299 Atlantic Blvd MECH25-0011 PermitOWNER:ADDRESS:CITY:STATE:ZIP: SOUTHCOAST CAPITAL PRTNSHIP LTD 241 ATLANTIC BLVD JACKSONVILLE FL 32202-5018 COMPANY:ADDRESS:CITY:STATE:ZIP: ANGLER HEATING & AIR INC.2071 EMERSON ST 12 JACKSONVILLE FL 32207 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172531 0000 ATLANTIC BEACH TERRACE JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 299 ATLANTIC BLVD MECHANICAL COMMERCIAL SEPARATE PLANS HVAC COMMERCIAL HOODS $5000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT COMMERCIAL HOOD INSTALLATION 455-0000-322-1000 0 $30.00 FIRE DEPT REVIEW 455-0000-208-0800 0 $125.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/7/2025 PERMIT NUMBER MECH25-0011 ISSUED: 11/7/2025 EXPIRES: 5/6/2026 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $214.00 2 of 2Issued Date: 11/7/2025 PERMIT NUMBER MECH25-0011 ISSUED: 11/7/2025 EXPIRES: 5/6/2026 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD DESCRIPTION ACCOUNT QTY PAID PermitTRAK $214.00 MECH25-0011 Address: 299 ATLANTIC BLVD APN: 172531 0000 $214.00 FIRE DEPARTMENT FEE $125.00 FIRE DEPT REVIEW 455-0000-208-0800 0 $125.00 MECHANICAL $85.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 COMMERCIAL HOOD INSTALLATION 455-0000-322-1000 0 $30.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R32587 $214.00 Printed: Friday, November 7, 2025 4:30 PM Date Paid: Friday, November 07, 2025 Paid By: ANGLER HEATING & AIR INC. Pay Method: CREDIT CARD 4 1 of 1 Cashier: SA Cash Register Receipt City of Atlantic Beach Receipt Number R32587 Jacksonville Office REGION 65 PHONE: (904) 463 - 6242 EMAIL: reg65@captiveaire.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#8323822 1 3624 ES-VHB ECON-AIR 5' 0" 700 DEG II N/A 150 750 4"10"750 1375 -0.113" 430 SS 100% ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 0 NO 141 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT 5' 0"NOM./5' 0.00"OD. 36" § 30"30" 18" ∅10" PLAN VIEW - HOOD #1 5' 0.00" LONG 3624ES-VHB 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. EQUIPMENT BY OTHERS. 80" 24" NOM. 36" *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. SECTION VIEW - MODEL 3624ES-VHB HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 1 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 EXHAUST FAN INFORMATION - JOB#8323822 1 1 DU33HFA CAPTIVEAIRE 700 0.500 1270 TEAO-ECM 0.333 0.1360 1 115 4.3 347 FPM 65 11.2 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS) SONES CURB ASSEMBLIES 1 # 1 50 LBS CURB 19.500"W X 19.500"L X 24.000"H 0.375:12.000 PITCH ALONG LENGTH, RIGHT VENTED 16 GAUGE. NO ON FAN WEIGHT ITEM SIZE REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 2 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 FAN OPTIONS FAN UNIT NO TAG QTY DESCRIPTION 1 1 FAN BASE CERAMIC SEAL - DU/DR30/33HFA - INSTALLED AT PLANT - FOR GREASE DUCTS 1 ECM WIRING PACKAGE - EXHAUST - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -MSC- (TELCO), CCW ROTATION 1 MIAMI DADE CERTIFICATION - NOA-1 ALUMINUM UPBLAST 1 SCR-11 BIRD SCREEN 1 2 YEAR PARTS WARRANTY MIAMI-DADE NOA1 ALUMINUM UP-BLAST FANS INSTALLATION FASTENER TYPES FAN TO CURB WOOD (SG = 0.42 MIN.)STEEL (12 GAUGE MIN.) CONCRETE (2500 PSI MIN. CRACKED CONCRETE) FASTENER 5/16"-18 X 2" SELF DRILLING SCREW (ELCO DRIL-FLEX OR BETTER) 3/8" DIA. ZINC PLATED LAG BOLT 1/4"-14 DRIL-FLEX SELF DRILLING SCREW 3/8" DIA. SS HILTI KWIK BOLT TZ EXPANSION ANCHOR MINIMUM THREAD PENETRATION N/A 2-1/2"12 GAUGE 2" MINIMUM EDGE DISTANCE N/A 1-1/2"3/8"3" MINIMUM END DISTANCE N/A 2-5/8"3/8"3" MINIMUM SPACING N/A 1-1/2"3/4"5-1/2" INSTALLATION FASTENER QTY CURB TO FAN (ROOF) CURB TO FAN (WALL) WOOD (ROOF)WOOD (WALL)STEEL (ROOF) STEEL (WALL) CONCRETE (ROOF) CONCRETE (WALL) FAN MODEL PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTAL PER SIDE TOTA L DU33 3 12 3 12 3 12 3 12 4 16 4 16 3 12 3 12 DESIGN PRESSURE: +150.0 / -150.0 PSF. LARGE MISSILE IMPACT RESISTANT. GENERAL NOTES: 1. THIS APPROVAL IS FOR THE STRUCTURAL CAPACITY AND IMPACT RATING OF THE EXTERIOR HOUSING ONLY; IT DOES NOT INCLUDE ANY INTERIOR MECHANISM OR ELECTRICAL PART. 2. THESE FANS HAVE NOT BEEN WIND TESTED FOR WIND DRIVEN RAIN TEST PER FLORIDA BUILDING CODE, TAS100 (A)-95. 3. TESTED IN ACCORDANCE TO FLORIDA BUILDING CODE TEST PROTOCOL TAS201, TAS202, TAS203. 4. TESTED FOR AREAS INCLUDING HIGH VELOCITY HURRICANE ZONES. 5. TESTED UNDER MIAMI-DADE COUNTY NOTIFICATION NUMBER ATI-08033. CURB MATERIAL: 20" HIGH & LESS = 20 GA. STEEL. ABOVE 20" THRU 42" = 16 GA. STEEL. 1 2 INSTALLATION INSTRUCTIONS: 1. SECURE LID TO FAN USING (8) 1/4"-14 X 1" ZINC PLATED STEEL SELF DRILLING SHEET METAL SCREWS WITH RUBBER WASHER SPACED EVENLY AROUND LID. 2. SECURE FAN BASE TO CURB USING 1/4"-14 X 2" GALVANIZED SELF DRILLING SCREWS (A307 OR BETTER) THROUGH PRE-PUNCHED HOLES IN THE FAN BASE. (SEE TABLE BELOW FOR QTY). 3. SECURE CURB TO ROOF OR WALL BY DRILLING 1/4" DIA PILOT HOLES IN THE CURB FLANGE AT LOCATIONS SHOWN IN THE DIAGRAM. SEE TABLE BELOW FOR FASTENER TYPE. USE TABLE BELOW FOR FASTENER QTY. 3 FULLY WELDED CURB CORNERS (ABOVE 20" HEIGHT). MAX CURB HEIGHT 42". MIN END DISTANCE. MIN SPACING. MIN EDGE DISTANCE. MIAMI-DADE COUNTY - CURB ROOF INSTALLATION GUIDE ROOF OPENING. MIN EDGE DISTANCE. MIN END DISTANCE. MIN SPACING. ROOF SUBSTRATE. CURB. WOOD: SG =0.42 MIN. CONCRETE: 2500 PSI MIN. STEEL: 12 GAUGE MIN. CURB. WOOD: 4 X JOIST MIN SG = 0.42 MIN. STEEL: 12 GAUGE TRUSS MIN. ROOF OPENING. A DETAIL A SEE SPECIFIC FAN MODEL FASTENER TABLES FOR FASTENER TYPE AND QTY. WASHER (STEEL ZINC PLATED) FOR SCREW SIZES 3/8" TYP. CURB. 1/4" PILOT HOLE. WALL SUBSTRATE. 1/4" PILOT HOLE. ROOF OPENING. A DETAIL A CURB. MIN EDGE DISTANCE. STEEL: 12 GAUGE TRUSS MIN. WOOD: 4X JOIST MIN SG = 0.42. STEEL: 12 GAUGE MIN. CONCRETE: 2500 PSI MIN. WOOD: SG = 0.42 MIN. WALL SUBSTRATE: FASTENER TYPE AND QTY. FASTENER TABLES FOR SEE SPECIFIC FAN MODEL FOR SCREW SIZE 3/8" TYP. WASHER (STEEL ZINC PLATED) ROOF OPENING. MIN SPACING. MIN END DISTANCE. MIN EDGE DISTANCE. WALL CURB INSTALLATION GUIDE MIAMI-DADE COUNTY - REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 3 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 19" 21" 25 1/2" 12 1/8" 2" 18 1/2" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 25 1/2" 21" - NEMA 3R SAFETY DISCONNECT SWITCH. DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS). 25 1/4" - UL705 FAN #1 DU33HFA - EXHAUST FAN OPTIONS - FAN BASE CERAMIC SEAL - DU/DR30/33HFA - INSTALLED AT PLANT - FOR GREASE DUCTS. - ECM WIRING PACKAGE - EXHAUST - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -MSC- (TELCO), CCW ROTATION. - MIAMI DADE CERTIFICATION - NOA-1 ALUMINUM UPBLAST. - SCR-11 BIRD SCREEN. - 2 YEAR PARTS WARRANTY. 3" FLANGE. 19" 19" ROOF OPENING DIMENSIONS. 16 GAUGE CONSTRUCTION. STEEL 24" 19 1/2" 19 1/2" VENTED CURB. EXAMPLE: 7/12 PITCH = 30° SLOPE. PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH: 3/8" 2° 12" REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 4 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 GREASE DUCT & CHIMNEY SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. § CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED APPROVED WITH NO EXCEPTION TAKEN REVISE AND RESUBMIT SIGNATURE YOUR TITLE DATE LISTED GREASE DUCT. EXHAUST FAN. § HIGH TEMP GASKET IS USED TO SEAL THE FAN TO THE TRANSITION PLATE. VENTED CURB ROOF TERMINATION. THE INNER DUCT IS FULLY WELDED TO THE TRANSITION PLATE, ALL WELDS ARE DYE TESTED. SECURED TO THE CURB BY OTHER. *NOTE: UL 762 INSTALL. REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 5 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 MECHANICAL PERMIT APPLICATION City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904)247-5826 Email: Building-Dept@coab.us JOB ADDRESS Q'79 M*/ah-'ic ,G'l/J c ; ve -x i /4rlan.. e BQaoh- -fl 3,zaS 3 q NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # (REQUIRED) FOR INTERNAL OFFICE USE ONLY PERMIT # •BALL information required to process PROJECT VALUE $~5,doO 00 q Air Handling Equipment Only q Condenser Only q Air Handling Unit & Condenser Air Conditioning: Unit Quantity Tons per Unit BTU's per Unit Heat: Duct Systems: Unit Quantity Total CFM Seer Rating (REQUIRED) q REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI #(REQUIRED) q Air Handling Equipment Only q Condenser Only q Air Handling Unit & Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTU's per Unit Duct Systems: Total CFM Seer Rating (REQUIRED) q FIRE PREVENTION Fire Sprinkler System Fire Standpipe Underground Fire Main Fire Hose Cabinets Commercial Hoods Fire Suppression Systems q ALL OTHER GAS PIPING Quantity of Outlets # Vented Wall Furnaces # Water Heaters Fireplace q Other: Quantity Quantity Value Quantity Quantity l- £33(gsr 2- Vt&tf (Requires 1 set of digital plans) Quantity d1O(Requires 1 set of digital plans) (Requires 1 set of digital plans) (Requires 1 set of digital plans) (Requires 1 set of digital plans) (Requires 1 set of digital plans) q MISCELLANEOUS Generator Gas Tanks Pre-fabricated Fireplace Solar Collection Systems NOTICE: Permit becomes expired if work does not commence within a six month period or work is suspended or abandoned for six months. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. PROPERTY OWNER Name q MECHANICAL COMPANY Name /4y/e' m414417 : i t c Address (2t7/ EMEKsOta. £4- S.,' L City 'JeGCahVI/CQ License Holder J3'S 106 ~f/O{-' State Certification # L: .'*?Qc/ 7o6i 3 Email Phone Phone 9Dy- &83 9wt State ft Zip 322 cl 'N'dq~ f - Lbwl "In lieu of signed, sworn and notarized signatures of the property owner, agent and/or contractor, and under penalties of perjury, I dgclare t have read and examined the foregoing application and that the facts stated in it are true and correct." l tngt,O t ',cM- SIGNATURE OF CONTRACTOR PRINT OR TYPE NAME OF CONTRACTOR S DATE Mechanical Permit Application 02.25.2 025 MECH25-0011 Jacksonville Office REGION 65 PHONE: (904) 463 - 6242 EMAIL: reg65@captiveaire.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#8323822 1 3624 ES-VHB ECON-AIR 5' 0" 700 DEG II N/A 150 750 4"10"750 1375 -0.113" 430 SS 100% ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 0 NO 141 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT 5' 0"NOM./5' 0.00"OD. 36" § 30"30" 18" ∅10" PLAN VIEW - HOOD #1 5' 0.00" LONG 3624ES-VHB 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) SEE HOOD TABLE. § EXHAUST RISER. HANGING ANGLE. EQUIPMENT BY OTHERS. 80" 24" NOM. 36" *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. SECTION VIEW - MODEL 3624ES-VHB HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 1 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 EXHAUST FAN INFORMATION - JOB#8323822 1 1 DU33HFA CAPTIVEAIRE 700 0.500 1270 TEAO-ECM 0.333 0.1360 1 115 4.3 347 FPM 65 11.2 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS) SONES CURB ASSEMBLIES 1 # 1 50 LBS CURB 19.500"W X 19.500"L X 24.000"H 0.375:12.000 PITCH ALONG LENGTH, RIGHT VENTED 16 GAUGE. NO ON FAN WEIGHT ITEM SIZE REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 2 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 FAN OPTIONS FAN UNIT NO TAG QTY DESCRIPTION 1 1 FAN BASE CERAMIC SEAL - DU/DR30/33HFA - INSTALLED AT PLANT - FOR GREASE DUCTS 1 ECM WIRING PACKAGE - EXHAUST - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -MSC- (TELCO), CCW ROTATION 1 MIAMI DADE CERTIFICATION - NOA-1 ALUMINUM UPBLAST 1 SCR-11 BIRD SCREEN 1 2 YEAR PARTS WARRANTY MIAMI-DADE NOA1 ALUMINUM UP-BLAST FANS INSTALLATION FASTENER TYPES FAN TO CURB WOOD (SG = 0.42 MIN.)STEEL (12 GAUGE MIN.) CONCRETE (2500 PSI MIN. CRACKED CONCRETE) FASTENER 5/16"-18 X 2" SELF DRILLING SCREW (ELCO DRIL-FLEX OR BETTER) 3/8" DIA. ZINC PLATED LAG BOLT 1/4"-14 DRIL-FLEX SELF DRILLING SCREW 3/8" DIA. SS HILTI KWIK BOLT TZ EXPANSION ANCHOR MINIMUM THREAD PENETRATION N/A 2-1/2"12 GAUGE 2" MINIMUM EDGE DISTANCE N/A 1-1/2"3/8"3" MINIMUM END DISTANCE N/A 2-5/8"3/8"3" MINIMUM SPACING N/A 1-1/2"3/4"5-1/2" INSTALLATION FASTENER QTY CURB TO FAN (ROOF) CURB TO FAN (WALL) WOOD (ROOF)WOOD (WALL)STEEL (ROOF) STEEL (WALL) CONCRETE (ROOF) CONCRETE (WALL) FAN MODEL PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTA L PER SIDE TOTAL PER SIDE TOTA L DU33 3 12 3 12 3 12 3 12 4 16 4 16 3 12 3 12 DESIGN PRESSURE: +150.0 / -150.0 PSF. LARGE MISSILE IMPACT RESISTANT. GENERAL NOTES: 1. THIS APPROVAL IS FOR THE STRUCTURAL CAPACITY AND IMPACT RATING OF THE EXTERIOR HOUSING ONLY; IT DOES NOT INCLUDE ANY INTERIOR MECHANISM OR ELECTRICAL PART. 2. THESE FANS HAVE NOT BEEN WIND TESTED FOR WIND DRIVEN RAIN TEST PER FLORIDA BUILDING CODE, TAS100 (A)-95. 3. TESTED IN ACCORDANCE TO FLORIDA BUILDING CODE TEST PROTOCOL TAS201, TAS202, TAS203. 4. TESTED FOR AREAS INCLUDING HIGH VELOCITY HURRICANE ZONES. 5. TESTED UNDER MIAMI-DADE COUNTY NOTIFICATION NUMBER ATI-08033. CURB MATERIAL: 20" HIGH & LESS = 20 GA. STEEL. ABOVE 20" THRU 42" = 16 GA. STEEL. 1 2 INSTALLATION INSTRUCTIONS: 1. SECURE LID TO FAN USING (8) 1/4"-14 X 1" ZINC PLATED STEEL SELF DRILLING SHEET METAL SCREWS WITH RUBBER WASHER SPACED EVENLY AROUND LID. 2. SECURE FAN BASE TO CURB USING 1/4"-14 X 2" GALVANIZED SELF DRILLING SCREWS (A307 OR BETTER) THROUGH PRE-PUNCHED HOLES IN THE FAN BASE. (SEE TABLE BELOW FOR QTY). 3. SECURE CURB TO ROOF OR WALL BY DRILLING 1/4" DIA PILOT HOLES IN THE CURB FLANGE AT LOCATIONS SHOWN IN THE DIAGRAM. SEE TABLE BELOW FOR FASTENER TYPE. USE TABLE BELOW FOR FASTENER QTY. 3 FULLY WELDED CURB CORNERS (ABOVE 20" HEIGHT). MAX CURB HEIGHT 42". MIN END DISTANCE. MIN SPACING. MIN EDGE DISTANCE. MIAMI-DADE COUNTY - CURB ROOF INSTALLATION GUIDE ROOF OPENING. MIN EDGE DISTANCE. MIN END DISTANCE. MIN SPACING. ROOF SUBSTRATE. CURB. WOOD: SG =0.42 MIN. CONCRETE: 2500 PSI MIN. STEEL: 12 GAUGE MIN. CURB. WOOD: 4 X JOIST MIN SG = 0.42 MIN. STEEL: 12 GAUGE TRUSS MIN. ROOF OPENING. A DETAIL A SEE SPECIFIC FAN MODEL FASTENER TABLES FOR FASTENER TYPE AND QTY. WASHER (STEEL ZINC PLATED) FOR SCREW SIZES 3/8" TYP. CURB. 1/4" PILOT HOLE. WALL SUBSTRATE. 1/4" PILOT HOLE. ROOF OPENING. A DETAIL A CURB. MIN EDGE DISTANCE. STEEL: 12 GAUGE TRUSS MIN. WOOD: 4X JOIST MIN SG = 0.42. STEEL: 12 GAUGE MIN. CONCRETE: 2500 PSI MIN. WOOD: SG = 0.42 MIN. WALL SUBSTRATE: FASTENER TYPE AND QTY. FASTENER TABLES FOR SEE SPECIFIC FAN MODEL FOR SCREW SIZE 3/8" TYP. WASHER (STEEL ZINC PLATED) ROOF OPENING. MIN SPACING. MIN END DISTANCE. MIN EDGE DISTANCE. WALL CURB INSTALLATION GUIDE MIAMI-DADE COUNTY - REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 3 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 - VARIABLE SPEED CONTROL. - THERMAL OVERLOAD PROTECTION (SINGLE PHASE). - HIGH HEAT OPERATION 300°F (149°C). EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. NORMAL TEMPERATURE TEST 19" 21" 25 1/2" 12 1/8" 2" 18 1/2" - INTERNAL WIRING. - ROOF MOUNTED FANS. - RESTAURANT MODEL. FEATURES: - DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS). TOP VIEW 25 1/2" 21" - NEMA 3R SAFETY DISCONNECT SWITCH. DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS). 25 1/4" - UL705 FAN #1 DU33HFA - EXHAUST FAN OPTIONS - FAN BASE CERAMIC SEAL - DU/DR30/33HFA - INSTALLED AT PLANT - FOR GREASE DUCTS. - ECM WIRING PACKAGE - EXHAUST - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL -MSC- (TELCO), CCW ROTATION. - MIAMI DADE CERTIFICATION - NOA-1 ALUMINUM UPBLAST. - SCR-11 BIRD SCREEN. - 2 YEAR PARTS WARRANTY. 3" FLANGE. 19" 19" ROOF OPENING DIMENSIONS. 16 GAUGE CONSTRUCTION. STEEL 24" 19 1/2" 19 1/2" VENTED CURB. EXAMPLE: 7/12 PITCH = 30° SLOPE. PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH: 3/8" 2° 12" REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 4 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 GREASE DUCT & CHIMNEY SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. § CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED APPROVED WITH NO EXCEPTION TAKEN REVISE AND RESUBMIT SIGNATURE YOUR TITLE DATE LISTED GREASE DUCT. EXHAUST FAN. § HIGH TEMP GASKET IS USED TO SEAL THE FAN TO THE TRANSITION PLATE. VENTED CURB ROOF TERMINATION. THE INNER DUCT IS FULLY WELDED TO THE TRANSITION PLATE, ALL WELDS ARE DYE TESTED. SECURED TO THE CURB BY OTHER. *NOTE: UL 762 INSTALL. REV. DWG # DATE LOCATION JOB DRAWN BY SCALE JOB # ACCORDANCE No. 96 BUILT NFPA WITH IN SLI DTE R C US 5 11/4/2025 JACKSONVILLE, FL, Angie's AB 3/8" = 1'-0" reg65 8323822 MECHANICAL PERMIT APPLICATION City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904)247-5826 Email: Building-Dept@coab.us JOB ADDRESS Q'79 M*/ah-'ic ,G'l/J c ; ve -x i /4rlan.. e BQaoh- -fl 3,zaS 3 q NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI # (REQUIRED) FOR INTERNAL OFFICE USE ONLY PERMIT # •BALL information required to process PROJECT VALUE $~5,doO 00 q Air Handling Equipment Only q Condenser Only q Air Handling Unit & Condenser Air Conditioning: Unit Quantity Tons per Unit BTU's per Unit Heat: Duct Systems: Unit Quantity Total CFM Seer Rating (REQUIRED) q REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI #(REQUIRED) q Air Handling Equipment Only q Condenser Only q Air Handling Unit & Condenser Air Conditioning: Unit Quantity Tons per Unit Heat: Unit Quantity BTU's per Unit Duct Systems: Total CFM Seer Rating (REQUIRED) q FIRE PREVENTION Fire Sprinkler System Fire Standpipe Underground Fire Main Fire Hose Cabinets Commercial Hoods Fire Suppression Systems q ALL OTHER GAS PIPING Quantity of Outlets # Vented Wall Furnaces # Water Heaters Fireplace q Other: Quantity Quantity Value Quantity Quantity l- £33(gsr 2- Vt&tf (Requires 1 set of digital plans) Quantity d1O(Requires 1 set of digital plans) (Requires 1 set of digital plans) (Requires 1 set of digital plans) (Requires 1 set of digital plans) (Requires 1 set of digital plans) q MISCELLANEOUS Generator Gas Tanks Pre-fabricated Fireplace Solar Collection Systems NOTICE: Permit becomes expired if work does not commence within a six month period or work is suspended or abandoned for six months. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. PROPERTY OWNER Name q MECHANICAL COMPANY Name /4y/e' m414417 : i t c Address (2t7/ EMEKsOta. £4- S.,' L City 'JeGCahVI/CQ License Holder J3'S 106 ~f/O{-' State Certification # L: .'*?Qc/ 7o6i 3 Email Phone Phone 9Dy- &83 9wt State ft Zip 322 cl 'N'dq~ f - Lbwl "In lieu of signed, sworn and notarized signatures of the property owner, agent and/or contractor, and under penalties of perjury, I dgclare t have read and examined the foregoing application and that the facts stated in it are true and correct." l tngt,O t ',cM- SIGNATURE OF CONTRACTOR PRINT OR TYPE NAME OF CONTRACTOR S DATE Mechanical Permit Application 02.25.2 025 MECH25-0011