Loading...
1828 ATLANTIC BEACH DR RES25-0208 Duct LayoutsJob #: Performed for: Alderman Residence Atlantic Beach Dr Fernandina Beach, FL Exclusively for the use of: Hallco Heating & Air LLC Scale: 1 : 100 Page 1 Right-Suite® Universal 2022 22.0.07 RSU17457 2025-Aug-04 14:39:31 ..., Atlantic Beach Dr, Atl Bch.rup N 1st Floor Owner Ste Owner Bath WIC 2 WIC 1WC Study Pantry Laundry KitchenDining Living Foyer Powder Mud Hall 1 Stairs 1 79 cfm 130 cfm 104 cfm 27 cfm 63 cfm 33 cfm 109 cfm 81 cfm 1085 cfm 81 cfm 22 cfm 115 cfm 115 cfm 99 cfm 6 " 5 " 7 " 4 " 7 " 7 " 5 " 7 " 4 " 6 " 4 " 16 " 5 " 12 " 20 " 6 " 48 cfm 48 cfm 5 " 5 " 24 cfm24 cfm 4 " 4 " 33 cfm4 " 49 cfm 5 " NOTE: HVAC Contractor to verify in field duct la yout compatibility with building structure and coordinate installation with other trades. Job #: Performed for: Alderman Residence Atlantic Beach Dr Fernandina Beach, FL Exclusively for the use of: Hallco Heating & Air LLC Scale: 1 : 100 Page 2 Right-Suite® Universal 2022 22.0.07 RSU17457 2025-Aug-04 14:39:31 ..., Atlantic Beach Dr, Atl Bch.rup N 2nd Floor Train Room Ste 4 Ste 3 Bath 3 Ste 2 Bath 2WIC Ste 2 WIC 3 WIC 4 Bath 4 Laundry 2 Hall 2 111 cfm 34 cfm 85 cfm 45 cfm 9 cfm 27 cfm 4 cfm 5 cfm 97 cfm97 cfm 103 cfm 235 cfm 162 cfm 160 cfm 158 cfm 42 cfm 42 cfm 8 " 6 " 8 " 6 " 7 " 6 " 4 " 6 " 5 " 4 " 6 " 4 "4 " 4 " 5 " 4 " 9 " 10 " 10 "12 " 23 cfm 4 " NOTE: HVAC Contractor to verify in field duct la yout compatibility with building structure and coordinate installation with other trades. Bold/italic values have been manually overridden 2025-Aug-04 14:39:18 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 1 ...erman Residence, Atlanti c Beach Dr, Atl Bch.rup Calc = MJ8 Front Door fac es: NE Job:Duct System Summary Date: 1st Floor By: Exclusively for the use of:, Hallco Heating & Air LLC Project Information Alderman ResidenceFor: Atlantic Beach Dr, Fernandina Beach, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.445 / 0.055 in H2O in H2O0.445 / 0.055 Lowest friction rate in/100ft0.148in/100ft0.148 Actual air flow cfm1085cfm1085 Total effective length (TEL)ft337 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1190.042.0VlFx0x07.00.192911302988hDining st1230.047.0VlFx0x07.00.161841042382hFoyer st190.05.0VlFx0x04.00.469330679cHall 1 st1190.022.0VlFx0x05.00.210480995cKitchen st1190.029.0VlFx0x05.00.203480995cKitchen-A st1150.013.0VlFx0x04.00.273240498cLaundry st1250.050.0VlFx0x07.00.1481031152649hLiving st1250.041.0VlFx0x07.00.1531031152649hLiving-A st1110.023.0VlFx0x05.00.33544631443hMud st2150.014.0VlFx0x05.00.27144491133hOwner Bath st2130.018.0VlFx0x05.00.30169811871hOwner Ste st2130.030.0VlFx0x06.00.27869811871hOwner Ste-A st1150.020.0VlFx0x04.00.262240498cPantry st1170.030.0VlFx0x04.00.2231927618hPowder st1210.037.0VlFx0x06.00.18081992278hStairs 1 st1130.026.0VlFx0x05.00.28561791813hStudy st2110.08.0VlFx0x04.00.377220452cWC st290.013.0VlFx0x04.00.4322733761hWIC 1 st2150.023.0VlFx0x06.00.257911092513hWIC 2 2025-Aug-04 14:39:18 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 2 ...erman Residence, Atlanti c Beach Dr, Atl Bch.rup Calc = MJ8 Front Door fac es: NE Supply Trunk Detail Table Tru nk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Tru nk st1 Peak AVF 731 764 0.148 547 16.0 0x0 VinlFlx st2 Peak AVF 354 321 0.257 451 12.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Tru nk rb2 0 x 10850 1085 37.0 0.148 497 20.0 x0 0 VlFx Bold/italic values have been manually overridden 2025-Aug-04 14:39:18 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 3 ...erman Residence, Atlanti c Beach Dr, Atl Bch.rup Calc = MJ8 Front Door fac es: NE Job:Duct System Summary Date: 2nd Floor By: Exclusively for the use of:, Hallco Heating & Air LLC Project Information Alderman ResidenceFor: Atlantic Beach Dr, Fernandina Beach, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.360 / 0.140 in H2O in H2O0.360 / 0.140 Lowest friction rate in/100ft0.187in/100ft0.187 Actual air flow cfm710cfm710 Total effective length (TEL)ft267 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st3110.021.0VlFx0x04.00.2743434612hBath 2 st4160.015.0VlFx0x05.00.2054445808hBath 3 st3110.09.0VlFx0x04.00.30294178cBath 4 70.07.0VlFx0x04.00.4674239819cHall 2 st3130.020.0VlFx0x05.00.2404239819cHall 2-A st3150.029.0VlFx0x04.00.2012627476hLaundry 2 st4150.024.0VlFx0x06.00.2071051111975hSte 2 st4130.019.0VlFx0x06.00.2411011031830hSte 3 st390.018.0VlFx0x06.00.33385851512hSte 4 st3150.020.0VlFx0x06.00.21294971718hTrain Room st3160.032.0VlFx0x06.00.18794971718hTrain Room-A st4110.06.0VlFx0x04.00.3104286cWIC 3 st3110.010.0VlFx0x04.00.3005299cWIC 4 st490.016.0VlFx0x04.00.3392323452cWIC Ste 2 Supply Trunk Detail Table Tru nk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Tru nk st3 Peak AVF 386 390 0.187 497 12.0 0x0 VinlFlx st4 Peak AVF 285 278 0.205 522 10.0 0x0 VinlFlx 2025-Aug-04 14:39:18 Right-Suite® Universal 2022 22.0.07 RSU17457 Page 4 ...erman Residence, Atlanti c Beach Dr, Atl Bch.rup Calc = MJ8 Front Door fac es: NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Tru nk rb3 0 x 2350 234 38.0 0.370 533 9.0 x0 0 VlFx rb4 0 x 1570 162 57.0 0.246 463 8.0 x0 0 VlFx rt2 rb5 0 x 1590 160 75.0 0.187 458 8.0 x0 0 VlFx rt2 rb6 0 x 1580 155 55.0 0.255 590 7.0 x0 0 VlFx Return Trunk Detail Table Tru nk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Tru nk rt2 Peak AVF 317 322 0.187 590 10.0 0x0 VinlFlx