Permit HVAC 1085 Atlantic Blvd 92 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001204 Date 9/12/12
Property Address . . . . . . 1085 ATLANTIC BLVD 92
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
1085 ATLANTIC LLC RUNNELS AIR CONDITIONING
5118 N 56TH ST 4222 CINDY RD
TAMPA FL 33610 LAKELAND FL 33810
(863) 581-4268
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/11/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: io ERmnr#
PROJECTVALUE $ ARI# 14 -7 OCC 2,-7
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratinp-
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit Vz-
Heat: Unit Quantity I BTU's Per Unit K LL) Seer Rating I e)
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work-does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name 9 Id Phone Number
-?-,u ti n-p-(-s /1. 4 —
Mechanical Company C1,,tA i T I-Vtl 1/14&4iCZA�-icje PhonZ63----' -
Co. Address: 4Z -g, 0-,;,,L1ij 14\102r4 City LaLjeAgL*.,tjj, State f-I Zip tn
t
License Holder(Print): t %--rrLj 16,-Rann-ed-S State Certitfi, n/Registration#U-W 4,1160
Notarized Signature of License Holder
]�o
- ----------
r
L.GRAHAKb
y of/ 20
Wo and sub;�Wed befo
jarj 14
f.111 1�b,�rUnd 'R U
ir" , �',;: ,
14,2014
Y."blic U 64 R re of Notary Public ZI-L
Mpr 7.,
IMP an*17GERT TM
L— www.ahridirecl ry.otg 'A
Certificate of Product Ratings
AHRI Certified Reference Number: 4700027 Date: 9/10/2012
Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit
Outdoor Unit Model Number: GSX1 30301 D*
Indoor Unit Model Number:AR*F303016C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(13tuh): 28400
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a VAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(i;)listed on this Certificate and makes no representation$,warranties or guarantees as to,and assumes no respionsiblillity for,
the product(s)listed on this Cortiftate.AHRI oxpressly disclaim all liability for dismages of any kind wising out of the use or performance of the product(s),or do
unauthorized alteration of dab usted on this Certificate.Certified!ratings am valid or*for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This cemcate and its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidlential reference purposes.
The contents of this Certificate may not,in whole or in par%be reproduced;copied,disseminated;entered Into a computer database;or otherwise utflb*d,In any
form or manner or by any means,except for the usees individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The hvkxma*m for the model eked on this cortiftate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating,
click on"Verify Certificate"Kink and~the AHRI Cerffled Reference Number and the dab on &OW an ILI and Refrigeration Institute
which the certificste was Issued,which is Noted above,and the Certifkate No.,which Is Rated below.
02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 1299177674%898595
DesignStar Load Calculation
Results are in-tendedfbrusewith Rheem heating and cooling systems only
Tne Nm Degm at comfon-
ig
U
4X�
Atla�ntic blyd' F L 52
..........
e
'e :�303.375.;G"'�613681,6*-
L
70
. ............
...........
L
..........
e-
us Ware E 4 0 ft
0 Poo 95
�s
-erry unne .s�
ame. :
N T: 'R I
7
h A
P
4
Email. terunsrPaol.,corn.
. ........ ........ ....... -------- ..............
'House Information
SHR .75,
7-7 77777777777-7-7:,
77-
U
Ceiling�height 8
................................
7-7 7�77-�7777-
ue
Wa
Lv
Floor U-value R-value 0.2 5
777*7�--� 7-7-777 7777 -777-77-7 .................
777777-777777-
n. U
U
C ue
............ ..........
Window U-value
7777 7777-7.7 -,-7777.77-
7 77T
Amn SK.5f
Moisture grains 0.85
7 7 777777.777---
7777 777
D
Duct gain % 10
777 7-7 7- 77-
U
C;
qqRn.,g.IpT
........ .........
.............
Heating infiltration (ACH) 0.8
7 -7- - -77777,77
7.777777 777
Summer ventilation 0
�,Desiqn Conditions
Outdoor Heating Cooling
----------
'Dr 93
Y YU0
................... .............. ............
Daily range M
�7 ...........777-77777-77-
Relative: :qrp 5 0 X,
.......... ..................... ................... ...........
Moisture difference 53
.............. ..................... ................................ .......................... ................. .......................................................
Indoor Heating Cooling
................ 77
or re
In'do m 7
pers t.
............
Design temperature differenceff) 38 18
........................ .............. .............................................-....................... .......................... ........................................................... ..........
Load
Area 13tuh % of load
3
: 9,
Floor 30.9
............ ---------------
'191 &2 1.
3
.e Ing,
Hi
'Windows
6080 26
�n
j,6"9:,
System Efficiency ss, :2125 9.1:
Heating Loads
23,370 BTU/hr
Ceiling
Wall
Floor
System Efficienc)
Infiltration
windows
Z
-&2
A i
Vo
.............
Walt 492:!:,. �4
"M
M
p-
�-44-,;�,;
gg,
""RNN A
4,
R
"Q MAW
M
MM
5
NOW.
40.2
-2 S 41.7
Uitent:Pe
oO,
V,
11,7"7-7
..........
Cool i ng Loads
25,034 BTU/hr
Sensible P ople Load
e
Latent People Load
Ceiling
Wall
Internal
Sensible Infiltratiod
System Efficlenc',
Windows
Latent Infiltration I
'Adequate Exposure Diversity
---------------
AED Graph
30000
20000
q
10000
0
8am 9am 10am 11am 12prn 1PM 2pm 3pm 4pm 5pm 6pm 7pm 8PM
Hourly Loads Average
'ACCA Manual S
System equipment selection will be made using the following Manual S derived values.
Summer Outdoor 930F
-7...............-t-77--`7
urnmer,�
Summer Indoor 750F
................. 777—
raiq�
�.estdp,G_
Winter Outdoor 32"F
7 �777*7-77-
7-7 7-77".7
77
nt
,W
....................
Sensible Cooling 22,050 Btuh
..........r----------7.,-�-1.,�."�---=-,7--.-�------- ..........
16tbnt�C66 n
,a
t..� .......011---- .......................... �m m ............
Required Cooling Airflow 1,002 CFIVI
-------77717
0 B-tuh,
s0hstbje Higattri
Required.Heaing Airflow 304 CFM
----------.................. ................ ...................
...........
All.calculations are based Upon.6 0 d edUres�and comply with all local
Porov. d hVac in ustry standards and proc
state andjederal,code requirements.All.cbrnputed r4s�lts are Estimates'.Productprovided by Energy DeSlgq:
Systems�and Idea tree.