 Tof4l Vo ki isrei unibly ncedec( 501 cc Public Works Approved 03/14/2025 67% max at 70% commercial property OYtI{1c w I 15 S From, dowi sPa s 10'-- Z 4S " I I RQien'ho-- Ares. : tS.5 x zts = to91.5 s4 12Q*LAtio•-. Valvate•. Vp= 21S' or re Pw ted K Z Zt x .19 VQ= tco8 e' Vg ts41.5 x l•S 1,OL4t,.25 c4 - ikot = S'1$ .tS ug 1 V.25 x .4 = 2A-1 cc VT = Vp 4 Vt 1u8 t x,51 511 cf Public Works Approved 03/14/2025 12" Dual wall corrugated/perf pipe au ..SKJCI i uin-.z i IMP 06T 00. f•, ti ti• i KWGM L'n t h K..WS*ill......,u 4 ONO One WI in dOLS OMI p.( i L. y a... m gg Al r q2 011 n CO z a y 0 gi dm t 1------ D o o A4 z C 4rK 9 0i t St I w I 0 K., ..o,•..... mW w. v ax.0 a 10 N10 owl L' 10 1.2101S0M1 I p i " co N 1.01 t lit I U N 2JIIIHX3 k 11 Will 1.2rt0.6iN) I09Y9 1''1 1.424m-3.00,tae - - - . .:.:r;.. ' :cilia'-1-0—.136I. ars - ---.. 2.6311..1 N A. .. an)n5 \last;`a0 Public Works Approved 03/14/2025 Public Works Approved03/14/2025 Public Works Approved 04/02/2025 Received by Building 03/20/2025 Public Works Approved 04/02/2025