Loading...
324 AQUATIC DR RESA25-0006 FL21443-R5 REV 5-29-25STRUCTALL BUILDING SYSTEMS PANEL SPAN TABLES: 1 MULTIPLY ULTIMATE LEIADS BY 0.6 FOR ALLE)WABLE LEIADS 3" x 0,024 x 1 - LB EPS PANELS (OPEN STRUCTURE -EXPOSURE B) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX, L/60 & L/80 ALLOWABLE SPAN L/120 L/180 (FT) L/240 110 20.4 16.95 16.40 14.08 12.36 120 1 24.3 15.90 15.36 13.04 11.32 130 28.5 15.00 14.40 12.08 10.36 140 33.1 13.83 13.51 1 11.19 9.47 150 38.0 12.76 12.68 10.37 8.64 160 43.2 12.01 11.90 9.59 7.87 180 54.7 10.91 10.49 8.18 6.45 3" x 0,024 x 1 - LB EPS PANELS (ATTACED STRUCTURE -ENCLOSED OR PARTIALLY OPEN -EXPOSURE B) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALLOWABLE SPAN L/60 & L/80 L/120 L/180 (FT) L/240 110 16.3 18.32 17.75 15.43 13.71 120 19.4 17.36 16.71 14,39 12.66 130 22.8 16.29 15.74 13.42 11.70 140 1 26.4 15.77 14.86 1 12.54 10.82 150 30.4 14.52 14.01 1 11.70 9.97 160 34.5 1 13.47 13.25 10.94 9,21 180 43.7 1 12.03 11.83 9.52 7.79 3" x 0,024 x 1 - LB EPS PANELS (ATTACHED STRUCTURE -OPEN & ATTACHED UNDER EASICA/OVERHANG) (EXPOSURE B) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX, L/60 & L/80 ALLOWABLE SPAN (FT) L/120 L/180 L/240 110 11.5 21.80 19.85 17.52 15.80 120 13.7 20.21 18.80 16.48 14.75 130 1 16.0 18.74 17.87 15.54 13.82 140 18.6 17.37 16.96 14.64 12.92 150 21.3 16.75 16.15 13.83 12.10 160 24.3 16,04 15.36 13.04 11,31 180 30.7 14.51 13.95 11.64 9.91 3" x 0,024 x 1 - LB EPS PANELS (OPEN STRUCTURE -EXPOSURE C) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. L/60 & L/60L/120 ALLOWABLE SPAN L/180 (FT) L/240 110 30.4 14.52 14.01 11.70 9.97 120 1 36.2 13.34 12.96 10.65 832 130 42.5 12.19 12.00 9.69 7.96 140 49.3 11.56 11.11 8.80 7,07 150 56.6 10.88 10.28 7.79 6.24 160 64.4 10.09 9.50 7.19 5.47 180 81.5 8.60 8.10 5.78 4.06 3" x 0,024 x 1 - LB EPS PANELS (ATTACED STRUCTURE -ENCLOSED OR PARTIALLY OPEN -EXPOSURE C) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/60 & L/BO L/120 L/180 L/240 110 24.3 16.04 15.36 13.04 11.31 120 29.0 14.70 14.29 11.98 10.25 130 34.0 13,71 13.34 11.02 9.30 140 39.4 1 12.76 1 12.45 10.14 1 8.42 150 45.3 1 11.97 1 11.61 9.30 7,58 160 51.5 1 11,20 1 10.84 1 8,54 6,81 180 65.2 1 9.94 1 9.43 1 7.12 5,40 3" x 0,024 x 1 - LB EPS PANELS (ATTACHED STRUCTURE -OPEN & ATTACHED UNDER EASICA/OVERHANG) (EXPOSURE C) WIND SPEED NET ULTIMATE LOAD (PSF)1L/67& MAX. ALLOWABLE SPAN (FT) L/60 & L/60 L/7-�L/120 L/180 L/240 110 17.1 17.98 17.47 15.15 13.42 120 20.4 16.85 16.41 14.09 12.36 130 1 23.9 16.22 15.46 13.14 11.41 140 27.7 15.21 14.57 12.25 10.53 150 31.8 14.13 13.74 1 11.43 1 9.70 160 36,2 1 13.07 1 12.96 1 10.65 1 8.92 180 45.8 1 11.80 1 11.55 1 9.24 1 7.51 he Attached Covers (canopies) on Buildings I . Roof covers attached to fascia are deemed 0.9 < hc/he < 1. 2. Roof covers attached to the host structure underneath the fascia and overhang at deemed 0.5 < hc/he < 0.9. PRODUCT APPROVAL DETAILS: BLDG CODE: 8th EDITION FLORIDA BUILDING CODE (2023 FBC) LIMITS OF USE: FOR PATIO USE ONLY (RISK CATEGORY I). -CARPORTS -PATIO COVERS -SUNROOMS -SCREEN ENCLOSURES -CANOPIES -OTHER SIMILAR MINOR STRUCTURES Note All product performance specifications and construction requirements shall be engineered by a licensed design professional in accordance with the Aluminum Design Manual, Specifications & Guidelines for Aluminum Structures, Washington, DC, for wind resistance in conformance to FBC Chapter 16 for Components and Cladding Loads, ASCE/SEI 7-22 Chapter 30 for Components and Cladding for Open Buildings, Partially Open Buildings, and Attach Canopies on Buildings. Effective area for wind load calculations based on 50 sq. feet (absolute value of controlling design wind pressure is shown on span tables). DO KIM I & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Tel: (813) 857-9955 Rev./Date Description 0 10/15 ISSUED FOR PRODUCT 2020 APPROVAL 8/13 ISSUED FOR PRODUCT 0 2023 APPROVAL -8th EDITION FBC 0 m 2. Span schedule show maximum roof panel spans between two sided clear supports as shown. 0 3. Wind load design pressures in span tables are calculated in accordance to ASCE/SEI 7-22, Components & Cladding loads as required in FBC Table 2002.4. Mean roof height of structure shall not exceed 15 feet above grade. Span tables for open and partially open structures based on 7.5° max. roof slope and used the avg. of free flow and obstructed flow net pressure coefficients. Span tables for enclosed structures based on 10° max. roof slope. 4. Each roof panel shall be connected per design professional's instructions, but may use min. per details shown on this dwg. at each support (or other approved connection by design professional) w/ min. 0.040" thick, 6063-T6 aluminum base metal. Edge panels shall be supported on min. three sides or per design professional's instructions. Details 1 & 2 are reflective of the boundary conditions utilized in the testing of panels as referenced in the test reports. 5. Composite panels shall be constructed using type 3105-H154 aluminum facings, 1 or 2 PCF ASTM C-578 Imperial Foam & Insulation Manufacturing brand EPS adhered to aluminum facings with Morad M640 Series adhesive (by Rohm and Haas Company). Fabrication to be by Structall panel products only in accordance with approved fabrication methods. 6. Structall roof panels maintain a UL 1715 (int) class 'B' (ext) rating and are NER-501 approved. 7. This specification has been designed and shall be fabricated in accordance with the requirements of the Florida Building Code 8th Edition (2023 FBC), composite panels comply with Chapter 7 Section 720, Chapter 8 Section 803, Class A interior finish, and Chapter 26 Section 2603. All local building code amendments shall be adhered to as required. 8. The designer shall determine by accepted engineering practice the design loads for site specific load conditions (including load combinations) using the data from the loads tables and spans in this ti ti Q0 co J LL M E w O U Q O LL U) D - w m J X N 0 CD x i� 1 DRAWN BY: DYK Digitally signed by Do Y Kim Do Y Ki m Date: 2023.08.13 12:00:51 Drawing No. - 202001 -04'00' SHEET 1 OF 2 approval. CHECKED BY: DYK 9. Deflection limits and allowable spans have been listed to meet FBC including the HVHZ. In HVHZ, SCALE: AS SHOWN this product shall be used in structures meeting the requirements of Section 1626. 1, unless impact DATE: 10/19/16 resistance in accordance to the HVHZ requirements are met. 10. Safety factor of 2.0 has been use to develop allowable loads and spans from testing in accordance to the Guidelines for Aluminum Structures Part 1 and conforms to the FBC Chapter 16 and 20. 11. Testing has been conducted in accordance to ASTM E72: Strength Test of Panels for Building DO YEON KIM, P.E. Construction. FLA. REG. NUMBER 49497 12. Linear interpolation shall be allowed for figures within the tables shown. 13. Panels with fan beams shall be considered equivalent to similar panels without fan beams. Desi q p � DO KIM &ASSOCIATES, LLC cA# 26887 professionals may include the strength of the fan beam to exceed shown figures as part of site-specific engineering. PO BOX 10039 Tampa, FL 33679 14. Reference test reports conducted by PRI -Construction Materials Technologies LLC., 6412 Badger Drive, Tampa, FL 33610, (813) 621-5777 can be found in the product evaluation report (FL#21443). Digitally signed by Do Y Kim Do Y Ki m Date: 2023.08.13 12:00:51 Drawing No. - 202001 -04'00' SHEET 1 OF 2 #10xLENGTH (PANEL DEPTH+11) S.M.S. W/ 1Y4'0 FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. / (EXTERIOR) O O O O O O O O O <> O O O O O O 0 0 0 0 0 0 0 0 d O O O O O O O O O �> O 00000000 00000000000<>0000 (INTERIOR) HEADER/EAVE RAIL MIN. 3x2xO.045 nCTAII 7 SEAL J❑INT WITH CONTINUOUS CAULKING 0000c�000000 )0 01000000C DETAIL 1 w SL❑PE o' O O O O O �1 00 00000000 v O_O�O_O_O_O_ 0 COMPOSITE ROOF PANELS INTERLOCKING CROSS SECTI❑N DETAIL 2 4' MAX WIDTH INTERLOCKING PANEL (1/4'/FT MIN SLOPE) J as LJ I— z CL EPS CORE Q LU a_Q If ALUMINUM BOTTOM— FACINGS CLEAR SPAN (L) INSIDE TO INSIDE ENGINEER OF RECORD TO PROVIDE ALL ROOF CONNECTIONS & ADD THICKNESS OF SUPPORTING STRUCTURE DETAILS WALL FOR TOTAL IN ADDITION TO AND IN -LIEU OF PANEL SPAN: DETAILS SHOWN. SEALANT --\ 3/4' MAX, #14xYz' SMS W/ INTEGRAL 3/4'0 WASHERAND NEOPRENE GASKET @ 12" O.C. TOP & BOTTOM, ❑PTI❑NAL GUTTER OR DRIP CAP 011 0-0 =11 O.H. 36' MAX IN FRONT & 25% ❑F PANEL WIDTH @ SIDES (12' MAX AT SIDES) 1 11111 1 1111! 1 10 "01 =011 10 01-11 14" FLASHING (CONT,) TUCK UNDER SHINGLED @ LEAST 6' EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044' MIN. THICKNESS) WITH MIN. 1Y2' BEARING LEG. (1) Y4"0 x 2" LAG SCREW @ 24" O.C. ENTIRE LENGTH OF RECEIVING CHANNEL SECURE FASCIA T❑ EACH RAFTER TAIL W/ (1) WO x 4" LONG PAN HEAD LAG SCREWS BEFORE ATTACHING RECEIVING CHANNEL SOFFIT C SEALANT Ya' 0 x 2Ya" LONG WOOD LAG SCREW OR SLOPE° < ° Ya' 0 x 2Y4' LONG MASONRY ANCHORS . � @ 24' O.C. MAX, 000000000000... 0 0 0 0 0 ° HOST STRUCTURE O' O � O' O — O O e° (MASONRY OR WOOD) #14xY2' S.M.S. W/INTEGRAL 3/4"0 WASHER ANDEXTRUDED OR BRAKE -FORMED ROOF HEADER NEOPRENE GASKET@ 12" O.C., TOP & BOTTOM. a OR RECEIVING CHANNEL (0.044" MIN, THICKNESS) IF CLEARANCE PROHIBITS INSTALLATION OF TOP ° WITH MIN. 1Y2' BEARING LEG. FASTENERS USE #14x4" S.M.S. W11Y4" 0 FENDER WASHER AND NEOPRENE GASKET @ 12" O.C. DETAIL 1 DO KIM I & ASSOCIATES, LLC CONSULTING I STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Tel: (813) 857-9955 Rev./Date Description 0 10/15 ISSUED FOR PRODUCT 2020 APPROVAL 8/13 ISSUED FOR PRODUCT 0 2023 APPROVAL -8th EDITION FBC 0 F 0 DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 10/19/16 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CA# 26887 PO BOX 10039 Tampa, FL 33679 EPS ROOF PANEL/ SPAN DESCRIPTION Drawing No. - 202001 SHEET 2OF2 J _3O Lu Lu QY �za to �dQ ti Z H — U `S U) 't Opo co LL 20 LL L Z Lu Lu m m Q o O x w w i O Cn H (n CD O (n i) r) 0E O J LL DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 10/19/16 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CA# 26887 PO BOX 10039 Tampa, FL 33679 EPS ROOF PANEL/ SPAN DESCRIPTION Drawing No. - 202001 SHEET 2OF2