Permit HVAC 1085 Atlantic Blvd 90 2012
CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD N� ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 'sem Jii SA Application Number . . . . . 12-00001412 Date 10/02/12 Property Address . . . . . . 1085 ATLANTIC BLVD 90 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/31/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 / / Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: © A T`Lllo_ tg int- —6( &0�'LZ I�/ ERMIT# PROJECT VALUE $ 71Z. 7 Z , s 1 ARI# N 7 000 2--7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit )- %1z- Heat: Unit Quantity---I BTU's Per Unit S K LJ Seer Rating 13 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Q. ^a ry►eS Phone Number Mechanical Company un neCs r' 0<' 161' �ttice Phon(E o3 $r_ ax 463=77'T-9"Tc�, Co. Address: 47,Z A, 0-,,1'k4Q :RC=gA City 6LRX4 State F Zip License Holder (Print): r n eLs State Ce ' cation/Registration#C41-,p 4/-//60 Notarized Signature of License Hold S Mao gibe before me is d yo 2012- °�: d? EXPIRCS:Febru����4,2014 Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ��' The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on &I" on -' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 Desi nStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tie Now Qcgroe of Com'ort"J iCustomer Information Location: Street Address 108BAtiantic blvd, DUVAL, FL_ 32233 Latitude; Longitude 30.3375°, -81.7686° Fiou-,se Square Footage: 1050 sq. ft. Name: Terry Runnels Phone; 863-581-4268 Email: tert.insr@aoi.com t House • • SHR .75 .......................................... . ........................._..... .. . ................ .__..........._. . ......................_ ......... ... ..........................._ Number of residents 4 ...... Ceiling height 8 _............... ....._.................... ...... .. ... ....................__......_.. .. _._._................. . .... _ ..... ._... . . ....__ ._ Wall U-value R-value 0.09 11 Floor U-value R-value 0.2 15 Ceiling U-value I R-value 0.05 19 Window U-value 1 _........................._.............__............_.........__........._....._.._.._._.... ------................_................._.._..._........._................. .._._......................... ...... Window SHGF 0.85 .. ...... . Moisture grains 0.85 .....-_ . ..._._ ......... _ ._.._ ................. _... ............ . .......... .................................................... _. _.... _.. Duct loss % 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 ,Heating infiltration (ACH) 0.8 :Winter ventilation : 0 Surnmer ventilation 0 i Design Conditions Outdoor Heating Cooling Dry bulb (°F) 32 0-3 Daily range M 777,777 Relabve hurl'iditly 50% Moisture difference 53 ......................................................_..................................................................................................................................._........................................................................._.................................................... ................_ Indoor Heating Cooling ..._ .. .. ............_ ....._.... ..... .... ...._.... _ .. ._...... _ ..............._.. _ _............ Indoor temperature (°F) 70 75 Design temperature difference(OF) 38 18 I i I i I Heating Loads Area Btuh % of load Wali 2201 M Floor 7980 31.9 Ceiling 2115� ` ` Windows 0080 24.� � ` ` Infiltration � 4354 I7.4 ` ' ----- System EffcieUo Loss� 2273 9.1 .........................._...._'... ................ -- Total: 25002 Head ng Loads 25,002 BTU/hr Ceiling Wall Floor KA System Efficienc� Infiltration Windows Cooling • • Area Btuh % of load Wall 1042 4 ening 1002 3.9 Windows 15150 v8.6 Sensible infiltration 1547 Latent Infiltration 2815 10.9 System Effic ;cv,,! Gain 1` 8.3 ll,tern4l x_178 41 Sensible People Load4 .9 ..-.. Latent People Load 483 1.9 Total: 25856 Sensible load 22553 Latent load 3298 SHR 0.87 Capacity at .75 SHR 2.51 Tolls Cooling Loads 25,856 BTU/hr Sensible People Load Latent People Load `--Ceiling F l— Wall s Internal Sensible Infiltratior System Efficient, Windows J Latent Infiltration Adegu.ate Exposure AED Graph 30000 20000 0 ..r 10000 0 8am gam loam Ilam 12pm ipm 2pm 3pm 4pm Spm 6pm 7pm 8pm �- Hourly Loads_-Average 'ACCA' System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93°F .-..........................._......................--......_........_....._..............__...................................................-.........................._..__............._......................................__................... ................................_........... Summer Wet Bulb 77°F Summer Indoor 75°F _... .... Summer Design Grains 50% ....... ............_......_..._..... Winter Outdoor 32°F .._.._............._.........__.....__.................__................._....._....__....................._.._......._._._..._..._.........................._._._..._................_.................._...._........................ Winter Indoor 70°F Sensible Cooling 22,558 Btuh Latent Cooling 71 3,298 Btuh Required Cooling Airflow 1,025 CFM .... _... ._.._. _....__. Sensible Heating 25,002 Btuh _..... .. ... _. .._..... ...._... . ._._... _._.:._ Required Heaing Airflow 325 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree