Permits Folder 363 Ahern Street1 • PER1VIlT 1N~RKSHEET Job Address: Property Owner: Contractor: Permit #: Building Inspections: Tree Permit # Electrical Permit # Certificate of Occupancy ~ ~~ ~ i Footing Slab. Tie Beam Lintel Nailing /Sheathing Framing /Cover Up Insulation Final Building Type Work: Phone # Phone # Date Issued: YES ~b-333z~ Temp, Pole Permit # . NO Temp. Power Letter Received: YES NO Date /Copy to JEA Inspections: Rough Electric . Released to JEA ' Temp. Power Released to JEA Temp. Pole Released to JEA Final Released to JEA Mechanical Permit # • -Inspections: Rough Final Plumbing Permit # . Inspections: Rough / Underslab . 0 Water f Sewer Drainage Inspection: Pool Permit # Inspections: Steel Grounding Roofing Permit # . Inspections: Nailing. /Sheathing Fire Inspection: Failed Inspections: Date /Copy to JEA j;ol~h ~~~ ~.~t, o b Topout Final ~. Z94 ~.5 Final Final Final Date Paid: n~+o p~~.~• ~ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH FL 32233 C E R T I F I CAT E O F O C C U PAN C Y P E R M A N E N T Issue Date 4/10/07 Parcel Number Property Address 363 AHERN ST ATLANTIC BEACH FL 32233 Subdivision Name Legal Description . Property Zoning TO BE UPDATED Owner NELSON Contractor DAVIE, JOHN E. 904 249-3418 Application number 06-00032183 000 000 Description of Work RESIDENTIAL ADD/RENOVATE/ALTER Construction type . Occupancy type Flood Zone Approved VOID UNLESS SIGNED BY BUILDING OFFICIAL Building, Planning & Zoning Inspection Deparhnent Date Requested: Contractor Name: Permit #: Property Address: Legal Description: Improvements to accordance with occupancy as: CITY OF ATLANTIC BEACH CERTIFICATE OF OCCUPANCY WORKSHEET ~9, o? .~~ ~~ ~ ~(o3 ~y~r~ ~~ the above-described property have been completed in the terms of the permit and are certified to be ready for ^ Single-Family Residence ^ Commercial Other: ~n ~7~D1.~-~ f Lowest Floor Elevation: Required As Built The following must be completed before issuing Certificate of Occupancy: Department Date Notified Date Approved Approved By Fire Dept. Public Works Q~ - ~ ~ Planning Dept. Building Dept. Final Survey with FFE All Re-Inspect Fees Paid ^ Yes [~1 No ^ Yes L~-P~"o /r/1~// `L CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Application Number 07-00000130 Date 2/13/07 Property Address 363 AHERN ST Application type description PLUMBING ONLY Property Zoning TO BE UPDATED Application valuation 0 ---------------------------------------------------------------------------- Application desc relocate and increase meter size ---------------------------------------------------------------------------- Owner ------------------------ MAFREDAS C/O 8/9/93 363 AHERN STREET ATLANTIC BEACH FL 32233 Contractor ------------------------ CITY OF ATLANTIC BEACH ATLANTIC BEACH FL 32233 ----------------------- Permit -------------------------------- PLUMBING PERMIT ------- -------------- Additional desc . Permit Fee .00 Plan Check Fee .00 Issue Date 2/13/07 Valuation 0 Expiration Date 8/12/07 ----------------------- Special Notes and ------------- Comments ------------------- ------- -------------- relocate and increase from 3/4 in to 1 in ----------------------- Other Fees ------------- ------------------- WATER CONNECT/METER ------- ONLY =------------- 560.00 --------------------- WATER CROSS CONNECT ION 35.00 -- Fee summary ---- ------------- Charged ------------------- Paid Credit ------- ed -------------- Due ------------- Permit Fee Total ---------- .00 ---------- ------- .00 --- -- .00 -------- .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 595.00 595.00 .00 .00 Grand Total 595.00 595.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUII,DING CODES. Graham Shirle From: Kaluzniak, Donna Sent: Tuesday, February 13, 2007 9:44 AM To: Graham Shirley Cc: Walker, Chris Subject: RE: Increase and move meter Shirley, the cost will be $560 + $35 cross conn = $595. -Donna From: Graham Shirley Sent: Tuesday, February 13, 2007 9:38 AM To: Kaluzniak, Donna Subject: Increase and move meter Chris w/ Via Mare' has a 3/4 in irrg meter between the addresses of 357 and 363 he needs to have that increased To 1 in and needs to have it relocated, will you send me a price. Shirley 1 ~~ iS~a ~.~ c, J ~i ~R. 1/~ ~ y~ L I N5~ f~~ h~ ~ ~ fi .~~, r, .I ~ ~ a~ i;~ ~)~I ' n~aT~ g ~~~ g~~ g3~ ~~ ~ (~ 3 ~, s 1 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Application Number 06-00032183 Date 3/08/06 Property Address 363 AHERN ST Tenant nbr, name APTS TO CONDOS Application description RESIDENTIAL ADD/RENOVATE/ALTER Property Zoning TO BE UPDATED Application valuation 180000 Owner Contractor ------------------- ----- ------------------ NELSON ------ DAVIE, JOHN E. 2404 HUBBARD ST. ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32206 (904) 249-3418 ------------ --------------- ----------------------- Permit -------------------------- BUILDING PERMIT Additional desc . Permit Fee 700.00 Plan Check Fee 350.00 Issue Date Valuation ------------ 0 --------------- ----------------------- Other Fees -------------------------- WATER IMPACT FEE 320.00 WATER CROSS CONNECTION 35.00 Fee summary Charged Permit Fee Total 700.00 Plan Check Total 350.00 Other Fee Total 355.00 Grand Total 1405.00 Paid Credited Due ---------- ---------- ---------- 700.00 .00 .00 350.00 .00 .00 355.00 .00 .00 1405.00 .00 .00 r MAR 0 ~ 2006 (;k#~ PERNIIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. -: ~.~. ~. ~* ~:~; ~ ~. +~ - ~~ BUII,DING OFFICIAL _I~~ l~r. 0 'r \: "~ ' t" CITY OF ATLANTIC BEACH L °J ~~._~~- ~~ ~ `~ ~~ PERMIT CALCULATION SHEET ., . ~~ JiiJ~r Date ~ ~ ~ ~ ~~ Permit Number ~.~- Address ~ ~D ~ ~~ Ifi/_ ~ ~ ~ ,% " , rL ~ y ^-' / ~ Contact Name ~u ~+,..~ '~ ,~ ~ r Phone Heated Square Footage @ $ per sq ft = $ Garage /Shed @ $ per sq ft = $ i LJ h Carport /Porch ~ ~ ~ per sq ft = $ c/' S h~ ~' Deck @ $ ~_ per sq ft = $ ~ ~r- Patio @ $ per sq ft = $ TOTAL VALUATION: $ /;~C Total Valuation I S` $ Remaining Value $ per thousand or~ portion thereof CONSTRUCTION TYPE:_~~ TOTAL BUILDING FEE $ ZONING: ~, ~ Z + %2 Filing Fee $ FLOOD ZONE: ~. OFireplaces @ $35.00 $ t i 11VIPERVIOUS SURFACE: 7 S U ~~ AB CONSTRUCTION SURCHARGE $ CAPITAL IMPROVEMENT $ CITY RADON SURCHARGE $ ~ SECTION H Il1~'ACT FEE $ I SEWER IlVIPACT FEES $ SEWER TAP FEES $ '~, ST CONSTRUCTION SURCHARGE $ STATE RADON SURCHARGE $ WATER CONNECT/METER ONLY $ WATER CONNECT/TAP & METER $ WATER CROSS CONNECTION $ 3 ~' WATER IMPACT FEE $ 3 z v OTHER $ GRAND TOTAL DUE: $ 1/13/03 . ~~ `~'~~~'' ~ CITY OF ATLANTIC BEACH c.~~~--~ ~~ ~. ~ BUILDING /ZONING DEPARTMENT L. iii ins ~ r 800 Seminole Road OeR Atlantic Beach, Florida 32233 ri 13t ~. (904) 247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # ~ ~ - .~ Z / ~ .3 Property Address: ~ (0 ~ ~/ 1 ~ /" ~-/ d'T Applicant: ~.l J ~ V / Project: ~~//~4 .S This permit application has been: Approved ~. ~ Reviewed and the following items need attention: Please re-submit your r1application when these items have been completed. Reviewed By: ,,~~= ~r' ~" _ Date: ~ `~ ~ ~ ~'' ~~ Date Contractor Notified: ,4 r' '"Sv~''~',' CITY OF ATLANTIC BEACH ,~~ ~'~~ BUILDING PERMIT APPLICATION x~.a ='' (Alterations & Additions) ~ a~.- . Date: x Job Address: ~ ~ 3 ~~~' ~ 57' ~~. __~~.~N7~~ ~'~(~ ~ ~ ~3.•1~1. Owner of Property: ,~„ ~ ~ ,1~ ~ ~ ~., 'S© ~ Address: ~ ~ ~ - ~~ S~~~Y 1~'~'t,~N`t1G ~t~lG'~ ~~elephone: ~ ~ ~ • ~y 07 . ~ 79t~.. Legal Description: Block Number: ~ Lot Number: ~ ~ Zoning District: ~~'~ Contractor: 1~~~ ~. bAvts~ ~~~~, C,prt~}Z,r~,State License Number: ~~ ''~?(~'~? ~g92.. ContractorAddQress: ~$~•- td~'t ~`~~,~~F ~TI.Qn~'iG ~eQG~t. ~~, ~'~3'3 Telephone: 1 e'~' ~ .~~~{-«fi,J~~~ Fax: ~O~•'~~.p]~ ~1~~~ Describe proposed use and work to be done: tc~e;~tden~idL ~lY7C~t'~f'Vit.;'2t4tiYf~a Present use of land or building(s): Valuation of proposed construction: ~ g 7t8 oot~ What are the dimensions of the added space: ~7 feet x ~(' feet ,~ Will the added area be heated and cooled? ~,~ New electrical or increase in service? __~ --L "? Add plumbing fixtures? ~_ Add fireplace? ~. Add heating/air conditioning? ~~-,,~ Is approval of Homeowner's Association or other, private entity required? ~('~ If yes, please submit with this application. Will this project involve changes in elevation, site grade or any use of fill material, or the addition of 5% or more to the original impervious area or the removal of any trees? ^ NO. Applicant certifies that no change in site grade, impervious area or fill material will be used on this project. [YES. See Step 2 below. Approval of the Public Works Department is required prior to issuance of a Building Permit. ^ O. Applicant certifies that no trees will be removed for this project. [YES. Removal of Trees will be required for this project. TREE REMOVAL PERMIT IS REQUIRED. Tree Removal Permits to be reviewed by the Tree Conservation Board, which meets two times each month. Procedure: In order to expedite issuance of permits, please follow all steps and provide all information as appropriate. Incomplete applications may result in delay in issuance of permit. STEP 1. Verify zoning designation and proper setbacks for the proposed construction. If you are unsure of this information, please contact the Planning and Zoning Department at 904-247-5826. In order to correctly verify zoning designation, please have Property Appraiser's Real Estate Number available. STEP 2. Contact the City of Atlantic Beach Department of Public Works to determine if apre-construction or post-construction topographical survey or grading plan is required. (If not required, written verification must be provided with this application.) The Department of Public Works is located at: 1200 Sandpiper Lane, Atlantic Beach, FL 32233 Telephone: (904) 247-5834 STEP 3. Submit Tree Removal Application if trees are to be removed or relocated. STEP 4. Please submit Building Permit Application, Energy Code Forms, Notice of Commencement, Owner/Contractor A1Edavit if owner is contractor, and four (4) complete sets of construction plans to the Building Department, which is located at the Atlantic Beach City Hall, 800 Seminole Road, Atlantic Beach, FL 32233 Telephone: (904) 247-5826 800 Seminole Road • Atlantic Beach, Florida 32233-5445 Telephone: (904) 247-5800 • Fax: (904) 247-5845 • http://www.ci.atlantic-beach.fl.us Page 2 Revised 8/04 In addition to construction and engineering detail, plans must contain the following information as appropriate for the type of work being performed. Scale of drawings should be sufficient to depict all required information in a clear and legible manner. I. Current survey showing the property boundary with bearings and distances and the legal description. 2. Location of all structures, temporary and permanent, including setbacks, building height, number of stories and square footage. Identify any existing structures and uses. 3. If requued by the Department of Public Works, apre-construction topographical survey. 4. Any significant environmental features, including any jurisdictional wetlands, CCCL, natural water bodies. 5. Impervious Surface area calculations: include driveways, sidewalks, patios and other Impervious Surfaces. Swimming pools may be excluded from total Impervious Surface. 6. Other information as may be appropriate for individual applications. I hereby certify that al ormation provided with this plication is correct. Signature of owner: Date: ~' L7* ~ ~v I hereby certify that I have read and e~ce(mined this application and know the same to be true and correct. All provisions of the laws and ordinances governing this type of work will be complied with, whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any federal, state or local rules, regulations, ordinances, or laws in any manner, including the governing of construction or the performance of construction of the property. I understand that the issuance of this permit is contingent upon the above information being true and Signature of Contractor: ~• Q~ Address and contact information of person to receive all correspondence regarding this application (please print). Name: 1/1! N G t,~,~Y~~ •~ t~1~~~.b~.l. ~~~Ul~. . Mailing Address: ~~~ a ~ ~'7> ~J~ '~~~• ~~.tr~ iJi'lt_, !3"~~~Gf~l • ~L • ;`~'2'~3'~ Telephone: ~~~~ ~J2 ~ (~ Fax: ~j~T 7 ~ ~Q ~ j E-Mail: C~Q,V tQ„I~YT$ !,}~' Q; ~. ~., . AS TO OWNER: Sworn to and subscribed before me this ~~_ day of v , 20~. State o of val •~~:Y's% LA RON JONES *~ ~:= MY COMMISSION # DD 374556 EXPIRES: June 25, 2006 %¢; cd'rv,, Bonded Thru Notary Public Underwriters •' AS TO CONTRACTOR: and that the plans and supporting data have been or shall be provided as required. Notary's Signature: Personally known ^ Produced identification Type of identification produced Sworn to and subscribed before me this ~~ day of tr-~i , 20~. State of Florida, County of Duval ~~ ~:;~+Y "i;~;.% LA RON JONES .: MY COMMISSION # DD 374556 _;~ Qa EXPIRES: June 25 2006 •.. %F q ~ n°.•'~~ Bonded Thru Notary Public Undenvdters y Notary's Signature: ` ^ Personally known [j~-'Produced identification Type of identification produced ~~/,{-~Q 800 Seminole Road • Atlantic Beach, Florida 32233-5445 Telephone: (904) 247-5800 • Fax: (904) 247-5845 • http://www.ci.atlantic-beach.fl.us Page 3 Revised 8/04 . ~ 4Y n z ''~ FORM 600A-2004 Energyr;a g ®A4.0 1~ FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residenfiial Whole Building Performance Method A Project Name: Via Mare Unit Four Address: Ahern St ,, ~' City, State: Atlantic Beach, FI Owner: Climate Zone: North Builder: Permitting Office: Permit Number: Jurisdiction Number: ~I Atlantic Beach 261100 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap: 42.0 kBtu/hr _ 3. Number of units, ifmulti-family 1 _ SEER: 12.00 _ 4. Number of Bedrooms 2 _ b. N/A 5. Is this a worst case? No _ _ 6. Conditioned floor area (ftx) 1736 ftx _ c. N/A _ 7. Glass typel and area: (Label regd. by ] 3-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems _ (or Single or Double DEFAULT) 7a. (Dble Default) 282.0 ft= _ a. Electric Heat Pump Cap: 42.0 kBtu/hr _ b. SHGC: HSPF: 7.10 _ ' (or Clear or Tint DEFAULT) 7b. (Clear) 282.0 ftx _ b. N/A 8. Floor types ~ a. Raised Wood, Stem Wall R=19.0, 36.Oftx _ c. N/A _ _ ~ b. N/A _ _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 50.0 gallons _ a. Frame, Wood, Exterior R=19.0, 1529.0 ft' _ EF: 0.91 _ b. Frame, Wood, Adjacent R=l 1.0, 378.0 ftx _ b. N/A _ c. N/A _ ' d. N/A _ c. Conservation credits _ _ e. N/A _ (HR-Heat recovery, Solar 10. Ceiling types _ DH.P-Dedicated heat pump) a. Under Attic R=30.0, 872.0 fox 15. HVAC credits _ b. N/A - (CF-Ceiling fan, CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts _ PT-Programmable "Thermostat, a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft MZ-C-Mul6zone cooling, ' b. N/A MZ-H-Multizone heating) Glass/Floor Area: 0.16 Tota! as-built points: 19764 pgSS Total base points: 25245 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. .-~ PREPARED BY: ~'~ ~ ~ _ DATE: 0 1 I hereby certify that this buildin , a designed, is in compliance with the Florida Energy de. OWNER/AGENT: /~ DATE: j • • d ~ Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building wil- be inspected for compliance with Section 553.948 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnerovGauoe® (Version: FL RCSR v4 nl FORM 600A-2004 EnergyGauge® 4.0 SUIr1111AER CALCULATIONS Residential Whole Building Performance Method A -Details ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: BASE AS-BUILT GLASS TYPES .18 X Condition ed X BSPM =Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF =Points .18 1736.0 20.04 8282.1 Double, Clear E 1.3 18.0 16.0 42.06 1.00 670.4 Double, Clear E 1.3 18.0 15.0 42.06 1.00 628.5 Double, Clear E 1.3 18.0 6.0 42.06 1.00 251.4 Double, Clear N 1.3 0.0 20.0 19.20 1.00 382.5 Double, Clear W 9.0 8.0 8.0 38.52 0.50 154.2 Double, Clear N 10.0 8.0 10.0 19.20 0.68 129.8 Double, Clear W 1.3 0.0 50.0 38.52 1.00 1919.7 Double, Clear S 1.3 8.0 13.0 35.87 0.95 442.1 Double, Clear W 1.3 8.0 4.0 38.52 0.97 149.9 Double, Clear E 1.3 8.0 16.0 42.06 0.97 654.1 Double, Clear N 10.0 8.0 24.0 19.20 0.68 311.4 Double, Clear N 10.0 8.0 10.0 19.20 0.68 129.8 Double, Clear E 10.0 8.0 24.0 42.06 0.46 467.5 Double, Clear N 1.3 8.0 7.0 19.20 0.98 131.3 Double, Clear W 1.3 8.0 50.0 38.52 0.97 1873.2 Double, Clear S 1.3 8.0 9.0 35.87 0.95 306.1 As-Built Total: 282.0 8802.0 WALL TYPES Area X BSPM =Points Type R-Value Area X SPM = Points Adjacent 378.0 0.70 264.6 Frame, Wood, Exterior 19.0 1529.0 0.90 1376.1 Exterior 1529.0 1.70 2599.3 Frame, Wood, Adjacent 11.0 378.0 0.70 264.6 Base Total: 1907.0 2863.9 As-Built Total: 1907.0 1640.7 DOOR TYPES Area X BSPM =Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 52.0 6.10 317.2 Exterior 52.0 6.10 317.2 Base Total: 52.0 317.2 As-Built Total: 52.0 317.2 CEILING TYPES Area X BSPM =Points Type R-Value Area X SPM X SCM = Points Under Attic 872.0 1.73 1508.6 Under Attic 30.0 872.0 1.73 X 1.00 1508.6 Base Total: 872.0 1508.6 As-Built Total: 872.0 1508.6 FLOOR TYPES Area X BSPM =Points Type R-Value Area X SPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 19.0 36.0 -1.50 -54.0 Raised 36.0 -3.99 -143.6 Base Total: -143.6 As-Built Total: 36.0 -54.0 FORM 600A-2004 EnergyGauge~ 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A -Details ~ ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: ~ BASE AS-BUILT INFILTRATION Area X 13SPM =Points Area X SPM = Points 1736.0 10.21 17724.6 1736.0 10.21 17724.6 Summer Base Points; 28532.7 Summer As-Built Points: 29739.0 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System -Points) (DM x DSM x AHU) {sys 1: Central Unit 42000 btuh ,SEER/EFF(12.0) Ducts:Con(S),Con(R),Int{AH),R6.0(INS) 29739 1.00 (1.00 x 1.147 x 0.86) 0.284 1.000 8387.1 28532.7 0.4266 12172,0 29739.0 1.00 0.992 0.284 1.000 8387.1 FORM 600A-2004 EnergyGauge® 4.0 VVII~ITER CALCULAT101~S Residential Whole Building Performance Method A -Details ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area XWPM X WOF =Point .18 1736.0 12.74 3981.0 Double, Clear E 1.3 18.0 16.0 18.79 1.00 302.0 Double, Clear E 1.3 18.0 15.0 18.79 1.00 283.2 Double, Clear E 1.3 18.0 6.0 18.79 1.00 113.3 Double, Clear N 1.3 0.0 20.0 24.58 1.00 491.5 Double, Clear W 9.0 8.0 8.0 20.73 1.18 195.7 Double, Clear N 10.0 8.0 10.0 24.58 1.02 250.9 Double, Clear W 1.3 0.0 50.0 20.73 1.00 1037.5 Double, Clear S 1.3 8.0 13.0 13.30 1.02 176.4 Double, Clear W 1.3 8.0 4.0 20.73 1.01 83.5 Double, Clear E 1.3 8.0 16.0 18.79 1.01 305.2 Double, Clear N 10.0 8.0 24.0 24.58 1.02 602.3 Double, Clear N 10.0 8.0 10.0 24.58 1.02 250.9 Double, Clear E 10.0 8.0 24.0 18.79 1.35 607.9 Double, Clear N 1.3 8.0 7.0 24.58 1.00 172.1 Double, Clear W 1.3 8.0 50.0 20.73 1.01 1044.0 Double, Clear S 1.3 8.0 9.0 13.30 1.02 122.1 As-Built Total: 282.0 6038.7 WALL TYPES Area X BWPM =Points Type R-Value Area X WPM = Points Adjacent 378.0 3.60 1360.8 Frame, Wood, Exterior 19.0 1529.0 2.20 3363.8 Exterior 1529.0 3.70 5657.3 Frame, Wood, Adjacent 11.0 378.0 3.60 1360.8 Base Total: 1907.0 7018.1 As-Built Total: 1907.0 4724.8 DOOR TYPES Area X BWPM =Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 52.0 12.30 639.6 Exterior 52.0 12.30 639.6 Base Total: 52.0 639.8 As-Built Total: 52.0 639.6 CEILING TYPES Area X BWPM =Points Type R-Value Area XWPM X WCM = Points Under Attic 872.0 2.05 1787.6 Under Attic 30.0 872.0 2.05 X 1.00 1787.6 Base Total: 872.0 1787.6 As-Built Total: 872.0 1787.6 FLOOR TYPES Area X BWPM =Points Type R-Value Area X WPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem Wall 19.0 36.0 0.80 28.8 Raised 36.0 0.96 34.6 Base Total: 34.6 As-Built Total: 36.0 2g,g Gne~n.,!_oi~nn~il nr•n Cn..., aANA ~fnn~ r~.._-_..n...-_.a. n-,_n.-n........ - ... FORM 600A-2004 EnergyGauge(9 4.0 1IV1~fTER CALCULATIONS Residential Whole Building Performance Method A -Details ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: BASE AS-BU[LT INFILTRATfON Area X BWPM =Points Area X WPM = Points 1736.0 -0.59 -1024.2 1736.0 -0.59 -1024.2 Winter Base Points: 12436.6 Winter As-Built Points: 12195.0 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System -Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 42000 btuh ,EEF(7.1) Ducts:Con (S),Con(R),Int(AH),R6.0 12195.0 1.000 (1.000 x 1.169 x 0.88) 0.480 1.000 6049.2 12436.6 0.6274 7802.7 12195.0 1.00 1.033 0.480 1.000 6049.2 FORM 600A-2004 EnergyGauge~ 4.0 UVATEFi HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A -Details 1 ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: 1 BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit =Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2635.00 5270.0 50.0 0.91 2 1.00 2663.96 1.00 5327.9 As-Built Total: 5327.9 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Points Paints Hot Water Points = Total Points Cooling Points + Heating + Hot Water - Total Points Points Points 12172 7803 5270 25245 8387 6049 5328 19764 PASS EneravGauaeTM' ^ca Fnrm Fnnaannd FnomuRannelalfCle[~FC'9(1M Ct Dl+CO ..w n FORM 600A-2004 EnergyGauge~ 4.0 Code Compliance Checklist Residential Whole Building Performance Method A -Details ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: , 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENT5 SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfmisq.ft. window area; .5 cfm/sq.ft. door area. "~ Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors i3< frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss orjoint members. '~ EXCEPTION; Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606,1.ABC.1,2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, ' soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IG rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a ~ sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. 1 Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, ~ have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by aH residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir '1 breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas 8~ heated pools must have covers (except solar heated), Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. ~ Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSTG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Duets in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. ~ Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. ~'` Common ceiling & floors R-11. EneravGauaeTM' DCA Form 600A-200a FnPrnv(;a~inp(Rl/FhRFR'9Md FI R!`CR „~ n ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 8b.4 The higher the score, the more efficient the home. Ahern St, Atlantic Beach, FI, 1. New construction or existing New 2. Single family or multi-family Single family _ 3. Number of units, ifmulti-family 1 4. Number of Bedrooms 2 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ftz) 1736 ftz 7. Glass typel and area: (Label regd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a. (Dble Default) 282.0 ft' ._.. b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 282.0 ft~ 8. Floor types a. Raised Wood, Stem Wall R=l9.Q 36.Oft= _ b. N/A c. N/A - 9. Wall types a. Frame, Wood, Exterior R=19.Q 1529.0 ft' _ b. Frame, Wood, Adjacent R=11.0, 378.0 ft' c. N!A - d. N/A _-- e. N/A .~ l0. Ceiling types a. Under Attic R=30.0, 872.0 ft' b. NIA c. N/A it. Ducts a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft _ b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A e. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT-Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify. that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: Cap: 42.0 kBtu/hr _ SEER: 12.00 Cap: 42.0 kBtu/hr HSPF: 7.10 Cap: 50.0 gallons EF: 0.91 ~'~~ Zlig STq`~o~ Fi lrrrr 'na x ,'' ` °`, ~~ a ~~o~ ~~~~ *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. I, f your score is 80 or greater (or 86, for a US EPAIDOE EnergyStar'~''designation), your home may qual~,for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321 /638-1492 or see the Energy Gauge web site at www., fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass out ut on ages 2&4. 1;nergyGauge® (Version: F~,RCSPB v4.0) RIGHT-J BUILDING AMALYSIS REPORT Entire House Energy Design Systems Job: 10/12/05 1085 Oek Vale Rd, Jacksonville, FI 32259 Phone: 904287-5339 Fax: 904-287-1258 Email: energydesignsystems®gmall.com •` ~ ~, ~ For: Unit Four Via Mare Ahern St, Atlantic Beach, FI Htg Clg Infiltration Outside db ((°F) 39 92 Method Simplified Inside db (°F') 72 72 Construction quality Average Design TD {°F) 33 20 Fireplaces 0 Daily range - ~ Inside humidity (%) - 50 Moisture difference (gr/Ib) - 65 it Component Btuh/ftz Btuh % of load Walls 2.0 3402 12.8 Windows 23.9 6747 25.4 Doors 15.2 789 3.0 Ceilings 1.1 1059 4.0 Floors 23.2 6123 23.0 Infiltration 22.7 7577 28.5 Ducts 878 3.3 Total 26575 100.0 V1flf1[lOW9._ oo~ ~C~4~INi~ Component Btuh/ftz Btuh % of load Walls 1.7 2845 10.0 Windows 56.0 15801 55.5 Doors 12.7 660 2.3 Ceilings 1.6 1540 5.4 Floors 0.0 0 0.0 Infiltration 6.9 2296 8.1 Ducts 1732 6.1 Internal gains 3600 12.6 Total 28474 100.0 Cooling at 84 % SHR = 2.8 ton Cooling air flow = 494 cfm/ton Cooling at 70 % SHR = 3.3 ton Cooling at 400 cfm/ton = 3.4 ton Overall U-Value = 0.167 Btuhlftz-°F Data entries checked. ,~, wr~glHtsoft Right-Suite RestdentialTM 5.0.66 RSR29784 2005-Oct-13 10:12:14 A(`,CA C:10ocuments and Settings\customer\My Doc°mams~Wrightsoft\Via Mare Unit FOUR Ahem St Atl Bch.rsr Page 1 RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House Energy Design Systems Job: 10/12105 1065 Oak Vale Rd, Jacksonville, FI 32259 Phone; 904287-5339 Fax: 904287-1258 Email: ener9Ydesig~systems(6lgmail.com w ~ • ~ For: Unit Four Via Mare Ahern St, Atlantic Beach, FI Notes: '_~. Design Infarrrnatic~n Weather: Jacksonville, Mayport Naval, FL , US Winter Design Conditions Summer Design Conditions Outside db 39 °F Inside db 72 °F Design TD 33 °F Heating Summary Building heat loss 26575 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 26575 B#uh Infiltration Outside db 92 °F Inside db 72 °F Design TD 20 °F Daily range L Relative humidity 50 Moisture difference 65 gr/Ib Sensible Cooling Equipment Load Sizing Structure 28474 Btuh Ventilation 0 Btuh Design temperature swing 3.0 °F Use mfg. data n Rate/swing multiplier 0.97 Total sens. equip. load 27619 Btuh Method Simplified Construction quality Average Fireplaces 0 He Co Area (ft) 1736 1736 Volume (fta) 15624 15624 Air changes/hour 0.80 0.40 Equiv. AVF (cfm) 209 104 Heating Equi pment Summary Make Trade Latent Cooling Equipment Load Sizing Internal gains 920 Btuh Ventilation 0 Btuh Infiltration 4579 Btuh Total latent equip. load 5499 Btuh Total equipment load 33119 Btuh Cooling Equipment Summary Make Trade Efficiency 0.0 HSPF Efficiency 0.0 EER Heating input Heating output 0 Btuh @ 47°F Sensible cooling Latent cooling 0 0 Btuh Btuh Heating temp rise 0 °F Total cooling 0 Btuh Actual hea#ing fan Heating air flow factor 1362 0.051 cfm cfm/Btuh Actual cooling fan Cooling air flow factor 1362 0.048 cfm cfm/Btuh Space thermostat Load sensible heat ratio 84 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. Wf'IgI"Tt50'FC Rfght-Butte ResldentlalTM 5.D.66 RSR29784 2005-Oct-13 10:12:14 ~~ C:\Documents and Settingslcustomer\My Documents\Wrightsoft\Via Mare Unit FOUR Ahem St Atl Bch.rsr Page 1 +~i CITY OF ATLANTIC BEACH PUBLIC UTILITT~S DEPARTMENT 1200 Sandpiper Lane Atlantic Beach, Florida 32233 (904) 247-5834 (904) 247-5843 Fax www.coab.us PLAN REVIEV~ COMMENTS Permit Application # ~ 6 - ~ Z / ~ 3 Property Address: ~ l0 3 ~J7 ,~,~ // c~ Applicant: ~19 l~ / Project: ~ ~ Your application is approved as noted by the Public Utilities Department. Final application approval must come from the Building Department. o Your permit application has been reviewed by the Public Utilities Department and the following items need attention: Please submit these requirements to the Public Utilities Department, 1240 Sandpiper Lane, Atlantic Beach, FL 32233 in order that we can approve your application. If you have any questions, please call (904) 247-5834. Reviewed by D a Kaluzniak, Public Utilities Director Date a3 0 Signature Contractor Notified Date CITY OF ATLANTIC BEACH BUILDING !ZONING DEPARTMENT ~, Higgins 800 Seminole Road _~~~ Atlantic Beach, Florida 32233 (904)247-5800 (904)247-5845 Fax www.coab.us PLAN REVIEW COMMENTS Permit Application # ~~~~ /~~ Property Address: ~(Q ~~ ~ ri/ d- Applicant: ~~ I~ ~ Project: T,_h~is pe/rm~ it application bas been: ~' Approved ~. h ~/ ~ Reviewed and the following items need attention: Please re-submit y r plication when these items have been com feted. Reviewed By: Date: O3 ~L D~ Date Contractor Notified: CITY OF ATLANTIC REACH PUBLIC WORKS DEPARTMENT 1200 Sandpiper Lane Atlantic Bench, Florida 32233 ~) J (904) 247-5834 (/ p6~,+ (904) 247-5843 Fax www.coab.us PLAN REVIE`UV C®I~~INIENTS Permit Application # D~ - ~Zi~3 Property Address: ~ l0 3 ~N~,e,/ ~'r Applicant: IJH y ~' Project: (.U l1 h Q s Your application is approved as noted by the Public Works Department. Final application approval must come from the Building Department. ^ Your permit application has been reviewed by the Public Works Department and the following items need attention: C Please submit these requirements to the Public Works Department, 1200 Sandpiper Lane, Atlantic Beach, FL -32233 in order that we can approve your application. If you have any questions, please call (904) 247-5834. Reviewed by Carper; P.E., Public Works Director Date ~U- Signature Contractor Notified Date CITY OF ATLANTIC BEACH 8t10 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Application Number 06-00033112 Date 5/31/06 Property Address 363 AHERN ST Tenant nbr, name 1 CU 1 AHU Application description MECHANICAL ONLY Property Zoning TO BE UPDATED Application valuation 0 Owner Contractor ------------------------ ------------------------ DAVIE OCEAN STATE HEAT & AIR 363 AHERN STREET 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit MECHANICAL PERMIT Additional desc . Permit Fee 87.00 Plan Check Fee .00 Issue Date Valuation 0 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 87.00 87.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 87.00 87.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CIT1C OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING OFFICIAL ?,~ ~_~,~~ ,. ~7C J ~'/ `Jim CITY ~P ATLANTIC B~EAC~I 11~IECIIANICAL PENT APPLICATI®N „Date: ~-F'~ ' 4tll. Pro ert Address: ~ ~ / ~'~ S ~7( ~ ~L p y ~ Owner: ~ o ~+t~ I~~UI~~ Telephone #: p2 ~~-~0~~ Contractor~`~?Ct~„ ~i-~'t ~C~~i ~- 1~tj1`- Telephone #i~~~y~~~q'--'gyt~'! Contractor Address: l ~~ ~7~1~-8~c.x~/~-~' ..f~C~ • ~l • ~'ax #:(•~~Y o~~("~~~~~j' Contractor Signatur In consideration of permit g en for doinb des bed in the above statement, we hereby agree to perform said work in accordance with the attached plans and pecifications whi are a part hereo cordan ce with the`City of Atlantic Beach ordinances and standards of ood ractice listed therein. Type of Heating Fuel: If other construction is being done on this building or site, list the building permit number: Electric ^ Gas: _LP Natural _CentralUtility /tfl L..~3~ ~ ~3 ^ Oil (-/ V ^ Other - S eci MECHANICAL EQUIPMENT TO BE INSTALLED NATURE OF WORK Heat _ Space Recessed ' entral _ Floor ,~ Residential ~ Air Conditioning: _ Room ~ ~ --VCentral ~ ~ ^ Duct System: Material~~j~~~ Thickness~~t°~ ^ Commercial Maximum capacity / ~l60 cfm ^ Refrigeration -~ New Building ^ Cooling Tower: Capacity gPm ^ Existing Building ^ Fire Sprinklers: Number of Heads Manlift Escalator (Number) ^ Elevator: Replacement of Existing System _ _ ^ Gasoline Pumps (Number) ^ Tanks (Number) New Installation ^ LPG Containers (Number) (No system previously installed) ^ Unfired Pressure Vessel ^ Extension or Add-on to Existing System ^ Boilers ^ Gas Piping ^ Other -Specify ^ Other -Specify LIST ALL EQUIPMENT AIR CONDITIONING, REFRIGERATION EQUIPMENT & CONDENSOR'S Approving Number Units Description Model # Manufacturer Ton's Agency f ash ~3~a ~ ~~~~ ~ s ~ ~ HEATING -FURNACES, BOILERS, FIREPLACES & AIR HANDLER'S Approving Number Units Description Model # Manufacturer BTU's Agency ~ t~ ~ ~I~U~o~~ `~-- y~ oQV ~ ~ TANKS Nominal Capacity Type Liquid _. Senal _ .~pprovrng 'i„~ How Many & Dimensions Contained Manufacturer No. 1~: ~ rie~~'' ~~ 800 Seminole Road • Atlantic Beach, Florida 32233-5445 Phone: (904) 247-5800 • Fax: (904) 247-5845 • htto://www.ci.atlantic-beach.fl.us Revised 1/04 -~ , CITY OF ATLANTIC BEACH 800 SENHNOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5826 Application Number 06-00033327 Date 6/21/06 Property Address 363 AHERN ST Tenant nbr, name NEW SERVICE 200AMP/240V Application description ELECTRIC ONLY Property Zoning TO BE UPDATED Application valuation 0 Owner Contractor ------------------------ ------------------------ NELSON BROOKS & LIMBAUGH ELECTRIC CO 363 AHERN STREET 42 WEST 8TH STREET ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 241-9051 ---------------------------------------------------------------------------- Permit ELECTRICAL PERMIT Additional desc . Permit Fee 105.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 12/21/06 Fee summary Charged ----------------- ---------- Permit Fee Total 105.00 Plan Check Total .00 Grand Total 105.00 Paid Credited Due ---------- ---------- ---------- 105.00 .00 .00 .00 .00 .00 105.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. f~ ! :~,, ,.} ; FORM 600A-2004 Energ • auge® 4Q FLORIDA Et~ERGIi( EFFICIENCY CODE ~ FOR BUILDING COI~STI~UCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Via Mare Unit Four Address: Ahern St ~ ~~~~ City, State: Atlantic Beach, Fi Owner: Climate Zone: North Builder: Permitting Office: Permit Number: .furisdiction Number: ~ Atlantic Beach 261100 1. New construction or existing New - 12. Cooling systems 2. Single family or multi-family Single family ~ a. Central Unit Cap: 42.0 kBtu/hr _ 3. Number of wits, ifmulti-family 1 _ SEER: 12.00 - 4. Number of Bedrooms 2 ~ h. N/A - ~ 5. Is this a worst case? No _ _ 6. Conditioned floor area (ft') 1736 ftz c. N/A - 7. Glass typel and area: (Label regd. by 13-104.4.5 if not default) - a. U-factor: Description Area t3. Heating systems (or Single or Double DEFAULT) 7a. (Dble Default) 282.0 ft= ~ a. Electric Heat Pump Cap: 42.0 kBtu/!tr - b. SHGC: HSPF: 7.10 (or Clear or Tint DEFAULT) 7b. (Clear} 282.0 ft' __._ b. NIA - 8. Floor types - I a. Raised Wood, Stem Wall R-19.0, 36.Oftz _ c. N/A - b. N1A _- - c. N!A ~ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 50.0 gallons „ a. Frame, Wood, Exterior R=19.0, 1529.0 ft~ _ EF: 0.91 - b. Frame, Wood, Adjacent R=11.0, 378.0 ftZ ~ b. N!A .- c. N/A - - ' d. N/A - c. Conservation credits .,_. e. N/A _ (HR-Heat recovery, Solar 20. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0, 872.0 ftz 1S. HVAC credits ,_ h. N/A (CF-Ceiling fan, CV-Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup: Con. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft MZ-C-Multizone cooling, ` b. N/A MZ-H-Multizone heating) _~ Glass/Floor Area: 0.16 Total as-bu{{t points: 19764 PASS l Total base points: 25245 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. .-~ PREPARED BY: ~"~ DATE: 0 1 I hereby certify that this buildin , a designed, is in compliance with the Florida Energy de. OWNER/AGENT: ~ DATE: 1' 'b~ Review of the plans and specifications covered by this l DT " a ;`'~ ,,,~ ance calculation indicates comp y „ _ r,, with the Florida Energy Code. ~ 'a~~ "'~ 1~" ~`~~~~" Before construction is completed ~ this building will be inspected for compliance with Section 553.908 ~, Mo '~~ Florida Statutes. D wE BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. r_--....n _..-._~ n~..-_:.._. r~ nnnn ..~ n~ FORM 600A-2004 EnergyGauge® 4.0 SU1111I~IIER CALCULATIONS Residential Whole Building Performance Method A -Details ~ ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: ~ BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM =P oints Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF =Points .18 1736.0 20.04 6282.1 Double, Clear E 1.3 18.0 16.0 42.06 1.00 670.4 Double, Clear E 1.3 18.0 15.0 42.06 1.00 628.5 Double, Clear E 1.3 18.0 6.0 42.06 1.00 251.4 Double, Clear N 1.3 0.0 20.0 19.20 1.00 382.5 Double, Clear W 9.0 8.0 8.0 38.52 0.50 154.2 Double, Clear N 10.0 8.0 10.0 19.20 0.68 129.8 Double, Clear W 1.3 0.0 50.0 38.52 1.00 1919.7 Double, Clear S 1.3 8.0 13.0 35.87 0.95 442.1 Double, Clear W 1.3 8.0 4.0 38.52 0.97 149.9 Double, Clear E 1.3 8.0 16.0 42.06 0.97 654.1 Double, Clear N 10.0 8.0 24.0 19.20 0.68 311.4 Double, Clear N 10.0 8.0 10.0 19.20 0.68 129.8 Double, Clear E 10.0 8.0 24.0 42.06 0.46 467.5 Double, Clear N 1.3 8.0 7.0 19.20 0.98 131.3 Double, Clear W 1.3 8.0 50.0 38.52 0.97 1873.2 Double, Clear S 1.3 8.0 9.0 35.87 0.95 306.1 As-Built Total: 282.0 8602.0 WALL TYPES Area X BSPM =Points Type R-Value Area X SPM = Points Adjacent 378.0 0.70 264.6 Frame, Wood, Exterior 19.0 1529.0 0.90 1376.1 Exterior 1529.0 1.70 2599.3 Frame, Wood, Adjacent 11.0 378.0 0.70 264.6 Base Total: 1907.0 2863.9 As-Built Total: 1907.0 1640.7 DOOR TYPES Area. X BSPM =Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 52.0 6.10 317.2 Exterior 52.0 6.10 317.2 Base Total: 52.0 317.2 As-Built Total: 52.0 317.2 CEILING TYPES Area X BSPM =Points Type R-Value Area X SPM X SCM = Points Under Attic 872.0 1.73 1508.6 Under Attic 30.0 872.0 1.73 X 1.00 1508.6 Base Total: 872.0 1508.6 As-Built Total: 872.0 1508.6 FLOOR TYPES Area X BSPM =Points Type R-Value Area X SPM = Points Slab 0.0(p) 0.0 0.0 Raised Wood, Stem WaII 19.0 36.0 -1.50 -54.0 Raised 36.0 -3.99 -143.6 Base Total: -143.6 As-Built Total: 38.0 -54.0 FORM 600A-2004 EnergyGauge® 4.0 SUfWII~IER CALCULATIOwS Residential Whole Building Performance Method A -Details ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: BASE AS-BUILT INFILTRATION Area X BSPM =Points Area X SPM = Points 1736.0 10.21 17724.6 1736.0 10.21 17724.6 Summer Base Points: 28532.7 Summer As-Built Points: 29739.0 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System -Points) (DM x DSM x AHU) (sys 1: Central Unit 42000 btuh ,SEER/EFF(12.0) Ducts:Con(S),Con(R),Int(AH),R6.0(INS) 29739 1.00 (1.00 x 1.147 x 0.86) 0.284 1.000 8387.1 28532.7 0.4266 12172.0 29739.0 1.00 0.992 0.284 1.000 8387.1 FORM 600A-2004 EnergyGauge® 4.0 1NINTER CALCULATIONS Residential Whole Building Performance Method A -Details ~ ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: ~ BASE AB-BUILT GLASS TYPES .18 X Conditioned XBWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area XWPM X WOF =Point .18 1736. 0 12.74 3981.0 Double, Clear E 1.3 18.0 .16.0 18.79 1.00 302.0 Double, Clear E 1.3 18.0 15.0 18.79 1.00 283.2 Double, Clear E 1.3 18.0 6.0 18.79 1.00 113.3 Double, Clear N 1.3 0.0 20.0 24.58 1.00 491.5 Double, Clear W 9.0 8.0 8.0 20.73 1.18 195.7 Double, Clear N 10.0 8.0 10.0 24.58 1.02 250.9 Double, Clear W 1.3 0.0 50.0 20.73 1.00 1037.5 Double, Clear S 1.3 8.0 13.0 13.30 1.02 176.4 Double, Clear W 1.3 8.0 4.0 20.73 1.01 83.5 Double, Clear E 1.3 8.0 16.0 18.79 1.01 305.2 Double, Clear N 10.0 8.0 24.0 24.58 1.02 602.3 Double, Clear N 10.0 8.0 10.0 24.58 1.02 250.9 Double, Clear E 10.0 8.0 24.0 18.79 1.35 607.9 Double, Clear N 1.3 8.0 7.0 24.58 1.00 172.1 Double, Clear W 1.3 8.0 50.0 20.73 1.01 1044.0 Double, Clear S 1.3 8.0 9.0 13.30 1.02 122.1 As-Built Total: 282.0 6038.7 WALL TYPES Area X BWPM =Points Type R-Value Area X WPM = Points Adjacent 378.0 3.60 1360.8 Frame, Wood, Exterior 19.0 1529.0 2.20 3363.8 Exterior 1529.0 3.70 5657.3 Frame, Wood, Adjacent 11.0 378.0 3.60 1360.8 Base Total: 1907.0 7018.1 As-Built Total: 1907.0 4724.8 DOOR TYPES Area X BWPM =Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior Wood 52.0 12.30 639.6 Exterior 52.0 12.30 639.6 Base Total: 52.0 639.6 As-Built Total: 52.0 639.6 CEILING TYPES Area X BWPM =Points Type R-Value Area XWPM X WC M = Points Under Attic 872.0 2.05 1787.6 Under Attic 30.0 872.0 2.05 X 1.00 1787.6 Base Total: 872.0 1787.6 As-Built Total: 872.0 1787.6 FLOOR TYPES Area X BWPM =Points Type R-Value Area X WPM = Points Slab Raised 0.0(p) 36.0 0.0 0.96 0.0 34.6 Raised Wood, Stem Wall 19.0 36.0 0.80 28.8 Base Total: 34.6 As-Built Total: 36.0 28,g FORM 600A-2004 EnergyGauge®4.0 1I~tNTER .CALCULATIONS Residential Whole Building Performance Method A -Details ~ ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: ~ BASE AS-BUILT INFILTRATION Area X BWPM =Points Area X WPM = Points 1736.0 -0.59 -1024.2 1736.0 -0.59 -1024.2 Winter Base Points: 12436.6 Winter As-Built Points: 12195.0 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System -Points) {DM x DSM x AHU) (sys 1: Electric Heat Pump 42000 btuh ,EFF(7.1)Ducts:Con(S),Con(R),Int(AH),R6.0 12195.0 1.000 (1.000 x 1.169 x 0.88) 0.480 1.000 6049.2 92436.6 0.6274 7802.7 12195.0 1.00 1.033 0.480 1.000 6049.2 FORM 600A-2004 EnergyGauge~ 4.0 WATER HEATI~fG & CODE COI~IIPLIAI~CE STATUS Residential Whole Building PerFo~mance Method A -Details ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit =Total Bedrooms Volume Bedrooms Ratio Multiplier 2 2635.00 5270.0 50.0 0.91 2 1.00 2663.96 1.00 5327.9 As-Built Total: 532'7.9 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 12172 7$03 5270 25245 8387 8049 5328 19764 PASS ~y°4~,~ Sx,~,~o~. E`• NHr '•~. : fir, ~~`a~ d * ~o FORM 600A-2004 EnergyGauge® 4.0 Code Compliance Checl~list Residential Whole Building Performance Method A -Details ~ ADDRESS: Ahern St, Atlantic Beach, FI, PERMIT #: I 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. "'~ Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; ., foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility \ penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss orjoint members. EXCEPTION; Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1 /2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from ~ conditioned space, tested. Multi-story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. ~ Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, ~ have combustion air. OH-LL V A r1CK 1"1'CCS~.KIF' 1 IVC 11nGR5UKC5 (nIUSL De islet Or eXCeedeCl by all reSldenCeS.) COMP NENTS SECTION -- REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir `1 breaker (electric) or cu#off (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. \ Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSTG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. ~ Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. ~ Common ceiling & floors R-11. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 86.4 The higher the score, the more efficient the home. Ahern St, Atlantic Beach, FI, 1. New construction or existing New _ 2. Single family or multi-family Single family _ 3. Number of units, ifmulti-family 1 _ 4. Number of Bedrooms 2 _ 5. is this a worst case? No _ 6. Conditioned floor area (ft2) 1736 frz 7. Glass types and area: (Label regd. _ by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a. (Dble Default) 282.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (Cleaz•) 282.0 ft~ 8. Floor types a. Raised Wood, Stem Wall R=19.0, 36.Oft= _ b. N/A _ c. N/A _ 9. Wall types a. Frame, Wood, Exterior R=19.0, 1.529.0 ft' _ b. Frame, Wood, Adjacent R=11.0, 378.0 ft= _ c. N/A _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 872.0 ft2 _ b. N/A _ c. N/A _ 11 . Ducts a. Sup: Con. Ret: Con. AH(Sealed) :lnterior Sup. R=6.0, 175.0 ft _ b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b: N/A c. N/A 14. Hot water systems a..Electric Resistance b. N/A Cap: 42.0 kBtu/hr _ SEER: 12.00 c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV-Cross ventilation, HF-Whole house fan, PT-Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: Cap: 42.0 kBtu/hr _ HSPF: 7.10 Cap: 50.0 gallons _ EF: 0.91 _ /~4~xH sr,~~,~ ~~ ~~ ti~ r~~~~ *NOTE: The home's estimated energy performance score i.s only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar'~"'designation), your home may qual~.for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www, fsec. ucf. edu for information and a list of certified Raters. For information about Florida`s Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass out ut on ages 2&4. $nergyGauge® (Version.: FT~,RCSpB v4.0) RIGHT-J BUILDING ANAL~(SIS REPORT Entire House Energy Design Systems Job: 10112/05 1065 Oak Vale Rd, Jacksonville, FI 32259 Phone: 904287-5339 Fax: 904-287-1258 Email: energydesignsystems~gmatl.com i ~ ?ft i For: Unit Four Via Mare Ahern St, Atlantic Beach, FI i. s ~ ,~,, Htg Ctg Infiltration Outside db ~°F) 39 92 Method Simplified Inside db (°) 72 72 Construction quality Average Design TD {°F) 33 20 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 65 Component Btuh/ftz Btuh % of load Walls 2.0 3402 12.8 Windows 23.9 6747 25.4 Doors 15.2 789 3.0 Ceilings 1.1 1059 4.0 Floors 23.2 6123 23.0 Infiltration 22.7 7577 28.5 Ducts 878 3.3 Total 26575 100.0 uw~,org._ ~C?ta~l~l~ Component Btuh/ftz Btuh % of load Walls 1.7 2845 10.0 Windows 56.0 15801 55.5 Doors 12.7 660 2.3 Ceilings 1.6 1540 5.4 Floors 0.0 0 0.0 Infiltration 6.9 2296 8.1 Ducts 1732 6.1 Internal gains 3600 12.6 Total 28474 100.0 ~°a~ Cooling at 84 %SHR = 2.8 ton Cooling air flow = 494 cfm/ton Cooling at 70 %SHR = 3.3 ton Cooling at 400 cfm/ton = 3.4 ton Overall U-Value = 0.167 Btuh/ftz-°F Data entries checked. ,~. wr~ghtsoft Right-Suite ResidentialTM 5.0.66 RSR29784 2005-Oct-13 10:12:14 ~(, C:1Documents artd Settings\customer\My Documents\Wrightsoft\Via Mare Unit FOUR Ahem St Atl Bch.rsr Page 1 RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire blouse Energy Design Systems Job: 10/12/05 1065 Oak Vale Rd, Jacksonville, FI 32259 Phona: 904-287-5339 Fax: 904-287-1258 Email: energydestgnsystems~gmail.com r ~ ~ • i?: For: Unit Four Via Mare Ahern St, Atlantic Beach, FI Notes: ®~SI n ~I~~OrI"1D~$Ifkn Weather: Jacksonville, Mayport Naval, FL , US Winter Design Conditions Summer Design Conditions Outside db 39 °F Inside db 72 °F Design TD 33 °F Heating Summary Building heat loss 26575 Btuh Ventilation air 0 cfm Ventilation air loss 0 Btuh Design heat load 26575 Btuh Infiltration Outside db 92 °F Inside db 72 °F Design TD 20 °F Daily range L Relative humidity 50 Moisture difference 65 gr/Ib Sensible Cooling Equipment Load Sizing Structure 28474 Btuh Ventilation 0 Btuh Design temperature swing 3.0 °F Use mfg. data n Rate/swing multiplier 0.97 Total sens. equip. load 27619 Btuh Method Simplified Construction quality Average Fireplaces 0 ~ Heating Cooling Area (ft ) 1736 1736 Volume (fta) 15624 15624 Air changes/hour 0.80 0.40 Equiv. AVF (cfm) 209 104 Heating Equi pment Summary Make Trade Latent Cooling Equipment Load Sizing Internal gains 920 Btuh Ventilation 0 Btuh Infiltration 4579 Btuh Total latent equip. load 5499 Btuh Total equipment load 33119 Btuh Cooling Equipment Summary Make Trade Efficiency 0.0 HSPF Efficiency 0.0 EER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Heating temp rise 0 °F Total cooling 0 Btuh Actual heating fan 1362 cfm Actual cooling fan 1362 cfm Heating air flow factor 0.051 cfm/Btuh Cooling air flow factor 0.048 cfm/Btuh Space thermostat Load sensible heat ratio 84 Printout certified by ACCA to meet atl requirements of Manual J 7th Ed. :. wr~ghtsofit Right-Suite ResidentlalTM 5.0.66 RSR29784 2005-Oa-13 10:12:14 .~~ C;~Documents and SettingslcustomerlMy DocumentslWrigMsoftlVia Mare Unlt FOUR Ahem St Atl Bch.rsr Page 1 - `'"s :~ ~, rS~~f r~~,, CITY OF ATLANTIC BEACH ELECTRICAL PERMIT APPLICATION ~ i : _ 1 Date• Properly Address: _~6 ~ ~~~~ ~ Y~~ Owner: Telephone #~~~ ~1-~~ Contractor: ~S m ~ Telephone #~ 4-C1C~ Contractor Address: ~ Faz #: ~~-}Q- Contractor Si store: In consideration of permit given -for doing work described in the above statement, we hereby agree to perform said work in accordance with the attached plans and specifications which are a part hereof and in accordance with the City of Atlantic Beach ordinance and standards of ood ractice listed therein. Bu' -ng: New ^ Old ^ Re-wire lding Type: D Trailer 1~ Residence ^ Temp. / ^\ Commercial ^ Si ~ ^ Addition Sq. Ft. a ice: New ~InCrease ^ Repair if other construction is being done on this buildmg Or site, list the building Permit u ber O6- ~~-/ ~ 3 Conductor Size: S: COPPER ALLTMINLTM Switch or Breaker AMPS PH W VOLT RACE WAY Eaisting Service Size AMPS PH W VOLT RACE WAY Meter Number Feeders: NO. SIZE NO SIZE NO SIZE Lighting Outlets CONCEALED OPEN Rece tacles CONCEALED OPEN Switches Incandescent Fluorescent & M.V. ' Fixed o.l0o atoms OVER BELL A fiances TRANSFER Air Conditionin H.P.RATING COMP. MOTOR H.P. RATING OTHER MOTORS AMPS CEILING HEAT KW-HEAT Motors 0-1 H.P. VOLTAGE PH NO. OVER 1 H.P. PHS UNDER600V OVER600V Transformers NO. KVA NO. KVA No.Neon Ttansf. Ea- Si Miscellaneous a ~. L.~Y1 t 4- 800 Seminole Road • Atlantic Beach, Florida 32233-5445 Phone: (904) 247-5800 • Fag: (904).247-5845 • http://~nvw.ci.atlantic-beach.tl.us Revised 1/04 CI'~"Y' ®~' ATLANTIC ~~ACH PUBLIC W®RKS Y)EPARTNIFjNT 1200 Sandpiper Lane ~~ Atlantic Beach, Florida 32233 (904)247-5834 (904) 247-5843 Fax www.coah.us ~LA1~ i D~ d~~ C®1'i~Al~'$A'i1,T~ i~er~nit Application # Q ~ ~ ~ Z l ~ 3 Property Address: ~ l0 ~ ~H~,e ~ ~'r Applicant: ~A V I Project: C,U n ~ 0 .S Your application is approved as noted by the Public Works Department. l~ final application approval must come frown the Building Department. x ^ Your permit application has been reviewed by the Public Works Department and the following items need attention: Please submit these requirements to the Public Works Department, 1200 Sandpiper Lane, Atlantic Beach, FL -32233 in order that we can approve your application. if you have any questions, please call (904) 247-5834. Reviewed by Carper; P.E., Public Works Director Date ~U S1gI18tUTe Contractor Notified Date