Loading...
1751 ATLANTIC BEACH DR POOL25-0023 TDHProject No. : 2515304 Project Name : KELEHER Project Address : 1751 ATLANTIC BEACH DR, ALTANTIC BEACH FL32233 POOL/ SPA HYDRAULICS WORKSHEET DESIGN CIRCULATION FLOW PARAMETERS: 1. Pool circulation volume :≔V =+⋅⋅12 ft 8 ft 3.75 ft ⋅⋅6 ft 8 ft 3.5 ft 3949.714 gal 2. Preferred turnover rate:≔t =6 hr 360 min 3. Pool circulation flow rate :≔Qp =―V t 10.971 gpm Add water feat. flow rate,≔Qwf 0 gpm Total circulation flow rate,≔Qc =+Qp Qwf 10.971 gpm 4. Spa Jets:Number of jets,≔n 6 [Max.] ≔Qjet =⋅n 12 gpm 72 gpm (For single pump pool / spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool and spa.) Minimum design flow rate ≔Qmin 36 gpm Pool/ Spa pump flow rate ≔Q =+Trunc ⎛⎝,max ⎛⎝,,Qc Qmin Qjet⎞⎠1 gpm ⎞⎠1 gpm 72 gpm PIPE SIZES & SIMPLIFIED TDH: Page 1 of 3 &ůŽƌŝĚĂŶŐŝŶĞĞƌŝŶŐ>> ϰϭϲϭdĂŵŝĂŵŝdƌĂŝů͕^ƵŝƚĞϭϬϭ͕WŽƌƚŚĂƌůŽƚƚĞ͕&>ϯϯϵϱϮͲϵϮϬϰ ǁǁǁ͘ĨůĞŶŐ͘ĐŽŵ ͮWŚŽŶĞ͗;ϵϰϭͿϯϵϭͲϱϵϴϬ >ŝĐĞŶƐĞEƵŵďĞƌηϯϬϳϴϮ͕ηϲϬϭϬϮ 5LFKDUG(:DONHU3( PIPE SIZES & SIMPLIFIED TDH: Pool/ Spa pump max. flow rate: =Q 72 gpm Pipe Sizes Per 2023 FBC, 8th Edition: Main Drain (Branch) Piping: 2.5"to keep velocity @ 6 fps max at flow rate = max.88 gpm Main Drain (Trunk) Piping: 2.5"to keep velocity @ 8 fps max at flow rate = max. 117 gpm Skimmer Piping: 2.5"to keep velocity @ 8 fps max at flow rate = max. 117 gpm Std. Return Piping: 2.0"to keep velocity @ 10 fps max at flow rate = max. 103 gpm Spa Jets Piping: 2.0"to keep velocity @ 10 fps max at flow rate = max.103 gpm The distance of the pool equipment pad from the nearest edge of the pool = . (max.)40 ft 1. Friction loss (suction/trunk pipe)2.5"pipe per ft. at ≔fsuction 0.09 2. Friction loss (return pipe)2.0"pipe per ft. at ≔freturn 0.16 3. Length of suction pipe ≔Lsuction 70 ft TDH in suction pipe ≔TDHsuction =⋅Lsuction fsuction 6.3 ft 4. Length of return pipe ≔Lreturn 100 ft TDH in return pipe ≔TDHreturn =⋅Lreturn freturn 16 ft 5. TDH in Piping ≔TDHpiping =+TDHsuction TDHreturn 22.3 ft 6. Filter loss in TDH ≔TDHfilter 7 ft 7. Heater loss in TDH ≔TDHheater 10 ft 8. All other losses ≔TDHother 16 ft ...head losses in fittings, etc 9. Total simplified TDH ≔TDH =+++TDHpiping TDHfilter TDHheater TDHother 55.3 ft Filter (As Listed or Equal):Pentair RP150 Cartridge Page 2 of 3 Filter (As Listed or Equal):Pentair RP150 Cartridge Pool/ Spa Pump (As Listed or Equal): Manufacturer : Pentair Model : whisperFlo VS Size / HP = 2.6 Maximum flow rate,=Q 72 gpm Total simplified TDH,=TDH 55.3 ft Main Drain Cover (As Listed or Equal): Manufacturer : CMP Model : Nova Drain Max. cover flow rate (floor) = 150 gpm Cover Replacement Date = 7 years Notes : 1. In flow suction outlets cover/grate must conform to most recent edition of ASME/ANSI A112.19.8 and be embossed with that edition approval. Single drains shall be unblockable. 2. Center to center spacing of multiple drains shall be at least 3'-0". 3. Pump and Filter make, model and location cannot change without submitting a revised plan TDH worksheet. Page 3 of 3