1841 ATLANTIC BEACH DR SOLR25-0004 Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: BRZEZICKI GRZEGORZ 1841 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: A1A SOLAR CONTRACTING INC 10418 NEW BERLIN 223 JACKSONVILLE FL 32226 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1535 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1841 ATLANTIC BEACH DR ELECTRICAL SOLAR PANEL ELECTRIC FOR SOLAR SYSTEM $67127.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.03 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/16/2025 PERMIT NUMBER SOLR25-0004 ISSUED: 10/16/2025 EXPIRES: 4/14/2026 ELECTRICAL SOLAR PANEL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $139.03 2 of 2Issued Date: 10/16/2025 PERMIT NUMBER SOLR25-0004 ISSUED: 10/16/2025 EXPIRES: 4/14/2026 ELECTRICAL SOLAR PANEL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 View Communication From: DoNotReply@PowerClerk.com To: permits@a1asolar.com;as_1841atlantic_jeai@permitflowteam.com;cliff.little@a1asolar.com;virginia.jada@a1asolar.com Cc: g.brzezicki@yahoo.com Subject: JEA Interconnection Application For Project JEA-17112 - BRZEZICKI - Is Approved. JEA PROJECT #: JEA-17112 STATUS: Interconnection Application approved by JEA CUSTOMER NAME: GRZEGORZ BRZEZICKI PROJECT ADDRESS: 1841 Atlantic Beach Drive   Atlantic Beach, FL 32233 PROJECT COST: $67,127.00 INSTALLER: A1A SOLAR CONTRACTING, INC PV PANEL QUANTITY: Inverter: 1 x Sol-Ark 15.0 kW (Model Limitless 15K-LV {240V} [SI1])     PV Module Array: 21 x JA Solar Holding 440W (Model JAM54D41-440/MB)     PV Module Array: 18 x JA Solar Holding 440W (Model JAM54D41-440/MB)     PV Module Array: 4 x JA Solar Holding 440W (Model JAM54D41-440/MB)     Battery: 2 x Renon Power Technology R-XL015031 BATTERY STORAGE:  COMMENTS:  ***SIGNAGE REMINDER*** SIGNAGE REQUIREMENTS: If the PV and/or Battery disconnect switch is not visibly/reasonably near the JEA electric meter then a sign must be installed at the JEA electric meter location that is: red, approximately JEA has introduced a new Solar Concierge Program for customers to learn more about solar, run calculations, and find contractors in its new Solar Unified Network-SUN. Click SUN to learn more about joining the network. 22/09/2025, 08:29 View Communication https://jeadistgen.powerclerk.com/MvcProjects/ViewCommunication?ProgramId=MPRWRKVQXRX8&ProjectId=YKDF3CB2MC46&CommunicationId=…1/2 6"x6", 3/8" white lettering, made of metal, hard plastic, or weatherproof vinyl. This sign must indicate where the disconnect is located externally and accessible on the building. The description may be text or a visual depiction. ***DO NOT LEAVE SYSTEM ENERGIZED PRIOR TO PTO***  Do not leave the generation system energized beyond commissioning and, if energy storage is included, the energy storage system. Do not export energy to JEA before JEA installs the new solar meter. The current meter may reverse register direction and activate anti-theft signals to JEA. NEXT STEP: Contractor submits active Electric Permit # From Local Building Department into PowerClerk. JEA - System Analysis  www.jea.com 22/09/2025, 08:29 View Communication https://jeadistgen.powerclerk.com/MvcProjects/ViewCommunication?ProgramId=MPRWRKVQXRX8&ProjectId=YKDF3CB2MC46&CommunicationId=…2/2 Name PhonePROPERTY OWNER JOB ADDRESS PROJECT VALUE $ NEW SERVICE: amps # of Meters State Certification # ZipStateCityAddress PhoneNameELECTRIC COMPANY NOTICE: Permit becomes expired if work does not commence within a six month period or work is suspended or abandoned for six months. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. License Holder FOR INTERNAL OFFICE USE ONLY PERMIT # ____________________ **ALL information required to process "In lieu of signed, sworn and notarized signatures of the property owner, agent and/or contractor, and under penalties of perjury, I declare that I have read and examined the foregoing application and that the facts stated in it are true and correct." JEA INFORMATION REQUIRED ON ALL PERMITS:AMPS Overhead Underground Underground up Pole Residential (Main) Service: amps CT Service151-200 amps101-150 amps0-100 amps Commercial (Main) Service: amps # of Unit Meters151-200 amps101-150 amps0-100 amps Multi-Famil (Main) Service: Conductor Type amps Conductor Size TEMPORARY POLE:amps SERVICE UPGRADE:ampsamps CT Service ampsamps CT Service200 amps150 amps100 amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.): ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS, ACCESSORY STRUCTURES, ETC: 0-30 ampsOutlets/Switches:31-100 amps 101-200 amps 101-200 amps31-100 amps0-30 ampsAppliances: 61-100 amps0-60 ampsA/C Circuits: kw# circuits @Heat Circuits:# of Lighting Outlets, Including Fixtures: SignSwimming PoolGenerator volts/ampsQuantity FIRE ALARM SYSTEM (Requires 1 set of digital plans): Safety InspectionReplace Burnt/Damaged Meter Can REPAIRS/MISCELLANEOUS: Panel Change OH to UG Other: ELECTRICAL PERMIT APPLICATION City of Atlantic Beach Building Division 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904)247-5826 Email: Building-Dept@coab.us OTHER ELECTRICAL PROJECTS 151-200 amps101-150 amps0-100 amps VOLTS PHASE Whole house (ATS) or Stand alone SIGNATURE OF CONTRACTOR PRINT OR TYPE NAME OF CONTRACTOR DATE Electric Permit Application 07.03.2025 Email GRZEGORZ BRZEZICKI (216) 258-9341 1841 ATLANTIC BEACH DRATLANTIC BEACH, FL 32233 $67,127 EC13001175 32226FL Jacksonville 10418 New Berlin Road Unit 223 (904) 665-6000Jacksonville Electric Authority CHRISTIAN MASARIK 200 N/A N/A N/A N/A N/A N/AN/A N/A To install a grid-tied rooftop solar PV system with Sol-Ark 15KW & RENON 16kWh integrated battery system 240 1 08-26-2025 CHRISTIAN MASARIK permits@a1asolar.com A1A SOLAR CONTRACTING, INC Doc # 2025216551, OR BK 21620 Page 1732, Number Pages: 1, Recorded 09/17/2025 08:45 AM, JODY PHILLIPS CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 Permit No. State of FLORIDA To whom it may concern: NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE) Tax Folio No. 169505 1535 County of DUVAL The undersigned hereby informs you that Improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes, the following Information is stated in this NOTICE OFCOMMENCEMENT. Legal description of property being improved: 06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 Address of propertybeing improved: 1841 ATLANTIC BEACH DR Atlantic Beach FL 32233 General description of improvements: Residential roof-mounted solar pv system and battery installation Owner GRZEGORZ BRZEZICKI Address 1841 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 Owner's interest in site of the improvement OWner Fee Simple Titleholder (if other than owner) Name Address Contractor A1A SOLAR CONTRACTING, INC Address 10418 New Berlin Road Unit 223, Jacksonville, FL 32226 Phone No, (904) 468-7861 Surety (if any) Address Phone No. Fax No. _ Amount of bond $ Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No.Fax No. Name of person within the State of Florida, other than himself or herself, designated by owner upon whom notices or other documents may be served: Name Address Phone No.Fax No. In addition to himself or herself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06 (2) (b), Florida Statutes. (Fill in at Owner's option). Name Address Phone No.Fax No. Expiration date of Notice of Commencement (the expiration date is one (1) year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY h OWNER Signed:Before me this 2b day of Auaust County of Duval, Stale of Florida, has personally appearedCarzenorz Brzezicki DATE 8/29125 in the herein byhimself/ herself and affirms that all statements and deciarations herein are true and accurate Notary Publle at Large. State of ora County of Duval My commission expires: 17/11207aMy conPersonally KnownProduced Identification D: B622-291-80-3350 CALI COLINGWOOONotary PublicState of FloridaComm# HH603937Comm HMS957Expires7/2/2025 Name PhonePROPERTY OWNER JOB ADDRESS PROJECT VALUE $ NEW SERVICE: amps # of Meters State Certification # ZipStateCityAddress PhoneNameELECTRIC COMPANY NOTICE: Permit becomes expired if work does not commence within a six month period or work is suspended or abandoned for six months. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. License Holder FOR INTERNAL OFFICE USE ONLY PERMIT # ____________________ **ALL information required to process "In lieu of signed, sworn and notarized signatures of the property owner, agent and/or contractor, and under penalties of perjury, I declare that I have read and examined the foregoing application and that the facts stated in it are true and correct." JEA INFORMATION REQUIRED ON ALL PERMITS:AMPS Overhead Underground Underground up Pole Residential (Main) Service: amps CT Service151-200 amps101-150 amps0-100 amps Commercial (Main) Service: amps # of Unit Meters151-200 amps101-150 amps0-100 amps Multi-Famil (Main) Service: Conductor Type amps Conductor Size TEMPORARY POLE:amps SERVICE UPGRADE:ampsamps CT Service ampsamps CT Service200 amps150 amps100 amps NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.): ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS, ACCESSORY STRUCTURES, ETC: 0-30 ampsOutlets/Switches:31-100 amps 101-200 amps 101-200 amps31-100 amps0-30 ampsAppliances: 61-100 amps0-60 ampsA/C Circuits: kw# circuits @Heat Circuits:# of Lighting Outlets, Including Fixtures: SignSwimming PoolGenerator volts/ampsQuantity FIRE ALARM SYSTEM (Requires 1 set of digital plans): Safety InspectionReplace Burnt/Damaged Meter Can REPAIRS/MISCELLANEOUS: Panel Change OH to UG Other: ELECTRICAL PERMIT APPLICATION City of Atlantic Beach Building Division 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904)247-5826 Email: Building-Dept@coab.us OTHER ELECTRICAL PROJECTS 151-200 amps101-150 amps0-100 amps VOLTS PHASE Whole house (ATS) or Stand alone SIGNATURE OF CONTRACTOR PRINT OR TYPE NAME OF CONTRACTOR DATE Electric Permit Application 07.03.2025 Email GRZEGORZ BRZEZICKI (216) 258-9341 1841 ATLANTIC BEACH DRATLANTIC BEACH, FL 32233 $67,127 EC13001175 32226FL Jacksonville 10418 New Berlin Road Unit 223 (904) 665-6000Jacksonville Electric Authority CHRISTIAN MASARIK 200 N/A N/A N/A N/A N/A N/AN/A N/A To install a grid-tied rooftop solar PV system with Sol-Ark 15KW & RENON 16kWh integrated battery system 240 1 08-26-2025 CHRISTIAN MASARIK permits@a1asolar.com Home Green Home, Inc. 75081 Brookwood Drive Yulee, FL 32097 August 28, 2025 Mr. J. Peter Wilking A1A Solar, Inc. 10418 New Berlin Road Suite 223 Jacksonville, FL 32226 RE: Roof Bearing Capacity for the Brzezicki Residence – 1841 Atlantic Beach Drive, Atlantic Beach, FL 32081 Dear Mr. Wilking, Per your request, I have prepared the following letter and calculations for the Brzezicki Residence in Atlantic Beach, FL. The analysis was done using ASCE 7-22 standards. The ASCE 7-22 ultimate windspeed for the location of the dwelling is 129 mph. My analysis used a windspeed of 130 mph with exposure D to determine the maximum rail spans. Based on this report, the minimum span for XR100 rail in these conditions is 51” and the proposed maximum span for this installation is 48” which conforms to the standard. The dwelling was built in 2019 with a roof support system consisting of 2”x4” Southern Pine trusses, spaced 24” O.C. with a maximum span of 20 ft. Asphalt shingle roofing and ESB cover the trusses. The design dead load (10 PSF) + live load (30 PSF) is 40 PSF, which translates to 1,600 lbs/truss. The proposed PV system will add an additional 2.5 PSF or 50 lbs/truss, for a total load of 1,650 lbs/truss. The roof structure will be able to withstand the additional weight from the PV system. Please let me know if you have any questions or need additional information. Sincerely, Robert J. Montanaro, PE