Permits 725 Atlantic Blvd #9 CITY OFATLANTIC BEACH
jz1
800 SEMINOLE ROAD
J �
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
��r1 i3l>r
Application Number . . . 06-00034497 Date 2/12/07
Property Address . . . . . . 725 ATLANTIC BLVD UNIT 09
Application type description COMMERCIAL INTERIOR BUILD OUT
Property Zoning . . . . . . . TO BE UPDATED
Application valuation 15000
------- ----------- --- -- --- --- ---------- ----------
Application desc
INTERIOR BUILD-OUT/MELLISSA' S PIZZA
----------- -- -- - -- -- - -- - --- ------- ---- -------
Owner Contractor
-------------- -- -------- --- --- -- - --------- ------
ALAN DICKENSON R. S . PENNINGTON CONSTRUCTION
166 N. HIGHWAY STE. 100-B 380 13TH AVE N
PONTE VEDRA BCH FL 32082 JAX BEACH FL 32250
(904) 993-2000
-------- - -------- -- -------------------------
Permit BUILDING PERMIT
Additional desc . .
Permit Fee . . . . 105 . 00 Plan Check Fee 52 . 50
Issue Date 1/25/07 Valuation . . 15000
Expiration Date . . 8/06/07
------------------------ --- ------- -----------
Special Notes and Comments
2500 GALLON GREASE INTERCEPTOR TO BE
INSTALLED PRIOR TO FINAL PLUMBING
-------------------- ------
Fee summary Charged Paid Credited Due
- - --------- --- ------- - ---------
Permit Fee Total 105 . 00 105 . 00 . 00 . 00
Plan Check Total 52 . 50 52 . 50 . 00 . 00
Grand Total 157 . 50 157 . 50 . 00 . 00
00
1
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
■
■ ,-i r1��j�.
■ �� J�:� CITY OF ATLANTIC BEACH
a
F/Ji311f"
■ 800 SEMINOLE ROAD
ATLANTIC BEACH,FLORIDA 32233-5445
■ Telephone: (904)247-5826
■ Fax: (904)247-5845
Email: sgraham@coab.us
FAX
To: il.�! GL.._� Fax#
From: Date: 119 Q
Pages: Re:
El Urgent For Review Please Reply
Notes:
Gt/ ca--
C
yl
James R. McCue & Associif s' .'Inc: `
AR11214
�: �
Architects ' ���� 1 �'0 0�� MLI
Commercial, Residential Architecture&Architectural Counseling
January 19, 2007
To: David Hufstetler, Chief Building Official 800 Seminole Road Atlantic Beach, Florida 32233
Re: Research to determine the adequacy of the 3,000 gallon grease interceptor installed
In"North Beach Center", on Atlantic Boulevard for(4) four restaurants.
(Having to do with the permit for"Malissa's Pizza")
Dear David :
With the help of the building owners maintenance firm, we have researched the capacity and
adequacy of this interceptor. Enclosed, please find the following:
1. A letter from"A-1 Waste Management, Inc., the firm servicing the grease
Interceptor.
I suggest you examine the second paragraph of this letter and in cooperation with
the Owner set up a servicing cycle which will insure the future performance of
this system.
Since the calculations demonstrate the inadequacy of the system, perhaps a meeting
including the following: owners representative;yourself; a utilities representative;
and a representative of"A-1 Waste Management" and Sean Akoglan at the site
might help to resolve this matter. If necessary, the tank could be exposed and its
capacity discussed. The meeting might result in a letter from the Owner changing
the servicing cycle from 90 to 60 days,with a report to be furnished by"A-1"
after each service call to show how the system is functioning. This monitoring may
result in a shortened service cycle or whatever may be indicated by the facts.
2. A specification with drawing depicting the unit installed from `Standard Precast, Inc.
3. The calculations prepared by the Owners management firm demonstrating the
adequacy of the existing Grease Interceptor for all four restaurants in the center.
David, I hope this will help in resolving this issue and Mr. Akoglan can move forward with his
new restaurant as soon as possible
I will fax you a copy and send a hard copy with the next mail.
Thanks for your help in resolving this matter. If I can be of further help,please call.
Sin?,,,,' es
;- ��
4
R. McCue, Architect
2804 St. Johns Bluff Road South, Jacksonville Beach, Florida 32246
Tel: (904) 646-2777 Fax: (904) 646-2778 E-mail: mccarch@bellsouth.net
Grease Interceptor Calculations-
Usage Calculation—
Seating capacity x 25 gallons ( for China) =gallons required
Gallons required x 1.0 (Main road Load factor) - .25%= final capacity required
Malissa's Pizza-
Hours of operation— 10= .83
Seating capacity- 72 persons
China settings—25 gallons
72 x 25 = 1800 gallons ; 1,800 x .83 = 1,494 gallons
1,494 x 1.0 - 25%= 1,120.5 gallons required
Tree Steak house-
Hours of operation—5 = .42
Seating capacity— 150 persons
China settings- 25 gallons
150 x 25 = 3,750 gallons ; 3,750 x .42= 1,575 gallons
1,575 x 1.0 - 25%= 1,181.25 gallons required
Po Boys-
Hours of operation— 10= .83
Seating capacity— 197 persons
Plastic/paper settings— 10 gallons
197 x 10= 1,970 gallons ; 1,970 x .83 = 1,635 gallons
1,635 x 1.0 - 25%= 1226.32 gallons required
Tijuana Flats-
Hours of operation— 10
Seating capacity—70 persons
Plastic/paper settings— 10 gallons
70 x 10=700 gallons ; 700 x .83 = 581 gallons
581 x 1.0—25%= 435.75 gallons required
1,120.5 + 1,181.25 +1,226.32 +435.75 = 3,964 total gallons required
3,000/ 3,964= 75.68% of capacfty provided= 24.32% deficiency calculated
2804 St. Johns bluff Road South, Jacksonville Beach, Florida 32246
Tel: (904) 646-2777 Fax: (904) 646-2778E-mail: mccarch@bellsouth.net
JHN-1(-�104�( 10:10H FRUM:MELISSH'S PIZZR 9042417775 T0:6462778 r•1'
Awl waste macnagement! l`nce.
7300 imeson Road
Jacksonville, Florida 32219
904-78&8700 Shane®A1wastemgmt.com 904-788-6722 fax
January 26, 2006
Bob Huffman
Preferred Property Management Systems
166 N. Dickinson Commercial
Ponte Vedra Beach, Fl.
32082-5701
Re: Grease Trap at North Beach Center
Mr. Huffman
We have been servicing the 3000 gallon grease interceptor located at North Beach
Center(725 Atlantic Blvd,Atlantic Beach, FI, 32233) once every 90 days for approximately
18 months. During this time'period the level of solids in the trap has consistently been in the
neighborhood of 26%of the total volume of the tank. In my experience, as long as the total
solids volume does not exceed 40%-50%the total volume of the Interceptor it will continue
to function normally.
I believe if the pump out frequency were reduced to 60 days this tan could handle another
restaurant with no problem. My suggestion would be for us to try that and adjust tha
frequency so that the solids content does not exceed 25%. As we do in the JEA's F.O.G.
program In Jacksonville.
Your business is most appreciated and we look forward to handling this matter for you.
Thank you
Shane Thomas
*w A nri:, r;,'P'refierred Hauler*
JHN-JL(-EIOW( 10:11H FRUM:MELISSR'S PIZZA 9042417775 T0:6462778 P.3/5
"Standard for Quality"
CARL W. F07ERSON 11340 PMILLIP$MIQNWAV + F.0. BOX 73007 i JACKAOHVILL6. FLORIDA 3!241-3007 au/•alOFOAaI
CHAIRMAN
Pt e0Tif93-0401
61AA4APA L. ►ITI}SON PAX 904-260-"03
rR65JOiNT
DATE: APRIL 14, 2003
roN=AcvoR: SOUTHERN DEVELOPMENT, INC.
PRO.I CP: NORTH BEACH CENTER
TO WHOM IT MAY CONCERN:
THIS LETTER IS TO CERTIFY THAT ANY AND ALL PRECAST REINFORCED CONCRETE MANHOLE
SECTIONS,INLETS,CATCH BASINS, WE I"WELLS,ETC,,MANUF'AGTUR.1 D BY STANDARD PRECAST,
INC.,MEET AND I OR EXCEED THE STANDARD SPECIFICATIONS AS DESIGNATED BY THE
AMERICAN SOC.FTY OF TESTING ANO MATERIALS(ASTM)AS FOLLOWS:
FOR CIRCULAR STItUCTURM C-478
FOR RECTANGULAR STMICTURES. C-890 AND C-913
FOR I3UX w Lv het I S: C•789 OR C-830
IN ADDITION TO MEETING ASTM SPECIFICATIONS. WE FURTHER CERTIFY THAT OUR PRF,.CAST
CONCRETE PRODUCTS MEET AND / OR EXCEED•ALL CITY Of JACKSONVILLE, FLORIDA
SPECIFICATIONS AND ALL FLORIDA DEPAR'T'MENT OF TRANSPORTATION SPECIFICATIONS.
SINCERELY,
/z0ba=
STANSTAN11WO PRECAST,INC.
PRODUCTION REPRESENTATIVE
SWUFiN AND SUBSCRI9FI7 To,BEFORE Me,THIS 147". DAY OF APRIL 2003.
ONE
�ort� "y°OIIAJ Wm�a ARY PI ®LTC
r1•11■ MYMMYM .4~1
F+CS4 rOrdcACfC"010Eg
Of•rLWC1r �-1C
6AN1tART AND ITORM•EW111 ItRUOTURII . • . 46'THOU 4/-WETWILLS • IOx 0WIRTf • IRICuI ELCV44AK rRNNOLEI • 8NC141 iTXMR
vo/E9 3Jdd 83G"lInS SI680H 11003 E689ELZO96 9S:01 190Z/60/T0
Unit i� wcrr 4c+•11n I I�Ui 1.1 IGL_1JJn J [-iLLn 7CIZC'7111 IJ IU.O`fOCf lCS I'.C+J
�.i V f,.i fi V,L.i+1►�``1 W M W���� 'moi Q Yt�i�W moi/p ��•vr'r
''S►nnderd for Quality,,
CaPI W. PfiYERSUN
CHAIRMAN 11340 PHILLIPS MIONWAY / P 0 BOX 23607 / JACKSONVILLE,FLOPIOA 22141.3p07 00+tbb0�6p
FL/04�P�W611
iAAOe;IIA L ►C7050AI
►114510CNf PAX 804.0664103
DATE: AP7!!. 14; 2003
CONTRACTOR: SOUTHERN AEVEL.Opmf r, INC.:.
PROJECT: N081'H H A.CH CENTER
SUBMITTALS ON: PRKASI" �TRIICTlIRES
DESIGNED BY: LINDA L. Deu"L' EUETTG
NOTES:
auaac• MAM�q MlMplp
• t �. / �:SIP F41� wIL�,�X It.tY
CON145C RS A'd"W'r
iANlTatpt AItlC i1f.71fM G[WBp U'pYC TYFLS..-.-�•® tt"fNpU 1+t"WpTW6�:8 0
408 CULYlp1 S�• +♦ '• WL(irk,Q,I,f,'r/11CA•$l1iYl4.F11 ' •••• `• „~ ULIfew_-
7'-'A%-?r.0r:= ;r, A7 1T
JHIV-1 f-ClJkO f 1U:11H I-KUIl-VItLlbbH 5 h'1L1-H yb4t41((f5 TU:6462778 P.4/5
ti
10 t m
� R�7
to
W v7 Q M N
R7
ai
In
N14a
m 'm Im
av, w0x
CL td s
W a w
VI
x
u - . V! .: o
w a cti E• a,
4 4 e a
• A , 4 e a
12.+
(0 L
a P"cy . 0
i ?
co
11
06/08 39dd m3mins siaww 110:)5 Z689�tLG66 9S Ol' [POc:�'66/tB
7
Awl D
-p
Ids 554ERA-t,
TiAY5 oo-T ci�,- F
t You
A, W-lefl�)6r 1
1 4oPs `t0i1 W t t t
5f4o Avoa-qwTo
C.OH , :m U1oR� 4N l-�S
E
S
HP Oflicejet 7410 Log for
Personal Printer/Fax/Copier/Scanner Information Systems
904-247-5845
Jan 19 2007 4:39PM
Last Transaction
Date Time Type Identification Duration Panes Result
Jan 19 4:36PM Fax Sent 92475843 2:40 8 OK
James R. McCue & Associates. Inc.
AR11214
Architects JAN )1061,
Commercial, Residential Architecture&Architectural Counseling
January 19, 2007
To: David Hufstetler, Chief Building Official 800 Seminole Road Atlantic Beach, Florida 32233
Re: Research to determine the adequacy of the 3,000 gallon grease interceptor installed
In"North Beach Center", on Atlantic Boulevard for(4) four restaurants.
(Having to do with the permit for"Malissa's Pizza")
Dear David :
With the help of the building owners maintenance firm, we have researched the capacity and
adequacy of this interceptor. Enclosed,please find the following:
1. A letter from"A-1 Waste Management, Inc., the firm servicing the grease
Interceptor.
I suggest you examine the second paragraph of this letter and in cooperation with
the Owner set up a servicing cycle which will insure the future performance of
this system.
Since the calculations demonstrate the inadequacy of the system,perhaps a meeting
including the following: owners representative; yourself, a utilities representative;
and a representative of"A-1 Waste Management" and Sean Akoglan at the site
might help to resolve this matter. If necessary, the tank could be exposed and its
capacity discussed. The meeting might result in a letter from the Owner changing
the servicing cycle from 90 to 60 days, with a report to be furnished by"A-1"
after each service call to show how the system is functioning. This monitoring may
result in a shortened service cycle or whatever may be indicated by the facts.
2. A specification with drawing depicting the unit installed from `Standard Precast, Inc.
3. The calculations prepared by the Owners management firm demonstrating the
adequacy of the existing Grease Interceptor for all four restaurants in the center.
David, I hope this will help in resolving this issue and Mr. Akoglan can move forward with his
new restaurant as soon as possible
I will fax you a copy and send a hard copy with the next mail.
Thanks for your help in resolving this matter. If I can be of further help,please call.
Sin?Jes*R.
A 4��
McCue, Architect
FILL VA-1PI
2804 St. Johns Bluff Road South,Jacksonville Beach, Florida 32246
Tel: (904) 646-2777 Fax: (904) 646-2778 E-mail: mccarch@bellsouth.net
Grease Interceptor Calculations-
Usage Calculation—
Seating capacity x 25 gallons ( for China) =gallons required
Gallons required x 1.0 (Main road Load factor) - .25% =final capacity required
Malissa's Pizza-
Hours of operation— 10= .83
Seating capacity- 72 persons
China settings—25 gallons
72 x 25 = 1800 gallons ; 1,800 x .83 = 1,494 gallons
1,494 x 1.0 - 25%= 1,120.5 gallons required
Tree Steak house-
Hours of operation—5 = .42
Seating capacity— 150 persons
China settings-25 gallons
150 x 25 = 3,750 gallons ; 3,750 x .42 = 1,575 gallons
1,575 x 1.0 - 25%= 1,181.25 gallons required
Po Boys-
Hours of operation— 10= .83
Seating capacity— 197 persons
Plastic/paper settings— 10 gallons
197 x 10= 1,970 gallons ; 1,970 x .83 = 1,635 gallons
1,635 x 1.0 -25%= 1,226.32 gallons required
Tijuana Flats-
Hours of operation— 10
Seating capacity—70 persons
Plastic/paper settings— 10 gallons
70 x 10= 700 gallons ; 700 x .83 = 581 gallons
581 x 1.0—25%= 435.75 gallons required
1,120.5 + 1,181.25 + 1,226.32 +435.75 = 3,964 total gallons required
3,000/3,964= 75.68% of capacity provided= 24.32% deficiency calculated
2804 St. Johns bluff Road South, Jacksonville Beach, Florida 32246
Tel: (904) 646-2777 Fax: (904) 646-2778E-mail: mccarch@bellsouth.net
lb:IUH hKUM:MEL155H'S HIZZH 9042417775 70:6462778
P.1/5
Waste Management Inc..
7300 imeson Road
Jacksonville, Florida 32219
904-786-6700 Shane@A1wastsmgmt.com 604-786-6722 fax
January 26, 2006
Bob Huffman
Preferred Property Management Systems
166 N. Dickinson Commercial
Ponte Vedre Beach, Fl.
32082-5701
Re: Grease Trap at North Beach Center
Mr. Huffman
We have been servicing the 3000 gallon grease interceptor located at North Beach
Center(725 Atlantic Blvd,Atlantic Beach, FI, 32233) once every 90 days for approximately
18 months. During this time'period the level of solids in the trap has consistently been in the
neighborhood of 26% of the total volume of the tank. In my experience, as long as the total
solids volume does not exceed 40%-50%the total volume of the interceptor it will continue
to function normally.
I believe if the pump out frequency were reduced to 60 days this tan could handle another
restaurant with no problem. My suggestion would be for us to try that and adjust the
frequency so that the solids content does not exceed 26%. As we do in the JEA's F.O.G.
program In Jacksonville.
Your busineas is most appreciated and we look forward to handling this matter for you.
Thank you
Shane Thomas
**A1:_.-,_''.Preferred Hauler**
11,:11H FHUM:MELISSH'S PIZZA 9042417775 T0:6462778 i
"Standard for Quality" �•
GA>tl W. t'1TBRSOM
CHAIRMAN 11340/NIWP$N10NW4V � P. 0. MOX 13607 i�ALKAOIFV161.i. 9604104 72Ta1g0pf OIM•�O►OA00
R 4013170304"
YAAYAPA L.PITIVION
P49slocwr Iwl 904.2"440
DATE: APRIL 14, 2003
co?vMCTOR: SOUTHERN DEVELOPMENT, INC.
PttOJFCT: NORTH BEACH CENTER
TO WHOM IT MAO'CONCERN:
THIS LETTER IS TO CERTIFY THAT ANY AND ALL PRECAST REINFORCED CONCRETE MANHOLE
SECTIONS,INLETS,CATCH BASINS, WE['WELLS,ETC.,MANUFACTURED BY STANDARD PReCA3T,
INC..MEET AND/OR EXCEED THE STANDARD SPECIFICATIONS AS DESIGNATED BY THE
AMERICAN SOC'.ETY OF TESTING AND MATERIALS(ASTM)AS FOLLOWS:
FOR CIRCULAR STRUCTURES: C-078
FOR RECTANGULAR vmucTJREB: C•890 AND C•913
FOK UUX(.0 LV ttt f S: C•789 OR C•810
IN ADDITION TO MEETING ASTM SPECIFICATIONS. WE FURTHER CERTIFY THAT OUR PRECAST
CONCRETE PRODUCTS MEET AND i OR EXCEED•ALL CITY OF JACKSONVILLE, FLORIDA
SPECIFICATIONS AND ALL FLORIDA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS.
SINCERELY,
S AN PRECAST,INC.
PRODUCTION ROPMENTATIVE
SWUKN AND SUDSCRIBED TO,BEFORE M8,THIS 147". DAV OF APRIL 2001.
UFO ow
vo hr IIw4ft
v/l
O►tt '"'oaM�slloMpigmt i 'SI
wMDTARY PLUTAILIC
♦Ir1 ■ MMMMM
. . e.• p Cs 4NAIGNK U q-IRs
_` ...�+�. ... rL0AC1• --m rGJ164crowi ARIi(1G
CAMIA1lY AN6 lT6r1M LIVrm armucTullls • '"•— �••���3•• �'-�"•-•-.+..._
ar bleu,a•wtl'V I LILA low C111,0103 VlCul lUC1MOK r
...�^.....�---•...-...._-..,....—tom.... --+-�•�-�...... .� ... .��•��.�. uwOL!• • 7r1lULItRMtI
VO/EO 3JCJd kl3QlIflfl SITIa(]Vv .LLOaS �689EtT,b06 99:0t L00i;/b0/t0
�111A.11A
. ••'�+ �i��-i..>✓n ✓ r 1LLn 7YJ'TL'Yl I 1 i J
Iv.040Cr10 r•.C,J
3 GiL�L�����::/�`e� � Gi" ���7�Li� ti 0 ���i0 ir•...�t4
''S►nnderd Iar 011o1i�y" �b�,,,.
CARL W. Fillenson
CHAIRMAN 11340 PHILLIPS NFONWAY / P q BOX 13807 J JACIf30NVILLe,FLOPIOA 72241.7107 00•46&odso
YARBAAA L PiTEfISON FLM3034MBI
►RiS10[Ni PAX WN-41111118-4403
C"Oht�.RIE11TE STORM SY141.1-11C."TURES
DATE: AP?!(. 14, 2003
CONTRACTOR: SO(JTHE:RN DEYh'I.Olmoct, wc-
PROJECT: N081'H NEA.t,H U.'NTER
SUBMITTALS ON: PWAST STRW:TURES
DESIGNED BY: LINDA L. DeBL' IEUETTG
NOTES:
raraca N1►�fr•Q M[Mff11
{ANIi•N•AML aramm ssvxu LY/YCTu"s • w reap 4,.1•w"Wfl:[ • 1A[CUIYfM I•_••_ _•• ••►.►••- ••••. .••►_. .-..�+��.�.
... .�� fi6Gn�i,!C'b11C.1a fa•sil4.p •• GC1Al�1 tlV:
UQ:TQ 70141.1 ll�f1'jT c,YII;Ihai 1 !ITIw
:car./6G1/Tp
'nil -CVJU iq:11H rKU is NtL1b5H 5 Y'14LH J04d41 r r r5 VU:6462778
P.4/5
W
Z w '''
AMW
`R 19 AM11 OOOiii
AG il► Q .ems C49
eK
m1% C49
1
F,, � w • oa
�u g
.o
� a
3
W 0 3
xr K> 1
Q
Of
O A
.• dy .o o
Jo
Cc
to
b8/b0 3�Vd 83cnife si, 110:iS L699LtZFrBE 9G:01 [E0Zl6BlT.B
\;S6 CITY OF ATLANTIC BEACH
800 SEINIINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5826
Application Number . . . . . 07-00000039 Date 2/02/07
Property Address . . . . . . 725 ATLANTIC BLVD UNIT 09
Application type description PLUMBING ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
installation of 1500 gal . grease-trap
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
NORTH BEACH CENTER DOUG'S DRAINS & MORE, INC.
PENMAN PROPERTIES LLC. 2453 BAYWAY CT
725 ATLANTIC BLVD UNITS 1-21 ATLANTIC BEACH FL 32233
ATLANTIC BEACH FL 32233 (904) 71-0172
----------------------------------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . .
Permit Fee . . . . 42 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 8/01/07
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 42 . 00 42 . 00 . 00 . 00
Plan Check Total . 00 .00 .00 . 00
Grand Total 42 . 00 42 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
rS�yLyr,� CITY OF ATLANTIC BEACH
PLUMBING PERMIT APPLICATION
Date:
rconntractor:
Address: !!sb /�..F M�� 7)3—
Ad
f L� G Telephone#•
Owner:
,tABee Telephone#:
Fag#or Address: Z�< 3 36' "J ��
i--4�2 —
Contractor Signature:
,cations which are a Part hereof and in accordance with the City of Atlantic Beach
In consideration of permit given for doing the work as described in the above statement,we hereby agree to perform said work m
accordance with the attached plans and specific
ordinance and standards of good practice listed therein.
Installation of plumbing and fixtures must be in accordance with the most recent edition of the Southern Standard Plumbing
Code.
If other construction is being done on this building or site,
Plumbing Type: New list the building permit number:
❑ Re-Pipe
Number of Fixtures:
Bath Tubs Showers
Closets Shower Pans
_ Dishwashers — Sinks
_ Disposals
Urinals
_ Floor Drains
Washing Machine
_
Water
Lavatory
Water Heaters
Sewer
/Sao ��/,
Sprinkler System 5'e�sf T, Other*See attached sheet see
For Backflow and irrigation procedures
Fees
Permit Issuing Fee: $35.00
Total Fixtures: �_ X$7.00 + $35.00=
800 Seminole Road -Atlantic Beach, Florida 32233-5445
Phone: (904) 247-5800- Fax: (904) 247-5845- http:ltwww.ci.atiantic-beach.f��evised 9106