HomeMy WebLinkAbout3-17-26 CDB Adopted MinutesMINUTES
Community Development Board (CDB) Meeting
Tuesday, March 17, 2026 - 6:00 PM
City Hall, Commission Chamber
800 Seminole Road, Atlantic Beach, FL 32233
Present: Kirk Hansen, Chair
Gregory (Greg) Beliles, Member
Ellen Golombek, Vice Chair
Jeff Haynie, Member
Doug Moody, First Alternate Member
Rick Ferrin, Member
Absent:
Richard Arthur, Member
Also Present: Valerie Jones, Recording Clerk
Payton Jamieson, Principal Planner (PP)
Rob Graham, City Attorney (CA)
1. CALL TO ORDER AND ROLL CALL
The meeting was called to order at 6:00 p.m.
2. APPROVAL OF MINUTES
A. Approve minutes of the February 17, 2026 regular meeting of the Community
Development Board.
MOTION: To APPROVE the minutes of the February 17, 2026 Community Development
Board meeting as amended.
Motion: Jeff Haynie
Second. Ellen Golombek
Kirk Hansen
For
Gregory (Greg) Beliles
For
Ellen Golombek (Seconded By)
For
Richard Arthur
For
Jeff Haynie (Moved By)
For
Doug Moody
For
Rick Ferrin
For
Motion passed 7 to 0.
3. OLD BUSINESS
There was no old business.
Community Development Board (CDB)
March 17, 2026
4. NEW BUSINESS
A. 1067 Beach Avenue ZVAR26-0006 (Mandarin Emporium, Inc.)
Request for a variance to Section 24-108 (e) and Section 24-85(b)(1) to allow for the
expansion of a nonconforming structure and continue the expansion into the required
side yard setbacks.
Principal Planner and Environmental Coordinator Payton Jamieson presented the
variance application for 1067 Beach Avenue. She explained that this was a request for a
variance to sections 24-108(e) and 24-85(b)(1) to allow for the expansion of a
nonconforming structure and continue the expansion into the required yard setbacks.
Planner Jamieson provided detailed background information, noting that the property is
located near the corner of Eleventh Street and Beach Avenue and is zoned residential
general multifamily. The house was built in 1927, making it technically nonconforming,
and the lot is also nonconforming at 30 feet in width when the zoning district requires
40 feet. She explained that both the lot and structure are nonconforming, with the existing
structure not meeting the required side yard setback of 15 feet total, with neither side
being 5 feet or more.
She described the existing deck on the structure that was permitted in 1993 for deck
replacement, though city records indicated the original deck permit was unclear. The
specific variance request related to a side yard deck expansion into the side yard. Prior
to 1993, projections were not considered encroachments into required rear yards under
zoning code requirements, including uncovered steps, balconies, and porches.
Planner Jamieson highlighted that there is currently unpermitted work on the property
with an active code enforcement violation. The variance came to attention due to a
request for a DEP (Department of Environmental Protection) letter, as they needed a
zoning confirmation letter for their project that met zoning code requirements, which it
did not based on setbacks.
She provided a detailed overview of the current conditions, showing that the south side
violates setbacks at 2.5 feet from the property line and the north side at 5.2 feet from the
property line. The applicant's proposal involves expanding the porch further into the rear
yard and adding storage underneath the porch, changing it from an open porch to an
enclosed structure.
Planner Jamieson explained why the variance was needed, describing it as "a classic
condition of a change of not necessarily use, but of the current status of a nonconforming
structure similar to the carport one we had previously." She noted that the porch
constitutes a change from an open structure to an enclosed inhabitable structure, as
they're not necessarily enclosing the porch but enclosing what's underneath it.
She presented various plans and elevations showing the proposed expansion, explaining
that the existing porch currently violates side yard setbacks, therefore requiring a
variance, and the expansion would follow the same wall plane, still extending into the
Community Development Board (CDB)
March 17, 2026
setbacks. The plans showed dimensions changing from 12 feet by 22 feet to include a 7 -
foot extension towards the rear yard.
Planner Jamieson showed photographs of the current structure provided by the applicant,
noting the active stop work order on the property. She displayed images from various
angles showing the tight distance constraints, particularly the 2.5 -foot side setback on
the south side.
She outlined the specific variance requests from two sections of the code: Section 24-
85(b) relating to nonconforming structures, which states that no nonconforming structure
shall be expanded unless the expansion complies with applicable provisions including
building setbacks, and the specific request regarding required side setbacks of the zoning
district.
Planner Jamieson quoted directly from the zoning code regarding the intent of the
nonconforming section: "to recognize that the legal rights entitled to the property owners
of existing nonconforming uses and structures and to permit such nonconformities to
continue in accordance with such rights, but not to otherwise encourage their continued
survival."
She concluded by outlining the grounds for decision, stating that the board must find one
or more of the following conditions applicable to grant the variance: exceptional
topographical conditions, surrounding conditions impacting the property differently
from others, exceptional circumstances preventing reasonable use compared to other
properties, onerous effect of regulations enacted after platting or development, irregular
shape of the property, or substandard size of lot warranting the variance for reasonable
use.
Chair Hansen asked for questions from staff. Board member Greg Beliles inquired about
the side setbacks piece and the extension toward the ocean, asking if that would be an
issue were it not for the side setbacks. Planner Jamieson confirmed that was correct,
explaining that rear yard setbacks are quite large on oceanfront properties and they rarely
have anyone who goes into the rear yard setbacks because of oceanfront regulations.
Ellen Golombek asked several clarifying questions. She first asked about the house being
built in 1927, and Planner Jamieson confirmed that was according to the property
appraiser, though city records don't necessarily go back that far. Regarding the decking
structure, she explained they have records of an attempt to rebuild the decking in 1993,
but can't go back further, so they assume the deck was part of the house sometime before
1993.
Ellen Golombek asked if a variance was approved to fix the decking in 1993, and Planner
Jamieson clarified that no variance was needed because it was permitted. She explained
that prior to 1993, projections were not considered encroachments into required rear
yards, which included uncovered porches, and this stipulation took precedent over
existing zoning code. Ellen Golombek then understood that the current issue was
triggered because they're enclosing the underneath area, changing the existing use of the
structure from an area that's not enclosed to an enclosed area for storage use.
Community Development Board (CDB)
March 17, 2026
Chair Hansen sought clarification, asking if the structure had already been built without
a permit. Planner Jamieson explained that part of the structure had been built, though she
didn't know how far along they were in completing the whole project. She noted that
staff was notified of the project occurring prior to receiving the variance request,
conducted due diligence, and issued a stop work order because there was no active
permit.
She detailed the process for oceanfront lots, explaining that they first need building
permits from the state, but must get a zoning verification letter from the city confirming
the project fits zoning requirements, which it currently does not. The variance is needed
to address local level requirements, which would then allow for a DEP letter to go to the
state for building plan approval, after which they could return to the city for a permit.
Chair Hansen asked if all the construction that had been done was violating the side yard
setbacks, and Planner Jamieson confirmed this based on the plans submitted.
Ellen Golombek asked why they would have to come back to the city again, and Planner
Jamieson explained that the DEP letter allows them to get state sign -off that their project
meets zoning requirements, and while the state looks at oceanfront lot requirements and
may approve the project for state requirements, that doesn't issue a permit to build - they
still must return to the city for a full permit. She clarified this process is unique to
oceanfront lots in Atlantic Beach.
Chair Hansen then called for the applicant's representative, Rich Trendel with Petra
Contracting, who identified himself as representing the property owner and serving as
the contractor called when they received the stop work order. He explained that he didn't
know the whole front end of the situation, as the property owners initially thought they
were "just enclosing under this thing" and didn't realize the full permitting requirements.
Rich Trendel described how he got involved, bringing in Kevin Bartle to handle state -
level requirements and working with Planner Jamieson and Code Enforcement Officer
Jose Gonzalez on the stop work order to "bring everybody together" and "get this taken
care of correctly." He explained the project as basically trying to enclose underneath a
porch, with the depth aspect toward the backside mimicking existing stairs for aesthetic
appeal.
He provided background that the house renovation occurred in 2017-18, originally being
the Lambert house owned by David Lambert, and that the current owners are a family of
five in a four-bedroom house needing more storage room. He explained that the man
living in the house works for a church on San Pablo, runs production for off -campus
activities, and has equipment needing tempered space and security, which would be the
primary use of the enclosed space.
Chair Hansen asked for questions for the applicant, and seeing none, thanked Rich
Trendel. He then opened the floor for public comment, noting he saw two people in
attendance.
Community Development Board (CDB)
March 17, 2026
Michael Sherrod, identifying himself as a resident of Atlantic Beach, spoke in favor of
the variance. He acknowledged it was "obviously a very tough lot" with only 30 feet
width and setbacks of 2.5 feet on one side and 5 on the other. He stated that he didn't
think the proposed expansion would affect neighbors and that he would "personally like
to see a family be able to expand their storage and help their growing family." He
concluded that he thought "this is a ballpark win for them and the city."
Chair Hansen asked if anyone else wished to speak, and seeing no one, closed the public
comment period and brought the matter to the board for discussion and motion.
Rick Ferrin raised a question about the application stating the space would be used for
storage, asking if this had any zoning impact, particularly since they were installing "nice
patio doors on the oceanfront" for storage use. He wondered if the space were used for
something other than storage, whether that would matter. Planner Jamieson responded
that it would only matter for potential code enforcement issues if they stored
inappropriate items in specific areas, but she didn't see that being the case here. She
explained that code enforcement would get involved if needed, and that the enclosure
technically creates a room that can be used however the owners want.
Ellen Golombek performed calculations aloud, noting that a 30 -foot wide lot with 15 feet
required for setbacks would result in only a 15 -foot wide house, which she considered
small even by her standards. She stated that while she's typically not one to support
reducing setbacks, given that the house was built in 1927 and applauding the owners for
trying to preserve the original house rather than demolishing it, she didn't know what
else they could do. She observed that none of the existing structure was conforming and
concluded they should "just get it right as far as meeting variances and things like that
and let them move forward with what they want to do."
Chair Hansen thought the request was actually to violate the 5 -foot setback on the side
at 2.5 feet, seeking clarification. Planner Jamieson clarified that they're trying to leave
the existing porch structure as is, with the south side currently at 2.5 feet and north side
at 5.2 feet - those setbacks wouldn't change. However, the issue was changing the
existing use of the structure, requiring a variance because even if the structure
dimensions stay the same, the use isn't staying the same. She compared it to the previous
carport case where the structure wasn't changing dimensionally, but the use was
changing from open to enclosed, which does change the use of the proposed structure,
and nonconformity regulations address both uses and structures.
Chair Hansen asked if anyone else had questions or opinions. Jeff Haynie indicated he
was ready to make a motion, and Chair Hansen gave him the opportunity after asking if
others wanted to weigh in first.
MOTION: To APPROVE ZVAR26-0006 on grounds #5 "Irregular shape of the property
warranting special consideration" and #6 "Substandard size of a lot of record warranting a
variance in order to provide for the reasonable use of the property.
Motion: Jeff Haynie
Second: Ellen Golombek
Community Development Board (CDB)
March 17, 2026
Kirk Hansen
For
Gregory (Greg) Beliles
For
Ellen Golombek (Seconded By)
For
Richard Arthur
For
Jeff Haynie (Moved By)
For
Doug Moody
For
Rick Ferrin
For
Motion passed 7 to 0.
B. Section 24-89 Floodplain Storage Code Discussion
Chair Hansen introduced the discussion that the board had the previous week regarding
floodplain storage, asking Planner Jamieson to introduce the topic.
Planner Jamieson explained that staff was tasked from previous meetings regarding
variances concerning floodplain storage to develop a legislative change to the code, as it
wasn't clearly indicating specific requirements for floodplain storage and how it could
be amended, especially for areas subject to the intercoastal waterway system and the
natural floodplain existing there.
She provided detailed technical background, explaining that in riverine floodplain areas,
placement of fill below the base flood elevation level where floodwaters are expected to
reach during a 100 -year flood event reduces natural storage capacity for floodwaters.
When this storage capacity is diminished, floodwaters can be displaced, potentially
increasing flood elevations and exacerbating flooding in surrounding areas, which is why
compensatory flood storage is typically required when fill is placed within riverine
floodplains.
In contrast, she explained that properties adjacent to the intercoastal waterways are not
subject to flooding caused by upstream riverine flow. Instead, flooding in these areas
typically occurs through inundation as water levels in the intercoastal waterway change
and expand outward due to tidal influence. Because the intercoastal represents a very
large body of water with substantial storage capacity, the addition of relatively small
amounts of fill associated with residential development along the shoreline does not
measurably affect the elevation of the 100 -year flood elevation.
Planner Jamieson summarized that compensatory storage is critical to riverine systems
where fill placement can increase flood elevations by displacing floodwaters, but this is
not directly associated with large bodies of water such as the intercoastal waterway
system or properties directly adjacent to the waterway system, because small-scale fill
associated with single residential structures will not significantly or meaningfully affect
those waterways.
Community Development Board (CDB)
March 17, 2026
She presented the proposed adjusted language for floodplain storage in the zoning code:
"For areas located within the special flood hazard area by the hundred year flood plain,
where a base flood elevation has been defined by the Federal Emergency Management
Agency, FEMA, on flood insurance rate maps (FIRMS), there shall be no net loss of
floodplain storage for development occurring adjacent to waterways other than the
intercoastal waterway system and for drainage ditches or canals that do not discharge
into the intercoastal waterway. Site grading shall provide compensatory storage on-site
to offset any loss of storage or any loss of flood storage volume resulting from the fill
placed on-site."
She continued reading the proposed language: "This storage is in addition to the storage
required for an increase in the impervious surface area. The applicant shall provide
signed sealed engineering plans and calculations documenting that there's no net loss
requirement is met."
Planner Jamieson explained that this language was specific to lot location, and from both
zoning and public works perspectives, drainage matters because grading can change
where waterways go. When adjacent to an intercoastal waterway system, no matter what
is done to lot grading, it won't affect where water naturally goes, but everywhere else in
Atlantic Beach, that can occur. She noted that ecologically and logically, it doesn't work
that way because of tidal influence, especially from the St. Johns River, so it's not
significant to hold applicants accountable for floodplain storage in these areas, though
they still have both floodplain storage and stormwater storage requirements based on
impervious ratios.
Chair Hansen asked for questions regarding the proposal. Jeff Haynie raised concerns
about the language in the first paragraph, specifically the last clause "and for drainage
ditches or canals that do not discharge to the intracoastal waterway." He sought
clarification whether the intent was for those ditches and canals to be excluded from the
no net loss requirement along with properties adjacent to the ICW.
Planner Jamieson read through the language again, confirming that there shall be no net
loss of floodplain storage for development occurring adjacent to waterways other than
the intercoastal waterway and for drainage ditches or canals that do not discharge into
the intercoastal waterway.
Greg Beliles suggested that what the city was attempting to accomplish was ensuring
that even if there was no net loss, water could still spill onto neighboring properties, and
they were trying to preclude that from happening with this language, asking if this was
based on property location. Planner Jamieson confirmed this was correct.
Jeff Haynie expressed concern that there were two things the language was trying to
exclude from the no net loss requirement: properties adjacent to the ICW and those
adjacent to drainage ditches or canals that don't discharge into the ICW. He found this
potentially confusing.
Chair Hansen offered his interpretation that for drainage ditches and canals that do not
discharge into the intercoastal waterway, the requirement applies to them if they do not
Community Development Board (CDB)
March 17, 2026
discharge into the intercoastal waterway. Jeff Haynie acknowledged this reading but
worried about the stacking of negatives making it unnecessarily confusing.
Jeff Haynie suggested separating this into two clear distinct sentences and restructuring
so all requirements are together, then having exceptions listed separately, rather than
having "requirement, exception, requirement" structure.
Planner Jamieson acknowledged they could clean up the language and highlighted that
site grading requirements were directly related to storage requirements, noting they have
both storage requirements and site grading for on-site stormwater, which is different
from floodplain requirements. She suggested this was trying to highlight that there are
additional storage considerations for waterway storage, whether stormwater or
floodplain.
Chair Hansen stated that he had reviewed this with Amanda the previous week and told
her he liked the simplicity of it, finding it very clear. He acknowledged Jeff Haynie's
point about stacking negatives creating potential confusion but wouldn't want to change
it significantly, though he understood it would need to be put in proper ordinance format
with "wherefores and whereas." He maintained that in his "simple mind, it's not
confusing."
Ellen Golombek agreed somewhat with Jeff Haynie, stating that while it was easier for
committee members to understand after explanation and working on it the previous
week, she found the last sentence in red in the first paragraph "just a tad confusing." She
supported dividing that into two different sentences to make it easier to understand and
read, though she wasn't sure about putting all requirements in one place and exceptions
in another.
Rick Ferrin commented that he had to read it several times before understanding it, but
did eventually understand what it was trying to say. He agreed that if they could clarify
it so "you only have to read it once, that's maybe good."
Rick Ferrin noted that the first page explained riverine floodplain areas quite well, then
contrasted properties adjacent to intercoastal waterways not being subject to flooding
from upstream riverine flow. He agreed the explanation was clear but found the second
page's first paragraph about floodplain storage requiring multiple readings, particularly
the sentence starting with "there shall be no net loss of floodplain storage."
Chair Hansen concluded that there was consensus they were on the right track but needed
to make changes so it would be understandable on first reading rather than requiring
multiple readings to understand the negatives and double negatives.
Jeff Haynie raised another issue about the need for variance requests, referencing
confusion from a particular case where an applicant submitted signed and sealed
engineering plans showing no net loss, but the city still required a variance. He wondered
if language was needed about city review and approval processes to avoid future
confusion where applicants claim they submitted required documentation, but the city
questions it.
Community Development Board (CDB)
March 17, 2026
4
6.
7.
Attest:
Planner Jamieson explained that floodplain storage and no net loss are both required,
going hand in hand. Even if plans are submitted, if they don't show no net loss, the city
would still require floodplain storage because the plans aren't demonstrating no net loss.
She clarified that no net loss is a requirement regardless, but applicants still must provide
floodplain storage, and the goal of floodplain storage is no net loss, though this can be
achieved in different ways.
Jeff Haynie suggested it might be helpful to clarify the engineering plan requirements
and what happens if the city questions the calculations, referencing the previous case
where the city appeared to not accept the submitted plans.
Rick Ferrin recalled that they were questioning the calculations regarding whether there
was actually no net loss of storage capacity, and they wanted the city engineer to verify
or validate the calculations made by the applicant's engineer.
Chair Hansen acknowledged they clearly understood what the board was trying to
achieve and thanked staff for their work and quick action after the previous month's
meeting. He noted they had received several similar cases and wanted to avoid confusion
by clarifying the requirements.
REPORTS
There were no reports.
PUBLIC COMMENT
There were no public comments.
ADJOURNMENT
There being no further discussion, Chair Hansen declared the meeting adjourned at 6:40 p.m.
"�ndz
Amanda Askew
Kirk Hansen, Chair
Community Development Board (CDB)
March 17, 2026