Loading...
324 AQUATIC DR RESA25-0006 PERMITOWNER:ADDRESS:CITY:STATE:ZIP: MEEKER MICHELLE ANDREA 324 AQUATIC DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: Great Day Improvements, LLC dba Patio Enclosures 8813 Venture Cove Tampa FL 33637 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171818 5108 AQUATIC GARDENS JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 324 AQUATIC DR RESIDENTIAL ADDITION SINGLE OR TWO FAMILY RESIDENTIAL ADDITION SCREEN ROOM WITH ALUMINUM ROOF $8856.57 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS NOTICE OF COMMENCEMENT INFORMATIONAL Notes: No inspections may be scheduled until a copy a recorded Notice of Commencement has been submitted to the Building Department NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/5/2025 PERMIT NUMBER RESA25-0006 ISSUED: 6/5/2025 EXPIRES: 12/2/2025 RESIDENTIAL ADDITION PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $95.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $47.50 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.89 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $397.39 2 of 2Issued Date: 6/5/2025 PERMIT NUMBER RESA25-0006 ISSUED: 6/5/2025 EXPIRES: 12/2/2025 RESIDENTIAL ADDITION PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Do Kim &Associates,LLC Product Evaluation Commentary Consulting Structural Engineers FBC FL#21443-R5 P.O. Box 10039, Tampa, FL 33679 Issued February 2024 (813) 857-9955 | dk@dokimengineering.net P.O. Box 10039 813.857-9955 Tampa, FL 33679 dk@dokimengineering.net Page 1 of 1 EVALUATION SUBJECT: Structall Building Systems EPS Foam Core Composite Aluminum Skin Panel Florida Statewide Product Approval Installation Drawings. FL#21443-R5 Compliance with the following codes: 8th Edition Florida Building Code (FBC) COMMENTARY REGARDING USE OF INSTALLATION INSTRUCTION TABLES Questions regarding the use and reading of the span tables to arrive at the appropriate span for the desired design load pressure has been raised. This commentary has been issued to clarify the correct method on how to use the tables with the appropriate design loads and their corresponding maximum spans. The first step is to determine the design wind speed and the Exposure. Find the appropriate table for the panel type, type of structure (open, enclosed, etc.), and Exposure. 1.Once the table is selected, locate the design wind speed. The row with wind speed, find the maximum deflection limit allowed by the code for the structure being designed. The span under the selected deflection limit is the maximum allowable span. 2. The term “allowable” in the heading “MAX. ALLOWABLE SPAN” is not related to design method. It’s meaning is just plan Webster English Dictionary meaning. It does not relate to Strength or Allowable Design methodology. The 0.6 reduction factor to convert Ultimate to Allowable is not used for Spans. The span figures in the tables never gets modified. 3.The term NET ULTIMATE LOAD in the tables are the design loads (pressures) that are derived from ASCE 7 and/or FBC. The term NET is the combination of all the loads from the controlling load combination from ASCE 7/FBC. In the calculations for patio structures, the dead load for the panels is assumed minimal. The load combination that usually controls is dead load plus wind load. But the design professional should verify for their particular structure design. 4.If the designer is using Allowable Strength Design in their overall design of the structure and wishes to get the Allowable Loads for the design of other components in their structure, this note is just a reminder to multiply the load (PSF) in the NET ULTIMATE LOAD column by 0.6 to convert the load to allowable stress design so that the designer can calculated the allowable loads imposed on the panels to design other elements such as foundations, connections, MWFRS, and attachments to existing host structures. ***