Loading...
1828 ATLANTIC BEACH DR RES25-0208 Energy Calcs with Signatures REV 9-23-25FORM R405-2023 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Alderman Residence Builder Name: Street: Atlantic Beach Dr Permit Office: Atlantic Beach City, State, Zip: Atlantic Beach, FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL, MAYPORT_NS County: Duval(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10, Wall Types(4166.8 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=5.0 2073.00 ft2 b. Frame - Wood, Exterior R=19.0 1634.40 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=19.0 459.38 ft2 4. Number of Bedrooms 4 d. N/A 5. Is this a worst case? No 11. Ceiling Types(2796.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2796.00 ft2 6. Conditioned floor area above grade (ft') 4422 b. N/A Conditioned floor area below grade (ft') 0 c. N/A 7. Windows(625.9 sqft.) Description Area 12. Roof(Metal, Unvent) Deck R=20.0 3237 ft2 a. U -Factor: Dbl, U=0.40 625.92 ft2 13. Ducts, location & insulation level R ft2 SHGC: SHGC=0.25 a. Sup: Attic, Ret: Attic, AH: 1st Floor 6 363 b. U -Factor: N/A ft2 b. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 211 SHGC: C. c. U -Factor: N/A ft2 14. Cooling Systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER2:15.20 Area Weighted Average Overhang Depth: 6.546 ft b. Central Unit 23.2 SEER2:15.20 Area Weighted Average SHGC: 0.250 8. Skylights Description Area 15. Heating Systems kBtu/hr Efficiency U-Factor:(AVG) N/A N/A ft2 a. Electric Heat Pump 33.8 HSPF2:7.80 SHGC(AVG): N/A b. Electric Heat Pump 22.4 HSPF2:7.80 9. Floor Types Insulation Area 16. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 2796.00 ft 2 a. Pro ane-rankless p Ca 1 gallons p b. Floor Over Other Space R= 0.0 1626.00 ft2 EF: 0.820 c. N/A R= ft2 b. Conservation features None 17. Credits Pstat Glass/Floor Area: 0.142 Total Proposed Modified Loads: 104.06 Total Baseline Loads: 111.29 PASS NOTE: Proposed residence must have annual total normalized Modified Loads that are less than or equal to 95 percent of the annual total loads of the standard reference design in order to comply. I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this -VIAE STaIc� Code. O� calculation indicates compliance Florida Energy Code. 01 ti a O� PREPARED BY: with the Before construction is completed;,,, this building will be inspected for Ix DATE: 4/8/2025 compliance with Section 553.908 a a o Florida Statutes. { I hereby certify that this b i ing, as si ed, is i o lance with the Florida Energy7d OU W6 OWNER/AGENT: // BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Default duct leakage does not require a Duct Leakage Test Report. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). 4/8/2025 1:46:22 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 FORM R405-2023 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? Atlantic Beach Dr,Atlantic Beach,FL, New (From Plans) Detached 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (ft2) 7. Windows** Description a. U -Factor: Dbl, U=0.40 SHGC: SHGC=0.25 b. U -Factor: N/A SHGC: c. U -Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. Floor Over Other Space R= 0.0 c. N/A R= 4 No 4422 0 Area 625.92 ft2 ft2 ft2 6.546 ft 0.250 Area N/A ft2 Area 2796.00 ft2 1626.00 ft2 ft2 10. Wall Types(4166.8 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=5.0 2073.00 ft2 b. Frame - Wood, Exterior R=19.0 1634.40 ft2 c. Frame - Wood, Adjacent R=19.0 459.38 ft2 d. N/A 11. Ceiling Types(2796.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2796.00 ft2 b. N/A c. N/A 12. Roof(Metal, Unvent) Deck R=20.0 3237 ft2 13. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: 1st Floor 6 363 b. Sup: Attic, Ret: Attic, AH: 2nd Floor 6 211 C. 14. Cooling Systems kBtu/hr Efficiency a. Central Unit 34.8 SEER2:15.20 b. Central Unit 23.2 SEER2:15.20 15. Heating Systems a. Electric Heat Pump b. Electric Heat Pump 16. Hot Water Systems a. PropaneTankless b. Conservation features 17. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the ab a energy saving features which will be installed (or exceeded) in this home before final iqs ection. Ot ise, a new EP isplay Card will be completed based on installed Cod ' mpliant f re� Builder Signature. Date: 6 Address of New Home: Atlantic Beach Dr City/FL Zip: Atlantic Beach,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. kBtu/hr Efficiency 33.8 HSPF2:7.80 22.4 HSPF2:7.80 Cap: 1 gallons EF: 0.820 None Pstat 011-T14E S7-4r��.n G'OI) - 4/8/2025 1:46:22 PM EnergyGauge® USA 8.0.00 - FlaRes2023 FBC 8th Edition (2023) Compliant Software Page 1 of 1