Permit HVAC 1085 Atlantic Blvd 93 2012 st CITY OF ATLANTIC BEAC H" 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001205 Date 9/12/12 Property Address . . . . . . 1085 ATLANTIC BLVD 93 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/11/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI, CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. C?-r MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: :��FERMIT# PROJECTVALUE $ ARI# -7 C)CC) 2:-7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTUs Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit ')- V7-- Heat: Unit Quantity BTU's Per Unit 5 K LJ Seer Rating---La!-- Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certif�that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of an),other state or local law regulation construction or the performance of construction, Property Owners Name X V S " Phone Number A �( t �, - �fak t #1C -- -&:�, —$�-77 Mechanical Company ALL ti n�o-CS kt-Cz*-Lj�' t B-Aic/e Pbonc%3-' Co. Address: 4ZZ%, L,1kL1LJ r='A City LaLj�,o-� - - StateF/ Zip,3�etn License Holder(Pr -Runttel-S State Ccjtification/Registration#U 4� 60 int 7�— r q )6, Notarized Signature of License Holder::2:Z�2,� Zzf-�- - G�A worn emet da-y­8`f1 ,;HIRLE�L.G RAHAM and sub-scribed be e me is 20 j CTr q 50 57T ignat lic EXPIRES'FPbltlai'y 14,2014 T Bonde�d Thl;tiOta',y Public�Inde-rite" ure of Notary Pu lic A 4— r.Ll � U c N., I A E117 www.abridirectory.org A Cerstiticate of Product Ratip,gs AHRI Certified Reference Number: 4700027 Date: 9/1012012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number:AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28400 EER Rating(Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published date,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(*)Rated on this Cerdficsts and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)Rated on this Cortifluft.AHRI expressly discialmis all liability for damages of any kind arising out of the use or performance of the product(*),or the unauthorized afteration of data Rated an this Cerdflc4ft.Certified ratings are valid only for models and configmations Rated In the directory at www.aliridirectory.org. TERMS AND CONDITIONS This Certificate and He contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes. The contents of this Cefdfw4ft may not In whole or In part,be reproduced;copied;disserridnated;entered Into a conVuter database;or otherwise ullitzed,In any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the modell cited on this cartificate can be verified at www.ahridirectory.org, "IMP, Air-Conditioning,Heating, efick on"Verify Certificate"Unk and enter the AHRI Certified Reference Nurrdw and the data on Now no ILI and Refrigeration Institute which the certificate was Issued,which is Rated above,and the Certificate No.,which is Rated below. 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 esignStar Load Calculation suits are intended fbr use with Rheem heating and cooling systems only T"Nm DeWw ol OmWT4 0 EP g I"A Nzxilr 'ILI In UQJJ 0 'Z ........ U-4 1'6i� �c` ..............I.................................... REM= S Pei z" C. V j223 �bl%d bUML -A Street Ad L 4-4 30 e S Hous F quprg,�oq, 95, age, Nam.e.::z,,... nels:, 581 426 Email: terunsr(apaol.com ---------- -------- ---------------- iHouse Information SHR .75 :Ii N *d f ......... Ceiling height 7777 7 ':'7 7 7�77 7 77 Ue Wall V� L 9 .......... ................ ........... Floor U-value R-value 0.2 5 77 -7-7-7`77777 -7�7, 7-77 -77777� 7 ----------- n U .......... Window U-value ....... 7� 7�7'7 7777......�77� 77.77.7-7 7-7"7�77'!77'1.�'.'�'�---":77�'7"-�7.,'�'----7!'�-"'?-7�- 77!77 7 77, W d 'S G �V' ........... ............. Moisture grains 0.85 7 �77-7.77-'-7 - -------- `77'77�--'-77-, Duct gain % 10 77777 77-7-7777777-- -77 77!:-�77�77.�!-77,--�,-!-7777�777-�'�-,.-�� 77 ACH -q� I :J.,nf I trAttio Heating infiltration (ACH) 0.8 - t7 r777.-7'�777�'.�,,---'-'���'7'r-�-� 7 7�� -7 7777-77, 77-777 '�77 `777777777 7 .n atj t -777 �777 P;er: Summer ventilation 0 D Re "Design Conditions ------- Outdoor Heating cooling 32 :: 93: y bulb (�,F), .......... .......... ......... ................ Daily range M .......... ................. t Rela -d- loy Y, .................. .......... ....... ........... Moisture difference 53 ..................... .............................. ..................................... ........................ -..-................................................................ ........... Indoor Heating Cooling I door.t u n ............ .............. Design temperature differenceff) 38 18 ............................................................... ........... ............ ......................... ................. ............... Heatinq Loads Area Btuh 9/6 of load w Floor 72,20 30.91 1 ................ ......... . .....11, 8.2 Windows 0801 ., 26 i6A! - 9A S m,,Eff yste _p��pn(� Lpss�� Heating Loads 23,370 BTU/hr Ceiling Wall Floor Affl., System Efficienci Infiltration Windows �ggg M, v 4 z -0 1 n Win aws., av a MINE, Rig 1E I -10. 1`110111 R ME HE k7a J" eiltept thfifte, tf6h- fat6ir"h4f 10'66 !!I i RON X� 21'..MUS 11,11 FINE, L a e e 4�4 nt ........... �z 4v LaitdritAbad 7 .ons:. �k%J:5j, H, 4, T ity 5 Cool i ng Loads 25,034 BTU/hr SensiblePe IeLoad op Latent People Load Ceiling Wall Internal Sensible Infiltrati o6 System Efficlencj Windows 0 Latent Infiltration I 'Adequate Exp osure Diversity AED Graph 30000 20000 V 3 10000 0 8am 9am 10am 11am 12pm IPM 2pm 3pm 4pm 5pm 6pm 7pm 8PM -Z, C—::�HoudyL..�ds ::A�-,.ge ACCA Manual S System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F 7-777-7 b S Mer e - W t UT .......... .......... .......... Summer Indoor 75 cF --------------- 77-7--l-7:-77 5 D G �a Winter Outdoor 32"F 7777 W .1n d 7VF�� Sensible Cooling 22,050 Btuh 2 i984, Btu Required Cooling Airflow 1,002 CFIVI .......... 7 ---7-77-7 L 6 H, S:. s b! Required Heaing Airflow 804 CFIVI ........... All calcuhtions,are based upon appro-ved hvac inclustrystanclards and procedures,a, hd cor.nply with all local, state and federal coderequirernents.All.cbmpubE�d results are Estimates,Pirodti�tprovidecl 6 E Design y nergy Systems and Idea Tree..